Amendment_0003_EPA.pdf

PDF 3 MB Posted

Attached to
EPA CO Relocation and renovation of Building 25 at the Denver Federal Center
Solicitation number
GS-08P-16-JB-C-7031
Issued by

About this file

SF30 Amendment 0003

View the file

Other files

File Type Posted
Amendment_0007.pdf PDF
Amendment_0006.pdf PDF
Amendment_0005_EPA.pdf PDF
Amendment_0002_EPA.pdf PDF
Amendment_0004_EPA.pdf PDF
Amendment_0001_EPA.pdf PDF
2016-10-12_EPA_Building_Addendum_06.pdf PDF
Questions_ _Answers_4th_Set__10122016.doc DOC document
DB_Heavy_Jefferson_06032016.doc DOC document
Questions_ _Answers_3rd_Set__10072016.doc DOC document
DB_Building_Jefferson__08052016.doc DOC document
Questions_2nd_Round__10052016.doc DOC document
2016-09-30_EPA_Building_Addendum_05.pdf PDF
Storm_Water.pdf PDF
Questions_09272016.doc DOC document
2016-09-21_EPA_Building_Addendum_04.pdf PDF
Siemens_Sole_Brand_Justification.pdf PDF
SITE_VISIT_EPA_09222016.doc DOC document
SITE_VISIT_EPA_09082016.doc DOC document
Attachment_3_-_Offeror_Experience_Information_Document.doc DOC document
C301_GC_Reps_ _Certs_EPA.doc DOC document
Attachment_4_-_Offeror_Past_Performance_Survey.doc DOC document
Attachment_2_Request_for_Solicitation_Documents_Form.doc DOC document
Scope_of_Work_EPA_08242016.pdf PDF
Cover_Letter_GS-08P-16-JB-C-7031.pdf PDF
Attachment_1_SBU_Form_GS08P16JBC7031.docx DOCX document
C201_GC_Solicitation_EPA_Final.doc DOC document
GSA_527.pdf PDF
C101_GC_Agreement_EPA_Final.doc DOC document
SF1442_GS-08-P-16-JB-C-7031.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION

NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.

IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

3198 Speer Boulevard

Denver Colorado 80211

303 294 9448

Fax 303 294 0762 amd@amdarchitects.com

ADDENDUM N0. 06 - Construction Documents

Date: 12 October 2016

Project #: 2009121.11

Project: EPA Building 25 Co-Location Project

Bid Documents Issued: 100% Construction Documents dated 15 April 2016

The Drawings, Specifications, and Contract Documents on the project are modified, corrected, supplemented, and/or superseded as hereinafter described. It will be construed that each bidder’s proposal is submitted with full knowledge of all modifications and supplemental data specified herewith. This addendum may affect pricing. Failure to acknowledge this addendum may be cause for rejection of bid.

DRAWINGS:

1. A-101D

a. Added keynote #187

2. A-502

a. Revised Finished Schedule

3. M-401

a. Revised Exhaust Fan Schedule

4. P-111A

a. Revised drawing 1/P-111A

b. Revised keynotes #2 and #15

5. P-111B

a. Revised keynote #2

6. P-111C

a. Revised drawing 1/P-111C

b. Revised keynotes #2 and #27

7. P-604

a. Revised drawing 5/P-604

PROJECT MANUAL:

None

Attachments: As described above.

End of Addendum

WORK NOTES GENERAL NOTES

7. REPAIR ALL EXISTING SURFACES WHERE EXISTING MOUNTED ITEMS HAVE BEEN

REMOVED, MATCH EXISTING ADJACENT SURFACE FINISH.

8. PROVIDE BLOCKING IN WALLS FOR ALL MOUNTED ITEMS.

9. AT LOCATIONS WHERE EXISTING WALLS ARE REMOVED, REPAIR REMAINING

WALLS ADJACENT TO THE DEMO AREA, MATCH ADJACENT SURFACE FINISH.

10. COORDINATE CONSTRUCTION ACTIVITIES WITH CONTINUOUS BUILDING

OCCUPANCY. MAINTAIN REQUIRED EXIT AND LIFE SAFETY SYSTEMS. MAINTAIN

OPERATIONAL RESTROOM FACILITIES. PROVIDE TEMPORARY PARTITIONS TO

SEPARATE CONSTRUCTION ACTIVITIES FROM OCCUPIED AREAS AND EGRESS. ALLOW

FOR DELIVERIES AND EMERGENCY ACCESS.

11. PROVIDE 48" TALL POWDER-COATED STAINLESS STEEL CORNER GUARDS AT ALL

OUTSIDE GB WALL CORNERS IN THE LAB CORRIDORS.

12. INTERIOR DIMENSIONS ARE TO FINISHED FACE OF PARTITION, U.O.N.

13. ALL CHANGES IN FLOOR MATERIAL AT DOORS OCCUR AT INSIDE CORNER OF

THE STOP AT THE DOOR SIDE

1. FIELD VERIFY ALL EXISTING CONDITIONS. NOTIFY ARCHITECT PRIOR TO

START OF WORK IF ANY EXISTING CONDITIONS AFFECT ANY NEW WORK

SHOWN. THIS ALSO APPLIES TO WORK SHOWN ON STRUCTURAL,

LABORATORY, MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION

DRAWINGS.

2. ALL PARTITIONS, NEW INFILL AND EXTENSIONS AT EXISTING WALLS SHALL BE

PARTITION TYPE 'B', UON., MATCH THICKNESS OF EXISTING PARTITION AT INFILL

AND EXTENSIONS. EXTEND PARTITIONS FULL HEIGHT TO BOTTOM OF DECK

ABOVE, UON.

3. REFERENCE CODE PLANS FOR LOCATIONS OF FIRE RATED WALLS.

4. REFERENCE LABORATORY PLANS FOR LAB INFORMATION.

5. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ARCHITECT

OF ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND INFORMATION

SHOWN IN THESE DOCUMENTS PRIOR TO START OF ANY WORK.

6. AT LOCATIONS WHERE EXISTING FLOORS, WALLS, OR CEILINGS ARE OPENED

FOR NEW WORK, REPAIR TO MATCH ADJACENT CONSTRUCTION AND FINISH.

LEGEND

EXISTING WALLS

NEW DOORS

MATCHLINE

NEW PARTITIONS, COLUMN

WRAPS, AND FUR OUTS

EXISTING DOORS

PROJECT BOUNDARY

25242322212019181716

L

M

N

O

P

Q

R

SHARED

ORGANIC

INSTRUMENTS

1C-045

R8

MICROBIOLOGY

1C-085

NEIC VOA

1C-115

SHARED

SEM/TEM

1C-630

(E) NEIC AIR

TOXICS LAB

1D-525

CHILLER

1C-620

ESAT METALS

1C-120

SHARED PCR

1C-090

NEIC ORGANIC

PREP

1C-060

INERGEN

CYLINDER

ROOM

1C-145A

R8 AIR

CALIBRATION

ROOM

1C-425

NEIC DRUM

TUMBLER

1C-365

NEIC CYANIDE

& SULFIDE

1C-325

ESAT TEM

PREP

1D-520

R8 TRACE

LEVEL

ELEMENTAL

LAB

1C-150

NEIC

ELEMENTAL

ANALYSIS

1C-520

SHARED GAS

CYLINDER

STORAGE

1C-540B

SHARED

ORGANIC

STORAGE

1C-540A

GAS CLOSET

1C-515

SHARED LCs

1C-420

NEIC

INORGANIC

PREP

1C-360

R8 WET

CHEMISTRY

1C-320

NEIC LABWARE

CLEANING

1C-340B

SHARED IC /

IC-MS

1C-005

(E) NEIC TCLP

1C-305

(E) NEIC X-RAY

FLOURESCENCE

/ DIFFRACTION

1C-130

NEIC

ASBESTOS

1C-610

TRACE LEVEL

PREP

1C-180

SHARED

TRACE LEVEL

PREP

1C-170

ACID

NEUTRALIZATION

1C-535

(E) NEIC NMR

1C-405

(E) NEIC

ENVIRONMENTAL

SAMPLE

RECEIPT &

STORAGE

1C-210

R8 AIR

CALIBRATION

1C-425B

SECURITY

1C-325A

SHARED DI

1C-355

ORGANIC

STORAGE

1C-145B

GAS CLOSET

1C-410

GAS CLOSET

IC-415

GAS CLOSET

IC-315

GAS CLOSET

1C-440

GAS CLOSET

IC-310

NEIC X-RAY

1C-130A

GAS CLOSET

1D-505

GAS CLOSET

1D-515

COMPRESSOR

ROOM

1F-185

GAS CLOSET

1C-140

GAS CLOSET

1C-510

GAS CLOSET

1C-530

(E) VESTIBULE

1C-010

(E) WOMEN

1C-020

(E) MEN

1C-040

(E)

ELECTRICAL

1C-050

(E) LAN

1C-240

(E) TELECOM

1C-230

JAN.

1C-030

GAS CLOSET

1C-035

GAS CLOSET

1C-054

GAS CLOSET

1C-075

GAS CLOSET

1C-105

GAS CLOSET

1C-080

GAS CLOSET

1C-110

NEIC TRACE

LEVEL

ELEMENTAL

LAB

1C-160

C

-0

D

-5

1C-145A.1 1C-145A.2

C

-3

A

RE: 1 / A-101C

R E

A

-1 A

R E

A

-1 B

RE: 1 / A-101C

VESTIBULE

VE-06

LAB CORRIDOR

C1C5

LAB CORRIDOR

C1C4

LAB CORRIDOR

C1C0

LAB CORRIDOR

C1D5

LAB CORRIDOR

C1C6

LAB CORRIDOR

C1C1

LAB CORRIDOR

C1C3

LAB CORRIDOR

C1C2

HF-3

UP

UP

RE: 1 / A-101A

(E) UPS

1D-460

101101

101101

CORRIDOR

C1B5

CL

EQ EQ

DN

DN DN

138129129

C

C

39' - 0"

C1F1

CORRIDOR

MAIN

ELECTRICAL

1D-535

142129

C

-3

A

CC

FE(E) FE(E)

FE(E)

FE(E)

FE(E)

FE(E)

FE(E)

158158158

1C-145B

INORGANIC

STORAGE

1C-145C

C

-5

8' - 3"

DF(E)

DF(E)

R8 VOA

1C-095

(E )1

C -2

(E )1

C -3

R8 LABWARE

CLEANING

1C-340A

A-421

8' - 4 7/8" 10' - 0"

129129

C6

2' - 5"

129129

129 C6

44' - 2"

C

-2

1C-145C

169169 169 169

C

-3

51C-160.1

1C-150.1

TYP, ALL

(4) WALLS

101 101

DN

1C-160

1C-150

UP

DN

4' - 0"

V

IF

(E) WOMEN

1D-530

DN

129129

FE-1

FE(E)

FE-1

EQ EQ

FE-1

9' - 0"

FE-1

15' - 8"

FE-1

10' - 5"

FE-1 FE-1

16' - 0"

FE-1

2' - 0"

FE-1

9' - 6"

FE-1

A

A

169169

169169169

CORRIDOR

C1B5

169 169

169 169

169169169169

100' - 6"100' - 2"

(E) WOMEN

1D-540

(E) MEN

1D-550

1' - 11"

SLOPE

1:12 MIN(E) (E)

129129

129129

137 137

EQ EQ

B

-2

901 TYP, ALL

(4) WALLS1

Addendum

187 Addendum

Project Number:

Drawn By:

Reviewed By:

Approved By:

Issue Date

GENERAL SERVICES ADMINISTRATION

ROCKY MOUNTAIN REGION

MOUNTAIN PLAINS SERVICE CENTER (8PSMP)

P.O. BOX 25546

BUILDING 41

DENVER FEDERAL CENTER

DENVER, CO 80225

303-236-2854

AndersonMasonDale Architects, P.C.

