IFB_250103_Ochoa_Plan_Set.pdf

PDF 13 MB Posted

Attached to
Jacobs Park & Ochoa Soccer Complex Improvements
Solicitation number
250103
Issued by
Pima County, Tucson City, Arizona

About this file

This document is a comprehensive development package for the Ochoa Park Improvements project by the City of Tucson Parks & Recreation Department, located at 3300 N. Fairview Street in Tucson, Arizona. The project involves renovating an existing soccer complex, including upgrading three soccer fields with new LED lighting, irrigation systems, and infrastructure improvements. The project includes a base bid for renovating existing walking paths, adding trees, and installing drip irrigation, with multiple additional alternates that cover items such as post and cable fencing, new irrigation turf rotors for Fields 1, 2, and 3, and other site enhancements. The design documents are dated December 20, 2024, with previous design stages completed between March 2023 and March 2024, indicating a multi-phase development process.

The project is subject to the Build America Buy America Act, requiring contractors to understand and comply with regulations regarding material procurement. The development package includes detailed civil, landscape, and irrigation plans, with specific notes about reclaimed water usage, irrigation system design, and landscape maintenance requirements. The site includes multiple soccer fields, surrounding landscape areas, and provisions for future improvements. Additional alternates allow the city flexibility in scope, with options to add or modify specific elements of the park improvements. The project emphasizes sustainable design practices, including water conservation through efficient irrigation systems and the use of native and drought-tolerant plant species.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DEVELOPMENT PACKAGE

OCHOA PARK

CITY OF TUCSON

3300 N. FAIRVIEW STREET

PRINCE RD

MIRACLE MILE

RODGER RD

FA

IR

VI

EW

A

VE

N F

AI

R

VI

EW

A

VE

IMPROVEMENTS

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\S

HE

ET

S

IF

C\

8- C1

.0_

CO

VE

R_

2-

IF

C.

DW

G

PL

OT

TE

D:

/20 /20

:16 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

100% CD03.07.24

IFC SET12.20.24

(2) EXISTING 2" RECLAIMED

WATER METERS TO REMAIN

IN PLACE. COORDINATE WITH

COT PM PRIOR TO WORK.

PB

PBPB

PB

PB

PB

PB PB PB

PB

PB

15 15 15 151515

08 08

08 08

08 08

15 15

151515

08 08

15 15 15 15

N O

R T

H F

A

IR

V

IE

W A

V E

N U

E

N O

R T

H F

A

IR

V

IE

W A

V E

N U

E

PR

OP

ER

TY

LI

NE

PR

OP

ER

TY

LI

NE

PROPERTY LINE

PR

OP

ER

TY

LI

NE

PR

OP

ER

TY

LI

NE

PROPERTY LINE

NORTH

FIELD 3 UPGRADED LIGHTING TO LED AND UPGRADED INFRASTRUCTURE FOR FIELD 1 AND 2.

CONTRACTOR SHALL INSTALL LED LIGHTING PER ELECTRICAL PLANS. ALL ELECTRICAL OUTAGES AND HOOK UP REQUIREMENTS

SHALL BE COORDINATED WITH THE CITY OF TUCSON.

C1.0A

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

ADDITIONAL ALTERNATES

PLAN

ADD ALTERNATE OVERVIEW

SCALE: 1" = 50'

ADDITIONAL ALTERNATIVE #1

N

FA

IR

VI

EW

FIELD 1 AND 2 UPGRADED LIGHTING TO LED

CONTRACTOR SHALL INSTALL LED LIGHTING PER ELECTRICAL PLANS. ALL ELECTRICAL OUTAGES AND HOOK UP REQUIREMENTS

SHALL BE COORDINATED WITH THE CITY OF TUCSON.

ADDITIONAL ALTERNATIVE #2

OCHOA SOCCER COMPLEX - INSTALL POST AND CABLE FENCING PER THE CONSTRUCTION DOCUMENTS POST AND CABLE FENCE SHALL BE INSTALLED BY CONTRACTOR PER PLANS AT THE LOCATIONS SHOWN ON THE PLAN.

ADDITIONAL ALTERNATIVE #5

OCHOA SOCCER COMPLEX - FIELD 1 NEW IRRIGATION TURF ROTORS

CONTRACTOR SHALL REMOVE AND RETURN EXISTING TURF ROTORS TO CITY OF TUCSON PM. CONTRACTOR SHALL INSTALL NEW ROTORS AND SWING ARM ASSEMBLIES PER THE PLAN AND MANUFACTURER RECOMMENDATIONS.

ADDITIONAL ALTERNATIVE #8

OCHOA SOCCER COMPLEX - FIELD 2 NEW IRRIGATION TURF ROTORS

CONTRACTOR SHALL REMOVE AND RETURN EXISTING TURF ROTORS TO CITY OF TUCSON PM. CONTRACTOR SHALL INSTALL NEW ROTORS AND SWING ARM ASSEMBLIES PER THE PLAN AND MANUFACTURER RECOMMENDATIONS.

ADDITIONAL ALTERNATIVE #9

OCHOA SOCCER COMPLEX - FIELD 3 NEW IRRIGATION TURF ROTORS

CONTRACTOR SHALL REMOVE AND RETURN EXISTING TURF ROTORS TO CITY OF TUCSON PM. CONTRACTOR SHALL INSTALL NEW ROTORS AND SWING ARM ASSEMBLIES PER THE PLAN AND MANUFACTURER RECOMMENDATIONS.

ADDITIONAL ALTERNATIVE #10

ADD ALT 9ADD ALT 8

ADD ALT 2

ADD ALT 2

ADD ALT 2

ADD ALT 2

ADD ALT 2

ADD ALT 2

ADD ALT 2

ADD ALT 2

ADD ALT 10

ADD ALT 1

ADD ALT 1

ADD ALT 1

ADD ALT 1

ADD ALT 1

ADD ALT 5

ADD ALT 5

ADD ALT 5

1. CONTRACTOR IS TO PROVIDE PRICING IN BID SCHEDULE FOR ADDITIONAL ALTERNATIVES.

2. CONTRACTOR SHALL REQUEST CLARIFICATION ON ANY ADDITIONAL ALTERNATIVES DURING THE BIDDING PROCESS. ALL

QUESTIONS SHALL BE DIRECTED TO THE CITY OF TUCSON PROCUREMENT MANAGER.

3. ADDITIONAL ALTERNATIVES #1-2, #5 AND #8-10 ARE PART OF THE OCHOA PARK SCOPE OF WORK. ADDITIONAL

ALTERNATIVES #3, #4, #6 AND #7 ARE FOR JACOBS PARK.

ADDITIONAL ALTERNATIVE NOTES:

1. OCHOA SOCCER COMPLEX: RENOVATE EXISTING WALKING PATH, ADD TREES AND DRIP IRRIGATION

BASE BID:

FIELD 2FIELD 1

FIELD 3

1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT. CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH REGULATIONS. CONTRACTOR SHALL ASK ALL QUESTIONS REGARDING PROCUREMENT OF MATERIALS OR COMPLIANCE WITH THE BUILD AMERICA BUY AMERICA ACT DURING THE BIDDING

PROCESS.

BUILD AMERICA BUY AMERICA ACT

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C1

.X _N

OT

E_

2.D W

G

PL

OT

TE

D:

/20 /20

:14 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

VA

VA

VA

VA

C2.1 C3.1 C4.1 C5.1 C6.1

C2.2 C3.2 C4.2 C5.2 C6.2

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C1

.X _K

EY

M_

2.D W

G

PL

OT

TE

D:

/20 /20

:15 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

REMOVAL NOTES

N F

AI

R

VI

EW

A

VE

REFERENCE NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C2

.X _D

EM

O_

2.D W

G

PL

OT

TE

D:

/20 /20

:15 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

REMOVAL NOTES

F

AI

R

VI

EW

A

VE

REFERENCE NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\S

HE

ET

S

IF

C\

8- C2

.X _D

EM

O_

2-

IF

C.

