Visio-DITCO_WiringDiagrams.pdf

PDF 1 MB Posted

Attached to
DITCO SCOTT Facility Maintenance Federal contract opportunity
Solicitation number
HC102819R0072
Issued by
Defense Information Systems Agency

About this file

Building Automation System / Site Monitoring System Schematics

View the file

Other files for this federal contract opportunity

Other files attached to DITCO SCOTT Facility Maintenance, newest first.
File Type Posted
2019_01_MGE_UPS.pdf PDF
HC102819R0072_-_Amendment_00002.pdf PDF
2019_01_Telcom_UPS.pdf PDF
2019_05_Battery_Cabinet.pdf PDF
AMD0002_-Questions_-_Government_Response_(003).xlsx XLSX spreadsheet
3.jpg JPG image
1.jpg JPG image
5.jpg JPG image
NEW_TRANE_HVAC_REPLACEMENTS_20_TON_AND_42_TONSl.pdf PDF
6.jpg JPG image
4.jpg JPG image
HC102819R0072_-_AMD0001.pdf PDF
2.jpg JPG image
NDA.docx DOCX document
HC102819R0072.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

11902 LACKLAND ROAD

ST. LOUIS, MISSOURI 63146

(314) 993-3355

THE BICK GROUP

G R O U P

SH

EE

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

IO

N

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Network Manager 587-725

Panel Layout (34x20)

Power Supply 2

Power Supply 1

A/C Unit 2

DGM

Network Manager 587-725

120 VAC

120 VAC

120 VAC

24 VAC

24 VAC

To Network connection

Network Manager 587-725

Lon Trunk Wiring

A/C Unit 3

DGM

A/C Unit 4

DGM

A/C Unit 5

DGM

A/C Unit 6

DGM

Power Supply 1 Power Supply 1

24 VAC

24 VAC

Site Monitoring System Topology

PDU Unit

3 DGM

PDU Unit

2 DGM

PDU Unit

1 DGM

Network Manager 1 Panel Layout and Site Monitoring Topology

A/C Unit Phone Room

DGM

Power Source

TBD

New PAC Controller

N et w or k M an ag er

P an el L ay ou t a nd

S ite

M on ito rin g To po lo gy

Notes:

1. Lower level lon devices to be connected to network manager #1. Devices shown on BC - X.

CP-CR-A

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Computer Room

FTU 12

Lon Trunk

VAV 8 FTU 11VAV 7

24 VAC

24 VAC

Network Manger 1 Lon and Power Trunk

N et w or k m an ge r 1 L on a nd P ow er

T ru nk

Network Manager

Network Manager 587-726

T

VAV 9

CP-123-E

3 controllers

Lon Trunk

Lon Trunk

CP-CR-A

T = Space temperature sensor attached

Nose-5

AHU -4

CP-123-A

4 controllers

Main Mechanical Room 123

T T T T

To Site Monitoring Equipment shown on prior page

Lon TrunkLon Trunk

Lon Trunk

Lon Trunk

24 VAC

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Talon Small Building Network

Manager 587-724

Lon Trunk

Ethernet Port

RS-232

Serial Port

RS-485

Serial Port

Shield

- B-

B+

EGD

X2

CT

X1

UI1 G UI2 UI3 G UI4 UI5 G UI6 V+ G V+ NC1 C1 NO1NC2 C2 NO2 NC3 C3NO3NC4 C4 NO4

Inputs Outputs

Power Connection already connected from 120V source

Lon Trunk Connection

24 VAC Power Trunk

Lon Trunk Connection

24 VAC Power Trunk

TB - Power Lon

A/C Common Alarm

Air Conditioning Alarm

Underfloor Water DetectorOrange

Yellow

Red

White

WD - 1

H

T

RH & T Sensor

Notes:

1. 120VAC Power to be connected to main power connection in

SMP.

2. Mount Water Detector under raised access floor, directly in front of air conditioning unit.

3. Mount Discharge Temp and Humidity sensor directly in the airflow path of the airconditioning unit under the raised access floor.

Network Manager 1 Wiring

N et w or k M an ag er

W iri ng

LonWorks Network Wiring Requirem ents:

Max. Total W ire Length

Max.

N ode to N ode Length

Max. Total Wire Length (N ote 2)

Max. N ode to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Notes:

1. Level 4 cable per NEMA standards (not equivalent to E IA /TIA Level 4 cable).

W indy C ity # 105540/S = 1000 ft spool.

2. Bus topology has a stub length limit of 10 ft. maximum.

Predator Controller Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to E IA /TIA Level 4 cable).

†Available in fixed lengths of 25, 50, and 100 feet

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

C onnection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation 32wire, 18AWG cable 22 AW G TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Lon Trunk Connection

24 VAC Power Trunk

Lon Trunk Connection

24 VAC Power Trunk

TB - Power Lon

E N H

NETWORK

CONNECTION

IN 1

IN 2

IN 3

IN 4

IN 5

IN 6

OUT A1

OUT A2

OUT A3

OUT D2

OUT D1

OUT D5

OUT D6

OUT D4

OUT D3

OUT D8

OUT D7

BST

TALON

Predator Board Type:

Full

Notes:

1. 24VAC Power to be connected to power supply in SMP on 24

VAC Power Supply.

2. Network connection to be connected to Network Manager LON connection

3. DGM units to be installed in SMP.

4. Mount CT units on phase conductors at main input of PDU.

5. Tie to common alarm relay of respective PDU.

Legend

Predator / Raptor Controller Connection

Field Device Termination

Keyed Notes1

LonWorks Network Wiring Requirem ents:

Max. Total W ire Length

Max.

N ode to N ode Length

Max. Total Wire Length (N ote 2)

Max. N ode to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Notes:

1. Level 4 cable per NEMA standards (not equivalent to E IA /TIA Level 4 cable).

W indy C ity # 105540/S = 1000 ft spool.

2. Bus topology has a stub length limit of 10 ft. maximum.

Predator Controller Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to E IA /TIA Level 4 cable).

