Bowling roof and envelope B5703 existing ref binder.pdf
PDF 4 MB Posted
- Solicitation number
- FA813726R0029
About this file
This document is a compilation of architectural and construction drawings for a bowling alley facility (Building B5703) spanning multiple renovation projects from 1962 to 1979.
The original 1962 construction file (File 610106) contains detailed architectural drawings including partial plot plans, floor plans for restroom facilities, plan details, steel frame details, roof plans, and reflected ceiling plans. Key specifications from the 1962 design include the bowling alley building with dimensions noting a finish floor elevation at 100 feet and bowling lane concrete slab at 97 feet 11 inches, representing a 2-foot 1-inch drop at the interior. Materials specified include Butler steel girt and monopanel construction, galvanized iron downspouts, face brick with 8-inch light weight concrete block, waterproof membrane applications, and various metal and masonry assemblies.
The 1975 addition project (File OC750229) documents a building expansion with comprehensive architectural and construction details. This file includes partial floor plans showing new restroom facilities with women's and men's toilet partitions and a new lavatory, checkered plate walk drain sections at the ramp bottom, sidewalk step sections at the south entry, room finish schedules, coping details, aluminum storefront framing details for door heads and sills, building sections, wall sections at brick and metal locations, handrail details using Blumcraft components, gutter sections, steel frame details at CMU and metal panel junctions, and a partial roof plan. The 1979 roof replacement project (File 790223) provides project drawings (not as-built) for roof repairs including roof plan partials, gutter and drain demolition details, roof section details through parapets, and roof penetration details, with notes indicating removal of parapet brick and coping and installation of new guttering and standing seam roof panels. Architectural comments note potential clogged weep holes at the south wall location requiring attention to drainage design.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Bowling roof and envelope B5703
FILE 610106: BOWLING ALLEY ORIGINAL PLANS
1962 OC 106 1 PARTIAL PLOT PLAN OCBA F 632011 SHT P1
1962 OC 106 1 PARTIAL BLDG PLOT PLAN OCBA F 632011 SHT P1
1962 OC 106 1 PARTIAL FUTURE ADD PLOT PLAN OCBA F 632011 SHT P1
1962 OC 106 1 PARTIAL FLOOR PLAN RESTROOM WOMEN OCBA F 6320 7
SHT A1
1962 PARTIAL FLOOR PLAN SOUTH WALL OCBA F 6320 7 SHT A1
1962 PLAN DETAIL F/8 OCBA F 6320 8 SHT A2
1962 PLAN DETAIL B/9 OCBA F 6320 8 SHT A3
1962 PLAN DETAIL D/9 OCBA F 6320 8 SHT A3
1962 STEL FRAME DETAIL 12/11 OCBA F 6320 11 SHT A5
1962 ROOF PLAN C/14 OCBA F 6320 11 SHT A8
1962 PARTIAL REFLECTED CEILING PLAN A/14 OCBA F 6320 14 SHT A8
CEILING AT RESTROOM, WOMEN
1962 OC 106 1 STEEL FRAMING SECTION SHT S-5
FILE OC750229 1975 ADDITION
1975 OC 229 3 6/2 CHECKERED PLATE WALK DRAIN SECTION @ BOTTOM RAMP
DE F 7618 2 SHT 2 OF 15
1975 OC 229 3 11/2 SIDEWALK STEP SECTION @ SOUTH ENTRY DE F 7618 2
SHT 2 OF 15
1975 OC 229 3 PARTIAL FLOOR PLAN DE F 7618 3 SHT 3 OF 15
1975 OC 229 3 ROOM FINISH SCHEDULE, PARTIAL DE F 7618 4 SHT 4 OF 15
1975 OC 229 3 DTL 1/4 & 2/4 COPING PLAN DE F 7618 4 SHT 4
OF 15
1975 OC 229 3 DTL 3/4 HEAD @ ALUM STOREFRONT DE F 7618 4
SHT 4 OF 15
