1. CONTRACT ID CODE PAGE OF PAGES
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1 2
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)
0005 02 June 2017 2117857***B29
6. ISSUED BY CODE HSCG85 7. ADMINISTERED BY (If other than Item 6) CODE
USCG COMMAND
Surface Forces Logistics Centers, C&PD2-LREPL 1301 Clay Street, Suite 800N, Oakland, CA 94612
SAME AS BLOCK #6
8. NAME AND ADRESS OF CONTRACTOR (no., street, county, State and ZIP Code) √ 9.A AMENDMENT OF SOLICITATION NO.
TO ALL PROSPECTIVE OFFERORS
HSCG85-17-R-P45B29
9B. DATE (SEE ITEM 11)
25 April 2017
10A. MODIFICATION OF CONTRACT/ORDER
NO. ?
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended. Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods: (a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the Offer submitted: or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEGEMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS,
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT/.ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc) SET FORTH IN ITEM 14, PURSUANT TO AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority).
E. IMPORTANT: Contractor is not, is required to sign this document and return 1 copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
SUBJECT: RFP No. HSCG85-17-R-P45B29 USCGC BERTHOLF (WMSL 750), Dockside Repairs FQ4 FY17
The purpose of this amendment is to:
1. Extend the solicitation end date from June 6, 2017, 1:00 p.m. Pacific time to June 15, 2017, 1:00 p.m. Pacific time.
SEE PAGE 2 FOR ADDITIONAL DESCRIPTION
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print) 16A NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
Wilma L. Estrada, Contracting Officer 15B. CONTRACTOR/OFFEROR 15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 16C. DATE SIGNED
BY
(Signature of person authorized to sign) (Signature of Contracting Officer)
NSN 7540-01-152-8070 30-105 STANDARD FORM 30 (REV. 10-83)PREVIOUS
EDITION UNUSABLE Prescribed by GSA, FAR (48 CFR) 53.243
HSCG85-17-R-P45B29
USCGC BERTHOLF (WMSL 750) Dockside Repairs FQ4 FY17 Amendment No. 0005
2. To reply to the following Requests for Clarification:
Question 1: This is in reference to work item D-17; Cofferdam, Install; Amendment 0001, Answer 1: The response in this amendment is directing the contractor to Clean and Inspect ONLY one CORD at a time. This would have a significant negative effect for WI-017 if this prevent the contractor from installing all 5 cofferdams and one plug at the same time?
If this is the case, the situation would have the divers conducting 6 individual installations and 6 removal evolutions, basically 12 days of divers does not seem to be the most cost effective.
Please advise if the contractor can install all the cofferdams at one time, including removal?
Answer to Question 1: Fire Main (FM) supply Seachests (SC) (each has their own independent SC) are independent of the A/C Seachests. At least 02 FM pumps need to be available at a time.
Could achieve in two groupings (03 Fire pumps (FPs), 02 FPs).
Question 2: This in reference to work item D-21; Passing Window Frame, Renew: Paragraph 3.2.3: Is NAVSEA drawing 804-1749004, called out in work item paragraph 3.2.3 to use as guidance, available?
Answer to Question 2: Yes. A copy of the drawing will be sent to all potential Offerors who have already requested and received the initial CD of drawings.
Question 3: This is in reference to Work Item D-12; Compressed Air Receivers, Clean, Inspect and Hydrotest; Paragraph 3.7: Is intent to preserve the air receivers or only perform touch-up/new & disturbed preservation?
Answer to Question 3: Yes, the intent of this item is to touch up paint damaged by inspection processes. The Coast Guard does not intend to renew the exterior paint on the receiver.
Question 4: This is in reference to Work Item D-04; Ship Service Diesel Generator, Exhaust Piping, Commercial Clean: Paragraph 3.6: When referencing the provided drawings, portions of the SSDG #1 and #2 exhaust arrangements are missing.
Please provide the following drawings as referenced in 750-WMSL-259-019
- Reference 10: Incin & DG Intake & Comb Exh Arr, Dets & L/M Abv 02 Lvl, ASC259019
- Reference 11: Incin & DG Intake & Comb Exh Arr, Dets & L/M Blw 2nd Deck, ASC259015 Answer to Question 4: A copy of the Drawings will be sent to all potential Offerors who have already requested and received the initial CD of drawings.
Question 5: This is in reference to Work Item D-01; Main Gas Turbine (MGT) Water Wash Tank, Clean, Inspect and Hydro; Paragraph 3.5: Please provide The Danco Relief Valve Label Plate Data.
Answer to Question 5:
Label Plate Data:
Set pressure: 75 Set Range:75/100 Inlet loss max: 21.75 ID Number: BCSZZ06SEE-24471
ACCUM PRESS: 87
Blowdown Press: 64 Back pressure max: 7.5 Drawing #: D1000
400 SCFM
Temp: 425 F