FSS-PWS-D-TE-D02.01(Hmstd-Bldg600).pdf

PDF 3 MB Posted

Attached to
Facility Support Services (Consolidated) Federal contract opportunity
Solicitation number
W91QEX-24-R-0002
Issued by
Department of the Army Materiel Command Army Contracting Command

About this file

This document includes a technical exhibit outlining facility support service requirements and a related federal contract opportunity notice. The technical exhibit provides floor plan details and furniture layouts for two levels totaling over 54,000 square feet within Homestead Building 600 requiring custodial services. Services include carpet and hard floor cleaning along with furniture arrangement. The related opportunity notice seeks proposals for facility support services at two Army sites in southern Florida encompassing over 900,000 square feet. Services required consist of facility operations and maintenance, custodial work, solid waste management, grounds upkeep, and pest control. The base period of performance is 12 months with four additional 12-month options. The requirement is set aside for 8(a) small businesses. An in-person site visit is scheduled for March 7-8, 2024 with a limit of two attendees per firm who must complete security paperwork by February 27.

View the file

Other files for this federal contract opportunity

Other files attached to Facility Support Services (Consolidated), newest first.
File Type Posted
W91QEX-24-R-0002-0005 Extend Submission (KO).pdf PDF
FSS-PWS-A-TE-A03-A03-D.1.2(EstWkLd-Hmstd)20240409.pdf PDF
W91QEX-24-R-0002-0003 Gvt Responses_Update Exhib.pdf PDF
MiamiFSS-PWS-F-3.0 (404-Grds)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A03.02(EstWkLd-CPFF-DMO+PMO)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A06 (Deliverables)20240327.pdf PDF
MiamiFSS-PWS-D-TE-D02.02ARS(SOCSOUTH ARS Bldg736)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A03.03(EstWkLd-CPFF-OWO)20240327.pdf PDF
W91QEX-24-R-0002-0002 Extend Due Date_Update POP.pdf PDF
W91QEX-24-R-0002-0001 Extend Submission_Add WD.pdf PDF
FSS-PWS-D-TE-D01.01(Doral-Bldg1).pdf PDF
FSS-PWS-K-TE-K03.02 (Equip-HWH-Hmstd).pdf PDF
FSS-PWS-K-TE-K04(ChillerDailyLog).pdf PDF
FSS-PWS-K-TE-K02.02 (Equip-ACPlant-Hmstd).pdf PDF
FSS-PWS-A-TE-A02.02 (PMEqpList-Doral).pdf PDF
FSS-PWS-D-TE-D01.01ARS(SOUTHCOM ARS Bldg1).pdf PDF
FSS-PWS-D-TE-D01.04ARS(USAG-Miami ARS Bldg4,5,6).pdf PDF
FSS-PWS-H-TE-H01.02(FacilityList-Hmstd).pdf PDF
FSS-PWS-A-TE-A01.01 (InstMaps-Sites).pdf PDF
FSS-PWS-H-TE-H08.01(StormWater-Doral).pdf PDF
FSS-PWS-H-TE-H07.01(ExteriorLighting-DoralSite).pdf PDF
FSS-PWS-H-TE-H07.02(ExteriorLighting-HmstdSite).pdf PDF
FSS-PWS-D-TE-D01.05(Doral-Bldg9).pdf PDF
FSS-PWS-D-TE-D01.04(Doral-Bldgs4,5,6).pdf PDF
FSS-PWS-E-TE-E02 (SolidWaste-Hmstd).pdf PDF
FSS-PWS-A-TE-A01.02 (InstMaps-Sites-wFacilities).pdf PDF
FSS-PWS-K-TE-K03.01 (Equip-HWH-Doral).pdf PDF
FSS-PWS-K-TE-K02.01 (Equip-ACPlant-Doral).pdf PDF
FSS-PWS-D-TE-D01.07(Doral-ExtTrash).pdf PDF
FSS-PWS-D-TE-D01.05ARS(USAG-Miami ARS Bldg9).pdf PDF
FSS-PWS-D-TE-D01.07ARS(USAG-Miami ARS ExtWaste).pdf PDF
FSS-PWS-F-TE-F01.02 (GrdsWkLd-Doral).pdf PDF
FSS-PWS-H-TE-H02.02(PMEqpList-Hmstd).pdf PDF
FSS-PWS-F-TE-F02.02 (GrdsWkLd-Hmstd).pdf PDF
FSS-PWS-D-TE-D02.02ARS(SOCSOUTH ARS Bldg736).pdf PDF
FSS-PWS-A-TE-A04.01 (DD254-Doral).pdf PDF
FSS-PWS-D-TE-D02.03ARS(SOCSOUTH ARS Bldg741).pdf PDF
W91QEX-24-R-0002 Facility Support Services.pdf PDF
FSS-PWS-H-TE-H05(BUILDER-References).pdf PDF
FSS-PWS-F-TE-F01.04 (GrdsIrrSyst-Doral).pdf PDF
FSS-PWS-H-TE-H08.02(StormWater-Hmstd).pdf PDF
FSS-PWS-H-TE-H09.01(Irrigation-DoralSite).pdf PDF
FSS-PWS-D-TE-D02.03(Hmstd-Bldg741).pdf PDF
FSS-PWS-D-TE-D01.03(Doral-Bldg3).pdf PDF
FSS-PWS-D-TE-D02.02(Hmstd-Bldg736).pdf PDF
FSS-PWS-A-TE-A02.01 (PMChecklist).pdf PDF
FSS-PWS-A-TE-A02.02 (PMEqpList-Hmstd).pdf PDF
FSS-PWS-H-TE-H02.01(PMEqpList-Doral).pdf PDF
FSS-PWS-D-TE-D00(BaselineServiceLevels).pdf PDF
FSS-PWS-D-TE-D01.03ARS(USAG-Miami ARS Bldg3).pdf PDF
Show all 50

