0011869613
ROOFING
PROJECT NUMBER: WG-300-3J & ED-300-3J
PROJECT TITLE: Indefinite Delivery Indefinite Quanity (IDIQ) Roofing The ordering period is one tw elve (12) months base w ith four (4) (12) months option
PROJECT LOCATION: Fort Stew art and Hunter Army Airf ield, Georgia
SET ASIDE: 100% Hubzone
NAICS CODE: 238160
SIZE STANDARD: $19.0 Million
MAGNITUDE OF CONSTRUCTION PROJECT: more than $10,000,000.
SITE VISIT: NO SITE VISIT FOR THIS REQUIREMENT
DUE DATE FOR QUESTIONS: 11 MAY 2023
BONDS: Offer guarantee is required
*Instrution for the preparation of proposal are located in Section L. Faxed or email proposal w ill not be accepted.
X
CHRISTINA A. WEBB 9127675467
NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".
10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE DOCUMENTS
NEGOTIATED
19-Apr-2023
(RFP)
(IFB)
CALL:
IDIQ ROOGING
B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)
See Item 7
2. TYPE OF SOLICITATION
SEALED BID
3. DATE ISSUED
9. FOR INFORMATION A. NAME
SOLICITATION
NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)
Prescribed by GSA
FAR (48 CFR) 53.236-1(e)
11. The Contractor shall begin performance w ithin _______10 calendar days and complete it w ithin ________365 calendar days after receiving aw ard, X notice to proceed. This performance period is X mandatory, negotiable. (See _________________________TASK ORDERS
12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?
(If "YES," indicate within how many calendar days after award in Item 12B.)
X YES NO
13. ADDITIONAL SOLICITATION REQUIREMENTS:
A. Sealed offers in original and __________1 copies to perform the w ork required are due at the place specif ied in Item 8 by ___________ local time ______________18 May 2023 (date). If this is a sealed bid solicitation, offers must be publicly opened at that time.
shall be marked to show the offeror's name and address, the solicitation number, and the date and time of fers are due.
B. An offer guarantee X is, is not required.
C. All offers are subject to the (1) w ork requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.
D. Offers providing less than _______90 calendar days for Government acceptance after the date offers are due w ill not be considered and w ill be rejected.
SOLICITATION, OFFER,
AND AWARD
(Construction, Alteration, or Repair)
1. SOLICITATION NO.
IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.
4. CONTRACT NO.
7. ISSUED BY CODE
MICC - FORT STEWART
976 WILLIAM H. WILSON AVE SUITE 100
FORT STEWART GA 31314
W9124M
PAGE OF PAGES
1 OF
CODE
(Title, identifying no., date):
12B. CALENDAR DAYS
02:00 PM (hour)
Sealed envelopes containing offers
5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.
WG300-3J & ED-300-3J
8. ADDRESS OFFER TO (If Other Than Item 7)
FAX:TEL: (912)767-8420 TEL: FAX:
W9124M23B0007 283
20B. SIGNATURE
(REV. 4-85)STANDARD FORM 1442 BACK
TO SIGN
NSN 7540-01-155-3212
SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)
CODE FACILITY CODE
17. The offeror agrees to perform the w ork required at the prices specif ied below in strict accordance w ith the terms of this solicitation, if this offer is accepted by the Government in w riting w ithin ________ calendar days after the date offers are due.
the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)
AMOUNTS SEE SCHEDULE OF PRICES
18. The offeror agrees to furnish any required performance and payment bonds.
19. ACKNOWLEDGMENT OF AMENDMENTS
(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)
AMENDMENT NO.
DATE
20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN
OFFER (Type or print)
AWARD (To be completed by Government)
21. ITEMS ACCEPTED:
22. AMOUNT 23. ACCOUNTING AND APPROPRIATION DATA
24. SUBMIT INVOICES TO ADDRESS SHOWN IN ITEM
(4 copies unless otherwise specified)
CODE
(Insert any number equal to or greater than
20C. OFFER DATE
25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO
10 U.S.C. 2304(c) 41 U.S.C. 253(c)
CODE27. PAYMENT WILL BE MADE BY:26. ADMINISTERED BY
(Include ZIP Code)14. NAME AND ADDRESS OF OFFEROR 15. TELEPHONE NO. (Include area code)
See Item 14
(Include only if different than Item 14)16. REMITTANCE ADDRESS
30B. SIGNATURE
29. AWARD (Contractor is not required to sign this document.)
document and return _______ copies to issuing office.) Contractor agrees Your of f er on this solicitation, is hereby accepted as to the items listed. This award con-to f urnish and deliv er all items or perf orm all work, requisitions identif ied summates the contract, which consists of (a) the Gov ernment solicitation and on this f orm and any continuation sheets f or the consideration stated in this y our of f er, and (b) this contract award. No f urther contractual document is contract. The rights and obligations of the parties to this contract shall be necessary .
gov erned by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certif ications, and specif ications or incorporated by ref er-ence in or attached to this contract.
