IFB_250103_Ochoa_Plan_Set.pdf
PDF 13 MB Posted
- Attached to
- Jacobs Park & Ochoa Soccer Complex Improvements
- Solicitation number
- 250103
- Issued by
- Pima County, Tucson City, Arizona
About this file
This is a development plan set for Ochoa Park improvements prepared by the City of Tucson Parks and Recreation Capital Planning & Development Unit, located at 3300 North Fairview Street in Tucson, Arizona. The project encompasses comprehensive improvements to the Ochoa Soccer Complex, including upgrades to three soccer fields with new LED lighting infrastructure, irrigation system replacements with turf rotors and drip emitters, new tree plantings with associated landscaping, concrete replacements, post and cable fencing, and a renovated walking path with added trees and drip irrigation. The plan set includes detailed construction documents showing site plans, grading plans, utility plans, landscape and hardscape plans, irrigation plans, and specifications organized across multiple sheets. The project references a project number TD-DEV-1223-00487 with design progression dated from 30% conceptual design (March 3, 2023) through 75% design (July 10, 2023) to 100% construction documents (December 15, 2023), with an issued for construction set date of December 20, 2024.
The scope of work is structured with a base bid and ten additional alternates (#1-2, #5, and #8-10 specific to Ochoa Park, with alternates #3-4, #6-7 designated for Jacobs Park). Key alternates include LED lighting upgrades for Fields 1 and 2, post and cable fencing installation at the soccer complex, and turf rotor replacements for Fields 1, 2, and 3. The project mandates compliance with the Build America Buy America Act, requiring contractors to understand and comply with federal procurement regulations for materials. The plan includes detailed irrigation specifications using Class A+ reclaimed water with purple-identified piping, drip emitters rated at 2 gallons per hour, and rotor sprinklers with Hunter equipment (I-40-04-SSR models with 46', 55', and 57' spray radius options). Landscaping includes 5 Texas Ebony and 23 Leslie Roy Mesquite trees at 15-gallon size, with 2,564 square feet of new concrete paving and approximately 298,243 square feet of turf restoration using Hydrostolon Tiftuf Bermuda hybrid grass. The contract requires a one-year warranty on plant material, irrigation systems, and workmanship, with all work coordinated through the City of Tucson Project Manager prior to construction initiation.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEVELOPMENT PACKAGE
OCHOA PARK
CITY OF TUCSON
3300 N. FAIRVIEW STREET
PRINCE RD
MIRACLE MILE
RODGER RD
FA
IR
VI
EW
A
VE
N F
AI
R
VI
EW
A
VE
IMPROVEMENTS
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\S
HE
ET
S
IF
C\
8- C1
.0_
CO
VE
R_
2-
IF
C.
DW
G
PL
OT
TE
D:
/20 /20
:16 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
100% CD03.07.24
IFC SET12.20.24
(2) EXISTING 2" RECLAIMED
WATER METERS TO REMAIN
IN PLACE. COORDINATE WITH
COT PM PRIOR TO WORK.
PB
PBPB
PB
PB
PB
PB PB PB
PB
PB
15 15 15 151515
08 08
08 08
08 08
15 15
151515
08 08
15 15 15 15
N O
R T
H F
A
IR
V
IE
W A
V E
N U
E
N O
R T
H F
A
IR
V
IE
W A
V E
N U
E
PR
OP
ER
TY
LI
NE
PR
OP
ER
TY
LI
NE
PROPERTY LINE
PR
OP
ER
TY
LI
NE
PR
OP
ER
TY
LI
NE
PROPERTY LINE
NORTH
FIELD 3 UPGRADED LIGHTING TO LED AND UPGRADED INFRASTRUCTURE FOR FIELD 1 AND 2.
CONTRACTOR SHALL INSTALL LED LIGHTING PER ELECTRICAL PLANS. ALL ELECTRICAL OUTAGES AND HOOK UP REQUIREMENTS
SHALL BE COORDINATED WITH THE CITY OF TUCSON.
C1.0A
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
ADDITIONAL ALTERNATES
PLAN
ADD ALTERNATE OVERVIEW
SCALE: 1" = 50'
ADDITIONAL ALTERNATIVE #1
N
FA
IR
VI
EW
FIELD 1 AND 2 UPGRADED LIGHTING TO LED
CONTRACTOR SHALL INSTALL LED LIGHTING PER ELECTRICAL PLANS. ALL ELECTRICAL OUTAGES AND HOOK UP REQUIREMENTS
SHALL BE COORDINATED WITH THE CITY OF TUCSON.
ADDITIONAL ALTERNATIVE #2
OCHOA SOCCER COMPLEX - INSTALL POST AND CABLE FENCING PER THE CONSTRUCTION DOCUMENTS POST AND CABLE FENCE SHALL BE INSTALLED BY CONTRACTOR PER PLANS AT THE LOCATIONS SHOWN ON THE PLAN.
ADDITIONAL ALTERNATIVE #5
OCHOA SOCCER COMPLEX - FIELD 1 NEW IRRIGATION TURF ROTORS
CONTRACTOR SHALL REMOVE AND RETURN EXISTING TURF ROTORS TO CITY OF TUCSON PM. CONTRACTOR SHALL INSTALL NEW ROTORS AND SWING ARM ASSEMBLIES PER THE PLAN AND MANUFACTURER RECOMMENDATIONS.
ADDITIONAL ALTERNATIVE #8
OCHOA SOCCER COMPLEX - FIELD 2 NEW IRRIGATION TURF ROTORS
CONTRACTOR SHALL REMOVE AND RETURN EXISTING TURF ROTORS TO CITY OF TUCSON PM. CONTRACTOR SHALL INSTALL NEW ROTORS AND SWING ARM ASSEMBLIES PER THE PLAN AND MANUFACTURER RECOMMENDATIONS.
ADDITIONAL ALTERNATIVE #9
OCHOA SOCCER COMPLEX - FIELD 3 NEW IRRIGATION TURF ROTORS
CONTRACTOR SHALL REMOVE AND RETURN EXISTING TURF ROTORS TO CITY OF TUCSON PM. CONTRACTOR SHALL INSTALL NEW ROTORS AND SWING ARM ASSEMBLIES PER THE PLAN AND MANUFACTURER RECOMMENDATIONS.
ADDITIONAL ALTERNATIVE #10
ADD ALT 9ADD ALT 8
ADD ALT 2
ADD ALT 2
ADD ALT 2
ADD ALT 2
ADD ALT 2
ADD ALT 2
ADD ALT 2
ADD ALT 2
ADD ALT 10
ADD ALT 1
ADD ALT 1
ADD ALT 1
ADD ALT 1
ADD ALT 1
ADD ALT 5
ADD ALT 5
ADD ALT 5
1. CONTRACTOR IS TO PROVIDE PRICING IN BID SCHEDULE FOR ADDITIONAL ALTERNATIVES.
2. CONTRACTOR SHALL REQUEST CLARIFICATION ON ANY ADDITIONAL ALTERNATIVES DURING THE BIDDING PROCESS. ALL
QUESTIONS SHALL BE DIRECTED TO THE CITY OF TUCSON PROCUREMENT MANAGER.
3. ADDITIONAL ALTERNATIVES #1-2, #5 AND #8-10 ARE PART OF THE OCHOA PARK SCOPE OF WORK. ADDITIONAL
ALTERNATIVES #3, #4, #6 AND #7 ARE FOR JACOBS PARK.
