2 Draft VCS SRD Tactical 4 Dec 23.docx

DOCX document 416 KB Posted

Attached to
Air Traffic Control Voice Communication Switch Replacement
Solicitation number
FA8102-23-R-2003
Issued by

About this file

This document is a System Requirements Document outlining the technical requirements for a replacement Tactical Voice Communication Switch to be procured by the Department of the Air Force Materiel Command Lifecycle Management Center Tinker Air Force Base. The new switch will replace an aging ProComm 1540 analog voice switch and must support air traffic control voice communication over an IP wide area network using VoIP, interface with currently used FAA and DoD air traffic control systems, and meet stringent environmental, reliability, maintainability and cybersecurity standards for tactical deployment. Key requirements include supporting 13 air-to-ground radios and 15 ground-to-ground lines per operator position, 99.8% operational availability, less than 30 seconds mean time to repair, and dual network redundancy. The solicitation number for this procurement opportunity is FA8102-23-R-2003.

View the file

Other files

File Type Posted
4 Draft VCS SRD Fixed Based 4 Dec 23.docx DOCX document
3 Draft VCS SRD Fixed Based 14 Nov 23.docx DOCX document
4 Draft ATC_VCS_SOW_ 14 Nov 23.docx DOCX document
1 Draft VCS SRD Tactical 14 Nov 23.docx DOCX document
VCS RFI QnA Final Sep 23.xlsx XLSX spreadsheet
VCS Industry Day Presentation Final.pptx PPTX presentation
Industry Day Notice.docx DOCX document
2 DRAFT VCS SRD v0 3Aug23.pdf PDF
3 DRAFT ATC_VCS_SOW_Clean V0 3Aug23.docx DOCX document
FINAL SSS RFI VCS 3 Aug 23.docx DOCX document
Contractor Data for Industry Day EAL.xlsx XLSX spreadsheet
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Tactical Voice Communication Switch System Requirements Document

For the Tactical Voice Communication Switch Document Number: [#] (Cage 98748) Version: 1 Version Date: 04 DEC 2023

Prepared By:

AFLCMC/HBAA

3508 D Ave., Bldg 201W, Room 74 Tinker AFB, OK 73145

Approved By: Approved By:

MARY M. COOLEY, NH-IV, DAFJAMES B. ROBERTS, GS-15, DAF
Chief, ATCALS Sus. & Mod. BranchDiv Chief, Programs and Requirements
Aerospace Management Systems DivisionHQ AFFSA

RECORD OF CHANGES

REVISIONS

Version#
description
date
approved
0
Original Release
14 Nov 2023
1
Removed Disclaimer
04 DEC 2023

Version: 1, 04 DEC 2023

DRAFT

Version: 1, 04 DEC 2023 Page 2 of 26

1. SCOPE

1.1. SYSTEM IDENTIFICATION. The USAF has a tactical voice switch installed in the AN/MSN-7 Communication Central, the USAF’s mobile air traffic control (ATC) tower. The MSN-7 voice switch is the ProComm 1540. The ProComm switch will be replaced with a tactical version of the VCS.

1.2. SYSTEM OVERVIEW. The ProComm 1540 is an analog voice switch that provides connectivity between an air traffic controller and the radios, telephone lines and other controllers. The ProComm is approaching 30 years old and the Original Equipment Manufacturer (OEM) has gone out of business, creating severe maintenance difficulties. In addition, as the USAF moves to Voice over Internet Protocol (VoIP) phone lines, the ProComm is unable to utilize these circuits. These difficulties have led to the decision to replace the ProComm with a digital system that is not Time Division Multiplexing based and that meets all ATC functionality.

1.3. DOCUMENT OVERVIEW. This System Requirements Document (SRD) provides performance requirements for procuring a replacement for the ProComm 1540.

1.4. REQUIREMENTS ORIGIN. Headquarters Air Force Flights Standards Agency (HQ AFFSA) provided two AF1067s, one titled Air Traffic Control Voice Control Switch/ ETVS Replacement dated 6 April 2023. This document is based upon those AF1067s, as well as on the ProComm (MSN-7 VCSS) specifications.

2. APPLICABLE DOCUMENTS

2.1. GENERAL. The applicable documents listed form a prerequisite to meet the requirements contained within this SRD. Documents marked with an asterisk (*) are specifically called out within subsequent specifications. Documents without asterisks (*) are not specifically called out but are still considered part of the base level requirement unless otherwise specified as “REFERENCE ONLY”.

2.2. GOVERNMENT DOCUMENTS. The following government documents form a part of this document to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.

2.3. CURRENT SYSTEM TECHNICAL ORDERS. These documents are to be used to determine the current configuration, procedures or anything related to use of the current fielded systems.

Table 2.3

Number
Title
Date
FAA Order 6400.1
Maintenance of Air Traffic Control Communication Services
3/6/2014
31R2-2MSN7-4-1907-1
Voice Communication Switching System, Instruction Manual, Rev C
3/15/2008
A1000158
CUI: Voice Communication Switching Subsystem (drawing)
5/20/2019

2.4. GENERAL TECHNICAL ORDERS

Table 2.4

Number
Title
Date
00-25-234
General Shop Practice Requirements for the Repair,

Maintenance, and Test of Electrical Equipment 10/27/2021

The following general Technical Orders are REFERENCE documents:

31-10-24
Installation Practices, Communications Systems grounding, Bonding, and Shielding
11/15/2011 reinstated 12/09/2019
31Z3-822-2
ATCALS Site Requirements
08/12/2019

2.5. INSTRUCTIONS AND MANUALS

Table 2.5

Number
Title
Date
AFMAN 91-203
Air Force Occupational and Environmental Safety, Fire Protection and Health (AFOSH) Standards

03/25/2022

AFMAN 11-231
Computed Air Release Point Procedures
11/18/2020
DoDI 4650.01
Policy and Procedures for Management and Use of the Electromagnetic Spectrum

10/17/2017

TM 3-34.43
Materials Testing
04/2015

The following Instructions and Manuals are REFERENCE documents: You are to use the latest date as of the date of proposal

AFMAN17-1203_AFGM2020-01
Information Technology Asset Management

09/13/2022

AFI 17-101
Risk Management Framework (RMF) for Air Force Information Technology (IT) as amended by Department of the Air Force Guidance Memorandum (DAFGM) to Air Force Instruction (AFI) 17-101, RMF for Department of The Air Force Information for Department of the Air Force Information Technology (IT)

