FSV6-631-01_REV(B) Paint Schedule.pdf
PDF 637 KB Posted
- Attached to
- NOAA Ship REUBEN LASKER Unscheduled Dry Docking
- Solicitation number
- 1305M223QNMAN0180
About this file
This document provides a paint schedule for a NOAA Fisheries Survey Vessel. It specifies 36 different paint systems to be applied to various parts of the vessel, both above and below the waterline. Paint types include epoxy, alkyd, and ablative antifouling coatings. Surface preparation methods and specifications are provided for each area. The schedule also includes a list of materials with part numbers, quantities estimated, and manufacturers. General notes cover topics like required surface preparation, environmental conditions for application, color coding of systems, and hull markings.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET
1A 1B 1C
3 GENERAL NOTES
3A GENERAL NOTES (Continued)
4 LIST OF MATERIALS
5 LIST OF COMPARTMENTS (Modules 101. 102. 103, 201) 5A LIST OF COMPARTMENTS (Modules 201, 202) 5B LIST OF COMPARTMENTS (Modules 202, 301, 302, 303, 401, 402, 403) 5C LIST OF COMPARTMENTS (Modules 403, 501, 502) 4 FSV6-635-01 5D LIST OF COMPARTMENTS (Modules 502, 503, 505, 507) 3 FSV6-602-01
6 PAINT SYSTEM "D-1" 2 FSV6-634-01
7 PAINT SYSTEM "D-2" 1 FSV6-601-01
8 PAINT SYSTEM "D-3" NO. MMC DRAWING NO.
9 PAINT SYSTEM "D-4"
10 PAINT SYSTEM "D-5"
11 PAINT SYSTEM "D-6"
12 PAINT SYSTEM "D-7"
12A PAINT SYSTEM "D-77A"
13 PAINT SYSTEM "D-8"
14 PAINT SYSTEM "E-1"
15 PAINT SYSTEM "E-2"
16 PAINT SYSTEM "E-3"
17 PAINT SYSTEM "E-4"
18 PAINT SYSTEM "I-1"
18A PAINT SYSTEM "I-1A"
19 PAINT SYSTEM "I-2"
20 PAINT SYSTEM "I-3"
20A PAINT SYSTEM "I-3A"
21 PAINT SYSTEM "I-4"
21A PAINT SYSTEM "I-4A"
22 PAINT SYSTEM "I-5"
23 PAINT SYSTEM "I-6" DATE:
24 PAINT SYSTEM "M-1"
25 PAINT SYSTEM "M-2" DATE:
26 PAINT SYSTEM "M-3" SH 1 OF 51
SHEET 1
APRV: C. JACKSON
Visual Identification & Draft Marks Insulation & Damping Tile A&D
PE STAMP:
DATE:
CONTRACT NO: AB133M10CN0091
FISHERIES SURVEY VESSEL 6
(FSV 6)
Deck Covering Schedule
REV
B
MARINETTE MARINE CORPORATION
MARINETTE WISCONSIN 54143
SCALE: NONE
PAINT SCHEDULE
FSCM CAGE NO
98042
INDEX
DESCRIPTION
TITLE, INDEX
PAINT SYSTEM LEGEND
PAINT SYSTEM LEGEND (Continued)
INDEX CONTINUDED
REVISIONS
General Arrangement, Inboard & Outboard Profiles
DRAWING NO.
FSV6-631-01
SIZE
A
NATIONAL OCEANIC &
ATMOSPHERIC ADMINISTRATION
(NOAA)
ABS APRV:
APRV: J. BRISKY
CHKD: T. ZMYSLO
DWN: J. K. EASTRIDGE
USCG APRV:
TITLE
REFERENCES
SHEET
27 PAINT SYSTEM "M-4"
28 PAINT SYSTEM "M-5"
28A PAINT SYSTEM "M-5A"
29 PAINT SYSTEM "M-6"
30 PAINT SYSTEM "M-7"
30A PAINT SYSTEM "M-7A"
31 PAINT SYSTEM "T-1"
32 PAINT SYSTEM "T-2"
33 PAINT SYSTEM "T-3"
34 PAINT SYSTEM "T-4"
35 PAINT SYSTEM "U-1"
36 PAINT SYSTEM "U-2"
DATE:
DATE:
SHEET 1A
INDEX
DESCRIPTION
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
0120-631-01
Decks
D-1 D-2 D-3 D-4 D-5 D-6 D-7 D-7A D-8
Exterior E-1
E-2 E-3
E-4
Interior I-1
I-1A
I-2 I-3 I-3A I-4 I-4A I-5 I-6
Misc.
M-1 M-2 M-3 M-4 M-5 M-5A M-6
M-7 Uninsulated areas that are in way of weather boundries. - ALKYD PRIMER
M-7A Uninsulated areas that are in way of weather boundries. - EPOXY PRIMER DATE:
DATE:
SHEET 1B
Machinery & foundations in machinery spaces above floor plates where temperature is less than 93 deg C. - EPOXY PRIMER
Aluminum deck surfaces requiring only primer in preparation for deck covering. - EPOXY PRIMER
Shell exterior (steel) from waterline up, including outboard side of bulwarks, exterior steel deckhouses, vents, overflows, overhead surfaces, deck gear lockers, doors, stanchions, vertical & inclined ladders, handrails, ventilators, bulwark-mounted chocks, davits, steel monorails
Exposed interior steel bulkheads & overheads in machinery spaces, service spaces, workshops, storerooms, deck lockers, interior railings, stanchions & associated fittings - EPOXY PRIMER
Interior steel ladders (excluding ladders in tanks) - EPOXY PRIMER
Unexposed steel structure behind insulation and/or joiner panels - EPOXY PRIMER
Machinery & foundations in machinery spaces above floor plates where temperature is less than 93 deg C. - ALYKD PRIMER
Bilges
Unexposed steel structure behind insulation and/or joiner panels - ALKYD PRIMER
Exterior exposed vertical aluminum surfaces including vents, overflows, deck gear lockers, doors, stanchions, vertical and inclined ladders, handrails, ventilators, stack (excluding special markings) & underside of exposed aluminum deckheads.
Steel masts, booms, gantries, A-frames and similar fittings and equipment
Interior steel ladders (excluding ladders in tanks) - ALKYD PRIMER Exposed interior aluminum bulkheads & overheads
Exposed interior steel bulkheads & overheads in machinery spaces, service spaces, workshops, storerooms, deck lockers, interior railings, stanchions & associated fittings - ALKYD PRIMER
Aluminum masts, booms, trusses and similar fittings & equipment
Exposed insulation IWO aluminum structure, but not type II acoustic insulation.
PAINT SYSTEM LEGEND
Steel deck surfaces requiring only primer in preparation for deck covering. - EPOXY PRIMER Steel deck surfaces requiring only primer in preparation for deck covering. - ALKYD PRIMER
SCALE: NONE
Exterior Steel decks, house tops, hatch covers & coamings, inboard side of bulwark.
Interior steel decks in AMR & service spaces, workshops, storerooms, deck lockers and similar spaces.
Exterior Aluminum decks, house tops, hatch covers & coamings, foundations & deck fittings.
