Male Head Female Head
Locker Room
Conference Room
Three person office
Mechanical Room
CPO Office
Waiting Area
LHO Office
Kitchen Area
Carpentry Shop
C o r r i d o r
Electrical shop
Storage Area
Desk
Desk
Desk Desk
Desk
Desk
FILES
Entrance Shop Entrance
Deep Sink
Bench Bench
Secure Storage
Storage Entrance
Doors
Comp Room
Toilets
50’
100’
40’ 16’ 12’ 10’ 10’ 14’
42’
1” = 8’
Chair
Desk
Sink
Locker
Shower Shower
Computer
TV
Storage shelves
Windows
Carpentry 4 Male Heads 1 Female Head 1 Conference 3 LHO Office 1 Waiting area 1 Three person 4 Electrical 1
No Windows in storage area
Storage shelves
4’
Room sizes are approximate, scale rooms based on dimensions shown, increase as neccessary to provide a complete and functional facility
105A
MMcAll Text Box Shop entrance door and storage entrance door shall be min 10'-0" roll-up doors lockable from the inside and both motor and chain operated.
All other man doors shown will have door closers and kick plates on both sides.
MMcAll Text Box Doors
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Text Box Provide additional doors on exterior as needed for exiting requirements
MMcAll Text Box In addition to the outlets required in the RFP provide 8 recessed flush mounted duplex 20 amp 120 v floor outlets with covers in the carpentry shop area. Recessed outlet boxes must be traffic rated. Floor out lets must be on 4 separate circuits and disconnect with the 1 power off button for all outlets within this space.
MMcAll Text Box Provide 230v 60 amp breaker and outlet for welder and provide exhaust system.
MMcAll Line
MMcAll Text Box Double door
MMcAll Line
MMcAll Text Box provide a minimum of 1 exterior hydrant centered on each face of the building.
MMcAll Text Box provide expanded metal lockable cage full hieght wall and door
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Text Box
REVISED MAINTENANCE FLOOR PLAN DATED 3-21-16
MMcAll Text Box Provide flush mounted 2 duplex 20am 120 volt floor boxes in center of the Conference room in addition to other outlet requirements.
MMcAll Text Box Furnish and install overhead air distribution system and 2 retractable air hose systems with 50" of hose on each. Space reels 20 feet apart from the center of Carpenter shop. Provide piping to each of the compressed air points of connections shown.
MMcAll Oval
MMcAll Oval
MMcAll Oval
MMcAll Oval
MMcAll Oval
MMcAll Oval
MMcAll Oval
MMcAll Oval
MMcAll Text Box Compressed air point of connection
MMcAll Text Box
MMcAll Text Box
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Line
MMcAll Text Box Provide new two lane ac paved road to new maintenance building. Install road and provide lighting curbs gutters and sidewalks as required to meet State DOT and City of Astoria standards. Provide and stripping, wheel stops and parking spaces for 10 vehicles (9' x18' spaces min). Delivery truck can be assumed to back in for large loads. Provide K rail barrier at edge of road and parking area where necessary to keep vehicles from leaving paved area.
Insure access to existing office and garages remains usable during and after completion of new facility.
locate maintenance building in general area shown .adjust grades as necessary to provide parking and roads. demolish existing playground shown under new maintenance facility entirely. Provide bollards by all roll-up doors Provide a dumpster pad at least 8'x 12' Coordinate and pay for any utility connections directly with the utility provider and or City of Astoria.
