FINAL_PLANS-11-8-2022_Re-Bid.pdf
PDF 9 MB Posted
- Attached to
- Countywide Mast Arms - Group 3 (Rebid)
- Solicitation number
- 24-0633-ITB-C
- Issued by
- Pinellas County, Clewiston City, Florida
About this file
These are final engineering plans for the Pinellas County Public Works Department's Countywide Mast Arm Signal Hardening and Intersection Improvement project, specifically covering three intersections: E. Tarpon Ave at US 19, Lake St. George Dr at Tampa Rd, and West Lake Rd at Tampa Rd. The project involves comprehensive traffic signal infrastructure upgrades, including installing new mast arm signal assemblies, updating signalization, performing minor roadway improvements, and ensuring Americans with Disabilities Act (ADA) compliance. The plans, dated November 8, 2022, detail precise engineering specifications for signal pole placement, foundation design, electrical infrastructure, fiber optic communications, and associated roadway modifications.
The project documents indicate a complex multi-phase infrastructure improvement effort requiring specialized traffic engineering and construction expertise. The plans include detailed soil boring reports revealing predominantly sandy soil conditions with varying density, which will impact foundation design. Technical specifications mandate strict compliance with Florida Department of Transportation (FDOT) standards, Pinellas County technical specifications, and include comprehensive requirements for utility coordination, traffic maintenance during construction, erosion control, and post-construction site restoration. The project will involve coordinating with multiple utility providers, including Clearwater Gas System, Duke Energy, Frontier Communications, and Pinellas County Utilities, to ensure minimal disruption to existing infrastructure.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FINAL PLANS
11/08/2022
PID 004183A
COUNTYWIDE MAST ARM SIGNAL HARDENING AND
INTERSECTION IMPROVEMENT
entzt44 Line entzt44 Line
PID 004183E
COUNTYWIDE MAST ARM SIGNAL HARDENING AND
INTERSECTION IMPROVEMENT
LAKE ST GEORGE DR AT TAMPA RD
SHEET NO.
TE-1
TE-2
TE-3
TE-4 - TE-5
TE-6
TE-8
TE-9
TE-10 - TE-11
TE-12
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
SHEET DESCRIPTION
KEY SHEET
SIGNATURE SHEET
TABULATION OF QUANTITIES
GENERAL NOTES
SIGNALIZATION PLAN
GUIDESIGN WORKSHEET
SPLICING DIAGRAM
BEST MANAGEMENT PRACTICES PLANS & NOTES
MAST ARM TABULATION
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
HNTB CORPORATION
ONE TAMPA CITY CENTER
201 N FRANKLIN ST. SUITE 1200
TAMPA, FL 33602
BENJAMIN S. RODGERS, P.E. NO. 80350
TE-13
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
SHEET DESCRIPTION
REPORT OF CORE BORING
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
MC SQUARED, INC.
GEOTECHNICAL CONSULTANTS
5808-A BRECKENRIDGE PARKWAY
TAMPA, FL 33610
JORDAN FOX, P.E. NO. 87472
TE-14 - TE-19
THE ABOVE NAMED PROFESSIONAL SURVEYOR AND MAPPER SHALL BE RESPONSIBLE
FOR THE FOLLOWING SHEETS IN ACCORDANCE WITH RULE 5J-17.062, F.A.C.
SHEET DESCRIPTION
LAND SURVEYOR REPORT
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
ECHEZABAL & ASSOCIATES, INC. LB6490
108 W. COUNTRY CLUB DR.
TAMPA, FL 33612
STEPHEN M. TATE, P.S.M. 5242
P R O
FESSIONAL EN
GIN
EE
R
L I C E N S E
F L O R I D A
BE
NJ
AM
IN S. RODGERS
P R O
FESSIONAL EN
GIN
EE
R
L I C E N S E
F L O R I D A
JOR
DAN FOX
P R O
FESSIONAL SURV
EY
O R
L I C E N S E
F L O R I D A
ST
EPH
EN M. TATE
STATE OF
P R O
FESSIONAL ENGIN
EE
R
L I C E N S E
F L O R I D A
JU
LIA
N GUTIERREZ
No 48879
SHEET NO.
TE-7
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
SHEET DESCRIPTION
STANDARD MAST ARM ASSEMBLIES DATA TABLE
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
HNTB CORPORATION
ONE TAMPA CITY CENTER
201 N FRANKLIN ST. SUITE 1200
JULIAN GUTIERREZ, P.E. NO. 48879
TABULATION OF QUANTITIES
PAY
ITEM NO.
REF.
SHEET
FINALPLANFINAL PLANFINALPLAN FINALPLAN
DESCRIPTION
SHEET NUMBERS
UNIT
FINALPLANFINAL PLANFINALPLANFINALPLAN PLANFINAL
GRAND
TOTAL
TOTAL
THIS
SHEETTE-6
IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CONFIRM THE NECESSARY LENGTH OF THE PRE-TERMINATED FIBER
OPTIC DROP CABLE AT EACH LOCATION PRIOR TO ORDERING.
635-2-70:
THIS PAY ITEM SHALL INCLUDE THE COST ADJUST/RELOCATE EXISTING CONDUIT AND CLEAN AND RE-ROCK EXISTING
PULL/SPLICE BOX.
660-4-11, 660-4-12:
THE VIDEO DETECTION CAMERA SYSTEM SHALL BE ECONOLITE AUTOSCOPE VISION. INCLUDE AN AUTOSCOPE COMM MANAGER AS PART OF THE SYSTEM. COORDINATE WITH THE COUNTY TO ENSURE SOFTWARE AND FIRMWARE
COMPATIBILITY.
660-4-60:
INCLUDES REMOVAL OF ALL VIDEO DETECTION CAMERAS, BRACKETS, MOUNTING HARDWARE, AND CABLING. CABLING SHALL BE REMOVED IN FULL LENGTHS UNCUT. DELIVER ALL CAMERAS AND HARDWARE REMOVED TO PINELLAS COUNTY
PUBLIC WORKS.
663-111, 663-112:
THE OPTICAL PREEMPTION SYSTEM SHALL CONSIST OF OPTICOM MODEL 711 OVERHEAD DETECTORS AND A MODEL 764
PHASE SELECTOR.
670-5-112:
PROVIDE A CONTROLLER ASSEMBLY FULLY FIBER READY AND COMPATIBLE WITH ALL PINELLAS COUNTY REQUIREMENTS FOR INTEGRATION INTO THE COUNTY SYSTEM. THE CONTROLLER SHALL BE AN ECONOLITE COBALT.
682-1-113:
INCLUDE THE COST OF SURGE PROTECTION DEVICES (SPD) ON BOTH ENDS OF THE CAMERA POWER-OVER-ETHERNET (POE) CABLE AND THE JUNCGION BOXES NEEDED FOR HOUSTING THE SPD. FOR THE NEAR SIDE (CABINET SIDE) SPD PLACE THE SPD INSIDE THE TRAFFIC CONTROLLER CABINET. FOR THE FAR SIDE SPD PLACE THE SPD IN A WATER-PROOF JUNCTION BOX NEAR THE CAMERA MOUNTING BRACKET AND ON TOP OF THE TRAFFIC SIGNAL MAST ARM.
685-1-13:
THE UPS SHALL BE A MYERS 2000E INSTALLED IN A SEPARATE CABINET ON THE CONTROLLER BASE AS PER COUNTY
STANDARDS.
GOVERNING SPECIFICATIONS AND STANDARDS:
1. FLORIDA DEPARTMENT OF TRANSPORTATION DIVISION II AND III OF "STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION", (JANUARY 2022) AND ALL SUPPLEMENTAL SPECIFICATIONS THERETO. STANDARD SPECIFICATIONS ARE AVAILABLE AT THE FOLLOWING WEBSITE: HTTP://WWW.FDOT.GOV/PROGRAMMANAGEMENT/IMPLEMENTED/SPECBOOKS
2. FLORIDA DEPARTMENT OF TRANSPORTATION FY (2022-2023) STANDARD PLANS FOR ROAD AND BRIDGE CONSTRUCTION AND APPLICABLE INTERIM REVISIONS (IRs). STANDARD PLANS FOR ROAD CONSTRUCTION AND IRs ARE AVAILABLE AT THE FOLLOWING WEBSITE: HTTP://WWW.FDOT.GOV/DESIGN/STANDARDPLANS. COMPLIANCE WITH ALL APPLICABLE INDICES IS
REQUIRED.
3. STATE OF FLORIDA "MANUAL OF UNIFORM MINIMUM STANDARDS FOR DESIGN, CONSTRUCTION AND MAINTENANCE FOR STREETS AND HIGHWAYS", 2018 (FLORIDA GREENBOOK) HTTP://WWW.FDOT.GOV/ROADWAY/FLORIDAGREENBOOK/FGB.SHTM
4. PINELLAS COUNTY "STANDARD TECHNICAL SPECIFICATIONS FOR UTILITIES & RELATED CONSTRUCTION" JANUARY 2022
AVAILABLE ON-LINE:HTTP://WWW.PINELLASCOUNTY.ORG/TECHNICAL/
5. PINELLAS COUNTY "STANDARD ENGINEERING DETAILS" JUNE 2022 AVAILABLE ON-LINE:
HTTP://WWW.PINELLASCOUNTY.ORG/TECHNICAL/
6. PINELLAS COUNTY "TRAFFIC OPERATIONS SIGNAL STANDARDS" 2017.1 EDITION AVAILABLE BY REQUEST WHEN FDOT AND PINELLAS COUNTY SPECIFICATIONS DIFFER, PINELLAS COUNTY SPECIFICATIONS SHALL TAKE PRECEDENCE IF PINELLAS
COUNTY'S IS MORE STRINGENT AS DETERMINED BY THE ENGINEER.
7. PINELLAS COUNTY SUPPLEMENTAL SPECIFICATIONS FOR ROADWAY AND GENERAL CONSTRUCTION, APRIL 2022
8. WHEN FDOT AND PINELLAS COUNTY SPECIFICATIONS DIFFER, PINELLAS COUNTY SPECIFICATIONS SHALL TAKE
PRECEDENCE IF PINELLAS COUNTY'S IS MORE STRINGENT AS DETERMINED BY THE ENGINEER.
NOTIFICATIONS:
1. CONTACT PINELLAS COUNTY TRAFFIC ENGINEERING, (727-464-8922) PRIOR TO THE BEGINNING OF WORK TO CHECK
FOR UPDATES TO STANDARDS OR OTHER INFORMATION.