Exposed interior Aluminum decks.
Misc. exterior steel deck fittings, deck-mounted machinery, chocks, cleats, bitts.
Walking surfaces of steel floor plates, grating, decks & platforms in main machinery spaces.
Anchor Anchor Chain Chain locker & sump Engine exhaust and other surfaces above 93 deg. C. (excluding lagged exhaust piping)
Inaccessible voids
Continued on Sheet 1C
REV
BABS APRV:
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
FSV6-631-01
Tanks T-1 T-2 T-3 T-4
Under Water U-1 U-2
DATE:
DATE:
SHEET 1C
REV
BABS APRV:
PAINT SYSTEM LEGEND (Continued)
Fuel oil, Lube oil, & dirty oil tanks (steel) Steel ballast tanks, sewage and gray water tanks, misc. tanks & voids, steel portion of the centerboard trunk, transducer tube Fresh & potable water tanks (steel) Aluminum tank and trunk interiors
SCALE: NONE
Note: Ladders inside tanks to receive same coating as tank interior)
Exterior underwater body including trunks and appendages, but excluding seachests Seachests
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
0120-631-01
SHT REV DATE APPROVED
ALL - 9/27/2010 T. ZMYSLO
5/16/2013 RRZ
7/23/2013 PWH
DATE:
DATE:
SHEET 2
5,5B,33
1,1A,1B,1C 3A,5,5B,5C
3A,8,9
5A
DRAWING REVISION B ISSUED "AS-BUILT"
1. REVISED FWD BHD OF COMPT NO. 3-29-1 FROM I-1 TO M-7 ANTISWEAT
TREATMENT.
2. REVISED 6.2 M TO 6.25 M.
ITEM 1 TO SUIT ECN 631-01-010.
ITEM 2 TO SUIT GOVT. RESPONSE dtd 7/12/13
B5
14,35
DESCRIPTION
INTIAL ISSUE
SCALE: NONE
REVISIONS
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
INCORPORATED ECN 001.
INCORPORATED ECN 002.
INCORPORATED ECN 003 - ADD SHEET 36.
ECN 004 - Supercede with ECN 005 - NO CHANGE.
INCORPORATED ECN 005 - ADD SHTS 12A,18A,20A,21A,28A,30A & ADDED GEN. NOTE
#16.
INCORPORATED ECN 006 - ADD GEN. NOTE #15.
ECN 007 - NOTED SIM. TO ECN 006 - NO CHANGE.
INCORPORATED ECN 008
INCORPORATED ECN 009
GOVERNMENT RESPONSE(s) DATED 6-4-12 & 11-10-12 Update to Suit ECN 003 comment add Bow Thruster Tunnel Text to Area box.
A
DATE:
DATE:
SHEET 3
Continued on sheet 3A
GENERAL NOTES
1. Surfaces of fuel oil, lube oil, and dirty oil tanks are to be run through the wheelabrator for removal of mill scale, and are to be left uncoated.
All preconstruction primer shall be removed prior to fueling.
2. All paints and coatings shall be mixed and applied in accordance with standard painting procedures and manufacturers recommendations.
The coating manufacturer’s instructions for acceptable ambient and metal surface temperature, relative humidity, and dew point, surface cleanliness, surface profile, dry film thickness, and drying/cure/recoat times shall be followed.
3. IF required, equipment with factory installed coating systems shall be touched up with matching paint.
4. Do not paint door hardware, cathodic protection anodes, bond straps, heat exchanger surfaces, gasket seats, lubricating fittings, nameplates, labels & signs, threads and working surfaces, rubber & other elastomers, discharge nozzles, decorative & finished parts of furniture, furnishings & equipment, isolation mounts, type II acoustic treatment, and below waterline temperature sensors and acoustic transducers. Surfaces of unexposed aluminum structure behind insulation and/or joiner panels do not require coating. Perforated sheathing shall not be sprayed after installation.
5. Surface to be painted must be at least 5 degrees F above dew point to prevent condensation.
6. Anchor Chain Markings:
The anchor chains shall be painted and marked to identify the length of chain paid out as follows:
a. One link on each side of the 15 fathom detachable link shall be painted white, Part Number N3.
b. Two links on each side of the 30 fathom detachable link shall be painted white, Part Number N3.
c. Three links on each side of the 45 fathom detachable link shall be painted white, Part Number N3.
Marking shall continue in this fashion to the bitter end of the chain.
Detachable links shall be painted as follows:
a. 15 fathom detachable link, red, Part Number N6.
b. 30 fathom detachable link, white, part Number N3.
c. 45 fathom detachable link, blue, Part Number N7.
d. 60 fathom detachable link, red, Part Number N6.
Subsequent detachable links shall be painted in colors that continue this color sequence.
7. Hull markings shall be located IAW Ref 3 and painted (DFT 4 mil) with the following:
Hull Mark Part Number Draft Marks (Calculative & appendage) N3 OR N5 Thruster Marks N5 Ship's Name N5 NOAA Symbol N7 OR N9
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
8. Where referred to this note from the list of compartments, paint system I-4 and I-6 shall be used in way of exposed structure and insulation.
9. Where referred to this note from the list of compartments, paint system I-4 shall be used in way of exposed structure.
10. Engine exhaust and other surfaces above 93 degrees C, unlagged shall use Paint System "M4".
11. Foundations above floor plates in machinery spaces shall use Paint System "M5".
12. Uninsulated area's which are weather boubdries shall use Paint System "M-7".
13. Valve hand wheels, operating levers and root valves away from guageboards located in the interior of the ship shall be color coded for training, troubleshooting, quick identification, proper operation of particular systems and critical control or casualty control process.
Fresh Water Machinery Cooling Dark Blue COOLING FW Fresh Water Potable Light Blue POTABLE WTR Seawater Green SW Uncontaminated Seawater Green Stripped UNCSW Fire Systems and Mains Red FIREMAIN Diesel Fuel Brown DIESEL Lubricating Oil Yellow LO Hyraulic Systems Orange HYDRAULIC Ship Service Air Black SS AIR Starting & Control Air White S/C AIR Sewage Brown/Yellow SEWAGE Vacuum Yellow/Red VAC Chilled Water Green/Blue CHILLED Diver's Air Black/White DIVERS AIR
14. All resident US Navy and Trelleborg/Metalastick type shock mounts within structural machinery mounts shall be coated with Spraylat SC-1071T Strippable Coating prior to any other painting within he immediate area. Particular attention shall be paid to mounts for large machinery.
15. All aluminum exterior decks and 150mm up adjacent verticle surfaces, house tops, exterior hatch covers, foundations, deck fittings and inboard side bulwalks shall be sweep blasted SSPC-SP-7 prior to application of specified coatings.
16. Interior steel surfaces that are to receive systems D-7, I-1, I-2, I-3, I-4, M-5 and M-7 were primed with N22 Amercoat 385 in compartments located in Modules 101, 103, 201, 202, 301, 302 and 401. D-7A, I-1A, I-4A, M-5A and M-7A were primed were primed with N14 Amercoat 385 in compartments located in modules 102, 303, 402, 403, 501, 502, 505, and 506. DATE:
DATE:
SHEET 3A
REV
BABS APRV:
SCALE: NONE
GENERAL NOTES (Continued)
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
System Color Abbreviation
PART
NO.