†Available in fixed lengths of 25, 50, and 100 feet

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

C onnection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AW G TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

CT

Phase 1 Current

CT

Phase 2 Current

CT

Phase 3 Current

1 2

Summary Alarm PDU Summary Alarm

Site Monitoring / PDU Units

Si te

M on ito rin g / P

D U

U ni ts

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

H

T

RH & T Sensor

24VDC Out 24VAC In

+ -- H G

DCP-1.5-W

Cut Jumper J3 and install jumper between 24VDC --terminal and 24VAC G terminal

E N H

NETWORK

CONNECTION

IN 1

IN 2

IN 3

IN 4

IN 5

IN 6

OUT A1

OUT A2

OUT A3

OUT D2

OUT D1

OUT D5

OUT D6

OUT D4

OUT D3

OUT D8

OUT D7

BST

TALON

Predator Board Type:

Full

A/C Common Alarm

Air Conditioning Alarm

H

T

RH Sensor

Site Monitoring / Air Conditioning Units

T-2T-3

T-1

Lon Trunk Connection

24 VAC Power Trunk

Lon Trunk Connection

24 VAC Power Trunk

TB - Power Lon

Notes:

1. 24VAC Power to be connected to power supply in SMP 1 Via 24

VAC Power Trunk.

2. Network connection to be connected to TB-Power/Lon terminal block in SMP 1 via Lon Trunk.

3. DGM units to be installed in 18" x12" x 6" Enclosure Mounted under raised access floor.

4. On DGM 5 omit temperature room sensor.

5. Mount Water Detector under raised access floor, directly in front of air conditioning unit.

6. Mount Discharge Temp and Humidity sensor directly in the airflow path of the airconditioning unit under the raised access floor.

7. Mount Room Sensors @ 5' 0" AFF at location (TBD).

Underfloor Water DetectorOrange

Yellow

Red

White

WD - 1

TB - Power Lon 3

TB - Power Lon 4

1 2

Si te

M on ito rin g / A ir C on di tio ni ng U ni ts

Legend

Predator / Raptor Controller Connection

Field Device Termination

Keyed Notes1

LonWorks Network Wiring Requirem ents:

Max. Total Wire Length

Max.

N ode to N ode Length

Max. Total Wire Length (Note 2)

Max. N ode to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Notes:

1. Level 4 cable per NEMA standards (not equivalent to E IA /TIA Level 4 cable).

W indy C ity # 105540/S = 1000 ft spool.

2. Bus topology has a stub length limit of 10 ft. maximum.

Predator Controller Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to E IA /TIA Level 4 cable).

†Available in fixed lengths of 25, 50, and 100 feet

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

C onnection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

R ecommendation 32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

Room Sensor - Connect to back of controller with Factory supplied cable

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Existing panel - Houses existing relay interface to moter control starters.

Also houses pnematic controls, to be removed.

Existing Panel - Field wiring connections to existing field devices.

New Control panel CP-123 A

2" Conduit

1" Conduit to devices

1/2" Conduit for Power

Functional Devices

PSH75A

Power Supply

Predator Controller #123 - 1

Plant

Predator Controller #123 - 2

Plant

Predator Controller #123 - 3

Plant

Predator Controller #123 - 4

Plant

TB

-1

Mechanical Room 123 Panel Layout Sheet 1

CP-123 B

CP-123 C

M ec ha ni ca l R oo m

P an el L ay ou t S he et

Notes:

1: Use existing power circiut from CP-123c.

2: Power Supply detail on controller wiring pages.

Functional Devices

PSH75A

Power Supply panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

TB-2

PSM

Power Supply

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Mechanical Room 123 Heating & Cooling Plant Sequence of Operation page 1

M ec ha ni ca l R oo m

H ea tin g

C oo lin g Pl an t S eq ue nc e of O pe ra tio n pa ge

FREE COOLING LOOP CONTROL SEQUENCE

System Description: The free cooling circuit is condenser water for those air condition units not anticipated to operate in a cooling mode more than 14 hours per day. This loop provides condenser water during warm outside conditions and cold “free cooling” water during winter. The free cooling pumps (FCP – 1 & 2) operate continuous, one operating and one stand-by, to be alternated weekly by the BAS.

Sequence of operation:

Lead pump operates continuous.

Evaporator fan and pump control:

Outside air grater than 70 degrees F wet bulb, 34 BTU/#.

Evaporative cooler spray pump and fan motor speeds are all staged to provide 85 degrees F supply water temperature by BAS.

Outside air less than 70 degrees F wet bulb, 34 BTU/#.

Evaporative cooler spray pump and fan motor speeds are all staged to provide 45 degrees F supply water temperature by BAS.

With outdoor air temperature less than 35 degrees F spray pumps are de-energized by BAS, and basin heaters operate to hold 40 degrees basin water temperature by local temperature sensor.

0 deg F 60 deg F

120 deg F

125 deg F

HEAT RECOVERY LOOP CONTROL SEQUENCE

System Description: The heat recovery circuit supplies condenser water to air conditioning units that operates with a continuous significant cooling load. This circuit will provide waste heat for building heating. The operating temperature of the heat recovery circuit is controlled by the amount of heat rejected to the free cooling circuit thru the three way interface valve, or by free cooling provided thru the free cooling secondary loop. Similar to the free cooling pumps (FCP – 1 & 2), the free cooling secondary pumps (FCSP – 1 & 2) and heat recovery pumps (HRP – 1 & 2) are alternated weekly for equalized run time and status indication by the BAS.

Sequence of operation:

Outside air greater than 70 degrees Fahrenheit wet bulb, 34 BTU/#. Heat recovery and free cooling operation.

Free cooling secondary pumps are off.

The lead heat recovery pump operates continuous.

The three way interface valve (V-1) opens to maintain maximum 120 degrees return water temperature in the heat recovery circuit.

Outside air less than 70 degrees Fahrenheit wet bulb, 34 BTU/#. Heat recovery and free cooling operation.

Lead free cooling secondary pump operates continuous.

Lead heat recovery pump operates continuous.