3198 Speer Boulevard

Denver, CO, 80211

Telephone: 303-294-9448

FAX: 303-294-0762

Architect

Iron Horse Architects

475 17th Street, Suite 720

Denver, CO, 80202

Telephone: 720-855-7572

Laboratory Planning

Martin Martin

12499 West Colfax Avenue

Lakewood, CO, 80215

Telephone: 303-431-6100

Structural Engineering

Farnsworth Group

4755 Forge Road, Suite 150

Colorado Springs, CO, 80907

Telephone: 303-692-8838

Mechanical Engineering

MEP Engineering

6402 South Troy Circle, Suite 100

Centennial, CO, 80111-6439

Telephone: 303-936-1633

Electrical Engineering

Jensen Hughes, Inc

520 Courtney Way, Suite A

Lafayette, CO, 80026

Telephone: 303-439-0485

Fire Protection

Advanced Consulting Engineers, Inc

3900 S. Wadsworth Blvd., Suite 595

Lakewood, CO, 80235

Telephone: 720-981-4150

Code Consultant

1A

1B

1C

1D

PLAN KEY

Parametrix, Inc

7186 South Highland Drive

Salt Lake City, UT, 84121

Telephone: 801-733-5900

Cost Estimator

GSA PROJECT NO. N10565510

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Seal

Do not remove this notice.

Properly destroy or return document when no longer needed.

/1

/2

:1

:0

P M

A-101D

LEVEL 1 FLOOR PLAN - AREA 1D

2009121.11

JF

CO

DP

EPA BUILDING 25

CO-LOCATION PROJECT

DENVER FEDERAL CENTER

BUILDING 25, LAKEWOOD, CO

15 APRIL 2016100% Construction Documents

182 NEW POURED IN PLACE CONCRETE RAMP

187 ACID NEUTRALIZATION VAULT, RE: MECH

AND STRUC, PROVIDE WATERPROOFING

AT ALL SIDES AND TOP

901 PROVIDE 3-1/2" SOUND ATTENUATION

BLANKET WITHIN EXISTING STUD WALL

CAVITY

137 PREPARE EXISTING EPOXY FLOOR FOR

NEW EPOXY FLOOR INSTALLATION

138 FURR-OUT EXISTING WALL WITH METAL

FURRING, STUDS AND 5/8" GYPSUM

BOARD AS REQUIRED TO ALIGN WITH

EXISTING ADJACENT WALL (MATCH

EXISTING ADJACENT WALL FINISH)

142 CENTER DOORS BETWEEN SIDE WALLS

154 REPAIR WALL OPENING WHERE DOOR

AND DOOR FRAME WERE REMOVED

158 EXISTING CONCRETE CURB TO REMAIN

169 FIRE SEALANT AT BASE OF EXISTING

WALL, BS, FOR 1 HR RATED PARTITION,

RE: CODE PLANS; INSTALL NEW WALL

BASE AS SCHEDULED

174 RE-FRAME COLUMN SURROUND TO ALIGN

WITH EXISTING PARTITION, RE PLANS

178 SAW CUT SLAB AT DASHED LINES FOR

VIBRATION SEPARATION, RE: STRUC

101 NO ARCHITECTURAL WORK AT THIS

SPACE EXCEPT REQUIRED REPAIRS

RESULTING FROM OTHER WORK THAT

MAY BE REQUIRED AND UON

(MECHANICAL, ELECTRICAL, FIRE

PROTECTION, ETC.)

129 ALIGN

130 NEW PARTITION INFILL SIMILAR TO

PARTITION TO TYPE B - MATCH EXISTING

ADJACENT WALL THICKNESS, PAINT AND

FINISH OF ADJACENT WALL SURFACE AT

BOTH SIDES

131 LOCATE NEW PARTITION TO ALIGN WITH

EXISTING COLUMNS (GYPSUM BOARD AT

THIS SIDE OF PARTITION TO RUN

CONTINUOUS ACROSS COLUMN FACE)

132 WRAP EXISTING GYPSUM FURRED

COLUMNS WITH ONE LAYER OF 5/8" TYPE

'X' GYPSUM BOARD FULL HEIGHT

4' 16'2' 8' A-101D 1/8" = 1'-0"

1LEVEL 1 FLOOR PLAN - AREA 1D

TRUE NORTH

Addendum 01 27 MAY 2016

Addendum 02 05 AUGUST 2016

Addendum 06 12 OCT 2016

Addendum

1. REFER TO THE DOOR SCHEDULE FOR DOOR AND

DOOR FRAME FINISHES.

2. ALL ORIENTATION BASED ON PLAN NORTH

3. WHERE NEW PAINT IS SHOWN AT CEILINGS OF

ROOMS SHOWN TO BE OPEN TO STRUCTURE, PAINT

ALL EXPOSED STRUCTURE, FLOOR DECK, EXPOSED

CONDUIT AND BOXES, EXPOSED DUCTS AND

HANGERS, AND ALL OTHER UNLESS SHOWN TO

HAVE FACTORY FINISH.

4. WHERE NEW PAINT IS SHOWN AT WALLS OF ROOMS

WITHOUT CEILINGS, WALLS SHALL BE PAINTED FULL

HEIGHT.

5. REFERENCE FLOOR PLANS FOR ADDITIONAL FINISH

REQUIREMENTS.

6. MATERIAL AND FINISH TYPES WITH "-E" SUFFIX

INDICATE EXISTING MATERIAL OR FINISH TO REMAIN.

7. SEE FINISH PLANS FOR SPOT AREAS OF PAINTING.

8. INSTALL RUBBER BASE (RB-1) AT LOCATIONS WHERE

FIRE CAULKING IS INSTALLED AT EXISTING

PARTITIONS, UNO

ABBREVIATIONS GENERAL NOTESBASIS OF DESIGN FINISHES KEY TO "REMARKS"

ASD ANTISTATIC DISSIPATIVE FLOORING

CONC CONCRETE

CT-E EXISTING CERAMIC TILE

CPT CARPET

GB GYPSUM BOARD

E EXISTING

ECONC EPOXY PAINT CONCRETE

EPNT EPOXY PAINT

ES EXPOSED STRUCTURE

MAS MASONRY UNITS

NA NOT APPLICABLE

NO NONE REQUIRED

PNT PAINT

RB RUBBER BASE

RES RESINOUS FLOORING

RSF RESILIENT SHEET FLOORING

VCT VINYL COMPOSITION TILE

SC SEALER ON CONCRETE

TB TERAZZO TILE BASE

TT TERAZZO TILE

VCT VINYL COMPOSITION TILE

APC-1 MFR: Armstrong

STYLE/COLOR: Cortega Tegular 2X4 / White

REMARKS: Match existing

APC-2 MFR: Armstrong

STYLE/COLOR: Clean Room VL Square 2X4 / White

CPT-1 MFR: Milliken

STYLE COLOR: Design Rhythms / Custom

REMARKS: Match existing (owner stock provided)

RB-1MFR: Johnsonite

STYLE/COLOR: 4" H cove base / #47 Brown

REMARKS: Match existing

RB-2MFR: VPI

STYLE/COLOR: 4"H cove base / 40 Sandstone

REMARKS: Scheme 1 and 3, match existing

RB-3MFR: VPI

STYLE/COLOR: 4"H cove base / 86 Tudor Gray

REMARKS: Scheme 2, match existing

RSF-1 MFR: Nora Systems

STYLE/COLOR: Sentica 3MM / 6505 Silk

REMARKS: Scheme 1, 2 and 3

RSF-2 MFR: Nora Systems

STYLE/COLOR: Environcare 3MM / 2953 Agave

REMARKS: Scheme 1

RSF-3 MFR: Nora Systems

STYLE/COLOR: Environcare 3MM / 2936 Flax

REMARKS: Scheme 2

RSF-4 MFR: Nora Systems

STYLE/COLOR: Environcare 3MM / 2930 Wildflower

REMARKS: Scheme 3

VCT-1 MFR: Mannington

STYLE/COLOR: Essentials / 131 Oyster White

VCT-2 MFR: Mannington

STYLE/COLOR: Progressions / 55137 Sandrift

RES-1 MFR: DUR-A-FLEX

STYLE/COLOR: Dur-A-Quartz Armor Top / Q28-23

1. EXISTING CEILING TO REMAIN, REPAIR AREAS AFFECTED

BY CONSTRUCTION, MATCH FINISH AND TEXTURE OF

EXISTING CEILING

2. PATCH FLOOR TO MATCH ADJACENT MATERIAL AND

FINISH AT DOOR/WALL REMOVAL, RE: PLANS

3. LEVEL SUB FLOOR PRIOR TO INSTALLATION OF FINISH

FLOOR. MATCH HEIGHT TO EXISTING ADJACENT SUB

FLOOR, UON.

4. RESTRICT PAINTING TO AREA NOTED ON FINISH PLAN

5. PATCH AND LEVEL FLOOR AT LOCATIONS OF EWSS

REMOVAL, PRIOR TO INSTALLATION OF NEW FINISH

FLOOR; RE: DEMO DRAWINGS LOCATIONS.