UNIT OF
MEAS
Qty
(EST)
COLOR
N1 Gallon 98 Terracotta N2 Gallon 98 Black N3 Gallon 109 White N4 N5 Gallon 23 Black N6 Gallon 3 Red N7 Gallon 5 Dark Blue N8 Gallon 16 Buff N9 Gallon 2 Light Blue N10 Gallon 13 White N11 Gallon 7 Haze Gray N12 Gallon 13 Buff N13 Gallon 80 Green N14 Gallon 636 Terracotta N15 Gallon 108 Black N16 Gallon 60 Off White N17 Gallon 217 Dark Gray N18 Gallon 11 Terracotta N19 Gallon 11 Black N20 Gallon 4 Aluminum N21 Gallon 5 Black N22 Gallon 190 Terracotta N23 Gallon 385 NQA933 Gray
N24 Gallon 55 N/A
N25 Gallon 384 White N26 Gallon 9 Gray N27 Gallon 122 White N28 Gallon 61 Haze Grey N29 Gallon 122 Buff N30 Gallon 10 White N31 N32 Gallon 55 N33
DATE:
DATE:
SHEET 4SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
LIST OF MATERIALS
Ablative antifouling Ameron ABC #4 Epoxy, acrylic, gloss Ameron Amercoat 229C
DESCRITON
TYPE/CLASS/GRADE
MFG. PRODUCT
NAME/NUMBER
Ablative antifouling Ameron ABC #4
REMARKS
Epoxy, acrylic, gloss Ameron Amercoat 229T Epoxy, acrylic, gloss Ameron Amercoat 229T
NOT USED
Epoxy, acrylic, gloss Ameron Amercoat 229T
Epoxy, high solids Ameron Amerlock 2 Epoxy, high solids Ameron Amerlock 2
Epoxy, acrylic, gloss Ameron Amercoat 229T Epoxy, acrylic, gloss Ameron Amercoat 229T
Epoxy, multipurpose Ameron Amercoat 385 Epoxy, multipurpose Ameron Amercoat 385
Epoxy, high solids Ameron Amerlock 2 Primer, reinforced inorganic zinc Ameron Dimetcote 302H
Epoxy, high solids, glass flake Ameron Amerlock 400GFK Epoxy, high solids, glass flake Ameron Amerlock 400GFK
Glassflake Glassflake
Epoxy, multipurpose Ameron Amercoat 385 Epoxy, multipurpose Ameron Amercoat 385
Primer, Alkyd Ameron Amercoat 5105 Pre-construction Primer International Interplate 937
High temperature silicone coating Ameron Amercoat 878 Top Coat, alkyd, gloss Ameron Amercoat 5450
Top Coat, alkyd, gloss Ameron Amercoat 5450 Epoxy, Universal, Semigloss Ameron Amercoat 240
FLO-COAT MIL-C-16173
Eureka Chemical Company
Fluid Film A Top Coat, alkyd, gloss Ameron Amercoat 5450
Fill & drain inaccessible voids
Epoxy, Universal, Semigloss Ameron Amercoat 240 Temp-Coat, Antisweat Treatment Temp-Coat 101
Epoxy, Universal, Semigloss Ameron Amercoat 240
Holding Primer Picklex 20 Inhibitor Test Equipment Elcometer
NO.
UNIT OF
MEAS
Qty
(EST)
COLOR
N34 Gallon 270 White N35 Gallon 68 Oxide Red N36 Gallon Buff N37 Gallon 5 Red N38 Gallon 5 Brown N39 Gallon 5 Yellow N40 Gallon 5 Orange N41 Gallon 5 Black N42 Gallon 5 Blue N43 Gallon 5 Dark Blue N44 Gallon 5 Light Blue N45 Gallon 5 Green N46 Gallon 1 Silver N47 Gallon 50 N48 Gallon 50
DATE:
DATE:
SHEET 4ASCALE: NONE
Mid Graphite Gray
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
Nonskid Aggregate Amercoat 888 Aluminum Oxide Epoxy Multi-Purpose Amercoat AT 385-257
Topcoat, Alkyd Gloss Amercoat 5450 Brite Zinc Brite zinc Gallon Can Touch Up Galvanizing
Topcoat, Alkyd Gloss Amercoat 5450 Topcoat, Alkyd Gloss Amercoat 5450
Topcoat, Alkyd Gloss Amercoat 5450 Topcoat, Alkyd Gloss Amercoat 5450
Topcoat, Alkyd Gloss Amercoat 5450 Topcoat, Alkyd Gloss Amercoat 5450
Topcoat, Alkyd Gloss Amercoat 5450
Potable Water Tank Lining Amercoat 133 Epoxy Multi-Purpose Primer Sigmacover 435US
LIST OF MATERIALS
DESCRITON
TYPE/CLASS/GRADE
MFG. PRODUCT
NAME/NUMBER
REMARKS
Potable Water Tank Lining Amercoat 133
Topcoat, Alkyd Gloss Amercoat 5450
DECK OVHD FWD AFT PORT STBD
101 4-1-0 T-2 T-2 T-2 T-2 T-2 T-2 101 4-7-1 - - - - - - 101 4-7-2 - - - - - - 102 1-4-0 D-2 I-4A I-4A I-1A I-4A I-4A 102 1-7-0 - I-4A I-4A I-4A I-4A N/A 102 2-5-0 D-7A M-3 M-3 M-3 M-3 M-3 102 2-7-0 D-2 I-1A I-4A I-1A I-4A I-1A 102 4-1-0 T-2 T-2 T-2 T-2 T-2 T-2 102 1-7-1 D-7A I-4A I-4A I-1A I-1A I-1A 102 1-16-1 D-2 I-4A I-1A I-1A I-1A I-4A 102 2-7-1 D-2 I-1A I-4A I-1A I-1A I-4A 102 2-11-1 D-7A I-1A I-1A I-1A I-1A I-4A 102 1-11-2 D-7A I-4A I-4A I-4A I-4A I-4A 102 2-16-2 D-7A I-1A I-1A I-1A I-4A I-1A 102 1-7-3 D-2 I-4A I-4A I-1A I-1A I-4A 103 3-13-0 D-2 I-4 I-4 I-4 I-4 I-4 103 4-13-0 U-2 U-2 U-2 U-2 U-2 U-2 103 4-19-0 T-2 T-2 T-2 T-2 T-2 T-2 103 4-23-0 D-2 I-1 I-1 I-1 I-1 I-1 103 3-19-1 T-3 T-3 T-3 T-3 T-3 T-3 103 4-13-1 T-2 T-2 T-2 T-2 T-2 T-2 103 4-19-1 - - - - - - 103 3-19-2 T-3 T-3 T-3 T-3 T-3 T-3 103 4-13-2 T-2 T-2 T-2 T-2 T-2 T-2 103 4-19-2 - - - - - - 201 3-29-0 D-2 I-4 I-4 I-4 I-4 I-4 201 3-29-1 D-2 I-4 M-7 I-1 I-1 I-4 201 3-31-0 D-2 I-1 I-1 I-1 I-1 I-1 201 3-32-1 D-2 I-4 I-1 I-1 I-1 I-4 201 4-29-0 - - - - - ` 201 4-29-1 T-2 T-2 T-2 T-2 T-2 T-2 201 4-29-2 T-2 T-2 T-2 T-2 T-2 T-2 201 3-39-0 D-2 I-1 I-1 I-1 I-1 I-1 201 3-39-1 - - - - - - 201 3-39-2 - - - - - -