If the heat recovery circuit return temperature at T-2 falls below the reset schedule T-2, valves V-1 and V-2 operate in sequence as follows:

The three way interface valve V-2 modulates closed to the free cooling loop to reduce free cooling and promote mechanical cooling in the computer area causing heat to be rejected to the heat recovery loop.

After V-2 is closed and the temperature at T-2 continues to fall the three way interface valve V-1 modulates closed to retain heat in the heat recovery circuit by closing to the free cooling loop.

If the heat recovery circuit return temperature at T-2 rises above the reset schedule T-2, valves V-1 and V-2 operate in the sequence as follows:

The three way interface valve V-2 modulates open to the free cooling loop to permit free cooling in the computer area reducing the heat rejection rate to the heat recovery loop to maintain the reset schedule T-2.

Reset Schedule T-2

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Mechanical Room 123 Heating & Cooling Plant Sequence of Operation page 2

M ec ha ni ca l R oo m

H ea tin g

C oo lin g Pl an t S eq ue nc e of O pe ra tio n pa ge

SPACE HEATING LOOP SEQUENCE OF OPERATION

System Description: The boiler (HWB-1) is equipped to stage its operation in a 13 steps via analog signal from the BAS, which will maintain the reset schedule shown for T-3 on the system schematic M-14. Hot water supply temperature is reset inversely with outdoor air temperature similar to the heat recovery loop, but five degrees lower to keep the boiler off line when the heat recovery loop is able to meet the load. Hot water pumps (HWP- 1 & 2) are equipped with differential pressure switches for status monitoring, and will be staged weekly by the BAS.

Sequence of operation:

Lead hot water pump operates continuous. Pumps are sequenced weekly to maintain even wear on pumps.

The two position, three way interface valve (V-3) is used to separate the space heating loop from the heat recovery loop, when heat recovery loop is unable to maintain at a minimum, 5 deg F warmer water than the hot water return. V-3 will also be used to isolate the hot water loop for maintenance purposes.

0 deg F 60 deg F

115 deg F

120 deg F

Reset Schedule T-3

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

DI Source Signal + Common -

Lon Network

IN1

DI Source Signal + Common -

IN2

DI Source Signal + Common -

IN3

DI Source Signal + Common -

IN4

DI Source Signal + Common -

IN5

DI Source Signal + Common -

IN6

Common Signal Out

OUTA1

Common Signal Out

OUTA2

Common Signal Out

OUTA3

24VAC

Triac Sw

OUTD1

24VAC

Triac Sw

OUTD2

24VAC

Triac Sw

OUTD3

24VAC

Triac Sw

OUTD4

24VAC

Triac Sw

OUTD5

24VAC

Triac Sw

OUTD6

24VAC

Triac Sw

OUTD7

4224VAC

Triac Sw

OUTD8

H N E

Controller A-123-1 587-292 Staefa 4 Loop

OR

OR

panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

Notes:

1. Predator common terminals are internally connected to neutral.

2. Terminal blocks have the panel letter designation before the terminal number on each block. The designation MS is for the moter starter terminal strip in panel C.

3. Terminal Block C-TB-MS is an existing terminal block in the C enclosure. Relay outputs to be tied to these outputs, and existing terminal #s will be added to AS BUILT DRAWINGS.

4. Terminal Block B-TB is an existing terminal block in the B enclosure. Existing device wiring runs to these blocks, that will be tied to controller inputs. Terminal #s will be added to AS BUILT

DRAWINGS.

5 . Power Supply wiring shown on Page 2 of the 123-A panel wiring diagrams.

(Not Polarity Sensitive) LonTalk TP/FT-10 LonTalk TP/FT-10

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mA

A-TB1

ohm

T1 - 24V AC Line T1 - 24V AC Neutral T1 - Ground

PSM - 24V DC "+"

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mAPSM - 24V DC "+" ohm

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mAPSM - 24V DC "+" ohm

Room Sensor - Connect to back of controller with Factory supplied cable

587-184

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

RIBMN24S Panel 123 -C

C-TB-MS

RIBMN24S Panel 123 -C

FCP-1(Tower Pump) Status

FCP-2 (Tower Pump) Status

FC Supply Water Temp (From Tower)

FC Total Return Water Temp (To Tower)

FC Loop Return Water Temp (Before Pumps)

FCP-1(Tower Pump)

FCP-2(Tower Pump)

MST - xxx MST - xxx MST - xxx MST - xxx

Mechanical Room Panel 123-A Wiring Sheet 1

M ec ha ni ca l R oo m

P an el

-A

W iri ng S he et

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

DI Source Signal + Common -

Lon Network

IN1

DI Source Signal + Common -

IN2

DI Source Signal + Common -

IN3

DI Source Signal + Common -

IN4

DI Source Signal + Common -

IN5

DI Source Signal + Common -

IN6

Common Signal Out

OUTA1

Common Signal Out

OUTA2

Common Signal Out

OUTA3

24VAC

Triac Sw

OUTD1

24VAC

Triac Sw

OUTD2

24VAC

Triac Sw

OUTD3

24VAC

Triac Sw

OUTD4

24VAC

Triac Sw

OUTD5

24VAC

Triac Sw

OUTD6

24VAC

Triac Sw

OUTD7

4224VAC

Triac Sw

OUTD8

H N E

Controller A-123-2 587-292 Staefa 4 Loop

A-TB1

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mA

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mA

C-TB-MS

RIBMN24S Panel 123 -C

RIBMN24S Panel 123 -C MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx

PSM - 24V DC "+"

ohm ohm

PSM - 24V DC "+"

T1 - 24V AC Line T1 - 24V AC Neutral T1 - Ground

FCSP-1(Sec Free Cool Pump) Status

SFCS Supply Water Temp (For Sec Loop)

FCSP-1(Sec Free Cool Pump)

FCSP-2(Sec Free Cool Pump) Status

HRP-1(Heat Rejection Pump) Status

HRP-2(Heat Rejection Pump) Status

SFCR Return Water Temp (For Sec Loop)

RIBMN24S Panel 123 -C

RIBMN24S Panel 123 -C

FCSP-2(Sec Free Cool Pump)