MMcAll Text Box
REVISE MAINTENANCE BUILDING CONCEPT
SITE PLAN. Dated 3-21-16
Space Criteria Analysis Data Sheet
GREATER ASTORIA FAMILY HOUSING PHASE II / SECTOR COLUMBIA
RIVER
Housing Maintenance Shop/Storage Space Project SFRL 13-S04004
Sector Columbia River Family Housing
Minimum Housing Maintenance Building Space Requirements
SPACE NAME
SIZE
SPACE CODE
ENGLISH (sf)
Column1 Column2 Column3
CARPENTRY SHOP
Shop Assembly Area 100 219.002
Shop Equipment 219.003
Drill press 140 219.007
Table saw 265 219.017
Tool storage (10sf per DC/carpenter assigned) 50 219.018
Vertical saw (Panel Saw) 120 219.019
Work bench
(60sf per every two DC's/carpenters assigned) 120
CARPENTRY SHOP STORAGE 219.400
Secured Shop Storage (Table A sf) 150 219.401
Wood Storage Table (Table B sf) 400 219.402
Materials Storage (Table C sf) 300 219.403
219.030
219.430
219.031
219.431
ELECTRICAL MAINTENANCE 219.060
ELECTRICAL SHOP 219.061
Shop Circulation 150 219.062
Shop Equipment 219.063
Threader 60 219.066
(size per every two EM's/electricians assigned) 60 219.067
ELECTRICAL SHOP STORAGE 219.46
Secured Shop Storage (Table D sf) 120 219.461 Secured Materials/Lamp Storage (Table E sf) 100 219.462
GREATER ASTORIA FAMILY HOUSING PHASE II / SECTOR COLUMBIA
RIVER
Housing Maintenance Shop/Storage Space
SECURE STORAGE 219.080
Storage 120 219.081
219.480
ADMINISTRATIVE SPACES
Shared Office
DCC/E7 & DC1/E6 Office 150 Open Office Area (60sf per Workstation)
Work stations (1:3 Workstation to Mx Staff) 120 Shipping and receiving 200
Male/Female locker/toilet/showerss 300 Break Room/Coffee Mess 100
Conference room 250
Total min Net Square Feet Per Drawing
Mimimum TOTAL GROSS SQUARE FEET 5,000
Note: Maintenance building shall comply with ADA requirements increase spaces as required to provide accessable spaces.
GREATER ASTORIA FAMILY HOUSING PHASE II / SECTOR COLUMBIA RIVER
Housing Maintenance Shop/Storage Space Project SFRL 13-S04004
Room Number and Space Name: BUILDING SUPPORT SPACES, AS NEEDED: JANITOR’S
CLOSET, MECH / ELEC / COMM ROOMS
1. Space function / user activity:
Provide support spaces as needed. Provide a janitor’s closet for equipment, tools, and supplies
2. Number of occupants:
Not Applicable
3. Contractor Furnished and Contractor Installed (CFCI) Specialties, Equipment and Furnishings:
SU – Shelving Units – provide two (2) 18” deep,48” wide, and 87” high metal shelving units in Janitor’s closet
4. Government Furnished and Contractor Installed (GFCI) Specialties, Equipment and Furnishings:
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable) – requiring CFCI utility connections:
None
6. Finishes (function, durability and maintenance issues):
Floor: Sealed concrete Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent grade Walls in Janitor’s closet: Provide Fiberglass Reinforced Panels (FRP) over gypsum board Ceiling: Suspended acoustical ceiling tile system; minimum 9’ height or painted gypsum board.
Telecommunications closet: shall be a minimum of 100 sf, One wall will have a minimum of 32 sf 5/8” fire treated plywood painted white for telecommunications punch downs. Ceiling shall be sheetrock with surface mounted lighting in this space.
7. Doors: (note: verify any fire rating requirements):
Fire rating as required,
8. Windows:
None
9. Room Identification Signage: (install at latch side of door)
PER ADA requirements
10. Sound Attenuation Treatment including STC Rating requirements:
None
Housing Maintenance Shop/Storage Space Project SFRL 13-S04004
Room Number and Space Name: BUILDING SUPPORT SPACES, AS NEEDED: JANITOR’S
CLOSET, MECH / ELEC / COMM ROOMS
11. Physical Security (Classification, IDS, CCTV, etc):
Provide “Best” 7 pin, removable core, keyed locks on Communications room, Mechanical and electrical rooms. Provide passage set for janitor closet.
12. Mechanical (HVAC):
Standard ventilation, heating and cooling system per Section 01800-1.12.