02/05/2020 as amended 06/10/2022

AFI 17-130
Air Force Cybersecurity Program Management
02/13/2020
AFI 63-101/20-101
Integrated Life Cycle Management
06/30/2020
AFI 91-302
Air Force Occupational and Environmental Safety, Fire Protection and Health (AFOSH) Standards

4/18/94

AFMAN 13-204,

Vol 4

Radar, Airfield, and Weather Systems
07/22/2020
AFPD 13-2
Air Traffic, Airfield, Airspace and Range Management
01/03/2019
AFPD 17-1
Information Dominance Governance and Management
04/12/2016
DoDI 8510.01
Risk Management Framework (RMF) for DoD Systems
07/19/22

Public Law No: 113-283

SUBCHAPTER II--INFORMATION SECURITY

Federal Information Security Modernization Act of 2014 (FISMA 2014)
12/18/2014

2.6. SPECIFICATIONS, STANDARD, ORDERS AND ADVISORY CIRCULARS

Table 2.6

Number
Title
Date

The following Government Standard documents are MANDATORY and REQUIRE COMPLIANCE. The solution will be tested to or using the following Standards. You are to use the latest date as of the date of proposal.

MIL-HDBK-454C
General Guidelines for Electronic Equipment,

Note: Particular attention to be given to Guidelines 1, 5, 9, 15 & 66

09/21/2021

MIL-STD-129R_Chg2
Military Marking for Shipment and Storage
02/18/201409/27/2019

MIL-STD-130N

Chg 1

Identification Marking of U.S. Military Property (Notice 1)
12/17/200708/26/2019
MIL-STD-1472H
Human Engineering
09/15/2020
ANSI/ESD S20.20-2021
Protection Of Electrical And Electronic Parts, Assemblies And Equipment (Excluding Electrically Initiated Explosive Devices)
MIL-STD-188-124B
Grounding, Bonding and Shielding (Notice 4)
12/18/200004/04/2013
MIL-STD-2073-1E_Chg-4
DoD Standard Practice for Military Packaging
04/22/2019
MIL-STD-810H
Test Method Standard: Environmental Engineering Considerations and Laboratory Tests

05/18/2022

MIL-STD-461G
Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment

12/11/2015

MIL-STD-464D
Electromagnetic Environmental Effects Requirements for Systems
12/01/2010

12/24/2020

MIL-STD-882E
System Safety (w/Notice 1, 10 Feb 22)
05/11/201202/10/22
MIL-STD-810G
Test Methods: Environmental Engineering Considerations and Laboratory Tests
10/31/08
MIL-STD-882D
DoD Standard Practice for System Safety
2/10/00

EPA Title III, EPA 550-B-021-001

List of Lists, Consolidated List of Chemicals Subject to the Emergency Planning and Community Right-To-Know Act (EPCRA) and Section 112(r) of the Clean Air Act
04/2022

TM-86-01R

Air Force Technical Manual Contract Requirements (TMCR)
06/01/2020

The following Military Standard documents are REFERENCE documents

MIL-HDBK-310
Global Climatic Data for Developing Military Products
06/23/1997
MIL-HDBK-419A
Grounding, Bonding and Shielding for Electronic Equipment and Facilities, Volume 1 (Basic Theory) and Volume 2 (Applications) - w/Notice 1, 20 Feb 2014)
12/29/1987

02/20/2014

*MIL-E-4158E
General Requirements for Ground Electronic Equipment
1/11/1973
HF-STD-001B
FAA Human Factors Design
12/30/2016

2.7. INTERNATIONAL AGENCY DOCUMENTS

Table 2.7

Number
Title
Date

*ICAO Annex 10 Vol 1Fifth Edition

International Civil Aviation Organization (ICAO) International Standards and Recommended Practices, Aeronautical Telecommunications
(Latest)
EuroCAE ED-137/C
Interoperability Standards for VoIP ATM Components (Volume 1: Radio, Volume 2: Telephone, and Volume 4: Recording)
(Latest)

2.8. NON-GOVERNMENT DOCUMENTS

Table 2.8

Number
Title
Date
EN 55024
Information Technology Equipment – Immunity Characteristics – Limits and Methods of Measure
(Latest)
EN 55032
Electromagnetic Compatibility of Multimedia Equipment
(Latest)
NFPA-70
National Electrical Code, National Fire Protection Agency
(Latest)
NFPA-77
Recommended Practice on Static Electricity
(Latest)
GEIA STD 0005-1 Rev A
Performance Standard for Aerospace and High Performance Electronic Systems Containing Lead-free Solder
Mar 2012
GEIA STD 0005-2 Rev A
Standard for Mitigating the Effects of Tin Whiskers in Aerospace and High Performance Electronic Systems

May 2012

The following practices are REFERENCE documents:

IEEE Std 142-1991
Institute of Electrical and Electronics Engineers, Recommended Practices for Grounding of Industrial and Commercial Power Systems

(Latest)

IEEE Std 1100- Recommended Practices for Powering and Grounding of Electronic Equipment

(Latest)

IEEE Std 519-2014
Recommended Practice and Requirements for Harmonic Control in Electric Power Systems

(Latest)

*GEIA HB 0005-1 Rev A
Program Management / Systems Engineering Guidelines for Managing the Transition to Lead-free Electronics

Feb 2016

*GEIAHB00052
Technical Guidelines for Aerospace and Military Electronic Systems Containing Lead-free Solder
Nov 2007

2.9. SYSTEM REQUIREMENTS Contractor shall provide an organizational level Technical Order (TO) describing Operations & Maintenance procedures for the VCS in accordance with TO 00-5-1, para 3.5.2. Contractor shall provide an organizational level TO illustrating the VCS parts breakdown. Contractor shall provide a depot level TO describing detailed procedures in step-by-step form in accordance with TO 00-5-1, para 3.5.7. Contractor shall follow TO style and formatting requirements described in MIL-STD-38784.

2.10. SYSTEM FUNCTIONAL REQUIREMENTS System functional requirements are identified below within specific topics.

2.11. INTERFACE REQUIREMENTS

Table 2.11

Number
Description
Requirement
IF-1
External power
VCS shall provide external power conditioned via Uninterruptible Power System (UPS).
IF-2
Battery power
VCS shall provide battery power to sustain Critical Circuits for 20 minutes.

IF-3

(KPP)

Communication interface
VCS shall perform ATC voice communication over an IP Wide Area Network (WAN) using VoIP.