2. ONE WEEK PRIOR TO THE BEGINNING OF WORK, NOTIFY:
MR. JOHN LEMONIAS, PINELLAS COUNTY
22211 US 19 NORTH CLEARWATER, FL 33765
PHONE: (727) 420-6270
MR. VINCE HARPER, PINELLAS COUNTY
22211 US HIGHWAY 19 NORTH
CLEARWATER, FL 33765
PHONE: (727) 410-6301
MR. WAYNE DEMPSEY
FDOT DISTRICT SEVEN TRAFFIC OPERATIONS
CONSTRUCTION LIAISON
FLORIDA DEPARTMENT OF TRANSPORTATION
11201 NORTH McKINLEY DRIVE
TAMPA, FLORIDA 33612
PHONE (813) 975-6226
3. GIVE THE ENGINEER A MINIMUM OF TWO FULL BUSINESS DAYS NOTICE PRIOR TO FOUNDATION EXCAVATION FOR
MAST ARMS FOR FINAL LOCATION APPROVAL.
4. OBTAIN LOCAL PERMITS TO WORK OUTSIDE THE FDOT AND COUNTY RIGHT OF WAY ON LOCAL STREETS.
WORK SUPERVISION:
1. AN I.M.S.A. CERTIFIED LEVEL II (ELECTRONICS OR ELECTRICAL) TECHNICIAN ON THE JOB SITE AT ALL TIMES WHEN
WORKING WITHIN THE TRAFFIC SIGNAL CONTROLLER CABINET, SIGNAL POLES OR MAST ARM ASSEMBLIES.
2. RESPOND TO CALLS TWENTY-FOUR HOURS A DAY, SEVEN DAYS A WEEK. WITHIN THREE HOURS OF NOTIFICATION OR
DOCUMENTED ATTEMPTED NOTIFICATION, THE CONTRACTOR SHALL BE ON-SITE MAKING NEEDED REPAIRS OR MODIFICATIONS. FAILURE TO MEET THE TIME REQUIREMENTS GIVES THE COUNTY, AT THEIR DISCRETION, THE RIGHT TO REQUEST ASSISTANCE FROM LOCAL LAW ENFORCEMENT TO CONTROL TRAFFIC FOR THE PERIOD OF TIME UNTIL THE CONTRACTOR RESPONDS AND MAKES NEEDED REPAIRS. THE COST FOR LAW ENFORCEMENT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE COUNTY, AT THEIR DISCRETION, ALSO HAS THE RIGHT TO BRING IN ASSISTANCE TO MAKE NEEDED REPAIRS AND BE REIMBURSED BY THE CONTRACTOR, IF THE CONTRACTOR CANNOT
MEET THE TIME REQUIREMENTS.
3. A SUPERINTENDENT FOR THE PRIME CONTRACTOR IS REQUIRED TO BE ON SITE AT ALL TIMES WHEN WORK IS BEING PERFORMED. ALL WORKERS ON THE JOB SITE WILL BE COURTEOUS TO THE PUBLIC AT ALL TIMES AND SHALL REFER ANY QUESTIONS OR CONCERNS TO THE CONTRACTOR'S SUPERINTENDENT OR THE COUNTY INSPECTOR. THE SUPERINTENDENT SHALL SPEAK AND UNDERSTAND ENGLISH AND SHALL BE AVAILABLE AT ALL TIMES FOR TIMELY RESOLUTION OF PROJECT RELATED ISSUES. PROVIDE A 24 HOUR EMERGENCY PHONE NUMBER TO THE COUNTY INSPECTOR.
TRAFFIC CONTROL/EQUIPMENT:
1. DURING CONSTRUCTION ALL EXISTING SIGNALIZATION SHALL REMAIN IN PLACE, INCLUDING VEHICLE ACTUATION AND
PEDESTRIAN SIGNAL OPERATION. ALL ACTUATED PHASES SHALL BE MAINTAINED DURING THE PROJECT, INCLUDING WHEN LOOPS OR OTHER DETECTION DEVICES ARE DAMAGED. THE USE OF MICROWAVE DETECTORS OR THE INSTALLATION OF NEW LOOPS WITHIN 48 HOURS OF DAMAGE SHALL BE MADE FOR FULL DETECTOR ACTUATION UNTIL THE PROPOSED VIDEO
DETECTION IS ACTIVATED.
2. UNLESS OTHERWISE NOTED, ALL REMOVED AND SURPLUS EQUIPMENT SHALL BE DELIVERED TO THE PINELLAS COUNTY TRAFFIC SIGNAL SHOP, BETWEEN 6:30 AM AND 4:30 PM MONDAY THRU THURSDAY, LOCATED AT 22211 US 19 NORTH, CLEARWATER, FL 33765. PROVIDE A MINIMUM FORTY-EIGHT HOURS NOTICE PRIOR TO DELIVERY. THE CONTACT PHONE
NUMBER IS (727) 464-8922.
3. THROUGHOUT THE ENTIRE PROJECT, MAINTAIN COMMUNICATIONS BETWEEN THE COMPUTERIZED SIGNAL SYSTEM, THE INTERSECTION AND ADJACENT INTERSECTIONS (WHERE APPLICABLE) VIA INTERCONNECT CABLE AND BE RESPONSIBLE FOR ANY ADDITIONAL COST RELATED TO MAINTAIN THE COMMUNICATIONS. CONTACT PINELLAS COUNTY TRAFFIC ENGINEERING ONE WEEK PRIOR TO ANY WORK WHICH MAY CAUSE DISRUPTION OF COMMUNICATIONS.
FIELD VERIFICATION AND ADJUSTMENTS:
1. ADJUST EQUIPMENT OR COMMUNICATION INFRASTRUCTURE FROM LOCATIONS SHOWN ON THE PLANS WHEN NECESSARY
DUE TO FIELD CONDITIONS AFTER APPROVAL FROM THE ENGINEER. ANY DEVIATIONS FROM THE CONSTRUCTION
DOCUMENTS SHALL BE RECORDED ON THE AS-BUILT PLANS AND TABULATION SHEETS.
GENERAL CONSTRUCTION:
1. RETURN ALL DISTURBED AREAS TO PRECONSTRUCTION CONDITIONS WITHIN 72 HOURS OF THE CONSTRUCTION ACTIVITY.
THIS INCLUDES RESTORATION OF GRADE AND SODDING FOR STABILIZATION AND WATERING OF THE SOD UNTIL IT HAS
TAKEN ROOT.
2. ALL REFERENCES IN THE PLANS TO RIGID CONDUIT SHALL BE INSTALLED AS RIGID GALVANIZED STEEL CONDUIT (RGSC).
ALL HARDWARE REQUIRED TO OFFSET THE RIGID CONDUIT FROM EXISTING INFRASTRUCTURE SHALL BE OF SIMILAR
MATERIALS TO PREVENT CATHODIC REACTIONS.
3. FURNISH THE INSPECTOR AND PINELLAS COUNTY TRAFFIC SIGNAL SHOP THREE COMPLETE SETS OF AS-BUILT PLANS, BORE LOGS AND RESISTANCE READINGS OF BOTH LOOPS AND GROUND RODS PRIOR TO FINAL INSPECTION OF THE PROJECT. PLANS MUST INCLUDE DEPTH AND OFFSET OF ALL CABLES INSTALLED. IN ADDITION, SUBMIT ONE SET OF COMPLETE AS-BUILT PLANS TO BOTH FDOT DISTRICT SEVEN TRAFFIC OPERATIONS AND FDOT PINELLAS MAINTENANCE.
SEND A WRITTEN REQUEST TO PINELLAS COUNTY TRAFFIC ENGINEERING TO TRANSFER MAINTENANCE FROM THE
CONTRACTOR TO THE COUNTY UPON PASSING THE FINAL INSPECTION.
4. IF SIDEWALK IS DAMAGED OR REMOVED DURING THE COURSE OF CONSTRUCTION, THE CONTRACTOR SHALL REPLACE THE ENTIRE SIDEWALK SLAB FROM EXPANSION JOINT TO EXPANSION JOINT AT THE CONTRACTOR'S EXPENSE. SIDEWALK
DISTURBED DURING CONSTRUCTION SHALL BE RESTORED WITHIN 72 HOURS.
5. SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW FOR ALL EQUIPMENT AND MATERIALS FURNISHED AND INSTALLED. FURNISH COPIES OF ALL DRAWINGS, SCHEDULES, AND COMPLETE DESCRIPTIVE AND TECHNICAL DATA ON
ALL ITEMS.
6. THE ACCEPTANCE OF ANY SUBMITTED DATA FOR MATERIALS, EQUIPMENT, APPARATUS, DEVICES, ARRANGEMENTS, AND/OR LAYOUTS SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF PLACING PROPER DIMENSIONS, CAPACITIES, SIZES, QUANTITIES, AND INSTALLATION DETAILS TO EFFICIENTLY PERFORM THE REQUIREMENT AND INTENT OF THE CONTRACT. SUCH ACCEPTANCE SHALL NOT RELIEVE THE CONTRACTOR FROM
RESPONSIBILITY FOR ERRORS OR ANY SORT ON THE SUBMITTAL FORM.
7. THE CONTRACTOR'S ATTENTION IS DIRECTED TO THE FACT THAT ALL CONSTRUCTION ACTIVITIES SHALL CONFORM TO PINELLAS COUNTY CODE CHAPTER 58, ENVIRONMENT, ARTICLE XII - NOISE, SECTION 58-441 THROUGH 58-454.
8. ANY DAMAGE TO PINELLAS COUNTY OR FDOT INFRASTRUCTURE RESULTING FROM THE PROPOSED DIRECTIONAL DRILLING MUST BE REPAIRED BY THE CONTRACTOR IMMEDIATELY FOLLOWING THE DAMAGING EVENT AT THE
CONTRACTOR'S EXPENSE.
UTILITIES:
1. THE LOCATION OF UTILITIES SHOWN IN THE PLANS IS APPROXIMATE. THE EXACT LOCATION SHALL BE DETERMINED
BY THE CONTRACTOR, AT HIS EXPENSE AND IN COORDINATION WITH UNDERGROUND AND OVERHEAD UTILITY OWNERS PRIOR TO DIGGING OR ANY DIRECTIONAL BORE EFFORTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL UTILITY NOTIFICATIONS AND COORDINATION WITH UTILITY OWNERS FOR ANY ADJUSTMENTS THAT MAY BE NECESSARY TO RESOLVE ANY CONFLICTS THAT MAY ARISE BETWEEN THE CONTRACTORS ACTIVITIES AND EXISTING UTILITY LOCATIONS. A CONTRACTORS REPRESENTATIVE SHALL BE PRESENT WHEN THE UTILITY OWNERS LOCATE THEIR FACILITIES. NOTIFY THE APPROPRIATE UTILITY OWNERS AT LEAST 72-HOURS IN ADVANCE OF FOUNDATION OR POLE SETTING OPERATIONS WHERE CONFLICT WITH OVERHEAD OR UNDERGROUND UTILITIES IS POSSIBLE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGE TO EXISTING UTILITIES DURING CONSTRUCTION. THE COSTS ASSOCIATED WITH UTILITY COORDINATION AND UTILITY LOCATING SHALL BE INCLUDED IN MOBILIZATION.