HRP-1(Heat Rejection Pump)

HRP-2(Heat Rejection Pump)

RIBMN24S Panel 123 -C MST - xxx MST - xxx Main Mech Room Exhaust Fan

Ventilation Air Damper

2 GMA121.1P

1 Actuator

Main Mech Room Ventalation Damper

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Boiler SST Circuit

DI Source Signal + Common -

Lon Network

IN1

DI Source Signal + Common -

IN2

DI Source Signal + Common -

IN3

DI Source Signal + Common -

IN4

DI Source Signal + Common -

IN5

DI Source Signal + Common -

IN6

Common Signal Out

OUTA1

Common Signal Out

OUTA2

Common Signal Out

OUTA3

24VAC

Triac Sw

OUTD1

24VAC

Triac Sw

OUTD2

24VAC

Triac Sw

OUTD3

24VAC

Triac Sw

OUTD4

24VAC

Triac Sw

OUTD5

24VAC

Triac Sw

OUTD6

24VAC

Triac Sw

OUTD7

4224VAC

Triac Sw

OUTD8

H N E

Controller A-123-3 587-292 Staefa 4 Loop panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

Notes:

1. Predator common terminals are internally connected to neutral.

2. Terminal blocks have the panel letter designation before the terminal number on each block. The designation MS is for the moter starter terminal strip in panel C.

3. Terminal Block C-TB-MS is an existing terminal block in the C enclosure. Relay outputs to be tied to these outputs, and existing terminal #s will be added to AS BUILT DRAWINGS.

4. Terminal Block B-TB is an existing terminal block in the B enclosure. Existing device wiring runs to these blocks, that will be tied to controller inputs. Terminal #s will be added to AS BUILT

DRAWINGS.

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mA

A-TB1

ohm

T1 - 24V AC Line T1 - 24V AC Neutral T1 - Ground

PSM - 24V DC "+"

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mAPSM - 24V DC "+" ohm

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mAPSM - 24V DC "+" ohm

GR

PSH75A

120V/24V - 75 VA

Transformer

T1 T1 - 24V AC Line T1 - 24V AC Neutralblue yellow

T1 - Groundgn

120V AC Line 120V AC Neutral Ground

A-TB2

120 VAC

PSM - 24 VDC --

PSM

Note : Bond Neutral and Ground to earth ground, on secondary of T1. Also tie 24 VDC -- to earth ground on PSM.

PSM - 24 VDC +

PSH75A

120V/24V - 75 VA

Transformer

T2 T2 - 24V AC Line T2 - 24V AC Neutralblue yellow

T2 - Groundgn

Enclosure A Power Supply Detail

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

Contact provided by flow switch on pumps.

B-TB-xxx B-TB-xxx

RIBMN24S Panel 123 -C

C-TB-MS

RIBMN24S Panel 123 -C

HWP-1(Hot Water Pump) Status

HWP-1 (Hot Water Pump)MST - xxx MST - xxx MST - xxx MST - xxx

Mechanical Room Panel 123-A Wiring Sheet 2

M ec ha ni ca l R oo m

P an el

-A

W iri ng S he et

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

HRS Supply Water Temp (Heat Recovery Loop)

Secondary Loop Free Cooling Valve (V-2) Modulating

Surface Mount Pipe Sensor536-780 544-343- 100 ohm RTD

+ 4-20mAPSM - 24V DC "+" ohm

U G

GO

Y Gray

Blk

Pink Red

0 -10

VDC

Modulating valve

U G

GO

Y Gray

Blk

Pink Red

0 -10

VDC

Modulating valve

HWP-2 (Hot Water Pump)

HWP-2(Hot Water Pump) Status

T1 - 24V AC Line T1 - 24V AC Neutral

T1 - 24V AC Line T1 - 24V AC Neutral

Heat Recovery Loop Valve (V-1) Modulating

HRR Return Water Temp (Heat Recovery Loop)

HWS Supply Water Temp (Hot Water Loop)

HWR Return Water Temp (Hot Water Loop)

2 2 position 1 Actuator

Hot Water Loop Valve (V-3) 2 position

LonTalk TP/FT-10 LonTalk TP/FT-10 To TB-OR / OR

RIBU1C Boiler Control Panel Boiler SST Interlock

Boiler 4/20 ma Reset Circuit

Boiler Reset Signal

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

DI Source Signal + Common -

Lon Network

IN1

DI Source Signal + Common -

IN2

DI Source Signal + Common -

IN3

DI Source Signal + Common -

IN4

DI Source Signal + Common -

IN5

DI Source Signal + Common -

IN6

Common Signal Out

OUTA1

Common Signal Out

OUTA2

Common Signal Out

OUTA3

24VAC

Triac Sw

OUTD1

24VAC

Triac Sw

OUTD2

24VAC

Triac Sw

OUTD3

24VAC

Triac Sw

OUTD4

24VAC

Triac Sw

OUTD5

24VAC

Triac Sw

OUTD6

24VAC

Triac Sw

OUTD7

4224VAC

Triac Sw

OUTD8

H N E

Controller A-123-4 587-292 Staefa 4 Loop panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

Notes:

1. Predator common terminals are internally connected to neutral.

2. Terminal blocks have the panel letter designation before the terminal number on each block. The designation MS is for the moter starter terminal strip in panel C.

3. Terminal Block C-TB-MS is an existing terminal block in the C enclosure. Relay outputs to be tied to these outputs, and existing terminal #s will be added to AS BUILT DRAWINGS.

4. Terminal Block B-TB is an existing terminal block in the B enclosure. Existing device wiring runs to these blocks, that will be tied to controller inputs. Terminal #s will be added to AS BUILT

DRAWINGS.

A-TB1

T1 - 24V AC Line T1 - 24V AC Neutral T1 - Ground

GR

PSH75A

120V/24V - 75 VA

Transformer

T1 T1 - 24V AC Line T1 - 24V AC Neutralblue yellow

T1 - Groundgn

120V AC Line 120V AC Neutral Ground

A-TB2

120 VAC

PSM - 24 VDC --

PSM

Note : Bond Neutral and Ground to earth ground, on secondary of T1. Also tie 24 VDC -- to earth ground on PSM.

