Attch_2_Bid_Schedule.pdf
PDF 261 KB Posted
- Attached to
- Glass Replacement Federal contract opportunity
- Solicitation number
- FA7000-16-R-0005
About this file
Bid Schedule
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Questions__Responses-Site_Visit_09_Aug_16.pdf | ||
| Attachment_1_Statement_of_Work_Revised_18_Aug_16.pdf | ||
| Attachment_3_Davis-Bacon_Wage_Determination_07.29.2016.pdf | ||
| Attachment_2_Bid_Schedules_Revised_18_Aug_16.pdf | ||
| FA7000-16-R-0005-0001.pdf | ||
| Site_Visit_Slides_Glass_Replacement_IDIQ_09_Aug_16_FBO_Post.pdf | ||
| Site_Visit_Attendee_Log_09_Aug_16_FBO_Post.pdf | ||
| Site_Visit_Minutes_09_Aug_16_FBO_post.pdf | ||
| Attch_1_SOW_Glass_Replacment_July_2016.pdf | ||
| Attch_3_Davis_Bacon_07-01-2016.pdf | ||
| Attch_4_-_Past_Performance_Questionnaire07-18-2016.rtf | RTF text file | |
| FA7000-16-R-0005.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BID SCHEDULE
BASIC YEAR
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform the following work in accordance with contract specifications.
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
0001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed
0001A At Ground Level 100 SF $ $ ________ 0001B Above Ground Level 100 SF $ $_________
0002 1/4” Tempered Float Glass, Set to Match Existing with Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied
0002A At Ground Level 500 SF $_______ $________ 0002B Above Ground Level 500 SF $_______ $_________
0003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied
0003A At Ground Level 1,750 SF $_____ $________ 0003B Above Ground Level 1,750 SF $_____ $________
NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line item. They can be set from the building interior without the use of ladders or scaffolding.
0004 1” Clear Tempered (Insulated Glass) Set with Elastomer Type Sealing Compound, Pneumatically Applied
0004A At Ground Level 250 SF $______ $________ 0004B Above Ground Level 250 SF $______ $________
0005 1” Heat Absorbing Unit, Tempered
0005A At Ground Level 100 SF $_____ $_______ 0005B Above Ground Level 100 SF $_____ $_______
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
0006 3/8” Heat Absorbing, Glare Reducing, Tempered
0006A At Ground Level 60 SF $_____ $________ 0006B Above Ground Level 60 SF $_____ $________
0007 1/8” Rolled Glass, Type III, Set with Glazing Compound, Face Glazed (Heat Plant)
0007A At Ground Level 300 SF $_____ $________ 0007B Above Ground Level 300 SF $_____ $________
0008 Seedy, Cathedral Type, Set with Neoprene Stripe, Black Glazing Clips and Black Glazing Compound
0008A At Ground Level 100 SF $_____ $________ 0008B Above Ground Level 100 SF $_____ $________
0009 1/4” Laminated Glass, DS/DS, 2 Parts, 11% Gray
0009A At Ground Level 100 SF $_____ $________ 0009B Above Ground Level 100 SF $_____ $________
NOTE: Items 0008 and 0009 pertain to the Cadet Chapel, Building 2306.