2. FDOT DOES NOT LOCATE THEIR DRAINAGE STRUCTURES AS PART OF SUNSHINE ONE CALL. VERIFY EXISTING UNDERDRAIN AT STORM STRUCTURES WITH FDOT MAINTENANCE PERSONNEL. MAINTAIN A MINIMUM OF TWO-FOOT
CLEARANCE FROM THE UNDERDRAIN FILTER MATERIAL, PARALLEL AND CROSSING.
3. ALL INFRASTRUCTURE INSTALLED WITHIN THE RIGHT-OF-WAY SHALL BE IN ACCORDANCE WITH PRACTICES
REFERENCED IN THE LATEST FDOT UTILITY ACCOMMODATIONS MANUAL.
4. CONTACT THE POWER UTILITY PROVIDING ELECTRICAL SERVICE TO DETERMINE IF A SERVICE PROCESSING FEE OR SPECIAL IMPACT CONNECTION FEES ARE CHARGED BY THE UTILITY FOR ELECTRICAL SERVICE CONNECTION.
5. AS PART OF THE PAYMENT FOR ELECTRICAL POWER SERVICE ASSEMBLY, OBTAIN A PERMIT AND INSPECTION OF THE ELECTRICAL SERVICE. ALL PERMIT FEES SHALL BE INCLUDED IN THE POWER SERVICE ASSEMBLY COST. THE METER BASE SHALL INCLUDE A BYPASS HANDLE TO ALLOW CONTINUOUS VOLTAGE UNDER METER CHANGE OUT.
6. ALL UTILITIES IDENTIFIED IN A UTILITY RELOCATION SCHEDULE INTERFERING WITH CONSTRUCTION WILL BE REMOVED, RELOCATED, OR ADJUSTED BY THEIR RESPECTIVE OWNER AT THEIR EXPENSE. THE CONTRACTOR SHALL
COORDINATE WITH THE UTILITY OWNERS UPON AWARD OF THE CONTRACT TO ENSURE UTILITY
ADJUSTMENTS/RELOCATIONS ARE SCHEDULED OR COMPLETE. THE CONTRACTOR SHALL COORDINATE WITH THE UTILITY OWNERS THROUGHOUT THE DURATION OF THE PROJECT AND ENSURE ALL POTENTIAL CONFLICTS ARE ADDRESSED SO
AS NOT TO DELAY THE PROJECT.
7. CONTACT THE LOCAL POWER COMPANY FOR THEIR ASSISTANCE IN PERFORMING ALL NECESSARY WORK IN CLOSE PROXIMITY TO POWER LINES AND MEET ALL APPLICABLE OSHA AND NESC REQUIREMENTS REGARDING CLEARANCE FROM POWER LINES AND EQUIPMENT GROUNDING. THE TYPE OF EQUIPMENT USED WHEN WORKING UNDER OVERHEAD
UTILITIES SHALL MEET THE FOLLOWING REQUIREMENTS:
A. OVERHEAD LINES SHALL STAY IN PLACE BOTH VERTICALLY AND HORIZONTALLY
B. ANY COSTS ASSOCIATED WITH THE TYPE OF EQUIPMENT AND COORDINATION REQUIRED FOR THIS INSTALLATION IS
INCLUDED IN THE RELATED STRUCTURE OR DEVICE PAY ITEMS
C. WORK WITH POWER UTILITY TO DE-ENERGIZE LINES WHEN NECESSARY.
8. THE CONTRACTOR SHALL FIELD VERIFY LOCATION AND DEPTH OF PINELLAS COUNTY UTILITY LINES AT THE POINT OF CROSSING WITH THE DIRECTIONAL BORE TO PREVENT DAMAGE TO PINELLAS COUNTY UTILITIES.
9. MINIMUM 12” VERTICAL SEPARATION BETWEEN A COUNTY UTILITY AND PROPOSED CONDUITS.
10. PERFORM SUBSURFACE UTILITY ENGINEERING (SUE) AT EACH FOUNDATION. THE SUE EFFORT SHALL BE QUALITY
LEVEL A. THE COST TO PERFORM THIS ACTIVITY SHALL BE INCLUDED IN THE MAST ARM PAY ITEM.
PAY ITEM NOTES:
102-1000:
SHALL INCLUDE THE COST FOR ALL TRAFFIC CONTROL RELATED PAY ITEMS INCLUDING THOSE REQUIRED BY THE FDOT STANDARD PLANS INDEX 102 SERIES. THIS PAY ITEM SHALL ALSO INCLUDE ALL COSTS TO MAINTAIN ALL TRAFFIC SIGNALIZATION INCLUDING VEHICLE ACTUATION AND PEDESTRIAN SIGNAL OPERATIONS, UNLESS OTHERWISE SHOWN IN
THE PLANS.
630-2-11, 630-2-12:
NO TEST BORINGS WERE MADE WHERE CONDUIT RUNS ARE TO BE INSTALLED. ALL CONDUIT RUNS SHOWN ON THE PLANS
ARE SCHEMATIC AND FIELD ADJUSTMENTS MAY BE NECESSARY.
633-2-31:
UNLESS NOTED OTHERWISE, DROP FIBER SPLICE ENCLOSURES AND TRAYS AS REQUIRED BY THIS CONTRACT SHALL BE
SIZED TO ACCOMMODATE A MINIMUM OF 24 SPLICES.
633-3-35C:
THESE PAY ITEMS SHALL INCLUDE THE COST OF THE FIBER OPTIC DROP CABLES. THE DROP CABLES SHALL BE 12 COUNT. THE CONTRACTOR MAY SUBMIT ANOTHER PRODUCT THAT INCLUDES 12 COUNT FIBER AND PATCH PANEL WITH DUPLEX ST CONNECTORS IN PLACE OF THE PRE-TERMINATED PATCH PANEL. THE SIZE SHALL NOT EXCEED THAT OF THE FACTORY PRE-TERMINATED PATCH CABLE/PANEL, AND SHALL INCLUDE A SMALL FORM MOUNT AND SHALL BE REVIEWED AND APPROVED BY THE ENGINEER. THE COST FOR EACH PRE-TERMINATED DROP CABLE SHALL INCLUDE TWO DUPLEX FIBER PATCH CABLES. EACH PATCH CABLE SHALL BE THREE FEET LONG AND HAVE ST CONNECTORS ON ONE
END AND LC CONNECTORS ON THE OTHER.
TRAFFIC CONTROL PLAN NOTES:
1. MAINTAIN TRAFFIC ON THE EXISTING ROADWAY BY USE OF THE FDOT FY 2022-23 STANDARD PLANS FOR ROAD AND BRIDGE CONSTRUCTION, INDEX NUMBERS 102-600 THROUGH 102-670 AS APPROPRIATE FOR THE WORK BEING
PERFORMED
2. DURING NON-WORKING HOURS NO EQUIPMENT, VEHICLES OR MATERIALS SHALL BE PARKED OR STORED WITHIN THE
CLEAR ZONE OF ANY ROADWAY.
3. REGULATORY SPEEDS SHALL BE THE SAME AS THE EXISTING POSTED SPEEDS THROUGH THE PROJECT LIMITS.
4. GROUND MOUNTED SIGNS MAY BE USED IN LIEU OF POST MOUNTED SIGNS ONLY IF CONSTRUCTION OPERATION WILL NOT EXCEED A 12-HOUR PERIOD. SIGNS ARE TO BE IN ACCORDANCE WITH THE FDOT STANDARD PLANS INDEX 102-600
SERIES AND AS SPECIFIED IN THE MUTCD.
5. A LANE CLOSURE SHALL BE REQUIRED WHENEVER A BOOM ARM OR BUCKET CROSSES A TRAVEL LANE. THIS ALSO APPLIES TO INSTALLING STRUCTURE COMPONENTS AND EQUIPMENT OVER THE TRAVEL LANES. ALL WORK REQUIRING A LANE CLOSURE SHALL BE DONE BETWEEN 10:00 PM AND 6:00 AM. THIS TIME FRAME MAY BE FURTHER LIMITED BY
SPECIAL EVENTS OR HOLIDAYS AS OUTLINED IN THE SPECIFICATIONS.
A.THE CONTRACTOR SHALL, AT THE DISCRETION OF THE ENGINEER, OPEN ANY TEMPORARY LANE CLOSURE CAUSING EXTENDED TRAFFIC CONGESTION (5-MINUTE DELAY) UNTIL TRAFFIC HAS RETURNED TO AN ACCEPTABLE FLOW AS
DETERMINED BY THE ENGINEER.
B. THE CONTRACTOR SHALL NOTIFY THE ENGINEER A MINIMUM OF 48-HOURS IN ADVANCE OF ANY LANE CLOSURES.
C. DURING PERIODS OF LANE CLOSURES THE CONTRACTOR SHALL PROVIDE DEDICATED CREW FOR THE INSTALLATION, MAINTENANCE AND REMOVAL OF THE TRAFFIC CONTROL DEVICES, BARRICADES, SIGNS, ARROW BOARDS, ETC. THIS CREW SHALL CONSIST OF AT LEAST THREE MEMBERS OF THE CONTRACTOR'S WORK FORCE WHOSE SOLE RESPONSIBILITY SHALL BE THE MAINTENANCE OF TRAFFIC CONTROL. THE CONTRACTOR SHALL FURNISH A WORK
VEHICLE TO AID IN MAINTAINING THE CONTROL DEVICES.
D. THE CONTRACTOR SHALL BE REQUIRED TO SUBMIT A WRITTEN PLAN WHICH DETAILS EACH ACTIVITY INVOLVED IN THE LANE CLOSURE. THE PLAN SHALL INCLUDE BACK-UP PLANS FOR ACTIVITIES CRITICAL TO RE-OPENING THE LANES TO TRAFFIC. THE BACK-UP PLAN SHALL INCLUDE THE ACTIVITIES OF ALL SUBCONTRACTOR'S OPERATIONS AS WELL AS THE PRIME CONTRACTOR'S. NO LANE CLOSURE WILL BE ALLOWED WITHOUT A PLAN TO ACHIEVE RE-OPENING.