Facility Support Services (Consolidated) has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C USAG-Miami FSS, Annex D (Custodial Services) Technical Exhibit D02.01 - Homestead Bldg 600 SOCSOUTH HQ

Level 1 [26,185 SF, Serviced Area ONLY] Carpet Floor= 13,980 SF

Hard Floor = 12,205 SF Security Clearance Requirement - SECRET*

.3 fi

CANOP

IC-JOL.1-1:i=1cu

WEAPONS

VAULT

(18'x211

FURNITURE CODE KEY

SYMBOL DESCRIPTION

C SEATING

CR CREDENZA

D DESKS

L LECTERN

s WORKSTATIONS

ST STORAGE

T TABLES

WB WHITEBOARDS

J1.•W>

ROO•

B f H'l

VEST

Main Entry / Lobby

112TH

Cl STOR

FF&E NOTES:

1. WHITEBOARDS (WBO SHOULD BE MOUNTED 7'-0"

A.F.F. TO THE TOP OF THE FRAME.

2. THE DIMENSIONS AT THE TABLES INDICATE THE

LOCATION OF THE BASES OR LEGS THAT WILL

ACCEPT VOICE, DATA ANO/OR POWER FROM A

JUNCTION BOX IN THE FLOOR. TABLES T-9A,

T9-B ANO T-11 WILL NEED TO BE VERIFIED \1/ITH

THE SHOP DRAWINGS SINCE THEY ARE CUSTOM. 3. ALL JUNCTION BOX AND OUTLET LOCATIONS

SHOULD BE VERIFIED WITH THE FURNITURE

DEALER PRIOR TO INSTAllATION.