6. GSA TO PROVIDE ATTIC STOCK OF CPT-1 FOR

CONTRACTOR TO INSTALL

DOOR TYPE SCHEDULE

WD-2WD-3WD-4

WD-6 WD-5

6" 6"RE: SCHRE: SCH 6" 6"

6" 6" 6" 6"

3' - 0"

3' - 0"

R E

S

C H

R E

S

C H

R E

S

C H

R E

S

C H

R E

S

C H

EQEQ

RE: SCH

EQEQ

RE: SCH

RE: SCH RE: SCH

R E

S

C H

WD-1

WD-4HM-4 WD-1

WD-6

HM-1

HM-6

HF-1

2" 2"

FRAME TYPE SCHEDULE

R E

S

C H

RE: SCH

GENERAL NOTES

1. FIRE RATINGS ARE IN MINUTES

2. 4'-0" WIDE OPENINGS CORRESPONDING WITH DOOR

TYPES WD-2, HM-2, WD-3 OR HM-3 HAVE 3'-0' WIDE ACTIVE

DOOR LEAF AND 1'-0" WIDE INACTIVE LEAF.

3. WOOD DOORS ARE 1 3/4" SOLID CORE WITH PLAIN SLICED

WHITE BIRCH VENEER WITH LIGHT RED STAIN (CONFIRM

VENEER TYPE AND STAIN COLOR MATCH TO EXISTING

DOORS).

4. COORDINATE UNDERCUT REQUIREMENTS WITH FLOOR

FINISHES AND DOOR BOTTOMS.

5. ALL INTERIOR GLAZING IS TEMPERED U.O.N.

6. ALL GLASS IN DOORS, SIDELITES AND OTHER LOCATIONS,

DEFINED AS HAZARDOUS PER 2015 IBC SECTION 2406.4

SHALL BE TEMPERED TO MEET THE REQUIREMENTS OF

ANSI 297.1 AND CPSC 16 CFR 1201 CATERGORY 1 AND 2.

ABBREVIATIONS

AD ALUMINUM FRAME

FG FIRE-RATED GLASS

FR FIRE-RATED ALUMINUM FRAME

HD HOLLOW METAL DOOR

HF HOLLOW METAL FRAME

MG MONOLITHIC GLASS

NA NOT APPLICABLE

NO NONE REQUIRED

PNT PAINT

STN STAIN

WD WOOD DOOR

(E) EXISTING

KEY TO "REMARKS"

1. EXISTING DOOR AND FRAME,

REPLACE OPERATING MECHANICS

2. RE-USE EXISTING DOOR FRAME

3. EXISTING DOOR AND FRAME, PREP

FOR NEW CARD READER

4. RE-USE EXISTING DOOR HARDWARE

5. RE-USE EXISTING CARD READER

GLAZING SCHEDULE

MG-1 1/4" CLEAR FLOAT GLASS

MG-2 1/2" CLEAR FLOAT GLASS

FG-45 45 MINUTE RATED CERAMIC GLASS

FG-60 60 MINUTE RATED CERAMIC GLASS

5' - 2"

HF-3

2" 2' - 4" 2"

2' - 4" 2"

7' - 2"

AFF

A-501

MG-1 MG-1

FLOOR LINE

A-501

SIM

A-501

SIM

RE: PLANS FOR PARTITION TYPE

LINE OF INTERSECTING WALL

(WHERE APPLICABLE) -

PARTITION TYPE PER PLANS

2" 2"

DOOR, RE: DOOR SCHEDULE

HM FRAME

SEALANT, BOTH SIDES

SPOT GROUT AT ANCHOR POINTS

(HEAD SIM)

/2

T

Y P

JAMB ANCHOR, GROUT SOLID

WHERE REQUIRED FOR FIRE

RATING, MINERAL WOOL

INSULATION, OTHERWISE

RE: PLANS FOR PARTITION TYPE

(HEAD SIM)

STOP AT ROOM SIDE2"

/2

T

Y P

SEALANT, BOTH SIDES

GLAZING , RE: WINDOW SCHEDULE

E Q

E Q

JAMB ANCHOR

HOLLOW METAL FRAME EQEQ

(JAMB SIM)

5/8" GYPSUM BOARD, TYP

METAL FRAMING, MATCH EXISTING

STEEL ANGLES, RE: STRUC

SHIM, AS REQUIRED

3/8" SEALANT AND BACKER ROD, BS

DOOR

HM FRAME

BY ORDER OF THE FIRE MARSHAL

MAXIMUM STORAGE

HEIGHT - 12FT

/2

T

Y P

/2

/4

/4

"1

1' - 2"

CL

Project Number:

Drawn By:

Reviewed By:

Approved By:

Issue Date

GENERAL SERVICES ADMINISTRATION

ROCKY MOUNTAIN REGION

MOUNTAIN PLAINS SERVICE CENTER (8PSMP)

P.O. BOX 25546

BUILDING 41

DENVER FEDERAL CENTER

DENVER, CO 80225

303-236-2854

AndersonMasonDale Architects, P.C.

3198 Speer Boulevard

Denver, CO, 80211

Telephone: 303-294-9448

FAX: 303-294-0762

Architect

Iron Horse Architects

475 17th Street, Suite 720

Denver, CO, 80202

Telephone: 720-855-7572

Laboratory Planning

Martin Martin

12499 West Colfax Avenue

Lakewood, CO, 80215

Telephone: 303-431-6100

Structural Engineering

Farnsworth Group

4755 Forge Road, Suite 150

Colorado Springs, CO, 80907

Telephone: 303-692-8838

Mechanical Engineering

MEP Engineering

6402 South Troy Circle, Suite 100

Centennial, CO, 80111-6439

Telephone: 303-936-1633

Electrical Engineering

Jensen Hughes, Inc

520 Courtney Way, Suite A

Lafayette, CO, 80026

Telephone: 303-439-0485

Fire Protection

Advanced Consulting Engineers, Inc

3900 S. Wadsworth Blvd., Suite 595

Lakewood, CO, 80235

Telephone: 720-981-4150

Code Consultant

Parametrix, Inc

7186 South Highland Drive

Salt Lake City, UT, 84121

Telephone: 801-733-5900

Cost Estimator

GSA PROJECT NO. N10565510

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Seal

Do not remove this notice.

Properly destroy or return document when no longer needed.

/1

/2

:1

:0

P M

A-501

SCHEDULES AND INTERIOR

OPENINGS

2009121.11

JF

CO

DP

EPA BUILDING 25

CO-LOCATION PROJECT

DENVER FEDERAL CENTER

BUILDING 25, LAKEWOOD, CO

15 APRIL 2016100% Construction Documents

ROOM FINISH SCHEDULE

NO NAME FLOORING

BASE NORTH EAST SOUTH WEST CEILING

REMARKSMTL MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH

LEVEL 1

1A-005 (E) OPEN OFFICE CPT-E RB-1 GB-E PNT-E GB-E PNT-E GB-E PNT-E GB-E PNT-E APC-E NA 1

1A-110 R8 FIELD PREP ECONC RB-1 GB PNT-2 GB PNT-2 GB PNT-2 GB PNT-2 ES NO

1A-120 ACID LIFT SC RB-3 GB PNT-1 GB PNT-1 GB PNT-1 GB PNT-1 ES NO

1A-220 R8 SUPPLIES SC RB-3 GB PNT-1 GB-E PNT-1 GB-E PNT-1 GB PNT-1 APC-1 NA

1A-231 GAS CLOSET SC RB-1 GB PNT-1 GB PNT-1 GB PNT-1 GB PNT-1 ES NO

1A-235 ESAT INSTRUMENTS RSF-1/4 RB-3 GB PNT-2 GB PNT-2 GB PNT-2 GB PNT-2 APC-1 NA

1A-245 ESAT TOXICOLOGY & GENERAL BIO RES-1 RES-1 GB EPNT-2 GB EPNT-2 GB EPNT-2 GB EPNT-2 GB EPNT-2

1A-246 GAS CLOSET SC RB-1 GB PNT-1 GB PNT-1 GB PNT-1 GB PNT-1 NO NA

1A-250 R8 CLLE RES-1 RES-1 GB PNT-2 GB PNT-2 GB PNT-2 GB-E PNT-2 APC-1 NA

1A-254 GAS CLOSET SC RB-1 GB PNT-1 GB PNT-1 GB PNT-1 GB PNT-1 NO NA

1A-255 ESAT ASBESTOS PLM RES-1 RES-1 GB EPNT-2 GB EPNT-2 GB EPNT-2 GB EPNT-2 GB EPNT-2

1A-255A ESAT ASBESTOS RES-1 RES-1 GB EPNT-2 GB EPNT-2 GB EPNT-2 GB EPNT-2 GB EPNT-2

1A-256 GAS CLOSET SC RB-1 GB PNT-1 GB PNT-1 GB PNT-1 GB PNT-1 NO NA

1A-260 R8 MACROBIOLOGY RSF-1/4 RB-3 GB PNT-2 GB PNT-2 GB PNT-2 GB PNT-2 APC-1 NA

1A-265 SHARED METAL PREP RSF-1/4 RB-3 GB PNT-2 GB PNT-2 GB PNT-2 GB PNT-2 APC-1 NA

1A-270 R8 ORGANIC PREP RSF-1/4 RB-3 GB PNT-2 GB PNT-2 GB PNT-2 GB PNT-2 APC-1 NA

1A-340 NEIC FIELD STORAGE & STAGING SC RB-1 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB PNT-2 ES NA

1A-345 CID STAGING AND STORAGE SC RB-1 GB PNT-1 GB-E PNT-1 GB-E PNT-1 GB/GB-E PNT-1 ES NA

1A-360 SAF HALL SC RB-1 GB-E PNT-1 GB PNT-1 GB PNT-1 GB/GB-E PNT-1 APC-1 NA

1B-010 (E) ATRIUM CPT-E/TT-E TB-E GB-E NO GB-E NO GB-E NO GB-E NO GB/GB-E PNT-1/NO

1B-035 MECHANICAL SC-E RB-E GB-E PNT-E GB-E PNT-E GB/GB-E PNT-1 GB-E PNT-E NO NA

1B-170 ESAT LAB SUPPLY VCT-1 RB-1 GB-E PNT-1 GB-E PNT-1 GB PNT-1 GB-E PNT-1 APC-1 NA

1B-225 R8 LAB SUPPLY VCT-1 RB-1 GB PNT-1 GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 APC-1 NA

1B-265 NEIC LAB SUPPLY VCT-1 RB-1 GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 APC-1 NA

1C-005 SHARED IC / IC-MS RSF-1/3 RB-3 GB-E PNT-2 GB/GB-E PNT-2 GB PNT-2 GB-E PNT-2 APC-1 NA

1C-045 SHARED ORGANIC INSTRUMENTS RSF-1/3 RB-3 GB PNT-2 GB/GB-E PNT-2 GB-E PNT-2 GB/GB-E PNT-2 APC-1 NA

1C-060 NEIC ORGANIC PREP RSF-1/3 RB-3 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA 1

