USCGC WAESCHE_Maintenance and Repair 1_March_2010_Rev 0.pdf
PDF 13 MB Posted
- Attached to
- Maintenance & Repair Period 1 on USCGC WAESCHE
- Solicitation number
- HSCG8510R610940
About this file
Specifications
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AMEND 0004 TO SOL.doc | DOC document | |
| AMEND 0003 TO SOL.doc | DOC document | |
| W24193-006_RecC.pdf | ||
| REV 1 Summary of Changes.pdf | ||
| 750-WMSL-582-501 Rev C.pdf | ||
| REVISED SCHEDULE B FOR AMEND 0003.doc | DOC document | |
| USCGC WAESCHE_Maintenance and Repair 1_March_2010_Rev 1.pdf | ||
| CAPTURE NET MODS.jpg | JPG image | |
| AMEND 0002 TO SOL.doc | DOC document | |
| AMEND 0001 TO SOL.doc | DOC document | |
| FINAL WASCHE MR 1 SOLICITATION.doc | DOC document | |
| PRESOLICITATION NOTICE.doc | DOC document |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifications for the Maintenance and Repair 1
USCGC WAESCHE (WMSL-751)
March 2010 Rev 0
UNITED STATES COAST GUARD
SURFACE FORCES LOGISTICS CENTER
OAKLAND DETACHMENT
RONALD V. DELLUMS FEDERAL BUILDING
1301 CLAY STREET, SUITE 807N
OAKLAND, CALIFORNIA 94612-5249
Specifications for the Maintenance and Repair 1 of March 2010 USCGC WAESCHE (WMSL-751) Rev 0
Table of Contents
Item SWBS Description Page
Vessel Description iii
Consolidated List of References v
Consolidated List of Government Furnished Property xv
General Requirements — Dockside, Home Port xviii
D-1 04100 Production Control, Gantt Bar Chart Provide 1
D-2 10100 Tank Cleaning Safe for Personnel – Safe for Hotwork 3
D-3 16700 Aft Damage Control Repair Locker Escape Scuttle 9
D-4 16700 Forward Damage Control Repair Locker Escape Scuttle 22
D-5 18400 Pilot House Top Structural Mods 31
D-6 20200 AFFF Power and MCMS Wiring 37
D-7 30000 Multi-Cable Transit Install and Cableway Support 49
D-8 32000 Fuel Valve Motor Actuator and Controls Install 56
D-9 33000 Overhead Lighting Fixture Mods 67
D-10 33000 Toilet/Shower and Stateroom Compartment Step Light Additions 76
D-11 44000 SCIF & Exterior Comms Power Distribution Install 85
D-12 44100 Hydra Frequency Reprogramming 92
D-13 50200 MPC Annex Ventilation Duct and Electrical Mods 96
D-14 53000 Deionization Helo Water Wash Install 101
D-15 54000 Fuel Oil Transfer Piping and Manifold Mods 152
D-16 55500 AFFF to CMWD Cross Connect Piping Install 228
D-17 58200 Towline Platform 248
D-18 58300 Capture Net Mods 253
D-19 58300 Starboard Boat Davit Mods 257
D-20 58800 Forward Asist Stops Mod 262
D-21 60000 MPC Lighting Mods 272
D-22 61300 03 Level Handrail/Life Raft Mods 277
D-23 63400 Deck Coverings (Interior Polymeric) Renew 283
D-24 64000 Two-High Berth Unit Addition to Stateroom 3-28-2-L 286
D-25 64100 Mission Module to Stateroom Conversion 304
D-26 64200 CPO Stateroom Ripout 319
D-27 64200 HF Transmitter Mechanical & Electrical Outfit Install 326
D-28 86351 Temporary Services, Dockside, Home Pier 337 i
Definite work items are identified by a “D” preceding the item number in the table above. Optional work items are designated by an “O” and shall be individually priced for possible performance.
ii
CUTTER DESCRIPTION — USCGC WAESCHE (WMSL 751)
[Design Class: 418-WMSL]
Hull Characteristics:
Length Overall 418’ 0” Length Between Perpendiculars 390’ 0” Maximum Beam (@ 13’ 6” DWL) 54’ 0” Beam @ 01 Level 47’ 9-1/8” Depth (01 Level @ side to Baseline) 39’ 2-3/4” 01 Deck Camber Foredeck 1/4” in 1’-0” Frame Spacing FWD OF FR 9 = 2’-3”
FR 9–FR 10 = 6’-9”
FR 10–FR 98 = 4’-1”
FR 98–FR 99 = 3’-8”
Minimum Berth Depth 20’ 0” Height of highest projection (above DWL) Approximately 119’ Draft, Design 14.40’ Design Displacement 3925 long tons
Maximum Tank Capacities (gallons):
Diesel Oil (95%) 220,359 Fresh Water (100%) 12,454 JP-5 Fuel (95%) 35,182
Hull Materials:
HSLA-80 Steel……………………………………………… 01 Level Stringer Strake Plating aft Fr21.5, 01 Level Plating Frames 43 to 52, 01 Level Shell Sheer Strake Plating aft Fr 21.5, and Deckhouse Fashion Plates at 01 Level and at Main Deck aft
ABS EH 36 Steel ……………………………………….…… Shell Plating Strakes at Turn of the Bilge
5456 Aluminum……………………………………………….. Mast
The remainder of hull structure is ABS AH 36
Machinery Characteristics:
Type of Propulsion: CODAG Two Diesel Engines; MTU 20V, 20-cylinder 9,730 SHP each One Gas Turbine; General Electric LM2500; 29,500 SHP Two Controllable Pitch Propellers; Rolls-Royce 5 blade, 14’ 0” diameter; 229 RPM max Two Reduction Gears; RENK One Cross Connect Gear, RENK Bridge, local, and Engine Room remote control of turbines, diesels, and propellers
Electrical Characteristics:
Three 1360 kW, 450 V, 60 Hz, 3 Phase, 1800 RPM Caterpillar 3512B diesel engines with Baylor ship service generators Seven MIL-C-24368/2 (NATO) shore power receptacles, 400 A each iii
CUTTER DESCRIPTION — USCGC WAESCHE (WMSL 751) (cont’d)
Armament:
One Mk 110 Bofors 57 mm single gun mount Four 50 cal Machine guns Two Mk36 Mod 12 SRBOC Launchers One Mk 53 Mod 4 NULKA Decoy Launcher One Mk 15 Mod 21 Block 1B CIWS
Complement:
Normal:
19 Officers 13 Chief Petty Officers 94 Enlisted 126 Total 148 Total Berths Crew is comprised of male and female personnel
Controlled Access Spaces:
02-29-0-C OPCEN
02-38-0-C COMM/MEES
02-40-1-C MPC
02-38-1-C MPC ANNEX
02-32-1-C SCIF
1-41-3-Q XMTR ROOM
1-36-1-Q LAN ROOM
iv
CONSOLIDATED LIST OF REFERENCES
Drawings
7269326 Rev C, Scif Shipalt (Ssee Inc E) WMSL 750 HVAC Modifications 7269326, Rev C, Scif Shipalt (Ssee Incr E) WMSL 750 HVAC Mods 750-WMSL-065-001, Rev -, Nsc Tracking Sheet 750-WMSL-085-004, Rev. B, Tank Capacity Curves 750-WMSL-085-008B, Rev -, Compartment Testing Drawing (Nsc 2 SRD) (ASC085017B) 750-WMSL-100-001, Rev J, General Arrangement 750-WMSL-100-017, Rev. G, Unit 1310 Structure–Inner Bottom to 1st Platform–FR 22 to FR 35 750-WMSL-100-019, Rev E, Unit 1330 Structure, Second Deck to Main Deck, Frame 22 to Frame 35 750-WMSL-100-021, Rev. C, Unit 2100 Structure–Inner Bottom–FR 35 to FR 44 750-WMSL-100-022, Rev. F, Unit 2110 Structure–Inner Bottom to 1st Platform–FR 35 to FR 44 750-WMSL-100-023, Rev. E, Unit 2120 Structure–1st Platform to 2nd Deck–FR 35 to FR 44 750-WMSL-100-026, Rev. E, Unit 2200 Structure–Inner Bottom–FR 44 to FR 52 750-WMSL-100-027, Rev. G, Unit 2210 Structure–Inner Bottom to 1st Platform- FR 44 to FR 52 750-WMSL-100-035, Rev F, Unit 2340 Structure- Mn Dk to 01 Lvl- FR 52 to FR 64 