0010 1/4” Heat Absorbing and Glare Reducing, Set with Glazing Compound
0010A At Ground Level 50 SF $_____ $_______ 0010B Above Ground Level 50 SF $_____ $_______
0011 Porcelain Enamel Panels, “Mirawal” Set with Elastomer Sealing Compound Pneumatically Applied. Color to Match Existing – Gray or Black
0011A At Ground Level 100 SF $_____ $_________ 0011B Above Ground Level 100 SF $_____ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
0012 Recaulk Existing Glass
0012A At Ground Level 500 LF $______ $_________ 0012B Above Ground Level 500 LF $______ $_________
0013 Mirror, Copper Coated
0013A At Ground Level 250 SF $______ $_________ 0013B Above Ground Level 250 SF $______ $_________
0014 1/4” Wire Glass
0014A At Ground Level 50 SF $______ $_________ 0014B Above Ground Level 50 SF $______ $_________
0015 1” Clear Tempered Glass, Insulated Units
0015A At Ground Level 50 SF $______ $_________ 0015B Above Ground Level 50 SF $______ $_________
0016 1” Tinted Tempered Glass, Insulated Units
0016A At Ground Level 50 SF $______ $_________ 0016B Above Ground Level 50 SF $______ $_________
0017 1” Low coating Grey Herculite Glass door With polished edges
0017A At Ground Level 100 SF $______ $_________ 0017B Above Ground Level 100 SF $______ $_________
0018 1” Blast Resistant Unit Temped/Laminated
0018A At Ground Level 100 SF $______ $_________ 0018B Above Ground Level 100 SF $______ $_________
0019 1” DOD Blast resistant
0019A At Ground Level 100 SF $______ $_________ 0019B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
0020 3/16 Mirror With !/2 Bevel
0020A At Ground Level 100 SF $_______ $_________ 0020B Above Ground Level 100 SF $_______ $_________
0021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT
0021A At Ground Level 100 SF $______ $_________ 0021B Above Ground Level 100 SF $______ $_________
0022 1” Ve3=2M Special product coating Gray Blast Make-up
0022A At Ground Level 100 SF $______ $_________ 0022B Above Ground Level 100 SF $______ $_________
0023 1” Temp over temp laminated insulated unit, Gray blast make-up
0023A At Ground Level 100 SF $_______ $_________ 0023B Above Ground Level 100 SF $_______ $_________
0024 1” Viracon low-E insulated unit
0024A At Ground Level 100 SF $_______ $_________ 0024B Above Ground Level 100 SF $_______ $_________
0025 1” VE-3-2M Gray low coating
0025A At Ground Level 100 SF $_______ $_________ 0025B Above Ground Level 100 SF $_______ $_________
0026 1” laminated / tempered gray with special low-e coating
0025A At Ground Level 100 SF $_______ $_________ 0025B Above Ground Level 100 SF $_______ $_________
0026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap
0026A At Ground Level 100 SF $______ $_________ 0026B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform the following work in accordance with contract specifications
0027 1” Viracon VE3-2M, 1 inch special gray with low-e coating, both lights safety black spacer
0027A At Ground Level 100 SF $______ $_________ 0027B Above Ground Level 100 SF $______ $_________
0028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat
0028A At Ground Level 100 SF $_______ $_________ 0028B Above Ground Level 100 SF $_______ $_________
0029 1” Special tempered, Laminated Blast unit
0029A At Ground Level 100 SF $_______ $_________ 0029B Above Ground Level 100 SF $_______ $_________
0030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer
0030A At Ground Level 100 SF $_______ $_________ 0030B Above Ground Level 100 SF $_______ $_________
0031 1” Clear tempered insulated unit with low-e special coating
0031A At Ground Level 100 SF $_______ $_________ 0031B Above Ground Level 100 SF $_______ $_________
0032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer
0032A At Ground Level 100 SF $_______ $_________ 0032B Above Ground Level 100 SF $_______ $_________
00330 1” Reduce heat transfer glass tinted with blast damage safety film
0033A At Ground Level 100 SF $_______ $_________ 0033B Above Ground Level 100 SF $_______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
0034 5/8” Laminated glass with .015” thick daylight insulation
0034A At Ground Level 100 SF $_______ $_________ 0034B Above Ground Level 100 SF $_______ $_________
0035 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated
0035A At Ground Level 100 SF $_______ $_________ 0035B Above Ground Level 100 SF $_______ $_________
0036 ¼” Lexan MR4000
0036A At Ground Level 5 SF $________ $_________ 0036B Above Ground Level 5 SF $________ $_________
0037 1/8” Plexiglas
0037A At Ground Level 5 SF $_______ $_________ 0037B Above Ground Level 5 SF $_______ $_________
0038 ¼” Plexiglas
0038A At Ground Level 5 SF $______ $_______ 0038B Above Ground Level 5 SF $______ $_______
0039 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops
0039A At Ground Level 5 SF $_______ $_________ 0039B Above Ground Level 5 SF $_______ $_________
0040 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered
0040A At Ground Level 5 SF $ $_________ 0040B Above Ground Level 5 SF $ $_________
NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of Fairchild Hall, Building 2354.
BASIC YEAR TOTAL $________
0041 Non-Pre-Priced Items (Non-Biddable Item)
Include overhead and profit in unit and extended amount. DO NOT include bonding cost on the bid schedule.