IF-4

(KPP)

Interoperability
VCS shall interface with currently used FAA and DoD Air Traffic Control systems and other command and control nodes to include communications transport via FTI/FENS, DISA Defense Information Systems Network Infrastructure Solutions (DISN IS) such as a DISA Multi‐Protocol Label Switching (MPLS) nodes, DISN Commercial Lease Transmission circuits supported through the General Service Administration Enterprise Infrastructure Services (GSA EIS) contracts, and/or DISN Gateway Solutions circuits supported through the Commercial Ethernet Gateway (CEG) contracts.
IF-5
Legacy analog interfaces types supported by external gateways/converters

Signaling

IF-5.1
2-Wire Private Branch Exchange (2W PBX)
Gateways/converters external to VCS shall provide 2W PBX capabilities as specified in 5.1.1-5.1.10: (Signal In, Signal Out)

IF-5.1.1

20 Hz, Loop start

IF-5.1.2

20 Hz, Ground start

IF-5.1.3

20 Hz + Caller ID , Loop + DTMF

IF-5.1.4

20 Hz + Caller ID, Ground + DTMF

IF-5.1.5

20 Hz Voice

IF-5.1.6

Voice (DoD), 20 Hz Manual (DoD)

IF-5.1.7

VOX, Voice

IF-5.1.8

20 Hz (DoD), 20 Hz (DoD)

IF-5.1.9

20 Hz, Loop + DTMF

IF-5.1.10

20 Hz, Ground + DTMF

IF-5.2
4-Wire Private Branch Exchange (4W PBX)
Gateways/converters external to VCS shall provide 4W PBX capabilities as specified in 5.2.1-5.2.4: (Signal In, Signal Out)

IF-5.2.1

VOX, Voice

IF-5.2.2

20 Hz, 20 Hz Manual

IF-5.2.3

20 Hz, Loop

IF-5.2.4

20 Hz + ID, Loop + DTMF

IF-5.3
Automatic Signaling Unit (ASU)
Gateways/converters external to VCS shall provide ASU capabilities as specified in 5.3.1-5.3.6: (Signal In, Signal Out)

IF-5.3.1

Loop start, 20 Hz auto

IF-5.3.2

Loop, 20 Hz manual

IF-5.3.3

VOX, 20 Hz manual

IF-5.3.4

VOX, 20 Hz auto

IF-5.3.5

Loop, Start Voice

IF-5.3.6

Loop + DTMF, 20 Hz auto

IF-5.4
E&M
Gateways/converters external to VCS shall provide E&M capabilities as specified in 5.4.1-5.4.6: (Signal In, Signal Out)

IF-5.4.1

E-lead (Voice In), M-lead (Voice Out)

IF-5.4.2

Tone-on-idle, Tone-on-idle

IF-5.4.3

Tone-on-active, Tone-on-active

IF-5.4.4

Tone-on-idle + DTMF, Tone-on-idle + DTMF

IF-5.4.5

E-lead + DTMF, M-lead + DTMF

IF-5.4.6

Signaling compatible with legacy radios using PTT contact closure signaling on E&M pair or TX-pair center-tap keying

IF-5.5
Selective/Signaling (SS)
Gateways/converters external to VCS shall provide SS1/4, 4/6/8 wire capabilities as specified in 5.5.1-5.5.7: (Signal In, Signal Out)

IF-5.5.1

2-digit SS dial, SS dial

IF-5.5.2

3-digit SS dial, SS dial

IF-5.5.3

2-digit SS dial, Voice

IF-5.5.4

3-digit SS dial, Voice

IF-5.5.5

VOX, SS dial

IF-5.5.6

2-digit SS dial, SS dial/voice

IF-5.5.7

3-digit SS dial, SS dial/voice

IF-6
External gateways/converters for legacy analog telephone interfaces
VCS shall provide gateways/converters external to switch as required for connections to legacy analog telephone interfaces meeting the ED-137C Volume 2 Specification for Telephone Interfaces and the following addendums: - Addendum 2, FAA Legacy Telephone Interworking: Covers the overall translation between FAA Legacy G/G calls and ED-137 protocol

- Addendum 4, Override Call

- Addendum 5, Voice Call

- Addendum 6, Extended Call Forward: Covers FAA 's additional requirements for Call Forward

IF-7
Voice recording
VCS shall interface all ED-137C voice communication with the NAS Voice Recorder (NVR), all versions.
IF-8
Brightness
VCS system brightness shall be adjustable for operator preference and suitable for all MSN-7 lighting conditions.
IF-9
Radios
VCS shall interface with General Dynamics URC-300 radios, all versions.

2.12. OPERATIONAL REQUIREMENTS

Table 2.12

Number
Description
Requirement
OP-1
A/G and G/G connection
System shall establish duplex connection within 230 msec.
OP-2
System Reconfiguration

OP-2.1

System shall reconfigure frequencies and voice channels to controller positions in less than 60 seconds.

OP-2.2

System reconfiguration shall result in a service interruption of less than 6 seconds.

OP-3 (KPP)
Voice recording
VCS shall interface all voice communication with the NAS Voice Recorder (NVR).
OP-4
Air-To-Ground (A/G) Keys, Features, & Indicators
OP-4.1
Frequency Selection

OP-4.1.1

The VCS shall assign any combination of A/G frequencies; both transmitter and receiver, to any operator position as configured by authorized access levels.

OP-4.1.2

The VCS shall permit assignment of a single frequency multiple times at a single operator position each functioning as a distinct frequency as configured by authorized access levels.

OP-4.1.3

The VCS shall continuously display at least 13 alphanumeric character frequency designations for each frequency assigned to each operator position.

OP-4.1.4

The VCS shall provide single action latching selection / deselection for each frequency.

OP-4.1.5

The VCS shall provide transmitter connectivity for any combination of A/G frequencies selected at an operator position; minimum of 30 frequencies displayable.

OP-4.1.6

The VCS shall provide A/G receiver audio to the operator position for any combination of A/G frequencies selected at the operator position.

OP-4.1.7

The VCS shall preclude selection / deselection of transmitters and receivers at one operator position from affecting selection / deselection of transmitters and receivers at other positions.

OP-4.2
Frequency Display Values

OP-4.2.1

VCS A/G frequency values shall be displayed with values in MHz and decimal fractions thereof.

OP-4.2.2

VCS VHF A/G frequency values shall be displayed to the nearest 0.025 MHz (e.g., 125.550) with the extension for 8.33 kHz channel spacing displayed as * (e.g., 125.550*).

