O&M Equipment List for TSIF - Attachment 2.pdf

PDF 122 KB Posted

Attached to
Operations and Maintenance Services
Solicitation number
HSTS01-09-R-RES270
Issued by

About this file

TSIF Equipment List (Attachment 2 to Amendment 7)

View the file

Other files

File Type Posted
AMENDMENT 10.doc DOC document
O&M Solicitation HSTS01-09-R-RES270 Questions.doc DOC document
HSTS01-09-R-RES270 Amendment 9.docx DOCX document
O&M As-Build - Attachment 1.pdf PDF
Amendment 7.doc DOC document
Page 63 of 68.doc DOC document
Page 62 of 68.doc DOC document
HSTS01-09-R-RES270 Amendment 2 Pg 62.doc DOC document
HSTS01-09-R-RES270 FC Equipment List.pdf PDF
HSTS01-09-R-RES270 Amendment 1.doc DOC document
NDA-DHS Form 11000 3 Pages.pdf PDF
HSTS01-09-R-RES270 FC Equipment List.pdf PDF
TSA_MD_2410_1_ FINAL_090313.pdf PDF
HSTS01-09-R-RES270 Solicitation Pkg 032409.pdf PDF
HSTS01-09-R-RES270 Wage Determination.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TSIF New Mechanical Equipment

TERMINAL BOX SCHEDULE

NUMBER

OF UNITS

Unit Symbol/Size

Type

CFM Model #

TRANE MAX DESIGN MIN

1 VAV-1 SINGLE 200 125 50 TITUS DESV

1 VAV-2 SINGLE 250 170 68 TITUS DESV

3 VAV-3 SINGLE 450 380 152 TITUS DESV

3 VAV-4 SINGLE 800 650 260 TITUS DESV

4 VAV-5 SINGLE 1350 1000 400 TITUS DESV

5 VAV-6 SINGLE 2000 1750 700 TITUS DESV

New Fan Coil Unit List

FCU # Serial # Model # Filter Size Location FCU 2 T08G48789 BCHC090 16x20x2 (6) Lobby FCU 3 T08G48790 BCHC024 12x24x2 (2) 1st FLR FCU 4 T08G48791 BCHC024 12x24x2 (2) 1ST FLR FCU 5 T08G48792 BCHC036 16x24x2 (2) mezzanine FCU 6 T08G48793 BCHC024 12x24x2 (2) 2nd FCU 7 T08G48794 BCHC024 12x24x2 (2) 2nd Flr FCU 8 T08G48795 BCHC012 12x24x2 (2) 2nd Flr FCU 9 T08G48796 BCHC012 12x24x2 (2) 2nd Flr

FCU 10 T08G48797 BCHC036 16x20x2 (2) 2nd Flr FCU 11 T08G48798 BCHC054 16x20x2 (4) 2nd Flr FCU 12 T08G48799 BCHC024 12x24x2 (2) mezzanine

NEW PUMPS

UNIT

NUMBER

SERVICE LOCATION CASING

TYPE

GPM HD

FT

PSIG PUMP

RPM |BHP

MOTOR MODEL

CWP-3 Chilled glycol

Mechanical room inline 280 55 125 1800 6.5 480 3 60 B&G80

HWP 1 Hot water Boiler room inline 200 69 175 1750 480 3 60 3095cv50p5

HWP 4 Hot water Boiler room inline 150 82 175 1750 480 3 60 3095cv- 30p54

HWP 5 Hot water Boiler room inline 50 75 175 1750 480 3 60 2095cv- 30p54

HOT WATER HEATER

number service location capicty volts Total watts

Model number Serial number

New hot water heater

2nd Janitors closet floor 119 gal. 480 1000 Sandblaster

CSB120121FEB

0834M002998

NEW AIR HANDLING

number service location TOTAL

AIRFLOW

MIN.OA

CFM

RPM MOTOR

HP

MANUFACTURE

AHU-7 PAX

SCREENING

2ND 9000

FLOOR

900 1600 7.5 Trane MCCB017

NEW CHILLER

Air Cooled Chiller service location Min.

capacity

Chiller water Refrigerant refrigerant Compressor Manufact.

Model number

Flow rate glycol ewt lwt type No. of circuits qty Tons each type

Ch-3 Chill water

Chiller enclosure tons

280 40 54 44 22 2 2 60 Helical rotary

3multi stack(ms80)

FAN SCHEDULE

CFM SERVICE Location Fan type

Fan Rpm

Motor hp

Motor volts

Motor phs

Motor cyc

Model Number

EFA 200 TOILET

ROOMS

205,206

RESTROOM INLINE 900 48W 120 1 60 GREENHECK

CSP-A-200

Control Checks unit number Service location Model

/manufacture size

Control check 1 Glycol cp 1 Mechanical room Mueller steam valve/ 721

Control check 2 Glycol cp 2 Mechanical room Mueller steam valve/ 721

Control check 3 Glycol cp 3 Mechanical room Mueller steam valve/ 721

Control check 4 CWP 4 Mechanical room Mueller steam valve/ 721

Control check 5 CWP 5 Mechanical room Mueller steam valve/ 721

Control check 6 CWP 6 Mechanical room Mueller steam valve/ 721

Control check 7 Hwp 2 Boiler room Mueller steam valve/ 721

Control check 8 Hwp 4 Boiler room Mueller steam valve/ 721

Control check 9 Hwp 5 Boiler room Mueller steam valve/ 721

A/C UNITS LOCATION/SERVICE VOLTS PHASE AMPS MODEL

MISTUBUSHI A/C

UNIT(EVAPORATOR)