1ST OPTION YEAR
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
1001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed
1001A At Ground Level 100 SF $ $ ________ 1001B Above Ground Level 100 SF $ $_________
1002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied
1002A At Ground Level 500 SF $_______ $________ 1002B Above Ground Level 500 SF $_______ $_________
1003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied
1003A At Ground Level 1,750 SF $_____ $________ 1003B Above Ground Level 1,750 SF $_____ $________
NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line
1004 1” Clear Tempered (Insulated Glass)
Compound, Pneumatically Applied
1004A At Ground Level 250 SF $______ $________ 1004B Above Ground Level 250 SF $______ $________
1005 1” Heat Absorbing Unit, Tempered
1005A At Ground Level 100 SF $_____ $_______ 1005B Above Ground Level 100 SF $_____ $_______
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
1006 3/8” Heat Absorbing, Glare Reducing, Tempered
1006A At Ground Level 60 SF $_____ $________ 1006B Above Ground Level 60 SF $_____ $________
1007 1/8” Rolled Glass, Type III, Set with
(Heat Plant)
1007A At Ground Level 300 SF $_____ $________ 1007B Above Ground Level 300 SF $_____ $________
1008 Seedy, Cathedral Type, Set with
Clips and Black Glazing Compound
1008A At Ground Level 100 SF $_____ $________ 1008B Above Ground Level 100 SF $_____ $________
1009 1/4” Laminated Glass, DS/DS, 1009A At Ground Level 100 SF $_____ $________ 1009B Above Ground Level 100 SF $_____ $________
1010 1/4” Heat Absorbing and Glare
1010A At Ground Level 50 SF $_____ $_______ 1010B Above Ground Level 50 SF $_____ $_______
1011 Porcelain Enamel Panels, “Mirawal”
Pneumatically Applied. Color to Match Existing – Gray or Black
1011A At Ground Level 100 SF $_____ $_________ 1011B Above Ground Level 100 SF $_____ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
1012 Recaulk Existing Glass
1012A At Ground Level 500 LF $______ $_________ 1012B Above Ground Level 500 LF $______ $_________
1013 Mirror, Copper Coated
1013A At Ground Level 250 SF $______ $_________ 1013B Above Ground Level 250 SF $______ $_________
1014 1/4” Wire Glass
1014A At Ground Level 50 SF $______ $_________ 1014B Above Ground Level 50 SF $______ $_________
1015 1” Clear Tempered Glass, Insulated Units
1015A At Ground Level 50 SF $______ $_________ 1015B Above Ground Level 50 SF $______ $_________
1016 1” Tinted Tempered Glass, Insulated Units
1016A At Ground Level 50 SF $______ $_________ 1016B Above Ground Level 50 SF $______ $_________
1017 1” Low coating Grey Herculite Glass door With polished edges
1017A At Ground Level 100 SF $______ $_________ 1017B Above Ground Level 100 SF $______ $_________
1018 1” Blast Resistant Unit Temped/Laminated
1018A At Ground Level 100 SF $______ $_________ 1018B Above Ground Level 100 SF $______ $_________
1019 1” DOD Blast resistant
1019A At Ground Level 100 SF $______ $_________ 1019B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
1020 3/16 Mirror With !/2 Bevel
1020A At Ground Level 100 SF $_______ $_________ 1020B Above Ground Level 100 SF $_______ $_________
1021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT
1021A At Ground Level 100 SF $______ $_________ 1021B Above Ground Level 100 SF $______ $_________
1022 1” Ve3=2M Special product coating Gray Blast Make-up
1022A At Ground Level 100 SF $______ $_________ 1022B Above Ground Level 100 SF $______ $_________
1023 1” Temp over temp laminated insulated unit, Gray blast make-up
1023A At Ground Level 100 SF $_______ $_________ 1023B Above Ground Level 100 SF $_______ $_________
1024 1” Viracon low-E insulated unit
1024A At Ground Level 100 SF $_______ $_________ 1024B Above Ground Level 100 SF $_______ $_________
1025 1” VE-3-2M Gray low coating
1025A At Ground Level 100 SF $_______ $_________ 1025B Above Ground Level 100 SF $_______ $_________
1026 1” laminated / tempered gray with special low-e coating
1025A At Ground Level 100 SF $_______ $_________ 1025B Above Ground Level 100 SF $_______ $_________
1026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap
1026A At Ground Level 100 SF $______ $_________ 1026B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
1027 1” Viracon VE3-2M, 1 inch special gray with spacer
1027A At Ground Level 100 SF $______ $_________ 1027B Above Ground Level 100 SF $______ $_________
1028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat
1028A At Ground Level 100 SF $_______ $_________ 1028B Above Ground Level 100 SF $_______ $_________
1029 1” Special tempered, Laminated Blast unit
1029A At Ground Level 100 SF $_______ $_________ 1029B Above Ground Level 100 SF $_______ $_________
1030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer
1030A At Ground Level 100 SF $_______ $_________ 1030B Above Ground Level 100 SF $_______ $_________
1031 1” Clear tempered insulated unit with low-e special coating
1031A At Ground Level 100 SF $_______ $_________ 1031B Above Ground Level 100 SF $_______ $_________
1032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer
1032A At Ground Level 100 SF $_______ $_________ 1032B Above Ground Level 100 SF $_______ $_________
10330 1” Reduce heat transfer glass tinted with blast damage safety film
1033A At Ground Level 100 SF $_______ $_________ 1033B Above Ground Level 100 SF $_______ $_________
1st OPTION YEAR
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
1034 5/8” Laminated glass with .015” thick daylight insulation
1034A At Ground Level 100 SF $_______ $_________ 1034B Above Ground Level 100 SF $_______ $_________
1035 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated
1035A At Ground Level 100 SF $_______ $_________ 1035B Above Ground Level 100 SF $_______ $_________
1036 ¼” Lexan MR4000
1036A At Ground Level 5 SF $________ $_________ 1036B Above Ground Level 5 SF $________ $_________
1037 1/8” Plexiglas
1037A At Ground Level 5 SF $_______ $_________ 1037B Above Ground Level 5 SF $_______ $_________
1038 ¼” Plexiglas
1038A At Ground Level 5 SF $______ $________ 1038B Above Ground Level 5 SF $______ $________
1039 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops
1039A At Ground Level 5 SF $_______ $_________ 1039B Above Ground Level 5 SF $_______ $_________
1040 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered
1040A At Ground Level 5 SF $ $_________ 1040B Above Ground Level 5 SF $ $_________
NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of
1st OPTION YEAR TOTAL $________
1041 Non-Pre-Priced Items (Non-Biddable Item)
2nd OPTION YEAR
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
2001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed
2001A At Ground Level 100 SF $ $ ________ 2001B Above Ground Level 100 SF $ $_________
2002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied
2002A At Ground Level 500 SF $_______ $________ 2002B Above Ground Level 500 SF $_______ $_________
2003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied
2003A At Ground Level 1,750 SF $_____ $________ 2003B Above Ground Level 1,750 SF $_____ $________
NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line
2004 1” Clear Tempered (Insulated Glass)
Compound, Pneumatically Applied
2004A At Ground Level 250 SF $______ $________ 2004B Above Ground Level 250 SF $______ $________
2005 1” Heat Absorbing Unit, Tempered
2005A At Ground Level 100 SF $_____ $_______ 2005B Above Ground Level 100 SF $_____ $_______
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
2006 3/8” Heat Absorbing, Glare Reducing, Tempered
2006A At Ground Level 60 SF $_____ $________ 2006B Above Ground Level 60 SF $_____ $________
2007 1/8” Rolled Glass, Type III, Set with
(Heat Plant)
2007A At Ground Level 300 SF $_____ $________ 2007B Above Ground Level 300 SF $_____ $________
2008 Seedy, Cathedral Type, Set with
Clips and Black Glazing Compound
2008A At Ground Level 100 SF $_____ $________ 2008B Above Ground Level 100 SF $_____ $________
2009 1/4” Laminated Glass, DS/DS, 2009A At Ground Level 100 SF $_____ $________ 2009B Above Ground Level 100 SF $_____ $________
2010 1/4” Heat Absorbing and Glare
2010A At Ground Level 50 SF $_____ $_______ 2010B Above Ground Level 50 SF $_____ $_______
2011 Porcelain Enamel Panels, “Mirawal”
Pneumatically Applied. Color to Match Existing – Gray or Black
2011A At Ground Level 100 SF $_____ $_________ 2011B Above Ground Level 100 SF $_____ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
2012 Recaulk Existing Glass
2012A At Ground Level 500 LF $______ $_________ 2012B Above Ground Level 500 LF $______ $_________
2013 Mirror, Copper Coated
2013A At Ground Level 250 SF $______ $_________ 2013B Above Ground Level 250 SF $______ $_________
2014 1/4” Wire Glass
2014A At Ground Level 50 SF $______ $_________ 2014B Above Ground Level 50 SF $______ $_________