13. Plumbing:
Plumbing for fixtures per Section 01800-1.11 Water Janitor’s mop sink
14. Electrical (power/lighting):
Provide lighting fixtures compatible with ceiling tile system per Specification Section 01800- 1.13.
Provide Receptacle Outlets per Specification Section 01800-1.13.
15. Communications:
Provide 1 tel/data outlet per Section 01800-1.14 (3 CAT 5 outlets).
16. Other:
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 101 - CARPENTRY SHOP
This space is used to repair, re-build or assemble miscellaneous general carpentry items for the housing units.
2. Number of occupants:
Normal Hours – 40-50 per week Maximum - Up to 10 personnel
3. Contractor Furnished and Contractor Installed (CFCI) Specialties, Equipment and
WH - Whiteboard, provide two (1) 4’ tall by 4’ wide porcelain steel surface with aluminum trim.
CB – Cork Board, provide one (1) 4’ tall by 4’ wide cork board with aluminum trim.
CH - Steel coat hooks. Provide four (4) grouped together and located at entry door.
FE - Fire Extinguisher, provide one (1) 15lb cabinet mounted WBL –Window Blinds, 1” horizontal, aluminum, provide one (1) at each window DUST COLLECTION SYSTEM - Per Section 01800-1.12.
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable) – requiring CFCI utility connections:
Table saw Drill Press Vertical Saw Work Benches (2) Tool Storage Shelving (3) Computers (2) Phones (2) Self contained Eyewash (1)
6. Finishes (function, durability and maintenance issues):
Floor: Sealed concrete, with non-slip/non-skid finish Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent grade Ceiling: Suspended acoustical ceiling tile system; minimum 12’ height
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 101 - CARPENTRY SHOP
Opening from Interior - Provide 3’ wide by 7’ tall wood door on steel frames and lockable lever handle. Provide “Best” 7 pin, removable core, keyed locks on all doors securing perimeter of Carpentry shop including interior doors.
8. Windows:
Vinyl, Double hung, with insulating glass ( provide 4 windows – min( 3’x 5’)) Provide solid surface sills, insect screens, and 1” horizontal blinds.
9. Room Identification Signage: (install at latch side of door)
PER ADA Requirements
10. Sound Attenuation Treatment including STC rating requirements:
Provide min 50 STC separation between Carpentry shop and office and conference spaces
11. Physical Security (Classification, IDS, CCTV, etc):
None
12. Mechanical (HVAC):
Standard heating and cooling system per Section 01800-1.12.
13. Plumbing:
None
14. Electrical (power/lighting):
Provide Lay-in Lighting fixtures compatible with ceiling tile system per Specification Section 01800-1.13.
Provide Receptacle Outlets per Specification Section 01800-1.13.
15. Communications:
Provide 2 tel/data outlets, at work bench area and 1 tel/data outlet every 20 feet along shop walls, per Section 01800-1.14 .
Keying – Provide Best brand locks with 7 pin removable cores to match existing at Coast Guard main office
Provide a shop area as shown on revised maintenance building floor plan dated 3-21-16.
Provide power kill buttons at all man doors entering the carpentry shop. This Power kill buttons shall disable all shop equipment and outlets within this carpentry shop space lights shall stay on. Provide protective cover and signage for all power “kill” buttons.
Provide Compressed air piping and outlets where shown on floor plan dated 3-21-16.
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 102 - CARPENTRY SHOP STORAGE
This space is used for bulk storage of miscellaneous general carpentry items, supporting the
Carpentry Shop. This space also supports shipping and receiving.
2. Number of occupants:
Storage System capable of 100lbs/sf of storage 3 shelves 12’ high 36” wide along walls and center of storage area as indicated on drawings
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable) – requiring CFCI utility connections:
Bulk material storage cabinets, bins, boxes, etc.
6. Finishes (function, durability and maintenance issues):
Floor: Sealed concrete, with non-slip/non-skid finish Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent
Ceiling: Suspended acoustical ceiling tile system; minimum 12’ height
Opening to Exterior, Provide 12’-0” wide by 10’-0” high insulated Overhead Sectional Door, lockable, automatic sectional door.