OP-4.2.3

VCS UHF A/G frequency values shall be displayed to the nearest 0.025MHz (e.g., 217.325).

OP-4.2.4

All VCS A/G frequency indications shall have a decimal point separating the integer and fractional portions of the frequency value.

OP-4.3
Transmitter (TX) Status

OP-4.3.1

The VCS shall provide, by adaptation, continuous green visual indications of transmitter (TX) status at each operator position where a frequency has been selected. If more than one position has the same frequency selected, each should indicate green. Orange visual indications of transmitter (TX) selected tatus should appear for frequency status assigned to other positions with frequency unselected.

OP-4.3.2

The VCS shall provide continuous green visual indication of each TX selected but idle.

OP-4.3.3

The VCS shall provide flutter green visual indication of TX selected and keyed at each operator position activating PTT.

OP-4.3.4

The VCS shall provide flutter green visual indication of each TX selected and keyed at a second operator position activating PTT.

OP-4.3.5

The VCS shall provide flashing red visual indication of each TX not selected and keyed at a second operator position.

OP-4.4
Receiver (RX) Status

OP-4.4.1

The VCS shall provide continuous green visual indications of receiver (RX) status at each operator position where a frequency has been assigned.

OP-4.4.2

The VCS shall provide continuous green visual indication of each RX selected but idle.

OP-4.4.3

The VCS shall provide flashing green visual indication of each RX selected and audio being received as indicated by squelch break.

OP-4.4.4

The VCS shall provide fluttering green visual indication of each RX not selected and audio being received at a second operator position as indicated by squelch break.

OP-4.5
Main/Standby A/G Selection/Deselection
OP-4.5.1
Main/Standby Transmitter (TX) Selection/Deselection

OP-4.5.1.1

The VCS shall provide single action latching operator position controls to select either main or standby transmitter for each frequency.

OP-4.5.1.2

The VCS shall provide continuous visual indication at the operator position of the transmitter in use, either main or standby.

OP-4.5.1.3

The VCS shall preclude selection of a standby transmitter where no connection exists providing a simultaneous visual and audible indication of an invalid selection.

OP-4.5.2
Main/Standby Receiver (RX) Selection/Deselection

OP-4.5.2.1

The VCS shall provide single action latching operator position controls to select either main or standby receiver for each frequency.

OP-4.5.2.2

The VCS shall provide continuous visual indication at the operator position of the transmitter in use, either main or standby.

OP-4.5.2.3

The VCS shall preclude selection of a standby receiver where no connection exists providing a simultaneous visual and audible indication of an invalid selection.

OP-4.6
Unmonitored Receiver Report
The VCS shall provide a continuous visual indication and simultaneous alarm to authorized access levels when any A/G frequency assigned to operator positions is not selected for receive by at least one operational position.
OP-4.7
Frequency Forwarding

OP-4.7.1

The VCS shall provide operator position controls to forward all frequencies assigned from one position to another, as configured by authorized access levels.

OP-4.7.2

The VCS shall provide a continuous visual indication at the operator position of frequency forwarding in use including identification of the forwarded-to position.

OP-4.8
Frequency Add/Delete
The VCS shall provide operator position controls to add/delete frequencies, as configured by authorized access levels.
OP-4.9
Emergency Radio Designation
The VCS shall provide controls for authorized access levels to designate emergency radio transmitters and receivers.
OP-4.10
Emergency Frequency Selection

OP-4.10.1

The VCS shall provide every air traffic controller position that has A/G capabilities ability to transmit, receive and monitor to the UHF and VHF emergency frequencies 243.0 MHz and 121.500 MHz.

OP-4.10.2

The VCS shall uniquely mark single touch action button for emergency frequencies as “ERAD PTT’ on operational interactive displays.

OP-4.10.3

The VCS shall provide transmission on either UHF or VHF emergency frequency individually and/or both frequencies simultaneously via single, continuous, nonlatching touch action by the position operator.

OP-4.10.4

The VCS shall transmit selected emergency frequency (frequencies) over all other selected frequencies that are selected and have TX enabled, for the duration of the single, continuous, nonlatching operator touch action.

OP-4.10.5

The VCS shall provide a visual indication to every position operator with emergency frequency assignment to notify of the activation of an emergency UHF/VFH frequency transmitter.

OP-4.11
Emergency Frequency Lockout

OP-4.11.1

Activation of a transmitter for either 243.0 MHz and 121.500 MHz emergency frequency at an operational position shall lock out use of that transmitter at all other operational positions for the duration of the emergency transmission.

OP-4.11.2

The VCS shall provide the position operator at a locked-out position a visual and audible indication that the emergency frequency access has been locked out if PTT is attempted on the emergency frequency.

OP-5
Ground-To-Ground (G/G) Keys, Features, & Indicators
OP-5.1
Placement and Reception of G/G Calls

OP-5.1.1

The VCS shall provide operator position controls to place and receive G/G calls of all types per Interface Section IF-5.

OP-5.1.2

The VCS shall provide operator position controls to place and receive G/G calls in all modes per Interface Section IF-5.

OP-5.2
Keypad

OP-5.2.1

The VCS shall provide standard telephone keypad functionality for operator positions.

OP-5.2.2

The VCS shall automatically deactivate the keypad 15 seconds after entry of the last digit or activation of the keypad, whichever is later

OP-5.2.3

The VCS shall suspend automatic keypad deactivation for IP calls where additional dialing is required to complete the call.

OP-5.3
Incoming Call Indication
OP-5.3.1
Visual Indications

OP-5.3.1.1

The VCS shall display continuous visual indications of incoming calls, including voice calls, at the operator position.

OP-5.3.1.2

The VCS shall display continuous visual indications of voice circuit(s) in use.

OP-5.3.1.3

The VCS shall display, on the currently selected operator screen display, visual indications of incoming calls to DA selectors assigned to operator screen pages that are not currently selected.

OP-5.3.2
Chime Indications

OP-5.3.2.1

The VCS shall provide audible chime indications at the operator position for incoming G/G calls, except voice calls and OVR calls.

OP-5.3.2.2

The VCS shall automatically discontinue chime indications when a G/G call has been answered.

OP-5.3.2.3

The VCS shall provide operator position controls to adjust the chime volume.

OP-5.3.2.4

The VCS shall provide a choice of distinctive chime sounds, as configured by authorized access levels.

OP-5.3.2.5

The VCS shall provide operator control to deactivate chime indications.

OP-5.3.2.6

The VCS shall provide a continuous visual indication of chime activation status.