DW

G

PL

OT

TE

D:

/20 /20

:16 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

PB

PB PB PB

PB

PB

CONSTRUCTION NOTES

N F

AI

R

VI

EW

A

VE

GENERAL NOTES

REFERENCE NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C3

.X _S

IT

E_

2.D W

G

PL

OT

TE

D:

/20 /20

:15 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

CONSTRUCTION NOTES

F

AI

R

VI

EW

A

VE

GENERAL NOTES

REFERENCE NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\S

HE

ET

S

IF

C\

8- C3

.X _S

IT

E_

2-

IF

C.

DW

G

PL

OT

TE

D:

/20 /20

:16 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

PB PB PB

PB

PB

N F

AI

R

VI

EW

A

VE

LEGEND

GENERAL NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C4

.X _G

RA

D_

2.D W

G

PL

OT

TE

D:

/20 /20

:15 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

PBPB

PB

N F

AI

R

VI

EW

A

VE

LEGEND

GENERAL NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C4

.X _G

RA

D_

2.D W

G

PL

OT

TE

D:

/20 /20

:15 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

100% CD03.07.24

REFERENCE NOTES

PB PB PB

PB

PB

CONSTRUCTION NOTES

N F

AI

R

VI

EW

A

VE

REFERENCE NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C5

.X _U

TI

L_

2.D W

G

PL

OT

TE

D:

/20 /20

2:

P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

PB

CONSTRUCTION NOTES

N F

AI

R

VI

EW

A

VE

REFERENCE NOTES

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C5

.X _U

TI

L_

2.D W

G

PL

OT

TE

D:

/20 /20

2:

P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

PB PB PB

PB

PB

N F

AI

R

VI

EW

A

VE

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C6

.X _H

OR

Z_

2.D W

G

PL

OT

TE

D:

/20 /20

:16 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

PB

N F

AI

R

VI

EW

A

VE

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C6

.X _H

OR

Z_

2.D W

G

PL

OT

TE

D:

/20 /20

:16 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

RESERVED

PARKING

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

R T:

\20

\10

8_

CI

TY

_O

F_

TU

CS

ON

_J

AC

OB

S_

PA

RK

\C

AD

\23

8- C7

.X _D

ET

L_

2.D W

G

PL

OT

TE

D:

/20 /20

:16 P

M

TD-DEV-1223-00487

03.03.23 30% CD

07.10.23 75% CD

12.15.23 100% CD

100% CD02.23.24

1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT

NECESSARY TO INSTALL THE IMPROVEMENTS SHOWN ON THE PLANS.

2. ALL PIPING AND FITTINGS AND EQUIPMENT SHALL BE PURPLE IN COLOR,

IDENTIFYING RECLAIMED WATER AND INSTALLED PER THE RECLAIMED WATER

NOTES ON THIS SHEET. "RECLAIMED WATER" TAPE (LABEL FACING UP) TO BE

BURIED WITH PIPING IN TRENCHES.

3. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONDUCT A THOROUGH SITE

INSPECTION AND REVIEW OF THE PROJECT CONSTRUCTION DOCUMENTS INCLUDING

BUT NOT LIMITED TO THE FOLLOWING: LANDSCAPE PLAN, CIVIL PLAN, ELECTRICAL

PLAN, GRADING PLAN AND ALL OTHER ASSOCIATED PLANS THAT EFFECT THIS WORK

PRIOR TO BEGINNING CONSTRUCTION. IF THE CONTRACTOR OBSERVES ANY

DISCREPANCIES AMONG THE CONSTRUCTION DOCUMENTS AND THE EXISTING

CONDITIONS ON SITE, IT IS THEIR RESPONSIBILITY TO CONTACT THE CITY OF

TUCSON PROJECT MANAGER IMMEDIATELY.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SURVEYING, STAKING AND GENERAL

LAYOUT REQUIREMENTS AS NEEDED TO CONSTRUCT THE PROJECT.

5. THE CONTRACTOR SHALL COORDINATE AS NECESSARY WITH THE CITY OF TUCSON

PROJECT MANAGER FOR SUCCESSFUL COMPLETION OF THIS WORK. ALL WORK IS

SUBJECT TO COORDINATION WITH THE CITY OF TUCSON PROJECT MANAGER. NO

WORK MAY BEGIN WITHOUT EXPRESSED WRITTEN CONSENT FROM CITY OF TUCSON

PROJECT MANAGER. CONTRACTOR SHALL ALSO SCHEDULE WORK SO AS TO

MINIMIZE UTILITY DOWN TIMES AND NOTIFY CITY OF TUCSON PROJECT MANAGER 48

HOURS IN ADVANCE OF ANY UTILITY SHUTDOWNS. CONTRACTOR SHALL PROVIDE

PROJECT SCHEDULE AT PRE-CONSTRUCTION MEETING.

6. THE CONTRACTOR SHALL CONFORM TO ALL LOCAL AND STATE REGULATIONS AND

INSTALL THE IRRIGATION SYSTEM AND ITS COMPONENTS PER THE MANUFACTURER'S

SPECIFICATIONS. THE CONTRACTOR SHALL OBTAIN AND PROVIDE PAYMENT FOR ALL

PERMITS REQUIRED BY ANY LOCAL AND STATE AGENCIES AND UTILITY COMPANIES

HAVING JURISDICTION OVER THIS SITE.

DETAILSYM. DESCRIP. MFR. MODEL NO. COMMENTS

IRRIGATION GENERAL NOTES (CONTINUED)

IRRIGATION SCHEDULE

SHEET

LARGE AREA

TURF ROTOR

46'

Hunter I-40-04-SSR-08 Turf Rotor, 4" Pop-Up. Adjustable to Full Circle.

Drain Check Valve, Stainless Steel Riser, 1" Female NPT Inlet Threads, Standard Nozzle.

RECLAIMED WATER NOTES

1. WHEN RECLAIMED WATER WILL BE USED IN AN IRRIGATION SYSTEM, ALL COMPONENTS,

SIGNAGE, SEPARATIONS, REQUIREMENTS FOR DYE TESTING AND MARKING

REQUIREMENTS SHALL CONFORM TO OR EXCEED TUCSON WATER'S RECLAIMED

USER'S MANUAL.

2. ONLY CLASS A+ RECLAIMED WATER, AS DEFINED BY ADEQ WILL BE PROVIDED TO

IRRIGATE LANDSCAPE PLANTS ON THIS PROJECT IN THE AREAS DESIGNATED TO

RECEIVE RECLAIMED WATER.