4. NUMBER Of BASE FEEDS IN THE SYSTEMS

H

PANELS SHOULD BE VERIFIED WITH THE "E"

DRAWINGS TO ENSURE THE PROPER NUMBER OF

CIRCUrTS AND CORRECT INTERFACE \1/ITH THE BUILDING. PRIOR TO ROUGH-IN, THIS INfORMATION

SHOULD BE REVIEWED AND CONFIRMED WITH THE

USER AND THE FlJRNrTURE DEALER.

C ufi : l:: :

s ���� STAIR!l3: : : : : l:: : : l

�I I 111:11

D

G�

5. NUMBER OF ACCESSIBLE POINTS INTO THE

SYSTEMS PANELS FOR VOICE & DATA CABLES.

WITH CONSIDERATION TO FILL AND RADIUS BEND,

CAN BE FOUND ON THE i' SHEETS. PRIOR TO

ROUGH-IN, THIS INFORMATION SHOULD BE

REVEWED AND CONFIRMED WITH THE USER AND

THE FURNITURE DEALER .

6. GC TO PROVIDE BLOCKING AS REQUIRED FOR

MOUNTING OF MEDIA EQUIPMENT ANO COORDINATE

CONNECTION REQUIREMENTS FOR POWER AND

7. REFER TO THE ELECTRICAL ANO COMMUNICATION

DRA\\'INGS FOR WALL MOUNTING HEIGHTS OF

AUDIO VISUAL EQUIPMENT.

I)

-l,:-,..1

( �1l

I j l EQUIP

AR!cA I $f0ff I

I

ID]

- - - - - - - - - - - r'CAl'lOPY

�IT,.-/

r, □ ll.

-, I I ,_/ I / �---------- I

I I I I I I

I I

I d I I

OD DD OD OD ..J01

t j I I

IOI LIU DD OD .JD1

: b d I I I :

1D -□□-OD 001

UI L

i

N ---f, I I I ou

ER �i _.� DD DD□□ :m1 AND SE r, , f� I I CA • S •, .. 1, \' \ '

J

Fitness Area

•'IULTI-PURPOSE

f Owl.. 1:: R

� u ...... �"'11' •·/1'-:l..a.•� fffllln liiliil US Anny Corps of Ellgineers MobileDislrict

�f �-

<C

� 0

I

.-. CORROCR ·-� - - - -- --,L...T _ -- - -�-- -- -- � '"

// 1 ·,\ ,,,_ B

I I Bldg 600 Common Zone I 28,055 ]

I Par.i 3.2.2.1.1 and 3.2.2. t.2.1 I

Bldg 600 Command G q> / Medical Zone I 2,750 SF ] I Para 3.2.2.1.1 and 3.2.2.1.2.2] l llldg 600 }p�ia I Se.,u rit)· Zone I O SF l

I Para 3.2.2.1.L and 3.2.2.1.2.J I

:\0 SCHJ:DUT .F.D CUSTODIA I. SERVICES

Uility / Storage S1>arc I 9,030 SF I

BR= Break Room [ 1] CC= Custcxlial Closet ( 3) CR= Conference Room [ 5 J E = Elevator I 4]

(��ol1:-�;;I

CANOPY

ID-I 04.2 - - - - .

lj-1044

T

§ u:

z "' 5 w 1! ~ ci UJ U) �

�� ��q i�:ii:� i �� i 1·f �� � o!!s o"s "'

Ii 58 ;j ...

z

0::: :5 0 0..

.....JwLL 0:::

=:) F = Drinking Fountain [ 8] __________ ...,..., ........ ___ .,., K = Kitchen IO l ui I:= 0::: z Li::: 0:::

PB= Private Bath/Shower [ 0] RR·M = Rest Room Men [ 3] RR-W = Rest Room Women [ 3 J

LL

LR/S = Locker/Shower Rm Men ( 1] .o __________ ..,......,._....,.....,. ___ LR/S-W = Locker/Shower Rm Women [ 1 J � ..._ ____ ___, NORTH

