Att5_100209_Drawings_Rev1.pdf
PDF 2 MB Posted
- Solicitation number
- FA813727R0003
About this file
This document is a set of construction drawings and design specifications for a federal construction project at Tinker Air Force Base in Oklahoma. The project, identified as WWYK100209, involves the repair of Perimeter Drive and Industrial Boulevard at the base. The design is at the 35% completion stage as of August 6, 2026, with an amendment issued on November 9, 2026. The project is managed by the Air Force Materiel Command's 72nd Air Base Wing Civil Engineer Directorate.
The scope of work includes full-depth pavement repairs to Industrial Boulevard in multiple sections, demolition and installation of new pavement on Perimeter Drive, and new pavement markings including 4-inch dashed white lines and 4-inch solid double yellow lines with breaks at designated entrances. The drawings specify materials and construction standards conforming to Oklahoma Department of Transportation specifications, including 6-inch asphalt concrete pavement with appropriate base layers, stabilized aggregate base, and modified subgrade compacted to specified densities. Contractors are responsible for all construction fencing, barricades, haul routes (with designated truck gates and future routes identified on the base vicinity map), site restoration, and compliance with existing utility locations shown on the site plans. Details provided include standard pavement sections, drainage requirements, silt fence specifications, storm sewer inlet modifications, and concrete drainage flume details. All work is new unless specifically noted as existing or performed by others.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TAXIWAY A
TAXIWAY J
TAXIWAY A
Soldier Creek
So ld ie r C re ek
"A " A ve
"B " A ve
W es t D r.
In du st ria l B lv d.
Perimeter Rd.
Entrance Road "C"
6th St.
1st St.
PROJECT
LOCATION
R U
N W
AY
8/
RUNWAY 13/31
TA
XI
W
AY
G
TAXIW
AY H
TAXIWAY B
TAXIWAY C
TAXIWAY M
TA
XI
W
AY
K
TAXIWAY E
TAXIWAY A
TA
XIW
AY E
E
TAXIWAY F
TAXIWAY D
TAXIWAY E
TAXIWAY J
TA
XI
W
AY
G
TAXIWAY A
TAXIW
AY H
TAXIWAY C
TAXIWAY D
TAXIWAY EE
TAXIWAY F
Elm C reek
Crutcho Creek
Kuhlman Creek
Soldier Creek
Kuhlman Creek
Elm C reek
East Crutcho Creek
Elm Creek
El m
C re ek
Elm Creek
Elm C reek
Elm CreekElm C reek
Ku hlm an C re ek
Ea st
C ru tc ho
C re ek
Elm C ree k
West Crutcho Creek
W es t C ru tc ho
C re ek
Elm Creek
Soldier Creek
Elm C reek
Soldier CreekSoldier Creek
Ea st
C ru tc ho
C re ek
Elm Creek
Ea st
C ru tc ho
C re ek
East C rutcho C reek
Soldier Creek
So ld ie r C re ek
East C rutch o Creek
Soldier C reek
Soldier C reek
So ld ie r C re ek
East Crutcho Creek
416506
21222121
59475946
11401128
62540
61089
838837
62509
62528
62523
62501X
43774
62512
62516
62525
3592135916
99999
62543
32101
71086
53902
50414
55300
56601
930G
948-E
911-E
948-W
61019
911-W
33001
35913
62501
65672
930S
45134
43609
42116
62517
62515
62526
62527
62503
62513
61289
62542
62501OK
11289
62501
15930
15908
15904
15904
15908
15908
15904
15904
15908
62502
41046
62501
62514
62501
61018
71089
45134
96022
43120
41157
44045
45815
40592
43610
62522
41163
15930
15930
11824
Arnold St.
Ea st
D r.
SE 74th St
SE 59th St.
Ai r D ep ot
Patrol Rd.
St af f D r.
Reserve Rd.
5th Ave
"A " A ve
M un iti on s R d.
W ar eh ou se R d.
"B " A ve
7th St.
"H " A ve
M cN ar ne y Av e.
Mitchell Ave
Al er t R d.