750-WMSL-100-042, Rev E, Unit 3230 Structure, Second Deck to Main Deck, Frame 76 to Frame 88 750-WMSL-101-001, Rev B, Standard Structural Details 750-WMSL-101-002, Rev. G, Compartment and Access Drawing Inner Bottom 750-WMSL-101-003, Rev. E, Compartment and Access Drawing Tank Top 750-WMSL-101-005, Rev. F, Compartment and Access Drawing Second Deck 750-WMSL-101-006, Rev F, Compartments and Access, Main Deck 750-WMSL-101-007, Compartment and Access Drawing 01 Level 750-WMSL-101-008, Compartment and Access Drawing 02 Level and Above 750-WMSL-101-016, Rev. E, Scantling Sections 750-WMSL-167-001, Rev. C, Manhole List, Installation and Fabrication Details, Ship Wide 750-WMSL-167-003, Rev B, Hatch and Scuttle List, Ship Wide 750-WMSL-185-500, Rev C, Scif Shipalt Electrical Distribution Power Panels & Foundations 750-WMSL-185-501 Rev -, Scif Shipalt Miscellaneous Auxiliary System Foundations 750-WMSL-185-501 Rev A, Scif Shipalt Miscellaneous Auxiliary System Foundations 750-WMSL-185-503, Rev -, Asist Stops Arrangement & Details 750-WMSL-185-504, Rev -, Scif Power Panel Modifications & Foundations 750-WMSL-300-003, Cable Routing List of Points 750-WMSL-300-004, Power Sys–List of Feeders & Mains 750-WMSL-300-029, Rev C, Unit 2340–Mn Dk–FR 52 to FR 64 Arrangement of Electrical
Equipment 750-WMSL-300-048, Unit 4420–01 Lvl–FR 52 to FR 67 Arrangement of Electrical Equipment 750-WMSL-300-500 Rev D, 750 WMSL Shipalt Multi-Cable Transit Block & Wireway Installation 750-WMSL-300-503 Rev A, Scif Shipalt WMSL 750 Multi-Cable Transit Block for Fwd EHF
Antenna Cables 750-WMSL-304-026, Rev B, Unit 2340–Mn Dk–FR 52 to FR 64 Wireway Arrangement and Details 750-WMSL-304-057, Rev (-), NSC3AF Unit 2340-Mn Dk–FR52 to FR64 Wireway Arrangement and
Details 750-WMSL-305-003, Label Plate List–Lighting Systems 750-WMSL-320-018, Power Sys Deck Plan–02 Level and Above 750-WMSL-320-503, Rev A, Vital Power Panel in Transmitter Room 750-WMSL-320-504 Rev -, Scif Shipalt WMSL 750 Transmitter & LAN Room Multi-Cable Transit
(Mct) Instl 750-WMSL-330-003, Lighting Sys–Feeders Deck Plan Wiring Diagram 750-WMSL-330-023, Lighting Sys Deck Plan–02 Level and Above 750-WMSL-330-500 Rev D, Scif Shipalt WMSL 750 Transmitter Room Power and Lighting
Modifications v
750-WMSL-330-500, Rev D, Transmitter Room Power & Lighting 750-WMSL-330-SKT Rev A, 750 WMSL Shipalt Low Level Lighting 750-WMSL-504-001, List of Sensors 750-WMSL-504-002, List of Instruments 750-WMSL-506-001, Rev. E, Overflow/Air Escapes Sounding Tubes Diagram 750-WMSL-506-011, Rev C-1-4, Overflow/Air Escapes/Sounding Tubes–Unit 1310 750-WMSL-506-012, Rev. A, Overflow/Air Escapes/Sounding Tubes–Unit 1320 750-WMSL-506-013, Rev. A, Overflow/Air Escapes/Sounding Tubes–Unit 1330 750-WMSL-506-014, Rev. A, Overflow/Air Escapes/Sounding Tubes–Assembly 1340 750-WMSL-506-037, Rev. A, Overflow/Air Escapes/Sounding Tubes–Assembly 4110 750-WMSL-506-038, Rev-, Overflow/Air Escapes/Sounding Tubes–Assembly 4210 750-WMSL-506-041, Rev B, Ovrfl/Air Escapes/Sounding Tubes- Unit 2340 750-WMSL-506-211, Overflow / Air Escapes / Sounding Tubes Unit 2110 750-WMSL-506-212, Overflow / Air Escapes / Sounding Tubes Unit 2120 750-WMSL-508-001, Piping and Machinery Insulation Schedule and L/M 750-WMSL-512-034, Rev B, Vent & Air Cond Arr Mn Dk Unit 2340 750-WMSL-512-070, Rev -, NSC3AF Vent & Air Cond Arr Mn Dk Unit 2340 750-WMSL-512-501 Rev B, Scif Shipalt WMSL 750 HVAC Modifications 750-WMSL-512-503 Rev D, Scif Shipalt WMSL 750 Transmitter Room HVAC Modifications 750-WMSL-512-503, Rev D, Scif Shipalt Transmitter Room (Ex Cpo) HVAC Rip-Out 750-WMSL-516-014, Rev B, Chilled Water- Unit 2340 750-WMSL-521-025, Rev A, Firemain–Unit 2340 750-WMSL-521-044, Rev A, NSC3AF Firemain- Unit 2340 750-WMSL-523-025 Rev A, Washdown Countermeasure- Unit 2340 750-WMSL-523-500 Rev B, Scif Shipalt WMSL 750 Mods to Wdcm System on Pilot House Top 750-WMSL-526-005, Deck Drain System Schematic 750-WMSL-526-018, Rev B, Weather Deck Drains- Unit 2340 750-WMSL-526-021, Weather Deck Drains–Unit 3140 750-WMSL-526-036, Rev -, NSC3AF Weather Deck Drains- Unit 2340 750-WMSL-530-001, Potable Water Systems Diagram 750-WMSL-530-016, Potable Water–Unit 2320 750-WMSL-530-017, Potable Water–Unit 2330 750-WMSL-530-018, Rev B Potable Water- Unit 2340 750-WMSL-530-030, Potable Water–Unit 4420 750-WMSL-530-036, Rev -, NSC3AF Potable Water- Unit 2340 750-WMSL-540-001, Rev. E, Fuel Oil Diagram 750-WMSL-540-005, Rev. B, Fuel Oil System Schematic 750-WMSL-540-008, Rev. B, Fuel/Oil Transfer–Unit 1310 750-WMSL-540-011, Rev. B, Fuel/Oil Transfer–Unit 2100 750-WMSL-540-014, Rev. C, Fuel/Oil Transfer–Unit 2110 750-WMSL-540-019, Rev. A, Fuel/Oil Transfer–Unit 2200 750-WMSL-540-021, Rev. D, Fuel/Oil Transfer–Unit 2210 750-WMSL-540-026, Rev-A, Fuel System–Unit 2230 750-WMSL-542-009, Rev B, JP-5 System–Unit 2340 750-WMSL-551-001, Compressed Air Diagram 750-WMSL-551-037, Compressed Air–Unit 4420 750-WMSL-582-501, Rev A, Towline Platform Arrangement and Details 750-WMSL-583-500, Boat Davit Mods 750-WMSL-583-501, Rev -, Boat Capture Net Modification 750-WMSL-588-006, Rev C, Helo Capture/Handling Arr & Installation Details 750-WMSL-593-001, Rev. G, Bilge and Oil Pollution Control System Diagram 750-WMSL-600-010, Rev B, Plan of Second Deck Port 750-WMSL-600-033, Rev B, Fabrication and Installation of Hull Outfit Design, Unit 3230 750-WMSL-612-500 Rev B, Scif Shipalt WMSL 750 Modifications of Railings & Life Rafts Iwo Aft
EHF Antenna vi
750-WMSL-612-501 Rev A, Scif Shipalt Modifications of Railings & Life Rafts Iwo Aft UHF Antenna
750-WMSL-621-019, Rev B, Overhead & Bhd Sheathing Mn Dk FR 36 to FR 64 750-WMSL-623-002, Rev B, Vertical Ladder and Ladder Rung List and Details Ship Wide 750-WMSL-631-002, Rev H, Paint Schedule 750-WMSL-634-001, Rev D, Deck Covering Schedule 750-WMSL-635-002, Rev E, Insulation Arrangements and Details Thermal, Acoustic and Fire 750-WMSL-641-500 Rev A, Scif Shipalt Compartment Conversion, Mission Module to Officer’s
Stateroom 750-WMSL-642-500 Rev -, Scif Shipalt Cpo Stateroom Rip-Out 750-WMSL-642-500, Rev A, Scif Shipalt Cpo Stateroom Rip-Out 8177114 Rev D, Scif Shipalt (EHF) WMSL 750 Lighting Modifications 8177126 Rev E, Scif Shipalt (EHF) WMSL 750 Fwd EHF Antenna Structural Mods A-A-50552, Fittings for Cable, Power, Electrical and Conduit, Metal, Flexible.
