I - Drawings 25 FEB 2022.pdf
PDF 3 MB Posted
- Attached to
- Fencing Replacement, Clear Zone Area
- Solicitation number
- FA309922R0004
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GATE B
GATE C
GATE D
GATE E
PROJECT AREA
M X
D P
R E
P A
I R
E E
R
F
E N
C
L E
A
Z
O N
E
A
R E
A
2 12
SITE PLAN
C-002
BID SET XX/XX/XXXX
DRAFTED BY:
A. TREVINO
N
O
R
T
H
AutoCAD SHX Text
SHEET NAME:
AutoCAD SHX Text
SEQUENCE NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LAUGHLIN AIR FORCE BASE, DEL RIO, TEXAS
AutoCAD SHX Text
SHEET ID:
BOTTOM RAIL OF EXISTING GATE LEAF
1"
MIN. 1" CLEARANCE BETWEEN GATE LEAF BOTTOM RAIL
AND NEW CONCRETE SPEED BUMP
8"
8" 5'-4" 8"8"
NEW CONCRETE SPEED BUMP
REBAR#5 AT 6-1/2" ON CENTER
8'-0"
SLOPESLOPE
OUTSIDE
AIRFIELD
AIRFIELD
C
L
VARIES
NEW CONCRETE SPEED
BUMP
REBAR#5 AT 6-1/2" ON
CENTER
EXISTING FENCE AND
GATE
S L O
P E
S L O
P E
AIRFIELD
OUTSIDE
AIRFIELD
M X
R E
P A
E
R
F
E N
E
N
E
A
R E
A
4 12
DETAILS
C-004
BID SET XX/XX/XXXX
DRAFTED BY:
A. TREVINO
NEW CONCRETE SPEED BUMP - SECTION
SCALE:
" = 1'-0"
NEW CONCRETE SPEED BUMP - PLAN
SCALE:
" = 1'-0"
AutoCAD SHX Text
SHEET NAME:
AutoCAD SHX Text
SEQUENCE NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
LAUGHLIN AIR FORCE BASE, DEL RIO, TEXAS
GATE B
A. ADD CONCRETE SPEED BUMP AT VEHICULAR SINGLE GATE (APPROXIMATE WIDTH IS 20'-4"). SEE ATTACHMENT I, DRAWINGS -
DETAILS.
B. ADD CONCRETE SPEED BUMP AT PEDESTRIAN SINGLE GATE (APPROXIMATE WIDTH IS 4'-3"). SEE ATTACHMENT I, DRAWINGS -
DETAILS.
C. REMOVE EXISTING FENCING FABRIC AND REPLACE WITH CHAIN LINK FENCE FABRIC ON EXISTING VEHICULAR GATE, PEDESTRIAN
GATE AND FENCE. FASTEN NEW CHAIN LINK FENCE FABRIC WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION
2.2.1.1 WIRE TIES.
D. REMOVE AND REUSE EXISTING "STOP" SIGNS (2). FASTEN SIGN WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
E. PROVIDE AND INSTALL "WARNING" SIGNS (4). SPECIFICATION TO BE ISSUED IN ADDENDUM ONE.
F. PROVIDE AND INSTALL "STOP GATE CLOSED" (2). FASTEN SIGN WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
G. PROVIDE AND INSTALL NEW GATE LATCH TO SECURE GATE LEAVES TOGETHER.
GATE C
GATE C
A. ADD CONCRETE SPEED BUMP AT VEHICULAR SINGLE GATE (APPROXIMATE WIDTH IS 13'-0"). SEE ATTACHMENT I, DRAWINGS -
DETAILS.
B. REMOVE EXISTING FENCING FABRIC AND REPLACE WITH CHAIN LINK FENCE FABRIC ON EXISTING VEHICULAR GATE AND FENCE.
FASTEN NEW CHAIN LINK FENCE FABRIC WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
C. REMOVE AND REUSE EXISTING "STOP" SIGNS (2). FASTEN SIGN WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
D. PROVIDE AND INSTALL RUBBER SWEEP ALONG LATCH SIDE TO REDUCE THE VERTICAL OPENING FROM 4" TO 1" MAXIMUM
DISTANCE.
E. PROVIDE AND INSTALL "WARNING" SIGNS (4). SPECIFICATION TO BE ISSUED IN ADDENDUM ONE.
GATE D
M X
R E
P A
E
R
F
E N
E
N
E
A
R E
A
6 12
BASE
C-006
BID SET XX/XX/XXXX
DRAFTED BY:
A. TREVINO
AutoCAD SHX Text
SHEET NAME:
AutoCAD SHX Text
SEQUENCE NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
LAUGHLIN AIR FORCE BASE, DEL RIO, TEXAS
GATE D
A. ADD CONCRETE SPEED BUMP AT VEHICULAR SINGLE GATE (APPROXIMATE WIDTH IS 12'-8"). SEE ATTACHMENT I, DRAWINGS -
DETAILS.
B. REMOVE EXISTING FENCING FABRIC AND REPLACE WITH CHAIN LINK FENCE FABRIC ON EXISTING VEHICULAR GATE AND FENCE.
FASTEN NEW CHAIN LINK FENCE FABRIC WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
C. REMOVE AND REUSE EXISTING "STOP" SIGNS (2). FASTEN SIGN WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
D. PROVIDE AND INSTALL "WARNING" SIGNS (4). SPECIFICATION TO BE ISSUED IN ADDENDUM ONE.
GATE E
A. ADD CONCRETE SPEED BUMP AT VEHICULAR SINGLE GATE (APPROXIMATE WIDTH IS 12'-11"). SEE ATTACHMENT I, DRAWINGS -
DETAILS.
B. ADD CONCRETE SPEED BUMP AT PEDESTRIAN SINGLE GATE (APPROXIMATE WIDTH IS 4'-3"). SEE ATTACHMENT I, DRAWINGS -
DETAILS.
C. REMOVE EXISTING FENCING FABRIC AND REPLACE WITH CHAIN LINK FENCE FABRIC ON EXISTING VEHICULAR GATE, PEDESTRIAN
GATE AND FENCE. FASTEN NEW CHAIN LINK FENCE FABRIC WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION
2.2.1.1 WIRE TIES.
D. REMOVE AND REUSE EXISTING "STOP" SIGNS (2). FASTEN SIGN WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
E. PROVIDE AND INSTALL "WARNING" SIGNS (4). REFERENCE SPECIFICATION. SPECIFICATION TO BE ISSUED IN ADDENDUM ONE.
F. PROVIDE AND INSTALL "STOP GATE CLOSED" (2). FASTEN SIGN WITH WIRE TIES AS SPECIFIED IN ATTACHMENT H, UFGS 32 31 13.53, SECTION 2.2.1.1 WIRE TIES.
M X
R E
P A
E
R
F
E N
E
N
E
A
R E
A
7 12
BASE
C-007
BID SET XX/XX/XXXX
DRAFTED BY:
A. TREVINO
AutoCAD SHX Text
SHEET NAME:
AutoCAD SHX Text
SEQUENCE NO.
AutoCAD SHX Text
OF
AutoCAD SHX Text
LAUGHLIN AIR FORCE BASE, DEL RIO, TEXAS
| C-001 |
| C-002 |
| Sheets and Views |
| C-002 |
| C-003 |
| C-004 |
| Sheets and Views |
| C-004 |
| C-005 |
| C-006 |
| Sheets and Views |
| C-006 |
| C-007 |
| Sheets and Views |
| C-007 |
File details come from the government source that posted it. Updated .