S = Stairwell [ 8] .u __ ___ _ T /R = Consolidated Trash/Recycle Receptacles [ 10 JS l ll?S _UU< un11u1�L l'LP,\j --, 10·-s· 5'-4' o· 10'-8" 21•-4• � s

Sheet Refere,,ce Numllar:

ID-104 SCALE: 3/32" = 1'-o· co

" L

.3 fi

USAG-Miami FSS, Annex D (Custodial Services) Technical Exhibit D02.01 - Homestead Bldg 600 SOCSOUTH HQ

Level 2 [27,955 SF, Serviced Area ONLY] Carpet Floor= 25,635 SF Hard Floor = 2,320 SF

Security Clearance Requirement - SECRET"

''ECll

MAm ElfC

1' ",.

_ehRR

,J

./ DN s

STAR#1

�p

El.EV

LOOBY

D

T/R

CORR

as:

CT@

IC-105.

,=====!E:====a ����==l�=

OEPLOYAflLE lRAlNNG

,f-l> r-�

1tt ��,:l oi rJ (}

JiWORK

AAFA

FURNITURE CODE KEY

SYMBOL DESCRIPTION

C SEATING

CR CREDENZA

D DESKS

L LECTERN

s WORKSTATIONS

ST STORAGE

T TABLES

WB WHITEBOARDS

H

CC!.�C

u] CCISTOR

VEST\,.

� �tEO!"-

"'--... SP,ce

FF&ENOTES:

1. WHITEBOARDS (WBO SHOULD BE �OUNTED 7'-0"

A.F.F. TO TllE TOP OF THE FRAME.

2. THE Dl�ENSIONS AT THE TABLES INDICATE THE

LOCATION OF THE BASES OR LEGS THAT WILL

ACCEPT VOICE, DATA AND/OR POWER FROM A

JUNCTION BOX IN THE FLOOR, TABLES T-9A,

T9-B AND T-1 I WILL NEED TO BE VERIFIED WITH

THE SHOP DRAWINGS SINCE THEY ARE CUSTOM.

3. ALL JUNCTION BOX AND OUTLET LOCATIONS

SHOULD BE VERIFIED WITH THE FURNITURE

DEALER PRIOR TO INSTALIATION.

4. NUI.IBER OF BASE FEEDS IN THE SYSTEMS

PANELS SHOULD BE VERIFIED WITH THE "E"

DRAWINGS TO ENSURE THE PROPER NUMBER OF

CIRCUITS AND CORRECT INTERFACE \VITH THE

BUILDING. PRIOR TO ROUGH-IN, THIS INFORMATION

SHOULD BE REVIEWED AND CONFIRMED WITH THE

USER AND THE FURNITURE DEALER.

C r,:_

5. NUMBER OF ACCESSIBLE POINTS INTO THE

SYSTEMS PANELS FOR VOICE & DATA CABLES,

\ll'ITH CONSIDERATION TO FILL AND RADIUS BEND, CAN BE FOUND ON THE 1" SHEETS. PRIOR TO

ROUGH-IN. THIS INFOR�ATION SHOULD BE

REVIEWED AND CONFIRMED WITH THE USER AND

THE FURNITURE DEALER

6. GC TO PROVIDE BLOCKING AS REQUIRED FOR

MOUNTING OF i.lEDIA EQUIPMENT AND COORDINATE

CONNECTION REQUIREMENTS FOR POWER AND

7. REFER TO THE ELECTRICAL AND COMI.IUNICATION

DRAWINGS FOR WALL MOUNTING HEIGHTS OF

AUDIO VISUAL EQUIPMENT.