ADDITIONAL ALTERNATIVE NOTES:
1. OCHOA SOCCER COMPLEX: RENOVATE EXISTING WALKING PATH, ADD TREES AND DRIP IRRIGATION
BASE BID:
FIELD 2FIELD 1
FIELD 3
1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT. CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH REGULATIONS. CONTRACTOR SHALL ASK ALL QUESTIONS REGARDING PROCUREMENT OF MATERIALS OR COMPLIANCE WITH THE BUILD AMERICA BUY AMERICA ACT DURING THE BIDDING
PROCESS.
BUILD AMERICA BUY AMERICA ACT
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C1
.X _N
OT
E_
2.D W
G
PL
OT
TE
D:
/20 /20
:14 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
VA
VA
VA
VA
C2.1 C3.1 C4.1 C5.1 C6.1
C2.2 C3.2 C4.2 C5.2 C6.2
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C1
.X _K
EY
M_
2.D W
G
PL
OT
TE
D:
/20 /20
:15 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
REMOVAL NOTES
N F
AI
R
VI
EW
A
VE
REFERENCE NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C2
.X _D
EM
O_
2.D W
G
PL
OT
TE
D:
/20 /20
:15 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
REMOVAL NOTES
F
AI
R
VI
EW
A
VE
REFERENCE NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\S
HE
ET
S
IF
C\
8- C2
.X _D
EM
O_
2-
IF
C.
DW
G
PL
OT
TE
D:
/20 /20
:16 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
PB
PB PB PB
PB
PB
CONSTRUCTION NOTES
N F
AI
R
VI
EW
A
VE
GENERAL NOTES
REFERENCE NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C3
.X _S
IT
E_
2.D W
G
PL
OT
TE
D:
/20 /20
:15 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
CONSTRUCTION NOTES
F
AI
R
VI
EW
A
VE
GENERAL NOTES
REFERENCE NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\S
HE
ET
S
IF
C\
8- C3
.X _S
IT
E_
2-
IF
C.
DW
G
PL
OT
TE
D:
/20 /20
:16 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
PB PB PB
PB
PB
N F
AI
R
VI
EW
A
VE
LEGEND
GENERAL NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C4
.X _G
RA
D_
2.D W
G
PL
OT
TE
D:
/20 /20
:15 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
PBPB
PB
N F
AI
R
VI
EW
A
VE
LEGEND
GENERAL NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C4
.X _G
RA
D_
2.D W
G
PL
OT
TE
D:
/20 /20
:15 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
100% CD03.07.24
REFERENCE NOTES
PB PB PB
PB
PB
CONSTRUCTION NOTES
N F
AI
R
VI
EW
A
VE
REFERENCE NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C5
.X _U
TI
L_
2.D W
G
PL
OT
TE
D:
/20 /20
2:
P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
PB
CONSTRUCTION NOTES
N F
AI
R
VI
EW
A
VE
REFERENCE NOTES
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C5
.X _U
TI
L_
2.D W
G
PL
OT
TE
D:
/20 /20
2:
P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
PB PB PB
PB
PB
N F
AI
R
VI
EW
A
VE
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C6
.X _H
OR
Z_
2.D W
G
PL
OT
TE
D:
/20 /20
:16 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
PB
N F
AI
R
VI
EW
A
VE
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C6
.X _H
OR
Z_
2.D W
G
PL
OT
TE
D:
/20 /20
:16 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
RESERVED
PARKING
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
R T:
\20
\10
8_
CI
TY
_O
F_
TU
CS
ON
_J
AC
OB
S_
PA
RK
\C
AD
\23
8- C7
.X _D
ET
L_
2.D W
G
PL
OT
TE
D:
/20 /20
:16 P
M
TD-DEV-1223-00487
03.03.23 30% CD
07.10.23 75% CD
12.15.23 100% CD
100% CD02.23.24
1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT
NECESSARY TO INSTALL THE IMPROVEMENTS SHOWN ON THE PLANS.
2. ALL PIPING AND FITTINGS AND EQUIPMENT SHALL BE PURPLE IN COLOR,
IDENTIFYING RECLAIMED WATER AND INSTALLED PER THE RECLAIMED WATER
NOTES ON THIS SHEET. "RECLAIMED WATER" TAPE (LABEL FACING UP) TO BE
BURIED WITH PIPING IN TRENCHES.
3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONDUCT A THOROUGH SITE
INSPECTION AND REVIEW OF THE PROJECT CONSTRUCTION DOCUMENTS INCLUDING
BUT NOT LIMITED TO THE FOLLOWING: LANDSCAPE PLAN, CIVIL PLAN, ELECTRICAL
PLAN, GRADING PLAN AND ALL OTHER ASSOCIATED PLANS THAT EFFECT THIS WORK
PRIOR TO BEGINNING CONSTRUCTION. IF THE CONTRACTOR OBSERVES ANY
DISCREPANCIES AMONG THE CONSTRUCTION DOCUMENTS AND THE EXISTING
CONDITIONS ON SITE, IT IS THEIR RESPONSIBILITY TO CONTACT THE CITY OF
TUCSON PROJECT MANAGER IMMEDIATELY.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SURVEYING, STAKING AND GENERAL
LAYOUT REQUIREMENTS AS NEEDED TO CONSTRUCT THE PROJECT.
5. THE CONTRACTOR SHALL COORDINATE AS NECESSARY WITH THE CITY OF TUCSON
PROJECT MANAGER FOR SUCCESSFUL COMPLETION OF THIS WORK. ALL WORK IS
SUBJECT TO COORDINATION WITH THE CITY OF TUCSON PROJECT MANAGER. NO
WORK MAY BEGIN WITHOUT EXPRESSED WRITTEN CONSENT FROM CITY OF TUCSON
PROJECT MANAGER. CONTRACTOR SHALL ALSO SCHEDULE WORK SO AS TO
MINIMIZE UTILITY DOWN TIMES AND NOTIFY CITY OF TUCSON PROJECT MANAGER 48
HOURS IN ADVANCE OF ANY UTILITY SHUTDOWNS. CONTRACTOR SHALL PROVIDE
PROJECT SCHEDULE AT PRE-CONSTRUCTION MEETING.
6. THE CONTRACTOR SHALL CONFORM TO ALL LOCAL AND STATE REGULATIONS AND
INSTALL THE IRRIGATION SYSTEM AND ITS COMPONENTS PER THE MANUFACTURER'S
SPECIFICATIONS. THE CONTRACTOR SHALL OBTAIN AND PROVIDE PAYMENT FOR ALL
PERMITS REQUIRED BY ANY LOCAL AND STATE AGENCIES AND UTILITY COMPANIES
HAVING JURISDICTION OVER THIS SITE.
DETAILSYM. DESCRIP. MFR. MODEL NO. COMMENTS
IRRIGATION GENERAL NOTES (CONTINUED)
IRRIGATION SCHEDULE
SHEET
LARGE AREA
TURF ROTOR
46'
Hunter I-40-04-SSR-08 Turf Rotor, 4" Pop-Up. Adjustable to Full Circle.
Drain Check Valve, Stainless Steel Riser, 1" Female NPT Inlet Threads, Standard Nozzle.
RECLAIMED WATER NOTES
1. WHEN RECLAIMED WATER WILL BE USED IN AN IRRIGATION SYSTEM, ALL COMPONENTS,
SIGNAGE, SEPARATIONS, REQUIREMENTS FOR DYE TESTING AND MARKING
REQUIREMENTS SHALL CONFORM TO OR EXCEED TUCSON WATER'S RECLAIMED
USER'S MANUAL.
2. ONLY CLASS A+ RECLAIMED WATER, AS DEFINED BY ADEQ WILL BE PROVIDED TO
IRRIGATE LANDSCAPE PLANTS ON THIS PROJECT IN THE AREAS DESIGNATED TO
RECEIVE RECLAIMED WATER.
