Example_of_a_Call_01.pdf

PDF 105 KB Posted

Attached to
IDIQ Roofing Repair and Replace Federal contract opportunity
Solicitation number
FA8601-14-R-0060
Issued by
Department of the Air Force Materiel Command Lifecycle Management Center Wright Patterson Air Force Base

About this file

EXAMPLE ONLY OF A CALL SHEET THAT COULD BE ISSUED FROM THE RESULTING CONTRACT OF THIS SOLICITATION Call Sheet 1.

View the file

Other files for this federal contract opportunity

Other files attached to IDIQ Roofing Repair and Replace, newest first.
File Type Posted
Combined_RFI.pdf PDF
FA8601-15-R-0003_Amendment_2.doc.pdf PDF
Specifications_Roofing_12Nov14.pdf PDF
Example_of_a_Call_02.pdf PDF
Example_of_a_Call_03.pdf PDF
Example_of_a_call_04.pdf PDF
Amend_1.pdf PDF
FA8601-15-R-0003.pdf PDF
Attach_2_Bid_Schedule.xlsx XLSX spreadsheet
Attach_1_Specification_Roofing.pdf PDF
Attach_3_General_Decision.pdf PDF
Show all 11

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Task Order Call Information

Work Location : FACILITY XXXXXX

Work Description : Total roof Replacement and new metal coping

PERFORMANCE PERIOD 30 DAYS

Project : XXXXXX Roofing Repair/Replacement Contract : XXXXX

Work Request : ZHTVXXXXX

Delivery Order : Call Number : 0001

A. Work Location : West Ramp

FACILITY XXXXXX

B. Work Description : Total roof replacement and new metal coping

PERFORMANCE PERIOD 30 DAYS

C. Summary of Work Quantities :

Bid

Item Description Quantity

0001AD DEMO STANDARD NONASBESTOS MULTI-PLY BUR W/ GRAVEL SF 2400

0001AF DEMO STAND NONASB MULTI PLY PERIMETER FLASHING LF 200

0001AL DEMO ROOF INSULATION UP TO 4" THK SF 2400

0001AU VACUUM NON-EMBEDDED GRAVEL SF 2400

0001BQ DEMO OR RAISE LIGHTWEIGHT ROOF EQUIPMENT EA 1

0003AL POLYURETHANE SEALANT 1/2"X 3/8" LF 220

0005AF 1.5" ISOCYANURATE BOARD, HOT APPLIED SF 2400

0005AP 2.0" ISOCYANURATE BOARD, MECH. FASTENED SF 2400

0005AT 3/4" PERLITE BOARD, HOT APPLIED SF 2400

0005AI TAPERED ISOCYANURATE BOARD, VARIOUS THICKNESS, HOT APP. SF 600

0005BW MINERAL FIBER CANT STRIP, 1-1/2" X 5" FACE LF 220

0007AG FIBERGLASS BASE SHEET, HOT APPLIED, 1-PLY SF 2400

0007AR BUR, 2-PLY TYPE VI, SBS GRANULATED CAP SF 2400

0008AL FIBERED ASPHALT MASTIC, TROWEL GRADE W/GLASS FAB SF 50

0009AE 1-PLY SBS MOD BITUMEN SHT GRAN SURFACE, 8"-16"HIGH SF 300

0009AK EPDM RUBBER W/O TERM BAR, 8"-16" HIGH SF 200

0009AL 30X30"LEAD ROOF DRAIN FLASHING AT EXIST.ROOF DRAIN EA 2

0009AW ALUMINUM TERMINATION BAR, .10"X1.35" LF 120

0010AZ RMV GUTTERS/DWNSPTS/MTL COUNTER FLSHNG/DRP EDGE/GRV LF 400

0010BB PREFIN SHT METAL COUNTER FLASHING, 6-8" WIDE LF 120

0010BT PREFIN SHT MTL COPING CAP 16-48" GIRTH W/ CONT CLT SF 400

0011AM NEW RING CLAMP AND BOLTS ON EXISTING C.I. ROOF DRN EA 2

0012AJ MANUFACTURER'S 20YR NDL BUR/EPDM WARRANTY SQ 24

File details come from the government source that posted it. Updated .