Bldg_64_Asbestos_Rept_Acrobat_Pro.pdf

PDF 517 KB Posted

Attached to
Renovate Building 64, FLETC, Glynco, GA
Solicitation number
HSFLGL13B00004
Issued by

About this file

Lead Asbestos Report (Section J Attachment 2)

View the file

Other files

File Type Posted
HSFLGL-13-B-00004_000003.pdf PDF
HSFLGL-13-B-00004_000002.pdf PDF
HSFLGL-13-B-00004_SF-30_Amendment_000001.pdf PDF
FMD-42_DailyReport.pdf PDF
DavisBaconWageRate.pdf PDF
DHS_Form_700-3.pdf PDF
FMD_-66SafetyVio.pdf PDF
OF_306.pdf PDF
BadgeApp_SEM17.pdf PDF
QuestionPublicTrust_SF85P.pdf PDF
DHS_Form_11000-6.pdf PDF
ConstructInvoice.pdf PDF
347_Instruction.pdf PDF
Invoice_Cover.pdf PDF
FormI-9.pdf PDF
WH_347.pdf PDF
DOLDavisBaconPoster.pdf PDF
HSFLGL-13-B-00004.pdf PDF
AffidavitIndividualSuretySF28-03.pdf PDF
SF_1444.pdf PDF
PerformanceBond_SF_25-96.pdf PDF
Equal_Employment.pdf PDF
Bid_Bond_SF_24-98.pdf PDF
FMD-65Compliance.pdf PDF
StandardForm1413.pdf PDF
PaymentBond_SF_25A-98.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Basis of Design...:.. Final Design Submittal

Renovations to Building 64

FLETC- Glynco, Georgia

Renovations to Building 64

Executive Summary

This project involves renovations and upgrades of the existing three story administrative

Building 64. The building is located at the Federal Law Enforcement Training Center in

Brunswick, GA and was built in 1968 to serve as an enlisted men's dormitory for Naval Air

Station, Glynco..

The facility is a 22,000 SF, three story concrete framed/floored structure used for office space in support of training programs at the FLETC. The facility underwent renovations in 1982. This renovation converted the facility from dormitory space to office space. The current exterior enclosure contains concrete masonry units and structural clay tile units from its original construction. The renovation added additional concrete masonry units along with metal studding and interior gypsum board finishes with a stucco "tabby'' exterior finish. Insulation was also added to the facility at this time. The resulting exterior wall thickness is approximately 14". The stucco finish is in poor condition and several panels have pulled lose from the substructure. The existing roofing system contains an estimated 1 W' of insulation under an asphalt roof. During site investigations it was discovered that existing steps and handicap ramps do not meet codes.

Mechanical and electrical systems were also found to have deficiencies. Structurally the facility is in good condition.

The facility is being designed to achieve LEED Silver certification. See LEED project checklist in

Appendix "A".

The project will be bid with no alternates.

Asbestos and Lead Remediation

Testing was performed to determine the extent of asbestos and lead contamination. The complete Asbestos and Lead Survey Reports are attached. No lead containing materials were found. Asbestos contamination is limited to floor tile and floor tile associated materials. Overall the facility had low levels of contaminated materials. See Appendix B for full report.

LEAD AND ASBESTOS REPORT

RENOVATION TO BUILDING 64

FEDERAL LAW ENFORCEMENT TRAINING CENTER

GLYNCO, GEORGIA

REPORT DATE: MAY 4, 2012

INSPECTION DATE: FEBRUARY 23, 2012

Asbestos Inspection

Asbestos inspection for suspect asbestos-containing building materials (ACM) was conducted at Glynco, Georgia, on February 23, 2012. The investigation and survey for asbestos was limited to the building construction that is expected to be impacted by the "Renovation" construction project. Fifty-two

(52) asbestos samples were collected. Ten (10) were found to contain asbestos. The sample descriptions, locations and laboratory analysis findings are provided within this report.

SAMPLE# COLOR OF PAINT

A-022312-01 PIPE JOINT

A-022312-02 PIPE JOINT

A-022312-03 PI PE JOINT

A-022312-04 PIPE JONI T

A-022312-05 2x4 CEILING TILE

A-022312-06 6" BLACK RUBBER BASE

A-022312-07 CARPET

A-022312-08 GYPSUM & JOINT COMPOUND

A-022312-09 4" BROWN RUBBER BASE

A-022312-10 1'x1' BROWN VCT

A-022312-11 2x4 CEILING TILE

A-022312-12 GYPSUM BOARD & JOINT COMPOUND

A-022312-13 GYPSUM BOARD & JOINT COMPOUND

A-022312-14 GYPSUM BOARD & JOINT COMPOUND @

PLENUM

A-022312-15 2x4 CEILING TI LE

A-022312-16 4" BLACK RUBBER BASE

A-022312-17 MAROON CARPET

A-022312-18 GYPSUM & JOINT COMPOUND

A-022312-19 1'x1' VCT

A-022312-20 4" BROWN RUBBER BASE

A-022312-21 2x4 CEILING TILE

A-022312-22 GYPSUM BOARD

A-022312-23 4" BROWN RUBBER BASE

A-022312-24 1'x1' VCT

A-022312-25

PURPLE CARPET

Asbestos:

A-022312-26 GYPSUM BOARD W/WALL PAPER

A-022312-27 GYPSUM BOARD & JOINT COMPOUND

A-022312-28 BLUE CARPET

A-022312-29 4" BLACK RUBBER BASE

A-022312-30 GYPSUM BOARD

A-022312-31 LIGHT BROWN VCT

A-022312-32 MAROON CARPET

A-022312-33 LIGHT BROWN VCT

A-022312-34 4" BROWN RUBBER BASE

A-022312-35 GYPSUM BOARD

A-022312-36 CEILING TILE

A-022312-37 GYPSUM BOARD

A-022312-38 LIGHT TAN VCT

A-022312-39 GYPSUM BOARD

A-022312-40 LIGHT TAN VCT

A-022312-41 WHITEVCT

A-022312-42 WHITE CONCRETE BLOCK

A-022312-43 SHELL FACADE

A-022312-44 BROWN STAIR RUNNER

A-022312-45 BLACK STAIR TREAD

A-022312-46 TANVCT

A-022312-47 BROWN STAIR RUNNER

A-022312-48 BLACK STAIR TREAD

A-022312-49 TANVCT

A-022312-50 BROWN STAIR RUNNER

A-022312-51 BLACK STAIR TREAD

TAN VCT

A-022312-52

Environmental Hazards Services, L.L.C

Report Number: Client Number: 25-3802 12-03-00863

Project/Test Address: 1042-A

Client Sample

Number

Layer Type Lab Gross Description Asbestos Other

Materials Lab Sample

Number

12-03-00863-019A A-022312-19 Tile Tan Vinyl 5% Chrysotile 95% Non-Fibrous

Total Asbestos: 5%

12-03-00863-019B A-022312-19 Mastic Black Tar-Like 4% Chrysotile 96% Non-Fibrous

12-03-00863-01OA A-022312-10 Tile Gray Vinyl 4% Chrysotile 96% Non-Fibrous

Total Asbestos: 4%

12-03-00863-01OB A-022312-10 Mastic Black Tar-Like 3% Chrysotile 97% Non-Fibrous

Total Asbestos: 3%

12-03-00863-024 A-022312-24 Tan Vinyl 5% Chrysotile 95% Non-Fibrous

12-03-00863-033A A-022312-33 Tile Tan Vinyl 5% Chrysotile 95% Non-Fibrous

12-03-00863-033B A-022312-33 Mastic Black Tar-Like 4% Chrysotile 96% Non-Fibrous

12-03-00863-044A A-022312-44 Tile Light Brown Vinyl 2% Chrysotile 98% Non-Fibrous

Total Asbestos: 2%

12-03-00863-046A A-022312-46 Tile Tan Vinyl 5% Chrysotile 95% Non-Fibrous

12-03-00863-046B A-022312-46 Mastic Black Tar-Like 2% Chrysotile 98% Non-Fibrous

12-03-00863-047A A-022312-47 Tile Light Brown Vinyl 2% Chrysotile 98% Non-Fibrous

Environmental Hazards Services, L.L.C

Report Number: Client Number: 25-3802 12-03-00863

Project/Test Address: 1042-A

Lab Sample

Number

Client Sample

Number

Lab Gross Description Asbestos Other

Material

Layer Type

12-03-00863-049A A-022312-49 Tile Tan Vinyl 4% Chrysotile 96% Non-Fibrous

12-03-00863-049B A-022312-49 Mastic Black Tar-Like; Brown 2% Chrysotile 98% Non-Fibrous

Adhesive

Chrysotile present in black tar-like material.

12-03-00863-050A A-022312-50 Tile Light Brown Vinyl 2% Chrysotile 98% Non-Fibrous

12-03-00863-052A A-022312-52 Tile Tan Vinyl 4% Chrysotile 96% Non-Fibrous

12-03-00863-052B A-022312-52 Mastic Black Tar-Like 3% Chrysotile 97% Non-Fibrous

Total Asbestos: 3%