OP-5.4
Call Types

OP-5.4.1

The VCS shall provide placement and reception of the Intercom (IC) at all operator positions as configured by authorized access levels.

OP-5.4.2

The VCS shall provide placement and reception of the Interphone (IP) at all operator positions as configured by authorized access levels.

OP-5.4.3

The VCS shall provide placement and reception of the Override (OVR) at all operator positions as configured by authorized access levels.

OP-5.5
Call Modes

OP-5.5.1

The VCS shall provide placement and reception calls in Direct Access (DA) mode at all operator positions.

OP-5.5.2

The VCS shall provide placement and reception in Indirect Access (IA) mode at all operator positions.

OP-5.5.3

The VCS shall provide voice call signaling.

OP-5.6
Override (OVR)

OP-5.6.1

The VCS shall connect OVR calls without action on the part of the called party.

OP-5.6.2

The VCS shall provide momentary audible indications of incoming OVR calls at operator positions as configured by authorized access levels.

OP-5.6.3

The VCS shall provide continuous visual indications of incoming OVR calls at operator positions.

OP-5.6.4

The VCS shall provide continuous visual indications of OVR calls in progress at operator positions.

OP-5.6.5

The VCS shall permit OVR calls to be placed in IA mode.

OP-5.6.6

The VCS shall permit OVR calls to be placed in DA mode.

OP-5.7
Call Transfer

OP-5.7.1

The VCS shall provide call transfer at operator positions.

OP-5.7.2

The VCS shall provide operator position controls to transfer incoming calls on a per call basis from one operator position to another.

OP-5.7.3

The VCS shall transfer calls using a three-step process wherein the operator manually selects the transfer feature, then places a call to a second position, and manually releases the call before completing the process.

OP-5.7.4

The VCS shall permit call transfer to include the transferring operator position on the transferred call or to release from the call without affecting the call transfer between the calling party and transferred-to-position.

OP-5.8
Speed Dial
The VCS shall provide speed dial at operator positions.
OP-5.9
Conference Calls
OP-5.9.1
General Conference Call Requirements

OP-5.9.1.1

The VCS shall provide operator position controls to initiate, and participate in, conference calling.

OP-5.9.1.2

The VCS shall provide continuous visual indication at the operator position of participation in a conference.

OP-5.9.1.3

The VCS shall provide operator position controls to place a conference on hold.

OP-5.9.1.4

The VCS shall provide a continuous visual indication at the operator position of conference on hold.

OP-5.9.1.5

The VCS shall automatically release a conference call in progress upon release by the last party to a conference.

OP-5.9.2
Preset Conferences

OP-5.9.2.1

The VCS shall provide operator position controls to initiate preset conferences using single action selectors, as configured by authorized access levels at operator positions.

OP-5.9.2.2

The VCS shall provide controls for authorized access levels to define preset lists of callers for preset conferences of at least 50 participants.

OP-5.10
Caller Identification (Caller ID)
The VCS shall display at the operator position the caller ID for incoming calls and lines that provide caller identity information including DA calls.
OP-5.11
Hook Flash
The VCS shall provide hook flash as configured by authorized access levels.
OP-5.12
Manual Ring
The VCS shall provide manual ringdown as configured by authorized access levels.
OP-5.13
Privacy
The VCS shall provide privacy on selected interphone circuits as configured by authorized access levels.
OP-5.14
Call Queue / Common Answer (CA)
OP-5.14.1
Call Queuing

OP-5.14.1.1

The VCS shall direct incoming G/G calls to each operator position that do not have a corresponding DA selector assigned to a common answer call queue.

OP-5.14.1.2

The VCS shall queue calls to a depth of four calls including the call in-progress and calls on-hold.

OP-5.14.1.3

The VCS shall provide operator position controls to selectively answer calls from the call queue.

OP-5.14.2
Call Queue / CA Display

OP-5.14.2.1

The VCS shall display the idle state of the CA call queue at each position.

OP-5.14.2.2

The VCS shall display the incoming / ringing state of the CA call queue at each position.

OP-5.14.2.3

The VCS shall display the active state of the CA call queue at each position.

OP-5.14.2.4

The VCS shall display the hold state of the CA call queue at each position.

OP-5.15
Call Release

OP-5.15.1

The VCS shall release G/G calls in progress at an operator position, except OVR calls, through deselection of the assigned DA selector at the operator position.

OP-5.15.2

The VCS shall release G/G calls in progress at an operator position answered from the CA queue through deselection of the CA selector.

OP-5.15.3

The VCS shall provide operator controls that release G/G calls in progress, except OVR calls, using a single action non-latching selector.

OP-5.15.4

The VCS shall release G/G calls in progress at an operator position, except OVR calls, by placement of another G/G call.

OP-5.15.5

The VCS shall release G/G calls in progress at an operator position, except OVR calls, by resuming a call previously placed on hold.

OP-5.15.6

The VCS shall release OVR calls from the receiving operator position upon entry of an assigned IA code.

OP-5.15.7

The VCS shall automatically release incoming IP calls on voice circuits that do not have supervisory signaling within a configurable time limit configurable by authorized access levels.

OP-5.16
Call Hold

OP-5.16.1

The VCS shall provide single action, non-latching, operator position controls to place the G/G call in progress on hold.

OP-5.16.2

The VCS shall provide a continuous visual indication at the operator position of all calls on hold.

OP-5.16.3

The VCS shall permit the placement of other A/G and G/G calls while calls are on hold at an operator position.

OP-5.17
Single Button Crash Alarm (SBCA) Primary Crash

OP-5.17.1

The VCS shall provide continuous connectivity between operator positions and external stations using a single button control to activate a primary crash alarm.

OP-5.17.2

The VCS SBCA shall support at a minimum of six single phone agencies.

OP-5.17.3

The VCS SBCA shall be activated by pressing the SBCA button twice to avoid unintentional activation.

OP-5.17.4

The VCS SBCA shall provide simultaneous ring out to all parties connected and preconfigured at the distant end once SBCA has been activated by the Controller position.

OP-5.17.5

The VCS shall provide green visual indicators for each preconfigured connection (e.g., Fire Dept, AMOPS, CP, etc.) associated with the distant end connection, and when activated, green indicators will activate in steady state until the distant end answers the call.

OP-5.17.6

The VCS shall provide a green flutter indication on the DA button associated with the distant end connection when the distant end answers the SBCA call.