I)

TR

tlo\Th

CENTER

Q--(J

6--b

CORR

F 2018 j

'i ·Yo 1nD sa.'11 ly LI

SUP\;R,i

AIS

WORK

T/R

Bldg 6/IO Common Zone f 32,200 SF l I Pn111 3.2.2.1.1 and 3.2.2.1.2.1 I

Rldg 600 Command Grp / Medical Zone f N/A I I Para 3.2.2.1.1 and 3.2.2.1.2.21

Bldg 600 Special Sern,i;ity ;lo,ne I 6?0 St' J

Jf Pam 3.2.2.1.1 and 3.2.'2.1.2.3 f

NO SCHLDt:LED CUSTOOL,\,L SERVICES

Utility/ Storage Space f 6,94!i SF I

STOR

f

ELfC f Ow L- 1:: R i.. . ....-�"'11' •·/1'-:l..a.•�

-�I][] """' \, -< []El

PROOUCTletl lJOll

C,-' 05.2

ID-105.L

BR = Break Room [ 1 I CC= Custodial Closet [ 1] CR= Conference Room I 5 I E = Elevator [ 3 I F = Drinking Fountain ( 4 I K = Kitchen IO l PB= Private Bath/Shower I O I RR-M = Rest Room Men [ 2] RR-W = Rest Room Women [ 2] S = Stairwell ( 31 T/R = Consolidated Trash/Recycle Receptacles I 10 l

SLCCI\Jl; I LUO!? I L_; , \I \II'-' \L 10'-a" 5'-4" o· 10' -8" 21-4"

SCALE: 3/32" = 1'-0"

LO

w z t-s cD fffllln liiliil US Anny Corps of Ellgineers MobileDislrict

�f �-

<C

� 0 i B

§ u:

z"' 5 w 1! ~ ci UJ u;i Jg

�� ��q i �:ii:�

&i' � i �� i 1·f �� � o!!s o!!s "'

Ii ;j58 ...

er: z co j='« o:S�Q "'"'"' 0 Q_ 8ffi9 _J

�i�· l.J_ w Q ::, �

0 er:i�� z��::c:cn o- Oz '-'o:r: wO::'.

�8 (/) ::) � l.J_

Sheel Refere,,ce Numllar:

ID-105

"L fi r, C

US Army Garrison Miami BOS, Attachment 1 (Custodial Services) Technical Exhibit 81 · Homestead Bldg 600 SOCSOUTH HQ Paragraph 3.2.2.1

Level 3 [ 29,855 SF, Serviced Area ONLY] Carpet Floor = 28,045 SF Hard Floor = 1,810 SF

Security Clearance Requirement • SECRET"

.3

- .ti: -.1%..1 D-. 06.3 it:;, c com n n ,;:,-1 C=lil

0 0 D--1 � 0--

7 D--7 � D--7 fi

°" .. O:-ii h q_,· ,�� r-1.

e ,t3, 0-7 � D·7

'\c-)

FUR ITURE CODE KEY

SYMBOL DESCRIPTION

C SEATING

CR CREDENZA

D DESKS

L LECTERN

s WORKSTATIONS

ST STORAGE

T TABLES

WB WHITEBOARDS

'l-.i �=;-{ 0-� e-t

�-l' c"'...i'lt.

)-c;�

H

STOR

CORR

i

/ DN

s ELEV

LOBBY

ELEV

LOBaY n c:r• Q 0 0 __, I __, I k{ k-J

0 0 .. , I .. , I k� k�

FF&E NOTES:

1. WHITEBOARDS (WBO SHOULD BE MOUNTED 7'-0"

AH. TO THE TOP OF THE FRAME.

2. THE DIMENSIONS AT THE TABLES INDICATE THE

LOCATION OF THE BASES OR LEGS THAT \\'ILL

ACCEPT VOICE, DATA AND/OR POWER FROM A

JUNCTION BOX IN THE FLOOR. TABLES T -9A,

T9-B AND T -11 l\'ILL NEED TO BE VERIFIED l\'ITH

THE SHOP DRAWINGS SINCE THEY ARE CUSTOM.

3. ALL JUNCTION BOX AND OUTLET LOCATIONS

S HOULD BE VERIFIED WITH THE FURNITURE

DEALER PRIOR TO INSTALLATION.