3. THE CONTRACTOR SHALL PREPARE A WORKER EDUCATION AND SAFETY GUIDELINE
REGARDING THE RISKS ASSOCIATED WITH WORKING WITH CLASS A+ RECLAIMED
WATER. THE WORKERS SHALL BE TRAINED IN THE PROPER PROCEDURES WHEN
WORKING WITH RECLAIMED WATER. VERIFICATION OF THIS TRAINING SHALL BE
SUBMITTED IN WRITING BY THE CONTRACTOR TO THE ENGINEER AT THE
PRE-CONSTRUCTION CONFERENCE, OR A LATER DATE THAT IS ACCEPTABLE TO THE
ENGINEER. THE WORKERS SHALL BE PROVIDED WITH ALL PERSONAL SAFETY
EQUIPMENT AND DEVICES NECESSARY FOR ACCOMPLISHING THE WORK IN
ACCORDANCE WITH OSHA REGULATION 29 CFR PART 1926, CONSTRUCTION SAFETY,
AND HEALTH. THE CONTRACTOR SHALL ALSO ENSURE THAT A “COMPETENT PERSON”
AS DEFINED IN 29 CFR PART 1926, IS PRESENT ON THE JOB AT ALL TIMES WHEN WORK
INVOLVING THE RECLAIMED WATER IS BEING PERFORMED. TRAINING, SAFETY
EQUIPMENT, AND OTHER COSTS ASSOCIATED WITH ENSURING THE HEALTH AND
SAFETY OF THE WORKERS AROUND THE RECLAIMED WATER SHALL BE BOURN BY THE
CONTRACTOR WITHOUT ANY ADDITIONAL EXPENSE TO THE CITY.
4. ANY TANK TRUCK AND OTHER EQUIPMENT THAT IS USED TO DISTRIBUTE RECLAIMED
WATER SHALL BE CLEARLY IDENTIFIED WITH WARNING SIGNS AS MAY BE REQUIRED BY
FEDERAL, STATE, OR LOCAL ORDINANCES.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ALL RECLAIMED WATER OUT
OF CONTACT WITH THE PUBLIC. AT NO TIME SHALL THE RECLAIMED WATER BE
ALLOWED TO ESCAPE ONTO THE ROADWAY OR INTO ANY DRAINAGE SYSTEMS.
6. ALL VALVE BOXES, VALVE BOX LIDS, AND REMOTE CONTROL VALVES, AND PVC PIPING
SHALL HAVE THE COLOR PURPLE FOR IDENTIFICATION OF A NON-POTABLE SYSTEM.
ALL PVC PIPE SHALL MEET THE PROVISIONS FOR IDENTIFICATION AS SET FORTH BY
THE ARIZONA STATE DEPARTMENT OF ENVIRONMENTAL QUALITY FOR THE USE OF
RECLAIMED WATER. COLOR IDENTIFICATION SHALL BE PURPLE AND SHALL BE
INTEGRAL WITH THE VALVE BOX AND PIPE MANUFACTURING PROCESS. SITE PAINTED
LIDS SHALL ONLY BE USED WHEN INTEGRALLY COLORED VALVE BOX LIDS OR OTHER
APPURTANCES ARE NOT AVAILABLE. PAINTING MUST RECEIVE PRIOR APPROVAL FROM
THE CITY REPRESENTATIVE.
7. THE CONTRACTOR SHALL COMPLY WITH ALL LAWS, FROM ALL APPROPRIATE
JURISDICTIONS, THAT PERTAIN TO THE CONSTRUCTION, OPERATION, AND
MAINTENANCE OF RECLAIMED WATER DISTRIBUTION SYSTEMS DURING
CONSTRUCTION AND DURING THE ESTABLISHMENT PERIOD. NO ADDITIONAL PAYMENT
SHALL BE MADE TO THE CONTRACTOR FOR CONSTRUCTING THE SYSTEM ACCORDING
TO THESE LAWS.
8. THE IRRIGATION SYSTEM WILL BE OPERATED TO AVOID PONDING OR PUDDLING. TO
MINIMIZE PONDING OR RUNOFF, THE RECLAIMED WATER SHALL BE APPLIED AT A RATE
THAT DOES NOT EXCEED THE INFILTRATION RATE OF THE SOIL.
9. SIGNS READING “CAUTION: RECLAIMED WATER, DO NOT DRINK” SHALL BE
PROMINENTLY DISPLAYED ON THE SITE AND AT ALL ENTRANCES TO THE SITE. IT IS
IMPORTANT TO PLACE THE CAUTION SIGNS AROUND ANY ABOVEGROUND IRRIGATION
EQUIPMENT. THE PURPOSE AND INTENT OF PROPERLY NOTIFYING THE PUBLIC IS TO
ENSURE THAT THE RECLAIMED WATER IS NOT MISUSED.
10. THERE SHALL BE NO CONNECTION BETWEEN THE POTABLE WATER SUPPLY AND ANY
PIPING CONTAINING RECLAIMED WATER.
11. PERSONNEL WORKING IN AND ABOUT THE REUSE SITE SHALL BE INFORMED THAT
RECLAIMED WATER IS BEING USED AND SHALL TAKE APPROPRIATE SAFETY
PRECAUTIONS.
12. RECLAIMED WATER IRRIGATION SYSTEMS ARE SUBJECT TO RESTRICTION IN
CONSTRUCTION THAT THE CONTRACTOR SHALL MAKE HIMSELF AWARE OF ALL
APPLICABLE RESTRICTIONS THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL,
STATE, AND MUNICIPAL CODES REGARDING CONSTRUCTION OF THE RECLAIMED
WATER IRRIGATION DISTRIBUTION SYSTEMS, PARTICULARLY WITH RESPECT TO
WORKER SAFETY, WORKER HYGIENE, WORKER TRAINING AND REQUIRED SEPARATION
DISTANCES BETWEEN ANY RECLAIMED WATER LINE AND ANY POTABLE WATER LINE.
HUNTER 60 psi design pressure.
Lasco T 922-212 Swing Joint Assembly
7. THE CONTRACTOR MUST VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES
PRIOR TO CONSTRUCTION. IF THE CONTRACTOR FAILS TO DO SO AND DAMAGES ANY
UNDERGROUND UTILITIES THROUGH THE COURSE OF HIS WORK THE CONTRACTOR
SHALL PAY FOR ANY REPAIR WORK ASSOCIATED WITH SAID DAMAGES. ALL
UNDERGROUND UTILITY WORK SHALL BE INSPECTED BY THE CITY OF TUCSON PROJECT
MANAGER PRIOR TO BACKFILLING. THIS SHALL INCLUDE, BUT IS NOT LIMITED TO:
IRRIGATION, POTABLE WATER, SEWER, ELECTRICAL AND GAS. CONTRACTOR SHALL
NOTIFY CITY OF TUCSON PROJECT MANAGER WITH A MINIMUM OF 24 HOURS
ADVANCED NOTICE. 48 HOURS IS REQUIRED.
8. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PRESERVE AND
PROTECT EXISTING IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO: ROADS, CURB,
FENCING, LIGHTING, STRUCTURES, UTILITIES, TREES AND IRRIGATION TO REMAIN IN
PLACE. ANY DAMAGED ITEMS WILL BE REPAIRED AND/OR REPLACED AT CONTRACTOR'S
EXPENSE. SHOULD DAMAGE OCCUR, CONTRACTOR SHALL NOTIFY CITY OF TUCSON
PROJECT MANAGER IMMEDIATELY AND PROVIDE AN INCIDENT REPORT.
a. ALL REPAIRS/REPLACEMENTS SHALL REQUIRE WRITTEN SUBMITTAL PERTAINING
TO RELEVANT PRODUCTS, MEANS AND METHODS FOR CITY OF TUCSON PROJECT
MANAGER APPROVAL PRIOR TO INITIATING THE WORK. ALL REPAIRS/
REPLACEMENTS SHALL BE MADE AT THE CONTRACTOR'S EARLIEST OPPORTUNITY
AND SHALL REQUIRE VISUAL INSPECTION AND APPROVAL BY CITY OF TUCSON
PROJECT MANAGER. CITY OF TUCSON PROJECT MANAGER MAY WITHHOLD FINAL
ACCEPTANCE OF THE PROJECT UNTIL SAID ITEMS HAVE BEEN SATISFACTORILY
ADDRESSED.
9. ALL WORK AREAS ASSOCIATED WITH THIS PROJECT SHALL BE PROPERLY SECURED
AND CORDONED OFF TO PREVENT ACCESS FROM THE GENERAL PUBLIC. A MINIMUM 6'
CHAINLINK FENCE IS REQUIRED AT ALL TIMES. CONTRACTOR SHALL PROVIDE A
FENCING PLAN AT PRE-CONSTRUCTION MEETING.
10. THIS FACILITY WILL REMAIN IN OPERATION DURING CONSTRUCTION. CONTRACTOR
SHALL MAINTAIN ADEQUATE AND SAFE PUBLIC INGRESS AND EGRESS TO THE FACILITY
AND ALL ITS AMENITIES NOT DIRECTLY AFFECTED BY CONSTRUCTION FOR THE
DURATION OF THE PROJECT. NO PUBLIC ACCESS SHALL BE RESTRICTED WITHOUT
WRITTEN CONSENT OF CITY OF TUCSON PROJECT MANAGER.
11. IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED
WITHIN THE PROJECT LIMITS AND WITHIN LANDSCAPE AREAS. ANY EQUIPMENT SHOWN
OUTSIDE OF THESE LIMITS IS SHOWN FOR GRAPHICAL CLARITY ONLY. IF THERE IS A
QUESTION REGARDING THE LOCATION OF ANY COMPONENT OF THE IRRIGATION
SYSTEM, IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE CITY OF TUCSON
PROJECT MANAGER. IF THE CONTRACTOR NEGLECTS TO NOTIFY THE NECESSARY
PARTIES, THE CONTRACTOR SHALL PAY FOR ANY REPLACEMENT OR MODIFICATION TO
ENSURE PROPER LOCATION AND OPERATION OR THE IRRIGATION SYSTEM AND ITS
COMPONENTS.
12. THE CONTRACTOR ASSUMES ALL LIABILITY ASSOCIATED WITH THE MODIFICATION OF
THE IRRIGATION SYSTEM DESIGN WITHOUT NOTIFYING THE CITY OF TUCSON PROJECT
MANAGER.
13. ALL IRRIGATION EQUIPMENT IS TO BE AS SPECIFIED, OR APPROVED EQUAL PER THE
DISCRETION OF THE CITY OF TUCSON PROJECT MANAGER.
IRRIGATION GENERAL NOTES
21 L4.2
14. ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES, INCLUDING TURF AREAS SHALL
BE RESTORED TO THEIR ORIGINAL CONDITION PRIOR TO FINAL ACCEPTANCE.
15 Hunter I-40-04-SSR-15 Turf Rotor, 4" Pop-Up. Adjustable to Full Circle.
Drain Check Valve, Stainless Steel Riser, 1" Female NPT Inlet Threads, Standard Nozzle.
LARGE AREA
TURF ROTOR
55'
HUNTER 60 psi design pressure.
Lasco T 922-212 Swing Joint Assembly
21 L4.2
15. ALL TRENCHES SHALL BE RETURNED TO EXISTING GRADE, CLEARED OF ALL ROCKS
AND MATERIALS GREATER THAN 1". IN TURF AREAS, CONTRACTOR SHALL PROVIDE
MANUALLY BROADCAST SEED FOR REVEGETATION OF MAINLINE TRENCHES AND
OTHER TRENCHES GREATER THAN 6" IN WIDTH AT FINISH GRADE.
16. CONTRACTOR SHALL FINE TUNE AND ADJUST NOZZLE DIRECTION AND RADIUS TO
REDUCE OVER SPRAY ONTO PAVING OR HARD SURFACES, BENCHES, PICNIC TABLES,
WATER FOUNTAINS, ETC.
17. ALL SPRAY IRRIGATION SHALL BE KEPT 18" MINIMUM FROM PUBLIC SIDEWALKS OR
PATHS UNLESS OTHERWISE DIRECTED BY CITY OF TUCSON PROJECT MANAGER.
18. THE TURF IRRIGATION SYSTEM SHALL BE DESIGNED TO APPLY WATER AT THE
FOLLOWING MINIMUM APPLICATION EFFICIENCIES AS MEASURED BY THE LOW
QUARTER DISTRIBUTION UNIFORMITY METHOD AFTER CONSTRUCTION:
· ROTORS 65% DU MEASURED BY AUDIT.
20. THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO PROVIDE 2" OF WATER DURING AN
EIGHT HOUR PER NIGHT (10 PM TO 6 AM) WATERING WINDOW ON A 6 DAY SCHEDULE TO
ALLOW MOW DAYS. ESTABLISHMENT WATERING WILL REQUIRE ADDITIONAL IRRIGATION
FOR A FOUR TO SIX WEEK PERIOD. COORDINATE SCHEDULE WITH CITY OF TUCSON
PROJECT MANAGER AND IRRIGATOR.
SYMBOL DESCRIPTION DETAIL QTY.
CONCRETE - STANDARD GRAY - MEDIUM
BROOM FINISH 1/L4.1 2,564 SF
EXISTING TURF TO REMAIN -
EXISTING GRASS AREAS ARE TO BE
REPAIRED WHERE NEEDED DUE TO
IRRIGATION TRENCHING OR PROJECT
IMPROVEMENTS. CONTRACTOR IS TO
VERIFY LIMITS OF GRASS RESEEDING WITH
THE COT PROJECT MANAGER PRIOR TO
CONSTRUCTION. GRASS IS TO BE BY
HYDROSTOLON - TIFTUF BERMUDA HYBRID
GRASS OR APPROVED EQUAL.
N/A 298,243 SF
SURFACING SCHEDULE
POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51
HARDSCAPE SCHEDULE
SITE AMENITY NOTES
POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51
HARDSCAPE SCHEDULE
SITE AMENITY NOTES
SYMBOL BOTANICAL / COMMON NAME SIZE QTY
TREES, SEE DETAIL 3/L4.1, 5/L4.1
Ebenopsis ebano Texas Ebony 15 GAL 5
Prosopis seedless hybrid 'Leslie Roy' Leslie Roy Mesquite 15 GAL 23
Existing to Remain
LANDSCAPE SCHEDULE
EMITTER
DRIP LATERAL
EMITTER SCHEDULE
PLANT TYPE
EXISTING TREE
24" BOX TREES
TREE
OUTLET
SYM. DESCRIPTION
IRRIGATION SCHEDULE
NOTES
DETAIL
LARGE AREA TURF ROTOR 57'
HUNTER MPE-20 2 GPH EMITTERS
HUNTER MPE-20 2 GPH EMITTERS
MULTI-OUTLET EMITTER 44, 45 / L4.2
38 / L4.2
1. ALL TREES SHALL BE IRRIGATED WITH HUNTER MPE-20
MULTI-PORT EMITTERS IN 6" ROUND BOX. ALL 24" BOX
TREES TO HAVE MIN. 1 PER TREE.
