FSS-PWS-D-TE-D02.03ARS(SOCSOUTH ARS Bldg741).pdf

PDF 111 KB Posted

Attached to
Facility Support Services (Consolidated)
Solicitation number
W91QEX-24-R-0002
Issued by

About this file

This document contains a technical exhibit for custodial services and a related federal contract opportunity solicitation. The technical exhibit outlines custodial tasks and frequency requirements for a 17,180 square foot facility requiring secret security clearance. Tasks include restroom, stairway, and drinking fountain cleaning at various frequencies. The related solicitation is seeking proposals for facility support services including custodial, maintenance, grounds, waste and pest control at two Army sites totaling over 700,000 square feet. This is an 8(a) small business set-aside issued by the 410th Contracting Support Brigade for the Army Garrison Miami. Site visits will be held on March 7-8, 2024 with a proposal submission deadline of February 27, 2024. The requirement is for a one year base period and four one year options valued at an estimated $30M total.

View the file

Other files

File Type Posted
W91QEX-24-R-0002-0005 Extend Submission (Conformed).pdf PDF
W91QEX-24-R-0002-0005 Extend Submission (KO).pdf PDF
FSS-PWS-A-TE-A03-A03-D.1.2(EstWkLd-Hmstd)20240409.pdf PDF
W91QEX-24-R-0002-0004 Update FAR Clauses (KO).pdf PDF
W91QEX-24-R-0002-0004 Update FAR Clauses (Conformed).pdf PDF
MiamiFSS-PWS-A-TE-A03.03(EstWkLd-CPFF-OWO)20240327.pdf PDF
W91QEX-24-R-0002-0003 Gvt Responses_Update Exhib.pdf PDF
MiamiFSS-PWS-A-TE-A05.01(ContractorSpace-Doral)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A05.02(ContractorSpace-Hmstd)20240327.pdf PDF
MiamiFSS-PWS-D-TE-D02.02ARS(SOCSOUTH ARS Bldg736)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A03.01(EstWkLd-FFP-PMO)20240327.pdf PDF
MiamiFSS-PWS-D-TE-D00(BaselineServiceLevels)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A03(EstWkLd)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A06 (Deliverables)20240327.pdf PDF
MiamiFSS-PWS-A-TE-A03.04(EstWkLd-IDIQ-OWO+PWO)20240327.pdf PDF
W91QEX-24-R-0002-0003 Gvt Responses_Exhib (conformed).pdf PDF
MiamiFSS-PWS-A-TE-A03.02(EstWkLd-CPFF-DMO+PMO)20240327.pdf PDF
MiamiFSS-PWS-F-3.0 (404-Grds)20240327.pdf PDF
W91QEX-24-R-0002-0002 Extend Due Date_Update POP (conformed).pdf PDF
W91QEX-24-R-0002-0002 Extend Due Date_Update POP.pdf PDF
W91QEX-24-R-0002-0001 Extend Submission_Add WD (Conformed).pdf PDF
W91QEX-24-R-0002-0001 Extend Submission_Add WD.pdf PDF
Performance Assessment Questionnaire.pdf PDF
W91QEX-24-R-0002 Facility Support Services.pdf PDF
FSS-PWS-D-TE-D01.03(Doral-Bldg3).pdf PDF
FSS-PWS-F-TE-F02.02 (GrdsWkLd-Hmstd).pdf PDF
FSS-PWS-H-TE-H08.02(StormWater-Hmstd).pdf PDF
FSS-PWS-A-TE-A02.01 (PMChecklist).pdf PDF
FSS-PWS-D-TE-D01.01ARS(SOUTHCOM ARS Bldg1).pdf PDF
HSPD12.pdf PDF
FSS-PWS-D-TE-D02.03(Hmstd-Bldg741).pdf PDF
FSS-PWS-H-TE-H02.01(PMEqpList-Doral).pdf PDF
FSS-PWS-K-TE-K01.01(FacilityList-Doral).pdf PDF
FSS-PWS-H-TE-H01.01(FacilityList-Doral).pdf PDF
FSS-PWS-D-TE-D00(BaselineServiceLevels).pdf PDF
FSS-PWS-F-TE-F01.04 (GrdsIrrSyst-Doral).pdf PDF
FSS-PWS-D-TE-D02.02ARS(SOCSOUTH ARS Bldg736).pdf PDF
FSS-PWS-H-TE-H07.01(ExteriorLighting-DoralSite).pdf PDF
FSS-PWS-H-TE-H08.01(StormWater-Doral).pdf PDF
FSS-PWS-D-TE-D02.02(Hmstd-Bldg736).pdf PDF
FSS-PWS-H-TE-H05(BUILDER-References).pdf PDF
FSS-PWS-F-TE-F01.01 (GrdsMap-Doral).pdf PDF
FSS-PWS-K-TE-K01.02(FacilityList-Hmstd).pdf PDF
FSS-PWS-D-TE-D02.01ARS(SOCSOUTH ARS Bldg600).pdf PDF
FSS-PWS-F-TE-F02.01 (GrdsMap-Hmstd).pdf PDF
FSS-PWS-H-TE-H03(PMChecklist).pdf PDF
FSS-PWS-F-TE-F01.03 (GrdsSpecs-Doral).pdf PDF
FSS-PWS-D-TE-D01.06(Doral-LRC).pdf PDF
FSS-PWS-A-TE-A04.01 (DD254-Doral).pdf PDF
FSS-PWS-E-TE-E02 (SolidWaste-Hmstd).pdf PDF
Show 40 more

