Final Drawings - 553-25-500.pdf

PDF 157 KB Posted

Attached to
Z1DA--Lower Level Pharmacy Flooring Replacement IFB 553-25-500
Solicitation number
36C25025B0023
Issued by

About this file

The document is a detailed floor plan drawing for a pharmacy renovation project at a Veterans Affairs (VA) facility. The drawing shows the lower level pharmacy area (LL101, LL101A, LL102, LL102A, LL102B) marked for construction, with specific zones including clean rooms, hazardous and non-hazardous buffer areas, controlled drug storage, and pharmacy cages. The drawing includes a comprehensive list of construction activities such as removing existing floor-mounted equipment, relocating supplies, installing new flooring, preparing floors, patching and painting walls, and conducting terminal cleaning. The proposed construction area covers multiple interconnected rooms totaling approximately 145 square feet, with a temporary construction barrier delineating the work zone.

The drawing is associated with VA Veterans Health Administration Solicitation Number 36C25025B0023, specifically for a "Z1DA--Lower Level Pharmacy Flooring Replacement IFB 553-25-500" project. The detailed drawing provides precise instructions for contractors, including specific removal and installation tasks, flooring preparation requirements, and notes about reinstalling equipment and conducting necessary site modifications. Drawing notes outline a step-by-step process for contractors, including removing existing wall-mounted items, preparing floors, installing new epoxy flooring, and conducting final cleaning and equipment repositioning.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OFFICE

LL182

OFFICE

LL183

OFFICE

LL184

CONTROLED

DRUGS

LL104

H.A.C.

LL103

NON-HAZARDOUS

BUFFER

AREA

LL101A

HAZARDOUS

BUFFER

AREA

LL102A

ANTE

LL102

CLEAN

ROOM

LL101

STORAGE

LL106

PHARMACY

LL109

PHARMACY

LL100

PHARMACY

LL100A

PHARMACY

CAGE

LL109A

AREA OF CONSTRUCTION

HAC

LL102B

LL101, LL101A, LL102, LL102A, LL102B

TEMPORARY CONSTRUCTION BARRIER

NO SCALE

145 S.F.

127 S.F.

43 S.F. 426 S.F.

26 S.F.

DRAWING NOTES:

TR

AN

SI

TI

O

N S

TR

IP

AutoCAD SHX Text

BENCH

AutoCAD SHX Text

HOOD

AutoCAD SHX Text

HOOD

AutoCAD SHX Text

HOOD

AutoCAD SHX Text

HOOD

AutoCAD SHX Text

1. REMOVE EXISTING FLOOR MOUNTED REMOVE EXISTING FLOOR MOUNTED ITEMS. TO BE REINSTALLED. 2. REMOVE EXISTING WALL MOUNTED REMOVE EXISTING WALL MOUNTED ITEMS. TO BE REINSTALLED. 3. REMOVE EXISTING HOODS AND STORE REMOVE EXISTING HOODS AND STORE AS DIRECTED BY COR. 4. REMOVE EXISTING FLOORING AND REMOVE EXISTING FLOORING AND INTEGRATED COVE BASE. 5. SCARIFY FLOOR AND PREP FLOOR SCARIFY FLOOR AND PREP FLOOR FOR NEW FLOORING PER MANUFACTURER'S SPECIFICATIONS. PROVIDE TRANSITION STRIPS AS REQUIRED. 6. INSTALL NEW FLOORING AND 4" HIGH INSTALL NEW FLOORING AND 4" HIGH INTEGRATED COVE BASE. 7. PATCH AND PAINT WALLS AND PATCH AND PAINT WALLS AND CEILINGS WITH EPOXY COATING. MATCH EXISTING. 8. CAULK DOOR FRAMES. CAULK DOOR FRAMES. 9. REINSTALL FLOOR AND WALL REINSTALL FLOOR AND WALL MOUNTED ITEMS. 10. REINSTALL HOODS AND RECERTIFY.REINSTALL HOODS AND RECERTIFY.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RELOCATE SUPPLIES AND MOVABLE EQUIPMENT

AutoCAD SHX Text

GC

AutoCAD SHX Text

VA

AutoCAD SHX Text

RELOCATE PHONE AND COMPUTER

AutoCAD SHX Text

REMOVE WALL MOUNTED ITEMS

AutoCAD SHX Text

REMOVE FLOOR MOUNTED ITEMS

AutoCAD SHX Text

REMOVE IV HOODS AND STORE

AutoCAD SHX Text

INSTALL ICRA BARRIERS AND WALK OFF MATS

AutoCAD SHX Text

INSTALL NEGATIVE AIR MACHINE

AutoCAD SHX Text

REMOVE EXISTING FLOORING AND INTEGRATED COVE BASE

AutoCAD SHX Text

PREP FLOOR FOR NEW RESINOUS EPOXY FLOOR

AutoCAD SHX Text

INSTALL NEW FLOOR AND INTEGRATED COVE BASE

AutoCAD SHX Text

PATCH AND PAINT WALLS

AutoCAD SHX Text

REINSTALL WALL MOUNTED ITEMS

AutoCAD SHX Text

REINSTALL FLOOR MOUNTED ITEMS

AutoCAD SHX Text

ACTIVITY:

AutoCAD SHX Text

REINSTALL HOODS AND RECERTIFY

AutoCAD SHX Text

THOROUGH CLEANING

AutoCAD SHX Text

TERMINAL CLEANING

AutoCAD SHX Text

MOVE SUPPLIES AND EQUIPMENT BACK IN

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text NOTE: REMOVE EXISTING DOOR SILLS, TO BE REINSTALLED AFTER NEW FLOORING INSTALL. (TYP.)

Sheets and Views
Model

File details come from the government source that posted it. Updated .