2. ALL PIPE SHALL BE INSTALLED WITH IDENTIFICATION
TEXT FACING UP IN TRENCH AND MARKED FOR
RECLAIMED WATER USE. ALL EMITTER BOXES TO
HAVE PURPLE LID.
15 21 / L4.2
END CAP 34 / L4.2
NOTES & SCHEDULES
1. ALL REQUIRED LANDSCAPING, IRRIGATION SYSTEMS, WALLS, SCREENING DEVICES, CURBING, AND DETENTION BASIN LANDSCAPE IMPROVEMENTS ON THE SITE OR WITHIN THE ABUTTING
RIGHT-OF-WAY SHALL BE MAINTAINED AS SHOWN ON THE APPROVED PLANS. THE PROPERTY
OWNER IS RESPONSIBLE FOR PROPER MAINTENANCE TO ACHIEVE PERMANENT, SAFE, AND
SUCCESSFUL LANDSCAPING AS REQUIRED BY ARTICLE 7.6.8 OF THE COT UDC.
2. PLANT PRUNING SHOULD BE COMPLETED PER STANDARDS OUTLINED IN ALCA SUSTAINABLE
LANDSCAPE MANAGEMENT MANUAL.THESE INCLUDE BUT ARE NOT LIMITED TO:
· DESERT TREES SHOULD BE PRUNED JUNE-OCTOBER
· DECIDUOUS AND EVERGREEN TREES SHOULD BE PRUNED DECEMBER-JANUARY
· YUCCA AND HESPERALOE SHOULD BE PRUNED SEPTEMBER-NOVEMBER
· GRASSES SHOULD BE PRUNED DECEMBER-FEBRUARY
· FROST SENSITIVE PLANS SHOULD BE PRUNED IN MARCH
· CASIAS AND OTHER DESERT SHRUBS SHOULD BE PRUNED APRIL-MAY
3. THE CONTRACTOR SHALL PROVIDE A SEASONAL MAINTENANCE SCHEDULE WHICH SHALL
BEGIN ON APRIL 1 AND END ON OCTOBER 1 TO ENSURE THE EFFICIENCY AND LONGEVITY OF
THE IRRIGATION SYSTEM. THE MAINTENANCE SCHEDULE SHALL INCLUDE BUT IS NOT LIMITED
TO THE FOLLOWING LIST OF BEST MANAGEMENT PRACTICES:
· CHECK ENTIRE IRRIGATION SYSTEM FOR LEAKS
· VERIFY PROPER OPERATION OF ALL CONTROL VALVES, SPRAY HEADS, AND DRIP EMITTERS.
· ADJUST SPRAY IRRIGATION TO PROVIDE UNIFORM COVERAGE AND NO OVERSPRAY ON
PAVEMENT
· CHECK CONTROLLER PROGRAMMING AND ADJUST FOR SEASONAL CHANGES AS NECESSARY.
· VERIFY THAT THE WATER SUPPLY AND PRESSURE ARE AS STATED IN THE DESIGN.
· CERTIFY THE BACKFLOW PREVENTION DEVICE AND SUBMIT TEST RESULTS TO THE PROPERTY
MANAGER.
· PERIODICALLY VERIFY THE SENSORS IN THE IRRIGATION SYSTEM ARE OPERATING
CORRECTLY.
· IMMEDIATELY SERVICE ANY COMPONENTS THAT ARE NOT OPERATING AS DESIGNED.
· IMMEDIATELY ADDRESS ANY ITEMS THAT VIOLATE REGULATIONS FOR WATER CONSERVATION,
SUCH AS LEAKS, OVER SPRAY, STUCK VALVES, OR IMPROPER PROGRAMMING.
4. THE PROPERTY OWNER IS RESPONSIBLE FOR REPLACEMENT OF ANY PLANT MATERIAL,
SHOULD ANY NOT SURVIVE, AND REPLACEMENT / UPKEEP OF INERT GROUNDCOVERS AND
HARDSCAPE MATERIALS, AS REQUIRED BY ARTICLE 7.6.8 OF THE COT UDC.
L1.1
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
MAINTENANCE SCHEDULE
LANDSCAPE NOTES
1. WRITTEN DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS.
2. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL PLANT QUANTITIES.
3. LOCATION OF ALL ELEMENTS ON THIS PLAN SHALL BE APPROVED BY THE OWNER'S
REPRESENTATIVE OR LANDSCAPE ARCHITECT, PRIOR TO INSTALLATION.
4. ALL DISTURBED, GRUBBED, GRADED, OR BLADED AREAS NOT OTHERWISE IMPROVED SHALL BE
LANDSCAPED, RESEEDED, OR TREATED WITH AN INORGANIC OR ORGANIC GROUNDCOVER.
5. THE SCHEDULE FOR PLANTING OF TREES AND SHRUBS SHALL BE AT THE DISCRETION OF THE
CONTRACTOR. PLANTING DURING EXTREMELY COLD, HOT, OR WINDY PERIODS SHALL BE
PERFORMED AT THE CONTRACTOR'S RISK. PLANTS WHICH ARE DAMAGED OR DIE PRIOR TO
FINAL ACCEPTANCE AS A RESULT OF EXTREME WEATHER CONDITIONS SHALL BE REMOVED
AND REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.
6. PLANT SIZE, LOCATION, AND SPACING:
· TREES AND SHRUBS ARE TO BE LOCATED SO THAT, AT MATURITY, THEY DO NOT INTERFERE
WITH EXISTING ONSITE OR OFFSITE UTILITY SERVICE LINES OR UTILITY EASEMENTS OR
WITH SOLAR ACCESS TO AN ADJACENT PROPERTY.
· ALL SHRUBS AND GROUNDCOVERS TO BE A MINIMUM OF 3' FROM BACK OF CURB OR BACK
OF SIDEWALK.
7. PLANT PLACEMENT TO BE FIELD ADJUSTED AS NEEDED TO AVOID PROPOSED UTILITIES,
EXISTING PRESERVED VEGETATION, AND OTHER FIELD CONDITIONS. CONTACT THE OWNER'S
REPRESENTATIVE OR LANDSCAPE ARCHITECT FOR RELOCATION OF PLANTS IN QUESTIONABLE
AREAS.
8. FINAL PLANT LOCATIONS MUST BE IN COMPLIANCE WITH ALL UTILITY SETBACK
REQUIREMENTS.
9. THE CONTRACTOR SHALL SCHEDULE UTILITY LOCATION SERVICES AND TAKE EXTREME CARE
WHILE WORKING WITHIN THE PROJECT AREA AS TO NOT DISTURB ANY EXISTING UTILITIES OR
STRUCTURES ON OR ADJACENT TO THE PROJECT AREA. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR REPLACING AND OR REPAIRING ANY EXISTING STRUCTURES OR UTILITIES
DAMAGED DURING CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.
10. ALL WORK SHALL BE CONFINED TO THE AREA WITHIN THE PROPERTY LIMITS AS SHOWN ON
THE PLANS. ANY AREAS OR IMPROVEMENTS DISTURBED OUTSIDE THESE LIMITS SHALL BE
REVEGETATED TO THEIR ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE. IN THE
EVENT THE CONTRACTOR REQUIRES A MODIFICATION TO THE CONSTRUCTION LIMITS,
WRITTEN PERMISSION MUST BE OBTAINED FROM THE OWNER'S REPRESENTATIVE PRIOR TO
ANY DISTURBANCE OUTSIDE OF THE LIMITS OF WORK.
11. NOTIFY THE OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT 48 HOURS IN ADVANCE OF
ANY INSPECTIONS AND / OR APPROVALS OF LANDSCAPE MATERIAL AND IRRIGATION
PRODUCTS PRIOR TO INSTALLATION.
