This is an attachment specifying analytical methods for environmental testing and analysis. The document establishes EPA-referenced methodologies and technologies required for measuring trace metals, mercury, and arsenic speciation across multiple sample matrices including fresh water, salt water, soil, sediment, and tissue.

For trace metals analysis, the contractor must employ Inductively Coupled Plasma Mass Spectrometry (ICP/MS) with ICP/OES as a backup for fresh water samples (EPA 1638 and EPA 200.7), ICP/MS for salt water (EPA 1640), and ICP/MS for soil/sediment and tissue samples (EPA 1638). Trace mercury analysis across all matrices requires Cold Vapor Atomic Fluorescence (CVAF) methodology per EPA 1631/1631E. Arsenic speciation for trivalent and pentavalent forms must utilize HG-CT-GC-AAS per EPA 1632, while methyl mercury in water samples requires Purge and Trap CVAF methodology per EPA 1630. Sample preparation procedures for digestion require submission of Standard Operating Procedures (SOPs) for approval, preconcentration must follow EPA 1640 or equivalent standards, and media/supplies cleaning procedures must comply with EPA 1669. All methodologies referenced are established by the U.S. Environmental Protection Agency.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 3 – Analytical methods

Parameter

Technology

Method Reference

Trace Metals (fresh water) ICP/MS ICP/OES (if necessary)

EPA 1638

EPA 200.7

Trace Metals (salt water) ICP/MS

EPA 1640

Trace Metals (soil/sediment) ICP/MS

EPA 1638

Trace Metals (tissue) ICP/MS

EPA 1638

Trace Mercury (all water, soil/ sediment, and tissue)

CVAF EPA 1631 / 1631E

Arsenic Speciation III (trivalent, 7778-43-0) and V (pentavalent, 7778-43-0)

HG-CT-GC-AAS EPA 1632

Methyl Mercury (water) Purge & Trap CVAF EPA 1630

Sample Preparation (digestion for all matrices)

Various Submit SOP’s for approval

Sample Preparation (preconcentration)

Various EPA 1640 (or equivalent)

Media/Supplies Cleaning (for example - Teflon or silicone tubing, in-line sampling filters, strainers, etcetera)

Various EPA 1669

Attachment 3 – ACRONYMS

CVAF – Cold Vapor Atomic Fluorescence EPA – U.S. Environmental Protection Agency ICP/MS – Inductively Coupled Plasma Mass Spectrometry ICP/OES – Inductively Coupled Plasma Optical Emission spectroscopy SOP – Standard Operating Procedure