Opening from Interior – Provide 2- 3’ wide by 7’ tall wood doors on steel frames and lockable lever handle and 3’-0 high Kick plates both sides of doors.
8. Windows:
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 102 - CARPENTRY SHOP STORAGE
Per ADA requirements
10. Sound Attenuation Treatment including STC rating requirements:
11. Physical Security (Classification, IDS, CCTV, etc):
None
12. Mechanical (HVAC):
Standard heating system per Section 01800-1.12.
13. Plumbing:
Provide one exterior hose bib near the exterior doors
14. Electrical (power/lighting):
Provide Lay-in Lighting fixtures compatible with ceiling tile system per Specification Section 01800-1.13.
Provide Receptacle Outlets per Specification Section 01800-1.13.
15. Communications:
Provide 1 tel/data outlet, per Section 01800-1.14.
Keying – Provide Best brand locks, 5 button security rated lockset with removable 7 pin core.
Provide a minimum space required to make the storage area functional per the layout shown. Passage ways between storage shall be 4’-0” wide minimum.
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 103 – SECURESTORAGE STORAGE
This space is used as Secure storage space for higher value items
Maximum - Up to 3 personnel
WBL – Shelving provide shelving all 4 walls 5 shelves per wall, capacity 50 1bs/foot
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable – requiring CFCI utility connections:
Bulk material storage cabinets, bins, boxes, shelves, etc.
Base: Resilient rubber Walls: Painted gypsum board over 5/8” T&G Plywood on metal or wood studs (over concrete where walls abut adjacent grade Ceiling: Painted gypsum board over 5/8” T&G Plywood 9’ height min.
Opening from Interior - Provide 3’ wide by 7’ tall metal door on steel frames. Provide security rated 5 button combination lock and removable 7 pin core compatible with Best Access system.
none
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 103 – SECURESTORAGE STORAGE
12. Mechanical (HVAC):
Standard heating and cooling system per Section 01800-1.12.
13. Plumbing:
None
14. Electrical (power/lighting):
Provide lighting fixtures compatible with ceiling system per Specification Section 01800-1.13.
16. Other:
Keying – Provide Best brand locks
Size room per maintenance building layout dated 3-21-16 min 150 square feet.
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 104 – Conference Room
This space is used as conference and training room
Built in wall mounted desk/counter, min 28” wide solid surface material for training up to 4 people as shown.
WBL – Window Blinds, 1” horizontal, aluminum, provide one (1) at each window
4. Government Furnished and Contractor Installed (GFCI) Specialties, Equipment and Furnishings:
Conference table, wall mount TV
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable –
Bulk material storage cabinets, bins, boxes, shelves, etc. wall mounted TV
Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent
Ceiling: Suspended acoustical ceiling tile system; minimum 9’ height handle
Vinyl, Double Hung, with insulating glass ( min 2- 3’ X 5’ windows)
10. Sound Attenuation Treatment including STC Rating requirements:
50 STC all walls and ceiling
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 104 – Conference Room
12. Mechanical (HVAC):
Standard heating and cooling system per Section 01800-1.12.
13. Plumbing:
None
14. Electrical (power/lighting):
Provide Lay-in Lighting fixtures compatible with ceiling tile system per Specification Section 01800-1.13.
Provide duplex receptacle at each training area, Provide recessed quad outlet under conference room table (collocate with tele/data), Provide recessed wall outlet for TV. Receptacle Outlets per Specification Section 01800-1.13.
Provide (1) cable television outlet, per Section 01800-1.15 for TV 6’ above Finished floor.
15. Communications:
Provide 1 duplex tel/data outlet, per work station and every 6’ along walls. Provide recessed floor mounted quad tele data under conference room table. per Section 01800-1.14.
Keying – Provide lockable Handset with removable 7 pin core.