12. THE CONTRACTOR SHALL WARRANTY THE PLANT MATERIAL, IRRIGATION SYSTEM AND
WORKMANSHIP FOR A MINIMUM PERIOD OF ONE YEAR.
13. ALL TREES ARE TO BE STAKED AND GUYED PER DETAILS FOR A MINIMUM PERIOD OF ONE
YEAR AS NECESSARY OR AT THE DISCRETION OF THE OWNER'S REPRESENTATIVE. THE
CONTRACTOR SHALL REMOVE STAKING AND GUYING PRIOR TO THE FINAL, ONE YEAR WALK
THROUGH.
14. A MINIMUM OF THREE FEET (3') ACCESS TO AND CLEARANCE AROUND ALL FIRE HYDRANTS.
15. ROOT BARRIER TO BE UTILIZED WHERE NECESSARY FOR TREES ADJACENT TO CURBS AND
SIDEWALKS.
ADD ALT 8, 9, AND 10
1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT. CONTRACTOR IS
RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH REGULATIONS. CONTRACTOR
SHALL ASK ALL QUESTIONS REGARDING PROCUREMENT OF MATERIALS OR COMPLIANCE WITH
THE BUILD AMERICA BUY AMERICA ACT DURING THE BIDDING PROCESS.
PB PB PB
PB
PB
N O
R T
H F
A
IR
V
IE
W A
V E
N U
E
PR
OP
ER
TY
LI
NE
PROPERTY LINE
PR
OP
ER
TY
LI
NE
NEW CONCRETE
REPLACEMENT TYP. -
SEE CIVIL PLANS
EXISTING NATURAL TURF TO
REMAIN - CONTRACTOR SHALL
REPAIR ALL TURF DISTURBED
BY CONSTRUCTION ACTIVITIES
EXISTING NATURAL TURF TO
REMAIN - CONTRACTOR SHALL
REPAIR ALL TURF DISTURBED
BY CONSTRUCTION ACTIVITIES
NEW CONCRETE
REPLACEMENT TYP. -
SEE CIVIL PLANS
NEW CONCRETE
REPLACEMENT TYP. -
SEE CIVIL PLANS
NEW CONCRETE NEW CONCRETE
SYMBOL DESCRIPTION DETAIL QTY.
CONCRETE - STANDARD GRAY - MEDIUM
BROOM FINISH 1/L4.1 2,564 SF
EXISTING TURF TO REMAIN -
EXISTING GRASS AREAS ARE TO BE
REPAIRED WHERE NEEDED DUE TO
IRRIGATION TRENCHING OR PROJECT
IMPROVEMENTS. CONTRACTOR IS TO
VERIFY LIMITS OF GRASS RESEEDING WITH
THE COT PROJECT MANAGER PRIOR TO
CONSTRUCTION. GRASS IS TO BE BY
HYDROSTOLON - TIFTUF BERMUDA HYBRID
GRASS OR APPROVED EQUAL.
N/A 298,243 SF
SURFACING SCHEDULE
POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51
HARDSCAPE SCHEDULE
SITE AMENITY NOTES
POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51
HARDSCAPE SCHEDULE
SITE AMENITY NOTES
SYMBOL BOTANICAL / COMMON NAME SIZE QTY
TREES, SEE DETAIL 3/L4.1, 5/L4.1
Ebenopsis ebano Texas Ebony 15 GAL 5
Prosopis seedless hybrid 'Leslie Roy' Leslie Roy Mesquite 15 GAL 23
Existing to Remain
LANDSCAPE SCHEDULE
HARDSCAPE & LANDSCAPE
PLAN
L2.1
MATCHLINE - SEE SHEET L2.2
KEY MAP
N.
F
AI
RV
IE
W
A
VE
SHEET L2.1
SHEET L3.1
SHEET L2.2
SHEET L3.2
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
NORTH
0 3015 60
SCALE 1" = 30'
1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT.
CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH
REGULATIONS. CONTRACTOR SHALL ASK ALL QUESTIONS REGARDING
PROCUREMENT OF MATERIALS OR COMPLIANCE WITH THE BUILD AMERICA BUY
AMERICA ACT DURING THE BIDDING PROCESS.
PB
PB PB
N O
R T
H F
A
IR
V
IE
W A
V E
N U
E
PR
OP
ER
TY
LI
NE
PR
OP
ER
TY
LI
NE
PROPERTY LINE
EXISTING DG
TO REMAIN
NEW CONCRETE
REPLACEMENT TYP. -
SEE CIVIL PLANS
LOW WATER
CROSSING - SEE
CIVIL PLANS
PLAYGROUND
RENOVATION
UNDER
SEPARATE
PERMIT
S.V.T.
S.V.T.
EXISTING NATURAL TURF TO
REMAIN - CONTRACTOR SHALL
REPAIR ALL TURF DISTURBED
BY CONSTRUCTION ACTIVITIES
CONTRACTOR TO COORDINATE THE FOLLOWING REPAIRS
WITH OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION:
REPLACE DRIP EDGE AND PAINT COLOR TO MATCH EXISTING,
REPLACE RESTROOM DOORS, REPAIR STEEL DIVIDER WITH
WELD STEEL PLATE AND PAINT TO MATCH EXISTING, REPLACE
EXTERIOR LIGHTS UNDER ROOF EVES WITH LED FIXTURES.
CONTRACTOR SHALL VERIFY
HORIZONTAL AND VERTICAL
LOCATION OF SEPTIC
SYSTEM LEACH FIELD AND
APPURTENANCES PRIOR TO
CONSTRUCTION AND
PROTECT IN PLACE
CONTRACTOR TO
RAKE DG BACK
AFTER TREE
INSTALLATION
CONTRACTOR TO RAKE DG BACK
AFTER TREE INSTALLATION
CONTRACTOR TO
RAKE DG BACK
AFTER TREE
INSTALLATION
NEW CONCRETE
REPLACEMENT
TYP. - SEE CIVIL
PLANS
NEW CONCRETE
REPLACEMENT
TYP. - SEE CIVIL
PLANS
NEW CONCRETE
REPLACEMENT
TYP. - SEE CIVIL
PLANS
NEW CONCRETE
REPLACEMENT
TYP. - SEE CIVIL
PLANS
REPLACE ADA
RAMP AND CURB -
SEE CIVIL PLANS
NEW CONCRETE
REPLACEMENT
TYP. - SEE CIVIL
PLANS
NEW CONCRETE
REPLACEMENT
TYP. - SEE CIVIL
PLANS
TRASH ENCLOSURE
- SEE CIVIL PLANS
CONTRACTOR
SHALL
COORDINATE
LWCF SIGN
INSTALLATION
WITH COT PM
ADD ALT 5
ADD ALT 5
ADD
ALT 5
SYMBOL DESCRIPTION DETAIL QTY.
CONCRETE - STANDARD GRAY - MEDIUM
BROOM FINISH 1/L4.1 2,564 SF
EXISTING TURF TO REMAIN -
EXISTING GRASS AREAS ARE TO BE
REPAIRED WHERE NEEDED DUE TO
IRRIGATION TRENCHING OR PROJECT
IMPROVEMENTS. CONTRACTOR IS TO
VERIFY LIMITS OF GRASS RESEEDING WITH
THE COT PROJECT MANAGER PRIOR TO
CONSTRUCTION. GRASS IS TO BE BY
HYDROSTOLON - TIFTUF BERMUDA HYBRID
GRASS OR APPROVED EQUAL.