E. LANE CLOSURES SHALL NOT BE PERFORMED DURING HOLIDAY PERIODS AS LISTED IN THE SPECIFICATIONS AND WEDNESDAY NIGHT PRIOR TO THANKSGIVING DAY. IN ADDITION TO THESE AND PREVIOUSLY SPECIFIED LIMITATIONS ON LANE CLOSURES, THE COUNTY MAY DEFINE ADDITIONAL DAYS WHEN NO LANE CLOSURES WILL BE PERMITTED. THE CONTRACTOR WILL BE PROVIDED NO LESS THAN 7 DAYS NOTICE OF THESE EVENTS AND THEY SHALL BE AT NO
ADDITIONAL COSTS OR TIME TO THE COUNTY.
F. THERE WILL BE NO LANE CLOSURES OR SIGNAL SHUTDOWNS ON COUNTY ROADS MONDAY THROUGH FRIDAY BETWEEN
6:00 AM AND 10:00 PM.
G. THE CONTRACTOR IS ALERTED THAT CITY ROAD AND STATE ROADS MAY HAVE DIFFERENT TIME PERIOD RESTRICTING LANE CLOSURES. THE CITY AND STATE PERMITS, IF NECESSARY, WILL STIPULATE THESE TIMES.
H. THE CONTRACT WILL BE PERMITTED TO WORK IN THE ROADWAY DURING ALL OTHER PERIODS, UNLESS INFORMED OTHERWISE BY THE ENGINEER. FULL TRAFFIC CAPACITY AND SIGNAL OPERATION SHALL BE RESTORED BY THE CONTRACTOR AT THE END OF EACH WORKDAY. IN NO CASE SHALL THE CONTRACTOR CLOSE MORE THAN ONE LANE
WITHOUT PRIOR APPROVAL OF THE ENGINEER.
6. THE CONTRACTOR SHALL PROVIDE FOR THE SAFE MOVEMENT OF VEHICLES AND PEDESTRIANS THROUGHOUT ALL PHASES OF CONSTRUCTION, INCLUDING DELIVERIES AND DROP-OFFS IN WORK ZONES. THE CONTRACTOR SHALL FURNISH, ERECT, AND MAINTAIN ANY AND ALL NECESSARY TRAFFIC CONTROL AND SAFETY DEVICES IN ACCORDANCE WITH THE FEDERAL HIGHWAY ADMINISTRATION'S MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES.
7. THE CONTRACTOR SHALL MAINTAIN PEDESTRIAN PATHWAYS WITHIN THE PROJECT LIMITS AT ALL TIMES THROUGHOUT ALL PHASES OF CONSTRUCTION. THE CONTRACTOR SHALL NOT STORE ANY EQUIPMENT, MATERIALS, DEBRIS, OR EXCAVATION ON THE SIDEWALK OR WITHIN THE PEDESTRIAN PATHWAY. ALL PEDESTRIAN DETOURS SHALL BE SIGNED
IN ACCORDANCE WITH FDOT STANDARD PLANS INDEX 102-660.
8. THE CONTRACTOR SHALL NOTIFY LOCAL LAW ENFORCEMENT OF ANY LANE CLOSURES THAT MAY EXIST LONGER THAN
TWO HOURS. ALL LANE CLOSURES SHALL BE APPROVED BY THE ENGINEER.
UTILITY OWNERS:
COMPANY CONTACT PERSON CONTACT NUMBER
1. CLEARWATER GAS SYSTEM JACINTA GARCIA CORCOBA (727) 422-9998
2. DUKE ENERGY- ST PETE STEPHANIE OLMO (407) 905-3376
3. FRONTIER COMMUNICATIONS TONI CANNON (813) 875-1014
4. KNOLOGY BROADBAND OF FL RICHARD LAGANGA (727) 422-8040
5. CENTURYLINK NETWORK RELATIONS (877) 366-8344 X2
6. CHARTER COMMUNCATIONS JEREMY CORNETTE (863) 581-5734
7. PINELLAS COUNTY UTILITIES-SEWER TREVOR SINGH (727) 464-3536
8. PINELLAS COUNTY UTILITIES-RECLAIM TREVOR SINGH (727) 464-3536
9. PINELLAS COUNTY UTILITIES-WATER TREVOR SINGH (727) 464-3536
10. PINELLAS COUNTY - HWY/ENG JAMES JOHNSON (727) 464-8981
11. UNITI FIBER LLC BOB MENSCHING (904) 718-8152
182181180179
TRAFFIC SIGNAL / PINELLAS COUNTY
TR
A
FF
IC
S
IG
N A L
PI
N
EL
LA
S
C O U N
TY
ATMS / PINELLAS COUNTY
TO LOOP
TO LOOP A
TM
S
PI
N
EL
LA
S
C O U N
TY
A
TM
S
PI
N
EL
LA
S
C O U N
TY
TR
A
FF
IC
S
IG
N A L
PI
N
EL
LA
S
C O U N
TY
TRAFFIC SIGNAL /PINELLAS COUNTY
TRAFFIC SIGNAL /
PINELLAS COUNTY
TR
A
FF
IC
S
IG
N A L
PI
N
EL
LA
S
C O U N
TY
SA
N
IT
A R Y
FO
R C E
M A
IN
PI
N
EL
LA
S
C O U N
TY
STA.
POLE LOCATION=
GND ELEV
FDN ELEV
180+81.42
69.42 LT.
1 34.50'
I V-4
FDN ELEV
173+92.73
65.98 RT.
2 32.30' I
V-2
I
V-1
I
V-3
4 4R7 4
338 8
C
D
A
B
P8 P6
P6
P4
P4
P2P2
EL. 34.96'
EL. 33.80'
EL. 32.78'
EL. 33.78'
P8
Arm-1
Arm-2
Arm-1
Arm-2
E
35.00'
32.80'
Feet 40200 10
PED. SIGNAL
COUNT-DOWN
1-SECT., 1-WAY
8 AS
ALL RED
YELLOW CLEARANCE
MAXIMUM GREEN 2
RECALL
PED. CLEARANCE
PEDESTRIAN WALK
MAXIMUM GREEN 1
MOVEMENT NUMBER
TIMING FUNCTION
EXISTING CONTROLLER TIMINGS
TI
M
IN
G F U N C
TI
ON
EXTENSION
MINIMUM GREEN
SIGNAL HEAD DETAILS
P2
P6
A
B
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
653-1-11
3-SECT., 1-WAY3-SECT., 1-WAY
8 AS
650-1-14
R
Y
G
NOTES:
1. MAJOR STREET IS TAMPA RD (MOVEMENTS 1, 5, 2, & 6). MINOR STREET IS LAKE SAINT GEORGE DR (MOVEMENTS 3, 4, 7, & 8).
2. FLASHING OPERATION IS YELLOW FOR MAIN STREET THROUGH MOVEMENTS AND RED FOR MAJOR STREET LEFT TURN AND ALL MINOR STREET MOVEMENTS.
3. FOR OVERHEAD INTERNALLY ILLUMINATED STREET NAME SIGN DETAILS SEE SHEET TE-8.
4. EACH PHASE/MOVEMENT SHALL BE WIRED FROM THE SIGNAL DISPLAY TO THE CONTROLLER AS A SEPARATE PHASE/MOVEMENT. THIS INCLUDES LEFT TURN MOVEMENTS. EACH LEFT TURN MOVEMENT SHALL HAVE CONDUCTORS AVAILABLE FOR PROTECTED AND PERMISSIVE OPERATION.
5. ELEVATIONS SHOWN AT THE BASE OF THE MAST ARM POLES ARE GROUND ELEVATIONS AND TOP OF FOUNDATION ELEVATIONS MEASURED AT THE CENTER OF
THE FOUNDATION.
6. EXISTING SOP AND TIMINGS TO REMAIN.
7. THE CONTRACTOR SHALL SOFT DIG AT THE LOCATION OF THE SE MAST ARM AND VERIFY THAT THE MAST ARM FOUNDATION WILL NOT IMPACT THE NEARBY
PINELLAS COUNTY UTILITIES.
8. THE CONTRACTOR SHALL SOFT DIG AT THE LOCATION OF THE NW AND NE PEDESTRIAN SIGNAL POLE FOUNDATION WILL NOT IMPACT THE NEARBY PINELLAS
COUNTY UTILITIES. THE UTILITY SHALL BE PROTECTED DURING CONSTRUCTION.
9. FOR THE PROPOSED CURB AND GUTTER NEAR THE CURB RAMPS, REMOVE AND RECONSTRUCT THE CURB AND GUTTER PORTION ADJACENT TO THE RAMP TO MAKE THE AREA IN FRONT OF THE RAMP A FLAT TRANSITION. THE NEW GUTTER NEEDS TO MEET ADA STANDARDS WHILE MAINTAINING EXISTING GRADE
FOR STORMWATER FLOW.
10. FOR THE PROPOSED FIBER PULL BOX AT THE NORTHEAST CORNER, DIG AND INTERCEPT EXISTING ATMS 2" CONDUIT. CUT CONDUIT RUN AND BRING UP CONDUIT FROM THE EAST INTO PROPOSED PULL BOX AND KEEP WITHIN EASEMENT LINES. CONDUIT WEST OF THIS PULL BOX WILL BE PROPOSED AND CONDUIT EAST OF THIS PULL BOX WILL REMAIN EXISTING. SEE SPLICE DIAGRAM FOR MORE DETAILS.
11. CUT FIBER TRUNKLINE INSIDE NORTHEAST CORNER SPLICE VAULT ON THE WEST SIDE OF THE EXISTING SPLICE TO THE CCTV. PULL FIBER TRUNKLINE FROM NORTHWEST CORNER SPLICE VAULT. THEN REROUTE FIBER THROUGH PROPOSED CONDUIT PATH BACK TO NORTHEAST CORNER SPLICE VAULT. SPLICE
THE DROP FROM THE TRAFFIC CABINET AND SPLICE THE OTHER FIBERS COLOR TO COLOR.
4 AS
650-1-14
Y
G
R
P4
P8
7 12 7 12
4.8 4.8 4.8 4.83.7 3.7
4.2 4.1 4.1
23 353523
2.0 4.2 2.0
MIN MIN
5 10 5 101515
4 4 3 43 3
20 60 40 15 60 60
2060 6040 40
(1)
(3)
(2)
(2)
(2)
(2)
(2)
3.7 3.7
4.1 4.1
35 20
60 15
S.O.P. 10
P6
G G
Y Y
R
47 4R(1) (1)
(1)
(2)
(1)
P2
P6
P2
P8
P4
P8
P4
START CROSSING
Watch For Vehicles
DON'T START
Finish Crossing
If Started
TIME REMAINING
To Finish Crossing
DON'T CROSS
STEADY
TIMER
FLASHING
PUSH BUTTON
TO CROSS
FTP-68B-06
Tampa Rd
4 EA
V-1 V-2
VIDEO DETECTOR CHART
DETECTOR
NO.