3. THE CONTRACTOR SHALL PREPARE A WORKER EDUCATION AND SAFETY GUIDELINE

REGARDING THE RISKS ASSOCIATED WITH WORKING WITH CLASS A+ RECLAIMED

WATER. THE WORKERS SHALL BE TRAINED IN THE PROPER PROCEDURES WHEN

WORKING WITH RECLAIMED WATER. VERIFICATION OF THIS TRAINING SHALL BE

SUBMITTED IN WRITING BY THE CONTRACTOR TO THE ENGINEER AT THE

PRE-CONSTRUCTION CONFERENCE, OR A LATER DATE THAT IS ACCEPTABLE TO THE

ENGINEER. THE WORKERS SHALL BE PROVIDED WITH ALL PERSONAL SAFETY

EQUIPMENT AND DEVICES NECESSARY FOR ACCOMPLISHING THE WORK IN

ACCORDANCE WITH OSHA REGULATION 29 CFR PART 1926, CONSTRUCTION SAFETY,

AND HEALTH. THE CONTRACTOR SHALL ALSO ENSURE THAT A “COMPETENT PERSON”

AS DEFINED IN 29 CFR PART 1926, IS PRESENT ON THE JOB AT ALL TIMES WHEN WORK

INVOLVING THE RECLAIMED WATER IS BEING PERFORMED. TRAINING, SAFETY

EQUIPMENT, AND OTHER COSTS ASSOCIATED WITH ENSURING THE HEALTH AND

SAFETY OF THE WORKERS AROUND THE RECLAIMED WATER SHALL BE BOURN BY THE

CONTRACTOR WITHOUT ANY ADDITIONAL EXPENSE TO THE CITY.

4. ANY TANK TRUCK AND OTHER EQUIPMENT THAT IS USED TO DISTRIBUTE RECLAIMED

WATER SHALL BE CLEARLY IDENTIFIED WITH WARNING SIGNS AS MAY BE REQUIRED BY

FEDERAL, STATE, OR LOCAL ORDINANCES.

5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ALL RECLAIMED WATER OUT

OF CONTACT WITH THE PUBLIC. AT NO TIME SHALL THE RECLAIMED WATER BE

ALLOWED TO ESCAPE ONTO THE ROADWAY OR INTO ANY DRAINAGE SYSTEMS.

6. ALL VALVE BOXES, VALVE BOX LIDS, AND REMOTE CONTROL VALVES, AND PVC PIPING

SHALL HAVE THE COLOR PURPLE FOR IDENTIFICATION OF A NON-POTABLE SYSTEM.

ALL PVC PIPE SHALL MEET THE PROVISIONS FOR IDENTIFICATION AS SET FORTH BY

THE ARIZONA STATE DEPARTMENT OF ENVIRONMENTAL QUALITY FOR THE USE OF

RECLAIMED WATER. COLOR IDENTIFICATION SHALL BE PURPLE AND SHALL BE

INTEGRAL WITH THE VALVE BOX AND PIPE MANUFACTURING PROCESS. SITE PAINTED

LIDS SHALL ONLY BE USED WHEN INTEGRALLY COLORED VALVE BOX LIDS OR OTHER

APPURTANCES ARE NOT AVAILABLE. PAINTING MUST RECEIVE PRIOR APPROVAL FROM

THE CITY REPRESENTATIVE.

7. THE CONTRACTOR SHALL COMPLY WITH ALL LAWS, FROM ALL APPROPRIATE

JURISDICTIONS, THAT PERTAIN TO THE CONSTRUCTION, OPERATION, AND

MAINTENANCE OF RECLAIMED WATER DISTRIBUTION SYSTEMS DURING

CONSTRUCTION AND DURING THE ESTABLISHMENT PERIOD. NO ADDITIONAL PAYMENT

SHALL BE MADE TO THE CONTRACTOR FOR CONSTRUCTING THE SYSTEM ACCORDING

TO THESE LAWS.

8. THE IRRIGATION SYSTEM WILL BE OPERATED TO AVOID PONDING OR PUDDLING. TO

MINIMIZE PONDING OR RUNOFF, THE RECLAIMED WATER SHALL BE APPLIED AT A RATE

THAT DOES NOT EXCEED THE INFILTRATION RATE OF THE SOIL.

9. SIGNS READING “CAUTION: RECLAIMED WATER, DO NOT DRINK” SHALL BE

PROMINENTLY DISPLAYED ON THE SITE AND AT ALL ENTRANCES TO THE SITE. IT IS

IMPORTANT TO PLACE THE CAUTION SIGNS AROUND ANY ABOVEGROUND IRRIGATION

EQUIPMENT. THE PURPOSE AND INTENT OF PROPERLY NOTIFYING THE PUBLIC IS TO

ENSURE THAT THE RECLAIMED WATER IS NOT MISUSED.

10. THERE SHALL BE NO CONNECTION BETWEEN THE POTABLE WATER SUPPLY AND ANY

PIPING CONTAINING RECLAIMED WATER.

11. PERSONNEL WORKING IN AND ABOUT THE REUSE SITE SHALL BE INFORMED THAT

RECLAIMED WATER IS BEING USED AND SHALL TAKE APPROPRIATE SAFETY

PRECAUTIONS.

12. RECLAIMED WATER IRRIGATION SYSTEMS ARE SUBJECT TO RESTRICTION IN

CONSTRUCTION THAT THE CONTRACTOR SHALL MAKE HIMSELF AWARE OF ALL

APPLICABLE RESTRICTIONS THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL,

STATE, AND MUNICIPAL CODES REGARDING CONSTRUCTION OF THE RECLAIMED

WATER IRRIGATION DISTRIBUTION SYSTEMS, PARTICULARLY WITH RESPECT TO

WORKER SAFETY, WORKER HYGIENE, WORKER TRAINING AND REQUIRED SEPARATION

DISTANCES BETWEEN ANY RECLAIMED WATER LINE AND ANY POTABLE WATER LINE.

HUNTER 60 psi design pressure.

Lasco T 922-212 Swing Joint Assembly

7. THE CONTRACTOR MUST VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES

PRIOR TO CONSTRUCTION. IF THE CONTRACTOR FAILS TO DO SO AND DAMAGES ANY

UNDERGROUND UTILITIES THROUGH THE COURSE OF HIS WORK THE CONTRACTOR

SHALL PAY FOR ANY REPAIR WORK ASSOCIATED WITH SAID DAMAGES. ALL

UNDERGROUND UTILITY WORK SHALL BE INSPECTED BY THE CITY OF TUCSON PROJECT

MANAGER PRIOR TO BACKFILLING. THIS SHALL INCLUDE, BUT IS NOT LIMITED TO:

IRRIGATION, POTABLE WATER, SEWER, ELECTRICAL AND GAS. CONTRACTOR SHALL

NOTIFY CITY OF TUCSON PROJECT MANAGER WITH A MINIMUM OF 24 HOURS

ADVANCED NOTICE. 48 HOURS IS REQUIRED.

8. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PRESERVE AND

PROTECT EXISTING IMPROVEMENTS, INCLUDING BUT NOT LIMITED TO: ROADS, CURB,

FENCING, LIGHTING, STRUCTURES, UTILITIES, TREES AND IRRIGATION TO REMAIN IN

PLACE. ANY DAMAGED ITEMS WILL BE REPAIRED AND/OR REPLACED AT CONTRACTOR'S

EXPENSE. SHOULD DAMAGE OCCUR, CONTRACTOR SHALL NOTIFY CITY OF TUCSON

PROJECT MANAGER IMMEDIATELY AND PROVIDE AN INCIDENT REPORT.

a. ALL REPAIRS/REPLACEMENTS SHALL REQUIRE WRITTEN SUBMITTAL PERTAINING

TO RELEVANT PRODUCTS, MEANS AND METHODS FOR CITY OF TUCSON PROJECT

MANAGER APPROVAL PRIOR TO INITIATING THE WORK. ALL REPAIRS/

REPLACEMENTS SHALL BE MADE AT THE CONTRACTOR'S EARLIEST OPPORTUNITY

AND SHALL REQUIRE VISUAL INSPECTION AND APPROVAL BY CITY OF TUCSON

PROJECT MANAGER. CITY OF TUCSON PROJECT MANAGER MAY WITHHOLD FINAL

ACCEPTANCE OF THE PROJECT UNTIL SAID ITEMS HAVE BEEN SATISFACTORILY

ADDRESSED.