30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED 31A. NAME OF CONTRACTING OFFICER (Type or print)
30C. DATE
(Type or print)
TEL: EMAIL:
31B. UNITED STATES OF AMERICA 31C. AWARD DATE
BY
CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE
(Contractor is required to sign this28. NEGOTIATED AGREEMENT
(M ust be fully completed by offeror)OFFER
Section A - Solicitation/Contract Form
SECTION A –Table of Contents
TABLE OF CONTENTS
PART I – THE SCHEDULE
• SECTION A – Solicitation/Contract Form
• SECTION B – Supplies or Services and Prices/Costs
• SECTION C – Descriptions/Specifications/Statement of Work
• SECTION D – Packaging and Marking
• SECTION E – Inspection and Acceptance
• SECTION F – Description and Performance
• SECTION G – Contract Administration Data
• SECTION H – Special Contract Requirements
PART II – CONTRACT CLAUSES
SECTION I – Contract Clauses
PART III – LIST OF DOCUMENTS, EXIBITS AND OTHER ATTACHMENTS
SECTION J – List of Exhibits, Attachments, and Appendices
PART IV – REPRESENTATIONS AND INSTRUCTIONS
SECTION K – Representations, Certifications and Other Statements of Offerors or
Respondents SECTION L – Instructions, Conditions, and Notice to Offerors
SECTION M – Evaluation Factors for Award
Section B - Supplies or Services and Prices
ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
0001 1 Job IDIQ Roofing Base Year and four (4)
FFP
IDIQ Roofing Base Year and four (4) FOB: Destination
PURCHASE REQUEST NUMBER: 0011869613
PSC CD: Z2QA
NET AMT
1001 1 Job OPTION IDIQ Roofing Base Year and four (4)
FFP
IDIQ Roofing Base Year and four (4) FOB: Destination
2001 1 Job OPTION IDIQ Roofing Base Year and four (4)
FFP
IDIQ Roofing Base Year and four (4)
3001 1 Job OPTION IDIQ Roofing Base Year and four (4)
FFP
IDIQ Roofing Base Year and four (4)
4001 1 Job OPTION IDIQ Roofing Base Year and four (4)
FFP
IDIQ Roofing Base Year and four (4)
PROPOSAL PRICE SCHEDULE
Maintain and Repair Roofs (IDIQ), Fort Stewart and Hunter Army Airfield, GA Bid Schedule - Base Year
“Controlled Unclassified Information”
ITEM DESCRIPTION Quantity UNIT U/P Amount
0001 Provide and install roof hatch, 36" x 30" 4 EA
0002 Provide and install gypsum deck plank 2" 305 SF
0003 Demolition of gypsum deck, 2" 305 SF
0004 Provide and install 1 1/2"x18 gauge open-type metal deck galvanized
533 SF
0005 Demolition of 1 1/2"x18 gauge open-type metal deck, galvanized
533 SF
0006 Provide and install 3"x16 gauge open-type metal deck, galvanized
2275 SF
0007 Demolition of 3"x16 gauge open-type metal deck, galvanized 350 SF
0008 Provide and install sheet metal patch, .020 galvanized 260 SF
0009 Demolition of lumber up 2x10 3500 BF
0010 Provide and install lumber, treated up to 2x10 3500 BF
0011 Provide and install cant strips, treated 4 X 4, cut diagonally 2275 LF
0012 Demolition of cant strips 3500 LF
0013 Provide and install CDX plywood sheathing up to 3/4" 7280 SF
0014 Demolition of CDX plywood sheathing up to 3/4" 7280 SF
0015 Provide and install exterior trim, pine, corner board, 1x4 455 LF
0016 Demolition of exterior trim, pine, corner board, 1x4 455 LF
0017 Provide and install exterior trim, pine, corner board, 1x6 455 LF
0018 Demolition of exterior trim, pine, corner board, 1x6 455 LF
0019 Provide and install exterior trim, pine, fascia, 1x6 455 LF
0020 Demolition of exterior trim, pine, fascia, 1x6 455 LF
0021 Provide and install exterior trim, pine, fascia, 1x8 455 LF
0022 Demolition of exterior trim, pine, fascia, 1x8 455 LF
0023 Provide and install fiberglass flexible insulation 3-1/2" kraft faced, R11
455 SF
0024 Demolition of figerglass flexible insulation 3-1/2" kraft faced, R11
455 SF
0025 Provide and install fiberglass flexible insulation 6" kraft faced 455 SF
0026 Demolition of fiberglass flexible insulation 6" kraft faced 455 SF
0027 Provide and install fiberglass flexible insulation 3-1/2" foil side, R11
455 SF
0028 Demolition of fiberglass flexible insulation 3-1/2" foil 1 side, R11
455 SF
0029 Provide and install fiberglass flexible insulation 6" foil side R19
2275 SF
0030 Demolition of fiberglass flexible insulation 6" foil side, R19 2275 SF
0031 Provide and install flexible fiberglass insulation, 9" foil side, R30
455 SF
0032 Demolition of 9" flexible fiberglass insulation, foil side, R30 455 SF
0033 Provide and install fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0034 Demolition of fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0035 Provide and install fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0036 Demolition of fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0037 Provide and install flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0038 Demolition of flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0039 Provide and install vinyl soffit, perforated or solid, and solid vinyl fascia
228 SF
0040 Demolition of soffit, perforated or solid, and fascia 228 SF
0041 Provide and install rigid board insulation, 1" mineral fiberboard, R2.78
305 SF
0042 Demolition of rigid board insulation, up to 2" 15925 SF
0043 Provide and install rigid board insulation, 2" mineral fiberboard, R5.56
15925 SF
0044 Demolition of rigid board insulation, wood fiber, up to 1" 189 SF
0045 Demolition of rigid board insulation wood fiber, up to 2' 21 SF
0046 Provide and install rigid board insulation, 1" Perlite, R2.78 15925 SF
0047 Demolition of rigid board insulation, Perlite, up to 2" 15925 SF
0048 Demolition of rigid board insulation, perlite, up to 1" 9100 SF
0049 Provide and install rigid board insulation, 1" polyisocyanurate, R7.14
4550 SF
0050 Provide and install rigid board insulation, 2" polyisocyanurate, R14.29
15925 SF
0051 Provide and install rigid board insulation, tapered insulation, polyisocyanurate
9100 BF
0052 Demolition of rigid insulation, up to 1" polyisocyanurate 4550 SF
0053 Demolition of rigid insulation, up to 2" polyisocyanurate 9100 SF
0054 Provide and install asphalt shingles, Inorganic, class A, 210- 234 pounds per square includes anti-fungus, 15# felt underlayment and ridge shingles, pneumatic nailed
700 SQ
0055 Add 1 layer #15 felt for low/steep slope 700 SQ
0056 Demolition of asphalt shingles 45500 SF
0057 Provide and install glass roofing felt 455 SQ
0058 Provide and install glass roofing felt, mopped 455 SQ
0059 Provide and install organic roofing felt 455 SQ
0060 Provide and install organic roofing felt, mopped 455 SQ
0061 Install pitch pockets 91 EA
0062 Demolition of 3 ply built up roof with gravel 9100 SF
0063 Demolition of 3 ply built up roof with smooth surface 2125 SF
0064 Demolition of 4 ply built up roof with gravel 14000 SF
