This document is an Evaluation of Qualifications Form for Integrated Project Delivery (IPD) issued by the State of Colorado Office of the State Architect, State Buildings Program, for the Montrose Indoor Firing Range Lead Dust Mitigation project (Number 082411). The form serves as the standardized evaluation tool for assessing construction manager/general contractor (CM/GC) qualifications and proposals. The evaluation framework does not specify response deadlines, due dates, site visits, bidders' meetings, or award dates within this document, as it functions as an internal evaluation instrument rather than a solicitation notice. The contract term and renewal options are not defined in this form.
The evaluation methodology employs a weighted scoring system combining qualifications (60% weight) and fee proposals (40% weight), with evaluation scores from multiple evaluators (up to six) averaged to determine final rankings. Qualifications are assessed across six categories: firm qualifications and organizational structure; management team member qualifications and location access; project management approach including cost and schedule effectiveness; prior project experience with three reference projects; equity, diversity, and inclusion practices; and miscellaneous factors such as claims history and apprenticeship programs. Each criterion receives a rating from 0 (not provided) to 5 (excellent), with total qualification scores converted to a maximum of 40 points. Proposal scoring awards a maximum of 60 points to the lowest-fee bidder, with other proposals scored proportionally. The state establishes a minimum passing score percentage prior to evaluation, and firms must demonstrate acknowledgement and attestation of minimum requirements to be considered eligible for evaluation.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Appendix C Montrose Lead Specification 2024.pdf | ||
| ADDENDUM 1.pdf | ||
| SC8.1 DB LS GC_2026.pdf | ||
| SBP6.18 Labor Burden Calc R8-2023.docx | DOCX document | |
| SC8.0 DBLS A_2026_1.pdf | ||
| Signin Sheets 11-5-26.pdf | ||
| 082411 Montrose IFR RFP.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
IPD-GMP-App-A (R1)
STATE OF COLORADO
OFFICE OF THE STATE ARCHITECT
STATE BUILDINGS PROGRAM
APPENDIX A: EVALUATION OF QUALIFICATIONS FORM:
INTEGRATED PROJECT DELIVERY
Name of Firm:____________________________________________________________________ Name of Project: 082411 Montrose Indoor Firing Range Lead Dust Mitigation Evaluator No:_______________________________________ Date:______________________________________________
RFP REFERENCE MINIMUM REQUIREMENTS Y ____ N ____
ACKNOWLEDGEMENT AND ATTESTATION INCLUDED: Y ____ N ____
If the minimum requirements have not been met, specify the reason(s):
INSTRUCTIONS:
1. Weights are to be assigned prior to evaluation and are to be consistent on all evaluation forms.
2. Use only whole numbers.
3. Rating: 0 = not provided, 1 = Unacceptable, 2 = Poor, 3 = Fair, 4 = Good, 5 = Excellent
4. Total score includes the sum total of all criteria.
5. A passing score (as a percentage of the total points available) is to be established by the state prior to evaluation.
1. QUALIFICATIONS OF THE FIRM(S) Weight X Rating = Score ◻ Overall qualifications x = ◻ Organizational structure/lines of authority X = ◻ Subcontractor selection and management X ◻ Colorado workforce X ◻ Safety/employee support X
2. QUALIFICATIONS OF MANAGEMENT TEAM MEMBERS Weight X Rating = Score
◻ Qualifications and relevant experience of superintendent X =
◻ Qualifications and relevant experience of in-house staff X
◻ Location/Access
3. PROJECT MANAGEMENT APPROACH Weight X Rating = Score ◻ Approach to successful CM/GC Services
Cost Effectiveness X = Schedule effectiveness X
Quality effectiveness X ◻ Competitively Bid/Self Performed Work
4. PRIOR PROJECT EXPERIENCE/SUCCESS Weight X Rating = Score ◻ Project #1 X =
Timeliness Disruption Budget Considerations Quality Acceptability/Punchlist Compliance
◻ Project #2 X = Timeliness Disruption Budget Considerations Quality Acceptability/Punchlist Compliance
◻ Project #3 X = Timeliness Disruption Budget Considerations Quality Acceptability/Punchlist Compliance
5. EQUITY, DIVERSITY AND INCLUSION Weight X Rating = Score
◻ Hiring and Promotion Practices X = ◻ Subcontracting Practices X =
6. MISCELLANEOUS Weight X Rating = Score
◻ Claims/litigation history X = ◻ Apprenticeship Training Program X = ◻ Other X =
Total Score: _________
STATE BUILDINGS PROGRAM
APPENDIX A1: EVALUATION OF QUALIFICATIONS FORM:
INTEGRATED PROJECT DELIVERY
Name of Firm:____________________________________________________________________ Name of Project: 082411 Montrose Indoor Firing Range Lead Dust Mitigation Evaluator No:_______________________________________ Date:______________________________________________
INSTRUCTIONS:
1. Weights are to be assigned prior to evaluation and are to be consistent on all evaluation forms.
2. Use only whole numbers.
3. Rating: 0 = not provided, 1 = Unacceptable, 2 = Poor, 3 = Fair, 4 = Good, 5 = Excellent
4. Total score includes the sum total of all criteria.
5. A passing score (as a percentage of the total points available) is to be established by the state prior to evaluation.
1. QUALIFICATIONS OF THE FIRM(S) Weight
Rating
Score x =
2. QUALIFICATIONS OF MANAGEMENT TEAM
MEMBERS
X =
3. PROJECT MANAGEMENT APPROACH
4. PRIOR PROJECT EXPERIENCE/SUCCESS
5. EQUITY, DIVERSITY AND INCLUSION
6. MISCELLANEOUS
Total Score: _________
STATE BUILDINGS PROGRAM
APPENDIX A2: QUALIFICATIONS AND PROPOSAL RANKING
MATRIX: INTEGRATED PROJECT DELIVERY
INSTRUCTIONS/EXAMPLE:
1. QUALIFICATIONS Example uses the 60% / Fee 40% split.
2. Insert total score from each evaluator's SUBMITTAL review.
3. Add all evaluators’ total scores and divide by the number of evaluators to determine the average score for each firm’s qualifications.
4. The maximum score for qualifications on the evaluation form is equivalent to 40 points and is equivalent to the maximum points available for qualifications. Therefore, each firm’s score is determined as a percentage of the maximum points available. To score each average qualification score, use the example formula.
5. Assume the highest score is 600.
SCORING OF QUALIFICATIONS
FIRM B: 600 X 40 points = 40 points
FIRM C: 500 X 40 points = 33.33 points
FIRM A: 400 X 40 points = 26.66 points
6. Determine score for each firm’s sealed proposal with the lowest fee being equivalent to a maximum score of 60 points. To score each proposal, use the example formula.
7. Assume the lowest Proposal was $100,000.
SCORING OF PROPOSALS
FIRM A: $100,000 X 60 points = 60 points $100,000
FIRM B: $100,000 X 60 points = 48 points $125,000
FIRM C: $100,000 X 60 points = 39.99 points $150,000
8. Add the average qualification score to the Proposal score to determine cumulative qualifications and fee score.
9. Numerically rank all firms with the highest scoring firm being the most qualified and advantageous to the state.
FIRM
QUALIFICATIONS
AVE.
QUALS
SCORE
PROPOS
AL
PROPO
SAL
RANK
EVAL
#1
EVA
L #2
EVA
L #3
EVA
L #4
EVA
L #5
EVA
L #6
File details come from the government source that posted it. Updated .