1C-085 R8 MICROBIOLOGY RSF-1/3 RB-3 GB-E PNT-2 GB-E PNT-2 GB PNT-2 GB-E PNT-2 APC-1 NA

1C-090 SHARED PCR RES-1 RES-1 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA

1C-095 R8 VOA RSF-1/3 RB-3 GB PNT-2 GB-E PNT-2 GB PNT-2 GB-E PNT-2 APC-1 NA

1C-115 NEIC VOA RSF-1/3 RB-3 GB PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA

1C-120 ESAT METALS RSF-1/3 RB-3 GB/GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA

1C-145A INERGEN CYLINDER ROOM (E) RB-1 GB PNT-1 GB-E PNT-E GB-E PNT-E GB-E PNT-E ES NO

1C-145B ORGANIC STORAGE ECONC RB-1 GB PNT-1 GB-E PNT-1 GB PNT-1 GB-E PNT-1 NO NA

1C-145C INORGANIC STORAGE ECONC RB-1 GB-E PNT-1 GB-E PNT-1 GB PNT-1 GB-E PNT-1 NO NO

1C-150 R8 TRACE LEVEL ELEMENTAL LAB RSF-1/2 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB/APC-E PNT-2 1, 3

1C-150A VESTIBULE RSF-1 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB PNT-2 GB PNT-2

1C-160 NEIC TRACE LEVEL ELEMENTAL LAB RSF-1/2 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB/APC-1 PNT-2 1

1C-160A VESTIBULE RSF-1 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB PNT-2 GB PNT-2

1C-170 SHARED TRACE LEVEL PREP RSF-1 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-E NA 1

1C-180 TRACE LEVEL PREP RSF-1 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-E NA 1

1C-225A SHARED HAZARDOUS SAMPLES RECEIPT & STORAGE RES-1 RES-1 GB-E PNT-2 GB PNT-2 GB-E PNT-2 GB-E PNT-2 APC-E NA 1

1C-225B R8 SAMPLE RECEIVING & STORAGE RES-1 RES-1 GB-E PNT-2 GB-E PNT-2 GB/GB-E PNT-2 GB PNT-2 APC-1 NA

1C-320 R8 WET CHEMISTRY RSF-1/2 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA

1C-325 NEIC CYANIDE & SULFIDE RSF-1/2 RB-2 GB-E PNT-2 GB/GB-E PNT-2 GB/GB-E PNT-2 GB/GB-E PNT-2 APC-1 NA

1C-325A SECURITY SC-E RB-1 GB PNT-1 GB PNT-1 GB-E PNT-1 GB-E PNT-1 ES NO

1C-340A R8 LABWARE CLEANING RES-1 RES-1 GB-E EPNT-2 GB-E EPNT-2 GB-E EPNT-2 GB/GB-E EPNT-2 GB EPNT-2

1C-340B NEIC LABWARE CLEANING RES-1 RES-1 GB-E EPNT-2 GB-E EPNT-2 GB-E EPNT-2 GB-E EPNT-2 GB EPNT-2

1C-360 NEIC INORGANIC PREP RSF-1/2 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA

1C-365 NEIC DRUM TUMBLER RES-1 RES-1 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA

1C-420 SHARED LCs RSF-1/2 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB/GB-E PNT-2 APC-1 NA

1C-425 R8 AIR CALIBRATION ROOM RSF-1/2 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB PNT-2 APC-1 NA

1C-425B R8 AIR CALIBRATION RSF-1 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB PNT-2

1C-515 GAS CLOSET SC RB-1 GB PNT-1 GB PNT-1 GB PNT-1 GB-E PNT-1 ES NO

1C-520 NEIC ELEMENTAL ANALYSIS RSF-1/2 RB-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 APC-1 NA

1C-610 NEIC ASBESTOS VCT-E RB-E GB-E PNT-E GB-E PNT-E GB-E PNT-2 GB-E PNT-E ES-E PNT-2

1C-620 CHILLER SC RB-1 GB-E PNT-1 GB/GB-E PNT-1 GB/GB-E PNT-1 GB-E PNT-1 GB PNT-1

1C-630 SHARED SEM/TEM ASD-E RB-E GB/GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB/GB-E PNT-2 APC-2 NA

1D-520 ESAT TEM PREP RSF-1/3 RB-3 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB-E PNT-2 GB PNT-2

1D-525 (E) NEIC AIR TOXICS LAB VCT-E RB-E GB/GB-E PNT-E/PNT-2 GB-E PNT-E GB/GB-E PNT-E/PNT-2 GB-E PNT-E APC-E NA

1D-530 (E) WOMEN (E) (E) GB-E CT-E/PNT-1 GB CT-E/PNT-1 GB-E CT-E/PNT-1 GB-E CT-E/PNT-1 GB-E PNT-1

1F-185 COMPRESSOR ROOM SC-E RB-1 GB PNT-1 GB PNT-1 GB PNT-1 GB PNT-1 ES NO

C1A0 CORRIDOR CPT-1/CPT-E RB-1/RB-E GB-E PNT-1 GB/GB-E PNT-1 GB-E PNT-1 GB/GB-E PNT-1 GB/APC-1 PNT-1/NA 6

C1A1 SERVICE CORRIDOR SC-E RB-1 GB-E PNT-1 NA NA GB PNT-1 GB PNT-1 ES-E NO

C1A2 LAB CORRIDOR VCT-1/2 RB-1 GB PNT-1 GB PNT-1 GB PNT-1 GB PNT-1 APC-1/GB NA/PNT-1

C1A3 SERVICE HALL SC-E RB-E GB-E PNT-1 GB/GB-E PNT-1 NA NA GB-E PNT-1 ES-E NO

C1A4 SERVICE CORRIDOR SC-E RB-1 GB-E PNT-1 GB-E PNT-1 GB PNT-1 GB PNT-1 ES-E NO

C1A5 LAB CORRIDOR VCT-1/2 RB-1/RB-E GB PNT-1 GB-E PNT-1 GB-E PNT-1 GB PNT-1 APC-1 NA

C1B5 CORRIDOR CPT-E RB-1 NA NA GB-E PNT-E GB-E PNT-1 GB/GB-E PNT-1 APC-E NA 1

C1C0 LAB CORRIDOR VCT-1/2 RB-1 NA NA GB-E PNT-1 NA NA GB/GB-E PNT-1 APC-1 NA 5

C1C1 LAB CORRIDOR VCT-1/2 RB-1 GB-E PNT-1 NA NA GB-E PNT-1 GB PNT-1 APC-1 NA 5

C1C2 LAB CORRIDOR VCT-1/2 RB-1 GB/GB-E PNT-1 NA NA GB-E PNT-1 GB-E PNT-1 APC-1 NA

C1C3 LAB CORRIDOR VCT-1/2 RB-1 GB/GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 GB PNT-1 APC-1 NA 5

C1C4 LAB CORRIDOR VCT-1/2 RB-1 NA NA GB/GB-E PNT-1 NA NA GB/GB-E PNT-1 APC-1 NA 5

C1C5 LAB CORRIDOR VCT-1/2 RB-1 GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 NA NA APC-1 NA 5

C1C6 LAB CORRIDOR VCT-1/2 RB-1 GB-E PNT-1 NA NA GB-E PNT-1 GB-E PNT-1 APC-1 NA 5

C1D5 LAB CORRIDOR VCT-1/2 RB-1 NA NA GB/GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 APC-1 NA

VE-06 VESTIBULE VCT-1/2 RB-1 GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 GB-E PNT-1

LEVEL 2

2B-030 (E) OFFICE (E) RB-1 GB-E PNT-E GB/GB-E PNT-E GB-E PNT-E GB/GB-E PNT-1 APC-E NA

2B-125 (E) OFFICE CPT-E RB-1 GB-E PNT-1 GB-E PNT-1 GB PNT-1 GB-E PNT-1 APC-1 NA

2B-135 (E) OFFICE CPT-1 RB-1 GB PNT GB-E PNT-1 GB-E PNT-1 GB-E PNT-1 APC-E NA 1, 6

2C-110 (E) TELE VCT-E RB-1/RB-E GB-E PNT-1 GB/GB-E PNT-1 GB-E PNT-1 GB/GB-E PNT-1 ES-E NO

2C-120 (E) LAN VCT-E RB-1/RB-E GB-E PNT-1 GB/GB-E PNT-1 GB-E PNT-1 GB/GB-E PNT-1 ES-E NO

C2B0 CORRIDOR CPT-E RB-1/RB-E GB-E PNT-E NA NA GB-E PNT-E GB PNT-1 APC-E NA 1

C2B1 CORRIDOR CPT-E RB-1/RB-E NA NA GB-E PNT-E GB PNT-1 GB-E PNT-E APC-E NA 1

DOOR NO

OPENING SIZE DOOR

TYPE

DOOR

FINISH

FRAME

TYPE

FRAME

FINISH HEAD JAMB FIRE RAT'G GLASS TYPE HDW

ACCESS

CONTROL REMARKSWIDTH HEIGHT

LEVEL 1

(E)1B-275 3' - 0" 7' - 0" (E) (E) (E) (E) (E) (E) 1.06 YES 3

(E)1C-210 4' - 0" 7' - 0" (E) (E) (E) (E) (E) (E) 22 YES 1

(E)1C-225A 6' - 0" 7' - 0" (E) (E) (E) (E) (E) (E) 22 YES 1

(E)1C-225B 4' - 0" 7' - 0" (E) (E) (E) (E) (E) (E) 22 YES 1

(E)1C-305 4' - 0" 7' - 0" (E) (E) (E) (E) (E) (E) 22 YES 1

1A-110 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 07 YES

1A-120 6' - 0" 7' - 0" WD-5 STN HF-1 PNT 1/A501 NA 17

1A-220 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 07 YES

1A-231 5' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 10

1A-235 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1A-245 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1A-246 5' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 10

1A-250 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1A-254 5' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 10.01

1A-255 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1A-255A 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01

1A-256.1 5' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 10.02

1A-256.2 5' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 10.03

1A-260 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1A-265 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1A-270 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1A-340 6' - 0" 7' - 0" HM-6 PNT HF-1 PNT 1/A501 MG-1 01.02 YES

1A-345 4' - 0" 7' - 0" HM-4 PNT HF-1 PNT 1/A501 MG-1 12 YES

1A-360 3' - 0" 7' - 0" HM-1 PNT HF-1 PNT 1/A501 NA 03.01 YES

1B-215 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 YES 5

1C-005 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.01 YES

1C-145A.1 4' - 0" 7' - 0" WD-1 STN HF-1 PNT 1/A501 45 NA 03

1C-145A.2 4' - 0" 7' - 0" WD-1 STN HF-1 PNT 1/A501 45 NA 04 YES

1C-145B 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 02

1C-145C 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 45 FG-45 02.01 YES

1C-150 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.04 YES

1C-150.1 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01

1C-160 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01.04 YES

1C-160.1 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 MG-1 01

1C-225A.1 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A502 MG-1 13.01 YES