OP-5.17.7

The VCS shall provide audible ring tone when SBCA is activated and unanswered phones will continue to ring until the distant end connection is picked up (off the hook) or the SBCA conference is terminated by the control position.

OP-5.17.8

The VCS shall provide an additional audible tone indicating when distant end users have picked up (off the hook) their conference line.

OP-5.17.9

The VCS shall allow after the first distant end answers the SBCA call or upon a third selection of the SBCA button, the ring back call progress tone to be removed, but the unanswered conference parties will continue to ring or chime at the distant end.

OP-5.17.10

The VCS shall allow the SBCA call originator to disconnect an agency from the conference by pressing the DA button that associates with distant end agency or the ‘REL’ key. Note that pressing the ‘REL’ key will terminate the call to all agencies. The SBCA green bar indicator on the DA button will disappear upon the call termination.

OP-5.17.11

The VCS shall provide the distant end agency the ability to disconnect itself from the conference by hanging the phone up.

OP-5.17.12

The VCS shall allow all parties to hear and communicate with each other when a SBCA conference is established.

OP-5.17.13

The VCS shall allow only control positions the ability to activate the SBCA.

OP-5.17.14

The VCS shall the control position responsible for activating the SBCA conference the ability to terminate the SBCA conference by pressing the ‘REL’ key display screen. All parties will be disconnected upon termination by originator and the indicators will return to the normal idle states.

OP-5.18
Single Button Crash Alarm (SBCA) Secondary Crash Network

OP-5.18.1

The VCS shall provide progressive connectivity between operator positions and external stations using a single button control to activate a Secondary Crash Network (SCN).

OP-5.18.2

The VCS (SCN) shall support up to 100 single phone agencies.

OP-5.18.3

The VCS SCN shall be activated by pressing the SCN button twice to avoid unintentional activation.

OP-5.18.4

The VCS SCN shall provide simultaneous ring out to all parties connected and preconfigured at the distant end once SCN has been activated by the Controller position.

OP-5.18.5

The VCS shall provide green visual indicators for each preconfigured connection (e.g., Fire Dept, AMOPS, CP, etc.) associated with the distant end connection, and when activated, green indicators will activate in steady state until the distant end answers the call.

OP-5.18.6

The VCS shall provide a green flutter indication on the DA button associated with the distant end connection when the distant end answers the SCN call.

OP-5.18.7

The VCS shall provide audible ring tone when SCN is activated and unanswered phones will continue to ring until the distant end connection is picked up (off the hook) or the SCN conference is terminated by the control position.

OP-5.18.8

The VCS shall provide an additional audible tone indicating when distant end users have picked up (off the hook) their conference line.

OP-5.18.9

The VCS shall allow after the first distant end answers the SCN call or upon a third selection of the SCN button, the ring back call progress tone to be removed, but the unanswered conference parties will continue to ring or chime at the distant end.

OP-5.18.10

The VCS shall allow the SCN call originator to disconnect an agency from the conference by pressing the DA button that associates with distant end agency or the ‘REL’ key. Note that pressing the ‘REL’ key will terminate the call to all agencies. The SCN green bar indicator on the DA button will disappear upon the call termination.

OP-5.18.11

The VCS shall provide the distant end agency the ability to disconnect itself from the conference by hanging the phone up.

OP-5.18.12

The VCS shall allow all parties to hear and communicate with each other when a SCN conference is established.

OP-5.18.13

The VCS shall allow only controller positions the ability to activate the SCN.

OP-5.18.14

The VCS shall ensure the control position responsible for activating the SCN conference the ability to terminate the SCN conference by pressing the ‘REL’ key display screen. All parties will be disconnected upon termination by originator and the indicators will return to the normal idle states.

OP-6
Combined A/G & G/G Functions
OP-6.1
A/G - G/G Coupling

OP-6.1.1

The VCS shall provide operator position controls to enable/disable a one-way audio connection between A/G communications at a position and any G/G calls in progress at the position, as configured by authorized access levels.

OP-6.1.2

The VCS shall provide audio from A/G calls to the audio connection when PTT is active and the coupling has been enabled.

OP-6.1.3

The VCS shall preclude audio from G/G calls in progress at the position from being transmitted over A/G frequencies.

OP-6.1.4

The VCS shall provide a continuous visual indication at the operator position indicating the selection of A/G – G/G coupling.

OP-6.2
Position Relief Briefing

OP-6.2.1

The VCS shall establish an audio connection between the Operator and Monitor at each Headset (HS) interface at an operator position activating microphones at both interfaces.

OP-6.2.2

The VCS shall establish an audio connection between HS interfaces at an operator position where the position is configured for 4-jack operation.

OP-6.2.3

The VCS shall provide activation / deactivation of position relief briefing functionality through a single action latching selector.

OP-6.2.4

The VCS shall temporarily suspend the audio connection when an A/G or G/G is in progress.

OP-6.2.5

The VCS shall provide a continuous visual indication at the operator position of the selection of relief briefing functionality.

OP-6.2.6

The VCS shall provide position relief briefing audio to the facility legal recorder.

OP-7
Audio Routing
OP-7.1
Master Loudspeaker (LS) Audio Routing

OP-7.1.1

The VCS shall provide operator position controls that route all incoming audio from A/G calls and G/G calls, including OVR, to the position loudspeaker regardless of Headset/Loudspeaker routing settings for individual frequencies as configured by authorized access levels.

OP-7.1.2

The VCS shall provide a continuous visual indication at the operator position of the state of the selection of Master Loudspeaker audio routing.

OP-7.2
Automatic A/G LS Routing

OP-7.2.1

The VCS shall route incoming A/G call audio to the position loudspeaker during G/G calls, except OVR calls, as a facility setting configured by authorized access levels.

OP-7.2.2

The VCS shall provide single action latching operator position controls to disable the facility setting for automatic routing of A/G calls as configured by authorized access levels.

OP-7.2.3

The VCS shall route incoming A/G audio to the operator position headset/handset when the facility A/G LS routing setting has been disabled at an operator position, a G/G call is in progress, and G/G audio routing to the headset/handset has been selected.

OP-7.2.4

The VCS shall provide a continuous visual indication at the operator position of the automatic A/G audio routing selection in effect.

OP-7.3
A/G LS Routing

OP-7.3.1

The VCS shall provide single action latching operator position controls that route incoming A/G audio to the operator position LS regardless of HS/LS routing settings for individual frequencies, as configured by authorized access levels.

OP-7.3.2

The VCS shall provide a continuous visual indication at the operator position of the A/G LS Routing setting in effect.