9. ALL WORK AREAS ASSOCIATED WITH THIS PROJECT SHALL BE PROPERLY SECURED

AND CORDONED OFF TO PREVENT ACCESS FROM THE GENERAL PUBLIC. A MINIMUM 6'

CHAINLINK FENCE IS REQUIRED AT ALL TIMES. CONTRACTOR SHALL PROVIDE A

FENCING PLAN AT PRE-CONSTRUCTION MEETING.

10. THIS FACILITY WILL REMAIN IN OPERATION DURING CONSTRUCTION. CONTRACTOR

SHALL MAINTAIN ADEQUATE AND SAFE PUBLIC INGRESS AND EGRESS TO THE FACILITY

AND ALL ITS AMENITIES NOT DIRECTLY AFFECTED BY CONSTRUCTION FOR THE

DURATION OF THE PROJECT. NO PUBLIC ACCESS SHALL BE RESTRICTED WITHOUT

WRITTEN CONSENT OF CITY OF TUCSON PROJECT MANAGER.

11. IT IS THE INTENT OF THIS DESIGN THAT ALL IRRIGATION EQUIPMENT BE INSTALLED

WITHIN THE PROJECT LIMITS AND WITHIN LANDSCAPE AREAS. ANY EQUIPMENT SHOWN

OUTSIDE OF THESE LIMITS IS SHOWN FOR GRAPHICAL CLARITY ONLY. IF THERE IS A

QUESTION REGARDING THE LOCATION OF ANY COMPONENT OF THE IRRIGATION

SYSTEM, IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE CITY OF TUCSON

PROJECT MANAGER. IF THE CONTRACTOR NEGLECTS TO NOTIFY THE NECESSARY

PARTIES, THE CONTRACTOR SHALL PAY FOR ANY REPLACEMENT OR MODIFICATION TO

ENSURE PROPER LOCATION AND OPERATION OR THE IRRIGATION SYSTEM AND ITS

COMPONENTS.

12. THE CONTRACTOR ASSUMES ALL LIABILITY ASSOCIATED WITH THE MODIFICATION OF

THE IRRIGATION SYSTEM DESIGN WITHOUT NOTIFYING THE CITY OF TUCSON PROJECT

MANAGER.

13. ALL IRRIGATION EQUIPMENT IS TO BE AS SPECIFIED, OR APPROVED EQUAL PER THE

DISCRETION OF THE CITY OF TUCSON PROJECT MANAGER.

IRRIGATION GENERAL NOTES

21 L4.2

14. ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES, INCLUDING TURF AREAS SHALL

BE RESTORED TO THEIR ORIGINAL CONDITION PRIOR TO FINAL ACCEPTANCE.

15 Hunter I-40-04-SSR-15 Turf Rotor, 4" Pop-Up. Adjustable to Full Circle.

Drain Check Valve, Stainless Steel Riser, 1" Female NPT Inlet Threads, Standard Nozzle.

LARGE AREA

TURF ROTOR

55'

HUNTER 60 psi design pressure.

Lasco T 922-212 Swing Joint Assembly

21 L4.2

15. ALL TRENCHES SHALL BE RETURNED TO EXISTING GRADE, CLEARED OF ALL ROCKS

AND MATERIALS GREATER THAN 1". IN TURF AREAS, CONTRACTOR SHALL PROVIDE

MANUALLY BROADCAST SEED FOR REVEGETATION OF MAINLINE TRENCHES AND

OTHER TRENCHES GREATER THAN 6" IN WIDTH AT FINISH GRADE.

16. CONTRACTOR SHALL FINE TUNE AND ADJUST NOZZLE DIRECTION AND RADIUS TO

REDUCE OVER SPRAY ONTO PAVING OR HARD SURFACES, BENCHES, PICNIC TABLES,

WATER FOUNTAINS, ETC.

17. ALL SPRAY IRRIGATION SHALL BE KEPT 18" MINIMUM FROM PUBLIC SIDEWALKS OR

PATHS UNLESS OTHERWISE DIRECTED BY CITY OF TUCSON PROJECT MANAGER.

18. THE TURF IRRIGATION SYSTEM SHALL BE DESIGNED TO APPLY WATER AT THE

FOLLOWING MINIMUM APPLICATION EFFICIENCIES AS MEASURED BY THE LOW

QUARTER DISTRIBUTION UNIFORMITY METHOD AFTER CONSTRUCTION:

· ROTORS 65% DU MEASURED BY AUDIT.

20. THIS IRRIGATION SYSTEM HAS BEEN DESIGNED TO PROVIDE 2" OF WATER DURING AN

EIGHT HOUR PER NIGHT (10 PM TO 6 AM) WATERING WINDOW ON A 6 DAY SCHEDULE TO

ALLOW MOW DAYS. ESTABLISHMENT WATERING WILL REQUIRE ADDITIONAL IRRIGATION

FOR A FOUR TO SIX WEEK PERIOD. COORDINATE SCHEDULE WITH CITY OF TUCSON

PROJECT MANAGER AND IRRIGATOR.

SYMBOL DESCRIPTION DETAIL QTY.

CONCRETE - STANDARD GRAY - MEDIUM

BROOM FINISH 1/L4.1 2,564 SF

EXISTING TURF TO REMAIN -

EXISTING GRASS AREAS ARE TO BE

REPAIRED WHERE NEEDED DUE TO

IRRIGATION TRENCHING OR PROJECT

IMPROVEMENTS. CONTRACTOR IS TO

VERIFY LIMITS OF GRASS RESEEDING WITH

THE COT PROJECT MANAGER PRIOR TO

CONSTRUCTION. GRASS IS TO BE BY

HYDROSTOLON - TIFTUF BERMUDA HYBRID

GRASS OR APPROVED EQUAL.

N/A 298,243 SF

SURFACING SCHEDULE

POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51

HARDSCAPE SCHEDULE

SITE AMENITY NOTES

POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51

HARDSCAPE SCHEDULE

SITE AMENITY NOTES

SYMBOL BOTANICAL / COMMON NAME SIZE QTY

TREES, SEE DETAIL 3/L4.1, 5/L4.1

Ebenopsis ebano Texas Ebony 15 GAL 5

Prosopis seedless hybrid 'Leslie Roy' Leslie Roy Mesquite 15 GAL 23

Existing to Remain

LANDSCAPE SCHEDULE

EMITTER

DRIP LATERAL

EMITTER SCHEDULE

PLANT TYPE

EXISTING TREE

24" BOX TREES

TREE

OUTLET

SYM. DESCRIPTION

IRRIGATION SCHEDULE

NOTES

DETAIL

LARGE AREA TURF ROTOR 57'

HUNTER MPE-20 2 GPH EMITTERS

HUNTER MPE-20 2 GPH EMITTERS

MULTI-OUTLET EMITTER 44, 45 / L4.2

38 / L4.2

1. ALL TREES SHALL BE IRRIGATED WITH HUNTER MPE-20

MULTI-PORT EMITTERS IN 6" ROUND BOX. ALL 24" BOX

TREES TO HAVE MIN. 1 PER TREE.

2. ALL PIPE SHALL BE INSTALLED WITH IDENTIFICATION

TEXT FACING UP IN TRENCH AND MARKED FOR

RECLAIMED WATER USE. ALL EMITTER BOXES TO

HAVE PURPLE LID.

