Fire Protection and Suppression.docx
DOCX document 37 KB Posted
- Attached to
- Pre-Commerical Tree Thinning
- Solicitation number
- S-X06001-00011900
- Issued by
- Lane County, Oregon
About this file
This document outlines the fire protection and suppression requirements for a contract or agreement involving the Confederated Tribes of Coos, Lower Umpqua and Siuslaw Indians (CTCLUSI) Tribal Forest. The document covers the fire period and closed season, fire plan requirements, substitute measures, emergency measures, fire control responsibilities, compliance with state forest laws, and specific fire precautionary measures such as smoking restrictions, fire extinguisher and equipment requirements, spark arresters, and an industrial fire precautions schedule. The document also details requirements for fire tools, fire security personnel, and additional precautionary measures including the provision of a tank truck or trailer and communications equipment. The fire protection and suppression requirements apply to all use of the Tribal Forest, including motorized and non-motorized access, commercial and non-commercial harvest, and recreational activities.
The fire protection and suppression requirements are likely included as part of a larger contract or agreement related to the management or use of the CTCLUSI Tribal Forest. The document specifies the roles and responsibilities of the contractor and the Tribe in preventing and suppressing fires within the project area.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Definitions.docx | DOCX document | |
| Invitation To Bid.docx | DOCX document | |
| ROAD USE RULES AND RESTRICTIONS.docx | DOCX document | |
| Sample Contract.docx | DOCX document | |
| 4 of 5.pdf | ||
| Exhibit A~1.pdf | ||
| Contract 259999B001 Final DOJ approved for posting~1.pdf | ||
| Exhibit A.docx | DOCX document | |
| Exhibit B Project Maps.docx | DOCX document | |
| Statement of Qualifications and Capacity.docx | DOCX document | |
| overview 10_29_24.pdf | ||
| Optional Pre-Bid Site Meeting~1.pdf | ||
| ADDENDUM 2 CTCLUSI.pdf | ||
| Definitions.pdf | ||
| 1 of 5.pdf | ||
| 3 of 5.pdf | ||
| 5 of 5.pdf | ||
| Exhibit C Bid Forms.docx | DOCX document | |
| Signature of the Bidder.docx | DOCX document | |
| 2 of 5.pdf | ||
| FIRE SUPPRESSION AND ROAD USE RULES AND RESTRICTIONS.pdf |
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRE PROTECTION AND SUPPRESSION
1. Fire Period and Closed Season Subject to the exceptions listed below, areas within the CTCLUSI Tribal Forest are closed when the Industrial Fire Precaution Level (IFPL) is at Level II or higher for that area. This closure pertains to all use including motorized and non-motorized access, commercial and non-commercial harvest of forest products, hunting, shooting, camping, and all forms of recreation.
Current IFPL levels can be determined by calling the appropriate number as listed below, or by visiting http://gisapps.odf.oregon.gov/firerestrictions/ifpl.html in your web browser.
| Tribal Forest Area |
| Fire Protection Responsibility |
| Fire Protection Zone |
| Contact for Latest IFPL Level |
| Lake Tract |
| ODF — Western Lane District |
| WT-1 |
| (541) 935-2222 |
| Smith Tract |
| ODF — Western Lane District |
| WT-1 |
| (541) 935-2222 |
| Tioga Tract |
| Coos Fire Protection Association |
| CS-2 |
| (541) 267-1789 |
| Macy Tract |
| Coos Fire Protection Association |
| CS-1 |
| (541) 267-1789 |
| Umpqua Eden |
| Coos Fire Protection Association |
| CS-1 |
| (541) 267-1789 |
| Coos Head |
| Coos Fire Protection Association |
| CS-1 |
| (541) 267-1789 |
| Talbot Tract |
| Coos Fire Protection Association |
| CS-1 |
| (541) 267-1789 |
Exceptions:
The following exceptions are made to this closure order:
1) Motorized and non-motorized travel is permitted across the roads listed below for the limited purpose of accessing private and public lands that remain open to public use.
