Attachment 8 - Questions and Answers - RFP AMD2.xlsx

XLSX spreadsheet 21 KB Posted

Attached to
Outside the Continental United States (OCONUS) Information Technology (IT) Solutions II
Solicitation number
HC102823R0032
Issued by

View the file

Other files

File Type Posted
HC102823R0032 AMD03.pdf PDF
Attachment 8 - Questions and Answers AMD03.xlsx XLSX spreadsheet
Attachment 3 - TO0001 PWS - RFP AMD2.docx DOCX document
HC102823R0032 AMD2.pdf PDF
Attachment 1 - PWS Acronym List RFP AMD2.xlsx XLSX spreadsheet
Attachment 5 DD254_Revised.pdf PDF
Attachment 6 SCI Addendum_Revised.pdf PDF
HC102823R0032 AMD0001.pdf PDF
Attachment 13 - Response to Draft RFP Questions.pdf PDF
Attachment 4 - TO0001 QASP.docx DOCX document
Attachment 7 - Non Disclosure Agreement.docx DOCX document
HC102823R0032.pdf PDF
Attachment 11 Req_for_Past_ and Present Performance_Info.docx DOCX document
Attachment 10 - CLIN Pricing Worksheet for TO 0001.xlsx XLSX spreadsheet
Attachment 3 - TO0001 PWS.docx DOCX document
Attachment 2 - Base QASP - IDIQ.docx DOCX document
Attachment 1 - PWS Acronym List.xlsx XLSX spreadsheet
Attachment 12 - Evaluation_Table_with_Past_Performance.docx DOCX document
Attachment 9 - Schedule of Rates IDIQ Contract.xlsx XLSX spreadsheet
Attachment 8 - Question and Answer Template.xlsx XLSX spreadsheet
Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Instructions

Q&A INSTRUCTIONS: The purpose of these specific instructions is to expedite the process of answering questions. Please do not change the format of this document.
Complete the spreadsheet tab below named "Q&A" with all questions, comments, and recommendations about the RFP. Examples provided in the spreadsheet. **Please delete the examples before submitting your questions.

COLUMN A: Complete the "Page" column. This is the page number from the RFP located in the upper right hand corner of the page. Do not include the total page number. Enter only the page number where the topic begins.

COLUMN B: Complete the "Section/Paragraph" column with the applicable section and paragraph number (if applicable) of the RFP. For example: B2, C, or L5.1.2. For a section and paragraph number reference do not place a dot between the letter and the first number. Additional subparagraph references should be separated with a dot regardless of the format in the RFP, for example, L5.1.2.a. Do not including any other extraneous identifiers or other information other then instructed here. If the reference is to a CLIN, Clause, Appendix, or Attachment etc. the entry goes in the next column. At a minimum you will always insert at least the Section letter A through J in this column.

COLUMN C: Complete the "CLIN/Clause/Other" column. Insert the CLIN, Clause, Provision, Appendix, or Attachment number. For example: CLIN 0001, 52.217-8, Appendix A, or Attachment L3. Insert the section letter only in the Column B. This column will be completed only when there is not a more precise RFP reference number. NOTES: CLINs are in Section B. Most sections contain clauses so ensure you reference the correct section.

COLUMN D: Complete the Questions/Comments/Recommendations column. Start the question by referencing the topic. This may help the sort process. For example: Minimum Qualifications Checklist or Performance Area 10. Then insert the question or comment.

Issues must be submitted to the Contracting Officer and Contract Specialist listed in L2.1.1.