DATE:
DATE:
SHEET 5
REV
BABS APRV:
Scientific Stores
LIST OF COMPARTMENTS (BY MODULE)
SURFACE SYSTEMMODULE COMPT # DESIGNATION
Forepeak Ballast DT #1FS Fuel Oil DT #1FP Fuel Oil Scientific Stores
Freeze Room Chain Locker
REMARKS
See General Note 1
DT #1AP Ballast DT#2P Fuel Oil
Fresh Water Tank DT #1AS Ballast DT#2S Fuel Oil
Fresh Water Tank
Access Dry Stores
Bow Thruster Mchry Room Bow Thruster Seachest
Permanent Ballast Transducer Room
Chill Room
See General Note 1
DT #3P Ballast Auxiliary Machinery Room
Fuel Oil Day Tank Fuel Oil Day Tank
Domestic Equipment Room
Access
DB #3C FUEL OIL
DT #3S Ballast
Locked Stores
General Stores
EM Bhd=I-1 Forepeak Ballast Stores Loading
Fan Room Steward Stores
Laundry
See General Note 1
See General Note 1
See General Note 1
Antisweat Required @ FWD bulkhead
See General Note 1 See General Note 1
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
201 3-47-0 D-2 I-1 I-4 I-4 I-4 I-4 201 3-47-01 - - - - - - 201 4-34-0 T-2 T-2 T-2 T-2 T-2 T-2 201 4-39-0 T-2 T-2 T-2 T-2 T-2 T-2 201 4-39-01 - - - - - - 201 4-39-1 - - - - - - 201 4-39-2 - - - - - - 201 4-47-1 - - - - - - 201 4-47-2 T-2 T-2 T-2 T-2 T-2 T-2 202 1-19-0 D-7 I-4 I-4 I-4 I-4 I-4 202 2-19-0 D-2 I-1 I-4 I-4 I-4 I-4 202 2-29-0 D-2 I-1 I-4 I-1 I-4 I-4 202 3-31-0 D-2 I-1 I-1 I-1 I-1 I-1 202 1-19-1 D-7 I-4 I-4 I-4 I-4 I-4 202 1-31-1 D-7 I-4 I-4 I-4 I-4 I-4 202 2-19-1 D-7 I-4 I-4 I-4 I-4 I-4 202 2-19-2 D-2 I-1 I-4 - - I-1 202 2-19-4 D-7 I-1 I-4 I-4 I-4 - 202 2-19-6 D-2 I-1 I-4 I-4 I-4 - 202 1-33-1 D-2 I-4 - I-1 I-1 - 202 1-36-0 D-7 I-1 I-1 I-1 I-1 I-1 202 1-38-2 D-7 I-4 I-4 I-4 I-4 I-4 202 1-40-1 D-2 I-4 I-4 I-4 I-4 I-4 202 1-43-2 D-7 I-1 I-1 I-4 I-1 I-4 202 2-29-1 D-7 I-4 I-4 - - I-4 202 2-29-2 D-7 I-4 I-4 - I-4 - 202 2-34-1 D-7 I-4 - I-4 I-1 I-4 202 2-34-2 D-7 I-4 - I-4 I-4 I-4 202 2-39-0 D-7 I-1 I-4 I-1 I-4 I-4 202 2-39-1 D-2 I-4 I-4 - I-4 - 202 2-39-3 D-7 I-4 I-4 - - I-4 202 2-39-2 D-7 I-4 I-4 - I-4 - 202 2-44-1 D-7 I-4 - I-4 I-4 I-4
DATE:
DATE:
SHEET 5A
LIST OF COMPARTMENTS (BY MODULE)
MODULE COMPT # DESIGNATION SURFACE SYSTEM REMARKS
Access Lube Oil Tank See General Note 1
Waste Water Tank Centerboard Trunk
DB #4C Fuel Oil See General Note 1 DB #4S Fuel Oil See General Note 1 DB #4P Fuel Oil See General Note 1 Waste Oil Tank See General Note 1
Oily Water Waste Tank Mess Room IMU Room
Passage Access
Galley / Scullery Dry Lab
Stateroom (2) CG Locker
Exercise Room Access
Scientific Equipment Room Passage
Acoustic / Computer Lab Hydrographic Lab
Toilet Stateroom (2) Stateroom (2) Stateroom (2) Stateroom (2)
Passage Linen Locker
Stateroom (2) Stateroom (2) Stateroom (2)
USCG APRV:
REV
BABS APRV:
SCALE: NONE
SIZE
A
FSCM CAGE NO
98042
202 2-44-2 D-7 I-4 - I-4 I-4 I-4 202 4-39-0 - - T-2 T-2 T-2 T-2
301 3-68-0 D-2 I-4 I-1 I-1 I-4 I-4
301 3-69-2 D-2 I-1 I-1 I-1 I-1 I-1 301 4-49-0 D-6 I-4 I-4 I-4 I-4 I-4 301 5-49-0 - - - - - - 301 4-61-1 U-2 U-2 U-2 U-2 U-2 U-2 301 4-61-2 U-2 U-2 U-2 U-2 U-2 U-2
301 4-49-1 VOID T-2 T-2 T-2 T-2 T-2 T-2
302 2-63-0 D-7 I-4 I-4 I-4 I-4 I-4 303 1-36-0 D-7A I-1A I-1A I-1A I-1A I-1A 303 1-47-0 D-7A I-4A I-4A I-4A I-4A I-4A 303 1-51-2 D-2 I-1A I-4A I-4A I-4A I-4A 303 1-56-2 D-7A I-1A I-1A I-1A I-1A I-1A 303 1-58-1 D-7A I-4A I-4A I-4A I-4A I-4A 303 1-58-2 D-7A I-4A I-4A I-4A I-4A I-4A 303 1-63-2 D-2 I-4A I-4A I-1A I-4A I-4A 303 1-63-4 D-7A I-1A I-1A I-1A I-1A I-1A 303 1-65-4 D-2 I-4A I-4A I-4A I-4A I-4A 303 1-66-1 D-7A I-4A - I-4A I-4A - 303 4-49-0 D-6 I-4A I-4A I-4A I-4A I-4A 303 4-49-0 - - I-4A I-4A I-4A I-4A 401 4-78-0 T-2 T-2 T-2 T-2 T-2 T-2 402 1-58-1 D-7A I-4A I-4A I-4A I-4A I-4A 402 1-70-2 D-2 I-4A I-1A I-1A I-1A I-1A 402 1-70-4 D-2 I-4A I-4A I-4A I-4A I-4A 402 1-78-2 D-2 I-4A I-1A I-4A I-1A I-4A 402 1-78-4 D-2 I-4A I-4A I-4A I-4A I-1A
402 3-68-0 D-2 I-4A I-1A I-1A I-4A I-4A
403 3-72-1 - - - - - - See General Note 1 403 3-72-2 - - - - - -
403 3-82-0 D-2 I-4A I-4A I-4A I-4A I-4A
DATE:
DATE:
SHEET 5B
Escape Trunk Main Machinery Room
Stateroom (2) Centerboard Trunk
Oceanographic Winch Room Sci/Bosn Stores
LIST OF COMPARTMENTS (BY MODULE)
MODULE COMPT # DESIGNATION
SURFACE SYSTEM
REMARKS
Fuel Tank See General Note 1 Seachest Seachest
Engineer's Operating Station Passage
Chemistry Lab Access
CG Locker Fish Lab/ Wet Lab
Trash Room Scientific Freezer