2015 1” Clear Tempered Glass, Insulated Units
2015A At Ground Level 50 SF $______ $_________ 2015B Above Ground Level 50 SF $______ $_________
2016 1” Tinted Tempered Glass, Insulated Units
2016A At Ground Level 50 SF $______ $_________ 2016B Above Ground Level 50 SF $______ $_________
2017 1” Low coating Grey Herculite Glass door With polished edges
2017A At Ground Level 100 SF $______ $_________ 2017B Above Ground Level 100 SF $______ $_________
2018 1” Blast Resistant Unit Temped/Laminated
2018A At Ground Level 100 SF $______ $_________ 2018B Above Ground Level 100 SF $______ $_________
2019 1” DOD Blast resistant
2019A At Ground Level 100 SF $______ $_________ 2019B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
2020 3/16 Mirror With !/2 Bevel
2020A At Ground Level 100 SF $_______ $_________ 2020B Above Ground Level 100 SF $_______ $_________
2021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT
2021A At Ground Level 100 SF $______ $_________ 2021B Above Ground Level 100 SF $______ $_________
2022 1” Ve3=2M Special product coating Gray Blast Make-up
2022A At Ground Level 100 SF $______ $_________ 2022B Above Ground Level 100 SF $______ $_________
2023 1” Temp over temp laminated insulated unit, Gray blast make-up
2023A At Ground Level 100 SF $_______ $_________ 2023B Above Ground Level 100 SF $_______ $_________
2024 1” Viracon low-E insulated unit
2024A At Ground Level 100 SF $_______ $_________ 2024B Above Ground Level 100 SF $_______ $_________
2025 1” VE-3-2M Gray low coating
2025A At Ground Level 100 SF $_______ $_________ 2025B Above Ground Level 100 SF $_______ $_________
2026 1” laminated / tempered gray with special low-e coating
2025A At Ground Level 100 SF $_______ $_________ 2025B Above Ground Level 100 SF $_______ $_________
2026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap
2026A At Ground Level 100 SF $______ $_________ 2026B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform the following work in accordance with contract specifications
2027 1” Viracon VE3-2M, 1 inch special gray with spacer
2027A At Ground Level 100 SF $______ $_________ 2027B Above Ground Level 100 SF $______ $_________
2028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat
2028A At Ground Level 100 SF $_______ $_________ 2028B Above Ground Level 100 SF $_______ $_________
2029 1” Special tempered, Laminated Blast unit
2029A At Ground Level 100 SF $_______ $_________ 2029B Above Ground Level 100 SF $_______ $_________
2030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer
2030A At Ground Level 100 SF $_______ $_________ 2030B Above Ground Level 100 SF $_______ $_________
2031 1” Clear tempered insulated unit with low-e special coating
2031A At Ground Level 100 SF $_______ $_________ 2031B Above Ground Level 100 SF $_______ $_________
2032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer
2032A At Ground Level 100 SF $_______ $_________ 2032B Above Ground Level 100 SF $_______ $_________
20330 1” Reduce heat transfer glass tinted with blast damage safety film
2033A At Ground Level 100 SF $_______ $_________ 2033B Above Ground Level 100 SF $_______ $_________
2040 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered
2040A At Ground Level 5 SF $ $_________ 2040B Above Ground Level 5 SF $ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
2034 5/8” Laminated glass with .015” thick daylight insulation
2034A At Ground Level 100 SF $_______ $_________ 2034B Above Ground Level 100 SF $_______ $_________
2035 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated
2035A At Ground Level 100 SF $_______ $_________ 2035B Above Ground Level 100 SF $_______ $_________
2036 ¼” Lexan MR4000
2036A At Ground Level 5 SF $________ $_________ 2036B Above Ground Level 5 SF $________ $_________
2037 1/8” Plexiglas
2037A At Ground Level 5 SF $_______ $_________ 2037B Above Ground Level 5 SF $_______ $_________
2038 ¼” Plexiglas
2038A At Ground Level 5 SF $______ $________ 2038B Above Ground Level 5 SF $______ $________
2039 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops
2039A At Ground Level 5 SF $_______ $_________ 2039B Above Ground Level 5 SF $_______ $_________
2040 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered
2040A At Ground Level 5 SF $ $_________ 2040B Above Ground Level 5 SF $ $_________
NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of
2nd OPTION YEAR TOTAL $________
2041 Non-Pre-Priced Items (Non-Biddable Item)