Co ok
A ve
W es t D r.
"E "A ve
Extender Dr.
Sentry Rd.
34th St.
Twining Dr.
5th Ave.
Jo ne s
Globemaster Dr.
To w er R d.
Vanaman Rd.
In du st ria l B lv d.
So ut h St
1st St.
Do ol itt le
A ve
Pi cn ic R d.
Ja m es D r.
W ol fe D r.
Ai r D ep ot
Ai r D ep ot
"D " A ve
Perimeter Rd.
Rapcon Rd.
Reserve Rd
"L " A ve
Mercury Rd.
1st St.
Br ow n Dr
Po nd
R d.
O ld
A ir
De po t
Airey Dr.
Bradley Dr.
Entrance Road "C"
Entrance Road "A"
"C " A ve
"C " A ve
Vandenberg Dr.
Hi llt op R d.
Do rm ito ry
R d.
Dormitory Rd.
"M " A ve
Chennault Dr.
M itc he ll A ve
Spaatz Dr.
Co m m od ity D r.
Doolittle Ave
W hi te D r.
3rd Ave.
"D " D riv e
Ba ll
Pa rk
R d.
Joint STARS Dr.
Ai r D ep ot
B lv d
Turbine Dr. Turbine Dr.
Central Plant Dr.
6th St.6th St.
Falco n Dr.
Blackb ird
Dr.
W ey la nd
L oo p
Pegasus Dr.
Thunderbolt D r.
Munitions Rd. Ext.
Codding Rd.
Starlifter Dr.
Chidlaw Ct.
Co rs ai r D r.
Ra pt or Ct
N ig ht H aw k
Ct
Ph an to m
D r.
Fr an kl in
Po w er ho us e
Dr
Sk ym as te r D r.
Spaatz Ct.
La w re nc e
M un de ll
Nabors Dr.
In tr ud er
D r.
M cN ic kl e
M ill er D r.
Ta il
Fe at he r D r.
Holden Dr.
Ai re y C ir.
Smith Ct.
Ra ve n Ct
Air Dep ot Ai r D ep ot
Vanaman Rd.
1st St.
1st St.
TAXIWAY F
Ra w li ng s A ve
Mitc he ll A ve
Mercury Rd.
Ra ily ar d
Rd
He rc ul es
R d.
"F " A ve
Pr op ul sio n Dr
Stratofortress Dr.
96021
Arnold St.
PROJECT
LOCATION
TINKER AFB, OK
VICINITY MAP
BASE
OPERATIONS
B240
CONTRACTING
B3
GOTT
GATE
TINKER GATE
PASS & ID B6611
HRUSKOCY
GATE
EAKER GATE
FIRE DEPARTMENT
B117
VANCE
GATE
LIBERATOR GATE
HOPE
GATE
LEGEND
CONTRACTOR
HAUL ROUTE
LANCER
GATE
TRUCK GATE
PIAZZA GATE
BASE CIVIL
ENGINEER
B400
(FUTURE
HAUL ROUTE)
(F
UT
UR
E
HA
UL
R
OU
TE
FUTURE
TRUCK GATE
FUTURE
HAUL ROUTE
REVIEWED BY:
REVIEWED BY:
USING AGENCY:
ASBESTOS EVALUATION:
SAFETY:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
DATE:
INDUSTRIAL HYGIENE:
DATE:
G-011
SHT.SEQ. SHEET TITLE
CORROSION ENGINEER: (CECE)
CE OPERATIONS: (CECO)
COMMUNICATIONS: (COMM)
CHIEF ENGINEER DIR: (CECE)
CHIEF DESIGN BRANCH: (CECE)
DESIGN MANAGER: (CECE)
ZONE MANAGER:
CONSTRUCTION MANAGEMENT: (CECE)
ENVIRONMENTAL:
BASE CIVIL ENGINEER: (CE)
FIRE DEPARTMENT: (CEFT)
GENERAL
GENERAL NOTES & VICINITY MAP
WWYK100209
REPAIR PERIMETER DR
& INDUSTRIAL BLVD