V-3
START CROSSING
Watch For Vehicles
DON'T START
Finish Crossing
If Started
TIME REMAINING
To Finish Crossing
DON'T CROSS
STEADY
TIMER
FLASHING
PUSH BUTTON
TO CROSS
FTP-68B-06
Lake St George Dr
DZ-2, DZ-5
V-4
INTERNALLY ILLUMINATED
STREET NAME SIGNS
DZ-4,
DZ-3, DZ-8
DZ-1,
ZONE
4 EA
DZ-7
DZ-6
DZ-4R,
4 EA 700-5-22
5-SECT., 1-WAY
1 AS
650-1-19
4-SECT., 1-WAY
1 AS
650-1-16
FY
C
E
L-1 1 L-5
LOOPS NO. OF
LOOPS
NO OF
DETECTORS
L-2A
MOVEMENT DELAY TIME
(SEC.)CHANNEL NO.
L-6A
DETECTORS FOR LOOPS
L-2B
L-2C
L-6B
L-6C L-3A 3
L-4R 4R
L-3B
L-8
L-7
L-4
5 sec
*POLE 1: RELOCATE CONFLICTING (1) 1" TRAFFIC SIGNAL CONDUIT (2.15' DEPTH)
RELOCATE CONFLICTING (1) 1.25" GRAY PVC TRAFFIC SIGNAL CONDUIT (2.51' DEPTH)
RELOCATE CONFLICTING (2) 2" GRAY PVC ATMS CONDUIT (2.78' DEPTH)
**POLE 2: RELOCATE CONFLICTING (3, WITH 2 PIPES CUT) 2" GRAY TRAFFIC SIGNAL CONDUIT
(1.89'-2.11' DEPTH)
RELOCATE CONFLICTING 4" DARK GRAY PVC UNKNOWN CONDUIT (2.01'-2.32' DEPTH)
RELOCATE CONFLICTING PEDESTRIAN SIGNAL POLE
2 (3)
1 AS 700-11-391
SY
R
G
BLANK-OUT SIGN
D
4R
4R
SOIL
CLASSIFICATION
FRICTION
ANGLE (DEG)
SHEAR STRENGTH
(PSF)
STRUCTURE
ID
SPT 'N'
AVERAGE
SAT. UNIT
WEIGHT (PCF.)
SOIL PROPERTIES USED FOR DRILLED SHAFT DESIGN
FOUNDATION NOTES:
1. FOUNDATION DESIGN BASED ON DATA FROM BORINGS PERFORMED BY MC
2. FOR SOIL ASSUMPTIONS AND VALUES USED IN DESIGN, SEE FOUNDATION DATA TABLE. WATER
TABLE IS ASSUMED TO BE AT THE SOIL SURFACE.
3. THE CONTRACTOR SHOULD ANTICIPATE DIFFICULT DRILLED SHAFT INSTALLATION DUE TO THE
PRESENCE OF SATURATED, VERY LOOSE SANDY SOILS. THE PRESENCE OF DIFFICULT SOIL
CONDITIONS MAY OCCUR AT VARYING DEPTHS BELOW THE EXISTING GROUND SURFACE. THE
CONTRACTOR SHOULD ANTICIPATE POTENTIAL CAVE-IN OF THE SANDY SOILS, DIFFICULT
CONDITIONS TO RETAIN BENTONITE/POLYMER SLURRY INSIDE THE DRILLED HOLES DUE TO VERY
LOOSE SOIL CONDITIONS, AND POTENTIAL OVERRUNS OF CONCRETE WITHIN THE VERY LOOSE
ZONES.
4. LAYERS OF DENSE SAND MAY BE ENCOUNTERED AT THIS SITE. SUCH MATERIALS MAY MAKE
SHAFT EXCAVATION AND/OR TEMPORARY CASING INSTALLATION DIFFICULT. THE CONTRACTOR
SHALL EXPECT TO ENCOUNTER THESE TYPES OF MATERIALS AT THE SHAFT LOCATION AND
SHALL USE SPECIALIZED EQUIPMENT AND/OR PROCEDURES AS NECESSARY TO FACILITATE
SHAFT EXCAVATION AND/OR TEMPORARY CASING INSTALLATION. WHEN TEMPORARY CASING IS
USED, THE CASING TIP SHALL BE REINFORCED, AND THE CASING THICKNESS SHALL BE
ADEQUATE TO PREVENT CASING DAMAGE/DEFORMATION DURING INSTALLATION THROUGH HARD
LAYERS.
NOTES [Notes Date 11-01-16]:
1. IF AN ENTRY APPEARS IN COLUMN FAA, A SHORTER ARM IS REQUIRED. THIS IS OBTAINED BY REMOVING LENGTH FROM THE ARM TIP
AND THE ARM LENGTH SHORTENED FROM FA TO FAA. SAA SIMILAR.
2. IF AN ENTRY APPEARS IN COLUMN UAA, A SHORTER POLE IS REQUIRED. THIS IS OBTAINED BY REMOVING LENGTH FROM THE POLE TIP
AND THE POLE HEIGHT SHORTENED FROM UA TO UAA.
3. WORK THIS SHEET WITH THE SIGNAL DESIGNER’S “MAST ARM TABULATION”. SEE “MAST ARM TABULATION” FOR SPECIAL INSTRUCTIONS
THAT INCLUDE NON-STANDARD HANDHOLE LOCATION, PAINT COLOR, TERMINAL COMPARTMENT REQUIREMENT, AND PEDESTRIAN FEATURES.
4. WORK WITH 2022-23 DESIGN PLANS INDEX 649-030 AND 649-031.
5. MAST ARMS DESIGNED FOR FUTURE LUMINARIE.
UB
(ft.)
UAA
(ft.)
POLE
STANDARD MAST ARM ASSEMBLIES DATA TABLE
LL
(deg)
UF
(deg)
SECOND ARM
FAA
(ft.)
FIRST ARM
STRUCTURE
ID
NUMBERS
Table Date 11-01-16
DRILLED
SHAFT
ID
ARM
ID
DESIGNATION
POLE
ID
SAA
(ft.)
ARM
ID
A78/D - A70/D -
P6/D
A78/D A70/D P6/D 20.50 DS/20/567
21.00 DS/25/5
A78/D - A70/D -
P6/D
A78/D A70/D P6/D67
SAND 16 33 N/A 48.49
SAND 11 31 N/A 43.74
ARM NO. 2 - DOUBLE ARM POLE ORIENTATION
TO BE MEASURED IN A COUNTER CLOCKWISE
DIRECTION FROM ROADWAY ARM NO. 1.
ARM NO. 1 - SINGLE ARM POLE OR
LONGEST ARM FOR DOUBLE ARM POLE.
ARM
MOUNTING
HEIGHT
(ARM M.H.)
TOP OF FOUNDATION ELEVATIONTOTAL ARM LENGTH
DEVICE ADEVICE B
S
IG
N E
DEVICE CSIGN D
AH5E D C
H4
124 3
W3 W2W4
W5
B H3 H2
W1
H1
PAINT
COLOR* *3 W11 *
DEVICE DATA
2* 4 H1A
LOCATION
BY STA.
ARM
M.H.
DISTANCE FROM POLE / HEIGHT AND WIDTH OF DEVICEDISTANCE FROM POLE
* DENOTES NUMBER OF SECTIONS IN SIGNAL HEAD ASSEMBLY
SIGNAL DATA
SHEET
NO.
ID
NO.
TOP OF
FOUNDATION
ELEVATION
RDWY
ARM
NO.
CROWN
ELEV.
SIGNAL
V/H
BACK
PLATES
Y/N
PED.
SIGNAL
Y/N
TOTAL
ARM
LENGTH
∡ BETWEEN
DUAL ARMS
90/270
V Y N 58.0' 69.5'5 3 78.0'1 TE-6 9033.78'180+81.42, 69.42 LT. 35.00' 20.5' N/A
V Y N 29.0' 40.0' 51.0'3 3 3 67.0'34.96' 20.5'
W2H2B W3H3C
2.0' 2.0'
8.0'
7.0'20.9' - IISNS
43.0' - VVDS
61.5' - PREEMPT 66.0' - VVDS1.0' 0.5' 1.8' 0.7'
*5 *6 W4H4D E W5H5
1 V Y N 55.1' 65.7' 71.3'3 3 3 78.0'2 TE-6 33.80'173+92.73, 65.98 RT. 32.80' 21.0'77.0' 3
32.1' 43.1' 54.1'3 3 3 67.0' 21.0'65.1' 3
21.6' - IISNS 37.4' - PREEMPT62.0' 3
40.0' - IISNS
25.0' - IISNS
62.4' - PREEMPT
46.9' - PREEMPT 49.9' - VVDS
69.0' - VVDS
N/A N/A N/A
2.0' 7.0' 2.0' 8.0'
1.0' 0.5' 1.0' 0.5' 1.0' 0.5'
1.8' 0.7' 1.8' 0.7' 1.8' 0.7'2 V Y N32.78'
75.0' 4 72.3' - BLANKOUT2.4' 2.4'
Feet
20 40
A
C
D
B
I
I
B-5 B-6
B-7
B-8
L a k e
S t
G e o r g e
D r
Tampa Rd.
LEGEND
GRANULAR MATERIALS- RELATIVE DENSITY
VERY LOOSE
LOOSE
MEDIUM
DENSE
VERY DENSE
£ 4
4-10
10-30
30-50
GREATER THAN 50
SILTS AND CLAYS CONSISTENCY
VERY SOFT
SOFT
FIRM
STIFF
VERY STIFF
HARD
£ 2
2-4
4-8
8-15
15-30
GREATER THAN 30
SAFETY HAMMER SPT N-VALUE (BLOWS/FT)
(SC) Clayey fine SAND
N SPT N-VALUE
NMC NATURAL MOISTURE CONTENT (%)
-200 FINES PASSING A NO. 200 SIEVE (%)
GNA GROUNDWATER NOT APPARENT
HA HAND AUGER BORING
LL LIQUID LIMIT
PI PLASTICITY INDEX
OC ORGANIC CONTENT
SAFETY HAMMER SPT N-VALUE (BLOWS/FT)
WATER TABLE EXISTING
AT TIME OF BORING
(SP) Poorly-graded fine SAND
LOC LOSS OF CIRCULATION
WOH WEIGHT OF HAMMER
(SP-SM) Poorly-graded fine SAND with silt
(CH) Fat CLAY
(CL) Lean CLAY
(SP-SC) Poorly graded
SAND with clay
D E
P T
H
F
E E
T
BORING NO. B-5
DATE 10/7/21
Boring Terminated at 25 ft.