PSM - 24 VDC +

PSH75A

120V/24V - 75 VA

Transformer

T2 T2 - 24V AC Line T2 - 24V AC Neutralblue yellow

T2 - Groundgn

Enclosure A Power Supply Detail

RIBMN24S Panel 123 -C

C-TB-MS

RIBMN24S Panel 123 -C

MST - xxx MST - xxx MST - xxx MST - xxx

Mechanical Room Panel 123-A Wiring Sheet 3

M ec ha ni ca l R oo m

P an el

-A

W iri ng S he et

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

Evaporative Cooler 1 Low Speed

Contact provided on moter starter.

TB-MS-xxx TB-MS-xxx

Contact provided on moter starter.

TB-MS-xxx TB-MS-xxx

Contact provided on moter starter.

TB-MS-xxx TB-MS-xxx

Contact provided on moter starter.

TB-MS-xxx TB-MS-xxx

Contact provided on moter starter.

TB-MS-xxx TB-MS-xxx

Contact provided on moter starter.

TB-MS-xxx TB-MS-xxx

RIBMN24S Panel 123 -C

RIBMN24S Panel 123 -C

RIBMN24S Panel 123 -C

RIBMN24S Panel 123 -C

MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx MST - xxx

Evaporative Cooler 1 High Speed

Evaporative Cooler 1 Spray Pump

Evaporative Cooler 2 Low Speed

Evaporative Cooler 2 High Speed

Evaporative Cooler 2 Spray Pump

Evaporative Cooler 1 Low Speed Status

Evaporative Cooler 1 High Speed Status

Evaporative Cooler 1 Spray Pump Status

Evaporative Cooler 2 Low Speed Status

Evaporative Cooler 2 High Speed Status

Evaporative Cooler 2 Spray Pump Status

LonTalk TP/FT-10 LonTalk TP/FT-10 To TB-OR / OR

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Existing Panel - Field wiring connections to existing field devices.

Conduit to dedicated Branch Circuit.

Circuit to be determined in field.

Functional Devices

PSH75A

Power Supply

TB

-1

Predator Controller #123 - 5

AHU - 5

Predator Controller #123 - 6

AHU - 8

Mechanical Room 123 Panel Layout Sheet 2

M ec ha ni ca l R oo m

P an el L ay ou t S he et

Predator Controller #123 - 7

AHU - 6

TB

-2

PSM

Power Supply

New Control panel CP-123 E

CP-123 D

Re la ys Re la ys

Re la ys

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable† panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

GR

PSH75A

120V/24V - 75 VA

Transformer

T1 T1 - 24V AC Line T1 - 24V AC Neutralblue yellow

T1 - Groundgn

120V AC Line 120V AC Neutral Ground

TB2

120 VAC

PSM - 24 VDC --

PSM

Note : Bond Neutral and Ground to earth ground, on secondary of T1. Also tie 24 VDC -- to earth ground on PSM.

PSM - 24 VDC +

Enclosure E Power Supply Detail

Notes:

1: Power to panel E to be run from a dedicated branch circuit, from UPS power.

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Return Air

POWERS

L H

FI

LT

E R

D X

C oi l

Supply Air Temp

Existing

Differential Pressure Switch

Kele

ST-024-XH

Use Existing Duct Smoke Detector, to stop fan if activated.

AHU-5: UPS room Cooling

Fan Status Veris H900

Current Switch Return Air

Temp Kele

ST-024-XH

Fan Start Stop by BAS Staefa

587-184 Space

Sensor w/ Override

Setpoint

Room sensor located in controlled space.

CONSTANT VOLUME, SELF-CONTAINED, WATER COOLED AIR CONDITIONING UNIT (AC – 5)

System Description: Constant volume, self-contained, water cooled air conditioning unit. Interface with BAS provides remote on off, temperature control, and status indication for maintenance support. Due to constant and critical load on this unit, night set back is not appropriate for this unit. Unit is not provided with heat.

Sequences:

Unit fan runs continuous. Stop fan on smoke detection in unit discharge duct.

1. Room temperature control. A Room temperature sensor on the BAS, sequences cooling to maintain, 70 deg F (adj) room temperature.

2. A unit-mounted water-regulating valve controlled by refrigerant circuit head pressure modulates the water flow thru the heat exchanger (water cooled condenser).

BAS will monitor, discharge air temperature, return air temperature, mixed air temperature, fan, and filter status.

AHU 5 Simple Flow Diagram & Sequence of Operation

A H

U

S im pl e

Fl ow

D ia gr am

S eq ue nc e of O pe ra tio n2 stage

DX controlled by BAS.

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

DI Source Signal + Common -

Lon Network

IN1

DI Source Signal + Common -

IN2

DI Source Signal + Common -

IN3

DI Source Signal + Common -

IN4

DI Source Signal + Common -

IN5

DI Source Signal + Common -

IN6

Common Signal Out

OUTA1

Common Signal Out

OUTA2

Common Signal Out

OUTA3

24VAC

Triac Sw

OUTD1

24VAC

Triac Sw

OUTD2

24VAC

Triac Sw

OUTD3

24VAC

Triac Sw

OUTD4

24VAC

Triac Sw

OUTD5

24VAC

Triac Sw

OUTD6

24VAC

Triac Sw

OUTD7

4224VAC

Triac Sw

OUTD8

H N E

Controller E-123-5 587-286 Staefa UV DX panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

Notes:

1. Predator common terminals are internally connected to neutral.

2. Terminal blocks have the panel letter designation before the terminal number on each block.

3. Tie controller outputs to thermostat low voltage inputs to control AHU.

4. Install Hawkeye current switch around one phase conductor or the main fan power circuit, after the fan contactor.

5. No outside air on AHU 5.

6. Input 6 to be used for compressor 2 status on AHU 6.

E-TB1

T1 - 24V AC Line T1 - 24V AC Neutral T1 - Ground

Mechanical Room Panel 123-E AHU 5 Wiring

M ec ha ni ca l R oo m

P an el

-E

A H

U

W iri ng

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

Discharge Air Temperature Sensor

GR

PSH75A

120V/24V - 75 VA

Transformer

T1 T1 - 24V AC Line T1 - 24V AC Neutralblue yellow

T1 - Groundgn

120V AC Line 120V AC Neutral Ground

TB2

120 VAC

PSM - 24 VDC --

PSM

Note : Bond Neutral and Ground to earth ground, on secondary of T1. Also tie 24 VDC -- to earth ground on PSM.