0065 Demolition of shingle, felt or roll roofing 119 SQ
0066 Demolition of gravel ballast 469 CY
0067 Demolition of coal tar pitch built-up roof system with gravel/slag surfacing; 4 plies
5 SQ
0068 Demolition of 3 plies glass fiber felt 2 SQ
0069 Provide roof consulting; Infra-red survey to include random moisture survey, extensive core sampling, moisture meter surveys and written report including plan, photos and recommendations
228 SQ
0070 Provide and install EPDM, 15-year warranty, .29 PSF single ply roof system, fully adhered
140 SQ
0071 Demolition of single ply roofing 1750 SF
0072 Provide and install EPDM, 15-year warranty, .40 PSF single ply roof system, fully adhered
140 SQ
0073 Provide and install EPDM, 15-year warranty, .40 PSF single ply roof system, mechanically attached
140 SQ
0074 Provide and install PVC, 15-year warranty, .33 PSF single ply roof system, full adhered
9 SQ
0075 Provide and install PVC, 15-year warranty, .40 PSF single ply roof system, fully adhered
140 SQ
0076 Provide and install PVC, 15-year warranty, .40PSF single ply roof system, mechanically attached
140 SQ
0077 Provide and install #15 organic felt, nailed to deck 119 SF
0078 Provide and install #15 organic felt, spot mopped to deck 1169 SF
0079 Provide and install #15 organic felt, fully mopped to deck 1169 SF
0080 Provide and install modified bitumen roof SBS modified, granule surface cap sheet, poly reinforced, mopped, 15-year warranty
3500 SF
0081 Provide and install modified bitumen roof SBS modified, granule surface cap sheet, poly reinforced, mopped, 15-year warranty
3500 SF
0082 Provide and install modified bitumen roof glass fiber reinforced, mopped, 15-year warranty
3500 SF
0083 Provide and install modified bitumen roof glass fiber reinforced, mopped , 15-year warranty
3500 SF
0084 Provide and install modified bitumen roof smooth surface, cap sheet, mopped, 15-year warranty
3500 SF
0085 Provide and install modified bitumen roof granule surface, cap sheet, torched, 15-year warranty, poly reinforced
3500 SF
0086 Demolition of modified bitumen roofing 3500 SF
0087 Demolition of thermoplastic roofing system 455 SQ
0088 Provide and install thermoplastic polyolefin roofing system, 15-year warranty, mechanically attached
455 SQ
0089 Provide and install concrete pavers 2x2x1 1/2" 2 EA
0090 Remove and replace screws and new neoprene washers 7000 EA
0091 Standing seam metal roof, 1 3/4", 24 gauge structural, fluorocarbon paint system
28000 SF
0092 Framing system, light gage structural, 4 and 12 pitch 28000 SF
0093 Framing system, Sub-purlins, metal, 4" wide, 16 gage 700 LF
0094 Metal roof system, fascia, (Same as roof panels) 7000 SF
0095 Metal roof system, Perforated soffit panel, steel painted 910 SF
0096 Provide and install ridge cap 651 SF
0097 Demolition of ridge cap 651 SF
0098 Demolition of PVC pipe flashing 42 EA
0099 Provide and install PVC pipe flashing, 90 mil thick, up to 4" diameter pipe
42 EA
0100 Demolition of copper flashing 12 SF
0101 Demolition of aluminum flashing 7000 SF
0102 Provide and install aluminum flashing, .032" thick 7000 SF
0103 Provide and install up to 4" diameter plumbing vent flashing 47 EA
0104 Provide and install aluminum drip edge, .016" thick, up to 8" girth, white or mill finish
7000 LF
0105 Provide and install stainless steel flashing, .015" thick 91 SF
0106 Demolition of stainless steel flashing 91 SF
0107 Provide and install stainless steel flashing T-Section waterstop, 22 gauge
53 SF
0108 Provide and install stainless steel scupper outlets 10x10x4" 2 EA
0109 Demolition of scupper outlets 5 EA
0110 Provide and install stainless steel scupper outlets 22x14x4" 1 EA
0111 Provide and install stainless steel scupper outlets 4" to 8"x8'x5" tapered
1 EA
0112 Provide and install stainless steel flashing drip edge, 5" girth 91 LF
0113 Provide and install stainless steel flashing drip edge, 8" girth 9 LF
0114 Provide demolition of steel fascia 91 SF
0115 Demolition of gutters and downspouts 700 LF
0116 Provide and install downspouts .024 aluminum, 3x4", enameled
91 LF
0117 Provide and install downspouts .025 aluminum, 4"x5" enameled
700 LF
0118 Provide and install downspouts 28 gauge 3"x4" corrugated, galvanized steel
91 LF
0119 Provide and install downspouts 28 gauge 4"x5" corrugated, galvanized steel, epoxy painted
700 LF
0120 Provide and install gutter .027 thick 5" box type aluminum gutter
70 LF
0121 Provide and install gutter .032" thick 5" box type aluminum gutter, enamel painted
161 LF
0122 Provide and install gutter .032 custom fabricated with gravel stop aluminum gutter
47 LF
0123 Provide and install gutter 28 gauge 5" galvanized steel painted
47 LF
0124 Provide and install gutter 26 gauge 6" galvanized steel, gutter painted
350 LF
0125 Demolition of cast iron boots 2 EA
0126 Provide and install cast iron roof drainage boots 5 EA
0127 Provide and install metal equipment curb, painted up to 48"x48"
35 EA
0128 Demolition of metal equipment curb, painted up to 48"x48" 35 SF
0129 Provide and install gravel stops .032" thick aluminum, up to 12" face height, mill finish
469 LF
0130 Demolition of gravel stops 469 LF
0131 Provide and install coping cap, .050 aluminum, painted 581 SF
0132 Remove and replace roof drains 15 EA
0133 Remove and reset curb and equipment, no electrical work included
53 EA
0134 Provide rooftop equipment curb, (to 16 SF.) factory fabricated to match roof sheets
14 EA
0135 Remove and install mushroom vents 2 EA
0136 Provide continuous aluminum louver, black finish, 18" to 24" tall with insect screen
140 SF
0137 Gable louver, aluminum, painted, large with insect screen 7 EA
0138 Remove and reinstall ventilator 2 EA
0139 Provide continuous low profile ridge ventilator 7 EA
0140 Remove and reset ridge vent 2 EA
0141 Provide and install aluminum ridge vent, painted 21 LF
0142 Demolition of ridge vent 21 LF
0143 Demolition of soffit vents 21 LF
0144 Provide and install up to 3" aluminum soffit vent, mill or enamel finish
21 LF
0145 Provide and install under eave aluminum vent, mill finish 11 EA
0146 Demolition of eave vents 11 EA
0147 Provide and install expansion joint cover, roof to roof, aluminum
40 LF
0148 Provide and install expansion joint cover, roof to wall, aluminum
40 LF
0149 Provide and install expansion joint, butyl, 1/16", 29" wide, with butyl or neoprene center with foam insulation, metal flanges; for joint openings to 5", aluminum, .032" thick
175 LF
0150 Provide and install expansion joint, butyl, 1/16", 29" wide, with butyl or neoprene center with foam insulation, metal flanges; for joint openings to 5", stainless steel, .018" thick