HA
N
GNA
NMC: 4.3%
-200: 2.4%
D E
P T
H
F
E E
T
20 20
BORING NO. B-6
DATE 10/7/21
BORING NO. B-7
DATE 10/6/21
BORING NO. B-8
DATE 10/6/21
Boring Terminated at 25 ft. Boring Terminated at 25 ft. Boring Terminated at 25 ft.
N N N
HA
HA
HA
HA
HA HA HA
4 4
NMC: 3.8%
-200: 97.2%
LL: 101
PI: 80
NMC: 6%
-200: 14.8%
NMC: 2.2%
-200: 7.7%
GNA GNA GNA
No Recovery, Material assumed same as above
Medium dense, light brownish gray, poorly graded
SAND with silt (SP-SM)
Very loose to loose, dark gray to yellowish brown, poorly graded SAND (SP)
Very loose to loose, dark gray to yellowish brown, poorly graded SAND (SP)
Medium dense to dense, light brownish gray, poorly graded
SAND with clay (SP-SC)
Loose, light gray, clayey SAND (SC)
Medium dense, yellowish brown, poorly graded
SAND with silt (SP-SM)
Very loose to loose, dark gray to yellowish brown, poorly graded SAND (SP)
Firm to stiff, light gray, fat CLAY (CH)
Firm to very stiff, light greenish gray, fat CLAY (CH)
Medium dense, light gray, poorly graded
SAND with silt (SP-SM)
Very loose to loose, dark gray to yellowish brown, poorly graded SAND (SP)
NAMEDATE APPROVED BY:REVISION
SUPERVISED BY:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
SHEET NO.MC PROJ. NO.
DATE
NAME
5808-A Breckenridge Parkway
Tampa, FL 33610
Ph:813-623-3399 Fax:813-623-6636
Geotechnical Consultants
MC SQUARED, INC.
JF
KF
KF
JF
FLORIDA ENGINEERING CERTIFICATE OF
AUTHORIZATION No. 9191
Jordan Fox, P.E.
FLORIDA LICENSE No. 87472
LEGEND:
Plan Provided By: HNTB
Approximate Boring Location
Report of Core Borings (Tampa Rd and Lake St George Dr)
10/14/2021
10/14/2021
11/29/2021 T022102.009
Pinellas Intersection Improvements
Pinellas County, FL
ES-1 178+12.99 4.43' LT. RIM = 38.50
INV. W (18" RCP) = 30.04
INV. E (18" RCP) = 30.03
ACP 302 1357868.978 422913.150 SET 5/8" CAPPED IRON ROD "TP-RP LB 6429"38.24 178+46.28 51.67' RT. TAMPA ACP 306 1357977.028 423065.947 SET MAG NAIL & DISK "TP-RP LB 6429"35.86 180+00.51 54.34' LT. TAMPA
ACP 305 1357874.648 423104.483 SET MAG NAIL & DISK "TP-RP LB 6429"35.56 180+37.67 48.55' RT. TAMPA
ACP 311 1357972.188 423339.565 SET 5/8" CAPPED IRON ROD "TP-RP LB 6429"31.97 182+71.00 51.33' LT. TAMPA ACP 310 1357869.004 423362.353 SET 5/8" CAPPED IRON ROD "TP-RP LB 6429"29.32 182+99.21 50.51' RT. TAMPA
ACP 309 1357788.305 423242.205 SET MAG NAIL & DISK "TP-RP LB 6429"34.41 48+63.55 38.71' RT. LAKE ACP 308 1357810.010 423165.713 SET MAG NAIL & DISK "TP-RP LB 6429"34.67 48+86.29 37.48' LT. LAKE ACP 301 1358004.263 423159.237 SET MAG NAIL & DISK "TP-RP LB 6429"33.18 50+80.61 41.33' LT. LAKE
ACP 300 1358231.024 423225.593 SET 5/8" CAPPED IRON ROD "TP-RP LB 6429"24.26 53+06.45 28.08' RT. LAKE
ACP 303 1357537.880 423246.100 SET 5/8" CAPPED IRON ROD "TP-RP LB 6429"35.35 N/A N/A N/A ACP 304 1357836.093 423655.275 SET MAG NAIL & DISK "TP-RP LB 6429"21.79 N/A N/A N/A
ES-2 180+54.20 9.09' LT. RIM = 35.98
INV. W (18" RCP) = 28.99
INV. E (24" RCP) = 25.78
INV. S (18" RCP) = 25.66
INV. N (18" RCP) = 31.49
ES-3 180+50.79 43.57' RT. TOP = 35.20
INV. N (18" RCP) = 30.16
INV. E (6" PLASTIC) = 30.70
ES-4 180+51.41 51.13' LT. TOP = 35.30
INV. S (18" RCP) = 32.04
INV. E (6" PVC) = 33.27
ES-5 49+02.54 29.82' LT. TOP = 32.65
INV. E (18" RCP) = 29.08
ES-6 49+01.27 29.16' RT. TOP = 33.46
INV. W (18" RCP) = 28.61
INV. N (18" RCP) = 28.56
ES-7 182+22.52 44.48' RT. TOP = 31.03
INV. N (18" RCP) = 25.69
INV. E (6" PVC) = 25.62
ES-8 184+02.23 53.62' RT. GRATE = 25.70
INV. E (18" RCP) = 19.68
INV. SW (24" RCP) = 21.64
ES-9 182+25.86 1.32' RT. RIM = 31.90
INV. S (18" RCP) = 25.01
INV. W (24" RCP) = 24.98
INV. E (24" RCP) = 25.02
INV. E (6" PVC) = 27.55
ES-10 53+25.67 19.06' LT. RIM = 23.29
INV. E (18"RCP) = 18.87
INV. S (6" PVC) = 20.39
INV. N (6" PVC) = 20.37
ES-11 53+24.37 16.90' RT. RIM = 23.37
INV. W (18" RCP) = 18.44
INV. N (18" RCP) = 18.37
INV. S (6" PVC) = 18.88
Beginning chain TAMPA description Point 100 N 1,357,920.1035 E 422,872.3611 Sta 178+06.18
Course from 100 to PC 1 N 89° 14' 08.18" E Dist 289.1799
Curve Data P.I. Station 182+74.34 N 1,357,926.3490 E 423,340.4770 Delta = 7° 08' 59.38" (RT) Degree = 2° 00' 00.02" Tangent = 178.9776 Length = 357.4905 Radius = 2,864.7820 External = 5.5854 Long Chord = 357.2586 Mid. Ord. = 5.5745 S. E. = 0.000 P.C. Station 180+95.36 N 1,357,923.9614 E 423,161.5154 P.T. Station 184+52.85 N 1,357,906.4437 E 423,518.3442 C.C. N 1,355,059.4343 E 423,199.7328 Back = N 89° 14' 08.25" E Ahead = S 83° 36' 52.37" E Chord Bear = S 87° 11' 22.06" E Ending chain TAMPA description Beginning chain LAKE description Point 103 N 1,357,571.2328 E 423,206.4274 Sta 46+46.98
Course from 103 to 104 N 0° 46' 28.03" W Dist 353.0151
Point 104 N 1,357,924.2156 E 423,201.6559 Sta 50+00.00
Course from 104 to 105 N 0° 46' 28.20" W Dist 345.5886
Point 105 N 1,358,269.7727 E 423,196.9845 Sta 53+45.58 Ending chain LAKE description
PROP 303 1357865.876 422555.832 FOUND 5/8" IRON ROD NO IDENTIFICATIONN/A 174+88.96 321.14' RT. TAMPA
PROP 305 1357868.621 422741.712 FOUND NAIL & DISK "LS 2512"N/A 176+74.86 140.43' RT. TAMPA
PROP 304 1357866.368 422616.117 FOUND NAIL & DISK "PLS 5052 KAI"N/A 175+49.24 261.82' RT. TAMPA
PROP 302 1357980.688 422908.336 FOUND PK NAIL AND DISK "LB 208 LLOVERAS"N/A 178+42.96 60.10' LT. TAMPA
DS 11 1358003.502 423240.485 FOUND CAPPED 5/8" IRON ROD "WITNESS CORNER LB 5265"N/A 181+73.23 79.57' LT. TAMPA
DS 12 1357971.288 423342.240 FOUND 1/2" IRON ROD NO IDENTIFICATIONN/A 182+73.67 50.56' LT. TAMPA
DS 1 1358017.100 423992.473 FOUND 5/8" CAPPED IRON ROD ILLEGIBLEN/A 50+82.18 792.00' RT. LAKE
DS 2 1358106.869 423846.205 FOUND 1/2" IRON ROD NO IDENTIFICATIONN/A 51+73.92 646.96' RT. LAKE DS 3 1358141.198 423763.031 FOUND 5/8" IRON ROD NO IDENTIFICATIONN/A 52+09.37 564.26' RT. LAKE
DS 5 1358178.752 423597.471 FOUND 5/8" IRON ROD NO IDENTIFICATIONN/A 52+49.16 399.22' RT. LAKE
DS 7 1358183.593 423499.731 FOUND 5/8" IRON ROD NO IDENTIFICATIONN/A 52+55.32 301.55' RT. LAKE
DS 8 1358180.478 423237.978 FOUND NAIL & DISK NO IDENTIFICATIONN/A 52+55.74 39.78' RT. LAKE
PROP 300 1358180.656 423238.099 FOUND NAIL & DISK NO IDENTIFICATIONN/A 52+55.92 39.91' RT. LAKE
DS 4 1358196.875 423650.118 FOUND NAIL & DISK "LB 6569"N/A 52+66.57 452.11' RT. LAKE
DS 6 1358208.628 423499.506 FOUND NAIL & DISK "RLS 1762"N/A 52+80.36 301.67' RT. LAKE
DS 9 1358229.934 423237.492 FOUND NAIL & DISK "PLS 6845"N/A 53+05.20 39.97' RT. LAKE
DS 10 1358258.932 423157.087 FOUND 5/8" CAPPED IRON ROD "LLOVERAS PLS 1762"N/A 53+35.28 40.04' LT. LAKE
CONC. CURB
CONC.
CURB
C O N C
C U R
BC
O N C
C U R B
C O N C
C U R
B BURIED GAS BURIED CABLE
BURIED GAS
B U R
IE
D C
A B
LE
P.
I.
.1
181180179
SIDEWALK EASEMENT
P.
