c1fb5c05-26b0-4cf5-a477-34d86dbf9e01.pdf
PDF 73 KB Posted
- Attached to
- Cross Gallery Southwest Annex Refresh Project
- Solicitation number
- ISD-371462-RO
About this file
This document is a detailed architectural design guide from Fermilab ISD-Engineering for a single exterior hollow metal door (HW-1) with fire rating specifications. The guide specifies a 3'-0" x 7'-0" x 1-3/4" galvanized steel door manufactured by Steelcraft or an approved equal, with a UL-labeled fire-rated core using vertical steel stiffeners or laminated mineral board. The door features an entrance function that can be unlocked by a key from the outside and is always unlocked from the inside.
The specification includes comprehensive hardware requirements such as 1-1/2 pair of McKinley hinges with non-removable pins, a Best lockset with entrance function, a Von Duprin panic hardware set, a Norton closer, Zero weather-stripping, a Pemko door bottom sweep, a Hager drip cap, a Rockwood flush bolt, a Zero threshold, an optional Ives kick-plate, and various door stop options. A special note indicates that cylinders will use interchangeable core, small format, 7-pin tumbler inserts, with Fermilab responsible for final cores and keys after the construction period.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISD Engineering – Architectural General Section 3.0
Fermilab ISD-Engineering Design Guides Page 2 of 13
WARNING: This manual is subject to change. The current version is maintained on FESS Section website. Rev. 1, 08/2025
Hollow Metal Door – Single Exterior (HW-1)
1 HOUR FIRE RATED – 45 MINUTE LABEL
2 HOUR FIRE RATED – 90 MINUTE LABEL
Single Door – 3’-0” x 7’-0” x 1-3/4”
Use galvanized steel door and frame
Fire rated door with UL label
Manufactured by Steelcraft or approved equal.
Fire-rated core: manufacturer's standard vertical steel stiffener and/or laminated mineral board core for fire-rated doors.
Entrance function – unlocked by turning key outside, always unlocked from the inside
Item Description Comments
Hinges 1-1/2 Pair Hinges
Manufacturer: Mckinley Or Equal
Model: TA2714 4.5 X 4.5
Options: Non-Removable Pin
Finish: Satin Stainless
Product Number: 652
If door is higher than 7 ‘ or wider than 3’ look into the use of additional hinges or larger hinges.
Steel Base, Ball-Bearing Type.
Provide 1 Hinge For Every 30 ” Of
Door Height.
Lockset 1 Ea. (Function: Entrance)
Manufacturer: Best 93K7AB15D / S3 / 626 *
This is not panic hardware. If building occupancy requires see panic hardware set
Panic Hardware 1 set- Von Duprin 35a-F Rim Fire Exit Device series panic device with rods.
Finish to be 628 anodized aluminum.
Lever to be Von Duprin 360L.
Closer 1 Ea. 3. NORTON 7500 SERIES
Finish to be 689.
Pull or push side jamb mounting depending on the swing of the door.
Weather-stripping 1 Set - Zero #314AA. At exterior door
Door Bottom
Sweep
1 Ea. –
Manufacturer: Pemko Or Equal
Model Number: 18061CNB
At exterior door
Drip Cap 1 Ea.- Hager. At exterior door
ISD Engineering – Architectural General Section 3.0
Fermilab ISD-Engineering Design Guides Page 3 of 13
WARNING: This manual is subject to change. The current version is maintained on FESS Section website. Rev. 1, 08/2025
Item Description Comments
Flush Bolt Manufacturer: Rockwood
Model: 2842/2942
Product number: 630
Automatic flush bolts: ANSI/BHMA
A156.3, type 25, grade 1; minimum
3/4- inch (19-mm) throw; with dust-proof strikes; designed for mortising into door edge. Include wear plates.
Thresholds 1 Ea.- Zero #545A.
Finish Anodized Aluminum
Set threshold for doors in full be of sealant
Kick-plate
(if desired)
Ives .050 Stainless Steel Beveled 4 Sides with
Countersunk Screws. 10” High x Width of Door
Less 2”.
Door Stop 1 Ea. – Floor Stop – Ives FS13 Dome Stop US
26D for use without threshold or
Ives FS17 Dome Stop for use without threshold or
1 Ea. – Wall stop – Ives WS402CCV US 26D or
1 Ea. – Plunger –Ives FS1154 US 26D
Select one type of stop
* Cylinders: Equip locks with cylinders for interchangeable core, small format, 7 pin tumbler inserts. Furnish only temporary inserts for the construction period, and remove these when directed. Final cores and keys for installation will be Fermilab's responsibility.