1C-230 3' - 6" 7' - 0" WD-1 STN (E) PNT 1/A501 45 NA 06.01 YES 5

1C-325A 3' - 0" 7' - 0" WD-1 STN HF-1 PNT 1/A501 NA 03.02 YES

1C-340A 6' - 0" 8' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 01.01A YES

1C-355 3' - 0" 7' - 0" WD-2 STN (E) (E) (E) 45 FG-45 23 YES 2, 4

1C-515 3' - 0" 7' - 0" WD-2 STN HF-1 PNT 1/A501 MG-1 14

1D-520 4' - 0" 7' - 0" WD-4 STN HF-1 PNT 1/A501 NA 02.01 YES

C1A1 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 18

C1A2 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 19.01 YES

C1A5 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 19.01 YES

C1A6 6' - 0" 7' - 0" WD-6 STN HF-1 PNT 1/A501 MG-1 19.02

ST-01.1 3' - 0" 7' - 0" WD-1 STN (E) PNT NA 60 NA 20 2

ST-02.1 3' - 0" 7' - 0" WD-1 STN (E) PNT NA 60 NA 20 2

LEVEL 2

(E)2B-505 3' - 0" 7' - 0" (E) (E) (E) (E) (E) (E) 04.02 YES 3

2C-110 3' - 0" 7' - 0" WD-1 STN HF-1 PNT 1/A501 45 NA 03.02A YES

2C-120 3' - 0" 7' - 0" WD-1 STN HF-1 PNT 1/A501 45 NA 03.02A YES

C2B0 3' - 0" 7' - 0" WD-2 STN HF-1 PNT 1/A501 MG-1 03.02B YES

C2B1 3' - 0" 7' - 0" WD-2 STN HF-1 PNT 1/A501 MG-1 03.02B YES

ST-01.2 6' - 0" 7' - 0" WD-5 STN (E) PNT NA NA 21 2

ST-02.2 3' - 0" 7' - 0" WD-1 STN (E) PNT NA NA 20 2

DOOR SCHEDULE

2" 8"1" 4" A-501 3" = 1'-0"

1HM DOOR JAMB

2" 8"1" 4" A-501 3" = 1'-0"

3HM WINDOW JAMB

2" 8"1" 4" A-501 3" = 1'-0"

2SECTION DETAIL - HEAD @ MASONRY

2" 8"1" 4" A-501 3" = 1'-0"

4SIGN TYPE - A

Addendum 01 27 MAY 2016

Addendum 06 12 OCT 2016

Addendum

Addendum

Addendum

Addendum

Addendum

EXHAUST FAN SCHEDULE

MARK

NEW/

EXISITNG

MANUFACTURER MODEL TYPE DRIVE SERVICE CFM ESP

(IN. W.C.)

TOTAL

FLOW

CFM

PLUME

HEIGHT

(FT)

FAN

RPM

TIP

SPEED

(FPM)

NOZZLE/

OUTLET

VELOCITY

(FPM)

SOUND

ROOF OPENING MOTOR ELECTRICAL DATA PHYSICAL DATA

REMARKS

L (IN.) W (IN.) BHP RPM

HP/

WATTS

V/PH BRANCH L

(IN.)

W

(IN.)

H

(IN.)

WT.

(LBS.)

EF-1201A,B NEW MK PLASTICS AXIJET-FSW 3000 ROOF STACK EXH BELT 1200 LAB EXH 12,700 4.0 22,665 29 1491 11,710 5226 92 LwA N/A N/A 13.8 1800 20 480/3 EMERG. 77 58 163 1375 1,2,3,9,12,13,14

EF-1201C,D NEW MK PLASTICS AXIJET-F 1225 ROOF STACK EXH DIRECT 1A-260A HOOD 1500 5.2 2,803 9 3660 11,977 3846 94 LwA N/A N/A 2.31 3500 3 480/3 EMERG. 38.5 24 103 236 1,2,4,9,12,13,14

EF-1303 EXISTING MK PLASTICS AXIJET-S 1825 ROOF STACK EXH BELT 1300 SOLVENT STOR 2500 1.5 5,750 19.9 1390 6555 3012 76 LwA N/A N/A 0.97 1750 1.5 480/3 EMERG. 49 36 77 662 1,2,5,13

EF-2401A,B,C EXISTING MK PLASTICS AXIJET 3650 ROOF STACK EXH BELT 1300 LAB EXH 18,600 4 30,000 52 1163 11,122 4845 93 LwA N/A N/A 20.2 1750 20 480/3 EMERG. 81 70 155 2640 1,2,7,9,10,13

EF-2402A,B,C EXISTING MK PLASTICS AXIJET 3650 ROOF STACK EXH BELT 1300 LAB EXH 18,600 4 30,000 52 1163 11,122 4845 93 LwA N/A N/A 20.2 1750 20 480/3 EMERG. 81 70 155 2640 1,2,7,9,10,13

EF-2412A,B EXISTING MK PLASTICS AXIJET-S 1825 ROOF STACK EXH BELT 1200 & 1300 LAB EXH 5710 4.2 13,133 37.2 3011 14,200 6880 98 LwA N/A N/A 9.33 3450 15 480/3 EMERG. 49 36 77 737 1,2,5,9,10,13

EF-GEN-1 NEW MK PLASTICS AXIJET-HTS 2700 GENSET EXH BELT EMERGENCY GENERATOR

15,660/ 15,816

0.5 27,888 39.6 1803 12,745 7961 95 LwA N/A N/A 10.4/ 13.6

1800 15 480/3 EMERG. 69 52 119 996 1,2,8,13

EF-DV NEW FANTECH DEDPV-705 INLINE DIRECT 1A-340 DRYER 173 2559 N/A N/A 72 W 120/1 NORMAL 10 1,11,13

VF-1401 NEW COOK 270SQN-B INLINE BELT 1F-185 6,000 0.3 571 N/A N/A 0.764 1725 1 480/3 EMERG. 37.5 40 40 357 1,9,10,13

NOTES:

1. ALL AIRFLOW IS AT 5518 FEET ELEVATION 8. AIRFLOW AND BHP ARE HOT/COLD AIRSTREAM VALUES

2. PLUME HEIGHT EXCLUDES STACK EXTENSIONS. 9. NEW VFD WITH BYPASS, INTEGRAL DISCONNECT, AND BACNET COMMUNICATION

3. STACK DISCHARGE AT 15' ABOVE ROOF 10. NEW VFD RATED MOTOR

4. AMCA TYPE A - SPARK RESISTANT, STACK DISCHARGE AT 19' ABOVE ROOF 11. LED INDICATOR, METAL EPOXY COATED DISCHARGE HOOD WITH BACKDRAFT DAMPER (COLOR BY ARCH.), DUCT CLAMPS, DUCT PRESSURE SENSOR

5. REBALANCED EXISTING FAN 12. PROVIDE SUPPORT RING ON STACK WITH GUY WIRES TO ROOF ANCHOR POINTS. REFER TO STRUCT AND ARCH.

6. RELOCATED EXISTING FAN 13. EMERGENCY POWER

7. REBALANCED EXISTING FAN WITH NEW MOTOR, 1388 MAX FAN RPM 14. CURB RAILS FOR FAN SUPPORT SHALL BE MINIMUM 14" HIGH

PUMP SCHEDULE

MARK MANUFACTURER MODEL SIZE LOCATION SERVICE TYPE FLOW

(GPM)

HEAD

(FT)

FLUID

OPER.

TEMP.

(DEG F)

MOTOR ELECTRICAL

WT.

(LB.)

REMARKS

HP RPM V/PH FLA MCA

CP-1201 BELL & GOSSETT SERIES 60 612 AHU-1201 HEATING COIL CIRC INLINE 78.3 25 130 1.0 1750 480/3

NOTES:

AIR DEVICE SCHEDULE

TAG SERVICE MFR. MODEL FRAME MATERIAL FINISH FACE SIZE

(IN)

NOMINAL

DUCT SIZE

(IN)

REMARKS

SD-1 SUPPLY TITUS TDC TYPE 3 STEEL WHITE 24X24 SEE DWG

SD-2 SUPPLY TITUS TDC TYPE 1 STEEL WHITE 24X24 SEE DWG

SD-3 SUPPLY TITUS TRITEC TYPE 3 STEEL WHITE SEE DWG SEE DWG 24X24 OR 24X48 FACE

SD-4 SUPPLY TITUS TMRA NA STEEL WHITE SEE DWG SEE DWG

SD-5 SUPPLY TITUS TDC-FR TYPE 1 STEEL WHITE 24X24 SEE DWG 3 HR RATED SQUARE NECK

SD-6 SUPPLY FLANDERS TH54 TYPE 3 ALUMINUM WHITE 24X24 SEE DWG FLANDERS MODEL TH54-E0491

SD-7 SUPPLY FLANDERS TH54 TYPE 1 ALUMINUM WHITE 24X24 SEE DWG FLANDERS MODEL TH54-E0491

SD-8 SUPPLY TITUS TMRA NA STEEL WHITE SEE DWG SEE DWG

SD-9 SUPPLY TITUS TDC TYPE 3 STEEL WHITE 24X24 SEE DWG

SD-10 SUPPLY NAILOR 48LL1 TYPE 1 ALUMINUM WHITE 48" LINEAR SEE DWG

SD-11 SUPPLY TITUS 300RS TYPE 1 STEEL WHITE SEE DWG SEE DWG PROVIDE WITH OPPOSED BLADE DAMPER

SD-12 SUPPLY METALAIRE HRD-CL BORDER 6 SS WHITE 12X48 8

SR-1 SUPPLY TITUS 300RL-HD TYPE 1 STEEL STD. SEE DWG SEE DWG REGISTER

RG-1 RETURN TITUS PAR TYPE 1 & 3 STEEL STD. 24X24 SEE DWG

RG-2 RETURN TITUS 350FS TYPE 1 STEEL STD. SEE DWG SEE DWG

RG-3 RETURN TITUS 33RL TYPE 1 STEEL STD. SEE DWG SEE DWG HEAVY DUTY GYM TYPE

RG-4 RETURN TITUS PAR TYPE 1 & 3 STEEL STD. 24X24 22X22

TG-1 TRANSFER TITUS PAR TYPE 3 STEEL STD. 24X24 22X22

TG-2 TRANSFER TITUS PAR TYPE 1 STEEL STD. 16X16 14X14

EG-1 EXHAUST TITUS PAR TYPE 1 STEEL STD. 12X12 SEE DWG

EG-2 EXHAUST TITUS PAR TYPE 1 STEEL STD. 16X16 14X14

EG-3 EXHAUST TITUS 350FS TYPE 1 ALUMINUM STD. SEE DWG SEE DWG FOR SHOWERS AND OTHER WET AREAS

EG-4 EXHAUST NAILOR 71 DH TYPE 1 ALUMINUM ANODIZED SEE DWG SEE DWG COLOR BY ARCH., INSECT SCREEN

EG-5 EXHAUST TITUS PAR TYPE 1 & 3 STEEL STD. 24X24 22X22

EG-6 EXHAUST TITUS PAR TYPE 1 & 3 STEEL STD. 24X24 SEE DWG

EG-7 EXHAUST TITUS PAR TYPE 1 & 3 STEEL STD. 12X12 SEE DWG

NOTES:

1. TYPE 1 - SURFACE MOUNT 2. TYPE 3 - LAY IN CEILING 3. NOT ALL TYPES USED 4. BORDER 6 - LAY IN CEILING

AIR TERMINAL UNITS

TAG MFR. MODEL

ASSOCIATED

AHU

AREA

SERVED

MAX COOL

& HEAT

CFM

MIN COOL

& HEAT

CFM

HEATING COIL

REMARKSSEN. CAP

(MBH)

EAT

(°F)

LAT

(°F)

EWT

(°F)

LWT

(°F)

ROWS

PD

(FT WC)

GPM

ATU-1 TITUS DESV-14 AHU-1201 A 2,130 330 57.28 55 85 130 110 2 3.95 8.00

NOTES

FAN COIL UNITS

TAG MANUFACTURER MODEL

AREA

SERVED

UNIT TYPE

FAN COOLING COIL ELECTRICAL

WEIGHT

(LBS.)

REMARKS

CFM

MIN

CFM

ESP

(IN. WC)

TSP

(IN. WC)

BHP HP SEN. CAP

(MBH)

FACE

VEL

(FPM)

EAT

DB

(°F)

EAT

WB

(°F)

EWT

(°F)

ROWS

PD

(FT

WC)

GPM VOLT/PH MCA FLA

FCU-1 TRANE BCHD024

1A-270, 1C-320, CH CLOSETS

HORIZ CONCEALED 800 0 0.5 0.9 0.2 1/2 12.9 480.0 72 58 45 4-HC 1.2 2.8 277/1 4.7 3.8 126 1,2,3,4,5,6,7,8,9

FCU-2 TRANE BCHD036 1C-005, 1C-630 HORIZ CONCEALED 1,200 0 0.5 0.8 0.3 1/2 17.6 430.0 72 58 45 4-HC 1.4 2.7 277/1 4.7 3.8 151 1,2,3,4,5,6,7,8,9

FCU-3 TRANE BCHD054 1C-095 HORIZ CONCEALED 1,800 0 0.5 0.9 0.5 1 27.4 465.0 72 58 45 4-HC 1.1 5.8 277/1 8.4 6.7 212 1,2,3,4,5,6,7,8,9

FCU-4 TRANE BCHD072

1C-120, CH CLOSET

HORIZ CONCEALED 2,300 0 0.5 0.9 0.7 1 34.4 460.0 72 58 45 4 1.2 8.5 277/1 8.4 6.7 219 1,2,3,4,5,6,7,8,9

FCU-5 TRANE BCHD072 1C-340 HORIZ CONCEALED 2,500 0 0.5 0.9 0.8 1 38.3 500.0 72 58 45 4 1.2 8.5 277/1 8.4 6.7 219 1,2,3,4,5,6,7,8,9

FCU-6 TRANE BCHD090 1C-420 (2 FCUs) HORIZ CONCEALED 2,800 0 0.5 0.8 0.9 1 41.4 420.0 72 58 45 4 1.0 10.2 277/1 8.4 6.7 259 1,2,3,4,5,6,7,8,9

FCU-7 MULTIAQUA MHCFC4W-08-1

1C-150, 1C-160, 1C-520 CASSETTE 550 0 0.0 - 130 W - 17.4 80 67 45 4 7.2 8.5 208 1.0 0.65 71 1,2,3,4,5,6,8,9

BCU-1404 TRANE BCHD090 1F-185 HORIZ 3,500 0 0.25 1.144 1.569 1-1/2 93.5 560.0 80 67 45 6 6.63 15.78 480/3 4.13 3.30 339.8 1,2,3,4,5,6,7,8,9

NOTES:

1. SITE ELVATION = 5,518' ASL 5. PROVIDE WITH BACNET COMMUNICATION INTERFACE 9. PROVIDE MINIMUM MERV 8 FILTERS

2. PROVIDE WITH AUXILLARY DRAIN PAN 6. PREMIUM EFFICIENCY ECM DIRECT DRIVE MOTOR

3. PROVIDE UNIT WITH CONDENSATE OVERFLOW SWITCH (DRAIN PAN) 7. PROVIDE WITH RUBBER IN SHEAR VIBRATION ISOLATORS AND MOUNTING PACKAGE TO SUSPEND FROM STRUCTURE ABOVE

4. PROVIDE PRESSURE-TEMPERATURE PORTS AND AIR VENT ON COIL 8. EMERGENCY POWER

ELECTRIC HEATING COILS

TAG MFR. MODEL

NOMINAL

DUCT

DIMENSIONS

(IN.)

AREA

SERVED

CFM SEN. CAP

(MBH)

EAT

(°F)

LAT

(°F)

TOTAL

HEATER

POWER

(kW)

STAGES ELECTRICAL REMARKS

EHC-1 GREENHECK IDHB 24WX18H 1C-360 1,850 49.75 55 85 15 1 480V/3Ø/60 1

NOTES:

1. MUST MAINTAIN 1200 CFM ACROSS COIL WITH HEATER ON.

CABINET UNIT HEATERS

TAG MANUFACTURER MODEL

AREA

SERVED

FAN HEATING COIL ELECTRICAL

FILTER

SHIPPING

WEIGHT

(LBS.)

REMARKS

CFM

MIN

CFM

ESP

(IN. WC)

BHP HP TOT. CAP

(MBH)

EAT

(°F)

LAT

(°F)

EWT

(°F)

ROWS

PD

(FT WC)

GPM VOLT/PH MCA MOP FLA

CUH-5 ZEHNDER RITTLING FW-270-06 ST-02 220 0 0.00 0.02 1/25 12.8 50.0 115.3 130 2 1.5 3.0 120/1 0.9 15A 0.68 1"

THROW

AWAY

125 1

NOTES:

1. SITE ELEVATION = 5,518' ASL

AIR HANDLER SCHEDULE

MARK

NEW OR

EXISTING

MANUFACTURER MODEL LOCATION SERVICE

SUPPLY FAN EXHAUST FAN HEATING COIL COOLING COIL FILTER PHYSICAL DATA

REMARKS

MAX CFM

(FUTURE)

MAX CFM

(CURRENT)

% SPARE

CAPACITY

MIN

CFM

MIN.

OA

CFM

TSP

(IN.

W.C.)

ESP

(IN.

W.C.)

V/PH HP BHP RPM CFM

(FUTURE)

CFM

(CURRENT)

TSP

(IN.

W.C.)

ESP

(IN.

W.C.)

V/PH HP RPM

MAX.

AIR P.D.

(IN. W.C.)

TOTAL

CAP.

(MBH)

HEATING

CFM

FLOW

(GPM)

MAX.

FLUID P.D.

(FT. W.C.)

EWT

(DEG

F)

EAT

(DEG

F)

LAT

(DEG

F)

MAX.

FACE VEL.

(FPM)

MAX.

AIR P.D.

(IN. W.C.)

TOTAL

CAP.

(MBH)

SENS.

CAP.

(MBH)

FLOW

(GPM)

ROWS

MAX.

FLUID P.D.

(FT. W.C.)

EWT

(°F)

EDB

(°F)

EWB

(°F)

LDB

(°F)

LWB

(°F)

PRE FINAL

L

(IN.)

W

(IN.)

H

(IN.)

WT.

(LB.)TYPE MERV TYPE MERV

RTU-1101 EXISTING TRANE TSCX-17 ROOF-A GARAGE 7,500 7,500 0% 3,750 3,750 2.81 1.5 460/3 7.5 6.6 1856 N/A - - - - - - 0.182 669.7 7,500 46 0.9 130 -20 80 447 0.24 257 257.00 54.99 6 6.83 45 93 61 55 47.2 PANEL 8 BAG 14 184 80 54.5 4166 2,3

AHU-1201 EXISTING TRANE MCC-50 1B-035 1ST FL A 25,510 24,060 6% 3,510 3,510 4.1 3.0 460/3 25 - 1383 25510 0.75 0.75 460/3 7.5 322 0.087 781.2 24,060 78 1.19 130 35 71.4 487 0.249 689 689 98.2 - 7.34 45 86 61 55 49 PANEL 8 BAG 14 - - - - 1,3,4

RTU-1301 EXISTING TRANE TSCX-35 ROOF-C 1ST FL D LABS 17,750 14,595 18% 7,785 7,785 4.9 2.25 460/3 25 19.3 1812 N/A - - - - - - 0.21 1293.8 17,750 85 2.38 130 -10 71.6 520 0.356 639.7 639.7 100.4 6 11.08 45 95 61 55 46.4 PANEL 8 BAG 14 243 100 68 7581 1,3

RTU-1302 EXISTING TRANE TSCX-35 ROOF-C 1ST FL D LABS 17,750 17,110 4% 9,460 9,460 4.9 2.25 460/3 25 19.3 1812 N/A - - - - - - 0.21 1293.8 17,750 85 2.38 130 -10 71.6 520 0.356 639.7 639.7 100.4 6 11.08 45 95 61 55 46.4 PANEL 8 BAG 14 243 100 68 7581 1,3

RTU-1303 EXISTING TRANE TSCX-35 ROOF-C 1ST FL D LABS 17,750 12,800 28% 5,985 5,985 4.9 2.25 460/3 25 19.3 1812 N/A - - - - - - 0.21 1293.8 17,750 85 2.38 130 -10 71.6 520 0.356 639.7 639.7 100.4 6 11.08 45 95 61 55 46.4 PANEL 8 BAG 14 243 100 68 7581 1,3

RTU-1304 EXISTING TRANE TSCX-35 ROOF-C 1ST FL D LABS 17,750 15,230 14% 6,710 6,710 4.9 2.25 460/3 25 19.3 1812 N/A - - - - - - 0.21 1293.8 17,750 85 2.38 130 -10 71.6 520 0.356 639.7 639.7 100.4 6 11.08 45 95 61 55 46.4 PANEL 8 BAG 14 243 100 68 7581 1,3

RTU-1305 EXISTING TRANE TSCX-35 ROOF-C 1ST FL D LABS 17,750 16,810 5% 8,385 8,385 4.9 2.25 460/3 25 19.3 1812 N/A - - - - - - 0.21 1293.8 17,750 85 2.38 130 -10 71.6 520 0.356 639.7 639.7 100.4 6 11.08 45 95 61 55 46.4 PANEL 8 BAG 14 243 100 68 7581 1,3

NOTES: REMARKS:

1. ALL AIRFLOWS ARE AT 5518 FEET ELEVATION 1. EXISITING UNIT WITH AIR AND WATER REBALANCE

2. ALTERNATE #2 - EXISITING UNIT WITH AIR AND WATER REBALANCE AND HEATING COIL REPLACEMENT

3. EXTERNAL STATIC INCLUDES 1" FOR DIRTY FILTER LOADING

4. EXISTING UNIT WITH REPLACED HOT WATER COIL.

FILTERS

TAG

AREA

SERVED

PREFILTER FINAL FILTER REMARKS

QTY.