N/A 298,243 SF
SURFACING SCHEDULE
POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51
HARDSCAPE SCHEDULE
SITE AMENITY NOTES
POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51
HARDSCAPE SCHEDULE
SITE AMENITY NOTES
SYMBOL BOTANICAL / COMMON NAME SIZE QTY
TREES, SEE DETAIL 3/L4.1, 5/L4.1
Ebenopsis ebano Texas Ebony 15 GAL 5
Prosopis seedless hybrid 'Leslie Roy' Leslie Roy Mesquite 15 GAL 23
Existing to Remain
LANDSCAPE SCHEDULE
HARDSCAPE & LANDSCAPE
PLAN
L2.2
30% CD
MATCHLINE - SEE SHEET L2.1
KEY MAP
N.
F
AI
RV
IE
W
A
VE
SHEET L2.1
SHEET L3.1
SHEET L2.2
SHEET L3.2
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
NORTH
0 3015 60
SCALE 1" = 30'
1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT.
CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH
REGULATIONS. CONTRACTOR SHALL ASK ALL QUESTIONS REGARDING
PROCUREMENT OF MATERIALS OR COMPLIANCE WITH THE BUILD AMERICA BUY
AMERICA ACT DURING THE BIDDING PROCESS.
08 08
15 15
08 08
15 15 15 15
LIMIT OF
WORK
LIMIT OF
WORK
LIMIT OF
WORK
ADD ALT #8 - FIELD LOCATE & REPLACE
EXISTING ROTORS WITH HUNTER
I-40-04-SS-R (NOZZLE PER PLAN) AND LASCO
T 922-212 SWING JOINTS
ADD ALT #9 - FIELD LOCATE & REPLACE
EXISTING ROTORS WITH HUNTER
I-40-04-SS-R (NOZZLE PER PLAN) AND LASCO
T 922-212 SWING JOINTS
N O
R T
H F
A
IR
V
IE
W A
V E
N U
E
PR
OP
ER
TY
LI
NE
PROPERTY LINE
PR
OP
ER
TY
LI
NE
CONTRACTOR TO LOCATE AND CONFIRM
WORKING CONDITION OF EXISTING
LATERALS. CONNECT TO AND EXTEND
LATERALS TO NEW TREES.
CONTRACTOR TO LOCATE AND
CONFIRM WORKING CONDITION
OF EXISTING LATERALS.
CONNECT TO AND EXTEND
LATERALS TO NEW TREES.
CONTRACTOR TO LOCATE AND CONFIRM WORKING
EMITTER
DRIP LATERAL
EMITTER SCHEDULE
PLANT TYPE
EXISTING TREE
24" BOX TREES
TREE
OUTLET
SYM. DESCRIPTION
IRRIGATION SCHEDULE
NOTES
DETAIL
LARGE AREA TURF ROTOR 57'
HUNTER MPE-20 2 GPH EMITTERS
HUNTER MPE-20 2 GPH EMITTERS
MULTI-OUTLET EMITTER 44, 45 / L4.2
38 / L4.2
1. ALL TREES SHALL BE IRRIGATED WITH HUNTER MPE-20
MULTI-PORT EMITTERS IN 6" ROUND BOX. ALL 24" BOX
TREES TO HAVE MIN. 1 PER TREE.
2. ALL PIPE SHALL BE INSTALLED WITH IDENTIFICATION
TEXT FACING UP IN TRENCH AND MARKED FOR
RECLAIMED WATER USE. ALL EMITTER BOXES TO
HAVE PURPLE LID.
15 21 / L4.2
END CAP 34 / L4.2
ADD ALT BOUNDARY
IRRIGATION PLAN
L3.1
KEY MAP
N.
F
AI
RV
IE
W
A
VE
SHEET L3
SHEET L5
SHEET L7
SHEET L4
SHEET L6
SHEET L8
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
MATCHLINE - SEE SHEET L3.2
CONTRACTOR IS TO REPLACE ALL IRRIGATION ROTORS
INCLUDING THE SWING ARM ASSEMBLY. ADJUST HEAD
INSTALLATION DEPTH AS NEEDED PER DETAIL 5, SHEET
L4.1. ADJUSTMENT OF HEAD LOCATIONS TO BE
PROVIDED ONLY AT DIRECTION OF CITY OF TUCSON PM.
ALL TURF DAMAGED DURING TRENCHING AND
CONSTRUCTION ACTIVITIES SHALL BE REPAIRED USING
HYDROSTOLONS.
NORTH
0 3015 60
SCALE 1" = 30'
EMITTER
DRIP LATERAL
EMITTER SCHEDULE
PLANT TYPE
EXISTING TREE
24" BOX TREES
TREE
OUTLET
SYM. DESCRIPTION
IRRIGATION SCHEDULE
NOTES
DETAIL
LARGE AREA TURF ROTOR 57'
HUNTER MPE-20 2 GPH EMITTERS
HUNTER MPE-20 2 GPH EMITTERS
MULTI-OUTLET EMITTER 44, 45 / L4.2
38 / L4.2
1. ALL TREES SHALL BE IRRIGATED WITH HUNTER MPE-20
MULTI-PORT EMITTERS IN 6" ROUND BOX. ALL 24" BOX
TREES TO HAVE MIN. 1 PER TREE.
2. ALL PIPE SHALL BE INSTALLED WITH IDENTIFICATION
TEXT FACING UP IN TRENCH AND MARKED FOR
RECLAIMED WATER USE. ALL EMITTER BOXES TO
HAVE PURPLE LID.
15 21 / L4.2
END CAP 34 / L4.2
ADD ALT BOUNDARY
15 15 15 151515
08 08
08 08
08 08
151515
LIMIT OF WORK
LIMIT OF
WORK
LIMIT OF
WORK
(3) EXISTING 2"
RECLAIMED WATER
METERS TO
REMAIN IN PLACE.
ADD ALT #10 - FIELD LOCATE & REPLACE
EXISTING ROTORS WITH HUNTER
I-40-04-SS-R (NOZZLE PER PLAN) AND LASCO
T 922-212 SWING JOINTS
N O
R T
H F
A
IR
V
IE
W A
V E
N U
E
PR
OP
ER
TY
LI
NE
PR
OP
ER
TY
LI
NE
PROPERTY LINE
LIMIT OF
WORK
CONTRACTOR TO LOCATE AND
CONFIRM WORKING CONDITION
OF EXISTING LATERALS.
CONNECT TO AND EXTEND
LATERALS TO NEW TREES.
CONTRACTOR TO LOCATE AND
CONFIRM WORKING CONDITION
OF EXISTING LATERALS.
CONNECT TO AND EXTEND
LATERALS TO NEW TREES.
CONTRACTOR TO LOCATE AND
CONFIRM WORKING CONDITION
OF EXISTING LATERALS.
CONNECT TO AND EXTEND
LATERALS TO NEW TREES.
CONTRACTOR TO
LOCATE AND CONFIRM
WORKING CONDITION OF
EXISTING LATERALS.
CONNECT TO AND
EXTEND LATERALS TO
NEW TREES.
CONTRACTOR TO LOCATE AND CONFIRM WORKING
CONDITION OF EXISTING LATERALS. CONNECT TO
AND EXTEND LATERALS TO NEW TREES.
IRRIGATION PLAN
L3.2
KEY MAP
N.
F
AI
RV
IE
W
A
VE
SHEET L3
SHEET L5
SHEET L7
SHEET L4
SHEET L6
SHEET L8
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
MATCHLINE - SEE SHEET L3MATCHLINE - SEE SHEET L3.1
CONTRACTOR IS TO REPLACE ALL IRRIGATION ROTORS
INCLUDING THE SWING ARM ASSEMBLY. ADJUST HEAD
INSTALLATION DEPTH AS NEEDED PER DETAIL 5, SHEET
L4.1 . ADJUSTMENT OF HEAD LOCATIONS TO BE
PROVIDED ONLY AT DIRECTION OF CITY OF TUCSON PM.