15 21 / L4.2

END CAP 34 / L4.2

NOTES & SCHEDULES

1. ALL REQUIRED LANDSCAPING, IRRIGATION SYSTEMS, WALLS, SCREENING DEVICES, CURBING, AND DETENTION BASIN LANDSCAPE IMPROVEMENTS ON THE SITE OR WITHIN THE ABUTTING

RIGHT-OF-WAY SHALL BE MAINTAINED AS SHOWN ON THE APPROVED PLANS. THE PROPERTY

OWNER IS RESPONSIBLE FOR PROPER MAINTENANCE TO ACHIEVE PERMANENT, SAFE, AND

SUCCESSFUL LANDSCAPING AS REQUIRED BY ARTICLE 7.6.8 OF THE COT UDC.

2. PLANT PRUNING SHOULD BE COMPLETED PER STANDARDS OUTLINED IN ALCA SUSTAINABLE

LANDSCAPE MANAGEMENT MANUAL.THESE INCLUDE BUT ARE NOT LIMITED TO:

· DESERT TREES SHOULD BE PRUNED JUNE-OCTOBER

· DECIDUOUS AND EVERGREEN TREES SHOULD BE PRUNED DECEMBER-JANUARY

· YUCCA AND HESPERALOE SHOULD BE PRUNED SEPTEMBER-NOVEMBER

· GRASSES SHOULD BE PRUNED DECEMBER-FEBRUARY

· FROST SENSITIVE PLANS SHOULD BE PRUNED IN MARCH

· CASIAS AND OTHER DESERT SHRUBS SHOULD BE PRUNED APRIL-MAY

3. THE CONTRACTOR SHALL PROVIDE A SEASONAL MAINTENANCE SCHEDULE WHICH SHALL

BEGIN ON APRIL 1 AND END ON OCTOBER 1 TO ENSURE THE EFFICIENCY AND LONGEVITY OF

THE IRRIGATION SYSTEM. THE MAINTENANCE SCHEDULE SHALL INCLUDE BUT IS NOT LIMITED

TO THE FOLLOWING LIST OF BEST MANAGEMENT PRACTICES:

· CHECK ENTIRE IRRIGATION SYSTEM FOR LEAKS

· VERIFY PROPER OPERATION OF ALL CONTROL VALVES, SPRAY HEADS, AND DRIP EMITTERS.

· ADJUST SPRAY IRRIGATION TO PROVIDE UNIFORM COVERAGE AND NO OVERSPRAY ON

PAVEMENT

· CHECK CONTROLLER PROGRAMMING AND ADJUST FOR SEASONAL CHANGES AS NECESSARY.

· VERIFY THAT THE WATER SUPPLY AND PRESSURE ARE AS STATED IN THE DESIGN.

· CERTIFY THE BACKFLOW PREVENTION DEVICE AND SUBMIT TEST RESULTS TO THE PROPERTY

MANAGER.

· PERIODICALLY VERIFY THE SENSORS IN THE IRRIGATION SYSTEM ARE OPERATING

CORRECTLY.

· IMMEDIATELY SERVICE ANY COMPONENTS THAT ARE NOT OPERATING AS DESIGNED.

· IMMEDIATELY ADDRESS ANY ITEMS THAT VIOLATE REGULATIONS FOR WATER CONSERVATION,

SUCH AS LEAKS, OVER SPRAY, STUCK VALVES, OR IMPROPER PROGRAMMING.

4. THE PROPERTY OWNER IS RESPONSIBLE FOR REPLACEMENT OF ANY PLANT MATERIAL,

SHOULD ANY NOT SURVIVE, AND REPLACEMENT / UPKEEP OF INERT GROUNDCOVERS AND

HARDSCAPE MATERIALS, AS REQUIRED BY ARTICLE 7.6.8 OF THE COT UDC.

L1.1

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

MAINTENANCE SCHEDULE

LANDSCAPE NOTES

1. WRITTEN DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS.

2. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL PLANT QUANTITIES.

3. LOCATION OF ALL ELEMENTS ON THIS PLAN SHALL BE APPROVED BY THE OWNER'S

REPRESENTATIVE OR LANDSCAPE ARCHITECT, PRIOR TO INSTALLATION.

4. ALL DISTURBED, GRUBBED, GRADED, OR BLADED AREAS NOT OTHERWISE IMPROVED SHALL BE

LANDSCAPED, RESEEDED, OR TREATED WITH AN INORGANIC OR ORGANIC GROUNDCOVER.

5. THE SCHEDULE FOR PLANTING OF TREES AND SHRUBS SHALL BE AT THE DISCRETION OF THE

CONTRACTOR. PLANTING DURING EXTREMELY COLD, HOT, OR WINDY PERIODS SHALL BE

PERFORMED AT THE CONTRACTOR'S RISK. PLANTS WHICH ARE DAMAGED OR DIE PRIOR TO

FINAL ACCEPTANCE AS A RESULT OF EXTREME WEATHER CONDITIONS SHALL BE REMOVED

AND REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER.

6. PLANT SIZE, LOCATION, AND SPACING:

· TREES AND SHRUBS ARE TO BE LOCATED SO THAT, AT MATURITY, THEY DO NOT INTERFERE

WITH EXISTING ONSITE OR OFFSITE UTILITY SERVICE LINES OR UTILITY EASEMENTS OR

WITH SOLAR ACCESS TO AN ADJACENT PROPERTY.

· ALL SHRUBS AND GROUNDCOVERS TO BE A MINIMUM OF 3' FROM BACK OF CURB OR BACK

OF SIDEWALK.

7. PLANT PLACEMENT TO BE FIELD ADJUSTED AS NEEDED TO AVOID PROPOSED UTILITIES,

EXISTING PRESERVED VEGETATION, AND OTHER FIELD CONDITIONS. CONTACT THE OWNER'S

REPRESENTATIVE OR LANDSCAPE ARCHITECT FOR RELOCATION OF PLANTS IN QUESTIONABLE

AREAS.

8. FINAL PLANT LOCATIONS MUST BE IN COMPLIANCE WITH ALL UTILITY SETBACK

REQUIREMENTS.

9. THE CONTRACTOR SHALL SCHEDULE UTILITY LOCATION SERVICES AND TAKE EXTREME CARE

WHILE WORKING WITHIN THE PROJECT AREA AS TO NOT DISTURB ANY EXISTING UTILITIES OR

STRUCTURES ON OR ADJACENT TO THE PROJECT AREA. THE CONTRACTOR SHALL BE

RESPONSIBLE FOR REPLACING AND OR REPAIRING ANY EXISTING STRUCTURES OR UTILITIES

DAMAGED DURING CONSTRUCTION AT NO ADDITIONAL COST TO THE OWNER.

10. ALL WORK SHALL BE CONFINED TO THE AREA WITHIN THE PROPERTY LIMITS AS SHOWN ON

THE PLANS. ANY AREAS OR IMPROVEMENTS DISTURBED OUTSIDE THESE LIMITS SHALL BE

REVEGETATED TO THEIR ORIGINAL CONDITION AT THE CONTRACTOR'S EXPENSE. IN THE

EVENT THE CONTRACTOR REQUIRES A MODIFICATION TO THE CONSTRUCTION LIMITS,

WRITTEN PERMISSION MUST BE OBTAINED FROM THE OWNER'S REPRESENTATIVE PRIOR TO

ANY DISTURBANCE OUTSIDE OF THE LIMITS OF WORK.

11. NOTIFY THE OWNER'S REPRESENTATIVE OR LANDSCAPE ARCHITECT 48 HOURS IN ADVANCE OF

ANY INSPECTIONS AND / OR APPROVALS OF LANDSCAPE MATERIAL AND IRRIGATION

PRODUCTS PRIOR TO INSTALLATION.

12. THE CONTRACTOR SHALL WARRANTY THE PLANT MATERIAL, IRRIGATION SYSTEM AND

WORKMANSHIP FOR A MINIMUM PERIOD OF ONE YEAR.