KEY PLAN:
DISCIPLINE
G-01
GE
NE
RA
L N
OT
ES
AN
D
VI
CI
NI
TY
M
AP
Au g
TE
PA
S R
M
P G
O U
C H
ER
R P
O W
EL
L
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
\P er im et er a nd In du st ria l
W W
YK
RE
PA
IR
P
ER
IM
ET
ER
D R
IN
DU
ST
RI
AL
B
LV
D
35%
DESIGN
TINKER AFB, OK
1 2 3 4 5
E
D
C
B
A
1 2 3 4 5
E
D
C
B
A
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
MA
RK
DA
TE
DE
SC
RI
PT
IO
N
IS
SU
E
DA
TE
DE
SI
GN
G
RO
UP
DE
SI
GN
ED
B Y:
DR
AW
N
BY
CH
EC
KE
D
BY
DE
SI
GN
F
ILE
LO
CA
TI
ON
SHEET
SHEET NUMBER
MA
NA
GE
ME
NT
IN
FO
RM
AT
IO
N
RE
VI
SI
ON
S
PR
OJ
EC
T
IN
FO
RM
AT
IO
N
OF
C-01 CIVIL SYMBOLS AND ABBREVIATIONS2
C-02 PERIMETER DR SITE PLAN W/ UTILITIES
C-03 C-04 C-05 C-06
INDUSTRIAL BLVD SITE PLAN W/ UTILITIES
PERIMETER DR DEMO PLAN (1 OF 2)
PERIMETER DR DEMO PLAN (2 OF 2)
PERIMETER DR INSTALLATION PLAN (1 OF 2)
C-07 PERIMETER DR INSTALLATION PLAN (2 OF 2)
9 C-08 INDUSTRIAL BLVD FULL-DEPTH REPAIRS, SECTION 1
10 C-09 INDUSTRIAL BLVD FULL-DEPTH REPAIRS, SECTION 2
11 C-10 INDUSTRIAL BLVD FULL-DEPTH REPAIRS, SECTION 3
12 C-11 INDUSTRIAL BLVD PAVEMENT MARKING PLAN
13 C-12 PERIMETER DR - ROAD CROSS SECTION
14 DT-01 DETAILS
15 DT-02 DETAILS
14 C-13 CONTOURS AND ELEVATIONS PLAN (1 OF 2)
15 C-14 CONTOURS AND ELEVATIONS PLAN (2 OF 2)
1. BRAND NAMES: REFERENCE TO SPECIFIC BRAND NAMES
OR COMPANIES IS FOR THE PURPOSE OF ESTABLISHING
MINIMUM QUALITY STANDARDS, IDENTIFICATION AND
GUIDANCE AND IS NOT INTENDED TO LIMIT SELECTION OF
OTHER MANUFACTURERS THAT ARE EQUAL OR EXCEED
THE SPECIFIED ITEMS IN TERMS OF PHYSICAL
PROPERTIES, INCLUDING, COLOR RANGE, FINISH,
DURABILITY, APPEARANCE, PERFORMANCE
CHARACTERISTICS, AND OTHER FACTORS. OTHER
PRODUCTS, MATERIALS, COLORS AND SYSTEMS, MAY BE
SUBMITTED FOR EVALUATION AND
APPROVAL/DISAPPROVAL BY THE CONTRACTING OFFICER.
2. THIS SET OF CONSTRUCTION DOCUMENTS SHALL BE
CONSIDERED AS A WHOLE IN THAT THE GENERAL
CONTRACTOR AND ALL THE SUB-CONTRACTORS ARE
RESPONSIBLE FOR THE INFORMATION PRESENTED ON ALL
SHEETS ON THE SET OF DRAWINGS AND ALL SECTIONS OF
THE SPECIFICATIONS.
3. THE CONTRACTOR IS RESPONSIBLE FOR ERECTING ALL
CONSTRUCTION FENCING AND BARRICADES AS REQUIRED
TO PROTECT CONSTRUCTION MATERIAL AND TO PREVENT
ANY UNAUTHORIZED PERSONNEL FROM ENTERING THE
CONSTRUCTION SITE.