3rd OPTION YEAR
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
3001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed
3001A At Ground Level 100 SF $ $ ________ 3001B Above Ground Level 100 SF $ $_________
3002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied
3002A At Ground Level 500 SF $_______ $________ 3002B Above Ground Level 500 SF $_______ $_________
3003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied
3003A At Ground Level 1,750 SF $_____ $________ 3003B Above Ground Level 1,750 SF $_____ $________
NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line
3004 1” Clear Tempered (Insulated Glass)
Compound, Pneumatically Applied
3004A At Ground Level 250 SF $______ $________ 3004B Above Ground Level 250 SF $______ $________
3005 1” Heat Absorbing Unit, Tempered
3005A At Ground Level 100 SF $_____ $_______ 3005B Above Ground Level 100 SF $_____ $_______
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
3006 3/8” Heat Absorbing, Glare Reducing, Tempered
3006A At Ground Level 60 SF $_____ $________ 3006B Above Ground Level 60 SF $_____ $________
3007 1/8” Rolled Glass, Type III, Set with
(Heat Plant)
3007A At Ground Level 300 SF $_____ $________ 3007B Above Ground Level 300 SF $_____ $________
3008 Seedy, Cathedral Type, Set with
Clips and Black Glazing Compound
3008A At Ground Level 100 SF $_____ $________ 3008B Above Ground Level 100 SF $_____ $________
3009 1/4” Laminated Glass, DS/DS, 3009A At Ground Level 100 SF $_____ $________ 3009B Above Ground Level 100 SF $_____ $________
3010 1/4” Heat Absorbing and Glare
3010A At Ground Level 50 SF $_____ $_______ 3010B Above Ground Level 50 SF $_____ $_______
3011 Porcelain Enamel Panels, “Mirawal”
Pneumatically Applied. Color to Match Existing – Gray or Black
3011A At Ground Level 100 SF $_____ $_________ 3011B Above Ground Level 100 SF $_____ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
3012 Recaulk Existing Glass
3012A At Ground Level 500 LF $______ $_________ 3012B Above Ground Level 500 LF $______ $_________
3013 Mirror, Copper Coated
3013A At Ground Level 250 SF $______ $_________ 3013B Above Ground Level 250 SF $______ $_________
3014 1/4” Wire Glass
3014A At Ground Level 50 SF $______ $_________ 3014B Above Ground Level 50 SF $______ $_________
3015 1” Clear Tempered Glass, Insulated Units
3015A At Ground Level 50 SF $______ $_________ 3015B Above Ground Level 50 SF $______ $_________
3016 1” Tinted Tempered Glass, Insulated Units
3016A At Ground Level 50 SF $______ $_________ 3016B Above Ground Level 50 SF $______ $_________
3017 1” Low coating Grey Herculite Glass door With polished edges
3017A At Ground Level 100 SF $______ $_________ 3017B Above Ground Level 100 SF $______ $_________
3018 1” Blast Resistant Unit Temped/Laminated
3018A At Ground Level 100 SF $______ $_________ 3018B Above Ground Level 100 SF $______ $_________
3019 1” DOD Blast resistant
3019A At Ground Level 100 SF $______ $_________ 3019B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
3020 3/16 Mirror With !/2 Bevel
3020A At Ground Level 100 SF $_______ $_________ 3020B Above Ground Level 100 SF $_______ $_________
3021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT
3021A At Ground Level 100 SF $______ $_________ 3021B Above Ground Level 100 SF $______ $_________
3022 1” Ve3=2M Special product coating Gray Blast Make-up
3022A At Ground Level 100 SF $______ $_________ 3022B Above Ground Level 100 SF $______ $_________
3023 1” Temp over temp laminated insulated unit, Gray blast make-up
3023A At Ground Level 100 SF $_______ $_________ 3023B Above Ground Level 100 SF $_______ $_________
3024 1” Viracon low-E insulated unit
3024A At Ground Level 100 SF $_______ $_________ 3024B Above Ground Level 100 SF $_______ $_________
3025 1” VE-3-2M Gray low coating
3025A At Ground Level 100 SF $_______ $_________ 3025B Above Ground Level 100 SF $_______ $_________
3026 1” laminated / tempered gray with special low-e coating
3025A At Ground Level 100 SF $_______ $_________ 3025B Above Ground Level 100 SF $_______ $_________
3026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap
3026A At Ground Level 100 SF $______ $_________ 3026B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
3027 1” Viracon VE3-2M, 1 inch special gray with spacer
3027A At Ground Level 100 SF $______ $_________ 3027B Above Ground Level 100 SF $______ $_________