MERV

RATING

THICKNESS

(IN.)

DIMENSION

(IN.)

QTY.

MERV

RATING

THICKNESS

(IN.)

DIMENSION

(IN.)

F-1 EF1202CD 2 8 2 24X24 2 17 12 24X24 1

NOTES

1. SITE ELVATION = 5,518' ASL

CEILING MOUNTED HEATERS

TAG MANUFACTURER MODEL

AREA

SERVED

FAN HEATING COIL ELECTRICAL SHIPPING

WEIGHT

(LBS.)

REMARKS

CFM

MIN

CFM

ESP

(IN. WC)

TOTAL CAPACITY

(kW)

VOLT/PH FLA

CMH-1 QMARK CDF-547 RESTROOMS 300 0 0.00 3.0 277/1 10.80 125 1,2,3

NOTES:

1. SITE ELEVATION = 5,518' ASL 2. PROVIDE WITH GYP CEILING MOUNTING BRACKETS 3. PROVIDE WITH 'CDFRENW' RECESSED MOUNTING ENCLOSURE

AIR CURTAIN

TAG MANUFACTURER MODEL

AREA

SERVED

MAX

CFM

MAX VELOCITY

ELECTRICAL

dBA

SHIPPING

WEIGHT

(LBS.)

REMARKS

VOLT/PH FLA

AC-180 MARS AIR LPV2 36 1C-180 900 1,800 120/1 2.40 49 32 1

NOTES:

1. SITE ELEVATION = 5,518' ASL

EXHAUST FAN SOUND ATTENUATORS

TAG MANUFACTURER MODEL AREA SERVED CFM VELOCITY (FPM)

DIMENSIONS (IN)

P.D. (IN WG) MATERIAL MEDIA TYPE

DYNAMIC INSERTION LOSS

REMARKS

W H L 63 125 250 500 1000 2000 4000 8000

S-1 VIBRO-ACOUSTICS RNM-XV-FX EF-1201AB 12,700 -1,814 36 28 120 0.32 SS 304 NONE 11 10 8 19 21 25 12 9 1,2,3,4,5

S-2 VIBRO-ACOUSTICS CUSTOM EF-1201CD 700 -1,283 10 ID/30X30 OD 144 0.18 SS 304 NONE 12 25 31 36 15 14 13 13 1,2,3,4,5

S-3 VIBRO-ACOUSTICS CNM-XV-FX EF-2412AB 5,000 -1,894 22 ID/32x32 OD 60 0.18 SS 304 NONE 11 15 33 27 15 12 8 8 1,2,3,4,5

NOTES:

1. CONTRACTOR/SILENCER MANUFACTURER SHALL PROVIDE ACOUSTICAL CALCULATIONS WITH PE STAMP FOR BREAKOUT/DUCT BORNE NOISE TO CERTIFY MAX. 55 DBA IN THE ROOM.

2. CONTRACTOR/SILENCER MANUFACTURER SHALL PROVIDE PRESSURE DROP CALCULATIONS WITH PE STAMP TO CERTIFY THE PRESSURE INCL. SYSTEM EFFECTS, INCLUDING THE NON-IDEAL DUCT ENTRY AND OUTLET CONDITIONS PER PLANS, AS SCHEDULED.

3. FOR NON-BASIS OF DESIGN PRODUCT SUPPLIED, CONTRACTOR IS FINANCIALLY RESPONSIBLE TO ENSURE THE REQUIRED NOISE CONTROL SOLUTION IS DELIEVERED TO ACHIEVE MAX 55 DBA IN ROOM.

4. ALTERNATE MANUFACTURER SHALL PROVIDE SILENCER INTERNAL GEOMETRY FOR ENGINEER'S APPROVAL.

5. SUPPORT ATTENUATOR FROM ROOF MOUNTED DUCT SUPPORTS. DESIGN SUPPORTS TO ACCOUNT FOR INCREASED SIZE OF ATTENATOR BODY AND HAVE SUPPORT STRAPS OVER TOP OF ATTENUATOR.

Project Number:

Drawn By:

Reviewed By:

Approved By:

Issue Date

GENERAL SERVICES ADMINISTRATION

ROCKY MOUNTAIN REGION

MOUNTAIN PLAINS SERVICE CENTER (8PSMP)

P.O. BOX 25546

BUILDING 41

DENVER FEDERAL CENTER

DENVER, CO 80225

303-236-2854

AndersonMasonDale Architects, P.C.

3198 Speer Boulevard

Denver, CO, 80211

Telephone: 303-294-9448

FAX: 303-294-0762

Architect

Iron Horse Architects

475 17th Street, Suite 720

Denver, CO, 80202

Telephone: 720-855-7572

Laboratory Planning

Martin Martin

12499 West Colfax Avenue

Lakewood, CO, 80215

Telephone: 303-431-6100

Structural Engineering

Farnsworth Group

4755 Forge Road, Suite 150

Colorado Springs, CO, 80907

Telephone: 719-590-9194

Mechanical Engineering

MEP Engineering

6402 South Troy Circle, Suite 100

Centennial, CO, 80111-6439

Telephone: 303-936-1633

Electrical Engineering

Jensen Hughes Associates, Inc

520 Courtney Way, Suite A

Lafayette, CO, 80026

Telephone: 303-439-0485

Fire Protection

Advanced Consulting Engineers, Inc

3900 S. Wadsworth Blvd., Suite 595

Lakewood, CO, 80235

Telephone: 720-981-4150

Code Consultant

Parametrix, Inc

7186 South Highland Drive

Salt Lake City, UT, 84121

Telephone: 801-733-5900

Cost Estimator

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice.

Properly destroy or return document when no longer needed.

/1

/2

:0

:0

P M

M-401

MECHANICAL SCHEDULES

2009121.11

KC

TS

TS

EPA BUILDING 25

CO-LOCATION

PROJECT

DENVER FEDERAL CENTER

BUILDING 25, LAKEWOOD, CO

2009121.11

15 APRIL 2016100% Construction Documents

Addendum 01 27 MAY 2016

Addendum 02 05 AUG 2016

Addendum 06 12 OCT 2016

10/12/16

A

A A

I

2928272625

J

K

L

M

(E) SECURITY

1A-080

(E) OFFICE

1A-090

(E) OPEN OFFICE

1A-005

(E) OFFICE

1A-015

(E) OFFICE

1A-025

(E) OFFICE

1A-035

(E) OFFICE

1A-045

(E) OFFICE

1A-055

(E) OFFICE

1A-085

(E) OFFICE

1A-075

(E) OFFICE

1A-110

R8 FIELD PREP

1A-110

ESAT

INSTRUMENTS

1A-235

ESAT

TOXICOLOGY &

GENERAL BIO

1A-245

R8

MACROBIOLOGY

1A-260

SHARED METAL

PREP

1A-265

R8 ORGANIC PREP

1A-270

ESAT ASBESTOS

1A-255A

ESAT ASBESTOS

PLM

1A-255

R8 CLLE

1A-250

MECHANICAL

1B-035

(E) ELEC

1B-025

NEIC FIELD

STORAGE &

STAGING

1A-340

LAB CORRIDOR

C1A5

GAS CLOSET

1A-231

SUPPORT

1A-210

STAIR

ST-02

L A

B C

O R

R

ID

O R

C 1C

"A

W

4"AW

/2 "D

I

AW

/2 "D

I

(E )3

/4 "C

A

(E)4"AW

(E)4"AW

(E )3

/4 "C

A

(E)3/4"CA

(E)1 1/2"DI

(E)1 1/2"DI

(E)1 1/2"DI

1 1

II

JJ

KK

LL

MM

P-201

1 1/2"DI

1 1/2"DI

/4

"V A

C

1"VAC

WCO-1

WCO-1

"A

W

2"AW

(E) NEIC FIELD

SUPPORT

1A-135

(E) NEIC FIELD

SHOP

1A-145

(E) RESTROOM

1A-115

"A

V "A

V

/2 "D

I

(E) TELE ROOM

1B-030

R8 SUPPLIES

1A-220

ACID LIFT

1A-120

SERVICE HALL

C1A3

(E )3

/4 "A

R

(E) OFFICE

1A-095

SERVICE

CORRIDOR

C1A1

CID STAGING AND

STORAGE

1A-345

SERVICE

CORRIDOR

C1A4

GAS CLOSET

1A-254

GAS CLOSET

1A-246

/2 "D

I

2"CA

2" CA FROM AC-3, CONNECT TO PVC

HEADER FOR FISH TANK BUBBLERS,

SEE LAB FURNISHING PLANS

(E)3/4"CA

(E)3/4"CA

(E )3

/4 "C

A (E

)3 /4

"C A

(E)3/4"CA

(E)1 1/2"DI

2"AW(E)4"AW

7 7

WCO-1

1/2"CA

N

HE

N2

CA

CA

HE

N

/2 "A

V

AV

AW

"A

W

4"AW 4"AW

4"AW

"A

V

"A

W

2"AV

2"AV

2"AW

AW PIPING

ABOVE GRADE

AW PIPING

BELOW GRADE

1 1/2"N2

1 1/2"N2

1 1/2"N2

GENERAL NOTES

Project Number:

Drawn By:

Reviewed By:

Approved By:

Issue Date

GENERAL SERVICES ADMINISTRATION

ROCKY MOUNTAIN REGION

MOUNTAIN PLAINS SERVICE CENTER (8PSMP)

P.O. BOX 25546

BUILDING 41

DENVER FEDERAL CENTER

DENVER, CO 80225

303-236-2854

AndersonMasonDale Architects, P.C.