C .3
EXISTING R/W LINE
EXISTING R/W LINEATMS / PINELLAS COUNTY
W A
TE
R P
IN
EL
LA
S
C O U N
TY
ATMS / PINELLAS COUNTY
TO LOOP
TO LOOP A
TM
S
PI
N
EL
LA
S
C O U N
TY
A
TM
S
PI
N
EL
LA
S
C O U N
TY
TRAFFIC SIGNAL /PINELLAS COUNTY
B U R
IE
D F
IB
ER
O
PT
IC
U
N
IT
I
TRAFFIC SIGNAL /
PINELLAS COUNTY
TR
A
FF
IC
S
IG
N A L
PI
N
EL
LA
S
C O U N
TY
R
EC
LA
IM
ED
W
A
TE
R
PI
N
EL
LA
S
C O U N
TY
Feet 1" = 40'
40200 10
C O N C
C U R B
C O N C
C U R B
C O N C
C U R B C O N C
C U R B
W C O N C
BURIED GAS
BURIED CABLE
182181
SIDEWALK EASEMENT
DRAINAGE AND/OR UTILITY EASEMENT(P)PERPETUAL ROADWAY, DRAINAGE AND UTILITY EASEMENT(D)
P.
C .3
P.
T.
.8
EXISTING R/W LINE
EXISTING R/W LINE
TRAFFIC SIGNAL / PINELLAS COUNTY
COMMUNICATIONS / UNKNOWN
WATER / PINELLAS COUNTY
W A
TE
R P
IN
EL
LA
S
C O U N
TY
TRAFFIC SIGNAL / PINELLAS COUNTY
ATMS / PINELLAS COUNTY
A
TM
S
PI
N
EL
LA
S
C O U N
TY
A
TM
S
PI
N
EL
LA
S
C O U N
TY
TR
A
FF
IC
S
IG
N A L
PI
N
EL
LA
S
C O U N
TY
TRAFFIC SIGNAL /PINELLAS COUNTY
B U R
IE
D F
IB
ER
O
PT
IC
U
N
IT
I
TR
A
FF
IC
S
IG
N A L
PI
N
EL
LA
S
C O U N
TY
R
EC
LA
IM
ED
W
A
TE
R
PI
N
EL
LA
S
C O U N
TY
Feet
CONC. CURB
W/ 2' CONC
B U R
IED
C A B
LE
W/ 2' CONCW/ 2' CONC
1P.I. 4
.9
494847
SID
EW
A
LK
EA
SEM
EN
T
SIDEWALK EASEMENT P.C. 180+95.36
EXISTING R/W LINE
EXISTING R/W LINE
RECLAIMED WATER / PINELLAS COUNTY
WATER / PINELLAS COUNTY
WATER / PINELLAS COUNTY
WATER / PINELLAS COUNTY
A
TM
S / PIN
ELLA
S C O U N
TY
ATMS / PINELLAS COUNTY
ATMS / PINELLAS COUNTY
TRAFFIC SIGNAL /
PINELLAS COUNTY
TR
A
FFIC
SIG
N A L /
PIN
ELLA
S C O U N
TY
BURIED FIBER OPTIC / UNITI
TRAFFIC SIGNAL /
PINELLAS COUNTY
SANITARY FORCE MAIN /
PINELLAS COUNTY
RECLAIMED WATER /
PINELLAS COUNTY
Feet
C O N C C U R B
CONC. CURB
CONC. CURB
C O N C C U R B
B U R
IED
G A S
BURIED GAS
BURIED CABLE
IRRIGATION VALVE
P.I. 53+45.59
535251
DRAINAGE
EASEMENT
EXISTING R/W LINE
EXISTING R/W LINE
EXISTING R/W LINE
BURIED GAS
HANDRAILTRAFFIC SIGNAL / PINELLAS COUNTYA
TM
S / PIN
ELLA
S C O U N
TY
WATER / PINELLAS COUNTY
SANITARY FORCE MAIN / PINELLAS COUNTY
BURIED FIBER OPTIC / UNITI
TR
A
FFIC
SIG
N A L /
PIN
ELLA
S C O U N
TY
RECLAIMED WATER /
PINELLAS COUNTY
Feet
PID 004183F
COUNTYWIDE MAST ARM SIGNAL HARDENING AND
INTERSECTION IMPROVEMENT
WEST LAKE RD AT TAMPA RD
TF-1
TF-2
TF-3
TF-4 - TF-5
TF-6
TF-7
TF-9
TF-10
TF-11 - TF-12
TF-13
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
SHEET DESCRIPTION
KEY SHEET
SIGNATURE SHEET
TABULATION OF QUANTITIES
GENERAL NOTES
SIGNALIZATION PLAN
ROADWAY PLAN
GUIDESIGN WORKSHEET
SPLICING DIAGRAM
BEST MANAGEMENT PRACTICES PLANS & NOTES
MAST ARM TABULATION
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
HNTB CORPORATION
ONE TAMPA CITY CENTER
201 N FRANKLIN ST. SUITE 1200
BENJAMIN S. RODGERS, P.E. NO. 80350
TF-14
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
SHEET DESCRIPTION
REPORT OF CORE BORING
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
MC SQUARED, INC.
GEOTECHNICAL CONSULTANTS
5808-A BRECKENRIDGE PARKWAY
TAMPA, FL 33610
JORDAN FOX, P.E. NO. 87472
TF-15 - TF-20
THE ABOVE NAMED PROFESSIONAL SURVEYOR AND MAPPER SHALL BE RESPONSIBLE
FOR THE FOLLOWING SHEETS IN ACCORDANCE WITH RULE 5J-17.062, F.A.C.
SHEET DESCRIPTION
LAND SURVEYOR REPORT
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
ECHEZABAL & ASSOCIATES, INC. LB 6490
108 W. COUNTRY CLUB DR.
TAMPA, FL 33612
STEPHEN M. TATE, P.S.M. 5242
P R O
FESSIONAL EN
GIN
EE
R
L I C E N S E
F L O R I D A
BE
NJ
AM
IN S. RODGERS
P R O
FESSIONAL EN
GIN
EE
R
L I C E N S E
F L O R I D A
JOR
DAN FOX
P R O
FESSIONAL SURV
EY
O R
L I C E N S E
F L O R I D A
ST
EPH
EN M. TATE
STATE OF
P R O
FESSIONAL ENGIN
EE
R
L I C E N S E
F L O R I D A
JU
LIA
N GUTIERREZ
No 48879
SHEET NO.
TF-8
THE ABOVE NAMED PROFESSIONAL ENGINEER SHALL BE RESPONSIBLE FOR THE
FOLLOWING SHEETS IN ACCORDANCE WITH RULE 61G15-23.004, F.A.C.
SHEET DESCRIPTION
STANDARD MAST ARM ASSEMBLIES DATA TABLE
THIS ITEM HAS BEEN DIGITALLY
SIGNED AND SEALED BY
ON THE DATE ADJACENT TO THE SEAL
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
HNTB CORPORATION
ONE TAMPA CITY CENTER
201 N FRANKLIN ST. SUITE 1200
JULIAN GUTIERREZ, P.E. NO. 48879
TABULATION OF QUANTITIES
PAY
ITEM NO.
REF.
SHEET
FINALPLANFINAL PLANFINALPLAN FINALPLAN
DESCRIPTION
SHEET NUMBERS
UNIT
FINALPLANFINAL PLANFINALPLANPLAN FINALPLAN PLANFINAL
GRAND
TOTAL
TOTAL
THIS
SHEETTF-6
TF-7
GOVERNING SPECIFICATIONS AND STANDARDS:
1. FLORIDA DEPARTMENT OF TRANSPORTATION DIVISION II AND III OF "STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION", (JANUARY 2022) AND ALL SUPPLEMENTAL SPECIFICATIONS THERETO. STANDARD SPECIFICATIONS ARE AVAILABLE AT THE FOLLOWING WEBSITE: HTTP://WWW.FDOT.GOV/PROGRAMMANAGEMENT/IMPLEMENTED/SPECBOOKS
2. FLORIDA DEPARTMENT OF TRANSPORTATION FY (2022-2023) STANDARD PLANS FOR ROAD AND BRIDGE CONSTRUCTION AND APPLICABLE INTERIM REVISIONS (IRs). STANDARD PLANS FOR ROAD CONSTRUCTION AND IRs ARE AVAILABLE AT THE FOLLOWING WEBSITE: HTTP://WWW.FDOT.GOV/DESIGN/STANDARDPLANS. COMPLIANCE WITH ALL APPLICABLE INDICES IS
REQUIRED.
3. STATE OF FLORIDA "MANUAL OF UNIFORM MINIMUM STANDARDS FOR DESIGN, CONSTRUCTION AND MAINTENANCE FOR STREETS AND HIGHWAYS", 2018 (FLORIDA GREENBOOK) HTTP://WWW.FDOT.GOV/ROADWAY/FLORIDAGREENBOOK/FGB.SHTM
4. PINELLAS COUNTY "STANDARD TECHNICAL SPECIFICATIONS FOR UTILITIES & RELATED CONSTRUCTION" JANUARY 2022
AVAILABLE ON-LINE:HTTP://WWW.PINELLASCOUNTY.ORG/TECHNICAL/
5. PINELLAS COUNTY "STANDARD ENGINEERING DETAILS" JUNE 2022 AVAILABLE ON-LINE:
HTTP://WWW.PINELLASCOUNTY.ORG/TECHNICAL/
6. PINELLAS COUNTY "TRAFFIC OPERATIONS SIGNAL STANDARDS" 2017.1 EDITION AVAILABLE BY REQUEST WHEN FDOT AND PINELLAS COUNTY SPECIFICATIONS DIFFER, PINELLAS COUNTY SPECIFICATIONS SHALL TAKE PRECEDENCE IF PINELLAS
COUNTY'S IS MORE STRINGENT AS DETERMINED BY THE ENGINEER.
7. PINELLAS COUNTY SUPPLEMENTAL SPECIFICATIONS FOR ROADWAY AND GENERAL CONSTRUCTION, APRIL 2022.
8. WHEN FDOT AND PINELLAS COUNTY SPECIFICATIONS DIFFER, PINELLAS COUNTY SPECIFICATIONS SHALL TAKE
PRECEDENCE IF PINELLAS COUNTY'S IS MORE STRINGENT AS DETERMINED BY THE ENGINEER.
NOTIFICATIONS:
1. CONTACT PINELLAS COUNTY TRAFFIC ENGINEERING, (727-464-8922) PRIOR TO THE BEGINNING OF WORK TO CHECK
FOR UPDATES TO STANDARDS OR OTHER INFORMATION.