4. ANY DAMAGE TO THE EXISTING GROUNDS OR FACILITIES
CAUSED BY CONSTRUCTION TRAFFIC OR ANY
CONSTRUCTION OPERATION SHALL BE REPAIRED OR
REPLACED BY THE CONTRACTOR TO MATCH OR EXCEED
EXISTING CONDITIONS AT NO ADDITIONAL COST TO THE
GOVERNMENT.
5. ALL WORK NOTED & LOCATED IN THESE DOCS SHALL BE
UNDERSTOOD BY THE CONTRACTOR TO REQUIRE ALL NEW
LABOR & MATERIALS UNLESS SPECIFICALLY NOTED TO BE
"EXISTING" OR "BY OTHERS".
GENERAL NOTES:
PROJECT DRAWING INDEX SIGNATURES
NO
V
AM
EN
DM
EN
T
1 C
HA
NG
ES
245'
MATCHLINE
(SEE SHEET C07)
BREAK DOUBLE
YELLOW AT
ENTRANCE
BREAK DOUBLE
YELLOW AT
ENTRANCE
BREAK DOUBLE
YELLOW AT
ENTRANCE
C-11
INDUSTRIAL BLVD PAVEMENT MARKING PLAN
SCALE: NTS
C-11
IN
DU
ST
RI
AL
B
LV
D
PA
VE
ME
NT
MA
RK
IN
G
PL
AN
/1
6/
TE
PA
S R
M
R P
O W
EL
L
T
KI
SE
R
E
SW
EE
N
Y
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
\P er im et er a nd In du st ria l
W W
YK
RE
PA
IR
P
ER
IM
ET
ER
D R
IN
DU
ST
RI
AL
B
LV
D
35%
DESIGN
NEW 4" DASHED WHITE LINE
NEW 4" SOLID DOUBLE YELLOW LINE
TINKER AFB, OK
1 2 3 4 5
E
D
C
B
A
1 2 3 4 5
E
D
C
B
A
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
MA
RK
DA
TE
DE
SC
RI
PT
IO
N
IS
SU
E
DA
TE
DE
SI
GN
G
RO
UP
DE
SI
GN
ED
B Y:
DR
AW
N
BY
CH
EC
KE
D
BY
DE
SI
GN
F
ILE
LO
CA
TI
ON
SHEET
SHEET NUMBER
MA
NA
GE
ME
NT
IN
FO
RM
AT
IO
N
RE
VI
SI
ON
S
PR
OJ
EC
T
IN
FO
RM
AT
IO
N
OF
NO
V
AM
EN
DM
EN
T
1 C
HA
NG
ES
TINKER AFB, OK
TI
N
KE
R
A
IR
F O
R C
E
BA
SE
, O
KL
AH
O M
A
PR
O
JE
C
T
IN
FO
R
M
AT
IO
N
D
ES
IG
N
F
IL
E
LO
C
AT
IO
N
R
EV
IS
IO
N S
M
AR
K
D
ES
IG
N
G R
O U
P:
D R
AW
N
B Y:
C H
EC
KE
D B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E D
ES
C
R
IP
TI
O
N
1 2 3 4 5
E
D
C
B
A
M
AN
AG
EM
EN
T
IN
FO
R M
AT
IO
N
1 2 3 4 5
E
D
C
B
A
IS
SU
E D
AT
E:
SHEET OF
SHEET NUMBER
SH
EE
T
TI
TL
E
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
DT-01
DE
TA
ILS
/1
6/
TE
PA
S R
M
R P
O W
EL
L
T
KI
SE
R
E
SW
EE
N
Y
En gr
\D es ig n\ s\
\2
9\
0_ Su pp or t\0 _3
_D ra w in gs \M od el
\P er im et er a nd In du st ria l
W W
YK
RE
PA
IR
P
ER
IM
ET
ER
D R
IN
DU
ST
RI
AL
B
LV
D
35%
DESIGN
NO
V
AM
EN
DM
EN
T
1 C
HA
NG
ES
6" AC Pavement A-7-2
2" TYPE C AC
6" Stabilized Aggregate Base
4" TYPE A AC
Tack Coat
Prime Coat
1. ALL MATERIALS, EQUIPMENT AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE OKLAHOMA
DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY CONSTRUCTION.