OP-7.4
A/G Audio Routing for Unattended Positions
The VCS shall automatically route incoming A/G call audio for positions without a headset connected (unattended) to the position loudspeaker(s).
OP-7.6
Frequency Muting
OP-7.6.1
Local Muting

OP-7.6.1.1

The VCS shall provide single action latching operator position controls for local muting at the position of the audio of any receiver frequency(s) in use at the position.

OP-7.6.1.2

The VCS shall provide a continuous visual indication at the operator position of local muting selection.

OP-7.6.2
Remote Muting

OP-7.6.2.1

For interfaces that provide remote muting capability, the VCS shall provide remote muting for operator-selected frequencies as configured by authorized access levels.

OP-7.6.2.2

The VCS shall provide single action latching operator position controls to select/deselect remote mute for each A/G frequency assigned to the position.

OP-7.6.2.3

The VCS shall provide a continuous visual indication at the operator position of remote muting selection regardless of local muting status.

OP-7.7
Per Frequency Audio Routing

OP-7.7.1

The VCS shall provide position controls to route receiver audio to either the operator headset (HS) or the position loudspeaker(s) (LS) for each frequency assigned to an operator position.

OP-7.7.2

The VCS shall provide single action latching controls for per frequency audio routing.

OP-7.7.3

The VCS shall provide a continuous visual indication of audio routing selection for each frequency assigned to an operator position.

OP-7.7.4

The VCS shall provide audio output at the operator position configurable to present audio from both A/G and G/G through a single loudspeaker.

OP-7.8
Manual G/G Audio Routing

OP-7.8.1

The VCS shall provide single action latching operator position controls for manual routing of G/G audio for individual voice circuits to either the operator handset or position loudspeaker, as configured by authorized access levels.

OP-7.8.2

The VCS shall route incoming audio for voice calls to the operator position LS for all operator positions on the circuit bearing the call.

OP-7.8.3

The VCS shall provide a continuous visual indication at the operator position of G/G audio routing selection in effect for individual voice circuits.

OP-7.9
G/G LS Audio Routing

OP-7.9.1

The VCS shall provide single action latching operator position controls that route all incoming G/G audio to the operator position G/G LS regardless of HS/LS routing settings for individual voice circuits, as configured by authorized access levels.

OP-7.9.2

The VCS shall provide a continuous visual indication at the operator position of G/G audio routing selection in effect.

OP-7.10
G/G Audio Routing for Unattended Positions
The VCS shall automatically route incoming G/G call audio for unattended operator positions to the position loudspeaker(s).
OP-7.11
G/G Non-OVR Audio Routing Precedence
The VCS shall provide the following precedence for non-OVR G/G audio routing functions in descending order of precedence.
OP-7.12
G/G OVR Audio Routing

OP-7.12.1

The VCS shall provide single action latching operator position controls to route incoming OVR calls to either the operator headset or position loudspeaker, as configured by authorized access levels.

OP-7.12.2

The VCS shall provide a continuous visual indication at the operator position of G/G OVR audio routing selection.

OP-7.12.3

The VCS shall provide the following precedence for OVR G/G audio routing functions in descending order of precedence.

OP-7.13
Order of Precedence

OP-7.13.1

The VCS shall provide unattended position routing to the operator position LS.

OP-7.13.2

The VCS shall provide Master LS Routing, if assigned.

OP-7.13.3

The VCS shall provide G/G LS Routing, if assigned.

OP-8
A/G & G/G Keying/Push-To-Talk (PTT)
OP-8.1
A/G Keying/PTT
OP-8.1.1
A/G Keying/PTT Option 1
The VCS shall provide a push-to-talk option that upon PTT activation simultaneously connect the operator position to the selected A/G transmitters, key these transmitters, and transfer all incoming G/G audio to the position LS except for incoming override (OVR) calls.

OP-8.1.1.1

The VCS shall provide PTT transmission of A/G and G/G frequencies, except emergency.

OP-8.1.1.2

VCS shall upon PTT release simultaneously un-key selected A/G transmitters, disconnect the operator position from these transmitters, and resume all incoming G/G call audio.

OP-8.1.1.3

The VCS shall preclude transmission of G/G audio over A/G frequencies.

OP-8.1.1.4

The VCS shall provide PTT Option number one as the default setting.

OP-8.1.2
A/G Keying/PTT Option 2
The VCS shall provide a push-to-talk option identical to A/G PTT option number one except upon PTT activation shall preclude connection to A/G transmitters or key these transmitters until all ongoing G/G calls have been terminated, except for incoming OVR calls.
OP-8.2
PTT Lockout / Key-to-Lockout

OP-8.2.1

The VCS shall preclude more than one position from transmitting on a single frequency at a single time.

OP-8.2.2

The VCS shall provide simultaneous visual and audible indications of PTT lockout to second and subsequent positions attempting to transmit on a frequency as long as the lockout condition is active.

OP-8.2.3

The VCS shall terminate PTT lockout and indications when the frequency is available for use.

OP-8.2.4

The VCS shall provide simultaneous audible and visual indications of lockout per frequency to second and subsequent positions as long as the lockout condition is active.

OP-8.3
G/G PTT
OP-8.3.1
General G/G PTT
The VCS shall provide all call audio, including sidetone, to all headset interfaces at an operator position.
OP-8.4
G/G PTT Option #1
The VCS shall provide a push-to-talk option configurable by authorized access levels that permits transmission audio on G/G calls without using PTT.
OP-8.5
G/G PTT Option #2

OP-8.5.1

The VCS shall provide a push-to-talk option configurable by authorized access levels that permits transmission audio on G/G calls using PTT.

OP-8.5.2

The VCS shall provide audio from a headset interface activating PTT to the G/G call subject to local or 4-jack preemption, except incoming OVR calls.

OP-9
General Position Functions
OP-9.1
Position Monitoring

OP-9.1.1

The VCS shall provide operator position controls that allow any single operator position to monitor audio directed to, and emanating from, at least three other positions, as configured by authorized access levels.

OP-9.1.2

The VCS shall preclude indications of monitoring in progress at monitored positions.

OP-9.1.3

The VCS shall provide a continuous visual indication at the monitoring position of position monitoring selection.

OP-9.1.4

The VCS shall provide a continuous visual indication at the monitoring position of which position(s) are being monitored.

OP-9.1.5

The VCS shall preclude loop closure of position monitoring between monitoring and monitored positions.