Controlled Environment Rm Scientist Ready Room
Water Closet
Fish Lab/ Wet Lab
Hazmat/ Paint Locker
Main Machinery Room MMR Sup and Exh Trunk
Bossing (Skeg)
Oceanographic Winch Room Sci/Bosn Stores
Scientific hazmat Locker Ready Room Deck Locker
REV
BABS APRV:
DT #5P Fuel Oil See General Note 1
USCG APRV:
Trawl Winch Room Sci/Bosn Stores
DT #5S Fuel Oil
SCALE: NONE
SIZE
A
FSCM CAGE NO
98042
501 01-19-0 D-7A I-6 - - - - 501 01-33-1 D-7A - - - - - 501 01-33-2 D-7A - - - - - 501 01-37-0 D-2 I-6 I-6 I-6 I-6 I-6 501 01-37-2 D-7A - - - - - 501 01-43-1 D-4 - - - - - 501 01-44-1 D-2 I-6 I-6 I-6 I-6 I-6 501 01-47-2 D-7A - - - - - 501 02-37-0 D-8 I-6 - - - - 501 02-37-2 D-8 - - - - - 501 02-39-1 D-8 - - - - - 501 02-45-0 D-8 I-6 - - - - 501 02-45-1 D-8 - - - - - 501 02-46-2 D-8 - - - - - 501 02-47-1 D-4 I-6 - - - - 501 02-50-3 D-8 - - - - - 501 02-53-2 D-3 I-6 I-6 I-6 I-6 I-6 501 1-51-2 D-7A I-6 I-6 I-6 I-6 I-6 501 4-39-0 501 02-50-1 - I-6 - - - - 502 01-10-0 D-2 I-6 I-6 I-6 I-6 I-6 502 01-14-0 D-1 E-4 E-4 E-4 E-4 E-4 502 01-19-0 D-7A I-6 - - - - 502 02-22-0 T-4 T-4 T-4 T-4 T-4 T-4 502 02-29-0 D-8 - - - - - 502 01-10-1 D-3 I-6 I-6 I-6 I-6 I-6 502 01-12-1 D-3 I-6 I-6 I-6 I-6 I-6 502 01-19-1 D-7A - - - - - 502 01-28-1 D-7A I-6 - - - - 502 01-31-1 D-2 I-6 - - - - 502 01-10-2 D-2 I-6 I-6 I-6 I-6 I-6 502 01-19-2 D-7A - - - - - 502 01-24-2 D-7A - - - - - 502 01-28-2 D-7A - - - - -
DATE:
DATE:
SHEET 5C
See General Note 9Toilet
See General Note 8
See General Note 8
Passage
Stateroom (2)
DC Locker See General Note 8
Passage See General Note 8 Roll Stabilization Tank See General Note 8
StateRoom (2) See General Note 8 Dive Locker See General Note 9
LIST OF COMPARTMENTS (BY MODULE)
MODULE COMPT # DESIGNATION SURFACE SYSTEM REMARKS
Passage See General Note 8 Stateroom (2) See General Note 8 Stateroom (2) See General Note 8
Fan Room see General Note 9 Office Suite See General Note 8
Side Sampling Control Booth See General Note 8
ET Shop See General Note 8 Passage See General Note 8
Stateroom (2) See General Note 8 Stateroom Sr Cmd Officer See General Note 8
CG Locker See General Note 8 Stateroom (2) See General Note 8
Centerboard Trunk See General Note 9
Stateroom (2) See General Note 8 Linen Locker See General Note 8
Hospital See General Note 8
Linen Locker See General Note 8 Refrigeration Machinery See General Note 8
CO2 Room See General Note 8
CG Locker
Deck Locker See General Note 9 Lounge & Conference Room See General Note 8
See General Note 8
DC Locker See General Nore 9 Access See General Note 8
REV
BABS APRV:
SCALE: NONE
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Stateroom (2) See General Note 8 Stateroom (2) See General Note 8
USCG APRV:
502 2-16-2 D-8 I-4 I-6 I-6 I-4 I-6 502 02-29-1 D-8 - - - - - 502 02-29-2 D-8 - - - - - 503 01-54-0 D-2 I-6 I-6 I-6 I-6 I-6 505 4-49-0 - - - - - - 506 03-34-0 D-8 I-6 I-6 I-6 I-6 I-6 507 - E-4 E-4 E-4 E-4 E-4
DATE:
DATE:
SHEET 5D
LIST OF COMPARTMENTS (BY MODULE)
MODULE COMPT # DESIGNATION SURFACE SYSTEM REMARKS
Access See General Note 9 Stateroom Chief Scientist See General Note 8 Stateroom Chief Engineer See General Note 8
Emergency Generator Room See General Note 9 MMR Sup & Exh Trunk See General Note 8
Bridge See General Note 9 Mast
USCG APRV:
REV
BABS APRV:
SCALE: NONE
SIZE
A
FSCM CAGE NO
98042
MIN MAX Nozzle N13 Green FULL 4.0 3.0 4 Hr 3 Mo X 0.021" N14 Terracotta FULL 8.0 5.0 8 Hr - X 0.021" N47 FULL 8.0 5.0 9 Hr - X 0.021"
Touch Hard 78% Powder 4 Hr 6 Hr 66% Part B 2 Hr 16 Hr
DATE:
DATE:
SHEET 6
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Non skid grit as recommended by PPG Protective and Marine Coatings is to be added to the finish coat on all deck surfaces except for the trawlway and trawlway inclined ramp.
Notes:
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
1:1 8 Hr 99 32 120 1:1 3 Hr 85 40 120
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F
PAINT SYSTEM "D-1"
212 148
AREA: All exterior steel decks (150 mm up on vertical surfaces), house tops, trawlway, trawlway ramp, exterior hatch covers/coamings, foundations, deck fittings, and inboard side of bulwarks.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to 1st coat Blast damaged areas near white to SSPC- SP10 finish. Sand sweep remaining area to SSPC- SP7 finish.
Dimetcote 302H 417 292 Amercoat 385 212 148
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Brush Roller Conv.