Latest 50 of 78 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

USAG-Miami FSS, Annex D (Custodial Services) Technical Exhibit D02.03ARS – SOCSOUTH ARS, Homestead Bldg 741

D02.03ARS. Homestead Bldg 741. This facility has approximately 17,180 SF of space receiving services (excludes utility and storage spaces that do not receive scheduled custodial services, and reduced by 15% for furnishings), See Technical Exhibit D02.03.

D02.03ARS-1. Homestead Bldg 741, SOCSOUTH ARS. This zone includes 17,180 SF receiving services (excluding utility and storage spaces that do not receive scheduled custodial services, and reduced by 15% for furnishings). See Technical Exhibit D02.03.

Homestead, Bldg 741 SOCSOUTH – ARS (1)

Custodial Task Standard / Description (Ref Para) ABS Level

See D-3.1 and 3.1.1

ARS

Level

Restrooms/Baths/Locker Rooms (D-2.9,9.1-9.5) 3W (2) Stairways/Entries/Lobbies/Corridors/Elevators(D-2.7) N/A Drinking Fountains (D-2.10) 3W (2) Remove Waste - Open/Private Offices (D-2.8) N/A (3) Remove Waste - Common Areas (D-2.8) 3W (3) Recyclable Removal – Common Areas (D-2.8) 3W (3) Carpet – Vacuum/Spot Clean (D-2.5,2.5.1,2.5.3) 1W Carpet – Deep Cleaning/Shampoo (D-2.5.2) EOY Hard Floor – Sweep/Spot Clean (D-2.4,2.5.3) 2M (4) Hard Floor – Wet Mop (D-2.4,2.4.3) 1M (4) Hard Floor – Dry/Spray Buff (D-2.4,2.4.1) EOY Hard Floor – Strip/Finish (D-2.4,2.4.2) EOY Dusting – Low (D-2.11,2.11.1) 1Y Dusting – High (D-2.11,2.11.2) 1Y Windows/Glass – Interior (D-2.12,2.13,2.13.1) EOY

Windows/Glass – Exterior (D-2.13) EOY Window Treatments – Dust (D-2.11,2.11.1,2.11.2) EOY Kitchens/Break Rooms (D-2.16.1) 3W (2)

SPECIAL NOTES:

(1) Security Clearance Requirements: Contractor employees supervising or employing custodial services in this facility or zone must obtain and maintain a DoD SECRET security clearance.

(2) Clean Elevators/Entries/Lobbies in not required (there are no Elevators/Entries/Lobbies);

Clean/Disinfect/Supply Kitchens/Break Rooms, Clean/Disinfect/Supply Restrooms/Baths, and Clean/Disinfect Drinking Fountains will be performed 3 times per week (3W).

(3) Trash and Recyclables will ONLY be removed from consolidated Common Area collection receptacles in Break Rooms, Stairwells and other Common areas 3 times per week time per day (1D), and will NOT be removed from Open and Private Office/Work areas.

(4) Hard Floor – Sweep/Spot lean will be performed two times per month (2M) and Wet Mop shall be performed 1 time per month (1M).

File details come from the government source that posted it. Updated .