OP-9.1.6

The VCS shall automatically suspend voice monitoring in the presence of incoming A/G and G/G calls.

OP-9.2
Split Position Operation

OP-9.2.1

The VCS shall provide operator position controls to permit division of the communications assigned to a position between A/G and G/G on a non-interfering basis, as configured by authorized access levels.

OP-9.2.2

The VCS shall automatically disable the automatic audio routing operator controls at a position when split operation is selected at the position.

OP-9.2.3

The VCS shall apply the master loudspeaker transfer to the G/G side of the split position.

OP-9.2.4

The VCS shall provide a continuous visual indication at the operator position of the selection of split operation.

OP-9.3
Four-Jack Operation
OP-9.3.1
Headset (HS)

OP-9.3.1.1

The VCS shall permit the use of two PJ-7 compatible HS interfaces at selected operator positions wherein each HS interface each provides for Operator and Monitor pair.

OP-9.3.1.2

The VCS shall prove up to two HS interfaces for each operator position, if ordered.

OP- 9.3.1.3

The VCS shall provide HS interface devices capable of connecting two HS peripherals, designated as “Operator” and “Monitor”, simultaneously.

OP-9.3.2
Hand Microphone interface

OP-9.3.2.1

The VCS shall provide a hand microphone interface for selected operator positions.

OP-9.3.2.2

The VCS shall provide a connection for a hand microphone.

OP-9.3.2.3

The VCS shall provide hand microphones that provide PTT signaling.

OP-9.3.2.4

The VCS shall provide hand microphone volume control.

OP-9.3.3
Footswitch Interface

OP-9.3.3.1

The VCS shall provide a footswitch interface capable of providing PTT signaling, as ordered, for selected operator positions.

OP-9.3.3.2

The VCS shall provide a connection for a footswitch.

OP-9.3.3.3

The VCS shall provide a footswitch, as ordered.

OP-9.3.3.4

The VCS shall, at operator positions configured for 4-jack operation, accept footswitch PTT signaling from the first operator/monitor pair only.

OP-9.4
Position Preemption
When four-jack operation is available at a position, the VCS shall perform position preemption in the following order and priority.
OP-9.4.1
Order & Priority

OP-9.4.1.1

The first Monitor PTT shall preempt the first Operator and the second pair. (Highest priority)

OP-9.4.1.2

The first Operator shall preempt the second pair.

OP-9.4.1.3

The second Monitor shall preempt the second operator.

OP-9.4.1.4

The second Monitor shall be precluded from preempting the first pair.

OP-9.4.1.5

The second Operator shall have the lowest priority.

OP-9.4.1.6

The VCS shall provide the preempting monitor transmit audio to all lower priority HS interfaces.

OP-9.7
Page Navigation
The VCS shall provide operator position controls to permit navigation between pages displayed on operator position screens.
OP-9.8
Supervisor Management Functions

OP-9.8.1

The VCS shall provide supervisory position controls with access to configure any combination of operator positions to perform any A/G function, as configured by authorized access levels.

OP-9.8.2

The VCS shall permit supervision of subsets of operator positions from supervisory positions as configured by authorized access levels.

2.13. TOWER/RADAR COORDINATION Tower/radar coordination is not required.

2.14. CAPACITY REQUIREMENTS VCS shall meet the following capacity requirements:

Table 2.14

Number
Description
Requirement
CAP-1
Number of positions
3 controller, 0 maintenance
CAP-2
Number of Air-to-Ground (A/G) radios
13
CAP-3
Number of Ground-to-Ground (G/G) Lines (to include Land Mobile Radio)
15
CAP-4
Number of A/G Radios per Position
13
CAP-5
Number of G/G lines per Position
15

2.15. ENVIRONMENTAL, SAFETY and OPERATIONAL HEALTH REQUIREMENTS

Table 2.15

Number
Description
Requirement
ENV-1
HAZMAT
The use of toxic chemicals, hazardous substances, or ozone depleting chemicals (ODCs) shall be avoided, whenever feasible. EPA Title III, List of Lists, EPA 550-B-21-001, provides a listing of toxic chemicals to be avoided.
ENV-2
MSDS
The supplier shall provide copies of Material Safety Data Sheets (MSDS) for all hazardous or toxic materials being supplied at least 120 days prior to the first delivery.
ENV-3
Preferred Materials
Recycled, recovered, or environmentally preferable materials shall be used to the maximum extent possible provided that the material meets or exceeds the operational and maintenance requirements, and promotes economically advantageous life cycle costs.
ENV-4
OSHA
System shall comply with all OSHA requirements per AFMAN 91-203.
ENV-5
NFPA-70 (NEC)
All electrical systems shall comply with the National Electrical Code (NEC).
ENV-6
Grounding Protection
System shall meet the requirements of MIL-STD- 188-124B for grounding, bonding, and shielding though the government will be responsible for providing the appropriate facility grounding termination point for the delivered systems.
ENV-7
Static protection
System shall meet the requirements of NFPA-77 for static electricity.
ENV-8
System Safety
System shall meet the requirements of MIL-STD-882E, Section 4.
ENV-9
Internal Chassis Ground
A ground terminal or equivalent function shall be provided on all subsystems within the equipment. The ground terminal shall be located on the input power connector or on the equipment terminal board and shall connect to the internal chassis by means of conductors at least equal in size to one of the power input conductors. Safety grounding within the equipment shall terminate on the ground terminal. Grounds and AC return lines shall be separated.
ENV-10
External Chassis Ground
A ground conductor shall be included with the system power conductors and shall connect to the ground terminal of individual units when power is routed externally between individual units of the equipment.
ENV-11
Safety Shielding
System protective shields shall be provided to protect personnel from accidental contact with parts in excess of 30V RMS or 30V DC during operation or maintenance actions.
ENV-12
Human Factors
VCS shall comply with HF-STD-001B FAA Human Factors Design Standard dated 12/30/2016.
ENV-13
Human Factors
VCS shall comply with the latest version of human factors IAW MIL-STD-1472.
ENV-14
MOPP Gear
Touch Entry Devices shall be capable of being activated and fully utilized while the operator is in Mission Oriented Protective Posture (MOPP) Gear Level 4.

2.16. CYBERSECURITY REQUIREMENTS

Table 2.16

Number
Description
Requirement

CYB-1

(KPP)

Operating System
The operating system for all computers shall be fully compatible and required to run on the current Security Technical Implementation Guide (STIG) version from Defense Information Systems Agency’s (DISA).
CYB-2
Highly Secure