BID SCHEDULE

BASIC YEAR

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform the following work in accordance with contract specifications.

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

0001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed

0001A At Ground Level 100 SF $ $ ________ 0001B Above Ground Level 100 SF $ $_________

0002 1/4” Tempered Float Glass, Set to Match Existing with Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied

0002A At Ground Level 500 SF $_______ $________ 0002B Above Ground Level 500 SF $_______ $_________

0003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied

0003A At Ground Level 1,750 SF $_____ $________ 0003B Above Ground Level 1,750 SF $_____ $________

NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line item. They can be set from the building interior without the use of ladders or scaffolding.

0004 1” Clear Tempered (Insulated Glass) Set with Elastomer Type Sealing Compound, Pneumatically Applied

0004A At Ground Level 250 SF $______ $________ 0004B Above Ground Level 250 SF $______ $________

0005 1” Heat Absorbing Unit, Tempered

0005A At Ground Level 100 SF $_____ $_______ 0005B Above Ground Level 100 SF $_____ $_______

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

0006 3/8” Heat Absorbing, Glare Reducing, Tempered

0006A At Ground Level 60 SF $_____ $________ 0006B Above Ground Level 60 SF $_____ $________

0007 1/8” Rolled Glass, Type III, Set with Glazing Compound, Face Glazed (Heat Plant)

0007A At Ground Level 300 SF $_____ $________ 0007B Above Ground Level 300 SF $_____ $________

0008 Seedy, Cathedral Type, Set with Neoprene Stripe, Black Glazing Clips and Black Glazing Compound

0008A At Ground Level 100 SF $_____ $________ 0008B Above Ground Level 100 SF $_____ $________

0009 1/4” Laminated Glass, DS/DS, 2 Parts, 11% Gray

0009A At Ground Level 100 SF $_____ $________ 0009B Above Ground Level 100 SF $_____ $________

NOTE: Items 0008 and 0009 pertain to the Cadet Chapel, Building 2306.

0010 1/4” Heat Absorbing and Glare Reducing, Set with Glazing Compound

0010A At Ground Level 50 SF $_____ $_______ 0010B Above Ground Level 50 SF $_____ $_______

0011 Porcelain Enamel Panels, “Mirawal” Set with Elastomer Sealing Compound Pneumatically Applied. Color to Match Existing – Gray or Black

0011A At Ground Level 100 SF $_____ $_________ 0011B Above Ground Level 100 SF $_____ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

0012 Recaulk Existing Glass

0012A At Ground Level 500 LF $______ $_________ 0012B Above Ground Level 500 LF $______ $_________

0013 Mirror, Copper Coated

0013A At Ground Level 250 SF $______ $_________ 0013B Above Ground Level 250 SF $______ $_________

0014 1/4” Wire Glass

0014A At Ground Level 50 SF $______ $_________ 0014B Above Ground Level 50 SF $______ $_________

0015 1” Clear Tempered Glass, Insulated Units

0015A At Ground Level 50 SF $______ $_________ 0015B Above Ground Level 50 SF $______ $_________

0016 1” Tinted Tempered Glass, Insulated Units

0016A At Ground Level 50 SF $______ $_________ 0016B Above Ground Level 50 SF $______ $_________

0017 1/2” Low coating Grey Herculite Glass door With polished edges

0017A At Ground Level 100 SF $______ $_________ 0017B Above Ground Level 100 SF $______ $_________

0018 1 3/8” Blast Resistant Unit Temped/Laminated

0018A At Ground Level 100 SF $______ $_________ 0018B Above Ground Level 100 SF $______ $_________

0019 1 3/8” DOD Blast resistant

0019A At Ground Level 100 SF $______ $_________ 0019B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

0020 3/16 Mirror With 1/2 Bevel

0020A At Ground Level 100 SF $_______ $_________ 0020B Above Ground Level 100 SF $_______ $_________

0021 !/4 gray HS VE-2M#2 1/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT

0021A At Ground Level 100 SF $______ $_________ 0021B Above Ground Level 100 SF $______ $_________

0022 1” Ve3=2M Special product coating Gray Blast Make-up

0022A At Ground Level 100 SF $______ $_________ 0022B Above Ground Level 100 SF $______ $_________

0023 1” Temp over temp laminated insulated unit, Gray blast make-up

0023A At Ground Level 100 SF $_______ $_________ 0023B Above Ground Level 100 SF $_______ $_________