Provide a minimum of 250 net square feet
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 105 – ELECTRICAL MAINTENANCE
This space is used as an Electrical maintenance shop to support residential electrical equipment, fixtures, outlets, etc.
2. Number of occupants:
WBL – Window Blinds, 1” horizontal, aluminum, provide one (1) at each window (if windows are provided)
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable – requiring CFCI utility connections:
Threader
Floor: Sealed concrete, with non-slip/non-skid finish and static guard rubber flooring.
Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent grade Ceiling: Suspended acoustical ceiling tile system; minimum 9’ height or painted gypsum board.
Opening from Interior (2) 3’ wide by 7’ tall wood door on steel frames and lockable lever handle
8. Windows :
Vinyl, Double Hung, with insulating glass (Min 1 window 3’ x 5’)
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 105 – ELECTRICAL MAINTENANCE
12. Mechanical (HVAC):
Standard heating system per Section 01800-1.12.
13. Plumbing:
None
14. Electrical (power/lighting):
Provide 1 tel/data outlet, 1 per workstation, per Section 01800-1.14.
Keying – Provide Best brand locks to match existing at Coast Guard main office
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 105A – ELECTRICAL SHOP STORAGE
This space is used as secured storage in support of the Electrical maintenance shop.
None
4. Government Furnished and Contractor Installed (GFCI) Specialties, Equipment and Furnishings:
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable) – requiring CFCI utility connections:
Shelving and Storage cabinets
6. Finishes (function, durability and maintenance issues):
Floor: Sealed concrete, with non-slip/non-skid finish and static guard rubber flooring.
Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent grade 7 Gauge Expanded metal cage wall with sliding door full height Ceiling: Suspended acoustical ceiling tile system; minimum 9’ height or painted gypsum
Expanded metal Sliding door with removable 7 pin Core and handle.
9. Room Identification Signage: (install at latch side of door)
PER ADA Requirements
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 105A – ELECTRICAL SHOP STORAGE
Standard heating system per Section 01800-1.12.
13. Plumbing:
None
14. Electrical (power/lighting):
Keying – Provide Best brand locks with 7 pin removable core
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 106 – SHARED OFFICE
This space is used as a general office / work station area.
Maximum - Up to 5 personnel
WH - Whiteboard, provide one (1) 4’ tall by 4’ wide porcelain steel surface with aluminum trim.
WBL –Window Blinds, 1” horizontal, aluminum, provide one (1) at each window
4. Government Furnished and Contractor Installed (GFCI) Specialties, Equipment and Furnishings:
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable – requiring CFCI utility connections:
OSF - Office Systems Furniture, provide two (2) panel hung cubicle workstations.
DC – Desk chair, provide two (2) LF – Lateral file cabinet, provide two (2) 36” wide, 28” high, 18” deep, steel cabinet BK – Book shelf, provide one (1) FC – File cabinet, provide two (2) WH - Whiteboard, provide two (2) 4’ tall by 4’ wide porcelain steel surface with aluminum trim.
Computers (3) Phones (4)
Floor: Linoleum Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent grade Ceiling: Suspended acoustical ceiling tile system; minimum 9’ height or painted gypsum
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 106 – SHARED OFFICE handle
8. Windows:
Vinyl, Double Hung, with insulating glass (min 4- 3’ x 5’)
10. Sound Attenuation Treatment including STC Rating requirements:
None
11. Physical Security (Classification, IDS, CCTV, etc):
None
12. Mechanical (HVAC):
Standard heating and cooling system per Section 01800-1.12.
13. Plumbing:
None
14. Electrical (power/lighting):
Provide 1 tel/data outlet per workstation, per Section 01800-1.14.
16. Other:
Keying – Provide Best brand locks with 7 pin removable cores.
Provide a minimum of 150 net square feet
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 107 – LHO OFFICE COUNSELING AREA
This space is used as a housing manager office and tenant counseling.
Maximum - Up to 4 personnel
WH - Whiteboard, provide two (2) 4’ tall by 4’ wide porcelain steel surface with aluminum trim.