Spray
Airless SprayTheoretical Practical
Application Method Airless Spray
Fan
APPLICATION
Humidity
90%
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
Amercoat 385
Part Number
Dimetcote 302H Amercoat 385
PRODUCT INFORMATION
Mid Graphite
Gray
50%
MIN MAX
N17 Dark Gray FULL 9.0 6.0 8 Hr - X 0.021" N14 Terracotta FULL 9.0 6.0 8 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr
DATE:
DATE:
SHEET 7
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° F
1:1 3 Hr
AREA: Exposed interior steel decks (150 mm up on vertical surfaces) in auxiliary machinery and service spaces, workshops, storerooms, deck lockers and similar spaces.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to 1st under coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
Application Method Airless Spray
Fan Airless Spray
Amercoat 385 176 124 Amercoat 385 176 124
Brush Roller Conv.
Spray
SYSTEM
INFORMATION
COLOR
Remarks: Notes:
PRODUCT INFORMATION
Amercoat 385 85 40 120
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
APPLICATION
Humidity
MAXMIN
PAINT SYSTEM "D-2"
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
NUMBER
N14 Terracotta FULL 9.0 6.0 8 Hr - X 0.021" N17 Dark Grey FULL 9.0 6.0 8 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr
DATE:
DATE:
SHEET 8
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Non skid grit as recommended by PPG Protective and Marine Coatings is to be added to the finish coat. Notes:
85 40 120
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
APPLICATION
Humidity
MAXMIN
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° F
1:1 3 Hr
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical Amercoat 385 176 124
SYSTEM
INFORMATION
Amercoat 385 176 124
Brush Roller Conv.
Spray
Airless Spray
Application Method Airless Spray
Fan
COLOR
PAINT SYSTEM "D-3"
PART
NUMBER
AREA: All aluminum exterior decks (150 mm up on vertical surfaces) house tops, exterior hatch covers, foundations, deck fittings and inboard side of bulwarks.
SURFACE PREPARATION:
1) Prep prior to 1st under coat: Sandsweep SSPC-SP-7
PRODUCT INFORMATION
Amercoat 385
N17 Dark Grey FULL 9.0 6.0 8 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr
DATE:
DATE:
SHEET 9
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Non skid grit as recommended by PPG Protective and Marine Coatings is to be added to the finish coat. Notes:
85 40 1203 HrAmercoat 385 1:1
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° FPRODUCT INFORMATION
PAINT SYSTEM "D-4"
Amercoat 385 176 124
Brush Roller Conv.
Spray
Airless Spray
AREA: All aluminum interior decks (150 mm up on vertical surfaces)
SURFACE PREPARATION:
1) Power wash/degrease @ 344.7 bar (5000 PSI).
2) Prep prior to 1st under coat: Sandsweep SSPC-SP-7
PART
NUMBER
Application Method Airless Spray
Fan Amercoat 385 176 124
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
APPLICATION
Humidity
MIN MAX
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
N14 Terracotta FULL 8.0 5.0 8 Hr - X 0.021" N5 Black FULL 4.0 2.0 6 Hr - X 0.021"
Touch Hard 78% Powder 4 Hr 6 Hr 66% Part B 2 Hr 16 Hr 56% Part B 2 Hr 8 Hr
DATE:
DATE:
SHEET 10
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Notes:
40 120 1:1 3 Hr 85 40 120 -
32 120
Flash Point (degrees F)
Air Temperature (degrees F)
MIN MAX
APPLICATION
Humidity
MAXMIN
50% 90%
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F
1:1 8 Hr
Amercoat 229T 449 337
PAINT SYSTEM "D-5"
Amercoat 385 212 148
Brush Roller Conv.
Spray
Airless Spray
AREA: Steel deck machinery, electric brakes, motor housing exteriors, deck mounted chocks/cleats/bitts and fairleads.
SURFACE PREPARATION: 1) Material is to be blasted near white to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
PART
NUMBER
Application Method Airless Spray
Fan Dimetcote 302H 417 292
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
Remarks: All required surface preparation is for structural elements prior to final assembly.
PRODUCT INFORMATION
Dimetcote 302H Amercoat 385
Amercoat 299T
4:1 6 Hr 80
N17 Dark Grey FULL 9.0 6.0 8 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr
DATE:
DATE:
SHEET 11
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Notes:
1:1 3 Hr 85 40 120
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
APPLICATION
Humidity
MIN MAX
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° FPRODUCT INFORMATION
PAINT SYSTEM "D-6"
Amercoat 385 176 124
Brush Roller Conv.
Spray
Airless Spray
AREA: Walking surfaces of floor plates, grates, decks, and platforms in main machinery spaces.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to under coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
3) Prep prior to finish coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
Application Method Airless Spray
Fan Amercoat 385 176 124
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
N22 Terracotta FULL 3.5 2.0 8 Hr 24 Hr X 0.017"
Touch Hard 60% N/A 2 Hr 6 Hr
DATE:
DATE:
SHEET 12
REV
BABS APRV:
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F
PRODUCT INFORMATION
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Notes:
PAINT SYSTEM "D-7"
Brush Roller Conv.
Spray
Airless Spray
AREA: Unexposed steel decks which receive deck covering or under enclosed furniture or equipment.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
PART
NUMBER
Application Method Airless Spray
Fan Amercoat 5105 481 337
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
Amercoat 5105
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
APPLICATION
Humidity
MIN
MAX
N/A - 100 40 110
N14 Terracotta FULL 8.0 5.0 8 Hr X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr
DATE:
DATE:
SHEET 12ASCALE: NONE
Remarks: Notes:
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
-Amercoat 385 N/A 3 Hr 85 40 120 -
Flash Point (degrees F)
APPLICATION
Temperature (degrees F) Humidity
MIN MAX MIN MAX
PRODUCT INFORMATION
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F
Theoretical Practical Fan Amercoat 385 212 148
Overcoat Time @ 70° F
Application Method
Brush Roller Conv.
Spray
Airless Spray
Airless Spray
PAINT SYSTEM "D-7A"
AREA: Unexposed steel decks which receive deck covering or under enclosed furniture or equipment.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
PART
NUMBER
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Touch Hard
DATE:
DATE:
SHEET 13
AREA: Aluminum decks to receive deck covering other than paint. SURFACE PREPARATION:
1) Power wash/degrease @ 344.7 bar (5000 PSI).
2) Prep prior to 1st under coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
Airless Spray
Application Method Airless Spray
Fan
PAINT SYSTEM "D-8"
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical Brush Roller
Conv.
Spray
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
PRODUCT INFORMATION
APPLICATION
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F Humidity
MAX
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Notes:
MIN
N14 Terracotta FULL 8.0 5.0 8 Hr - X 0.021" N3 White FULL 4.0 2.0 6 Hr - X 0.021"
Touch Hard 78% Powder 4 Hr 6 Hr 66% Part B 2 Hr 16 Hr 56% Part B 2 Hr 8 Hr
DATE:
DATE:
SHEET 14
PAINT SYSTEM "E-1"
AREA: Shell exterior from 6.25 meter water line up through turn of gunwale including the outboard side of the bulwarks.
Continued in Remarks
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to 1st under coat: Blast damaged areas near white to SSPC- SP10 finish. Sand sweep remaining area to SSPC- SP7 finish.
PART
NUMBER
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical Brush Roller
Conv.
