This document is an appendix providing existing conditions of an air traffic control tower at Al Asad Air Base in Iraq. It details the current state of various areas and equipment within the tower building including exterior structures, floors, walls, hvac systems, electrical components, plumbing, restrooms, and the control tower. Deficiencies are noted such as damaged ceiling tiles, water leaks, and non-functioning equipment.

The related federal contract opportunity is a solicitation from the Department of the Army Corps of Engineers seeking repairs to the air traffic control tower at Al Asad Air Base. Offerors are invited to submit proposals to address the deficiencies identified in the appendix through repairs and replacement of damaged structures, hvac systems, electrical systems, plumbing fixtures, and other areas within the tower building and surrounding facilities. The opportunity aims to restore the tower and its systems to proper working order to support air traffic control operations at the base.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX

AAAB Air Traffic Control Tower – Existing Conditions

Exterior of Building

Central Air Conditioning Unit

Air Conditioning Unit Ductwork

Main Building (Floor 1)

Steel Door Glass Doors

Split-Pack Unit Drop Ceiling

Covered Windows Temporary Wall

Drop Ceiling Window A/C Unit

Electrical Outlets Wooden Door

Damaged Ceiling Tiles Window A/C Unit

Covered Door Louvers Covered Window + A/C Unit

Floors and Walls Steel Exterior Doors

A/C Unit Corridor Windows

Electrical/Server Room Equipment

Electrical Panels Living Area

Exercise Room Damaged Lighting Fixture

Water Heater Conference Room

Corridor Men’s Restroom Entrance

Water Heater Lavatories

Urinals Washer + Dryer

Restroom Stalls Toilet

Shower Curtain Shower

Restroom Entrance Exposed Ductwork/Piping

Lavatories Toilet

Shower Stall Unit Heater

Damaged Ceiling Tiles

Tower (Floor 3)

Plumbing Piping in Stairway Covered Equipment in Stairway

Covered Ceiling Tile Covered Windows

Water Heater Toilet

Urinal Covered Exhaust Fan

Lavatory Water Pump Switch

Carpet A/C Unit

Covered/Damaged Ceiling Tiles

Covered/Leaking Windows Leaking Pipe Above Ceiling

Water Leaking from Ceiling Carpet Tiles

A/C Unit Covered Windows

Ductwork in Server Room Electrical Panels

Living Area A/C Unit + Covered Window

Tower (Floor 5)

HVAC Equipment on Catwalk

A/C Condensing Unit

Stairway Electrical Outlets

Damaged Drop Ceiling Work Area

A/C Unit Electrical Panel

Damaged Flooring