Text version
QUESTIONS AND ANSWERS #4
SOLICITATION FA8224-12-R-0016
1. Question: Para a. describes that all surfaces to be painted shall be cleaned and painted per manufacturer’s standard commercial practice, but then para b states that all surfaces to painted must be powder coated. Powder coating is not our standard commercial practice and it would not make sense to paint AND powder coat.
Answer: 4.8 para b is not a requirement and will be removed from the statement of work.
File details come from the government source that posted it. Updated .