2. ONE WEEK PRIOR TO THE BEGINNING OF WORK, NOTIFY:
MR. JOHN LEMONIAS, PINELLAS COUNTY
22211 US 19 NORTH CLEARWATER, FL 33765
PHONE: (727) 420-6270
MR. VINCE HARPER, PINELLAS COUNTY
22211 US HIGHWAY 19 NORTH
CLEARWATER, FL 33765
PHONE: (727) 410-6301
MR. WAYNE DEMPSEY
FDOT DISTRICT SEVEN TRAFFIC OPERATIONS
CONSTRUCTION LIAISON
FLORIDA DEPARTMENT OF TRANSPORTATION
11201 NORTH McKINLEY DRIVE
TAMPA, FLORIDA 33612
PHONE (813) 975-6226
3. GIVE THE ENGINEER A MINIMUM OF TWO FULL BUSINESS DAYS NOTICE PRIOR TO FOUNDATION EXCAVATION FOR
MAST ARMS FOR FINAL LOCATION APPROVAL.
4. OBTAIN LOCAL PERMITS TO WORK OUTSIDE THE FDOT AND COUNTY RIGHT OF WAY ON LOCAL STREETS.
WORK SUPERVISION:
1. AN I.M.S.A. CERTIFIED LEVEL II (ELECTRONICS OR ELECTRICAL) TECHNICIAN ON THE JOB SITE AT ALL TIMES WHEN
WORKING WITHIN THE TRAFFIC SIGNAL CONTROLLER CABINET, SIGNAL POLES OR MAST ARM ASSEMBLIES.
2. RESPOND TO CALLS TWENTY-FOUR HOURS A DAY, SEVEN DAYS A WEEK. WITHIN THREE HOURS OF NOTIFICATION OR
DOCUMENTED ATTEMPTED NOTIFICATION, THE CONTRACTOR SHALL BE ON-SITE MAKING NEEDED REPAIRS OR MODIFICATIONS. FAILURE TO MEET THE TIME REQUIREMENTS GIVES THE COUNTY, AT THEIR DISCRETION, THE RIGHT TO REQUEST ASSISTANCE FROM LOCAL LAW ENFORCEMENT TO CONTROL TRAFFIC FOR THE PERIOD OF TIME UNTIL THE CONTRACTOR RESPONDS AND MAKES NEEDED REPAIRS. THE COST FOR LAW ENFORCEMENT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. THE COUNTY, AT THEIR DISCRETION, ALSO HAS THE RIGHT TO BRING IN ASSISTANCE TO MAKE NEEDED REPAIRS AND BE REIMBURSED BY THE CONTRACTOR, IF THE CONTRACTOR CANNOT
MEET THE TIME REQUIREMENTS.
3. A SUPERINTENDENT FOR THE PRIME CONTRACTOR IS REQUIRED TO BE ON SITE AT ALL TIMES WHEN WORK IS BEING PERFORMED. ALL WORKERS ON THE JOB SITE WILL BE COURTEOUS TO THE PUBLIC AT ALL TIMES AND SHALL REFER ANY QUESTIONS OR CONCERNS TO THE CONTRACTOR'S SUPERINTENDENT OR THE COUNTY INSPECTOR. THE SUPERINTENDENT SHALL SPEAK AND UNDERSTAND ENGLISH AND SHALL BE AVAILABLE AT ALL TIMES FOR TIMELY RESOLUTION OF PROJECT RELATED ISSUES. PROVIDE A 24 HOUR EMERGENCY PHONE NUMBER TO THE COUNTY INSPECTOR.
TRAFFIC CONTROL/EQUIPMENT:
1. DURING CONSTRUCTION ALL EXISTING SIGNALIZATION SHALL REMAIN IN PLACE, INCLUDING VEHICLE ACTUATION AND
PEDESTRIAN SIGNAL OPERATION. ALL ACTUATED PHASES SHALL BE MAINTAINED DURING THE PROJECT, INCLUDING WHEN LOOPS OR OTHER DETECTION DEVICES ARE DAMAGED. THE USE OF MICROWAVE DETECTORS OR THE INSTALLATION OF NEW LOOPS WITHIN 48 HOURS OF DAMAGE SHALL BE MADE FOR FULL DETECTOR ACTUATION UNTIL THE PROPOSED VIDEO
DETECTION IS ACTIVATED.
2. UNLESS OTHERWISE NOTED, ALL REMOVED AND SURPLUS EQUIPMENT SHALL BE DELIVERED TO THE PINELLAS COUNTY TRAFFIC SIGNAL SHOP, BETWEEN 6:30 AM AND 4:30 PM MONDAY THRU THURSDAY, LOCATED AT 22211 US 19 NORTH, CLEARWATER, FL 33765. PROVIDE A MINIMUM FORTY-EIGHT HOURS NOTICE PRIOR TO DELIVERY. THE CONTACT PHONE
NUMBER IS (727) 464-8922.
3. THROUGHOUT THE ENTIRE PROJECT, MAINTAIN COMMUNICATIONS BETWEEN THE COMPUTERIZED SIGNAL SYSTEM, THE INTERSECTION AND ADJACENT INTERSECTIONS (WHERE APPLICABLE) VIA INTERCONNECT CABLE AND BE RESPONSIBLE FOR ANY ADDITIONAL COST RELATED TO MAINTAIN THE COMMUNICATIONS. CONTACT PINELLAS COUNTY TRAFFIC ENGINEERING ONE WEEK PRIOR TO ANY WORK WHICH MAY CAUSE DISRUPTION OF COMMUNICATIONS.
FIELD VERIFICATION AND ADJUSTMENTS:
1. ADJUST EQUIPMENT OR COMMUNICATION INFRASTRUCTURE FROM LOCATIONS SHOWN ON THE PLANS WHEN NECESSARY
DUE TO FIELD CONDITIONS AFTER APPROVAL FROM THE ENGINEER. ANY DEVIATIONS FROM THE CONSTRUCTION
DOCUMENTS SHALL BE RECORDED ON THE AS-BUILT PLANS AND TABULATION SHEETS.
GENERAL CONSTRUCTION:
1. RETURN ALL DISTURBED AREAS TO PRECONSTRUCTION CONDITIONS WITHIN 72 HOURS OF THE CONSTRUCTION ACTIVITY.
THIS INCLUDES RESTORATION OF GRADE AND SODDING FOR STABILIZATION AND WATERING OF THE SOD UNTIL IT HAS
TAKEN ROOT.
2. ALL REFERENCES IN THE PLANS TO RIGID CONDUIT SHALL BE INSTALLED AS RIGID GALVANIZED STEEL CONDUIT (RGSC).
ALL HARDWARE REQUIRED TO OFFSET THE RIGID CONDUIT FROM EXISTING INFRASTRUCTURE SHALL BE OF SIMILAR
MATERIALS TO PREVENT CATHODIC REACTIONS.
TRAFFIC CONTROL PLAN NOTES:
1. MAINTAIN TRAFFIC ON THE EXISTING ROADWAY BY USE OF THE FDOT FY 2022-23 STANDARD PLANS FOR ROAD AND BRIDGE CONSTRUCTION, INDEX NUMBERS 102-600 THROUGH 102-670 AS APPROPRIATE FOR THE WORK BEING
PERFORMED
2. DURING NON-WORKING HOURS NO EQUIPMENT, VEHICLES OR MATERIALS SHALL BE PARKED OR STORED WITHIN THE
CLEAR ZONE OF ANY ROADWAY.
3. REGULATORY SPEEDS SHALL BE THE SAME AS THE EXISTING POSTED SPEEDS THROUGH THE PROJECT LIMITS.
4. GROUND MOUNTED SIGNS MAY BE USED IN LIEU OF POST MOUNTED SIGNS ONLY IF CONSTRUCTION OPERATION WILL NOT EXCEED A 12-HOUR PERIOD. SIGNS ARE TO BE IN ACCORDANCE WITH THE FDOT STANDARD PLANS INDEX 102-600
SERIES AND AS SPECIFIED IN THE MUTCD.
5. A LANE CLOSURE SHALL BE REQUIRED WHENEVER A BOOM ARM OR BUCKET CROSSES A TRAVEL LANE. THIS ALSO APPLIES TO INSTALLING STRUCTURE COMPONENTS AND EQUIPMENT OVER THE TRAVEL LANES. ALL WORK REQUIRING A LANE CLOSURE SHALL BE DONE BETWEEN 10:00 PM AND 6:00 AM. THIS TIME FRAME MAY BE FURTHER LIMITED BY
SPECIAL EVENTS OR HOLIDAYS AS OUTLINED IN THE SPECIFICATIONS.
A. THE CONTRACTOR SHALL, AT THE DISCRETION OF THE ENGINEER, OPEN ANY TEMPORARY LANE CLOSURE CAUSING EXTENDED TRAFFIC CONGESTION (5-MINUTE DELAY) UNTIL TRAFFIC HAS RETURNED TO AN ACCEPTABLE FLOW AS
DETERMINED BY THE ENGINEER.
B. THE CONTRACTOR SHALL NOTIFY THE ENGINEER A MINIMUM OF 48-HOURS IN ADVANCE OF ANY LANE CLOSURES.
C. DURING PERIODS OF LANE CLOSURES THE CONTRACTOR SHALL PROVIDE DEDICATED CREW FOR THE INSTALLATION, MAINTENANCE AND REMOVAL OF THE TRAFFIC CONTROL DEVICES, BARRICADES, SIGNS, ARROW BOARDS, ETC. THIS CREW SHALL CONSIST OF AT LEAST THREE MEMBERS OF THE CONTRACTOR'S WORK FORCE WHOSE SOLE RESPONSIBILITY SHALL BE THE MAINTENANCE OF TRAFFIC CONTROL. THE CONTRACTOR SHALL FURNISH A WORK
VEHICLE TO AID IN MAINTAINING THE CONTROL DEVICES.
D. THE CONTRACTOR SHALL BE REQUIRED TO SUBMIT A WRITTEN PLAN WHICH DETAILS EACH ACTIVITY INVOLVED IN THE LANE CLOSURE. THE PLAN SHALL INCLUDE BACK-UP PLANS FOR ACTIVITIES CRITICAL TO RE-OPENING THE LANES TO TRAFFIC. THE BACK-UP PLAN SHALL INCLUDE THE ACTIVITIES OF ALL SUBCONTRACTOR'S OPERATIONS AS WELL AS THE PRIME CONTRACTOR'S. NO LANE CLOSURE WILL BE ALLOWED WITHOUT A PLAN TO ACHIEVE RE-OPENING.
E. LANE CLOSURES SHALL NOT BE PERFORMED DURING HOLIDAY PERIODS AS LISTED IN THE SPECIFICATIONS AND WEDNESDAY NIGHT PRIOR TO THANKSGIVING DAY.
This is the start of the file's text. The full file is on GovTribe.