Q&A

RFP PageRFP PageRFP Section/ ParagraphCLIN/ Clause/Appendix/Attachment/OtherQuestions/Comments/RecommendationsGovernment Response to Industry
122 of 177PWS 6.2.5 Installation Design Plan (IDP)HC102823R0032Can the government confirm order of precedent when there are conflicts between the SIPH Manual, Reference Standards, and the PWS?The Task Order (TO) Performance Work Statement (PWS) will take precedence.
228 of 177PWS 6.5.1 Procurement: Trade Agreements Act (TAA)HC102823R0032Is the Trade agreements act (TAA) clause incorporated into this contract? If not, we recommend that the requirement in 6.5.1 should be updated to reflect this, or recommend adding a section H provision that outlines specific requirements.The solicitation includes the following DFARS Provisions and Clauses: 252.225-7001, 252.225-7002, 252.225-7003, 252.225-7004, 252.225-7005.
328 of 177PWS 6.5.1 Procurement; Radio Frequency Identification (RFID)HC102823R0032Can the government confirm criteria or applicable items for equipment requiring RFID marking?Please refer to MIL-STD-129R.
429 of 177PWS 6.5.2.2.1: Specialized Secure ShipmentsHC102823R0032The last sentence of this section currently states: “Additionally, all IT hardware must be shipped overseas through the DIA DLOC.” For clarity, we recommend this be changed to: “Additionally, all IT hardware that will connect to a DIA network must be shipped overseas through the DIA DLOC.”PWS paragraph 6.5.2.2.1 has been updated.
5149 of 177ADDENDUM TO 52.212-1/ (iv) Page limitationsHC102823R0032Please confirm that 11x17 pages are acceptable to use for large graphics and charts.11x17 pages are only allowed for Sample IDPs. Section L has been updated.
6Page 170 of 177 &
Page 176 of 177Section L Table 1 Proposal Organization & Section M: Evaluation CriteriaHC102823R0032There is an inconsistency between Sections L and M regarding the page limit for each project reference. Please confirm the page limit for each Past Performance Reference is 5 pages.Past Performance References may be 5 pages. Section M has been updated.
7Page 170 of 177(B) Volume II – Technical/ManagementHC102823R0032Please confirm that font size of 8-point Arial, Times New Roman, or Courier New is acceptable for included tables across all Factors.The following applies to all documents: The page format shall have a 1-inch margin using no smaller than an 11-point Arial, Times New Roman, or Courier New font for all text to include any text contained in a table. Graphics shall have a text size with visual appearance equal to or greater than 8-point font.
8175 of 177HC102823R0032

Section M - Evaluation Factors for Award/Addendum to 52.212-2(a),

a. Basis for Contract Award Section 508 Accessibility Standards HC102823R0032

"Any proposal failing to meet the Section 508 Accessibility Standards, as listed in the Basic and Task Order 0001 PWSs, may be eliminated from consideration for award." Do the proposal documents themselves need to be compliant with Section 508 Accessibility Standards?No. Proposal documents in compliance with Section L instructions are sufficient.
9N/ATable 3. Past Performance Acceptable/Unacceptable Rating MethodAttachment 12The Past Performance evaluation criteria outline and the note referencing FAR 15.305[a][2][iv] in Attachment 12 does not allow the Government to consider the benefits and reduced risk provided by an offeror with a track record of relevant performance on other contracts. The current method rates an Offeror with directly relevant experience and an Offeror with no relevant performance the same. We recommend evaluating past performance using Past Performance Relevancy Ratings, Past Performance Quality Ratings, and Performance Confidence Assessments.At this time the Government does not intend to change the Past Performance evaluation criteria.
10169Section LTable 1 Volume IIWill the Government please explain the phrasing of 'Sample IDP or Migration/Cutover Plan,' The phrasing implies that one or the other is not required as part of our response. Do we need to include both a Sample IDP and a Migration/Cutover plan to be compliant with the requirement of the proposal?Sections L and M have been updated to require both a Sample IDP and a Sample Migration and Cutover Plan. The Sample IDP only may be provided on page size of 11x17. The Sample IDP and Sample Migration and Cutover Plan will not count against page limits. Evaluation Factor 1, Subfactor 1 has been updated.
11175Section M(a) Subfactor 1The government states, "The Systems Migration and Cutover Plan shall also be integrated into the IDP . . . " This contradicts Section L above. Sample IDP "or" Migration/Cutover Plan for TO 0001 is "OPTIONAL". Will the Government please confirm if the optional Systems Migration and Cutover Plan should be integrated into the optional sample IDP, or if these should be separate optional documents.Sections L and M have been updated to require both a Sample IDP and a Sample Migration and Cutover Plan. The Sample IDP only may be provided on page size of 11x17. The Sample IDP and Sample Migrationand Cutover Plan will not count against page limits. Evaluation Factor 1, Subfactor 1 has been updated.
12196.1.2POA&MThe TO PWS defines a POA&M as a Plan of Action and Milestones while the Basic PWS and Acronym List define it as Plan of Objectives and Milestones. Which is correct?Plan of Action and Milestones. Documents have been updated.
1353Section CLABOR CATEGORY DESCROPTIONSThe Engineer/Scientist 2 requires three (3) years of experience in IT but five (5) years of technical experience in support of development, testing, and implementation of Department of Defense requirements, programs and/or projects. The Engineer/Scientist 3 also requires five (5) years of technical experience in support of development, testing, and implementation of Department of Defense requirements, programs and/or projects. Will the Government please confirm that these 2 positions require the same amount of technical experience in support of development, testing, and implementation of Department of Defense requirements, programs and/or projects?