3028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat
3028A At Ground Level 100 SF $_______ $_________ 3028B Above Ground Level 100 SF $_______ $_________
3029 1” Special tempered, Laminated Blast unit
3029A At Ground Level 100 SF $_______ $_________ 3029B Above Ground Level 100 SF $_______ $_________
3030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer
3030A At Ground Level 100 SF $_______ $_________ 3030B Above Ground Level 100 SF $_______ $_________
3031 1” Clear tempered insulated unit with low-e special coating
3031A At Ground Level 100 SF $_______ $_________ 3031B Above Ground Level 100 SF $_______ $_________
3032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer
3032A At Ground Level 100 SF $_______ $_________ 3032B Above Ground Level 100 SF $_______ $_________
30330 1” Reduce heat transfer glass tinted with blast damage safety film
3033A At Ground Level 100 SF $_______ $_________ 3033B Above Ground Level 100 SF $_______ $_________
3RD OPTION YEAR
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
3034 5/8” Laminated glass with .015” thick daylight insulation
3034A At Ground Level 100 SF $_______ $_________ 3034B Above Ground Level 100 SF $_______ $_________
3035 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated
3035A At Ground Level 100 SF $_______ $_________ 3035B Above Ground Level 100 SF $_______ $_________
3036 ¼” Lexan MR4000
3036A At Ground Level 5 SF $________ $_________ 3036B Above Ground Level 5 SF $________ $_________
3037 1/8” Plexiglas
3037A At Ground Level 5 SF $_______ $_________ 3037B Above Ground Level 5 SF $_______ $_________
3038 ¼” Plexiglas
3038A At Ground Level 5 SF $______ $_________ 3038B Above Ground Level 5 SF $______ $_________ 3039 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops
3039A At Ground Level 5 SF $_______ $_________ 3039B Above Ground Level 5 SF $_______ $_________
3040 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered
3040A At Ground Level 5 SF $ $_________ 3040B Above Ground Level 5 SF $ $_________
NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of
3rd OPTION YEAR TOTAL $________
3041 Non-Pre-Priced Items (Non-Biddable Item)
4Th OPTION YEAR
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
4001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed
4001A At Ground Level 100 SF $ $ ________ 4001B Above Ground Level 100 SF $ $_________
4002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied
4002A At Ground Level 500 SF $_______ $________ 4002B Above Ground Level 500 SF $_______ $_________
4003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied
4003A At Ground Level 1,750 SF $_____ $________ 4003B Above Ground Level 1,750 SF $_____ $________
NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line
4004 1” Clear Tempered (Insulated Glass)
Compound, Pneumatically Applied
4004A At Ground Level 250 SF $______ $________ 4004B Above Ground Level 250 SF $______ $________
4005 1” Heat Absorbing Unit, Tempered
4005A At Ground Level 100 SF $_____ $_______ 4005B Above Ground Level 100 SF $_____ $_______
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
EST UNIT EXTENDED
ITEM DESCRIPTION QTY UNIT PRICE AMOUNT
4006 3/8” Heat Absorbing, Glare Reducing, Tempered
4006A At Ground Level 60 SF $_____ $________ 4006B Above Ground Level 60 SF $_____ $________
4007 1/8” Rolled Glass, Type III, Set with
(Heat Plant)
4007A At Ground Level 300 SF $_____ $________ 4007B Above Ground Level 300 SF $_____ $________
4008 Seedy, Cathedral Type, Set with
Clips and Black Glazing Compound
4008A At Ground Level 100 SF $_____ $________ 4008B Above Ground Level 100 SF $_____ $________
4009 1/4” Laminated Glass, DS/DS, 4009A At Ground Level 100 SF $_____ $________ 4009B Above Ground Level 100 SF $_____ $________
4010 1/4” Heat Absorbing and Glare
4010A At Ground Level 50 SF $_____ $_______ 4010B Above Ground Level 50 SF $_____ $_______
4011 Porcelain Enamel Panels, “Mirawal”
Pneumatically Applied. Color to Match Existing – Gray or Black
4011A At Ground Level 100 SF $_____ $_________ 4011B Above Ground Level 100 SF $_____ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
4012 Recaulk Existing Glass
4012A At Ground Level 500 LF $______ $_________ 4012B Above Ground Level 500 LF $______ $_________
4013 Mirror, Copper Coated
4013A At Ground Level 250 SF $______ $_________ 4013B Above Ground Level 250 SF $______ $_________
4014 1/4” Wire Glass