13. ALL TREES ARE TO BE STAKED AND GUYED PER DETAILS FOR A MINIMUM PERIOD OF ONE

YEAR AS NECESSARY OR AT THE DISCRETION OF THE OWNER'S REPRESENTATIVE. THE

CONTRACTOR SHALL REMOVE STAKING AND GUYING PRIOR TO THE FINAL, ONE YEAR WALK

THROUGH.

14. A MINIMUM OF THREE FEET (3') ACCESS TO AND CLEARANCE AROUND ALL FIRE HYDRANTS.

15. ROOT BARRIER TO BE UTILIZED WHERE NECESSARY FOR TREES ADJACENT TO CURBS AND

SIDEWALKS.

ADD ALT 8, 9, AND 10

1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT. CONTRACTOR IS

RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH REGULATIONS. CONTRACTOR

SHALL ASK ALL QUESTIONS REGARDING PROCUREMENT OF MATERIALS OR COMPLIANCE WITH

THE BUILD AMERICA BUY AMERICA ACT DURING THE BIDDING PROCESS.

PB PB PB

PB

PB

N O

R T

H F

A

IR

V

IE

W A

V E

N U

E

PR

OP

ER

TY

LI

NE

PROPERTY LINE

PR

OP

ER

TY

LI

NE

NEW CONCRETE

REPLACEMENT TYP. -

SEE CIVIL PLANS

EXISTING NATURAL TURF TO

REMAIN - CONTRACTOR SHALL

REPAIR ALL TURF DISTURBED

BY CONSTRUCTION ACTIVITIES

EXISTING NATURAL TURF TO

REMAIN - CONTRACTOR SHALL

REPAIR ALL TURF DISTURBED

BY CONSTRUCTION ACTIVITIES

NEW CONCRETE

REPLACEMENT TYP. -

SEE CIVIL PLANS

NEW CONCRETE

REPLACEMENT TYP. -

SEE CIVIL PLANS

NEW CONCRETE NEW CONCRETE

SYMBOL DESCRIPTION DETAIL QTY.

CONCRETE - STANDARD GRAY - MEDIUM

BROOM FINISH 1/L4.1 2,564 SF

EXISTING TURF TO REMAIN -

EXISTING GRASS AREAS ARE TO BE

REPAIRED WHERE NEEDED DUE TO

IRRIGATION TRENCHING OR PROJECT

IMPROVEMENTS. CONTRACTOR IS TO

VERIFY LIMITS OF GRASS RESEEDING WITH

THE COT PROJECT MANAGER PRIOR TO

CONSTRUCTION. GRASS IS TO BE BY

HYDROSTOLON - TIFTUF BERMUDA HYBRID

GRASS OR APPROVED EQUAL.

N/A 298,243 SF

SURFACING SCHEDULE

POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51

HARDSCAPE SCHEDULE

SITE AMENITY NOTES

POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51

HARDSCAPE SCHEDULE

SITE AMENITY NOTES

SYMBOL BOTANICAL / COMMON NAME SIZE QTY

TREES, SEE DETAIL 3/L4.1, 5/L4.1

Ebenopsis ebano Texas Ebony 15 GAL 5

Prosopis seedless hybrid 'Leslie Roy' Leslie Roy Mesquite 15 GAL 23

Existing to Remain

LANDSCAPE SCHEDULE

HARDSCAPE & LANDSCAPE

PLAN

L2.1

MATCHLINE - SEE SHEET L2.2

KEY MAP

N.

F

AI

RV

IE

W

A

VE

SHEET L2.1

SHEET L3.1

SHEET L2.2

SHEET L3.2

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

NORTH

0 3015 60

SCALE 1" = 30'

1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT.

CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH

REGULATIONS. CONTRACTOR SHALL ASK ALL QUESTIONS REGARDING

PROCUREMENT OF MATERIALS OR COMPLIANCE WITH THE BUILD AMERICA BUY

AMERICA ACT DURING THE BIDDING PROCESS.

PB

PB PB

N O

R T

H F

A

IR

V

IE

W A

V E

N U

E

PR

OP

ER

TY

LI

NE

PR

OP

ER

TY

LI

NE

PROPERTY LINE

EXISTING DG

TO REMAIN

NEW CONCRETE

REPLACEMENT TYP. -

SEE CIVIL PLANS

LOW WATER

CROSSING - SEE

CIVIL PLANS

PLAYGROUND

RENOVATION

UNDER

SEPARATE

PERMIT

S.V.T.

S.V.T.

EXISTING NATURAL TURF TO

REMAIN - CONTRACTOR SHALL

REPAIR ALL TURF DISTURBED

BY CONSTRUCTION ACTIVITIES

CONTRACTOR TO COORDINATE THE FOLLOWING REPAIRS

WITH OWNER'S REPRESENTATIVE PRIOR TO CONSTRUCTION:

REPLACE DRIP EDGE AND PAINT COLOR TO MATCH EXISTING,

REPLACE RESTROOM DOORS, REPAIR STEEL DIVIDER WITH

WELD STEEL PLATE AND PAINT TO MATCH EXISTING, REPLACE

EXTERIOR LIGHTS UNDER ROOF EVES WITH LED FIXTURES.

CONTRACTOR SHALL VERIFY

HORIZONTAL AND VERTICAL

LOCATION OF SEPTIC

SYSTEM LEACH FIELD AND

APPURTENANCES PRIOR TO

CONSTRUCTION AND

PROTECT IN PLACE

CONTRACTOR TO

RAKE DG BACK

AFTER TREE

INSTALLATION

CONTRACTOR TO RAKE DG BACK

AFTER TREE INSTALLATION

CONTRACTOR TO

RAKE DG BACK

AFTER TREE

INSTALLATION

NEW CONCRETE

REPLACEMENT

TYP. - SEE CIVIL

PLANS

NEW CONCRETE

REPLACEMENT

TYP. - SEE CIVIL

PLANS

NEW CONCRETE

REPLACEMENT

TYP. - SEE CIVIL

PLANS

NEW CONCRETE

REPLACEMENT

TYP. - SEE CIVIL

PLANS

REPLACE ADA

RAMP AND CURB -

SEE CIVIL PLANS

NEW CONCRETE

REPLACEMENT

TYP. - SEE CIVIL

PLANS

NEW CONCRETE

REPLACEMENT

TYP. - SEE CIVIL

PLANS

TRASH ENCLOSURE

- SEE CIVIL PLANS

CONTRACTOR

SHALL

COORDINATE

LWCF SIGN

INSTALLATION

WITH COT PM

ADD ALT 5

ADD ALT 5

ADD

ALT 5

SYMBOL DESCRIPTION DETAIL QTY.

CONCRETE - STANDARD GRAY - MEDIUM

BROOM FINISH 1/L4.1 2,564 SF

EXISTING TURF TO REMAIN -

EXISTING GRASS AREAS ARE TO BE

REPAIRED WHERE NEEDED DUE TO

IRRIGATION TRENCHING OR PROJECT

IMPROVEMENTS. CONTRACTOR IS TO

VERIFY LIMITS OF GRASS RESEEDING WITH

THE COT PROJECT MANAGER PRIOR TO

CONSTRUCTION. GRASS IS TO BE BY

HYDROSTOLON - TIFTUF BERMUDA HYBRID

GRASS OR APPROVED EQUAL.

N/A 298,243 SF

SURFACING SCHEDULE

POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51

HARDSCAPE SCHEDULE

SITE AMENITY NOTES

POST AND CABLE BARRIER, SEE DETAIL 2/L4.1 - ADD ALT #51

HARDSCAPE SCHEDULE

SITE AMENITY NOTES

SYMBOL BOTANICAL / COMMON NAME SIZE QTY

TREES, SEE DETAIL 3/L4.1, 5/L4.1

Ebenopsis ebano Texas Ebony 15 GAL 5

Prosopis seedless hybrid 'Leslie Roy' Leslie Roy Mesquite 15 GAL 23

Existing to Remain

LANDSCAPE SCHEDULE

HARDSCAPE & LANDSCAPE

PLAN

L2.2

30% CD

MATCHLINE - SEE SHEET L2.1

KEY MAP

N.

F

AI

RV

IE

W

A

VE

SHEET L2.1

SHEET L3.1

SHEET L2.2

SHEET L3.2

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

NORTH

0 3015 60

SCALE 1" = 30'

1. THIS PROJECT MUST ADHERE TO THE BUILD AMERICA BY AMERICA ACT.

CONTRACTOR IS RESPONSIBLE FOR UNDERSTANDING AND COMPLYING WITH

REGULATIONS. CONTRACTOR SHALL ASK ALL QUESTIONS REGARDING

PROCUREMENT OF MATERIALS OR COMPLIANCE WITH THE BUILD AMERICA BUY

AMERICA ACT DURING THE BIDDING PROCESS.

08 08

15 15

08 08

15 15 15 15

LIMIT OF

WORK

LIMIT OF

WORK

LIMIT OF

WORK

ADD ALT #8 - FIELD LOCATE & REPLACE

EXISTING ROTORS WITH HUNTER

I-40-04-SS-R (NOZZLE PER PLAN) AND LASCO

T 922-212 SWING JOINTS

ADD ALT #9 - FIELD LOCATE & REPLACE

EXISTING ROTORS WITH HUNTER

I-40-04-SS-R (NOZZLE PER PLAN) AND LASCO

T 922-212 SWING JOINTS

N O

R T

H F

A

IR

V

IE

W A

V E

N U

E

PR

OP

ER

TY

LI

NE

PROPERTY LINE

PR

OP

ER

TY

LI

NE

CONTRACTOR TO LOCATE AND CONFIRM

WORKING CONDITION OF EXISTING

LATERALS. CONNECT TO AND EXTEND

LATERALS TO NEW TREES.

CONTRACTOR TO LOCATE AND

CONFIRM WORKING CONDITION

OF EXISTING LATERALS.

CONNECT TO AND EXTEND

LATERALS TO NEW TREES.

CONTRACTOR TO LOCATE AND CONFIRM WORKING

EMITTER

DRIP LATERAL

EMITTER SCHEDULE

PLANT TYPE

EXISTING TREE

24" BOX TREES

TREE

OUTLET

SYM. DESCRIPTION

IRRIGATION SCHEDULE

NOTES

DETAIL

LARGE AREA TURF ROTOR 57'

HUNTER MPE-20 2 GPH EMITTERS

HUNTER MPE-20 2 GPH EMITTERS

MULTI-OUTLET EMITTER 44, 45 / L4.2

38 / L4.2

1. ALL TREES SHALL BE IRRIGATED WITH HUNTER MPE-20

MULTI-PORT EMITTERS IN 6" ROUND BOX. ALL 24" BOX

TREES TO HAVE MIN. 1 PER TREE.

2. ALL PIPE SHALL BE INSTALLED WITH IDENTIFICATION

TEXT FACING UP IN TRENCH AND MARKED FOR

RECLAIMED WATER USE. ALL EMITTER BOXES TO

HAVE PURPLE LID.

15 21 / L4.2

END CAP 34 / L4.2

ADD ALT BOUNDARY

IRRIGATION PLAN

L3.1

KEY MAP

N.

F

AI

RV

IE

W

A

VE

SHEET L3

SHEET L5

SHEET L7

SHEET L4

SHEET L6

SHEET L8

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

MATCHLINE - SEE SHEET L3.2

CONTRACTOR IS TO REPLACE ALL IRRIGATION ROTORS

INCLUDING THE SWING ARM ASSEMBLY. ADJUST HEAD

INSTALLATION DEPTH AS NEEDED PER DETAIL 5, SHEET

L4.1. ADJUSTMENT OF HEAD LOCATIONS TO BE

PROVIDED ONLY AT DIRECTION OF CITY OF TUCSON PM.

ALL TURF DAMAGED DURING TRENCHING AND

CONSTRUCTION ACTIVITIES SHALL BE REPAIRED USING

HYDROSTOLONS.

NORTH

0 3015 60

SCALE 1" = 30'

EMITTER

DRIP LATERAL

EMITTER SCHEDULE

PLANT TYPE

EXISTING TREE

24" BOX TREES

TREE

OUTLET

SYM. DESCRIPTION

IRRIGATION SCHEDULE

NOTES

DETAIL

LARGE AREA TURF ROTOR 57'

HUNTER MPE-20 2 GPH EMITTERS

HUNTER MPE-20 2 GPH EMITTERS

MULTI-OUTLET EMITTER 44, 45 / L4.2

38 / L4.2

1. ALL TREES SHALL BE IRRIGATED WITH HUNTER MPE-20

MULTI-PORT EMITTERS IN 6" ROUND BOX. ALL 24" BOX

TREES TO HAVE MIN. 1 PER TREE.

2. ALL PIPE SHALL BE INSTALLED WITH IDENTIFICATION

TEXT FACING UP IN TRENCH AND MARKED FOR

RECLAIMED WATER USE. ALL EMITTER BOXES TO

HAVE PURPLE LID.

15 21 / L4.2

END CAP 34 / L4.2

ADD ALT BOUNDARY

15 15 15 151515

08 08

08 08

08 08

151515

LIMIT OF WORK

LIMIT OF

WORK

LIMIT OF

WORK

(3) EXISTING 2"

RECLAIMED WATER

METERS TO

REMAIN IN PLACE.

ADD ALT #10 - FIELD LOCATE & REPLACE

EXISTING ROTORS WITH HUNTER

I-40-04-SS-R (NOZZLE PER PLAN) AND LASCO

T 922-212 SWING JOINTS

N O

R T

H F

A

IR

V

IE

W A

V E

N U

E

PR

OP

ER

TY

LI

NE

PR

OP

ER

TY

LI

NE

PROPERTY LINE

LIMIT OF

WORK

CONTRACTOR TO LOCATE AND

CONFIRM WORKING CONDITION

OF EXISTING LATERALS.

CONNECT TO AND EXTEND

LATERALS TO NEW TREES.

CONTRACTOR TO LOCATE AND

CONFIRM WORKING CONDITION

OF EXISTING LATERALS.

CONNECT TO AND EXTEND

LATERALS TO NEW TREES.

CONTRACTOR TO LOCATE AND

CONFIRM WORKING CONDITION

OF EXISTING LATERALS.

CONNECT TO AND EXTEND

LATERALS TO NEW TREES.

CONTRACTOR TO

LOCATE AND CONFIRM

WORKING CONDITION OF

EXISTING LATERALS.

CONNECT TO AND

EXTEND LATERALS TO

NEW TREES.

CONTRACTOR TO LOCATE AND CONFIRM WORKING

CONDITION OF EXISTING LATERALS. CONNECT TO

AND EXTEND LATERALS TO NEW TREES.

IRRIGATION PLAN

L3.2

KEY MAP

N.

F

AI

RV

IE

W

A

VE

SHEET L3

SHEET L5

SHEET L7

SHEET L4

SHEET L6

SHEET L8

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

MATCHLINE - SEE SHEET L3MATCHLINE - SEE SHEET L3.1

CONTRACTOR IS TO REPLACE ALL IRRIGATION ROTORS

INCLUDING THE SWING ARM ASSEMBLY. ADJUST HEAD

INSTALLATION DEPTH AS NEEDED PER DETAIL 5, SHEET

L4.1 . ADJUSTMENT OF HEAD LOCATIONS TO BE

PROVIDED ONLY AT DIRECTION OF CITY OF TUCSON PM.

ALL TURF DAMAGED DURING TRENCHING AND

CONSTRUCTION ACTIVITIES SHALL BE REPAIRED USING

HYDROSTOLONS.

NORTH

0 3015 60

SCALE 1" = 30'

LANDSCAPE DETAILS

L4.1

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

1 2

4" THICK CONCRETE PAVING

FINISH AS NOTED ON HARDSCAPE

PLANS - 3,000 PSI AT 28 DAYS

TOOLED JOINT, 1/4" RADIUS

SPACE EQUAL TO WIDTH OF

WALK UNLESS NOTED

OTHERWISE. DEPTH TO 1" MIN.

FIBER EXPANSION JOINT WITH

TRAFFIC SEALANT

SAW CUT JOINT, 1/4" X 2" DEPTH.

DRY CUT JOINT TO AVOID

SPALLING. JOINTS SHALL BE CUT

BETWEEN 24-48 HOURS OF

INSTALLATION

1/2" RADIUS TOOL EDGE

FINISH GRADE

ROCK SURFACING PER

LANDSCAPE PLAN

PREPARED SUBGRADE PER

GEOTECH RECOMMENDATIONS,

95% COMPACTED SUBGRADE

CONCRETE

SCALE: NTS

4" 2" 1"

2 1 3 4 5 6

NOTE:

1. C.I.P. CONCRETE PER PLANS AND SPECS. SPACE CONTROL JOINTS THE WIDTH OF THE

WALK OR AS SHOWN ON PLANS WITH EXPANSION JOINTS @ 10' O.C. MAX. OR WHERE

NOTED.

2. EXPANSION JOINTS @ ALL CONSTRUCTION JOINTS, SLAB EDGES OF ALL STRUCTURES

3. USE 16P NAILS THROUGH EXPANSION JOINT MATERIAL @ 12" O.C. TO HOLD MATERIAL IN

PLACE.

4. CONCRETE SLABS NOT TO EXCEED 300 SQ. FT. WITHOUT AN EXPANSION JOINT.

5. PROVIDE A 1" REVEAL FOR ALL ADJACENT GROUND PLANE TREATMENTS.

3 4

END PIPE: 4" DIAMETER

SCHEDULE 40 PIPE

MID PIPE: 4" DIAMETER

SCHEDULE 40 PIPE

MALLEABLE STEEL CAP - TACK

WELD TO POST

CONCRETE FOOTER

SLOPE TO DRAIN

4" HOLE

2" DIA. (6x25) GALVANIZED STEEL

WIRE ROPE CABLE - MINIMIZE

SAG

AT ENDS, LOOP CABLE & FASTEN

WITH 3 CABLE CLAMPS

FINISH GRADE

POST AND CABLE BARRIER

SCALE: 1" = 1'-0"

3'-0"

12'-0" O.C. MAX.

3"

1'-4"

1'-0"

4"

NOTE:

1. GRIND SMOOTH WELDS.

2. PRIME ALL POSTS WITH RUST

INHIBITING PAINT. COLOR :

HYPER BLUE - SW 6965

3. ALL CONCRETE SHALL HAVE A

MIN. COMPRESSIVE STRENGTH

OF 3,000 PSI. AT 28 DAYS.

4" 4"

SINGLE-TRUNK TREE PLANTING

SCALE: NTS

3' MIN.

5' MAX.

1X 2X

3"

30"

NOTES:

1. SET TOP OF ROOTBALL 4'' BELOW TOP OF TREE WELL. ORGANIC MULCH AS REQUIRED.

2. DRIVE TREE STAKES 3' MIN. INTO GROUND TO FIRM BEARING, TAKE CARE NOT TO DAMAGE

ROOTBALL. SAW STAKES ABOVE TIE TO PREVENT ABRASION TO OTHER BRANCHES.

3. INSTALL BERM ON DOWNSIDE OF SLOPES FOR TREES ON GRADE OF 5:1 OR GREATER.

FINISH GRADE

INERT GROUNDCOVER PER

SCHEDULE

3" DEEP TREE WELL, BLEND TO

GRADING

BACKFILL WITH SITE AMENDED

SOIL AND WATER SETTLE

HOLE SIZE: 2X WIDTH OF

ROOTBALL

LOOSEN SOIL 3X WIDTH OF

ROOTBALL

SIDES OF PLANT PIT SHALL BE

SCARIFIED AND SLOPING

2" DIA. PRESSURE TREATED 8'-0"

LODGEPOLE PINE TREE STAKES

(SEE NOTE 2)

CL

12" MIN.

18" MAX.

TOP OF DECOMPOSED GRANITE

FINISH GRADE

3" DEEP TREE WELL, BLEND TO

FINAL GRADE

BACKFILL WITH SITE AMENDED

SOIL AND WATER SETTLE

HOLE SIZE: 2X WIDTH OF

ROOTBALL. LOOSEN SOIL 3X

WIDTH OF ROOTBALL. WATER

SETTLE. BACKFILL HOLE

SIDES OF PLANT PIT SHALL BE

SCARIFIED AND SLOPING

2" DIA. PRESSURE TREATED 8'-0"

LODGEPOLE PINE TREE STAKES.

(SEE NOTE 2)

MULTI-TRUNK TREE PLANTING

SCALE: NTS

30"

PREVAILING WIND

120°

120°

NOTES:

1. SET TOP OF ROOTBALL 4'' BELOW TOP OF TREE WELL. ORGANIC MULCH AS REQUIRED.

2. DRIVE TREE STAKES 3' MIN. INTO GROUND TO FIRM BEARING, TAKE CARE NOT TO DAMAGE

ROOTBALL. SAW STAKES ABOVE TIE TO PREVENT ABRASION TO OTHER BRANCHES.

3. INSTALL BERM ON DOWNSIDE OF SLOPES FOR TREES ON GRADE OF 5:1 OR GREATER.

3' MIN.

5' MAX.

1X 2X

3"

ADD ALT 5

IRRIGATION DETAILS

L4.2

DECEMBER 20, 2024

CI

TY

O F

TU

CS

ON

OC

HO

A

PA

RK

IM

PR

OV

EM

EN

TS

N

. F

AI

RV

IE

W S

TR

EE

T, T

UC

SO

N

AZ

Parks & Recreation Capital Planning & Development Unit

R

03.03.23 30% CD

07.10.23 75% CD

418 NORTH TOOLE AVENUE

TUCSON, AZ 85701

P 520.622.9565

12.15.23 100% CD

TD-DEV-1223-00487

100% CD

12 .20 .24

02.23.24

100% CD03.07.24

IFC SET12.20.24

ASSEMBLY

MULTI-OUTLET EMITTER 44REVISED:

STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.

REVISED:

STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.

IRRIGATION TRENCHING

REVISED:

STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.

LATERAL END CAP

TREES

EMITTER LOCATION 45

REVISED:

STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.

DEPTH

REVISED:

STANDARD DETAILISSUED: JULY 1, 2019 DETAIL NO.DETAIL NO.

ROTOR

SPRIKLER HEAD

ADD ALT 8, 9, AND 10

Sheets and Views
Ochoa-1-C-L1.0
Ochoa-1-C-L1.1
Ochoa-2-H-L2.1
Ochoa-2-H-L2.2
Ochoa-3-I-L3.1
Ochoa-3-I-L3.2
Ochoa-4-LD-L4.1
Ochoa-4-LD-L4.2

File details come from the government source that posted it. Updated .