Spray
Airless Spray
Application Method Airless Spray
Fan
Amercoat 229T 449 337
Dimetcote 302H 417 292 Amercoat 385 212 148
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
PRODUCT INFORMATION
APPLICATION
MAX
90%
Humidity
MIN
50%
40 120 -
1:1 8 Hr 99 32 120 N/A 3 Hr 85 4:1 6 Hr 80 40 120
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Notes:Remarks: Area (continued) Exterior steel deckhouses, vents, overflows, overhead surfaces, deck gear lockers, doors, stanchions, vertical and inclined ladders, handrails, ventilators, bulwark mounted chocks, davits and steel monorails.
Dimetcote 302H
Amercoat 229T
N14 Terracotta FULL 8.0 5.0 8 Hr - X 0.021" N8 Buff FULL 4.0 2.0 6 Hr - X 0.021"
Touch Hard 78% Powder 4 Hr 6 Hr 66% Part B 2 Hr 16 Hr 45% Part B 2 Hr 8 Hr
DATE:
DATE:
SHEET 15
AREA: Steel masts, booms, cranes, “A” frames, gantries, and similar fittings.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to 1st under coat: Blast damaged areas near white to SSPC- SP10 finish. Sand sweep remaining area to SSPC- SP7 finish.
PART
NUMBER
Airless Spray
Application Method Airless Spray
Fan
PAINT SYSTEM "E-2"
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical Dimetcote 302H 417 292 Amercoat 385 212 148
Brush Roller Conv.
Spray
Amercoat 229T 449 337
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
PRODUCT INFORMATION
Dimetcote 302H
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F
APPLICATION
Humidity
MAX
90%
N/A 3 Hr 85 40 120Amercoat 385 Amercoat 229T
1:1 8 Hr 99 32 120
4:1 6 Hr 80 40 120
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Notes:
MIN
50%
N14 Terracotta FULL 8.0 5.0 8 Hr - X 0.021" N3 White FULL 4.0 2.0 6 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr 56% Part B 2 Hr 8 Hr
DATE:
DATE:
SHEET 16
SYSTEM
INFORMATION
COLOR
AREA: All exterior exposed vertical surfaces of the aluminum superstructure including vents, overflows, deck gear lockers, doors, stanchions, vertical and inclined ladders, handrails, ventilators, stack (excluding stack bands) and bulwarks. Also includes the underside of exposed deckheads
SURFACE PREPARATION:
1) Power wash/degrease @ 344.7 bar (5000 PSI).
2) Prep prior to 1st under coat: Sand sweep
PART
NUMBER
Airless Spray
Remarks: Notes:
APPLICATION
Application Method Airless Spray
Fan Amercoat 385 176 124
Amercoat 229T 449 337
Brush Roller Conv.
Spray
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° FPRODUCT INFORMATION
MAX
Humidity
MIN
40 120Amercoat 229T 1:1 3 Hr 85 40 120
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
Amercoat 385
-4:1 6 Hr 80
PAINT SYSTEM "E-3"
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
N14 Terracotta FULL 8.0 5.0 8 Hr 24 Hr X 0.021" N8 Buff FULL 4.0 2.0 6 Hr - X 0.021"
N14 Terracotta FULL 8.0 5.0 8 Hr 24 Hr X 0.021" N5 N7 N9
Touch Hard 66% Part B 2 Hr 16 Hr 56% Part B 2 Hr 8 Hr
DATE:
DATE:
SHEET 17
Remarks: Top band:(Black/N5) 2/15 of stack height, Middle band (light blue/N9) 1/15 of stack height. Bottom band (dark blue/N7) 1/15 of stack height. Bands are to be parallel to baseline and permanently marked. Top band is to be measured from the top of the stack. There is no separation between bands.
Notes:
MAX
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° F Humidity
APPLICATION
Airless Spray Fan
X 0.021"
PAINT SYSTEM "E-4"
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
Application Method
AREA: Aluminum masts, booms, trusses and similar fittings.
Stack Bands.
SURFACE PREPARATION:
1) Power wash/degrease @ 344.7 bar (5000 PSI).
2) Prep prior to 1st under coat: Sand sweep
PART
NUMBER
Amercoat 385 176 124 Amercoat 229T 449 337
Brush Roller Conv.
Spray
Airless Spray
Stack Bands Amercoat 385 176 124
Amercoat 229T See
Remarks
FULL 4.0 2.0 337449
PRODUCT INFORMATION
1:1 3 Hr 85 40 120
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
Amercoat 385
MIN
4:1 6 Hr 80 40 120Amercoat 229T -
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
N22 Terracotta FULL 3.5 2.0 8 Hr 24 Hr X 0.017" N25 White FULL 7.0 3.0 12 Hr - X 0.021"
Touch Hard 60% N/A 2 Hr 6 Hr 45% N/A 1.5 Hr 6 Hr
DATE:
DATE:
SHEET 18
Brush Roller Conv.
Spray
PAINT SYSTEM "I-1"
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical Airless Spray
Fan
AREA: All exposed interior steel bulkheads and overheads in machinery and service spaces, workshops, storerooms, deck lockers and similar spaces, interior railings, stanchions and associated fittings.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to under coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
3) Prep prior to finish coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
Application Method Airless Spray
Amercoat 5105 481 337 Amercoat 5450 241 168
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX MIN
Humidity
APPLICATION
MAX
-Amercoat 5105
N/A - 98 45 100 N/A - 100 40 110
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° FPRODUCT INFORMATION
-Amercoat 5450 -
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
N16 Off White FULL 8.0 5.0 8 Hr 24 Hr X 0.021" N25 White FULL 7.0 3.0 12 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr 45% N/A 1.5 Hr 6 Hr
DATE:
DATE:
SHEET 18ASCALE: NONE
Remarks: Notes:
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
Amercoat 5450 N/A - 98 45 100 - - Amercoat 385 N/A 3 Hr 85 40 120 -
Flash Point (degrees F)
APPLICATION
Temperature (degrees F) Humidity
MIN MAX MIN MAX
PRODUCT INFORMATION
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° F
Amercoat 5450 241 168
Theoretical Practical Fan Amercoat 385 212 148
Overcoat Time @ 70° F
Application Method
Brush Roller Conv.
Spray
Airless Spray
Airless Spray
PAINT SYSTEM "I-1A"
AREA: All exposed interior steel bulkheads and overheads in machinery and service spaces, workshops, storerooms, deck lockers and similar spaces, interior railings, stanchions and associated fittings.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to under coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
3) Prep prior to finish coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
N25 White FULL 7.0 3.0 12 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr 45% N/A 2 Hr 12 Hr
DATE:
DATE:
SHEET 19
Brush Roller Conv.
Spray
PAINT SYSTEM "I-2"
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
Application Method Airless Spray
Fan
AREA: Exposed interior aluminum bulkheads and overheads. SURFACE PREPARATION:
1) Power wash/degrease @ 344.7 bar (5000 PSI).
2) Prep prior to 1st under coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
Airless Spray
Amercoat 385 212 148 Amercoat 5450 241 168
MIN
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° FPRODUCT INFORMATION
APPLICATION
Humidity
MAX
Amercoat 5450 1:1 3 Hr 85 40 120
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
Amercoat 385
-N/A N/A 98 45 100
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
N22 Terracotta FULL 3.5 2.0 8 Hr 24 Hr X 0.17 N21 Black FULL 7.0 3.0 12 Hr - X 0.021"
Touch Hard 60% N/A 2 Hr 6 Hr 59% N/A 1.5 Hr 6 Hr
DATE:
DATE:
SHEET 20
Brush Roller Conv.