ASC 801-001B, Rev-; Booklet of General Plans NSC2 ASC100314, Rev G, Unit 3140 Structure, Main Deck to 01-Level, FR 64 to FR 76 ASC100324, Rev F, Unit 3240 Structure, Main Deck to 01-Level, FR 76 to FR 82 ASC100422 Rev E, Unit 4220 Structure – 02 Lvl and Above – FR 33 to FR 44 ASC100442 Rev C, Unit 4420 Structure – 01 Level and Above – FR 52 to FR 67 ASC101001, Rev B, Standard Structural Details ASC180413 Rev B, Foundation Arrangement Dwg Design Unit 4130 Bklt No. 1 ASC320011 Rev C, Power System HVAC Deck Plan ASC330005 Rev B, Lighting System Deck Plan: First Platform–Forward of Frame 36 ASC330006 Rev B, Lighting System Deck Plan: First Platform and Below–Aft of Frame 64 ASC330007 Rev C, Lighting System Deck Plan: Second Deck–Forward of Frame 52 ASC330008 Rev B, Lighting System Deck Plan: Second Deck–Aft of Frame 52 ASC330008, Rev B, Lighting System Deck Plan, Second Deck, Aft of FR 52 ASC330009 Rev B, Lighting System Deck Plan: Main Deck–Forward of Frame 52 ASC330010 Rev C, Lighting System Deck Plan: Main Deck–Aft of Frame 52 ASC330011 Rev B, Lighting System Deck Plan: 01 Level–Forward of Frame 44 ASC330012 Rev B, Lighting System Deck Plan: 01 Level–Aft of Frame 44 ASC330013 Rev B, Lighting System Deck Plan 02 Level and Above ASC433001 Rev B, General Ancg, Flight Deck Ancg & Intership Ancg Sys Deck Plan ASC434003 Rev A, Entertainment (Radio & Tv) Distribution Sys Deck Plan ASC480001 Rev B, Integrated Fire Control System Cable Block Diagram ASC505003, Rev B, List of Power Operated Valves ASC505004, Rev A, Piping Material Schedule ASC509001 Rev -, HVAC Insulation Schedule and L/M ASC509001 Rev–, HVAC Insulation Schedule and L/M ASC512007 Rev A, Vent and Air Conditioning Standard Instruction ASC512314, Rev D, Vent and Air Cond. Arr Mn Dk Unit 3140 ASC512324, Rev B, Vent and Air Cond. Arr Mn Dk Unit 3240 ASC512422 Rev B, Vent & Air Cond Arrg’t Unit 4220 ASC516314-CW, Rev B, Chilled Water – Unit 3140 ASC516314-RF, Rev B, Refrigeration Piping – Unit 3140 ASC516314-RF-PD, Rev C, Refrigeration Piping – Unit 3140 Pipe Detail Wkg ASC516324-CW, Rev A, Chilled Water – Unit 3240 ASC516324-CW-PD, Rev B, Chilled Water – Unit 3240 Pipe Detail Wkg ASC516324-CW-PD, Rev C, Chilled Water – Unit 3140 Pipe Detail Wkg ASC523314-CM PD, Rev B, Pipe Detail ASC523314-CM, Rev A, Washdown Countermeasure Unit 3140 ASC523324-CM PD, Rev B, Pipe Detail ASC523324-CM, Rev A, Washdown Countermeasure Unit 3240 ASC555001, Rev E, Foam System Diagram ASC555004, Rev A, Label Plate List – AFFF, CO2, Chemical-Apc Fire Ext Supply Piping System vii
ASC555011, Rev B ACTIVE Fire Protection Foam System Schematic ASC555233-AF PD, Rev -, Pipe Detail ASC555233-AF, Rev B, Foam System Unit 2330 ASC555313-AF PD, Rev B, Pipe Detail ASC555313-AF, Rev A, Foam System Unit 3130 ASC621001 Rev D, Joiner Bulkheads Typical Details ASC621017, Rev A, Overhead Sheathing, 2nd Dk, FR 64 Aft ASC621018 Rev -, Overhead Sheathing Main Deck, Fp to 36 ASC631002, Rev H, Paint Schedule ASC635002 Rev E, Insulation Arr & Details Thermal, Acoustic, & Fire ASC635002, Rev E, Insulation, Arrangements & Details, Thermal, Acoustic, & Fire ASTM 1056-00, Standard Specification for Flexible Cellular Materials–Sponge or Expanded Rubber ASTM F1387-99, Standard Specification for Performance of Piping and Tubing Mechanically
Attached Fittings American National Standards Institute (ANSI) B16.11-2002, Forged Steel Fittings, Socket-Welding and Threaded, 2/1/2002 American Society of Mechanical Engineers (ASME) requirements for “UM” code Unfired Pressure
Vessels, Section VIII, Division 1 American Society of Test Engineers (ASTM) A-312 Type 304L SMLS Schedule 40S DOD-STD-2003, Electric Plant Installation Standard Methods for Surface Ships and Submarines ETSA Memo No NSC-002, Shipboard Piping Cleaning Procedures INDAL Technologies Drawing 8401-027, Rev A, Frame, Shock Absorber INDAL Technologies Drawing PR0371101-003, Rev -, Dual Asist Layout USCG Deepwater–Nsc INDAL Technologies, Drawing 8401-020, Rev B, Shock Absorber Assembly INDAL Technologies, Drawing 8401-026, Rev -, Shock Absorber Assembly Institute of Electrical and Electronic Engineers (IEEE), Standard 45, 12 Sep 2002 Recommended
Practice for Electrical Installations on Shipboard International Standards Organization (ISO) 8573-1 MIL-A-24179A, Adhesive, Flexible Unicellular Plastic Thermal Insulation MIL-A-3316C, Adhesives, Fire-Resistant Thermal Insulation MIL-C-20079H, Cloth, Glass; Tape, Textile Glass; & Thread, Glass & Wire-Reinforced Glass MIL-C-24640/2, Lightweight Power Cable MIL-DTL-24441C/29, Paint, Epoxy-Polyamide, Green Primer, Formula 150, Type IV MIL-DTL-24643/16E, Cable, Electrical, 1000 Volts, Type Lstsgu MIL-DTL-24643/17E, Cable, Electrical, 1000 Volts, Type Lsfsgu MIL-DTL-24643/20E, Cable, Electrical, 1000 Volts, Type LS7SGU MIL-E-24635, Coating Systems, Weather-Resistant, Exterior Use MIL-F-1183, Rev J; Fittings, Pipe Cast Bronze Silver-Brazing, 5/5/1987 MIL-I-3064A, Insulation, Electrical, Plastic-Sealer MIL-PRF-1149, Rev D; Gasket Materials, Synthetic Rubber, 50 and 65 Durometer Hardness, 6/10/1998 MIL-PRF-23236C, Coating Systems for Ship Structures MIL-S-19622/1A, Stuffing Tubes, Straight, Nylon MIL-S-19622/2B, Stuffing Tubes, 90 Degrees, Nylon MIL-STD-1310, Rev G, Standard Practice for Shipboard Bonding, Grounding, And Other Techniques for Electromagnetic Compatibility and Safety MIL-STD-1310G, Standard Practices for Shipboard Bonding, Grounding, And Other Techniques for
Electromagnetic Compatibility and Safety MIL-STD-1627, Rev C; Bending of Pipe or Tube for Ship Piping System, 9/30/1994 MIL-STD-1683B (SH), Connectors and Jacketed Cable, Electric, Selection Standard for Shipboard
Use MIL-STD-1689, Rev A; Fabrication, Welding and Inspection of Ships Structure, 11/23/1990 MIL-STD-2035(SH), Rev A; Nondestructive Testing Acceptance Criteria, 5/15/1995 MIL-STD-22, Notice 3, Rev D; Welded Joint Design, 3/21/1991 MIL-T-16420, Rev K; Tube, Copper-Nickel Alloy, Seamless and Welded (Copper Alloys 715 &706), viii