WBL –Window Blinds, 1” horizontal, aluminum, provide one (1) at each window
4. Government Furnished and Contractor Installed (GFCI) Specialties, Equipment and Furnishings:
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable – requiring CFCI utility connections:
OSF - Office Systems Furniture, provide two (2) panel hung cubicle workstations.
DC – Desk chair, provide two (2) LF – Lateral file cabinet, provide two (2) 36” wide, 28” high, 18” deep, steel cabinet BK – Book shelf, provide one (1) FC – File cabinet, provide two (2) Computers (1) Phones (1)
Floor: Linoleum Base: Resilient rubber Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent grade Ceiling: Suspended acoustical ceiling tile system; minimum 9’ height or painted gypsum board.
7. Doors: (note: verify any fire rating requirements):
handle.
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 107 – LHO OFFICE COUNSELING AREA
Vinyl, Double Hung, with insulating glass (Min 2- 3’x5’)
Per ADA Requirements
10. Sound Attenuation Treatment including STC Rating requirements:
50 STC walls and ceiling
11. Physical Security (Classification, IDS, CCTV, etc):
None
12. Mechanical (HVAC):
Standard heating and cooling system per Section 01800-1.12.
13. Plumbing:
None
14. Electrical (power/lighting):
Provide 1 quad tel/data outlet per workstation, per Section 01800-1.14.
16. Other:
Keying – Provide Best brand lockswith removable 7 pin core.
Provide a minimum of 150 net square feet
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 108 & 109 – MEN & WOMEN’S ROOM
This space provides toilet facilities for personnel.
N/A
3. Contractor Furnished and Contractor Installed (CFCI) Specialties, Equipment and Furnishings:
CH – Coat Hooks, provide four (4) per toilet room PAR – Partitions, at toilet stalls and urinals, HDPE construction MIR – Mirror, 36” high, full length of counter top, provide one (1) per toilet room PTD – Paper Towel Dispenser/Trash Receptacle, provide one (1) per toilet room SOD – Soap Dispenser, provide one (1) per sink TTD – Toilet Tissue Dispenser, double roll, provide one (1) per toilet stall SCD – Seat Cover Dispenser, provide one (1) per toilet stall FHD – Feminine Hygiene Disposal, provide one (1) per toilet stall. In Women’s
Toilet room only HDR – Hand Dryer, provide one (1) per toilet room (Electric Air dryer) WBL –Window Blinds, 1” horizontal, aluminum, provide one (1) at each window (if provided).
Shower Curtain/ shower stall
None
5. Government Furnished and Government Installed (GFGI) Equipment (fixed and movable) – requiring CFCI utility connections:
None
6. Finishes (function, durability and maintenance issues):
Floor: Ceramic tile Base: Ceramic tile cove base Walls: Painted moisture-resistant gypsum board over metal or wood studs (over concrete where walls abut adjacent grade), ceramic tile wainscot up to 4’-0” above finish floor Ceiling: Suspended acoustical ceiling tile system; minimum 9’ height or painted gypsum
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 111 CPO OFFICE
Opening from Interior - Provide 3’ wide by 7’ tall wood door on steel frames and push/pull hardware. Doors shall not be lockable.
8. Windows :
Vinyl, Casement , with insulating opaque glass
Per ADA Requirement
10. Sound Attenuation Treatment including STC Rating requirements:
Provide sound attenuation batt insulation in all surrounding stud wall cavities (STC 45 min). Provide sound attenuation batt insulation above ceiling tile.
12. Mechanical (HVAC):
Standard ventilation, heating and cooling system per Section 01800-1.12.
13. Plumbing:
Plumbing for fixtures per Section 01800-1.11 Water efficient lavatories, for all lavatories shown Water efficient urinal, provide per drawing of Men’s Toilet room
Provide a minimum of 120 net square feet each.
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 110 KITCHEN AREA
This space provides a break room / small conference area / all purpose space for personnel.
