Attachment_7_Equipment_list.pdf

PDF 69 KB Posted

Attached to
Data Center Reconfiguration Federal contract opportunity
Solicitation number
FA7014-15-T3002
Issued by
Department of the Air Force Headquarters District Washington

About this file

New Equipment List

View the file

Other files for this federal contract opportunity

Other files attached to Data Center Reconfiguration, newest first.
File Type Posted
Attachment_8_Schematic_2.pdf PDF
Equipment_List_Amendment_2.docx DOCX document
Attachment_10_Schematic_3.pdf PDF
Attachment_1_SOW_Data_Center_Amendment_2.docx DOCX document
Attachment_9_Schematic_1.pdf PDF
Attachment_2_QASP_Data_Center.pdf PDF
Attachment_1_SOW_Data_Center.pdf PDF
Solicitation.pdf PDF
Attachment_4_Eval_Method_V2.pdf PDF
Attachment_8_JBA_Entire_CSR_Power.pdf PDF
Attachment_10_JBA_SCE_Power.pdf PDF
Attachment_9_JBA_Entire_CSR_View.pdf PDF
Amendment_1_Q A.docx DOCX document
Attachment_4_Eval_Method_Amendment_1.pdf PDF
Attachment_4_Eval_Method.pdf PDF
Attachment_2_QASP_Data_Center.pdf PDF
Attachment_9_Materials_List.pdf PDF
Attachment_5_Past_Performance_Information_Sheet.pdf PDF
Attachment_6__Cost_ _Price__Worksheet.xls XLS spreadsheet
Attachment_7_SCE_Data_Center.pdf PDF
Attachment_8_SCE_Data_Center_TO_BE.pdf PDF
Attachment_3_Justification_and_Approval_(Signed).pdf PDF
Attachment_1_SOW_Data_Center.pdf PDF
Solicitation_FA7014-15-T-3002.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Quantity Item Description 36 AP8865 Rack PDU 2G, Metered, ZeroU, 8.6kW, 208V, (36) C13 & (6) C19 & (2) 5-20 8 AP7516 Rack PDU, Basic, 1U, 14.4kW, 208V, (6) C19 2 AR8560 Cable Trough, Open Bottom, 600mm 2 AR8162ABLK Data Cable Partition, NetShelter, 600mm Wide

1 PSX-PDU120V 120 V TYPE PDU

1 ELECTRICAL SYSTEM 120V -ELECTRICAL SYSTEM 120V

1 0G-PDPB150G6FATO - -ASSY 84P PDU BASE UNIT ATO

1 DISTRIBUTION BREAKERS 120V -TYPE & AMP OF DISTRIBUTION CKT BRKS

18 0M-5366 - -S/A TESTED BRKR 3P 30A PNL

8 0M-6866 - -S/A TESTED 3P 50A CKT BRKR 120/240 UL

1 OPTIONS & ACCESSORIES 120V -OPTIONS AND ACCESSORIES

6 0G-8310 - -KIT FILLER SQD NQ PNL QTY 15 ATO

17 0G-8313 - -PLUG FILLER GLAND PLATE 84P PDU ATO

1 RACK COLOR -RACK COLOR

1 0G-8315 - -ASSY PACKAGING FINAL 84P PDU ATO

1 PSX-PDU120V 120 V TYPE PDU

1 ELECTRICAL SYSTEM 120V -ELECTRICAL SYSTEM 120V

1 0G-PDPB150G6FATO - -ASSY 84P PDU BASE UNIT ATO

1 DISTRIBUTION BREAKERS 120V -TYPE & AMP OF DISTRIBUTION CKT BRKS

18 0M-5366 - -S/A TESTED BRKR 3P 30A PNL

8 0M-6866 - -S/A TESTED 3P 50A CKT BRKR 120/240 UL

1 OPTIONS & ACCESSORIES 120V -OPTIONS AND ACCESSORIES

6 0G-8310 - -KIT FILLER SQD NQ PNL QTY 15 ATO

17 0G-8313 - -PLUG FILLER GLAND PLATE 84P PDU ATO

1 RACK COLOR -RACK COLOR

1 0G-8315 - -ASSY PACKAGING FINAL 84P PDU ATO

2 WSTRTUP5X8-PD-50 Start-Up Service 5X8 for (1) InfraStruxure 60kVA / 150kVA PDU 1 WSITECOORD Site Coordination Service 2 WASSEMUPS5X8-PX-21 Scheduled 5X8 Assembly Service for Symmetra PX 40 kW UPS and/or PDU

Electrical Installation by Schneider Electric Installation Team with the following

SOW:

Below bill of materials must be purchased as a single solution to avoid on-site installation complications

- Shut down and remove two existing 80kPDU from main room computer room.

- Receive and unpack all new equipment listed above

-Remove all whips from existing PDU's and from existing cabinets in Glass Wall room

- Install new 150kW PDU Cabinets into customer dedicated spaces

- Run new feeds from previous 80kW PDU's into Row C of glass wall room

- Provide and install 36 - new 208v 3phase 30 amp feeds to customer designated cabinets in glass wall room from new 150kW PDU's.

- Provide and install 16 - new 208v 3phase 30 amp feeds to customer designated cabinets in glass wall room from new 150kW PDU's.

- Remove and dispose of existing sub panel C in main computer room

-Install 42 Pole 208v 3Phase panel in Glass wall room including new feeds from existing

UPS panel

- Move all glass room cooling feeds to newly installed panel C

- Provide Project Management, and coordination between Customers representative, APC Factory Electrical Contractor, Freight Company and APC certified service technician to insure a successful completion of the Project.

Mechanical Installation by Schneider Electric Installation Team with the following SOW:

- Shut down and move customers four existing ACRC100 In Row Cooling units from main computer room to glass wall room row C

- Disconnect and drain supply lines of each of the ACRC100 Units from existing Cooling

Distribution units

- Run new insulated PEX lines from CDU units to new ACRC100 locations in Glass Wall

Room

-Provide and install new condensate lines from the cooling units to the condensate pump

- Provide and install ( 4 ) overhead power whips to provide power to the existing cooling units in their new locations

- Provide Project Management, and coordination between Customers representative, APC Factory Electrical Contractor, Freight Company and APC certified service technician to insure a successful completion of the Project.

1 QWINSTALL-QBED69929

QWINSTALL-QBED695661