The Labor Category Descriptions in question are listed below for the Government' convenience:

Engineer/Scientist 2 Education: BS degree in Engineering, Computer Science, Information Systems, or related field. Experience: Three (3) years of experience in the area of information technology, to include: Technology Analysis and Assessment, Design Definition, Development of Systems Specification, Systems Analysis, Systems Architecture, Systems/Equipment Integration, Test & Evaluation Criteria, and Logistics support of C4ISR requirements. Five (5) years of technical experience in support of development, testing, and implementation of Department of Defense requirements, programs and/or projects. Experience may be achieved simultaneously.

Engineer/Scientist 3 Education: BS degree in Engineering, Computer Science, Information Systems, or related field. Experience: Six (6) years of experience in the area of information technology, to include: Technology Analysis and Assessment, Design Definition, Development of Systems Specification, Systems Analysis, Systems Architecture, Systems/Equipment Integration, Test & Evaluation Criteria, and Logistics support of C4ISR requirements. Five (5) years of technical experience in support of development, testing, and implementation of Department of Defense requirements, programs and/or projects. Experience may be achieved simultaneously.Descriptions for Engineer/Scientist 1 and 2 have been updated.
14170/ 176v/Factor 2: Past PerformanceProposal Organization/Past PerformanceIn the Proposal Organization, it states "5 pages per reference", however in the evaluation section, it states "cited past performance efforts shall not exceed three pages.
Question: Would the Government please clarify the page limit of the cited past performances?Past Performance References may be 5 pages. Section M has been updated.
15ATTACHMENT 11-1
PAST AND PRESENT PEFORMANCE INFORMATION, Section I, Page 2Background: For each contract reference, Attachment 11-1, Section I states the Offeror should "Specify, by name, any key individuals who participated in this program and are proposed to support the instant procurement. Also, indicate their contractual roles for both procurements."
Question: Will the Government define "key individuals"? Does "key individuals" specifically refer to Key Personnel as listed in the contract reference or does it encompass any notable, qualified personnel?Key individuals are required for past performance documentation and should not be confused with key personnel required at the task order level.
16ATTACHMENT 11-1
PAST AND PRESENT PEFORMANCE INFORMATION, Section E, Page 1 -2.Background: E. Completion Date: #2
Question: Would the Government please explain what is required for Current Schedule?Current Schedule refers to the current period of performance.
17174-175Section M,Addendum to 52.212-2(a), Evaluation-Commercial Items,
a. Basis for Contract AwardBackground: Section M states that "Section 508 Accessibility Standards do apply to this requirement. Section 508 requirements are listed in the Basic PWS and the attached Task Order 0001 PWS (Section J, Attachment 3). Compliance with Section 508 standards will be considered prior to evaluating any of the selection criteria listed below. Any proposal failing to meet the Section 508 Accessibility Standards, as listed in the Basic and Task Order 0001 PWSs, may be eliminated from consideration for award."
Question: How may the Offeror meet the Section 508 Accessibility Standards in its proposal? Is a statement of assent and agreement to comply with the Section 508 Accessibility Standards listed in the Basic PWS and the attached Task Order 0001 PWS sufficient to be compliant or does the Offeror's proposal itself need to meet the Section 508 Accessibility Standards?A statement of understanding, assent and agreement to comply with Section 508 Standards is sufficient for your response to the Basic PWS level and Task Order 0001. Reponses to future Task Orders may require Accessibility Conformance Reports or detailed Section 508 Compliance Plans which would be identified in the Task Order Requirement.
18Attachment_3_-_TO0001_PWSPage 1Does TO0001 include the survey, design, and implementation of the secondary SPPN at site C?The Contractor is not required to survey Site C under TO 0001. SPPN information for sites A, B, and C will be provided at award.
19196.1.2POA&MThe Government states, "The contractor shall coordinate with the Government to integrate the POA&M into the IMS to track the coordination of projects associated with USEUCOM. At the discretion of the Government, the contractor shall integrate the re-baselined POA&M into the IMS providing up to four intra-monthly IMS updates." An IMS is not a requirement in the PWS deliverable list.
Question: Will the Government please clarify if they want the contractor to provide an IMS, update the Government's IMS, or something else?The Government will draft the IMS and will require the contractor to integrate invidiual project POA&Ms into the IMS. The IMS itself is not a deliverable.
20Attachment 3_TO0001_PWS9Place of PerformanceWould the Governement provide the secure method options for providing the site names and locations, please? Would the Government provide a list of the site names and locations, please?The site names and locations are not required for proposal response. Site names and locations will be provided upon award and verification of Siprnet access. Other Direct Cost (ODC) Travel is provided as a plug number.