PSM - 24 VDC +

Enclosure E Power Supply Detail

ST-D24-XH Duct Sensor10K OHM

ST-D24-XH Duct Sensor10K OHM

Existing DP Switch.

Note: IN 5 is not avalible.

Must be configured as a Low Temp. Sensor not used.

RIBMN24S Panel 123 -E

RIBMN24S Panel 123 -E

T1 - 24V AC Line

T1 - 24V AC Neutral

RIBMN24S Panel 123 -E

Return Air Temperature Sensor

Fan Status Indication

Filter Status Indication

H900 Hawkeye Current Switch

Fan Start Stop G R

Room Sensor - Connect to back of controller with Factory supplied cable

587-184

G Y1 Cooling Stage 1

Y2 G Cooling Stage 2

LonTalk TP/FT-10 LonTalk TP/FT-10OR

OR

H900 Hawkeye Current Switch

Compressor 2 AHU 6 Status Indication

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Return Air

POWERS

L H

FI

LT

E R

D X

C oi l

Supply Air Temp

Existing

Differential Pressure Switch

Kele

ST-024-XH

Use Existing Duct Smoke Detector, to stop fan if activated.

AHU-8 : NW Lower Level

Fan Status Veris H900

Current Switch

Return Air Temp Kele

ST-024-XH

Fan Start Stop by BAS 2 stage DX controlled by BAS.

Staefa 587-184 Space

Sensor w/ Override

SetpointRoom sensor located in controlled space.

AHU 8 Simple Flow Diagram & Sequence of Operation

A H

U

S im pl e

Fl ow

D ia gr am

S eq ue nc e of O pe ra tio n

Ave Mixed Air Temp Staefa

535-493

Outside Air Damper 2 position spring return

Siemens

GCA-121-1U

Damper operation by BAS

CONSTANT VOLUME, SELF-CONTAINED, WATER COOLED AIR CONDITIONING UNIT (AC – 8)

System Description: Constant volume, self-contained, water cooled air conditioning unit. Interface with BAS provides remote on off, and temperature control and status indication for maintenance support. Night set back will be accomplished via the BAS control of the unit. Unit is not provided with heat, as space heating is done via the fan terminal units.

Sequence:

Unoccupied: Unit fan is off. Outside air damper closes any time the fan stops.

Occupied: Unit fan runs continuous, outside air damper opens, via BAS outputs. Stop fan on smoke detection in unit discharge duct.

1. Room temperature control. A Room temperature sensor on the BAS, sequences cooling to maintain 74 deg F (adj) room temperature during occupied operation, and 78 deg F (adj) during unoccupied operation.

2. A unit-mounted water-regulating valve controlled by refrigerant circuit head pressure modulates the water flow thru the heat exchanger (water cooled condenser).

BAS will monitor, discharge air temperature, return air temperature, mixed air temperature, fan, and filter status.

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

DI Source Signal + Common -

Lon Network

IN1

DI Source Signal + Common -

IN2

DI Source Signal + Common -

IN3

DI Source Signal + Common -

IN4

DI Source Signal + Common -

IN5

DI Source Signal + Common -

IN6

Common Signal Out

OUTA1

Common Signal Out

OUTA2

Common Signal Out

OUTA3

24VAC

Triac Sw

OUTD1

24VAC

Triac Sw

OUTD2

24VAC

Triac Sw

OUTD3

24VAC

Triac Sw

OUTD4

24VAC

Triac Sw

OUTD5

24VAC

Triac Sw

OUTD6

24VAC

Triac Sw

OUTD7

4224VAC

Triac Sw

OUTD8

H N E

Controller E-123-6 587-286 Staefa UV DX panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

Notes:

1. Predator common terminals are internally connected to neutral.

2. Terminal blocks have the panel letter designation before the terminal number on each block.

3. Tie controller outputs to thermostat low voltage inputs to control AHU.

4. Install Hawkeye current switch around one phase conductor or the main fan power circuit, after the fan contactor.

5. Nose monitor will control OA damper of both AHU #6 and AHU #8.

The monitor will be mounted on Unit #6. OA is pulled from the same source.

E-TB1

T1 - 24V AC Line T1 - 24V AC Neutral T1 - Ground

Mechanical Room Panel 123-E AHU 8 Wiring

M ec ha ni ca l R oo m

P an el

-E

A H

U

W iri ng

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

Discharge Air Temperature Sensor

GR

PSH75A

120V/24V - 75 VA

Transformer

T1 T1 - 24V AC Line T1 - 24V AC Neutralblue yellow

T1 - Groundgn

120V AC Line 120V AC Neutral Ground

TB2

120 VAC

PSM - 24 VDC --

PSM

Note : Bond Neutral and Ground to earth ground, on secondary of T1. Also tie 24 VDC -- to earth ground on PSM.

PSM - 24 VDC +

Enclosure E Power Supply Detail

ST-D24-XH Duct Sensor10K OHM

ST-D24-XH Duct Sensor10K OHM

Contact provided Air Handling Unit.

Note: IN 5 is not avalible. Must be configured as a Low Temp. Sensor not used.

RIBMN24S Panel 123 -E

RIBMN24S Panel 123 -E

T1 - 24V AC Line

T1 - 24V AC Neutral

RIBMN24S Panel 123 -E

RIBMN24S Panel 123 -E

Return Air Temperature Sensor

Fan Status Indication

Filter Status Indication

H900 Hawkeye Current Switch

Fan Start Stop

Outside Air 2 Position Damper Ventilation Air

Damper

2 GMA121.1P

1 Actuator

G Y1

Y2

G

G

R

Cooling Stage 1

Cooling Stage 2

Room Sensor - Connect to back of controller with Factory supplied cable

587-184

PSM - 24V DC "+"

36 " Duct Ave.