4014A At Ground Level 50 SF $______ $_________ 4014B Above Ground Level 50 SF $______ $_________
4015 1” Clear Tempered Glass, Insulated Units
4015A At Ground Level 50 SF $______ $_________ 4015B Above Ground Level 50 SF $______ $_________
4016 1” Tinted Tempered Glass, Insulated Units
4016A At Ground Level 50 SF $______ $_________ 4016B Above Ground Level 50 SF $______ $_________
4017 1” Low coating Grey Herculite Glass door With polished edges
4017A At Ground Level 100 SF $______ $_________ 4017B Above Ground Level 100 SF $______ $_________
4018 1” Blast Resistant Unit Temped/Laminated
4018A At Ground Level 100 SF $______ $_________ 4018B Above Ground Level 100 SF $______ $_________
4019 1” DOD Blast resistant
4019A At Ground Level 100 SF $______ $_________ 4019B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
4020 3/16 Mirror With !/2 Bevel
4020A At Ground Level 100 SF $_______ $_________ 4020B Above Ground Level 100 SF $_______ $_________
4021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT
4021A At Ground Level 100 SF $______ $_________ 4021B Above Ground Level 100 SF $______ $_________
4022 1” Ve3=2M Special product coating Gray Blast Make-up
4022A At Ground Level 100 SF $______ $_________ 4022B Above Ground Level 100 SF $______ $_________
4023 1” Temp over temp laminated insulated unit, Gray blast make-up
4023A At Ground Level 100 SF $_______ $_________ 4023B Above Ground Level 100 SF $_______ $_________
4024 1” Viracon low-E insulated unit
4024A At Ground Level 100 SF $_______ $_________ 4024B Above Ground Level 100 SF $_______ $_________
4025 1” VE-3-2M Gray low coating
4025A At Ground Level 100 SF $_______ $_________ 4025B Above Ground Level 100 SF $_______ $_________
4026 1” laminated / tempered gray with special low-e coating
4025A At Ground Level 100 SF $_______ $_________ 4025B Above Ground Level 100 SF $_______ $_________
4026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap
4026A At Ground Level 100 SF $______ $_________ 4026B Above Ground Level 100 SF $______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
4027 1” Viracon VE3-2M, 1 inch special gray with spacer
4027A At Ground Level 100 SF $______ $_________ 4027B Above Ground Level 100 SF $______ $_________
4028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat
4028A At Ground Level 100 SF $_______ $_________ 4028B Above Ground Level 100 SF $_______ $_________
4029 1” Special tempered, Laminated Blast unit
4029A At Ground Level 100 SF $_______ $_________ 4029B Above Ground Level 100 SF $_______ $_________
4030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer
4030A At Ground Level 100 SF $_______ $_________ 4030B Above Ground Level 100 SF $_______ $_________
4031 1” Clear tempered insulated unit with low-e special coating
4031A At Ground Level 100 SF $_______ $_________ 4031B Above Ground Level 100 SF $_______ $_________
4032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer
4032A At Ground Level 100 SF $_______ $_________ 4032B Above Ground Level 100 SF $_______ $_________
40330 1” Reduce heat transfer glass tinted with blast damage safety film
4033A At Ground Level 100 SF $_______ $_________ 4033B Above Ground Level 100 SF $_______ $_________
The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform
4034 5/8” Laminated glass with .015” thick daylight insulation
4034A At Ground Level 100 SF $_______ $_________ 4034B Above Ground Level 100 SF $_______ $_________
4035 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated
4035A At Ground Level 100 SF $_______ $_________ 4035B Above Ground Level 100 SF $_______ $_________
4036 ¼” Lexan MR4000
4036A At Ground Level 5 SF $________ $_________ 4036B Above Ground Level 5 SF $________ $_________
4037 1/8” Plexiglas
4037A At Ground Level 5 SF $_______ $_________ 4037B Above Ground Level 5 SF $_______ $_________
4038 ¼” Plexiglas
4038A At Ground Level 5 SF $______ $_________ 4038B Above Ground Level 5 SF $______ $_________
4039 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops
4039A At Ground Level 5 SF $_______ $_________ 4039B Above Ground Level 5 SF $_______ $_________
4040 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered
4040A At Ground Level 5 SF $ $_________ 4040B Above Ground Level 5 SF $ $_________
NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of
4th OPTION YEAR TOTAL $________
4041 Non-Pre-Priced Items (Non-Biddable Item)
File details come from the government source that posted it. Updated .