7 LF
0151 Provide and install suspension system without lath with channels 1 1/2" main @ 48" o.c. w 7/8" @ 16" o.c.
350 SF
0152 Demolition of suspension system without lath, with channels 350 SF
0153 Demolition of drywall 350 SF
0154 Provide for ceiling installation. Add to cost of gypsum wallboard
21 SF
0155 Provide for ceiling over 8' in height. Add to cost of gypsum board
21 SF
0156 Provide and install gypsum wallboard 5/8" drywall, taped and finished
350 SF
0157 Provide and install 2x2x5/8" or 2x4x5/8" fiberglass acoustical ceiling panels
350 SF
0158 Demolition of acoustical ceiling panels 350 SF
0159 Pressure wash metal roof 4431 SF
0160 Apply to existing metal roof flexible acrylic waterproofing system with emulsion saturant, polyester fabric and acylic top coat
7000 SF
0161 Provide and install Paint exterior ferrous metal, one coat zinc primer and two coats aluminum paint. Painting task includes protective work
91 SF
0162 Provide and install Paint wood surface, one coat primer, one coat enamel or alkyd or latex. Painting task includes protective work
231 SF
0163 Provide individual tests for asbestos containing material.
Tests shall be obtained by qualified asbestos abatement removal roofing contractor and performed by a qualified laboratory. Provide test results to Contracting Officer
9 EA
0164 Provide removal of asbestos containing roofing material;
built-up roof membrane. Removal procedures shall comply with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Abatement shall be performed by qualified asbestoss abatement contractor.
21 SQ
0165 Provide removal of asbestos containing roofing material, built-up flashing. Removal procedures shall ocmply with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Abatement shall be performed by qualified asbestos abatement contractor.
117 SF
0166 Provide removal of asbestos containing material; soffit and fascia hardboard. Removal procedure shall comply with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Add to disposal cost of non-asbestos material.
21 SF
0167 Provide individual test (core cut) for composition of roofing materials. Repair test area. Test will determine suitability of infrared scan. Provide report to Contracting Officer
5 EA
0168 Demolish pvc piping, up to 2" 9 LF
0169 Provide and install up to 2" pvc piping, schedule 40, include fittings
9 LF
0170 Extend galvanized plumbing vents, (3' to 7') 2 EA
0171 Extend hot flue stacks to 12" dia. (5' to 7') 1 EA
0172 Remove from roof air handler, refrigerant lines and reinstall 1 EA
0173 Extend duct work, insulated aluminum 18 LF
0174 Remove/reinstall lightning Protection System up to 25 points 18 EA
0175 Remove/reinstall LPS up to 100 points 140 EA
0176 Non-prepriced items 0 LS
0177 Lightning Protection System. Includes a complete structural lightning protection system that meets all requirements for UL Master Label Certification, excluding surge protection. Up to 100 points.
140 EA
SUBTOTAL FS/HAAF, BASE PERIOD (TOTAL OF LINE ITEMS 0001 THROUGH 0177)
Bid Schedule - Option Year 1
0002 Provide and install gypsum deck plank 2" 305 SF
0003 Demolition of gypsum deck, 2" 305 SF
0004 Provide and install 1 1/2"x18 gauge open-type metal deck galvanized
533 SF
0005 Demolition of 1 1/2"x18 gauge open-type metal deck, galvanized
533 SF
0006 Provide and install 3"x16 gauge open-type metal deck, galvanized
2275 SF
0007 Demolition of 3"x16 gauge open-type metal deck, galvanized 350 SF
0008 Provide and install sheet metal patch, .020 galvanized 260 SF
0009 Demolition of lumber up 2x10 3500 BF
0010 Provide and install lumber, treated up to 2x10 3500 BF
0011 Provide and install cant strips, treated 4 X 4, cut diagonally 2275 LF
0012 Demolition of cant strips 3500 LF
0013 Provide and install CDX plywood sheathing up to 3/4" 7280 SF
0014 Demolition of CDX plywood sheathing up to 3/4" 7280 SF
0015 Provide and install exterior trim, pine, corner board, 1x4 455 LF
0016 Demolition of exterior trim, pine, corner board, 1x4 455 LF
0017 Provide and install exterior trim, pine, corner board, 1x6 455 LF
0018 Demolition of exterior trim, pine, corner board, 1x6 455 LF
0019 Provide and install exterior trim, pine, fascia, 1x6 455 LF
0020 Demolition of exterior trim, pine, fascia, 1x6 455 LF
0021 Provide and install exterior trim, pine, fascia, 1x8 455 LF
0022 Demolition of exterior trim, pine, fascia, 1x8 455 LF
0023 Provide and install fiberglass flexible insulation 3-1/2" kraft faced, R11
455 SF
0024 Demolition of figerglass flexible insulation 3-1/2" kraft faced, 0027 Provide and install fiberglass flexible insulation 3-1/2" foil side, R11
455 SF
0028 Demolition of fiberglass flexible insulation 3-1/2" foil 1 side, R11
455 SF
0029 Provide and install fiberglass flexible insulation 6" foil side R19
2275 SF
0030 Demolition of fiberglass flexible insulation 6" foil side, R19 2275 SF
0031 Provide and install flexible fiberglass insulation, 9" foil side, R30
455 SF
0032 Demolition of 9" flexible fiberglass insulation, foil side, R30 455 SF
0033 Provide and install fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0034 Demolition of fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0035 Provide and install fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0036 Demolition of fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0037 Provide and install flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0038 Demolition of flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0039 Provide and install vinyl soffit, perforated or solid, and solid vinyl fascia
228 SF
0040 Demolition of soffit, perforated or solid, and fascia 228 SF
0041 Provide and install rigid board insulation, 1" mineral fiberboard, R2.78
305 SF
0042 Demolition of rigid board insulation, up to 2" 15925 SF
0043 Provide and install rigid board insulation, 2" mineral fiberboard, R5.56
15925 SF
0044 Demolition of rigid board insulation, wood fiber, up to 1" 189 SF
0049 Provide and install rigid board insulation, 1" polyisocyanurate, R7.14
4550 SF
0050 Provide and install rigid board insulation, 2" polyisocyanurate, R14.29
15925 SF
0051 Provide and install rigid board insulation, tapered insulation, polyisocyanurate
9100 BF
0052 Demolition of rigid insulation, up to 1" polyisocyanurate 4550 SF
0053 Demolition of rigid insulation, up to 2" polyisocyanurate 9100 SF
0054 Provide and install asphalt shingles, Inorganic, class A, 210- 234 pounds per square includes anti-fungus, 15# felt underlayment and ridge shingles, pneumatic nailed
700 SQ
0055 Add 1 layer #15 felt for low/steep slope 700 SQ