9/16/1988 MIL-T-24104, Specifications for Seamless Drawn Copper Alloy C12200 MLCPAC Standard Specification 074, Welding and Allied Processes, 3/21/2003 MLCPAC Standard Specification 085.1, General Requirements for Drawing Preparation MLCPAC Standard Specification 304.1, Shipboard Electrical Cable Test, 3/1/2000 MLCPAC Standard Specification 304.2, Shipboard Electrical Cable Removal, Relocation, Splice, Repair, And Installation, 3/1/2000 MLCPAC Standard Specification 634, Deck Covering Renewal, 3/1/2000 NAVSEA 0900-LP-001-7000, Fabrication and Inspection of Brazed Piping Systems NAVSEA Drawing 803-1385866, Penetrations; Bulkhead and Deck NAVSEA Drawing 803-5001003, Ball Valves NAVSEA Drawing 804-1385781, Pipe Hangers for Surface Ships (Superseding NAVSEA Dwg. 810-
1385781) NAVSEA Drawing 804-5959214, Rev -, 9/20/84, Insulation, Piping NAVSEA Drawing 810-1385880, Fittings, Cu-Ni Alloy, Slip on Sleeve NAVSEA Dwg 804-1385781, Pipe Hangers for Surface Ships (Superseding NAVSEA Dwg. 810- NAVSEA Dwg 810-1385880, Fittings, Cu-Ni Alloy, Slip on Sleeve NAVSEA S2803-980208 and S2803-980209, Label Plate Standards, NAVSEA S9074-AR-GIB-010/278, Requirements for Fabrication Welding & Inspection & Casting
Inspection & Repair for Machinery, Piping & Pressure Vessels NAVSEA T9074-AS-GIB-010/271, Requirements for Non-Destructive Testing Methods NAVSEA Technical Manual, Chapter 635, Thermal, Fire and Acoustic Insulation NAVSEA Technical Manual, S9088-RK-010, Chapter 505, Piping Systems, 12/1/2001 NAVSHIPS Drawing 803-1385714, Gate Valves Naval Ships’ Technical Manual, Chapter 635, Thermal, Fire and Acoustic Insulation QQ-N-281, Rev D(2); Nickel-Copper Alloy Bar, Rod, Plate, Sheet, Strip, Wire, Forgings. And
Structural and Special Shaped Sections, 10/23/1985 S9086-RK-STM-010, Naval Ships Technical Manual, Chapter 505; Para 505-6.8, Mechanically
Attached Fittings SP001078, Standard Mounting Methods for O&F Equipment TCTO HH-65C T71130, Hh-65C, U.S. Coast Guard Aviation Computerized Maintenance System
Technical Order TT-C-492C, Coating Compound, Paint Anti-Sweat TT-P-645B, Primer, Paint, Zinc-Molybdate, Alkyd Type The Society for Protective Coatings (SSPC), Surface Preparation Specification No.11 (SSPC-SP 11), 01 Sep 2000, Power Tool Cleaning to Bare Metal
Applicable Documents
15 USC §2601 to 2692, Toxic Substance Control Act (TSCA) 16 CFR §1303, Ban of Lead-Containing Paint and Certain Consumer Products Bearing Lead-
Containing Paint 29 CFR §1910, Occupational Safety and Health Standards 29 CFR §1915, Occupational Health and Safety Standards for Shipyard Employment 29 CFR §1926, Safety and Health Regulations for Construction 33 CFR §154, Facilities Transferring Oil or Hazardous Materials in Bulk 33 USC §1251 to 1387, Federal Water Pollution Control Act 33 USC §1342, National Pollutant Discharge Elimination System 33 USC §2701 to 2761, Oil Pollution Control Act of 1990 40 CFR §112, Oil Pollution Prevention 40 CFR §204, Noise Emission Standards for Construction Equipment 40 CFR §261, Identification and Listing of Hazardous Waste 40 CFR §262, Standards Applicable to Generators of Hazardous Waste 40 CFR §263, Standards Applicable to Transporters of Hazardous Waste 40 CFR §279, Used Oil Management Standards ix http://www.access.gpo.gov/uscode/title15/chapter53_.html http://www.access.gpo.gov/nara/cfr/waisidx_06/16cfr1303_06.html http://www.access.gpo.gov/nara/cfr/waisidx_06/16cfr1303_06.html http://www.access.gpo.gov/nara/cfr/waisidx_05/29cfr1910_05.html http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=29:7.1.1.1.5&idno=29 http://www.access.gpo.gov/nara/cfr/waisidx_05/29cfr1926_05.html http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=33:2.0.1.5.22&idno=33 http://www.access.gpo.gov/uscode/title33/chapter26_.html http://frwebgate.access.gpo.gov/cgi-bin/getdoc.cgi?dbname=browse_usc&docid=Cite:+33USC1342 http://www.access.gpo.gov/uscode/title33/chapter40_.html http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:21.0.1.1.7&idno=40 http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:24.0.1.2.10&idno=40 http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:25.0.1.1.2&idno=40 http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:25.0.1.1.3&idno=40 http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:25.0.1.1.4&idno=40 http://www.access.gpo.gov/nara/cfr/waisidx_06/40cfr279_06.html
40 CFR §300, National Oil and Hazardous Substances Pollution Contingency Plan 40 CFR §61, National Emission Standards for Hazardous Air Pollutants 40 CFR §761, Polychlorinated Biphenyls (PCB) Manufacturing, Processing, Distribution in
Commerce, And Use Prohibitions 42 USC §4851 to 4852, Residential Lead-Based Paint Hazard Reduction Act 42 USC §4901 to 4918, Noise Control Act (NCA) 42 USC §6901 to 6991(i), Resource Conservation and Recovery Act (RCRA) 42 USC §7401 to 7671(q), Clean Air Act 42 USC §9601 to 9675, Comprehensive Environmental Response, Compensation, And Liability Act
(CERCLA)
46 CFR PT 56, U.S. Department of Transportation, Piping Systems and Appurtenances, 10/1/2008 49 CFR §100-199, Hazardous Materials Transportation, Handling, And Storage Regulations 7 USC §136 to 136(y), Federal Insecticide, Fungicide, And Rodenticide Act (FIFRA) A-A-50552, Fittings for Cable, Power, Electrical and Conduit, Metal, Flexible.
API STD 607, Fire Test for Soft-Seated Quarter Turn Valves, 6/1/2005 ASME 16.9, Factory-Made Wrought Buttwelding Fittings, 12/7/2007 ASME B16.5, Pipe Flanges and Flanged Fittings Nps ½ Through Nps 24, 6/30/2009 ASME/ANSI B1.1-2003 Unified Inch Screw Threads (UN and UNR Thread Form) ASME/ANSI B18.2.2.2-1987, Square and Hex Nuts (Inch Series) ASME/ANSI B18.22.1-1965, Plain Washers ASTM 1056-00, Standard Specification for Flexible Cellular Materials–Sponge or Expanded Rubber ASTM A182, Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, And Valves and Parts for High-Temperature Service, 5/1/2009 ASTM A312, Standard Specification for Seamless, Welded, And Heavily Cold Worked Austenitic
Stainless Steel Pipes, 5/15/2009.
