Example_of_a_Call_02.pdf

PDF 248 KB Posted

Attached to
IDIQ Roofing Repair and Replace Federal contract opportunity
Solicitation number
FA8601-14-R-0060
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

EXAMPLE ONLY OF A CALL SHEET THAT COULD BE ISSUED FROM THE RESULTING CONTRACT OF THIS SOLICITATION Call Sheet 2.

View the file

Other files for this federal contract opportunity

Other files attached to IDIQ Roofing Repair and Replace, newest first.
File Type Posted
Combined_RFI.pdf PDF
FA8601-15-R-0003_Amendment_2.doc.pdf PDF
Specifications_Roofing_12Nov14.pdf PDF
Example_of_a_Call_03.pdf PDF
Example_of_a_Call_01.pdf PDF
Example_of_a_call_04.pdf PDF
Amend_1.pdf PDF
Attach_1_Specification_Roofing.pdf PDF
FA8601-15-R-0003.pdf PDF
Attach_2_Bid_Schedule.xlsx XLSX spreadsheet
Attach_3_General_Decision.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 1

DELIVERY ORDER CALL INFORMATION (ROOFING)

Delivery Order: #0005 Project: ZHTVXXXX

Contract: XXXXXXXX

Work Req: ZHTVAXXXX

Total Est Cost of Call: $

Date of Call: (yyyymmdd) EEIC 521: $0.00

Req Start Date: (yyyymmdd) EEIC 524: $XXXXX

Req Completion Date: (yyyymmdd) EEIC 523: $0.00

Effective Date: (yyyymmdd) EEIC 529: $0.00

Revised Date: Total Cost: $XXXXX

Work Location: FACILITY: XXXXX Section “D”

Work Description: FACILITY: XXXXX (Sec. “D”) total roof replacement.

PROJECT: #XXXXX XXXXXX EEIC: 524

PERIOD OF PERFORMANCE IS: 30 DAYS

ITEM DESCRIPTION PER AMOUNT

0001AD

DEMO STANDARD NONASBESTOS MULTI-PLY BUR W/

GRAVEL SF 7000

0001AF DEMO STAND NONASB MULTI PLY PERIMETER FLASHING LF 620

0001AL DEMO ROOF INSULATION UP TO 4" THK SF 7000

0001AU VACUUM NON-EMBEDDED GRAVEL SF 7000

0001AO DEMO OF ASPHALTIC FILL CF 2000

0001BT DEMO OR RAISE HEAVY ROOF EQUIPMENT EA 4

0003AL POLYURETHANE SEALANT 1/2"X 3/8" LF 1200

0004AE PLYWOOD DECKING, 3/4" CDX, T&G SF 320

0005AF 1.5" ISOCYANURATE BOARD, HOT APPLIED SF 7000

0005AH 2.0" ISOCYANURATE BOARD, HOT APPLIED SF 7000

0005AJ

TAPERED ISOCYANURATE BOARD VARIOUS THICKNESSES

HOT APP. SF 7000

0005AT 3/4" PERLITE BOARD, HOT APPLIED SF 7000

0005BT TAPERED PERLITE, 1/4"/FT INCL. FILLER SF 1000

0005BW MINERAL FIBER CANT STRIP, 1-1/2" X 5" FACE LF 650

0007AG FIBERGLASS BASE SHEET, HOT APPLIED, 1-PLY SF 7000

0007AN BUR, TYPE VI FIBERGLASS, 4-PLY, ASPHALT SF 7000

0008AB ASPHALT PRIMER SF 7000

0008AE ASPHALT FLOOD COAT AND GRAVEL SURFACE SF 7000

0008AM FIBERED ASPHALT MASTIC, ROWEL GRD W/GLASS FABRIC SF 300

0009AE

1-PLY SBS MOD BITUMEN SHT GRAN SURFACE, 8"-

16"HIGH SF 1050

0009AL 30X30"LEAD ROOF DRAIN FLASHING AT EXIST.ROOF DRAIN EA 2

0009AP LEAD PLUMBING STACK FLASHING AT EXISTING STACK INC EA 1

0010AX REATTACH GUTTERS OR DOWNSPOUTS LF 950

0010AZ

RMV GUTTERS/DWNSPTS/MTL COUNTER FLSHNG/DRP

EDGE/GRV LF 1250

0010BB PREFIN SHT METAL COUNTER FLASHING, 6-8" WIDE LF 700

0010BH EMBEDDED PREFIN SHT MTL ROOF EDGE/GRAVEL STOP,6-8" LF 50

0010BT PREFIN SHT MTL COPING CAP 16-48" GIRTH W/ CONT CLT SF 1100

0010CF MISC. PREFINISHED SHT MTL TRIM, 24 GA SF 100

ATTACHMENT 1

0011AM NEW RING CLAMP AND BOLTS ON EXISTING C.I. ROOF DRN EA 2

0011AZ ROOF WALK TREADS, 3'X4' EA 10

0011BG DISCONNECT, RECONNECT, ELECTRIC AT MECH UNIT EA 4

0011BH FLUSH OUT ROOF DRAINS AND STORM PIPING HR 4

0014AR REMOVE AND RE-INSTALL LIGHTNING PROTECTION EA 2

0014AT SCAFFOLDING, STEEL TUBE (approx. 2500SF) EA 1

0014AW 80 FOOT BOOM LIFT RENTAL (ITEM # 11.1.37) DAY 4

TOTAL $XXXXXXXX

File details come from the government source that posted it. Updated .