Maximum - Up to 4 personnel
RF – 25.0 cu ft Refrigerator Energy Star rated with ICE maker MW - 2.0 cubic foot countertop microwave oven, on shelf above countertop SSC - Solid Surface Countertop with backsplash.
CAB – Cabinets, under countertop and above counter continuous include shelf above for microwave
4. Government Furnished and Contractor Installed (GFCI) Specialties, Equipment and Furnishings:
None
5. ContractorFurnished and Contractor Installed (GFC) Equipment (fixed and movable) –
Floor: Vinyl tile Base: cove base Walls: Painted gypsum board over metal or wood studs (over concrete where walls abut adjacent grade), None.
9. Room Identification Signage: (install at latch side of door)
Per ADA Requirement
10. Sound Attenuation Treatment including STC Rating requirements:
None
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 110 KITCHEN AREA
Standard ventilation, heating and cooling system per Section 01800-1.12.
13. Plumbing:
Plumbing for fixtures per Section 01800-1.11 Water efficient kitchen sink Water supply with valves for Coffee maker separate from sink
Provide Receptacle Outlets per Specification Section 01800-1.13. Minimum of 4 duplex outlets above counter.
15. Communications:
None
16. Other:
Layout per drawing t.
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 112 LOCKER ROOM
This space provides a personnel clothing storage for staff
2. Number of occupants:
Maximum - Up to 12 personnel
Provide 12 24” X 18” X 6’ Metal lockers with lockable doors Lockers must be set on 4” high Concrete curb.e
None
5. ContractorFurnished and Contractor Installed (GFC) Equipment (fixed and movable) –
Base: cove base
None.
9. Room Identification Signage: (install at latch side of door)
Per ADA Requirement
10. Sound Attenuation Treatment including STC Rating requirements:
Standard ventilation, heating and cooling system per Section 01800-1.12.
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 112 LOCKER ROOM
13. Plumbing:
Plumbing for fixtures per Section 01800-1.11 Water efficient kitchen sink Separate Water supplies with valves for coffee maker separate from sink, and for Ice maker
14. Electrical (power/lighting):
Provide lighting fixtures compatible with ceiling system per Specification Section 01800-1.13.
Provide Receptacle Outlets per Specification Section 01800-1.13. Minimum of 4 duplex outlets above counter.
Layout per drawing
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 113 WAITING ROOM
This space provides a waiting area for tennats
2. Number of occupants:
Maximum - Up to 8 personnel
NONE
4. Government Furnished and Contractor Installed (GFCI) Specialties, Equipment and Furnishings:
None
5. ContractorFurnished and Contractor Installed (GFC) Equipment (fixed and movable) –
NONE
Base: cove base
Front door shall be fiberglass with 12”x 18” window light and have lockable Best hardware with removable 7 pin cores.
8. Windows:
Provide 1 vinyl window 3’x 5’ double hung with solid surface sill.
9. Room Identification Signage: (install at latch side of door)
Per ADA Requirement
10. Sound Attenuation Treatment including STC Rating requirements:
None
11. Physical Security (Classification, IDS, CCTV, etc):
None
12. Mechanical (HVAC):
Standard ventilation, heating and cooling system per Section 01800-1.12.
13. Plumbing:
Housing Maintenance Shop/Storage Space
Room Number and Space Name: RM 113 WAITING ROOM
Provide Receptacle Outlets per Specification Section 01800-1.13. Minimum of 2 duplex outlets
15. Communications:
Provide 1 data and telephone Jack
16. Other:
Provide Layout per drawing.
Provide walk off mat at entry
Housing Maintenance Shop/Storage Space
Room Number and Space Name: CORRIDOR
Room Number and Space Name: RM 114 Corridors
1. Walls Painted sheet rock
2. Provide stainless steel Corner Guards on all outside corners minimum 4’ high.
3. Provide lighting fixtures compatible with ceiling system per Specification Section 01800-1.13 Provide duplex outlet every 20 linear feet along corridor.
End of Section.
| Maintenance building ammendment 5 |
| Slide Number 1 |
| Slide Number 2 |
Maint building Space Criteria