1975 OC 229 3 DTL 4/4 HEAD @ HM DOOR DE F 7618 4 SHT 4 OF 15
1975 OC 229 3 DTL 5/4 SILL @ ALUM STOREFRONT DE F 7618 4 SHT 4
1975 OC 229 3 DTL 5/4 SILL @ ALUM STOREFRONT DE F 7618 4 SHT 4
1975 OC 229 3 SOUTH ELEVATION, PARTIAL DE F 7618 4 SHT 5 OF 15
1975 OC 229 3 SOUTH ELEVATION, PARTIAL DE F 7618 4 SHT 5 OF 15
1975 OC 229 3 BUILDING SECTION A-A DE F 7618 4 SHT 5 OF 15
1975 OC 229 3 BUILDING SECTION B-B, PARTIAL DE F 7618 4 SHT 5 OF 15
FINISH FLOOR @ ENTRY = 100’ FF – BOWLING LANE CONC SLAB [97’-11” FF] = 2’-1” DROP
@ INTERIOR
1975 OC 229 3 WALL SECTION, PARTIAL @ FLOOR 1/6 + 2/6 DE F 7618 4 SHT 6
1975 OC 229 3 WALL SECTION, PARTIAL @ BOWLING SLAB 3/6 DE F 7618 4 SHT 6
1975 OC 229 3 DTL 1/7 HANDRAIL - BLUMCRAFT DE F 7618 4 SHT 7 OF 15
1975 OC 229 3 DTL 4/7 GUTTER SECTION DE F 7618 4 SHT 7 OF 15
1975 OC 229 3 DTL 5/7 STEEL FRAME @ CMU / MTL PANEL PLAN DTL DE F
7618 4 SHT 7 OF 15
1975 OC 229 3 DTL 15/7 SILL @ HM DOOR DE F 7618 4 SHT 7 OF 15
1975 OC 229 3 DTL 16/7 JAMB @ HM DOOR DE F 7618 4 SHT 7 OF 15
1975 OC 229 3 DTL 18/7 HEAD @ HM DOOR DE F 7618 4 SHT 7 OF 15
1975 OC 229 3 2/8 ROOF PLAN, PARTITAL DE F 7618 8 SHT 8 OF 15
1975 OC 229 3 FOUNDATION PLAN, PARTIAL DE F 7618 9 SHT 9 OF 15
BOWLING SLAB @ 1204.92 ELEVATION [97.92”] + MAIN FLOOR @ 1207.0 ELEVATION
[100.0’]
1975 OC 229 3 PLUMBING PLAN, PARTIAL DE F 7618 11 SHT 11 OF 15
FILE 790223: 1979 ROOF REPLACEMENT
NOTE: PROJECT DRAWINGS – NOT “AS BUILT” OR VERIFIED. USE FOR REFERENCE ONLY.
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 ROOF PLAN, PARTIAL
DE F 7930 4 SHT 1 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 DTL 1/1 ROOF
GUTTER + DRAIN DEMO DE F 7930 1 SHT 1 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 DTL 2/1 ROOF
GUTTER DEMO DE F 7930 1 SHT 1 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 DTL 3/1 ROOF
GUTTER DEMO DE F 7930 1 SHT 1 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 DETAILS 1/4 DE F 7930 4
SHT 4 OF 4
REMOVAL OF GUTTER + BRICK PARAPET FROM 1975 ADDITION PROJECT – CONFIRM
SMACNA SIZE FOR EXTERIOR GUTTER INSTALLED 1979
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 ROOF PLAN, PARTIAL @ NE
CORNER, RESTROOM, WOMEN DE F 7930 2 SHT 2 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 ROOF PLAN, PARTIAL @ SE
CORNER DE F 7930 2 SHT 2 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 ROOF PLAN, PARTIAL @
SOUTH BOWLING WALL DE F 7930 2 SHT 2 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 1/2 ROOF SECTION
LOOKING EAST DE F 7930 2 SHT 2 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 6/2 & 7/2 ROOF
SECTION THRU PARAPET DE F 7930 2 SHT 2 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 6/2 & 7/2 ROOF
OUTSIDE CORNER @ PARAPET & EXTERNAL GUTTER DE F 7930 3 SHT 3 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 1/4 ROOF EAVE GUTTER
INFILL W/ EXTERNAL GUTTER DE F 7930 4 SHT 4 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 5/4 & 6/4 ROOF
PENETRATION DETAILS DE F 7930 4 SHT 4 OF 4
1979 OC 223 9 REPAIR ROOF BOWLING CENTER B5703 11/4 ROOF SECTION
THRU ROOFING TRANSITION DE F 7930 4 SHT 4 OF 4
NOTE: 1979 ROOF REPLACEMENT IS NOT AS BUILT DOCUMENT.
ARCHITECTURAL COMMENTS –
1. WEEP HOLES MAY BE CLOGGED AT SOUTH WALL. DETAIL INDICATES WEEP HOLES
ARE LOCATED AT JUNCTION BETWEEN CONCRETE GRADE BEAM AND FACE BRICK.
EXISTING GRADE APPEARS TO BE ABOVE CONCRETE GRADE BEAM – REFER 1/6,
2/6, & 3/6 WALL SECTION WEEP HOLES
2.