ASTM A403, Standard Specification for Wrought Austenitic Stainless Steel Piping Fittings, 11/1/2007 ASTM F 683-99, Standard Practice for Selection and Application of Thermal Insulation for Piping and
Machinery ASTM F467, Standard Specification for Nonferrous Nuts for General Use, 5/1/2008 ASTM F468, Standard Specification for Nonferrous Bolts, Hex Cap Screws, And Studs for General
Use, 5/1/2006 American Bureau of Shipping-Grade AH-36 Steel American National Standards Institute (ANSI) B16.11-2002, Forged Steel Fittings, Socket-Welding and Threaded, 2/1/2002 American National Standards Institute (ANSI) B16.9-86, Fittings, Factory-Made Wrought Steel
Buttwelding – 15 June 87 American Welding Society (AWS) D1.1/D1.1M:2006, 2008 Rev 08; Structural Welding Code–Steel, 20TH Edition American Welding Society (AWS) D3.5, Rev 93, 1/20/2001; Guide for Steel Hull Welding Asset Operation and Maintenance (O&M) Technical Manual – Volume 1 (Document Number:
K00010520 prepared by L-3 Communications Systems East) BUSHIPS 803-2226372, 21” 3 Dog Flush Watertight Scuttle BUSHIPS 803-2226372, 21” 3 Dog Watertight Scuttle with Raised Coaming COMDTINST M10360.3C, Coatings and Colors Manual COMDTINST 6260.21, Hazard Communications for Work Place Materials COMDTINST 9077.1, Equipment Tag-Out Procedure, Revision C COMDTINST 9077.1A; Equipment Tag-Out Procedure COMDTINST M10360.3, Rev C, 6/9/2006; Coatings and Colors Manual COMDTINST M10360.3B; Coatings and Color Manual COMDTINST M10360.3C, Coatings and Colors Manual COMDTINST M16478.1, Hazardous Waste Management Manual COMDTINST M16478.2, Procurement, Handling and Disposal of Polychlorinated Biphenyls COMDTINST M6260.16A, Asbestos Exposure Control Manual, Ch-1 COMDTINST M9085.1, U.S.C.G. Naval Engineering Computer Aided Design Standards.
California Code of Regulations, Title 22, Division 4, Environmental Health and 4.5, Environmental x http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:27.0.1.1.1&idno=40 http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:8.0.1.1.1&idno=40 http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:30.0.1.1.17&idno=40 http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?c=ecfr&sid=094a62612c31c4cade95984dfa2f2622&rgn=div5&view=text&node=40:30.0.1.1.17&idno=40 http://www.access.gpo.gov/uscode/title42/chapter63a_.html http://www.access.gpo.gov/uscode/title42/chapter65_.html http://www.access.gpo.gov/uscode/title42/chapter82_.html http://www.access.gpo.gov/uscode/title42/chapter85_subchapteri_.html http://www.access.gpo.gov/uscode/title42/chapter85_subchapteri_.html http://www.access.gpo.gov/uscode/title42/chapter85_subchapteri_.html http://products.ihserc.com/shoppingcart/controller?callbackurl=Javascript%3Ans4%3Ddocument.layers%3Bif(ns4)%7bparent.window.close()%3B%7delse%7bopener.focus()%3B%7d&callapp=SPECS4&event=MediaSelect&sess=244221222&prod=SPECS4&GID=QZMCLCAAAAAAAAAA http://ecfr.gpoaccess.gov/cgi/t/text/text-idx?sid=094a62612c31c4cade95984dfa2f2622&c=ecfr&tpl=/ecfrbrowse/Title49/49tab_02.tpl http://www.access.gpo.gov/uscode/title7/chapter6_subchapterii_.html http://www.awspubs.com/ http://www.awspubs.com/ http://www.uscg.mil/ccs/cit/cim/directives/CI/CI_6260_21B.pdf http://cgweb.uscg.mil/G-C/G-CCS/G-CIT/G-CIM/DIRECTIVES/CI/CI_9077_1C.pdf http://www.uscg.mil/directives/cim/10000-10999/CIM_10360_3C.pdf http://www.uscg.mil/ccs/cit/cim/directives/cim/cim_16478_1b.pdf http://www.uscg.mil/ccs/cit/cim/directives/cim/cim_16478_2.pdf http://cgweb.uscg.mil/G-C/G-CCS/G-CIT/G-CIM/DIRECTIVES/CIM/CIM_6260_16A.pdf http://government.westlaw.com/linkedslice/default.asp?SP=CCR-1000
Health Standards for the Management of Hazardous Waste California Code of Regulations, Title 23, Waters California Health and Safety Code, Divisions 20, Miscellaneous Health and Safety Provisions, 26, Air
Resources, 37, Regulation of Environmental Protection, 103, Disease Prevention and Health Promotion, 104, Environmental Health.
Chapter 173-303, WASHINGTON Administrative Code Chapter 340, Oregon Administrative Rules DOD-I-24688, Insulation Panel, Thermal and Acoustic Absorptive, Open-Cell Polyimide DOD-STD-2003(series), Electrical Plan Installation Standard Methods for Surface Ships and
Submarines DOD-STD-2003, Electric Plant Installation Standard Methods for Surface Ships and Submarines DOD-STD-2003-(SH), Electric Plant Installation Standard Methods for Surface Ships and Submarines DOD-STD-2003-1 (NAVY), Chg 1, Electric Plant Installation Standard Methods for Surface Ships and Submarines (Cable) Section 1 of 5 DOD-STD-2003-1, Not 1; Electric Plant Installation Standard Methods for Surface Ships &
Submarines (Cable), Section 1 DOD-STD-2003-2, Not 1; Electric Plant Installation Standard Methods for Surface Ships &
Submarines (Equipment), Section 2 DOD-STD-2003-3 (NAVY), Chg 1, Electric Plant Installation Standard Methods for Surface Ships and Submarines (Penetrations) Section 3 of 5 DOD-STD-2003-3, Not 1; Electric Plant Installation Standard Methods for Surface Ships &
Submarines (Penetrations), Section 3 DOD-STD-2003-4, Not 1; Electric Plant Installation Standard Methods for Surface Ships &
Submarines (Cableways), Section 4 FCD LMAIM-1336-00, Accutronix Mx Pb DPV1 / Pa Field Unit, Installation & Operation Manual, Flowserve Limitorque Actuation Systems.
FED-STD-595C, Colors Used in Government Procurement Federal Specification FF-S-85D, Screw, Cap, Slotted and Hexagon Head, 3/10/2005 Federal Standard FED-STD-595B(1), Rev B, Not 1; Color Used in Government Procurement HYDRA Drawings Manual – Volume 2 IEEE STD 45-2002, Recommended Practice for Electrical Installations on Shipboard, 11OCT2002 Institute of Electrical and Electronic Engineers (IEEE), Standard 45, 12 Sep 2002 Recommended
Practice for Electrical Installations on Shipboard Institute of Electrical and Electronics Engineers (IEEE) Std 1580, 2001; Recommended Practice for
Marine Cable for Use on Shipboard and Fixed or Floating Platforms Institute of Electrical and Electronics Engineers (IEEE) Std 45, 2002; Recommended Practice for
Electrical Installations on Shipboard JA25-8541, Maintenance Manual, Machinery Control and Monitoring System (Mcms) Sperry Marine.