ALL TURF DAMAGED DURING TRENCHING AND
CONSTRUCTION ACTIVITIES SHALL BE REPAIRED USING
HYDROSTOLONS.
NORTH
0 3015 60
SCALE 1" = 30'
LANDSCAPE DETAILS
L4.1
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
1 2
4" THICK CONCRETE PAVING
FINISH AS NOTED ON HARDSCAPE
PLANS - 3,000 PSI AT 28 DAYS
TOOLED JOINT, 1/4" RADIUS
SPACE EQUAL TO WIDTH OF
WALK UNLESS NOTED
OTHERWISE. DEPTH TO 1" MIN.
FIBER EXPANSION JOINT WITH
TRAFFIC SEALANT
SAW CUT JOINT, 1/4" X 2" DEPTH.
DRY CUT JOINT TO AVOID
SPALLING. JOINTS SHALL BE CUT
BETWEEN 24-48 HOURS OF
INSTALLATION
1/2" RADIUS TOOL EDGE
FINISH GRADE
ROCK SURFACING PER
LANDSCAPE PLAN
PREPARED SUBGRADE PER
GEOTECH RECOMMENDATIONS,
95% COMPACTED SUBGRADE
CONCRETE
SCALE: NTS
4" 2" 1"
2 1 3 4 5 6
NOTE:
1. C.I.P. CONCRETE PER PLANS AND SPECS. SPACE CONTROL JOINTS THE WIDTH OF THE
WALK OR AS SHOWN ON PLANS WITH EXPANSION JOINTS @ 10' O.C. MAX. OR WHERE
NOTED.
2. EXPANSION JOINTS @ ALL CONSTRUCTION JOINTS, SLAB EDGES OF ALL STRUCTURES
3. USE 16P NAILS THROUGH EXPANSION JOINT MATERIAL @ 12" O.C. TO HOLD MATERIAL IN
PLACE.
4. CONCRETE SLABS NOT TO EXCEED 300 SQ. FT. WITHOUT AN EXPANSION JOINT.
5. PROVIDE A 1" REVEAL FOR ALL ADJACENT GROUND PLANE TREATMENTS.
3 4
END PIPE: 4" DIAMETER
SCHEDULE 40 PIPE
MID PIPE: 4" DIAMETER
SCHEDULE 40 PIPE
MALLEABLE STEEL CAP - TACK
WELD TO POST
CONCRETE FOOTER
SLOPE TO DRAIN
4" HOLE
2" DIA. (6x25) GALVANIZED STEEL
WIRE ROPE CABLE - MINIMIZE
SAG
AT ENDS, LOOP CABLE & FASTEN
WITH 3 CABLE CLAMPS
FINISH GRADE
POST AND CABLE BARRIER
SCALE: 1" = 1'-0"
3'-0"
12'-0" O.C. MAX.
3"
1'-4"
1'-0"
4"
NOTE:
1. GRIND SMOOTH WELDS.
2. PRIME ALL POSTS WITH RUST
INHIBITING PAINT. COLOR :
HYPER BLUE - SW 6965
3. ALL CONCRETE SHALL HAVE A
MIN. COMPRESSIVE STRENGTH
OF 3,000 PSI. AT 28 DAYS.
4" 4"
SINGLE-TRUNK TREE PLANTING
SCALE: NTS
3' MIN.
5' MAX.
1X 2X
3"
30"
NOTES:
1. SET TOP OF ROOTBALL 4'' BELOW TOP OF TREE WELL. ORGANIC MULCH AS REQUIRED.
2. DRIVE TREE STAKES 3' MIN. INTO GROUND TO FIRM BEARING, TAKE CARE NOT TO DAMAGE
ROOTBALL. SAW STAKES ABOVE TIE TO PREVENT ABRASION TO OTHER BRANCHES.
3. INSTALL BERM ON DOWNSIDE OF SLOPES FOR TREES ON GRADE OF 5:1 OR GREATER.
FINISH GRADE
INERT GROUNDCOVER PER
SCHEDULE
3" DEEP TREE WELL, BLEND TO
GRADING
BACKFILL WITH SITE AMENDED
SOIL AND WATER SETTLE
HOLE SIZE: 2X WIDTH OF
ROOTBALL
LOOSEN SOIL 3X WIDTH OF
ROOTBALL
SIDES OF PLANT PIT SHALL BE
SCARIFIED AND SLOPING
2" DIA. PRESSURE TREATED 8'-0"
LODGEPOLE PINE TREE STAKES
(SEE NOTE 2)
CL
12" MIN.
18" MAX.
TOP OF DECOMPOSED GRANITE
FINISH GRADE
3" DEEP TREE WELL, BLEND TO
FINAL GRADE
BACKFILL WITH SITE AMENDED
SOIL AND WATER SETTLE
HOLE SIZE: 2X WIDTH OF
ROOTBALL. LOOSEN SOIL 3X
WIDTH OF ROOTBALL. WATER
SETTLE. BACKFILL HOLE
SIDES OF PLANT PIT SHALL BE
SCARIFIED AND SLOPING
2" DIA. PRESSURE TREATED 8'-0"
LODGEPOLE PINE TREE STAKES.
(SEE NOTE 2)
MULTI-TRUNK TREE PLANTING
SCALE: NTS
30"
PREVAILING WIND
120°
120°
NOTES:
1. SET TOP OF ROOTBALL 4'' BELOW TOP OF TREE WELL. ORGANIC MULCH AS REQUIRED.
2. DRIVE TREE STAKES 3' MIN. INTO GROUND TO FIRM BEARING, TAKE CARE NOT TO DAMAGE
ROOTBALL. SAW STAKES ABOVE TIE TO PREVENT ABRASION TO OTHER BRANCHES.
3. INSTALL BERM ON DOWNSIDE OF SLOPES FOR TREES ON GRADE OF 5:1 OR GREATER.
3' MIN.
5' MAX.
1X 2X
3"
ADD ALT 5
IRRIGATION DETAILS
L4.2
DECEMBER 20, 2024
CI
TY
O F
TU
CS
ON
OC
HO
A
PA
RK
IM
PR
OV
EM
EN
TS
N
. F
AI
RV
IE
W S
TR
EE
T, T
UC
SO
N
AZ
Parks & Recreation Capital Planning & Development Unit
R
03.03.23 30% CD
07.10.23 75% CD
418 NORTH TOOLE AVENUE
TUCSON, AZ 85701
P 520.622.9565
12.15.23 100% CD
TD-DEV-1223-00487
100% CD
12 .20 .24
02.23.24
100% CD03.07.24
IFC SET12.20.24
ASSEMBLY
MULTI-OUTLET EMITTER 44REVISED:
STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.
REVISED:
STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.
IRRIGATION TRENCHING
REVISED:
STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.
LATERAL END CAP
TREES
EMITTER LOCATION 45
REVISED:
STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.
DEPTH
REVISED:
STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.
ROTOR
SPRIKLER HEAD
ADD ALT 8, 9, AND 10
| Sheets and Views |
| Ochoa-1-C-L1.0 |
| Ochoa-1-C-L1.1 |
| Ochoa-2-H-L2.1 |
| Ochoa-2-H-L2.2 |
| Ochoa-3-I-L3.1 |
| Ochoa-3-I-L3.2 |
| Ochoa-4-LD-L4.1 |
| Ochoa-4-LD-L4.2 |
File details come from the government source that posted it. Updated .