Spray
PAINT SYSTEM "I-3"
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
Application Method Airless Spray
Fan
AREA: All interior steel ladders outside of tanks. SURFACE PREPARATION: Blast to SSPC-SP 7 prior to 1st coat.
PART
NUMBER
Airless Spray
Amercoat 5105 481 337 Amercoat 5450 241 168
MIN
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° FPRODUCT INFORMATION
APPLICATION
Humidity
MAX
Amercoat 5450 N/A - 100 40 110
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
Amercoat 5105
-N/A - 108 45 100
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
N21 Black FULL 7.0 3.0 12 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr 59% N/A 1.5 Hr 6 Hr
DATE:
DATE:
SHEET 20ASCALE: NONE
Remarks: Notes:
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
Amercoat 5450 N/A - 108 45 100 - - Amercoat 385 N/A 3 Hr 85 40 120 -
Flash Point (degrees F)
APPLICATION
Temperature (degrees F) Humidity
MIN MAX MIN MAX
PRODUCT INFORMATION
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° F
Amercoat 5450 241 168
Theoretical Practical Fan Amercoat 385 212 148
Overcoat Time @ 70° F
Application Method
Brush Roller Conv.
Spray
Airless Spray
Airless Spray
PAINT SYSTEM "I-3A"
AREA: All interior steel ladders outside of tanks. SURFACE PREPARATION: Blast to SSPC-SP 7 prior to 1st coat.
PART
NUMBER
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
N25 White FULL 7.0 3.0 12 Hr - X 0.021" N36 Buff FULL 5.0 3.0 3 Hr - X 0.021"
Touch Hard 45% N/A 1.5 6
DATE:
DATE:
SHEET 21
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Notes:Remarks: Amercoat 5450 is only to be applied on top of insulation. Amercoat 5450 shall not be applied to type II acoustic insulation.
N/A - 98 45 100
Temperature (degrees F)
MIN MAX
APPLICATION
Humidity
MAX
MIN
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° FPRODUCT INFORMATION
Amercoat 5450
Flash Point (degrees F)
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical Amercoat 5450 241 168 Sigmacoat 435 266 186
Brush Roller Conv.
Spray
AREA: Unexposed steel structure behind insulation and/or joiner panels.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to finish coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
PAINT SYSTEM "I-4"
Airless Spray
Application Method Airless Spray
Fan
N36 Buff FULL 5.0 3.0 3 Hr - X 0.021"
Touch Hard 66% Part B 2 Hr 16 Hr 45% N/A 1.5 6
DATE:
DATE:
SHEET 21ASCALE: NONE
Remarks: Amercoat 5450 is only to be applied on top of insulation. Amercoat 5450 shall not be applied to type II acoustic insulation.
Notes:
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
Amercoat 5450 N/A - 98 45 100 - - Amercoat 385 N/A 3 Hr 85 40 120 -
Flash Point (degrees F)
APPLICATION
Temperature (degrees F) Humidity
MIN MAX MIN MAX
PRODUCT INFORMATION
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° F
Sigmacoat 435 266 186
Theoretical Practical Fan Amercoat 385 212 148
Overcoat Time @ 70° F
Application Method
Brush Roller Conv.
Spray
Airless Spray
Airless Spray
PAINT SYSTEM "I-4A"
AREA: Unexposed steel structure behind insulation and/or joiner panels.
SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to finish coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
N13 Green FULL 4.0 3.0 4 Hr 6 Mo X 0.021" N14 Terracotta FULL 9.0 6.0 8 Hr 24 Hr X 0.021"
Touch Hard 78% Part B 4 Hr 6 Hr 66% N/A 2 Hr 16 Hr
DATE:
DATE:
SHEET 22
APPLICATION
Humidity
MAX
90%
REV
BABS APRV:
SCALE: NONE
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
Remarks: Notes:
N/A 3 Hr 85 40 120Amercoat 385 -
MIN
50%99 32 120
Flash Point (degrees F)
Temperature (degrees F)
MIN MAX
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time
(DFT)
(6 mil) at 70° F
1:1 8 Hr
PRODUCT INFORMATION
Dimetcote 302H
Dimetcote 302H 417 292 Amercoat 385 176 124
Brush Roller Conv.
Spray
AREA: Bilges SURFACE PREPARATION: 1) Material is to be blasted in wheelabrator to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
2) Prep prior to under coat: Wire brush damaged areas and wipe down entire area with a mild detergent and rinse.
PART
NUMBER
PAINT SYSTEM "I-5"
Airless Spray
Application Method
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
N25 White FULL 7.0 3.0 12 Hr - X 0.021"
Touch Hard 59% N/A 1.5 Hr 6 Hr
DATE:
DATE:
SHEET 23SCALE: NONE
Remarks: Notes:
USCG APRV:
SIZE
A
FSCM CAGE NO
98042
DRAWING NO.
FSV6-631-01
REV
BABS APRV:
-Amercoat 5450 N/A - 108 45 100 -
Flash Point (degrees F)
APPLICATION
Temperature (degrees F) Humidity
MIN MAX MIN MAX
PRODUCT INFORMATION
VOLUME
SOLIDS
CURING
AGENT
Mixed Ratio Base:Cure
Pot Life at 70° F
Drying time at 70° F
Theoretical Practical Fan Amercoat 5450 241 168
PAINT SYSTEM "I-6"
Overcoat Time @ 70° F
Application Method
Brush Roller Conv.
Spray
Airless Spray
Airless Spray
AREA: Exposed insulation in way of aluminum structure, but not type II acoustic insulation.
SURFACE PREPARATION: Wipe clean and allow to dry
PART
NUMBER
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
N14 Terracotta FULL 8.0 5.0 8 Hr - X 0.021" N5 Black FULL 4.0 2.0 6 Hr - X 0.021"
Touch Hard 78% Powder 4 Hr 6 Hr 66% Part B 2 Hr 16 Hr 56% Part B 2 Hr 8 Hr
DATE:
DATE:
SHEET 24
Brush Roller Conv.
Spray
PAINT SYSTEM "M-1"
SYSTEM
INFORMATION
COLOR
TYPE
COAT
WFT
MILS
DFT
MILS
Spread Rate @ Spec.
DFT Sq. Ft. per coat
Overcoat Time @ 70° F
Theoretical Practical
Application Method Airless Spray
Fan
AREA: Anchor SURFACE PREPARATION: 1) Material is to be blasted near white to remove mill scale and oxidation. Any material not suitable for the wheelabrator is to be hand blasted. Blasting is to be finished to specification SSPC-SP10. After blasting all material is to be coated with P/N N23 - International Interplace 937 (Grey) Primer.
PART
NUMBER
Airless Spray
Amercoat 229T 449 337
Dimetcote 302H 417 292 Amercoat 385 212 148
MIN
50%
VOLUME
SOLIDS
CURING
A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .