QUESTIONS AND ANSWERS FA8224-12-R-0016 3.docx
DOCX document 13 KB Posted
- Attached to
- C-17 SHOCK STRUT TEST STAND
- Solicitation number
- FA8224-12-R-0016
View the file
Other files
| File | Type | Posted |
|---|---|---|
| QUESTIONS AND ANSWERS 7 FA8224-12-R-0016.docx | DOCX document | |
| QUESTIONS AND ANSWERS 6 FA8224-12-R-0016.docx | DOCX document | |
| HILLAFBI91-302.pdf | ||
| Questions and Answers 4.docx | DOCX document | |
| Questions and Answers 5.docx | DOCX document | |
| QUESTIONS AND ANSWERS 2 FA8224-12-R-0016.docx | DOCX document | |
| QUESTIONS AND ANSWERS FA8224-12-R-0016.docx | DOCX document | |
| FA8224-12-R-0016-0002.doc | DOC document | |
| FA8224-12-R-0016-0001.doc | DOC document | |
| PURCHASE SPECS C-17 SHOCK STRUT TEST STAND.pdf | ||
| FA8224-12-R-0016.doc | DOC document | |
| PURCHASE SPECS C-17 SHOCK STRUT TEST STAND.pdf |
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SOLICITATION FA8224-12-R-0016
QUESTIONS AND ANSWERS #3
1. Appendix A, part B (1) refers to MIL-L-8552C, which in parts 3.4.1, 3.4.2.1, and 3.4.3 (c) requires the Drawings or Report shall contain design data including "the total air volume and isothermal pressure in the extended and fully compresses positions..." Section 4.9.7 h. and Appendix A section 2.C (1) g. and h. describe the test with the strut filled with 200 psig nitrogen at the extended position, and then compressed (cycled 6 times).
What is the remaining internal volume of nitrogen when the strut is in the fully compressed position? Or alternatively what is the compression ratio?
Answer:
4.9.7 Horizontal cycle pressure test
The following are the volumes of the nitrogen with cylinder at full extension and 17.5" stroke.
Full extended volume...... cylinder bore dia. 10.624", cylinder height 22.155" .....1,963.98 cubic in
17.5" stroke (From full extended).... cylinder bore dia. 10.624, cylinder height 4.625"....409.99 cubic in
Note: Cycle stroke cannot be at full extension or compression(sec 4.9.7 h.) and (Figure 4.9.1.C) Make height adjustment of volume calculations according to where the strut cycle will start and end.
****NOTE: Any further questions should be submitted no later than Dec 27, 2011 3:00pm MST for a timely response before the closing date of this Solicitation.*******