0056 Demolition of asphalt shingles 45500 SF
0057 Provide and install glass roofing felt 455 SQ
0058 Provide and install glass roofing felt, mopped 455 SQ
0059 Provide and install organic roofing felt 455 SQ
0060 Provide and install organic roofing felt, mopped 455 SQ
0061 Install pitch pockets 91 EA
0062 Demolition of 3 ply built up roof with gravel 9100 SF
0063 Demolition of 3 ply built up roof with smooth surface 2125 SF
0064 Demolition of 4 ply built up roof with gravel 14000 SF
0065 Demolition of shingle, felt or roll roofing 119 SQ
0066 Demolition of gravel ballast 469 CY
0067 Demolition of coal tar pitch built-up roof system with gravel/slag surfacing; 4 plies
5 SQ
0068 Demolition of 3 plies glass fiber felt 2 SQ
0069 Provide roof consulting; Infra-red survey to include random moisture survey, extensive core sampling, moisture meter surveys and written report including plan, photos and recommendations
228 SQ
0070 Provide and install EPDM, 15-year warranty, .29 PSF single ply roof system, fully adhered
0072 Provide and install EPDM, 15-year warranty, .40 PSF single
140 SQ
0073 Provide and install EPDM, 15-year warranty, .40 PSF single ply roof system, mechanically attached
140 SQ
0074 Provide and install PVC, 15-year warranty, .33 PSF single ply roof system, full adhered
9 SQ
0075 Provide and install PVC, 15-year warranty, .40 PSF single ply roof system, fully adhered
140 SQ
0076 Provide and install PVC, 15-year warranty, .40PSF single ply roof system, mechanically attached
140 SQ
0077 Provide and install #15 organic felt, nailed to deck 119 SF
0078 Provide and install #15 organic felt, spot mopped to deck 1169 SF
0079 Provide and install #15 organic felt, fully mopped to deck 1169 SF
0080 Provide and install modified bitumen roof SBS modified, granule surface cap sheet, poly reinforced, mopped, 15-year warranty
3500 SF
0081 Provide and install modified bitumen roof SBS modified, granule surface cap sheet, poly reinforced, mopped, 15-year warranty
3500 SF
0082 Provide and install modified bitumen roof glass fiber reinforced, mopped, 15-year warranty
3500 SF
0083 Provide and install modified bitumen roof glass fiber reinforced, mopped , 15-year warranty
3500 SF
0084 Provide and install modified bitumen roof smooth surface, cap sheet, mopped, 15-year warranty
3500 SF
0085 Provide and install modified bitumen roof granule surface, cap sheet, torched, 15-year warranty, poly reinforced
3500 SF
0086 Demolition of modified bitumen roofing 3500 SF
0087 Demolition of thermoplastic roofing system 455 SQ
0088 Provide and install thermoplastic polyolefin roofing system, 15-year warranty, mechanically attached
455 SQ
0089 Provide and install concrete pavers 2x2x1 1/2" 2 EA
0090 Remove and replace screws and new neoprene washers 7000 EA
0091 Standing seam metal roof, 1 3/4", 24 gauge structural, 0094 Metal roof system, fascia, (Same as roof panels) 7000 SF
0095 Metal roof system, Perforated soffit panel, steel painted 910 SF
0096 Provide and install ridge cap 651 SF
0097 Demolition of ridge cap 651 SF
0098 Demolition of PVC pipe flashing 42 EA
0099 Provide and install PVC pipe flashing, 90 mil thick, up to 4" diameter pipe
42 EA
0100 Demolition of copper flashing 12 SF
0101 Demolition of aluminum flashing 7000 SF
0102 Provide and install aluminum flashing, .032" thick 7000 SF
0103 Provide and install up to 4" diameter plumbing vent flashing 47 EA
0104 Provide and install aluminum drip edge, .016" thick, up to 8" girth, white or mill finish
7000 LF
0105 Provide and install stainless steel flashing, .015" thick 91 SF
0106 Demolition of stainless steel flashing 91 SF
0107 Provide and install stainless steel flashing T-Section waterstop, 22 gauge
53 SF
0108 Provide and install stainless steel scupper outlets 10x10x4" 2 EA
0109 Demolition of scupper outlets 5 EA
0110 Provide and install stainless steel scupper outlets 22x14x4" 1 EA
0111 Provide and install stainless steel scupper outlets 4" to 8"x8'x5" tapered
1 EA
0112 Provide and install stainless steel flashing drip edge, 5" girth 91 LF
0113 Provide and install stainless steel flashing drip edge, 8" girth 9 LF
0114 Provide demolition of steel fascia 91 SF
0115 Demolition of gutters and downspouts 700 LF
0116 Provide and install downspouts .024 aluminum, 3x4", enameled
91 LF
0117 Provide and install downspouts .025 aluminum, 4"x5" enameled
700 LF
0118 Provide and install downspouts 28 gauge 3"x4" corrugated, 700 LF
0120 Provide and install gutter .027 thick 5" box type aluminum gutter
70 LF
0121 Provide and install gutter .032" thick 5" box type aluminum gutter, enamel painted
161 LF
0122 Provide and install gutter .032 custom fabricated with gravel stop aluminum gutter
47 LF
0123 Provide and install gutter 28 gauge 5" galvanized steel painted
47 LF
0124 Provide and install gutter 26 gauge 6" galvanized steel, gutter painted
350 LF
0125 Demolition of cast iron boots 2 EA
0126 Provide and install cast iron roof drainage boots 5 EA
0127 Provide and install metal equipment curb, painted up to 48"x48"
35 EA
0128 Demolition of metal equipment curb, painted up to 48"x48" 35 SF
0129 Provide and install gravel stops .032" thick aluminum, up to 12" face height, mill finish
469 LF
0130 Demolition of gravel stops 469 LF
0131 Provide and install coping cap, .050 aluminum, painted 581 SF
0132 Remove and replace roof drains 15 EA
0133 Remove and reset curb and equipment, no electrical work included
53 EA
0134 Provide rooftop equipment curb, (to 16 SF.) factory fabricated to match roof sheets
14 EA
0135 Remove and install mushroom vents 2 EA
0136 Provide continuous aluminum louver, black finish, 18" to 24" tall with insect screen
140 SF
0137 Gable louver, aluminum, painted, large with insect screen 7 EA
0138 Remove and reinstall ventilator 2 EA
0139 Provide continuous low profile ridge ventilator 7 EA
0140 Remove and reset ridge vent 2 EA
0141 Provide and install aluminum ridge vent, painted 21 LF
0142 Demolition of ridge vent 21 LF
0143 Demolition of soffit vents 21 LF
0144 Provide and install up to 3" aluminum soffit vent, mill or enamel finish aluminum
40 LF
0148 Provide and install expansion joint cover, roof to wall, aluminum
40 LF
0149 Provide and install expansion joint, butyl, 1/16", 29" wide, with butyl or neoprene center with foam insulation, metal flanges; for joint openings to 5", aluminum, .032" thick
175 LF
0150 Provide and install expansion joint, butyl, 1/16", 29" wide, with butyl or neoprene center with foam insulation, metal flanges; for joint openings to 5", stainless steel, .018" thick