FACP ROOM 208/230 1 MYS-

A1SNA

COMPRESSOR SYSTEMS MODEL HP Vlts phase manufacture Compressor Dry pipe system LT620100A 1 115 1 General air products Compressor (2) HVAC system 3SF4AD 3/4 115 1 CUTRIS

TOLEDO

INLINE

CHEMICAL

FEEDERS

LOCATION

Model Gallons Working Pressure

Working Temp

Manufacture

HOT WATER

AND CHILL

WATER LOOP

DBF-5H 5 300 PSI 200 F Neptune

CONDENSATE DRAIN PUMPS SERIAL NO# RPM HP

BHS TESTING AREA (8) Little Gaint VCL-

45ULS

----------------- 1/5

FCU (11) and Fire Control Room A/C (1)

Little Gaint VCL-

45ULS

-------------------- 1/5

TSIF EXISTENT EQUIPMENT

AIR COOLED CHILLERS

IDENTIFICATION COOLING

TONS

UNIT ELECTRICAL

DATA

DESIGN

UNIT AREA

SERVED

LOCATION VOLTS PHASE FLA MANNUFACTURE MODEL

C-1 Building CHILLER

COURT

109 480 3 273 Trane RTAA

C-2 Building CHILLER

COURT

109 480 3 273 Trane RTAA

C-3 Building CHILLER

COURT

109 480 3 273 Trane RTAA

HYDRONIC PUMP----HOT WATER SYSTEM

IDENTIFCATION TYPE PERFORMANCE MOTOR DATA BASIS OF

DESIGN

UNIT Location SYSTEM

SERVED

Style Dri ve Gp m

HDFT RPM H

P

VOLTS PHASE Manufacture and model #

HWP-2 Boiler Rm BOILER 2 inlin e close 200 69’ 1750 5 480 3 Weinman CO. series

CV.

3095CV

HWP-3 Boiler Rm CONCOURSE

UNIT

HEATERS

inlin e close 140 82’ 1750 5 480 3 Weinman CO. series

CV.

2595CV

HWP 6 Boiler Rm AHU 1,2,4 FCU

1- 10, 2ND

inlin e FLR

EAST SIDE

VAV BOX

close 50 75’ 1750 3 480 3 Weinman CO. series

CV.

2095CV

HWP-7 MER 240 inlin e close 33 39’ 1750 3/

208 3 Weinman CO. series

CV.

1057CV

HWP-

1,4, 5

THESE PUMPS HAVE BEEN REPLACED PLEASE SEE PUMPS UNDER NEW EQUIPMENT

HYDRONIC PUMP---CHILL WATER PUMPS

IDENTIFCATION TYPE PERFORMANCE MOTOR DATA BASIS OF

DESIGN

UNIT LOCATION SYSTEM

SERVED

STYLE DRIVE GPM HDFT RPM HP VOLT

S

PHA

SE

Manfacture and Model

CWP-

MER 240 CHILLER-

INLINE CLOSE 264 65’ 1750 7.5 480 3 Weinman CO.

series CV.

3095CV

CWP-

MER 240 CHILLER-

INLINE CLOSE 264 65’ 1750 7.5 480 3 Weinman CO.

series CV.

3095CV

CWP-

THIS PUMP HAS BEEN REPLACED PLEASE SEE PUMPS UNDER NEW EQUIPMENT

CWP-

MER 240 VAV 1

AND

AHU-3

INLINE CLOSE 155 60’ 1750 5 480 3 Weinman CO. series

CV.

3095CV

CWP-

MER 240 AHU1,2,4,

VAV 2

INLINE CLOSE 170 77’ 1750 5 480 3 Weinman CO. series

CV.

3095CV

CWP-

MER 240 AHU 1,2,4

VAV 2

INLINE CLOSE 170 77’ 1750 5 480 3 Weinman CO. series

CV.

3095CV

CAST IRON BOILERS

IDENTIFICATION FUEL

TYPE

AGA

INPUT

AGA

OUTPUT

I=B=R FLUE

SIZE

Base of Design Unit Location EDR STEAM WATER

B-1 Boiler Room

Nat.

Gas

2940 2352 7608 1826 2045 21” PEERLESS

211A-15

B-2 Boiler Room

Nat.