MIL-A-21016F, Adhesive, Resilient Deck Covering MIL-A-22262, Rev B, Amd 2; Abrasive Blasting Media Ship Hull Blast Cleaning MIL-A-24179A, Adhesive, Flexible Unicellular Plastic Thermal Insulation MIL-A-3316C, Adhesives, Fire-Resistant Thermal Insulation MIL-A-46106, Rev B, Amd 3; Adhesive-Sealants, Silicone, Rtv, One-Component MIL-C-17/191B, Cable, Radio Frequency, Flexible, Coaxial, 75 Ohm M17/191-00001 MIL-C-20079H, Cloth, Glass; Tape, Textile Glass; And Thread, Glass and Wire-Reinforced Glass MIL-C20079H, Cloth, Glass; Tape, Textile Glass; And Thread, Glass and Wire-Reinforced Glass II, Cl I MIL-D-18873, Rev B, Amd 3; Deck Covering Magnesia Aggregate Mixture MIL-D-23134, Rev A, Not 1; Deck Underlay and Covering, Insulating, Magnesia Aggregate Mixture MIL-DTL-24441C/29, Paint, Epoxy-Polyamide, Green Primer, Formula 150, Type IV MIL-DTL-24640, Rev B, Sup 1A Cables, Light-Weight, Electric, For Shipboard Use, General
Specification for MIL-DTL-24640/15D, Cable, Electric, 600 Volt, Light Weight, Multi-Pair Awg 22, Type 2XSAW
(Including Variation Type 2XSAOW) MIL-DTL-24640/16D, Cable, Electric, 600 Volt, Light Weight, Multi-Pair Awg 18, Type 2XSW xi http://government.westlaw.com/linkedslice/default.asp?SP=CCR-1000 http://government.westlaw.com/linkedslice/default.asp?SP=CCR-1000 http://www.leginfo.ca.gov/cgi-bin/calawquery?codesection=hsc&codebody=&hits=20 http://www.leginfo.ca.gov/cgi-bin/calawquery?codesection=hsc&codebody=&hits=20 http://www.leginfo.ca.gov/cgi-bin/calawquery?codesection=hsc&codebody=&hits=20 http://apps.leg.wa.gov/WAC/default.aspx?cite=173-303 http://arcweb.sos.state.or.us/rules/OARs_300/OAR_340/340_tofc.html http://www.assistdocs.com/search/document_details.cfm?ident_number=53815&StartRow=1&PaginatorPageNumber=1&doc%5Fid=FED%2DSTD%2D595&search%5Fmethod=BASIC http://ieeexplore.ieee.org/iel5/7947/21931/01019772.pdf?tp=&isnumber=21931&arnumber=1019772 http://ieeexplore.ieee.org/iel5/7947/21931/01019772.pdf?tp=&isnumber=21931&arnumber=1019772 http://shop.ieee.org/ieeestore/Product.aspx?product_no=SH95035 http://shop.ieee.org/ieeestore/Product.aspx?product_no=SH95035 http://www.assistdocs.com/search/document_details.cfm?ident_number=15260&StartRow=1&PaginatorPageNumber=1&doc%5Fnumber=22262&status%5Fall=ON&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=25183&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DA%2D46106&search%5Fmethod=BASIC http://assistdocs.com/search/document_details.cfm?ident_number=13093&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DD%2D18873&status%5Fall=ON&search%5Fmethod=BASIC http://assistdocs.com/search/document_details.cfm?ident_number=16052&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DD%2D23134&status%5Fall=ON&search%5Fmethod=BASIC http://assist.daps.dla.mil/Quicksearch/basic_profile.cfm?ident_number=17572 http://assist.daps.dla.mil/Quicksearch/basic_profile.cfm?ident_number=17572
MIL-DTL-24643, Rev B, Sup 1A; Cables and Cords, Electric, Low Smoke, For Shipboard Use, General Specification for
MIL-DTL-24643/15E, Cable, Electric, 1000 Volts, Type Lsdsgu MIL-DTL-24643/16E, Cable, Electrical, 1000 Volts, Type Lstsgu MIL-DTL-24643/17E, Cable, Electric, 1000 Volts, Type Lsfsgu MIL-DTL-24643/20E, Cable, Electrical, 1000 Volts, Type LS7SGU MIL-DTL-5624, Rev U; Turbine Fuel, Aviation, Grades JP-4 and JP-5 MIL-E-24635, Coating Systems, Weather-Resistant, Exterior Use MIL-F-1183, Rev J; Fittings, Pipe Cast Bronze Silver-Brazing, 5/5/1987 MIL-HDBK-299, Note 1; Cable Comparison Handbook Data Pertaining to Electric Shipboard Cable MIL-I-3064A, Insulation, Electrical, Plastic-Sealer MIL-I-742F, Insulation Board, Thermal, Fibrous Glass MIL-PRF-1149D, Gasket Materials, Synthetic Rubber, 50 and 65 Durometer Hardness MIL-PRF-16884, Rev L; Fuel, Naval Distillate MIL-PRF-23236C, Coating Systems for Ship Structures MIL-PRF-24613, Amd 2, Not 1; Deck Covering Materials, Interior, Cosmetic Polymeric MIL-PRF-24613A, Deck Covering Materials, Interior, Cosmetic Polymeric MIL-PRF-24758A(SH), Conduit System, Flexible, Weatherproof MIL-PRF-3135, Rev G, Amd 4; Deck Covering Underlay Materials MIL-PRF-3135H, Deck Covering Underlay Materials MIL-S-19622/1A, Stuffing Tubes, Straight, Nylon MIL-S-19622/2B, Stuffing Tubes, 90 Degrees, Nylon MIL-S-24235/17B, Stuffing Tubes, Metal, And Packing Assemblies for Electric Cables, Swage Type, Steel and Aluminum, For Deck and Bulkheads with Pipe Protection MIL-S-245235/17B, Stuffing Tubes MIL-STD- MS3456, Connectors, Plug, Electrical, Rear Release, Crimp Contact, An Type MIL-STD-1310, Rev G; Shipboard Bonding, Grounding, And Other Techniques for Electromagnetic
Compatibility and Safety MIL-STD-1310G, Standard Practices for Shipboard Bonding, Grounding, And Other Techniques for
Electromagnetic Compatibility and Safety MIL-STD-1625, Rev C, Chg Not 1; Safety Certification Program for Drydocking Facilities and
Shipbuilding Ways for U.S. Navy Ships MIL-STD-1627, Rev C; Bending of Pipe or Tube for Ship Piping System, 9/30/1994 MIL-STD-1689, Rev A, 11/23/1990; Fabrication, Welding and Inspection of Ships Structure MIL-STD-1689A (SH), Fabrication, Welding and Inspection of Ship’s Structures MIL-STD-1689A(SH), Fabrication Welding and Inspection of Ships Structure, 11/23/1990 MIL-STD-2035 (SH), Nondestructive Testing Criteria, 5/15/1995 MIL-STD-2035(SH), Rev. A; Nondestructive Testing Acceptance Criteria, 5/15/1995 MIL-STD-2035, Rev A; Nondestructive Testing Acceptance Criteria MIL-STD-22, Notice 3, Rev D; Welded Joint Design, 3/21/1991 MIL-STD-22D(3), Welded Joint Design, 3/21/1991 MIL-STD-22D, Welded Joint Design, 3/21/1991 MIL-STD-271, Requirements for Nondestructive Testing Methods, Section 4, Magnetic Particle
Testing, Section 5, Liquid Penetrant Testing, And Section 7, Eddy Current Testing MIL-STD-777E(SH), Schedule of Piping, Valves, Fittings, And Associated Piping Components for
Naval Ships MIL-T-16366, Rev F, Not 3; Terminal, Electrical Lug and Conductor Splices, Crimp Style MLCPAC Standard Specification 041, 1/1/2000; Production Control, Gantt Bar Chart MLCPAC Standard Specification 074, Welding and Allied Processes, 3/3/2006 MLCPAC Standard Specification 085.1, General Requirements for Drawing Preparation MLCPAC Standard Specification 304.1, 3/1/2000; Shipboard Electrical Cable Test MLCPAC Standard Specification 304.2, 3/1/2000; Shipboard Electrical Cable Removal, Relocation, Splice, Repair and Installation MLCPAC Standard Specification 634, 3/1/2000; Deck Covering Renewal MLCPac Standard Specification 304.1, Shipboard Electrical Cable Removal, Relocation, Splice, xii http://www.assistdocs.com/search/document_details.cfm?ident_number=17614&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DDTL%2D24643&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=17614&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DDTL%2D24643&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=5558&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DDTL%2D5624&search%5Fmethod=BASIC