4, NUMBER or BASE FEEDS IN THE SYSTEMS

PANELS SHOULD BE VERIFIED WITH THE "E"

DRAWINGS TO ENSURE THE PROPER NUMBER OF

CIRCUITS AND CORRECT INTERFACE WITH THE

BUILDING. PRIOR TO ROUGH-IN, THIS INFORMATION

SHOULD BE REVIEWED AND CONFIRMED WITH THE

USER AND THE FURNITURE DEALER.

C

D

,t> 1:� 0 19 e 1e

T/R

BR ''"'"

T/R

I I ,.., ..-

ID kc::i

5. NUMBER OF ACCESSIBLE POINTS INTO THE

SYSTEMS PANELS FOR VOICE & DATA CABLES,

WITH CONSIDERATION TO FILL AND RADIUS BEND,

CAN BE FOUND ON THE "T" SHEETS. PRIOR TO

ROUGH-IN, THIS INFORMATION SHOULD BE

REVIEWED AND CONFIRMED WITH THE USER ANO

THE FURNITURE DEALER

6. GC TO PROVIDE BLOCKING AS REQUIRED FOR

MOUNTING OF MEDIA EQUIPMENT AND COORDINATE

CONNECTION REQUIREMENTS FOR P0\1/ER AND

7. R F R T H L C RICA AN CO U I A 0

DRAWINGS FOR WALL MOUNTING HEIGHTS OF

AUDIO VISUAL EQUIPMENT.

I) lR

Bldg 60-0 Common Zone [ 17, 4JS s1· J I Para 3.2.2.1.1 and 3.2.2.1.2.1 ]

Bldg 600 Command Grp I l\tcdkal Zone I 6,040 St" J I Para 3.2.2.1.1 and 3,2.2.1.2,21

Bldg 600 S)iecial Security Zone I 11.670 SF I l l'ara 3.2.2.1.1- ,md 3.2.2.1.2.3 J

NO SC:IIEDI ILED C(TSTODIAL SERVICES

Utility I Storage Space 14,710 SI' I rn � LJ7 ,c-u c-

•'-u ----r rrr===::::::::=�t=; (

STO \

f Ow L- 1:: R i.. . ....-�"'11' •·/1'-:l..a.•� fffllln liiliil US Anny Corps of Ellgineers Mobile Dislnct

�f �-

<C

� 0 i

B fAClAS

SERYER

SCICER

SER\OER

Security Clearance Requil'ed SLCRtT, with Go.-crnment Lsrort l �· G-IA'.Cl r�, I ,._, ! ·--.e�,..,1_� c�1�,l�

C·lil

-1C6.2

BR= Break Room ( 3] CC= Custo<lial Closet I 1 J CR= Conference Room ( 8] E = Elevator I 4, Same as level l) F = Drinking Fountain ( 4 J K = Kitchen I O I PB= Private Bath/Shower ( 6] RR-M = Rest Room Men [ 2) RR-W = Rest Room Women [ 2 J S = Stairwell I 3] T /R = Consolidated Trash/Recycle

11 IIT I _QCI? Jl]\]I I IReceptacleS[S)

10'-a" 5'-4" o· 10' -a· 21-4" � sco

_!l " § u:

z "' 5 w 1! ~ ci UJ u;i �

�� ��q i �:ii:�

&i' � i �� i 1 ·f �� � o!!s o!!s "'

Ii ;j58 ...

z co j=' <C O::'. <{ �Q __J """'"' 0 �ffig 0..

!i�· 0 __J w l=>!li LL.

i�� O::'.

;[� O::'. t:::

io§? -zI O::'.

:8 I- ::::)

LL

Refere,,ce Numllar:

ID-106 SCALE: 3/32" = 1'-0"

" L

Slide Number 1
Slide Number 2
Slide Number 3

File details come from the government source that posted it. Updated .