7 LF
0151 Provide and install suspension system without lath with channels 1 1/2" main @ 48" o.c. w 7/8" @ 16" o.c.
350 SF
0152 Demolition of suspension system without lath, with channels 350 SF
0153 Demolition of drywall 350 SF
0154 Provide for ceiling installation. Add to cost of gypsum wallboard
21 SF
0155 Provide for ceiling over 8' in height. Add to cost of gypsum board
21 SF
0156 Provide and install gypsum wallboard 5/8" drywall, taped and finished
350 SF
0157 Provide and install 2x2x5/8" or 2x4x5/8" fiberglass acoustical ceiling panels
350 SF
0158 Demolition of acoustical ceiling panels 350 SF
0159 Pressure wash metal roof 4431 SF
0160 Apply to existing metal roof flexible acrylic waterproofing system with emulsion saturant, polyester fabric and acylic top coat
7000 SF
0161 Provide and install Paint exterior ferrous metal, one coat zinc primer and two coats aluminum paint. Painting task includes protective work
91 SF
0162 Provide and install Paint wood surface, one coat primer, one coat enamel or alkyd or latex. Painting task includes protective work
231 SF
0163 Provide individual tests for asbestos containing material.
Tests shall be obtained by qualified asbestos abatement removal roofing contractor and performed by a qualified with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Abatement shall be performed by qualified asbestoss abatement contractor.
21 SQ
0165 Provide removal of asbestos containing roofing material, built-up flashing. Removal procedures shall ocmply with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Abatement shall be performed by qualified asbestos abatement contractor.
117 SF
0166 Provide removal of asbestos containing material; soffit and fascia hardboard. Removal procedure shall comply with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Add to disposal cost of non-asbestos material.
21 SF
0167 Provide individual test (core cut) for composition of roofing materials. Repair test area. Test will determine suitability of infrared scan. Provide report to Contracting Officer
5 EA
0168 Demolish pvc piping, up to 2" 9 LF
0169 Provide and install up to 2" pvc piping, schedule 40, include fittings
9 LF
0170 Extend galvanized plumbing vents, (3' to 7') 2 EA
0171 Extend hot flue stacks to 12" dia. (5' to 7') 1 EA
0172 Remove from roof air handler, refrigerant lines and reinstall 1 EA
0173 Extend duct work, insulated aluminum 18 LF
0174 Remove/reinstall lightning Protection System up to 25 points 18 EA
0175 Remove/reinstall LPS up to 100 points 140 EA
0176 Non-prepriced items 0 LS
0177 Lightning Protection System. Includes a complete structural lightning protection system that meets all requirements for UL Master Label Certification, excluding surge protection. Up to 100 points.
SUBTOTAL FS/HAAF, OPTION 1 PERIOD (TOTAL OF LINE ITEMS 0001 THROUGH 0177)
Bid Schedule - Option Year 2
0002 Provide and install gypsum deck plank 2" 305 SF
0003 Demolition of gypsum deck, 2" 305 SF
0004 Provide and install 1 1/2"x18 gauge open-type metal deck galvanized
533 SF
0005 Demolition of 1 1/2"x18 gauge open-type metal deck, galvanized
533 SF
0006 Provide and install 3"x16 gauge open-type metal deck, galvanized
2275 SF
0007 Demolition of 3"x16 gauge open-type metal deck, galvanized 350 SF
0008 Provide and install sheet metal patch, .020 galvanized 260 SF
0009 Demolition of lumber up 2x10 3500 BF
0010 Provide and install lumber, treated up to 2x10 3500 BF
0011 Provide and install cant strips, treated 4 X 4, cut diagonally 2275 LF
0012 Demolition of cant strips 3500 LF
0013 Provide and install CDX plywood sheathing up to 3/4" 7280 SF
0014 Demolition of CDX plywood sheathing up to 3/4" 7280 SF
0015 Provide and install exterior trim, pine, corner board, 1x4 455 LF
0016 Demolition of exterior trim, pine, corner board, 1x4 455 LF
0017 Provide and install exterior trim, pine, corner board, 1x6 455 LF
0018 Demolition of exterior trim, pine, corner board, 1x6 455 LF
0019 Provide and install exterior trim, pine, fascia, 1x6 455 LF
0020 Demolition of exterior trim, pine, fascia, 1x6 455 LF
0021 Provide and install exterior trim, pine, fascia, 1x8 455 LF
0022 Demolition of exterior trim, pine, fascia, 1x8 455 LF
0023 Provide and install fiberglass flexible insulation 3-1/2" kraft faced, R11
455 SF
0024 Demolition of figerglass flexible insulation 3-1/2" kraft faced, 0027 Provide and install fiberglass flexible insulation 3-1/2" foil side, R11
455 SF
0028 Demolition of fiberglass flexible insulation 3-1/2" foil 1 side, R11
455 SF
0029 Provide and install fiberglass flexible insulation 6" foil side R19
2275 SF
0030 Demolition of fiberglass flexible insulation 6" foil side, R19 2275 SF
0031 Provide and install flexible fiberglass insulation, 9" foil side, R30
455 SF
0032 Demolition of 9" flexible fiberglass insulation, foil side, R30 455 SF
0033 Provide and install fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0034 Demolition of fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0035 Provide and install fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0036 Demolition of fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0037 Provide and install flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0038 Demolition of flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0039 Provide and install vinyl soffit, perforated or solid, and solid vinyl fascia
228 SF
0040 Demolition of soffit, perforated or solid, and fascia 228 SF
0041 Provide and install rigid board insulation, 1" mineral fiberboard, R2.78
305 SF
0042 Demolition of rigid board insulation, up to 2" 15925 SF
0043 Provide and install rigid board insulation, 2" mineral fiberboard, R5.56
15925 SF
0044 Demolition of rigid board insulation, wood fiber, up to 1" 189 SF
0049 Provide and install rigid board insulation, 1" polyisocyanurate, R7.14
4550 SF
0050 Provide and install rigid board insulation, 2" polyisocyanurate, R14.29
15925 SF
0051 Provide and install rigid board insulation, tapered insulation, polyisocyanurate
9100 BF
0052 Demolition of rigid insulation, up to 1" polyisocyanurate 4550 SF
0053 Demolition of rigid insulation, up to 2" polyisocyanurate 9100 SF
0054 Provide and install asphalt shingles, Inorganic, class A, 210- 234 pounds per square includes anti-fungus, 15# felt underlayment and ridge shingles, pneumatic nailed
700 SQ
0055 Add 1 layer #15 felt for low/steep slope 700 SQ
0056 Demolition of asphalt shingles 45500 SF
0057 Provide and install glass roofing felt 455 SQ
0058 Provide and install glass roofing felt, mopped 455 SQ
0059 Provide and install organic roofing felt 455 SQ
0060 Provide and install organic roofing felt, mopped 455 SQ
0061 Install pitch pockets 91 EA
0062 Demolition of 3 ply built up roof with gravel 9100 SF
0063 Demolition of 3 ply built up roof with smooth surface 2125 SF
0064 Demolition of 4 ply built up roof with gravel 14000 SF
0065 Demolition of shingle, felt or roll roofing 119 SQ
0066 Demolition of gravel ballast 469 CY
0067 Demolition of coal tar pitch built-up roof system with gravel/slag surfacing; 4 plies
5 SQ
0068 Demolition of 3 plies glass fiber felt 2 SQ
0069 Provide roof consulting; Infra-red survey to include random moisture survey, extensive core sampling, moisture meter surveys and written report including plan, photos and recommendations
228 SQ
0070 Provide and install EPDM, 20-year warranty, .29 PSF single ply roof system, fully adhered
0072 Provide and install EPDM, 20-year warranty, .40 PSF single
140 SQ
0073 Provide and install EPDM, 20-year warranty, .40 PSF single ply roof system, mechanically attached
140 SQ
0074 Provide and install PVC, 20-year warranty, .33 PSF single ply roof system, full adhered
9 SQ
0075 Provide and install PVC, 20-year warranty, .40 PSF single ply roof system, fully adhered
140 SQ
0076 Provide and install PVC, 20-year warranty, .40PSF single ply roof system, mechanically attached
140 SQ
0077 Provide and install #15 organic felt, nailed to deck 119 SF
0078 Provide and install #15 organic felt, spot mopped to deck 1169 SF
0079 Provide and install #15 organic felt, fully mopped to deck 1169 SF
0080 Provide and install modified bitumen roof SBS modified, granule surface cap sheet, poly reinforced, mopped, 20-year warranty
3500 SF
0081 Provide and install modified bitumen roof SBS modified, granule surface cap sheet, poly reinforced, mopped, 20-year warranty
3500 SF
0082 Provide and install modified bitumen roof glass fiber reinforced, mopped, 20-year warranty
3500 SF
0083 Provide and install modified bitumen roof glass fiber reinforced, mopped , 20-year warranty
3500 SF
0084 Provide and install modified bitumen roof smooth surface, cap sheet, mopped, 20-year warranty
3500 SF
0085 Provide and install modified bitumen roof granule surface, cap sheet, torched, 20-year warranty, poly reinforced
3500 SF
0086 Demolition of modified bitumen roofing 3500 SF
0087 Demolition of thermoplastic roofing system 455 SQ
0088 Provide and install thermoplastic polyolefin roofing system, 20-year warranty, mechanically attached
455 SQ
0089 Provide and install concrete pavers 2x2x1 1/2" 2 EA
0090 Remove and replace screws and new neoprene washers 7000 EA
0091 Standing seam metal roof, 1 3/4", 24 gauge structural, 0094 Metal roof system, fascia, (Same as roof panels) 7000 SF
0095 Metal roof system, Perforated soffit panel, steel painted 910 SF
0096 Provide and install ridge cap 651 SF
0097 Demolition of ridge cap 651 SF
0098 Demolition of PVC pipe flashing 42 EA
0099 Provide and install PVC pipe flashing, 90 mil thick, up to 4" diameter pipe
42 EA
0100 Demolition of copper flashing 12 SF
0101 Demolition of aluminum flashing 7000 SF
0102 Provide and install aluminum flashing, .032" thick 7000 SF
0103 Provide and install up to 4" diameter plumbing vent flashing 47 EA
0104 Provide and install aluminum drip edge, .016" thick, up to 8" girth, white or mill finish
7000 LF
0105 Provide and install stainless steel flashing, .015" thick 91 SF
0106 Demolition of stainless steel flashing 91 SF
0107 Provide and install stainless steel flashing T-Section waterstop, 22 gauge
53 SF
0108 Provide and install stainless steel scupper outlets 10x10x4" 2 EA
0109 Demolition of scupper outlets 5 EA
0110 Provide and install stainless steel scupper outlets 22x14x4" 1 EA
0111 Provide and install stainless steel scupper outlets 4" to 8"x8'x5" tapered
1 EA
0112 Provide and install stainless steel flashing drip edge, 5" girth 91 LF
0113 Provide and install stainless steel flashing drip edge, 8" girth 9 LF
0114 Provide demolition of steel fascia 91 SF
0115 Demolition of gutters and downspouts 700 LF
0116 Provide and install downspouts .024 aluminum, 3x4", enameled
91 LF
0117 Provide and install downspouts .025 aluminum, 4"x5" enameled
700 LF
0118 Provide and install downspouts 28 gauge 3"x4" corrugated, 700 LF
0120 Provide and install gutter .027 thick 5" box type aluminum gutter
70 LF
0121 Provide and install gutter .032" thick 5" box type aluminum gutter, enamel painted
161 LF
0122 Provide and install gutter .032 custom fabricated with gravel stop aluminum gutter
47 LF
0123 Provide and install gutter 28 gauge 5" galvanized steel painted
47 LF
0124 Provide and install gutter 26 gauge 6" galvanized steel, gutter painted
350 LF
0125 Demolition of cast iron boots 2 EA
0126 Provide and install cast iron roof drainage boots 5 EA
0127 Provide and install metal equipment curb, painted up to 48"x48"
35 EA
0128 Demolition of metal equipment curb, painted up to 48"x48" 35 SF
0129 Provide and install gravel stops .032" thick aluminum, up to 12" face height, mill finish
469 LF
0130 Demolition of gravel stops 469 LF
0131 Provide and install coping cap, .050 aluminum, painted 581 SF
0132 Remove and replace roof drains 15 EA
0133 Remove and reset curb and equipment, no electrical work included
53 EA
0134 Provide rooftop equipment curb, (to 16 SF.) factory fabricated to match roof sheets
14 EA
0135 Remove and install mushroom vents 2 EA
0136 Provide continuous aluminum louver, black finish, 18" to 24" tall with insect screen
140 SF
0137 Gable louver, aluminum, painted, large with insect screen 7 EA
0138 Remove and reinstall ventilator 2 EA
0139 Provide continuous low profile ridge ventilator 7 EA
0140 Remove and reset ridge vent 2 EA
0141 Provide and install aluminum ridge vent, painted 21 LF
0142 Demolition of ridge vent 21 LF
0143 Demolition of soffit vents 21 LF
0144 Provide and install up to 3" aluminum soffit vent, mill or enamel finish aluminum
40 LF
0148 Provide and install expansion joint cover, roof to wall, aluminum
40 LF
0149 Provide and install expansion joint, butyl, 1/16", 29" wide, with butyl or neoprene center with foam insulation, metal flanges; for joint openings to 5", aluminum, .032" thick
175 LF
0150 Provide and install expansion joint, butyl, 1/16", 29" wide, with butyl or neoprene center with foam insulation, metal flanges; for joint openings to 5", stainless steel, .018" thick
7 LF
0151 Provide and install suspension system without lath with channels 1 1/2" main @ 48" o.c. w 7/8" @ 16" o.c.
350 SF
0152 Demolition of suspension system without lath, with channels 350 SF
0153 Demolition of drywall 350 SF
0154 Provide for ceiling installation. Add to cost of gypsum wallboard
21 SF
0155 Provide for ceiling over 8' in height. Add to cost of gypsum board
21 SF
0156 Provide and install gypsum wallboard 5/8" drywall, taped and finished
350 SF
0157 Provide and install 2x2x5/8" or 2x4x5/8" fiberglass acoustical ceiling panels
350 SF
0158 Demolition of acoustical ceiling panels 350 SF
0159 Pressure wash metal roof 4431 SF
0160 Apply to existing metal roof flexible acrylic waterproofing system with emulsion saturant, polyester fabric and acylic top coat
7000 SF
0161 Provide and install Paint exterior ferrous metal, one coat zinc primer and two coats aluminum paint. Painting task includes protective work
91 SF
0162 Provide and install Paint wood surface, one coat primer, one coat enamel or alkyd or latex. Painting task includes protective work
231 SF
0163 Provide individual tests for asbestos containing material.
Tests shall be obtained by qualified asbestos abatement removal roofing contractor and performed by a qualified with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Abatement shall be performed by qualified asbestoss abatement contractor.
21 SQ
0165 Provide removal of asbestos containing roofing material, built-up flashing. Removal procedures shall ocmply with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Abatement shall be performed by qualified asbestos abatement contractor.
117 SF
0166 Provide removal of asbestos containing material; soffit and fascia hardboard. Removal procedure shall comply with State of Georgia EPA requirements. Provide disposal manifests to Contracting Officer. Add to disposal cost of non-asbestos material.
21 SF
0167 Provide individual test (core cut) for composition of roofing materials. Repair test area. Test will determine suitability of infrared scan. Provide report to Contracting Officer
5 EA
0168 Demolish pvc piping, up to 2" 9 LF
0169 Provide and install up to 2" pvc piping, schedule 40, include fittings
9 LF
0170 Extend galvanized plumbing vents, (3' to 7') 2 EA
0171 Extend hot flue stacks to 12" dia. (5' to 7') 1 EA
0172 Remove from roof air handler, refrigerant lines and reinstall 1 EA
0173 Extend duct work, insulated aluminum 18 LF
0174 Remove/reinstall lightning Protection System up to 25 points 18 EA
0175 Remove/reinstall LPS up to 100 points 140 EA
0176 Non-prepriced items 0 LS
0177 Lightning Protection System. Includes a complete structural lightning protection system that meets all requirements for UL Master Label Certification, excluding surge protection. Up to 100 points.
SUBTOTAL FS/HAAF, OPTION 2 PERIOD (TOTAL OF LINE ITEMS 0001 THROUGH 0177)
Bid Schedule - Option Year 3
0002 Provide and install gypsum deck plank 2" 305 SF
0003 Demolition of gypsum deck, 2" 305 SF
0004 Provide and install 1 1/2"x18 gauge open-type metal deck galvanized
533 SF
0005 Demolition of 1 1/2"x18 gauge open-type metal deck, galvanized
533 SF
0006 Provide and install 3"x16 gauge open-type metal deck, galvanized
2275 SF
0007 Demolition of 3"x16 gauge open-type metal deck, galvanized 350 SF
0008 Provide and install sheet metal patch, .020 galvanized 260 SF
0009 Demolition of lumber up 2x10 3500 BF
0010 Provide and install lumber, treated up to 2x10 3500 BF
0011 Provide and install cant strips, treated 4 X 4, cut diagonally 2275 LF
0012 Demolition of cant strips 3500 LF
0013 Provide and install CDX plywood sheathing up to 3/4" 7280 SF
0014 Demolition of CDX plywood sheathing up to 3/4" 7280 SF
0015 Provide and install exterior trim, pine, corner board, 1x4 455 LF
0016 Demolition of exterior trim, pine, corner board, 1x4 455 LF
0017 Provide and install exterior trim, pine, corner board, 1x6 455 LF
0018 Demolition of exterior trim, pine, corner board, 1x6 455 LF
0019 Provide and install exterior trim, pine, fascia, 1x6 455 LF
0020 Demolition of exterior trim, pine, fascia, 1x6 455 LF
0021 Provide and install exterior trim, pine, fascia, 1x8 455 LF
0022 Demolition of exterior trim, pine, fascia, 1x8 455 LF
0023 Provide and install fiberglass flexible insulation 3-1/2" kraft faced, R11
455 SF
0024 Demolition of figerglass flexible insulation 3-1/2" kraft faced, 0027 Provide and install fiberglass flexible insulation 3-1/2" foil side, R11
455 SF
0028 Demolition of fiberglass flexible insulation 3-1/2" foil 1 side, R11
455 SF
0029 Provide and install fiberglass flexible insulation 6" foil side R19
2275 SF
0030 Demolition of fiberglass flexible insulation 6" foil side, R19 2275 SF
0031 Provide and install flexible fiberglass insulation, 9" foil side, R30
455 SF
0032 Demolition of 9" flexible fiberglass insulation, foil side, R30 455 SF
0033 Provide and install fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0034 Demolition of fiberglass flexible insulation 3-1/2" unfaced batt, R11
455 SF
0035 Provide and install fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0036 Demolition of fiberglass flexible insulation 6" unfaced batt insulation, R19
2275 SF
0037 Provide and install flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0038 Demolition of flexible fiberglass insulation, 9" unfaced batt, R30
455 SF
0039 Provide and install vinyl soffit, perforated or solid, and solid vinyl fascia
228 SF
0040 Demolition of soffit, perforated or solid, and fascia 228 SF
0041 Provide and install rigid board insulation, 1" mineral fiberboard, R2.78
305 SF
0042 Demolition of rigid board insulation, up to 2" 15925 SF
0043 Provide and install rigid board insulation, 2" mineral fiberboard, R5.56
15925 SF
0044 Demolition of rigid board insulation, wood fiber, up to 1" 189 SF
0049 Provide and install rigid board insulation, 1" polyisocyanurate, R7.14
4550 SF
0050…