http://assistdocs.com/search/document_details.cfm?ident_number=68094&StartRow=1&PaginatorPageNumber=1&doc%5Fnumber=299&status%5Fall=ON&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=12122&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DPRF%2D16884&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=17523&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DPRF%2D24613&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=3698&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DPRF%2D3135&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=36209&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DSTD%2D1310&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=36209&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DSTD%2D1310&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=37023&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DSTD%2D1625&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=37023&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DSTD%2D1625&search%5Fmethod=BASIC http://www.assistdocs.com/search/document_details.cfm?ident_number=72749&StartRow=1&PaginatorPageNumber=1&doc%5Fid=MIL%2DSTD%2D2035&search%5Fmethod=BASIC http://assistdocs.com/search/document_details.cfm?ident_number=11765&StartRow=1&PaginatorPageNumber=1&doc%5Fnumber=16366&status%5Fall=ON&search%5Fmethod=BASIC http://cgweb.mlcpac.uscg.mil/mlcpv/Technical_Resources/MLCP_Resources/Standard_Specs/mlcpacstandspec041rev01.pdf http://cgweb.mlcpac.uscg.mil/mlcpv/Technical_Resources/MLCP_Resources/Standard_Specs/mlcpacstandspec_074_Mar03.pdf http://cgweb.mlcpac.uscg.mil/mlcpv/Technical_Resources/MLCP_Resources/Standard_Specs/mlcpacstandspec304-1.pdf http://cgweb.mlcpac.uscg.mil/mlcpv/Technical_Resources/MLCP_Resources/Standard_Specs/mlcpacstandspec304-2.pdf http://cgweb.mlcpac.uscg.mil/mlcpv/Technical_Resources/MLCP_Resources/Standard_Specs/mlcpacstandspec304-2.pdf http://cgweb.mlcpac.uscg.mil/mlcpv/Technical_Resources/MLCP_Resources/Standard_Specs/mlcpacstandspec634.pdf
Repair, And Installation, 3/1/2000 NAVSEA 0900-LP-001-7000, Fabrication and Inspection of Brazed Piping Systems NAVSEA 0900-LP-003-8000; Surface Inspection Acceptance Standards for Metals NAVSEA Drawing 803-1385866, Rev. E, Penetrations; Bulkhead and Deck NAVSEA Drawing 804-1385781, Pipe Hangers for Surface Ships, Rev. E NAVSEA S9074-AQ-GIB-010/248, Welding and Brazing Procedure and Performance Qualification NAVSEA S9074-AR-GIB-010/278, Requirements for Fabrication Welding & Inspection & Casting
Inspection & Repair for Machinery, Piping & Pressure Vessels NAVSEA Standard and Type Drawing 803-5001054, Rev, Hanger Pipe Design Install &
Arrangements NAVSEA Standard and Type Drawing 804-1385781 Rev E, Pipe Hangers for Surface Ships NAVSEA Standard and Type Drawing 804-1385781, Rev E, Pipe Hangers for Surface Ships NAVSEA Standard and Type Drawing 804-5773932, Rev A, Acoustic & Thermal Insulation for
Ducts NAVSEA Standard and Type Drawing 804-5959214, Rev -, 9/20/84, Insulation, Piping NAVSEA T9074-AS-GIB-010/271, Including Change Notice 1; Requirements for Non-Destructive
Testing Methods NAVSEA TM S9086-CH-STM-010, Ch. 074, Vol 1, Welding and Allied Processes, 1/31/2003 NAVSEA Technical Manual S9086-CH-STM-010, Ch 074, Welding and Allied Processes NAVSEA Technical Publication T9074-AS-GIB-010/271; Requirements for Nondestructive Testing
Methods NGSB Engineering Change Notice DW/DP00704, Rev -, Deletion of Overhead Sheathing in Crew
Staterooms NGSB Engineering Change Notice DW/DP00742, Rev -, Revised 4” Cmwd 101 NGSB RFS DE-000573, Rtu Shielding and Grounding NGSS/ECN DW/DV00161, Rev A, 4/30/2009 NSC Class Technical Specification Section 071, Access NSC Class Technical Specification Section 074, Castings, Welding, Mechanical Fastening and Allied
Processes NSC Class Technical Specification Section 078, Materials Requirements NSC Class Technical Specification Section 635; Thermal, Acoustic Absorptive, High Transmission
Loss and Fire Protection Insulation Treatment of Compartments for Surface Ships NSC Class Technical Specification Section 664, Damage Control Spaces NSC Technical Specifications, Sections 095-192 and 192 NSTM Chapter 074, Vol 1 and Vol 3, Welding and Allied Processes National Fire Protection Association NFPA 51 Standard for the Design and Installation of Oxygen-
Fuel Gas Systems for Welding, Cutting, And Allied Processes National Security Cutter Asset Operations and Maintenance (O&M) Technical Manual- Volume II.
Naval Ships’ Technical Manual (NSTM), Chapter 635, Thermal, Fire and Acoustic Insulation Naval Ships’ Technical Manual Chapter 074 Volume 3; Gas Free Engineering Naval Ships’ Technical Manual Chapter 631; Volumes 1 & 2; Preservation of Ships in Service Naval Ships’ Technical Manual, Chapter 074, Volume 1, Chg 5, Welding and Allied Processes Rev 4, 8/1/1999 Naval Ships’ Technical Manual, Chapter 074, Volume 3, Gas Free Engineering (Apr 98) Naval Ships’ Technical Manual, Chapter 505, Piping Systems, 12/1/2001 Naval Ships’ Technical Manual, Chapter 635, Thermal, Fire and Acoustic Insulation Naval Ships’ Technical Manual. Chapter 631 (V1-3).3B, Nondestructive Testing Handbook, American Society for Non-Destructive Testing, Volume 1, Section
SP-119, Factory-Made Wrought Belled End Socket Welding Fittings, 1/1/2003 TT-C-492C, Coating Compound, Paint Anti-Sweat TT-P-645B, Primer, Paint, Zinc-Molybdate, Alkyd Type Technical Manual, 1 ½” Thru 10” Gate Valves, Pima Valve Inc.
The Society for Protective Coatings (SSPC), Surface Preparation Specification No.11 (SSPC-SP 11), 01 Sep 2000, Power Tool Cleaning to Bare Metal xiii http://store.ihs.com/specsstore/controller?event=LINK_DOCDETAILS&mid=W097&getCurVer=false&docId=NCTWCBAAAAAAAAAA http://store.ihs.com/specsstore/controller?event=LINK_DOCDETAILS&mid=W097&getCurVer=false&docId=NCTWCBAAAAAAAAAA http://www.nfpa.org/aboutthecodes/AboutTheCodes.asp?DocNum=51&cookie%5Ftest=1 http://www.nfpa.org/aboutthecodes/AboutTheCodes.asp?DocNum=51&cookie%5Ftest=1 http://www.asnt.org/publications/handbook/handbook.htm http://www.asnt.org/publications/handbook/handbook.htm
The Society for Protective Coatings (SSPC)-SP 3, 11-1-1982, Power Tool Cleaning, 9/1/2000 The Society for Protective Coatings SSPC-SP 11, Rev -, 11/1/2004; Power Tool Cleaning to Bare
Metal The Society for Protective Coatings SSPC-SP 15, 11/1/2004; Commercial Grade Power Tool Cleaning Title 11, Hawaii Administrative Code Title 18, Alaska Administrative Code U.S. Coast Guard TP 7003–Technical Manual for Boat Davit Model DC-8600CTS US Code of Federal Regulations, 29 CFR Part 1915.73 Underwriters Laboratories Inc. (UL) 489, Edition 10; Molded Case Circuit Breaker WMSL 750 HVAC System Manual xiv http://www.sspc.org/standards/scopes.html http://www.hawaii.gov/health/about/rules/admrules.html http://touchngo.com/lglcntr/akstats/AAC/Title18.htm http://www.techstreet.com/cgi-bin/detail?product_id=1173948
CONSOLIDATED LIST OF GOVERNMENT FURNISHED PROPERTY
Description Manufacturer Part Number NIIN Qty UOI
ITEM 3: AFT DAMAGE CONTROL REPAIR LOCKER ESCAPE SCUTTLE
Scuttle: flush deck 21 inch clear open, all steel, watertight, quick acting scuttle, with three (3) quick acting dog arms, hand wheel on the inside and outside of the cover. Complies with
BUSHIPS 803-2226372.