- Lake Creek Road (Lake Tract)
- Prairie Mountain Road (Lake Tract)
- Mill Pond Road (Lake Tract)
- East Fork Spencer Creek Road (Smith Tract)
- Coon Creek Ridge Road (Smith Tract)
- Johnson Creek Ridge Road (Smith Tract)
- Burnt Creek Ridge Road (Tioga Tract)
- Bastendorf Beach Road (Coos Head)
- Coos Head Road (Coos Head)
- Coos Head Loop (Coos Head)
- Chicken Loop Road (Coos Head) Adjacent forestlands owners may continue to cross Tribal roads when doing so is necessary for forest management purposes. This access is subject to any additional closures or restrictions issued by the Coos Fire Protection Association or ODF — Western Lane District.
Adjacent landowners may continue to utilize easements across Tribal lands when doing so is necessary for access to residential dwellings. This exception applies to Coos Head only.
The Forest Lands Manager may issue waivers to this closure order. Such waivers shall only be valid if they are in writing, dated, and carried by the person(s) having been granted the waiver. Waivers shall expire one year from the date on which they are issued, unless a shorter term is specified in the waiver. Waivers are revocable at any time.
2. Fire Plan Before starting any operations on the project, the Contractor shall prepare a fire plan in cooperation with the Owner Representative providing for the prevention and control of fires in the project area. The Contractor shall certify compliance with fire protection and suppression requirements before beginning operations during the fire period and closed season, and shall update such certification when operations change.
3. Substitute Measures The Owner Representative may by written notice authorize substitute measures or equipment or may waive specific requirements during periods of low fire danger.
4. Emergency Measures The Tribe may require emergency measures, including the necessary shutting down of equipment or portions of operations in the project area during periods of fire emergency created by hazardous climatic conditions.
5. Fire Control The Contractor shall, independently and in cooperation with the Tribe, take all reasonable action to prevent and suppress fires in the project area. Independent initial action shall be prompt and shall include the use of all personnel and equipment available in the project area.
6. Compliance with State Forest Laws Listing of specific fire precautionary measures herein is not intended to relieve the Contractor in any way from compliance with the State Fire Laws covering fire prevention and suppression equipment, applicable to operations under this contract, permit or license.
7. Fire Precautions Specific fire precautionary measures are as follows:
a. Smoking and Open Fires Smoking and fires shall be permitted only at the option of the Contractor. The Contractor shall not allow open fires on the project area without advance permission in writing from the Tribe.
Unless restricted by State Law or Federal Regulation, smoking shall be permitted only in such portions of the project area that are free of flammable material. Smokers shall sit down to smoke in such a position that any burning material will fall within a cleared area, and shall extinguish and press out in mineral soil all burning material before leaving the cleared area.
b. Fire Extinguishers and Equipment on Trucks, Tractors, etc.
All power-driven equipment operated by the Contractor on Tribal land, except portable fire pumps, shall be equipped with one fire extinguisher having a UL rating of at least 5 BC, and one "D" handled or long handled round point shovel, size "0" or larger. In addition, each motor patrol, truck and passenger-carrying vehicle shall be equipped with a double-bit axe or Pulaski, 3-1/2 pounds or larger. Equipment shall be kept in a serviceable condition and shall be readily available.
c. Power Saws Each gasoline power saw operator shall be equipped with a pressurized chemical fire extinguisher of not less than 8-ounce capacity by weight, and one long-handled round point shovel, size "0" or larger. The extinguisher shall be kept in possession of the saw operator at all times. The shovel shall be accessible to the operator within 1 minute.
d. Extinguishers One refill for each type or one extra extinguisher sufficient to replace each size extinguisher required on equipment shall be safely stored in the fire tool box or other agreed upon place on the project area that is protected and readily available.
e. Spark Arresters and Mufflers Each internal combustion engine shall be equipped with a spark arrester meeting either (1) USDA Forest Service Standard 5100-1a, or (2) appropriate Society of Automotive Engineers (SAE) recommended practice J335(b) and J350(a) as now or hereafter amended unless it is:
(1) Equipped with a turbine-driven exhaust supercharger such as the turbocharger. There shall be no exhaust bypass.