Sensor535-493 544-343- 100 ohm RTD + 4-20mA ohm

Mixed Air Temperature Sensor

LonTalk TP/FT-10 LonTalk TP/FT-10 To TB-OR / OR

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Return Air

FI

LT

E R

D X

C oi l

Supply Air Temp

Existing

Kele

ST-024-XH

Use Existing Duct Smoke Detector, to stop fan if activated.

AHU-6 : VAV Lower Level VAV units - 7, 8, & 9.

Fan Terminal Units - 11, & 12.

Fan Status Veris H900

Current Switch

Return Air Temp Kele

ST-024-XH

Fan Start Stop by BAS

AHU 6 Simple Flow Diagram & Sequence of Operation

A H

U

S im pl e

Fl ow

D ia gr am

S eq ue nc e of O pe ra tio n

Ave Mixed Air Temp Staefa

535-493

Outside Air Damper 2 position spring return

Siemens

GCA-121-1U

Damper operation by BAS DX control by internal unit controls.

Discharge reset signal by BAS.

Locate pressure tap in supply duct adjacent to unitary pressure tap.

Setra

2641-2R5WD-11-A1-E

Differential Pressure Transducer

POWERS

L H

Compressor 1 Status Veris H900

Current Switch

Compressor 2 Status Veris H900

Current Switch

Unitary contacts

Filter Status

VARIABLE AIR VOLUME, SELF-CONTAINED, WATER COOLED AIR CONDITIONING UNIT WITH FREE COOLING (AC – 1, 2, 4, AND 6)

System Description: Variable air volume, self-contained, water cooled air conditioning unit with water-side economizer coil. Interface with BAS will provide scheduled (day/night) operation. Because the building is heated with waste heat from the computer room night set back is not required.

Sequence:

Unoccupied: Unit fan is off. Outside air damper closes any time the fan stops.

Occupied: Unit fan runs continuous, outside air damper opens, via BAS outputs. Stop fan on smoke detection in unit discharge duct.

Factory furnished controls include the following:

1. Static pressure control. High side static pressure sensor to be located in the medium pressure duct system at approximately two thirds the longest run of the system. This pressure probe provides static pressure input to a factory mounted controller in the unit to position inlet vanes on the supply air fan.

2. Discharge air temperature (DAT) control. A temperature sensor in the fan discharge is input to a factory mounted controller that sequences compressors, steps of unloading and hot gases bypass as required to provide constant discharge air temperature. DAT will be reset based on average VAV/FTU zone load. DAT will follow Reset Schedule DAT-1.

3. Water-side economizer cycle. An inlet water sensor acting thru a factory mounted controller sequences a two position three way control valve to divert the inlet water thru the water-side economizer coil when the inlet water temperature falls below 70 degrees. A unit mounted water regulating valve controlled by refrigerant circuit head pressure modulates the water flow thru the heat exchanger.

4. Minimum outside air damper control. Two position outside damper will be opened during normal occupied operation, to provide fresh air. The outside air damper will close during unoccupied operation, and during occupied operation when carbon monoxide (CO), or volatile organic compounds (VOCs), exceed acceptable levels. The damper will remain closed, for a time based on the severity of how far the acceptable level set point had been exceeded.

BAS will monitor, duct static pressure, discharge air temperature, return air temperature, mixed air temperature, mixed air humidity, mixed air CO2, mixed air CO, mixed air VOC, Compressor status, fan status, and filter status.

Nose 5 Monitor

Nose 5 monitor to sense mixed air temp, relative humidity (RH), carbon dioxide (CO2), carbon monoxide (CO), and volative organic componds (VOCs).

50 deg F

70 deg F

Reset Schedule DAT-1

0% 100% Average VAV/FTU Cooling Load

Discharge Air Setpoint

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

DI Source Signal + Common -

Lon Network

IN1

DI Source Signal + Common -

IN2

DI Source Signal + Common -

IN3

DI Source Signal + Common -

IN4

DI Source Signal + Common -

IN5

DI Source Signal + Common -

IN6

Common Signal Out

OUTA1

Common Signal Out

OUTA2

Common Signal Out

OUTA3

24VAC

Triac Sw

OUTD1

24VAC

Triac Sw

OUTD2

24VAC

Triac Sw

OUTD3

24VAC

Triac Sw

OUTD4

24VAC

Triac Sw

OUTD5

24VAC

Triac Sw

OUTD6

24VAC

Triac Sw

OUTD7

4224VAC

Triac Sw

OUTD8

H N E

Controller E-123-7 587-292 Staefa Four Loop panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

Notes:

1. Predator common terminals are internally connected to neutral.

2. Terminal blocks have the panel letter designation before the terminal number on each block.

3. Tie Start Stop contacts to AHU, note terminal block and terminals on

AS BUILT DRAWINGS.

4. Install Hawkeye current switch around one phase conductor of the main fan power circuit, after the fan contactor.

5. Install Hawkeye current switch around one phase conductor of the respective compressor that is being monitored. Compressor #2 will be run to AHU 5 controller.

6. Install Nose monitor in aspirator enclosure, in mixed air section of AHU. Monitor will control OA damper of both AHU #6 and AHU #8.

E-TB1

T1 - 24V AC Line T1 - 24V AC Neutral T1 - Ground

Mechanical Room Panel 123-E AHU 6 Wiring

M ec ha ni ca l R oo m

P an el

-E

A H

U

W iri ng

Max. Total Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable†

Discharge Air Temperature Sensor

GR

PSH75A

120V/24V - 75 VA

Transformer

T1 T1 - 24V AC Line T1 - 24V AC Neutralblue yellow

T1 - Groundgn

120V AC Line 120V AC Neutral Ground

TB2

120 VAC

PSM - 24 VDC --

PSM

Note : Bond Neutral and Ground to earth ground, on secondary of T1. Also tie 24 VDC -- to earth ground on PSM.

