A02. PWS Attach 2 - EDD Specifications.pdf
PDF 173 KB Posted
- Attached to
- Trace Metal Sample Analysis
- Solicitation number
- HT942726RE010
- Issued by
- Not on record
About this file
This is an Electronic Data Deliverable (EDD) Specifications document that establishes requirements for submitting analytical laboratory data in tab-delimited text file format to Defense Centers for Public Health – Aberdeen (DCPH-A).
The contractor must deliver EDD files that contain quantitated results in appropriate units or reporting limits for requested chemical parameters, with all data identified by DCPH-A lab numbers. The EDD and hardcopy reports must contain identical information and data, and the process generating both must be validated to demonstrate equivalency. Files must be named according to a specified convention: "P[Pickup Order #].txt" or "[Shipment #].txt" (e.g., P112.txt for Pickup Order 112). The tab-delimited file comprises 15 required fields including Lab_Code, Pickup_Delivery_Order, Sample_Number, TestCode, Analyte_Code, Final_Result, Text_Result, Additional_Qualifiers, Units, Dilution_Factor, Date_Time_Analyzed, MDL, Lab_Reporting_Limit, and LOD. All fields must be separated by tab characters (ASCII 9), and each line must be terminated with a carriage return (ASCII 13) and line feed (ASCII 10), with an empty line required in the last row. Completed EDD files should be emailed to dha.apg.pub-health-a.mbx.dls-contract-data@health.mil, with questions directed to the Contracting Officer's Representative (COR).
View the file
Other files
| File | Type | Posted |
|---|---|---|
| A02 PWS FINAL v2 COR.docx | DOCX document | |
| Attachment 6-Pricing Sheet v2.xlsx | XLSX spreadsheet | |
| Solicitation - HT942726RE010-0001.docx | DOCX document | |
| A02. PWS Attach 1 - Final Analytical Report & EDD Requirements v2.docx | DOCX document | |
| A02. PWS Attach 4 - Limit of Quantitation (LOQ) v2.docx | DOCX document | |
| A02. PWS Attach 3 - Analytical Methods v2.docx | DOCX document | |
| A02. PWS Attach 3 - Analytical Methods.pdf | ||
| A02. PWS Attach 4 - Limit of Quantitation (LOQ).pdf | ||
| A02. PWS Attach 1 - Final Analytical Report & EDD Requirements.pdf | ||
| Attachment 6-Pricing Sheet.xlsx | XLSX spreadsheet | |
| Solicitation - HT942726RE010_final.docx | DOCX document |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AUG 22
Attachment 2 - Electronic Data Deliverable (EDD) Specifications
Tab Delimited Text File Format
Electronic Data Deliverable (EDD)
The electronic copy of the Data Package is commonly referred to as the contract Electronic Data Deliverable or EDD.
The electronic data deliverable (EDD) and hardcopy reports are required to use and have the same information (sample numbers, field numbers, etc.) and data (analytical results, units). The process that generates the hard copy and EDD is required to be validated to demonstrate that the process provides identical information and data.
The EDD will contain quantitated results in appropriate units, or reporting limits, for the requested chemical parameters.
Sample data shall be identified by Defense Centers for Public Health – Aberdeen (DCPH-A) lab numbers. Please note that the contractor shall transfer the data electronically from their lab to the DCPH-A lab using the file format described below:
EDD Naming Convention
The database containing the EDD should be named using the following format:
Pickup Order #.txt or Shipment #.txt
Example 1. The EDD for Pickup Order 112 would be as follows:
P112.txt
Example 2. The EDD for Shipment 8199 would be as follows:
8199.txt
Contents of the tab delimited EDD file
The following table lists the fields in the tab delimited file along with the data type, the maximum size in characters and a description. Note: The EDD file shall contain an empty line in the last row of the EDD.
Tab Delimited EDD Line Specifications:
Field Name Type Size Description Lab_Code Text 4 DCPH-A queue code for the contract lab which performed the analysis.
DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Pickup_Delivery_Order Text 6 Pickup Order to which this sample belongs, Please enter the Outsource #.
DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Sample_Number Text 13 The DCPH-A sample number (assigned by DCPH-A) DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
TestCode Text 10 The DCPH-A LIMS Test Code DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Analyte_Code Text 15 The LIMS standard Analyte_Code, typically the CAS# DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Final_Result Number (Decimal) The numberic result (round to the proper sig figs and decimal places) DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Text_Result Text 250 Text result. Not applicable to the results of most contracted Analyte Codes.
DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Additional_Qualifiers Text 8 Additional qualifiers, for example any EPA Qualifiers.
DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Units Text 10 Units of the results
AUG 22
DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null Dilution_Factor Number (Decimal) Dilution factor applied to the observed result (already applied) DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Date_Time_Analyzed Date mm/dd/yy Date the analysis was performed.
DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
MDL Number (Decimal) Method Detection Limit DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null
Lab_Reporting_Limit Number (Decimal) Lab Reporting Limit/Practical Quantitation Limit/Limit of Quantitation DELIMITER Tab character (ASCII 9) is used as field separator, even if proceeding field is null LOD Number (Decimal) Limit of Detection LINE TERMINATORS Each line is terminated by a carriage return (ASCII 13) and a line feed (ASCII 10)
File Delivery
The EDD file should be emailed to the following address: dha.apg.pub-health-a.mbx.dls-contract-data@health.mil
Questions or comments regarding this guidance should be addressed to the COR.
mailto:dha.apg.pub-health-a.mbx.dls-contract-data@health.mil
| Tab Delimited Text File Format |
| Electronic Data Deliverable (EDD) |
| EDD Naming Convention |
| Contents of the tab delimited EDD file |
| Tab Delimited EDD Line Specifications: |
| File Delivery |
File details come from the government source that posted it. Updated .