21171Section LL(b)(12)(vii)The instructions are silent on acceptable file formats for the sample IDP attachment. Are AutoCAD and Revit acceptable file formats? Will the Government allow the offeror to submit the IDP as a PDF?PDF for Sample IDP is acceptable.
22171Secton LL(b)(12)(vii)Table 1 describes a "Sample IDP or Migration/Cutover Plan for TO 0001 (OPTIONAL), but the Migration/Cutover Plan is omitted from (vii). What file format is acceptable for the Migration/Cutover Plan?The Sample Migration and Cutover plan may be provided as a .pdf or microsoft word document
23175Section MM(b) (1)Are there evaluation factors and subfactors associated with the "All other aspects of the PWS" section required by the Section L Volume II outline?The rated factors are described in Section M. All other aspects of the PWS will not be rated but need to be addressed in the proposal.
24175Section MM(b) (1)Are there evaluation factors/subfactors associated with the optional IDP?Sections L and M have been updated to require both a Sample IDP and a Sample Migration and Cutover Plan. The Sample IDP only may be provided on page size of 11x17. The Sample IDP and Sample Migration and Cutover Plan will not count against page limits. Evaluation Factor 1, Subfactor 1 has been updated.
25170Section LL(b)Will the Government please allow TNR 8 pt font for tables as well as graphics?The following applies to all documents: The page format shall have a 1-inch margin using no smaller than an 11-point Arial, Times New Roman, or Courier New font for all text to include any text contained in a table. Graphics shall have a text size with visual appearance equal to or greater than 8-point font
26169Section LL(12)(F)(iv)Will the Government allow 11 x 17 pages in the proposal for graphics?11x17 pages are only allowed for Sample IDPs. Section L has been updated.
2726.1.2Attachment 3 - TO 001 PWSParagraph 6.1.2 in the TO 001 PWS states, "Monthly updates for the POA&M and all other monthly project management artifacts shall be submitted simultaneously prior to the 10th of each month" but the summary table below paragraph 6.1.6 states that these updates are due by 10th of each month.
Question: Will the Government clarify these due dates to ensure they are consistent within TO 001 PWS?TO 0001 PWS has been updated.
2826.1.3Attachment 3 - TO 001 PWSParagraph 6.1.3 in the TO 001 PWS states, "Prior to the meeting, the contractor shall provide a Weekly Activity Report (WAR)" but the summary table below paragraph 6.1.6 states that the WAR is due 1 business day after the weekly meeting.
Question: Will the Government clarify these due dates to ensure they are consistent within the TO 001 PWS?TO 0001 PWS has been updated.
2986.8Attachment 3 - TO 001 PWSThe PWS Task summary table under paragraph 6.8 indicates that the SOVT is associated with PWS task 6.9.
Question: Will the Government clarify that the SOVT should be assocaited with PWS task 6.8?TO 0001 PWS has been updated.
301312Attachment 3 - TO 001 PWSThis section for Government Furnished Property (GFP)/Government-Furnished Equipment (GFE)/ Government-Furnished Information (GFI) shows N/A but there are references to the potential for access to classifed systems.
Question: Will the Government clarify if GFP/GFE/GFI are associated with this TO 001 PWS?TO 0001 PWS has been updated.
31169Section LL (12)(iv)Question: Which Volume shall the Section 508 Accessibility Standards compliance statement be submitted?The Section 508 Accessibility Standards response may be submitted in Volume V. Section L has been updated.
32169Section LL (12)(iv) Table 1What documentation shall be provided in Volume V: Contract Documentation: Other documentation as needed?Section L has been updated to remove "Other Documentation as Needed"
3385Security ClearancesHC102823R0032.pdfFor a contractor teaming arrangement where one member has a Top Secret Facility Site Clearance, would the government be willing to sponsor the clearance of the member that does not have a facility at the time of award?Both parties of the Joint Venture (JV) must have the required Facility Clearance Level (FCL) at the time of award to be eligible for award. Please see Section H.
3477Section 2, Paragraph CHC102823R0032.pdfTask Order Key Personnel. Does the government plan to require task order key personnel to be proposed with a Letter of Commitment?Key personnel requirements will be determined at the Task Order Level. Key personnel are not required for Task Order 0001. Letters of Commitment will not be required.
35168Paragraph DHC102823R0032.pdfDD Form 254. Would the government consider accepting the provision of valid email addresses (address removed) up until July 5, 2023?The requirement to provide a valid email address was removed in Amendment 1 to the solicitation.
36Would the Government consider a 30 day extension from the July 24, 2023 response date?The proposal due date has been extended to July 31, 2023.
37Is this a brand new contract or is an incumbent performing these services? Could you please provide the current/previous contract number?The information requested is on page 14 of the RFP.