2. AGGREGATE BASE SHALL BE COMPACTED TO 95% MODIFIED PROCTOR DENSITY.
3. THE MODIFIED SUBGRADE SHALL BE COMPACTED TO 95% MODIFIED PROCTOR DENSITY. HAVE A CBR > 8, AND A PI < 14.
4. ALL FILL AND LOOSE MATERIAL BELOW THE 6" MODIFIED SUBGRADE LAYER SHALL BE COMPACTED TO 90 % STANDARD
DENSITY IN LIFTS NO GREATER THAN 6".
6" Modified Subgrade
1. ALL MATERIALS, EQUIPMENT AND CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE
OKLAHOMA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY
CONSTRUCTION.
2. TOOLED OR SAWED JOINTS SHALL BE SPACED WITH THE PCC PAVEMENT JOINTS OR AT 20' IF
PAVEMENT IS AC.
3. EXPANSION JOINTS SHALL BE PLACED EVERY 5th JOINT.
4. EXPANSION JOINTS SHALL BE BRIDGED BY 2 EVENLY SPACED 24" X 1" DIAMETER SMOOTH DOWELS
WITH ONE END FREE TO SLIP.
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail 6" Gutter
C-22
1'-4"
Slope 2% (14" / ft)
6"
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail Silt Fence
D-1
FLOW
FLOW
ROADWAY
FILL SLOPE
TYPICAL SILT FENCE PLACEMENT
6''
FILTER
FABRIC
TEMPORARY
SEDIMENT BUILD UP
EXISTING
GROUND
POST
SILT FENCE
1. SILT FENCE MATERIALS AND INSTALLATION SHALL MEET THE REQUIREMENTS OF THE ODOT
STANDARD SPECIFICATIONS, SECTION 221.
90°
90°
TEMPORARY SILT FENCE
RECOMMENDED TOE-IN METHOD TEMPORARY SILT FENCE
2°
2°
SECTION
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail RCP Bedding
D-3
DIA.
MI
N.
VA
RI
ES
COMPACTED BACKFILL
1' MIN.
1'
(TYP.)
SAND BACKFILL
1. THIS DETAIL COVERS THE INSTALLATION OF REINFORCED CONCRETE PIPE (RCP) USED AS DRAINAGE CONDUIT.
2. INSTALLATION AND MATERIALS SHALL MEET THE REQUIREMENTS OF THE ODOT STANDARD SPECIFICATIONS, SECTION 613.
3. TYPICAL SIZES IN USE ON TINKER AFB ARE 12", 15", 18" AND 24"."
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail Storm Sewer Inlet
D-6
Y+ 8"
X+8"
4"4"
8" 2'-6" 8" X=3'-10"
2"
4"4"
8" 8"
Y=4'-6"
2"
Y=2'-10"
B
B
A A
CONCRETE
COLLAR
NOTE: WALLS OF STORM
SEWER INLETS MAY BE OF
BRICK MASONRY OR OF
POURED CLASS A CONCRETE
TO THE SAME DIMENSIONS.
FINISH GRADE
EXISTING FRAME
AND INLET
NEW CONCRETE
COLLAR
CUT OFF LINE
OF OLD WALLS
* DISTANCE REQUIRED
TO REMOVE 2 COURSES
OF BRICK IN THE OLD WALL
** SAME FOR SINGLE AND DOUBLE GRATE INLET
SECTION A-A
2"
EXISTING FRAME
AND INLET
NEW CONCRETE COLLAR
SINGLE GRATE
DOUBLE GRATE
NOTE: SEE STORM SEWER
INLET NOTES ON DETAIL 6a.