Juniper Industries JE7055-SF-21 01 ea
Ladder, vertical, steel ACL Industries, Inc S-100 01 ea
ITEM 4: FORWARD DAMAGE CONTROL REPAIR LOCKER ESCAPE SCUTTLE
Scuttle: 21 inch clear open, all steel, watertight, quick acting scuttle, with three (3) quick acting dog arms, with ½ inch by 6 inch tall steel coaming, hand wheel on the inside and outside of the cover. Complies with
BUSHIPS 803-2226372.
Juniper Industries JE7943-SR-21-H 01 ea
Ladder, vertical, steel ACL Industries, Inc S-100 01 ea
ITEM 7: MULTI-CABLE TRANSIT INSTALL AND CABLEWAY SUPPORT
MCT Frame with 60 mm radius corners (MPC Annex-SCIF)
Roxtec Inc. CAGE Code 1B3L6
SRC 8x1 r60 primed, 6 inch band
1 ea
MCT Frame with 60 mm radius corners (MPC – MPC Annex)
Roxtec Inc. CAGE Code 1B3L6
SRC 8x3 r60 primed, 4 inch band
1 ea
MCT Frame with 60 mm radius corners (LAN – HF Transmitter)
Roxtec Inc. CAGE Code 1B3L6
SRC 8x2 r60 primed 1 ea
MCT Frame with 60 mm radius corners (HF Transmitter – Pway)
Roxtec Inc. CAGE Code 1B3L6
SRC 8x1 r60 primed 1 ea
MCT solid corner compensation module kit
Roxtec Inc. CAGE Code 1B3L6 RM 60/0 RC 4 ea
ITEM 8: FUEL VALVE MOTOR ACTUATOR AND CONTROLS INSTALL
Actuator for Mccanna 8” Full Port Ball Valve Flowserve-Limitorque QX-4 1 EA
ITEM 9: OVERHEAD LIGHTING FIXTURE MODS
Red Filter Tube (20w T12) L.C. Doane Company B-1634-S 00-295-2838 5 ea DPDT symbol 780.7 COMSACO, Inc Symbol 780.7 3 ea DPDT symbol 780.7-R COMSACO, Inc Symbol 780.7-R 1 ea DPDT symbol 780.7-S COMSACO, Inc Symbol 780.7-S 1 DPDT symbol 780.4 Pauluhn 862BHD20P 1 ea
Fluorescent Deck Fixture Pauluhn FPS320EMRV- 2CAI 15 ea
Fluorescent Deck Fixture Pauluhn FPS320EM- 2CAI 1 ea xv
Fluorescent Deck Fixture Pauluhn FPS120EM- 2CAI 2 ea
ITEM 10: TOILET/SHOWER AND STATEROOM COMPARTMENT STEP LIGHT ADDITIONS
Step Light Pauluhn F820ASSRV-
9PL 01-558-5836 61 ea
DPDT Center-Off Switch COMSACO, Inc Symbol 780.7 59 ea Junction Box, 4” square, stud mounted, 12 knockouts U.S. Pioneer 10000-212205 39 ea
Junction Box, 5” square, stud mounted, 12 knockouts RT&D BX552CPS 6 ea
ITEM 13: MPC ANNEX VENTILATION DUCT AND ELECTRICAL MODS
Overhead Fluorescent Light Fixture – (3-20W-T12) Surface mounted, W/ Hi-Impact acrylic clear prismatic diffuser, suitable for through feed w/ ¾” metal WT connections.
Pauluhn Electric, CAGE code 95405 FPS320-2CAI 1 ea
ITEM 15: FUEL OIL TRANSFER PIPING AND MANIFOLD MODIFICATION
Valve, 8” Full Port Ball Valve Mccanna
8”JFP1-S6-RF-
S6/PAA SS, Full port, $8250.00 Each 150# flanged end, Firesafe ball valve prepared For actuation(Valve Only)
N/A 1 EA
ITEM 16: AFFF TO CMWD CROSS CONNECT PIPING INSTALL
Valve, Gate, Flanged, ANSI B16.24, 3” IPS, 150 PSI, (per drawing 999- 79), with MX-05 Electric Operator (per drawing 130-12000)
PIMA 1619 4810-DAO-
740961 1 ea
ITEM 20: FORWARD ASIST STOPS INSTALL
Shock Absorber Assembly INDAL 8401-020-1 NA 4 Ea
ITEM 21: MPC LIGHTING MODS
Overhead Fluorescent Light Fixture – (3-20W-T12) Surface mounted, W/ Hi-Impact acrylic clear prismatic diffuser, suitable for through feed w/ ¾” metal WT connections.
Pauluhn Electric, CAGE code 95405 FPS320-2CAI 1 ea
ITEM 25: MISSION MODULE TO STATEROOM CONVERSION
Table, with drawer. 32”L x 21” W x 30”H. SFC No. B-4D-4 Drawing No. S3306-638434
Turnbull Enterprises 1 ea
Chair, Type 1, Style 1, Class B SFC No. B-3B-3 00-291-0332 1 ea xvi
Stateroom Overhead Lights Pauluhn FPS320-2CAI 2 ea Stateroom Overhead Light with single red filter tube Pauluhn FPS320RV-
2CAI 1 ea
1-MC speaker Dynalec 61720-350-01 01-345-6248 1 ea Heater, duct type, electric, 1.93KW, 450V, 3 phase INDEECO 210-154975 1 ea
Joiner Door to Stateroom, 26” x 74” clear opening, Type 1 with a 1- 3/8 inch sill and a continuous Roton hinge. Door is Aluminum Honeycomb panel construction with AL extruded frame. Baked enamel finish Type III, Class 2, of MIL-E-15090, color Brown FED STD 595 No. 20227.
Left Hand. Mortise Style cylinder Lock spec ANS/BHMA A156.2 Type 161 T-4, 14” x 14-1/4” Louver mounted 10 inches up from bottom of door, Door fitted with hook and other devices to hold door fully open.
Doors shall be fitted with anti rattle bumpers.
Baker Sheet Metal Corp.
CAGE Code 3D527
805-4629248 1 ea
ITEM 27: HF TRANSMITTER MECHANICAL & ELECTRICAL OUTFIT INSTALL
HVAC Controller (FVNR 0 LVR) PEPCO ASY02697 1 ea Air Conditioning Fan Coil Assembly FCA24 Type III (Left Hand unit)
Marlo Coil, CAGE code 38450 1484D0000 1 ea
Overhead Fluorescent Light Fixture – (2-20W-T12) Surface mounted, W/ Hi-Impact acrylic clear prismatic diffuser.
Pauluhn Electric, CAGE code 95405 FPS220-2CAI 2 ea
Overhead Fluorescent Light Fixture – (2-20W-T12) Surface mounted, W/ Hi-Impact acrylic clear prismatic diffuser, battery powered emergency ballast.
Pauluhn Electric, CAGE code 95405
FPS220EM-
2CAI 1 ea
1” Solenoid Valve (NO), 120 Volt, brass body and SB union ends ASCO Valve AV198970004 1 ea
1” Solenoid Valve (NC), 120 Volt, brass body and SB union ends ASCO Valve AV174360010 1 ea xvii
GENERAL REQUIREMENTS — DOCKSIDE, HOME PORT
GR_00000_JMS_0308_Fleet
1 INTENT
This document invokes general requirements applicable to ship repair contracts for work performed at a cutter’s home port pier.