3198 Speer Boulevard

Denver, CO, 80211

Telephone: 303-294-9448

FAX: 303-294-0762

Architect

Iron Horse Architects

475 17th Street, Suite 720

Denver, CO, 80202

Telephone: 720-855-7572

Laboratory Planning

Martin Martin

12499 West Colfax Avenue

Lakewood, CO, 80215

Telephone: 303-431-6100

Structural Engineering

Farnsworth Group

4755 Forge Road, Suite 150

Colorado Springs, CO, 80907

Telephone: 719-590-9194

Mechanical Engineering

MEP Engineering

6402 South Troy Circle, Suite 100

Centennial, CO, 80111-6439

Telephone: 303-936-1633

Electrical Engineering

Jensen Hughes Associates, Inc

520 Courtney Way, Suite A

Lafayette, CO, 80026

Telephone: 303-439-0485

Fire Protection

Advanced Consulting Engineers, Inc

3900 S. Wadsworth Blvd., Suite 595

Lakewood, CO, 80235

Telephone: 720-981-4150

Code Consultant

1A

1B

1C

1D

PLAN KEYPLAN KEY

Parametrix, Inc

7186 South Highland Drive

Salt Lake City, UT, 84121

Telephone: 801-733-5900

Cost Estimator

SENSITIVE BUT UNCLASSIFIED (SBU)

PROPERTY OF THE UNITED STATES GOVERNMENT

FOR OFFICIAL USE ONLY

Do not remove this notice.

Properly destroy or return document when no longer needed.

/1

/2

:0

:0

P M

P-111A

FIRST LEVEL LAB PLUMBING PLAN -

AREA A

2009121.11

JB

RF

TS

EPA BUILDING 25

CO-LOCATION

PROJECT

DENVER FEDERAL CENTER

BUILDING 25, LAKEWOOD, CO

2009121.11

15 APRIL 2016100% Construction Documents

1/8" = 1'-0"1

FIRST LEVEL LAB PLUMBING PLAN -

AREA A

1. PROVIDE 1/2" DEIONIZED WATER TO OUTLETS. PROVIDE 1-1/2" ACID VENT, CONNECT TO EXISTING PIPE ABOVE CEILING.

2. ALL SPECIALTY GAS CYLINDERS AND DEWARS PROVIDED AND INSTALLED BY OWNER'S GAS VENDOR. COORDINATE WITH VENDOR FOR INSTALLATION REQUIREMENTS AND DELIVERY. FROM CYLINDER OR DEWAR IN GAS CLOSET, TUBING IS ROUTED ABOVE CEILING, DOWN TO OVERHEAD CARIER (WITH ESCHUTECHEON PLATE AT CEILING PENETRATION) AND ROUTED ALONG OVERHEAD CARRIER , WHERE PRESENT. REFER TO LAB PLAN DRAWINGS FOR LOCATIONS OF OUTLETS AND PROVIDE AND INSTALL VALVED SPIGOT FOR LOCAL ISOLATION AND PRESSURE REDUCING VALVE AT EACH TAP SHOWN ON LAB PLANS. FINAL TUBING CONNECTION FROM ISOLATION AND PRESSURE REDUCING VALVES TO LAB

EQUIPMENT BY LAB EQUIPMENT INSTALLER. SEE DETAIL 5/P-604.

3. INSTALL DUPLEX PUMP ACID WASTE LIFT STATION. CONNECT PUMPED ACID WASTE LINE TO EXISTING GRAVITY DRAIN ACID

WASTE SYSTEM. PLACE ON EMERGENCY POWER.

4. PROPOSED NEW TO EXISTING ACID WASTE POINT OF CONNECTION. ELEVATION AT POINT OF CONNECTION TO BE

DETERMINED.

5. PROVIDE HIGH VOLUME DI TAP [1-1/2"] WITH THREADED END FOR HOSE CONNECTION. PROVIDE WITH LOCKABLE - BALANCE

VALVE TO RESTRICT FLOW WITHIN MAKE-UP LIMIT OF DI SYSTEM.

6. OVERHEAD SERVICE CARRIER. REFER TO ENLARGED LAB PLANS FOR QUANTITY AND TYPE OF CONNECTIONS. TYPICAL ALL.

# KEY NOTES

RE: 1/P-111B

R E

/P

-1

B

R E

/P

-1

D

RE: 1/P-111D

7. ADD STUB OUT WITH DIAPHRAGM VALVE FOR FUTURE POLISHER CONNECTION, WHERE THERE IS NO EXISTING STUB. SEE DETAIL 3/P-604

FOR PIPING, REFER TO LF SHEETS FOR POLISHER INFO.

8. GAS CLOSET FOR ESAT INSTRUMENTS LAB. PROVIDE (3) 1/4" SS TUBES FROM 4'-0" AFF IN GAS CLOSET TO OUTLETS. SEE DETAIL 5/P-604.

9. GAS CLOSET FOR R8 CLLE LAB.

10. CONNECT 3/4" CD FROM HUB DRAIN TO WASTE PIPING, SEE HUB DRAIN DIAGRAM 1/P-604. SEE P-101A FOR HUB DRAIN LOCATION.

11. (NOT USED)

12. EXTEND VACUUM SERVICE PIPE TO ABOVE-COUNTER SPIGOT ON BOTH SIDES OF WALL, SEE LAB FURNISHING PLAN FOR EXACT LOCATION.

13. ROUTE N2 PIPING MAIN DOWN IN ARCHITECTURAL COLUMN TO COUNTER HEIGHT AND EXTEND TO OUTLETS. SEE LAB FURNISHING PLAN FOR

EXACT LOCATION. COORDINATE ROUTING WITH EXHAUST DUCTING.

14. ROUTE AIR MAIN THROUGH CEILING AND CONNECT TO DISTRIBUTION PIPING. SEE LAB FURNISHING PLANS FOR DISTRIBUTION PIPING.

15. GAS VENDOR SHALL PROVIDE AND INSTALL MANIFOLD ON WALL ABOVE CYLINDERS FOR CONNECTION OF GAS CYLINDERS. ROUTE PIPING FROM MANIFOLD INTO THE WALL AND UP TO ABOVE CEILING. ROUTE TO DROPS AS SHOWN ON PLANS. DROPS SHALL BE WITHIN WALLS AND LAB CASEWORK AND EXTEND OUT OF WALL TO PRESSURE REDUCING VALVE AND ISOLATION VALVE. PIPING SHALL BE SIMILAR TO 5/P-604 FOR GAS

PIPING FROM GAS CLOSET.

1. ALL RENOVATION WORK IS PHASED. WORK AREA SHALL BE GROUPED AS REQUIRED BY OWNER. REFER TO ARCHITECTURAL PHASING PACKAGE TO BE ISSUED BY ADDENDUM. ALL SERVICES SHALL BE MAINTAINED TO AREAS NOT WITHIN THE RENOVATION AREA OF EACH PHASE. COORDINATE SYSTEM OUTAGES OF COMPRESSED AIR, DEIONIZED WATER AND ACID WASTE WITH OWNER, MINIMUM 3 WEEKS IN ADVANCE. OUTAGES ARE SCHEDULED AS BEST ACCOMMODATES OWNER SCHEDULE. PROVIDE TEMPORARY SERVICES FOR OUTAGES LASTING LONGER THAN SCHEDULED – SUBMIT PLAN FOR TEMPORARY SERVICES. PROVIDE PIPING CONNECTIONS FOR TEMPORARY SERVICES TO ALLOW FOR FULL USE OF BUILDING AREAS NOT PART OF CURRENT

RENOVATION PHASE.

2. DO NOT USE PIPE DOPE ON THREADED PIPING CONNECTIONS FOR LAB GAS PIPING SYSTEMS.

3. GAS TUBING TO LAB EQUIPMENT FROM CYLINDERS IN LABS (CYLINDERS NOT IN GAS CLOSETS) IS PROVIDED BY

LAB EQUIPMENT INSTALLER, UNLESS OTHERWISE NOTED.

1 1

Addendum 01 27 MAY 2016

Addendum 02 05 AUG 2016

Addendum 06 12 OCT 2016

A A

A A A

3332313029282726

L

M

N

O

P

Q

NEIC FIELD

STORAGE &

STAGING

1A-340

(E) SAF

COMMUNICATION

ROOM

1A-370

SAF HALL

1A-360

SHARED

HAZARDOUS

SAMPLES

RECEIPT &

STORAGE

1C-225A

R8 SAMPLE

RECEIVING &

STORAGE

1C-225B

(E )3

/4 "C

A

(E)AW

(E )4

"A W

(E )A

W

(E)AW

(E)3/4"CA

(E)1/2"CA

(E)1/2"CA

(E )1

/2 "C

A

(E)1 1/2"DI

(E)1 1/2"DI

(E)AR

(E)1 1/2"DI

(E)AR

LL

MM

NN

OO

PP

QQ

3/4"CA

DI

(E) NEIC FIELD

SHOP

1A-145

(E) NEIC FIELD

CALIBRATION

1A-355

UP TO 3" AVTR

SERVICE HALL

C1A3

CID STAGING AND

STORAGE

1A-345

(E) ELEC

1A-350

(STAIR

ST-01

(E) SHIPPING /

RECEIVING

VESTIBULE

1A-475

SERVICE

CORRIDOR

C1A4

(E) CONFERENCE

1A-465(E) VESTIBULE /

AUTOCLAVE

1A-455

(E) SCREENING

LAB

1A-460

(E) SHOWER

1A-461

(E) LOCKER

1A-462

(E) RESTROOM

1A-463

(E) GAS CLOSET

1C-464

(E) SHIPPING /

RECEIVING

1A-505

(E) VESTIBULE

1A-466

(E) RECEIVING

AND MAIL

1C-516

(E) MAIL ROOM

OFFICE

1C-517

(E) SHARED

GRINDING LAB

1C-245

SHARED GARAGE

BAY

1A-375

3"AV1/2"CA

UP TO 3" AVTR

(E)3/4"CA

(E)1 1/2"DI

(E)3/4"CA

(E)3/4"CA

(E)3/4"CA

(E)3/4"CA

(E )3

/4 "C

A

(E)3/4"CA

(E )3

/4 "C

A

(E )A

W

(E )1

"C A

(E )4

"A W

(E )D

I (E

)1 "C

A (E

)D I

1/2"DI

(E)AW, BELOW SLAB

PIPING ABOVE

CEILING.

PIPING ABOVE

CEILING.

ROUTE IN

CARRIER.

1 1/2"AV

1 1/2"AW

1 1/2"AV

1 1/2"AW

2"AW

GENERAL NOTES

Project Number:

Drawn By:

Reviewed By:

Approved By:

Issue Date

GENERAL…