(2) A passenger-carrying vehicle or light truck, or medium truck up to 40,000 GVW, used on roads and equipped with a factory-designed muffler complete with baffles and an exhaust system in good working condition.
(3) A heavy duty truck, such as a dump or log truck, or other vehicle used for commercial hauling, used only on roads and equipped with a factory designed muffler and with a vertical stack exhaust system extending above the cab.
Exhaust equipment described in this subsection, including spark arresters and mufflers, shall be properly installed and constantly maintained in serviceable condition.
f. Emergency Fire Precautions The Contractor shall restrict operations in accordance with the Industrial Fire Precaution Levels listed below.
INDUSTRIAL FIRE PRECAUTIONS SCHEDULE
LEVEL INDUSTRIAL FIRE PRECAUTION (IFPL)
I. Closed season - Fire precaution requirements are in effect. A fire watch/security is required at this and all higher levels unless otherwise waived.
II. Partial hootowl - The following may operate only between the hours of 8 p.m. and 1 p.m., local time:
a. Power saws, except at loading sites;
b. Cable yarding;
c. Blasting;
d. Welding or cutting of metal.
III. Partial shutdown - The following shall be prohibited except as indicated:
Cable yarding - except that gravity operated logging systems employing non-motorized carriages may be operated between the hours of 8 p.m. and 1 p.m., local time, when all block and moving lines, except the line between the carriage and the chokers, are suspended 10 feet above the ground;
Power saws - except power saws may be used at loading sites and on tractor/skidder operations between the hours of 8 p.m. and 1 p.m., local time.
In addition, the following are permitted between the hours of 8 p.m. and 1 p.m., local time:
a. Tractor/skidder operations;
b. Mechanized loading and hauling of any product or material; c. Blasting;
d. Welding or cutting of metal;
e. Any other spark-emitting operation not specifically mentioned.
IV. General shutdown - All operations are prohibited.
The following definitions shall apply to these Industrial Fire Precaution Levels:
Cable yarding systems: A yarding system employing cables and winches in a fixed position.
Closed season (Fire Precautionary Period): That season of the year when a fire hazard exists as declared by the responsible agency official.
Owner Representative: The person executing the contract, permit or license on behalf of the Government and includes that person's designated representative, acting within the limits of their authority or the duly appointed successor to the individuals.
Loading sites/woods site/project area: A place where any product or material (including but not limited to logs, firewood, slash, soil, rock, poles, posts, etc.) is placed in or upon a truck or other vehicle.
Low hazard area: Means any area where the responsible agency representative (WDNR, ORF, BIA, BLM) determines the combination of elements reduces the probability of fire starting and/or spreading.
Tractor/skidder operations: include a harvesting operation, or portion of a harvesting operation, where tractors, skidders, or other harvesting equipment capable of constructing fire line, are actively yarding forest products and can quickly reach and effectively attack a fire start.
Waivers, written in advance, may be used for any and all activities. Activities for which waivers may be issued include, but are not limited to:
a. Mechanized loading and hauling;
b. Road maintenance such as sprinkling, graveling, grading and paving;
c. Cable yarding using gravity systems or suspended lines and blocks, or other yarding systems where extra prevention measures will significantly reduce the risk of fire;
d. Powers saws at loading sites or in felling and bucking where extra prevention measures will significantly reduce the risk of fire;
e. Maintenance of equipment (other than metal cutting and welding) or improvements such as structures, fences and power lines.
Such waiver, or substitute precautions will prescribe measures to be taken by the Contractor to reduce the risk of ignition, and/or the spread of fire. The Owner Representative shall consider site-specific weather factors, fuel conditions, and specific operations that result in less risk of fire ignition and/or spread than contemplated when precaution level was predicted. Consideration shall also be given to measures that reduce the precaution levels above. The Contractor shall assure that all conditions of such waivers or substitute precautions are met.
