Florida_Trench_Safety_Form.pdf

PDF 96 KB Posted

Attached to
Fiscal Year 2027 Pavement Preservation - Package 2
Solicitation number
26-0362-ITB-C
Issued by
Pinellas County, Clewiston City, Florida

About this file

This is a Florida Trench Safety Certification and Disclosure Statement form required for bidders on Pinellas County's Fiscal Year 2027 Pavement Preservation Package 2 project. The document establishes that bidders must comply with the Florida Trench Safety Act (Section 553.60 et seq., Florida Statutes) and the Federal excavation safety standards outlined in 29 C.F.R. Section 1926.650 Subpart P. Bidders are required to acknowledge these requirements and identify all excavation and trench safety measures they will employ on the project, which involves pavement preservation and milling/resurfacing work across approximately 33.27 lane miles of roadway in Pinellas County, consisting of one arterial and three local group projects.

Bidders must complete the disclosure table detailing specific trench safety measures, units of measure (linear feet or square feet), quantities, unit costs, and extended costs for each safety measure employed. The form explicitly states that disclosed safety costs are for compliance documentation purposes only and do not represent payment line items. Contractors bear sole responsibility for selecting appropriate geotechnical data and designing adequate trench safety systems, and any additional costs necessary to achieve compliance with applicable safety standards must be absorbed by the contractor at no additional expense to the County. The County's acceptance of a bid does not constitute evaluation or approval of the disclosed safety costs nor does it relieve the contractor of full compliance obligations. Failure to complete this form may result in the bid being declared non-responsive.

View the file

Other files

File Type Posted
ADD1_Step_1_26-0362_signed.pdf PDF
ADD1_Step_1_26-0362_signed.pdf PDF
Appendix_6_-_Local_Group_221_Street_Maps.pdf PDF
Appendix_6_-_Local_Group_221_Street_Maps.pdf PDF
ADD1_Step_1_26-0362_signed.pdf PDF
Appendix_6_-_Local_Group_221_Street_Maps.pdf PDF
Fiscal_Year_2027_Pavement_Preservation_-_Package_2.pdf PDF
Pricing_Proposal_26-0362(reference_only).pdf PDF
Common_Carrier_Attestation_02.05.2025.pdf PDF
Human_Trafficking_Affidavit_02.05.2025_(3).pdf PDF
SBE_Compliance_Form.pdf PDF
Sample_Agreement-26-0362.pdf PDF
Foreign_Countries_of_Concern_Affidavit_02.05.2025_(1).pdf PDF
4.26.Performance_and_Payment_Bonds.pdf PDF
Affdavit_of_Release_and_Guarantee.pdf PDF
Sample_Change_Order.pdf PDF
Sample_Application_for_Payment.pdf PDF
LG_221_-_Airport_(PID_006826A)_.pdf PDF
Plans_-_Lansbrook_B_(PID_006772A).pdf PDF
McMullen_Booth_-Plans_.pdf PDF
Plans_-_LG_212_(PID_006825A).pdf PDF
Specifications.pdf PDF
Appendix_4-Special_Notices_.pdf PDF
APPENDIX_-_1_-_Permits_.pdf PDF
E-Verify_Affidavit.pdf PDF
Airport_Security_Program.pdf PDF
Non-Competitive_Oversight_Committee_Justification_Form.docx DOCX document
Engineer_Estimate_(For_Review_Only).xlsx XLSX spreadsheet
Notice_of_Intent_to_Sole_Source_07-25-2023.pdf PDF
Bid_Submittal_Form-JOC.pdf PDF
LOCATION_MAP.PDF PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FLORIDA TRENCH SAFETY

FLORIDA TRENCH SAFETY ACT

CERTIFICATION AND DISCLOSURE STATEMENT

The undersigned acknowledges the requirements of the Florida Trench Safety Act (Section 553.60 et. seq. Florida Statutes).

A. The Bidder further acknowledges that the Florida Trench Safety Act, (the Act) establishes the Federal excavation safety standards set forth at 29 C.F.R. Section 1926.650 Subpart P, as the interim state standard until such time as the state of Florida, through its Department of Labor and Employment Security, or any successor agency, adopts, updates, or revises said interim standard. This State of Florida standard may be supplemented by special shoring requirements established by the State of Florida or any of its political subdivisions.

B. The Bidder, as Contractor, shall comply with all applicable excavation/trench safety standards.

C. The contractor shall consider the geotechnical data available from the County, if any, the Contractor's own sources, and all other relevant information in its design of the trench safety system to be employed on the subject Project. The Contractor acknowledges sole responsibilities for the selection of the data on which it relies in designing the safety system, as well as for the system itself.

D. The amounts that the Bidder has set forth for pipe installation includes the following excavation/trench safety measures and the linear feet of trench excavated under each safety measure. These units, costs, and unit values shall be disclosed solely for the purpose of compliance with procedural requirements of the Act. No adjustment to the Agreement Time or price shall be made for any difference in the actual number of linear feet of trench excavation, except as may be otherwise provided in these Contract Documents.

Trench Safety Measure (Description)

Units of Measure

(LF, SF)

Unit (Quantity)

Unit Cost

Extended Cost

1. $ $

2. $ $

3. $ $

4. $ $

5. $ $ For Information Only, Not for Payment Purposes $

FLORIDA TRENCH SAFETY

Bidder may use additional sheets as necessary to extend this form. Failure to complete the above may result in the bid being declared non-responsive.

A. The amount disclosed as the cost of compliance with the applicable trench safety requirements does not constitute the extent of the Contractor’s obligation to comply with said standards. The Contractor shall extend additional sums at no additional cost to the County, if necessary, to comply with the Act (except as otherwise be provided).

B. Acceptance of the bid to which this certification and disclosure applies in no way represents that the County or its representatives has evaluated and thereby determined that the above costs are adequate to comply with the applicable trench safety requirements nor does it in any way relieve the Contractor of its sole responsibility to comply with the applicable trench safety requirements.

Company Name

Name and Title

Address: Telephone/Fax

Federal Employee ID NO. (FEIN)

Email of Account Representative