PSM - 24 VDC +

Enclosure E Power Supply Detail

ST-D24-XH Duct Sensor10K OHM

ST-D24-XH Duct Sensor10K OHM

Contact provided Air Handling Unit.

RIBMN24S Panel 123 -E

T1 - 24V AC Line

T1 - 24V AC Neutral

Return Air Temperature Sensor

Fan Status Indication

Filter Status Indication

H900 Hawkeye Current Switch

Fan Start Stop

Outside Air 2 Position Damper Ventilation Air

Damper

2 GMA121.1P

1 Actuator

PSM - 24V DC "+"

36 " Duct Ave.

Sensor535-493 544-343- 100 ohm RTD + 4-20mA ohm

Mixed Air Temperature Sensor ohm

2641-2R5WD-11-A1-E

VAV Sys D. Pressure

+ Pressure

- Transducer Duct Static Pressure PSM - 24V DC "+"

RIBMN24S Panel 123 -E

To TB-OR / OR

Discharge Air Reset

H900 Hawkeye Current Switch Compressor 1 Status Indication

Room sensor cable White/orange Room sensor cable White/blue

Nose 5 Monitor Lon Lon

24 VAC

24 VAC

LonTalk TP/FT-10 LonTalk TP/FT-10

T1 - 24V AC Line T1 - 24V AC Neutral

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

New Control panel CP-323 A

2" Conduit

1" Conduit to devices

1/2" Conduit for Power

Existing High Voltage

Disconnect

Predator Controller #323 - 1

AHU 1

Predator Controller #323 - 2

AHU 2

Predator Controller #323 - 3

AHU 10

TB

-1

Mechanical Room 323 (West Fan Room) Panel Layout

CP-323 B CP-323 C

M ec ha ni ca l R oo m

(W es t F an

R oo m ) P an el

L ay ou t

TB-1(existing)

TB-2

PSM

Power Supply

Re la ys Re la ys

Functional Devices

PSH75A

Power Supply

TB-2

PSM

Power Supply Re la ys

Notes:

1. Run power to panels A & B from a dedicated branch circuit from UPS power. Max. Total

Wire Length

Max.

Node to Node Length

Max. Total Wire Length (Note 2)

Max. Node to Node Length

22 AWG Level 4 (Note 1)

1640 ft 1312 ft 4593 ft 4593 ft

Predator Controller Wiring Requirem ents:

LonWorks Network Wiring Requirem ents:

*Level IV cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

1. Level 4 cable per NEMA standards (not equivalent to EIA/TIA Level 4 cable).

Windy C ity # 105540/S = 1000 ft spool.

Notes:

18–22 AWG TP

16–20 AWG per local code and current/length voltage drop requirements

Connection Type 24 Vac input Network connection Predator Room Temperature Application Inputs Analog outputs D igital outputs

Recommendation

Wire Type and Gauge

Free Topology Bus Topology

18–22 AWG TP

32wire, 18AWG cable 22 AWG TP, Level IV* Pre-terminated, plenum-rated, 3-pair cable† panel wiring field wiring bold terminal # = common

Legend

Wire Color Convention orange -LonTalk TP/FT-10 red - 24VDC "+" black - 24VDC "-" yellow - 24VAC Line blue - 24VAC Neutral green - earth ground white - controller 1 I/O(s) gray - controller 2 I/O(s) violet - controller 3 I/O(s) brown - controller 4 I/O(s) pink - controller 5 I/O(s)

GR

PSH75A

120V/24V - 75 VA

Transformer

T1 T1 - 24V AC Line T1 - 24V AC Neutralblue yellow

T1 - Groundgn

120V AC Line 120V AC Neutral Ground

TB2

120 VAC

PSM - 24 VDC --

PSM

Note : Bond Neutral and Ground to earth ground, on secondary of T1. Also tie 24 VDC -- to earth ground on PSM.

PSM - 24 VDC +

Enclosure A & B Power Supply Detail

Existing panel - Has Existing devices from aux unit in this half of panel.

#10.

TB-1

Network Manager 587-730

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Entry Level

Upper Level

FTU 13

East Fan RoomWest Fan Room

FTU 6

FTU 7

Lon Trunk

Lon Trunk

VAV 14

FTU 14VAV 13 VAV 10 VAV 11 VAV 12

Lon Trunk

24 VAC 24 VAC

FTU 15VAV 18

24 VAC

Lon Trunk

AHU 7

Fan Room

FTU 2 FTU 1

VAV 16

FTU 8 FTU 3

VAV 6

FTU 9

VAV 5

FTU 10

VAV 4

24 VAC 24 VAC 24 VAC

Lon Trunk

VAV 1

FTU 5

VAV 2

FTU 4

VAV 3

24 VAC 24 VAC

Lon Trunk

24 VAC

Network manger 2 Lon and Power Trunk

N et w or k m an ge r 2 L on a nd P ow er

T ru nk

Network Manager

Network Manager 587-730

T T T

T

T T

VAV 15

24 VAC

CP-323-A

3 controllers

Lon Trunk

Nose-5

AHU -1

Nose-5

AHU -2

T

T T T

Lon Trunk

24 VAC

CP-323-B

VAV 21 VAV 20

T T

VAV 17

24 VAC

Lon Trunk

CP-306-A

1 controller

CP-306-B

1 controller

Nose-5

AHU -4

24 VAC

Lon Trunk

Nose-5

AHU -7

CP-LD-A

2 controllers

T T T T T TT T T T

T = Space temperature sensor attached

Lon Trunk Lon Trunk

Lon Trunk

24 VAC

T

TI

TL

E

SHEET NUMBER

JOB NUMBER

DATE

CHECKED

DRAWN

BF

TM

7/04

4645-0504

D

IT

C O

Revisions:

B U

IL

D

IN

G

C O

N

TR

O

LS

D

IV

IS

LA

C

KL

A N

D D

R

IV

E S

T.

L

O U

IS

, M

O

(3

) 9

-3

Talon Small…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.