This is a Performance Work Statement Attachment specifying the analytical methods and technologies required for trace metals analysis across multiple sample matrices. The attachment establishes EPA-approved methodologies for analyzing trace metals in fresh water, salt water, soil, sediment, and tissue samples using Inductively Coupled Plasma Mass Spectrometry (ICP/MS) as the primary method, with ICP/OES as an alternative for freshwater analysis under EPA 200.7. For specialized analyses, the document requires Cold Vapor Atomic Fluorescence (CVAF) for mercury detection across all matrices per EPA 1631/1631E, Hydride Generation-Continuous Thermospray Gas Chromatography-Atomic Absorption Spectroscopy (HG-CT-GC-AAS) for arsenic speciation per EPA 1632, and Ion Chromatography with post-column reaction and UV-Vis spectrophotometry for hexavalent chromium speciation per EPA 1636.

The attachment also addresses sample preparation requirements, including digestion procedures and preconcentration methods, with vendors required to submit Standard Operating Procedures (SOPs) for approval. Media and supplies cleaning protocols must comply with EPA 1669 standards for equipment such as Teflon or silicone tubing, in-line sampling filters, and strainers. This specification supports the Defense Health Agency Contracting Activity's solicitation for trace metals analysis services under solicitation number HT942726RE010, classified as NAICS 541380 (Testing Laboratories) with a $19M size standard, issued under full and open competition.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 3 – Analytical methods

Parameter

Technology

Method Reference

Trace Metals (fresh water)
ICP/MS

ICP/OES (if necessary)

EPA 1638

EPA 200.7

Trace Metals (salt water)
ICP/MS

EPA 1640

Trace Metals (soil/sediment)
ICP/MS

EPA 1638

Trace Metals (tissue)
ICP/MS

EPA 1638

Trace Mercury (all water, soil/ sediment, and tissue)

CVAF
EPA 1631 / 1631E
Arsenic Speciation III (trivalent, 7778-43-0) and V (pentavalent, 7778-43-0)
HG-CT-GC-AAS
EPA 1632
Chromium Speciation VI (Hexavalent, 18540-29-9)
Ion Chromatography (IC) with post-column reaction and UV-Vis spectrophotometry
EPA 1636
Methyl Mercury (water)
Purge & Trap CVAF
EPA 1630
Sample Preparation (digestion for all matrices)
Various
Submit SOP’s for approval
Sample Preparation (preconcentration)
Various
EPA 1640 (or equivalent)
Media/Supplies Cleaning (for example - Teflon or silicone tubing, in-line sampling filters, strainers, etcetera)
Various
EPA 1669

Attachment 3 – ACRONYMS CVAF – Cold Vapor Atomic Fluorescence EPA – U.S. Environmental Protection Agency ICP/MS – Inductively Coupled Plasma Mass Spectrometry ICP/OES – Inductively Coupled Plasma Optical Emission spectroscopy SOP – Standard Operating Procedure