Gas

2940 2352 7608 1826 2045 21” PEERLESS

211A-15

UNIT HEATERS

IDENTIFICATION HTG

MBH

Water Data Air Data Electrical Data Basis of

Desing UNIT LOCATION GPM PD ENT DROP CFM ENT FAT volts phase hp Manufacture

UH-1

thru

Concourse 245 24.5 3.5 200 20 5500 60 101 480 3 3/4 LJ Wing Model

26LC

AIR HANDLING UNITS

IDENTIFICATION TOTAL

AIR

FLOW

CFM

MIN

OA

CFM

Electrical Data Basis of Desing UNIT LOCATION SERVICES volts phase hp Manufacture

AHU-1 Mezzanine BHS TESTING

AREA

9000 2000 480 3 15 TRANE

MCCA017

AHU-2 Mezzanine BHS TESTING

AREA

9000 750 480 3 15 TRANE

MCCA017

AHU-3 North Mech.

room

2ND 11500 FLR

OFFICES

700 480 3 15 TRANE

MCCA021

AHU-4 South Mech.

room

2ND 10000 FLR

OFFICES

1400 480 3 15 TRANE

MCCA021

AHU-5 North Mech.

room

2ND 10000 FLR

OFFICES

3667 480 3 15 TRANE

MCCA021

AHU 6 South Mech.

room

2ND 4500 FLR

OFFICES

1342 480 3 15 TRANE

MCCA010

FAN COIL UNIT

UNIT SERVICE AIR

DATA

CFM

MOTOR DATA MANUFACTURE

FCU-1 BHS

ROOM

3600 3

HP

SPEED

480/3/60

EXHAUST FAN SCHEDULE

CFM SERVICE Location Fan type Fan Rpm

Motor hp

Motor volts

Motor phs

Model Number

EF

9769 VAV 1 ROOF PRV-

BI/BELT

795 5 480 3 GREENHECK

G8-300-50

EF-

11338 AHU-3 ROOF PRV-

BI/BELTS

890 7.5 480 3 GREENHECK

G8-300-50

EF-

1000 COMPRESSOR

RM 241

ROOF PRV-

BI/BELTS

1180 1/2 120 1 GREENHECK

GB-120-4

EF-

9833 AHU-4 ROOF PRV-

BI/BELTS

795 5 480 3 GREENHECK

G8-300-50

EF-

4071 VAV 2 ROOF PRV-

BI/BELTS

790 1.5 480 3 GREENHECK

G8-240-15

CONCOURSE EXHAUST FAN SCHEDULE

Unit

CFM SERVICE Location Fan type Fan Rpm

Motor hp

Motor volts

Model Number

EF

21122 CONCOURSE

EAST

CONCOURSE PROP/BELT 750 5 480 3 GREENHECK

SPNE-42

EF-

21122 CONCOURSE

EAST

CONCOURSE PROP/BELT 750 7.5 480 3 GREENHECK

SPNE-42

EF-

21122 CONCOURSE

WEST

CONCOURSE PROP/BELT 750 1/2 120 1 GREENHECK

SPNE-42

EF-

21122 CONCOURSE

WEST

CONCOURSE PROP/BELT 750 5 480 3 GREENHECK

SPNE-42

EXHAUST FAN SCHEDULE

CF

M

SERVICE Location Fan type Fan Rpm

Motor hp

Motor volts

Model Number

EF 5 500 BHS ELECTRICAL

ROOM

CONCOURSE BI/BELT 1960 1/2 120 1 GREENHECK

BSQ-80-3

EF-6 500 BHS ELECTRICAL

ROOM

CONCOURSE BI/BELTS 1960 1/2 120 1 GREENHECK

BSQ-80-3

EF-7 750 TOILETS/ELEVATOR

MACHINE ROOMS

CONCOURSE BI/BELTS 1985 1/2 120 1 GREENHECK

BSQ-90-5

EF-8 200 CUSTODIAL SMALL BI/BELTS 1595 1/2 120 1 GREENHECK

HOT WATER HEATER

number service location capicty volts Total watts

Model number

Serial number water heater 2

2nd MECH.ROOM floor 30 gal. 480 3000 RHEEM

81V30DC

R-0446B00641

WATER

HEATER

2ND MECH ROOM

FLOOR 10 120 2000 RHEEM

81VP10S

RH0599313532

WATER

HEATER

1ST MEZZANINE FLOOR

BATHROOM

40 480 9000 RUDD

ELD40-3

DR0300CU0899RR04

WATER

HEATER

1ST JANITORS

CLOSET

FLOOR

JANITORS

CLOSET

30 480 4500 RUDD

ELDS30-B

RR0404D04662

A/C

UNITS

LOCATION/SERVICE CFM VOLTS PHASE HZ TON

S

HP MODEL

CRAC-1 LAN/TELEPHONE

2ND

FLOOR

480 3 60 6 1.5 LIEBERT

UNIT

VH072G

CLOSET OFFICE BSQ-70-4

EF-9 750 TOILETS/

ELEVATOR

MACHINE ROOM

SMALL

WALL

OFFICE

BI/BELTS 2100 1/2 120 1 GREENHECK

BSQ-80-5

EF-16 HAS BEEN CAPPED OFF

EF-15 500 SECOND FLOOR

OFFICES

ROOF PRV-

BI/BELTS

1610 1/2 120 1 GREENHECK

GB-90-4

EF-17 1580 SECOND FLOOR

OFFICES

ROOF PRV-

BI/BELTS

1685 1/2 120 1 GREENHECK

GB-130-5

EF-18 HAS BEEN CAPPED OFF