05703A-FP01 occupancy-Layout1.pdf
PDF 178 KB Posted
- Solicitation number
- FA813726R0029
About this file
This document is a floor plan and occupancy load analysis for a bowling center facility. The plan depicts a bowling alley with 18 lanes, bowlers' settees, spectator seating areas, and supporting spaces including offices, a cafe, kitchen, and locker rooms. The occupancy load calculations are based on standard capacity factors for each space type: bowling lanes are allocated at 5 persons per lane (totaling 90 occupants for the 18-lane facility), spectator areas at 1 occupant per 7 net square feet, office spaces at 1 occupant per 150 gross square feet, cafe at 1 occupant per 200 gross square feet, kitchen at 1 occupant per 50 gross square feet, and locker rooms at 1 occupant per 150 gross square feet. The facility's total design occupancy is 198 occupants, distributed across utility (7), bowling (90), spectator (71), office (3), cafe (14), kitchen (3), and locker room (10) functions. The layout includes a pinwheel corridor design with the bowling alley as the central feature and support spaces arranged around the perimeter. This appears to be a schematic design document used for space planning and code compliance purposes, rather than a solicitation document or contract requirement.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BOWLING LANES
PI
NS
ET
TE
R
AR
EA
BO
W
LE
RS
S
ET
TE
E
SP
EC
TA
TO
R
SE
AT
IN
G
CO
NC
OU
RS
E
XXX =OCCUPANCT LOAD FACTOR
XX SF
XX SPACE
150 GROSS = OCCUPANCT LOAD
FACTOR
179 SF
= 1 OCCUPANT
OFFICE SPACE
150 GROSS = OCCUPANCT LOAD
FACTOR
141 SF
= 1 OCCUPANT
OFFICE SPACE
15 NET = OCCUPANCT LOAD
FACTOR = 14 OCCUPANTS
211 SF
CAFE SPACE
200 GROSS = OCCUPANCT LOAD
FACTOR = 3 OCCUPANTS
627 SF
KITCHEN SPACE
50 GROSS = OCCUPANCT LOAD
FACTOR = 10 OCCUPANTS
507 SF
LOCKER RM SPACE
150 GROSS = OCCUPANCT LOAD
FACTOR = 1 OCCUPANT
96 SF
OFFICE SPACE
15 NET = OCCUPANCT LOAD FACTOR
1071 SF
= 71 OCCUPANTS
SPECTATOR SPACE
7 NET = OCCUPANCT LOAD FACTOR
1315 SF
18 LANES x 5 PERSONS = 90 OCCUPANTS
BOWLING LANES SPACE
[BOWLING CENTERS, ALLOW 5 PERSONS
FOR EACH LANE INCLUDING 15 FEET OF
RUNWAY, AND FOR ADDITIONAL AREAS
300 GROSS = OCCUPANCT LOAD
FACTOR = 1 OCCUPANT
175 SF
MECH SPACE
300 GROSS = OCCUPANCT LOAD
FACTOR = 1 OCCUPANT
56 SF
STORAGE SPACE
500 GROSS = OCCUPANCT LOAD
FACTOR = 1 OCCUPANT
212 SF
OFFICE SPACE
300 = OCCUPANCT LOAD FACTOR =
1 OCCUPANT
126 SF
ELECT SPACE
300 GROSS = OCCUPANCT LOAD
FACTOR = 1 OCCUPANT
86 SF
ELECT SPACE
300 GROSS = OCCUPANCT LOAD
FACTOR = 1 OCCUPANT
138 SF
STOCK SPACE
300 GROSS =OCCUPANCT LOAD
FACTOR = 1 OCCUPANT
236 SF
MECHANICAL SPACE
BOWLING ALLEY TOTAL
OCCUPANTS =
7 - UTILITY
90 - BOWLING
71 - SPECTATOR
3 - OFFICE
14 - CAFE
3 - KITCHEN
10 - LOCKER
198 TOTAL OCCUPANTS
La yo ut 1, 1/