The Contractor shall obtain the predicted Industrial Fire Precaution Level daily, prior to the start of work, from the appropriate Ranger District headquarters. If predictions made after 6:00 p.m., local time, are significantly different than the original prediction, the Forest Service will inform the Contractor when changes in restrictions or industrial precautions are made.
NOTE: The IFPL system does not apply on lands protected by ODF east of the summit of the Cascades.
Where hauling involves transit through more than one shutdown/regulated use area, the precaution level at the woods loading site shall govern the level of haul restriction, unless otherwise prohibited by other than industrial precaution level system.
8. Fire Tools
The Contractor shall furnish serviceable firefighting tools in a readily accessible fire tool box or compartment of sound construction with a hinged lid and hasp so arranged that the box can be secured or sealed. The box shall be red and marked "Fire Tools" in letters one inch high. It shall contain a minimum of:
a. 2 axes or Pulaskis with a 32-inch handle;
b. 3 adze eye hoes. One Pulaski may be substituted for 1 adze eye hoe;
c. 3 long-handled, round point shovels, size "0" or larger.
9. Fire Security
When the Industrial Fire Precautions Level is “I” or higher, unless a waiver is granted, the Contractor shall designate a person who shall perform fire security services listed below on the project area and vicinity. The designated person shall be capable of operating the Contractor's communications and firefighting equipment specified in the contract, excluding helicopters, and of directing the activities of the Contractor's personnel on forest fires. In lieu of having the designated person perform the required supervisory duties, the Contractor may provide another person meeting the qualifications stated above to direct the activities of Contractor's personnel and equipment during all firefighting activities.
Services described shall be for at least 1 hour from the time the Contractor's operations are shut down. For the purposes of this provision, personnel servicing equipment, and their vehicles, who are not engaged in cutting or welding metal are excluded.
Fire security services shall consist of moving throughout the operation area or areas constantly looking, reporting, and taking suppression action on any fires detected. Where possible, the designated person shall observe inaccessible portions of helicopter operating areas from vantage points within or adjacent to project area.
10. Blasting
Whenever the Industrial Fire Precaution Level is “II” or greater, a fire security person equipped with a long-handled, round point, No. “0” or larger, shovel, and a five-gallon backpack pump can filled with water will stay at location of blast for 1 hour after blasting is done. Blasting may be suspended by Forest Service in writing, in an area of high rate of spread and resistance to control.
Fuses shall not be used for blasting. Explosive cords shall not be used without written permission of Forest Service, which may specify conditions under which such explosives may be used and precautions to be taken.
Additional Fire Precautionary Measure 1 - Tank Truck
11. The Contractor shall provide a tank truck or trailer, containing not less than 300 gallons of water. A tank truck or trailer will not be required if handwork (including power saw operation) is the only work being performed. Such tank truck or trailer shall be maintained in a serviceable condition and located within 10 minutes, round trip, from each project area during fire period and closed season.
The tank truck or trailer shall be equipped with a pump capable of discharging 20 gallons of water per minute, using a ¼ inch nozzle tip, through a 50 foot length of rubber lined hose. In addition, 500 feet of serviceable fabric jacket rubber lined hose of not less than 1 inch outside diameter, fitted with a nozzle capable of discharging a straight stream of ¼ inch diameter and a spray pattern, shall be immediately available for use. The tank, pump and at least 250 feet of hose and nozzle shall be connected and ready for use at all times.
If a trailer is used, it shall be equipped with a hitch to facilitate prompt movement. A serviceable tow vehicle shall be immediately available for attachment to the trailer and must meet the time requirements stated above. Such truck or trailer shall be equipped to operate for a minimum of 8 hours. Tank truck or trailer shall be available from the start of work to the end of the Fire Watch/Fire Security service
Additional Fire Precautionary Measure 2 - Communications
12. The Contractor shall provide adequate two-way communication facilities to report a fire to the Forest Service within 15 minutes of detection. FCC Regulations prohibit commercial use of Citizen Band [CB] radios. (CBs are not considered adequate two-way communications).
Such communications shall be operable during periods of operation of power driven equipment and shall also include the time fire security is required.