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail
C-13 - 6
PLAN
SECTION B-B
SHAPE BOTTOM
OF TRENCH TO
CONTOUR OF PIPE
BOTTOM OF TRENCH
(UNDISTURBED EARTH)
42'' (MIN.) STEEL
OR WOOD POSTS
60'' (MAX.) SPACING
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
6'' (MIN.) FABRIC
IN TRENCH W/
BACKFILL
FILTER
FABRIC
1. ALL MATERIALS, EQUIPMENT AND CONSTRUCTION SHALL MEET THE REQUIREMENTS OF THE
OKLAHOMA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR HIGHWAY
CONSTRUCTION.
2. TOOLED OR SAWED JOINTS SHALL BE SPACED EVERY 10 FEET.
3. EXPANSION JOINTS SHALL BE PLACED EVERY 60 FEET.
4. EXPANSION JOINTS SHALL BE BRIDGED BY 4 EVENLY SPACED 24" X 1" DIAMETER SMOOTH DOWELS
WITH ONE END FREE TO SLIP.
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail PCC Drainage Flume
C-14
6"
8"
6"
8"
R3" R3"
R1
2" R1
2"
6" 6"
3" 6"
2'-8"
#3 bar (typ)
3" 1'-2" 1'-2" 1'-2" 3"
(M
IN
NEW #4 REBAR ON
6" C/C BOTH WAYS
#4 REBAR
AROUND STRUCTURE
2" CONCRETE COLLAR LINE
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
2"
NOT USED
Appr. Date: Rev. Date: Rev. No.: Detail No.:
Appr. By: Rev. BY: Title:
Tinker AFB, OK Standard Detail Storm Sewer Inlet Notes
D-6a
AIR FORCE MATERIEL COMMAND
72 ABW CIVIL ENGINEER DIRECTORATE
1. TO ADJUST THE EXISTING STRUCTURE TO NEW PAVEMENT ELEVATION (UP TO 6"):
A. REMOVE OLD FRAME AND GRATES.
B. REMOVE OLD STRUCTURE WALLS
· FOR BRICK: REMOVE A MINIMUM OF 2 COURSES OF BRICK IN THE OLD WALL.
· FOR CONCRETE: REMOVE A MINIMUM OF 6" OF STRUCTURE TOP.
C. STUB ANY NEW PIPE (IF APPLICABLE).
D. REPLACE NEW WALLS ADJUSTED TO NEW PAVEMENT ELEVATION.
· FOR CONCRETE: VERTICAL STEEL SHALL BE #4 BARS TO BE EPOXIED INTO THE OLD STRUCTURE WITH THE SAME SPACING AS EXISTING AND SHALL EXTEND TO WITHIN 2" OF TOP OF THE CONCRETE. HORIZONTAL STEEL SHALL BE
#4 BARS ON 6" C/C BOTH WAYS.
E. REINSTALL OLD FRAME AND GRATES. THE NEW GRATE ELEVATION SHALL BE1
2" BELOW THE SURROUNDING PAVEMENT.
F. INSTALL NEW 2" EXPANSION PREFORMED JOINT FILLER AROUND THE INLET STRUCTURE FOR CONCRETE PAVEMENT
(DEPTH OF PAVEMENT). NO EXPANSION JOINTS ARE NEEDED IN ASPHALT PAVEMENT.
2. TO MODIFY EXISTING INLET STRUCTURE FROM GRATES TO MANHOLE, ALL OF THE ABOVE NOTES APPLY EXCEPT FOR #5.
G. INSTALL NEW R6052-F NEENAH (OR EQUAL) MANHOLE FRAME, CONNECTORS AND LID. THE NEW MANHOLE TOP ELEVATION
SHALL BE EVEN WITH THE SURROUNDING PAVEMENT.
STORM SEWER INLET NOTES
| 01-100209-G01 |
| Sheets and Views |
| G01 |
| 12-100209-C11 |
| Sheets and Views |
| C11 |
| 16-100209-DT01 |
| Sheets and Views |
| DT01 |
File details come from the government source that posted it. Updated .