0024 1” Viracon low-E insulated unit

0024A At Ground Level 100 SF $_______ $_________ 0024B Above Ground Level 100 SF $_______ $_________

0025 1” VE-3-2M Gray low coating

0025A At Ground Level 100 SF $_______ $_________ 0025B Above Ground Level 100 SF $_______ $_________

0026 1” laminated / tempered gray with special low-e coating

0025A At Ground Level 100 SF $_______ $_________ 0025B Above Ground Level 100 SF $_______ $_________

0026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap

0026A At Ground Level 100 SF $______ $_________ 0026B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform the following work in accordance with contract specifications

0027 1” Viracon VE3-2M, 1 inch special gray with low-e coating, both lights safety black spacer

0027A At Ground Level 100 SF $______ $_________ 0027B Above Ground Level 100 SF $______ $_________

0028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat

0028A At Ground Level 100 SF $_______ $_________ 0028B Above Ground Level 100 SF $_______ $_________

0029 1” Special tempered, Laminated Blast unit

0029A At Ground Level 100 SF $_______ $_________ 0029B Above Ground Level 100 SF $_______ $_________

0030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer

0030A At Ground Level 100 SF $_______ $_________ 0030B Above Ground Level 100 SF $_______ $_________

0031 1” Clear tempered insulated unit with low-e special coating

0031A At Ground Level 100 SF $_______ $_________ 0031B Above Ground Level 100 SF $_______ $_________

0032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer

0032A At Ground Level 100 SF $_______ $_________ 0032B Above Ground Level 100 SF $_______ $_________

00330 1” Reduce heat transfer glass tinted with blast damage safety film

0033A At Ground Level 100 SF $_______ $_________ 0033B Above Ground Level 100 SF $_______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

0034 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated

0034A At Ground Level 100 SF $_______ $_________ 0034B Above Ground Level 100 SF $_______ $_________

0035 ¼” Lexan MR4000

0035A At Ground Level 5 SF $________ $_________ 0035B Above Ground Level 5 SF $________ $_________

0036 1/8” Plexiglas

0036A At Ground Level 5 SF $_______ $_________ 0036B Above Ground Level 5 SF $_______ $_________

0037 ¼” Plexiglas

0037A At Ground Level 5 SF $______ $85.00 0037B Above Ground Level 5 SF $______ $85.00

0038 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops

0038A At Ground Level 5 SF $_______ $_________ 0038B Above Ground Level 5 SF $_______ $_________

0039 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered

0039A At Ground Level 5 SF $ $_________ 0039B Above Ground Level 5 SF $ $_________

NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of Fairchild Hall, Building 2354.

BASIC YEAR TOTAL $________

0040 Non-Pre-Priced Items (Non-Biddable Item)

Include overhead and profit in unit and extended amount. DO NOT include bonding cost on the bid schedule.

1ST OPTION YEAR

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

1001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed

1001A At Ground Level 100 SF $ $ ________ 1001B Above Ground Level 100 SF $ $_________

1002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied

1002A At Ground Level 500 SF $_______ $________ 1002B Above Ground Level 500 SF $_______ $_________

1003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied

1003A At Ground Level 1,750 SF $_____ $________ 1003B Above Ground Level 1,750 SF $_____ $________

NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line

1004 1” Clear Tempered (Insulated Glass)

Compound, Pneumatically Applied

1004A At Ground Level 250 SF $______ $________ 1004B Above Ground Level 250 SF $______ $________

1005 1” Heat Absorbing Unit, Tempered

1005A At Ground Level 100 SF $_____ $_______ 1005B Above Ground Level 100 SF $_____ $_______

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

1006 3/8” Heat Absorbing, Glare Reducing, Tempered

1006A At Ground Level 60 SF $_____ $________ 1006B Above Ground Level 60 SF $_____ $________

1007 1/8” Rolled Glass, Type III, Set with

(Heat Plant)

1007A At Ground Level 300 SF $_____ $________ 1007B Above Ground Level 300 SF $_____ $________

1008 Seedy, Cathedral Type, Set with

Clips and Black Glazing Compound

1008A At Ground Level 100 SF $_____ $________ 1008B Above Ground Level 100 SF $_____ $________

1009 1/4” Laminated Glass, DS/DS, 1009A At Ground Level 100 SF $_____ $________ 1009B Above Ground Level 100 SF $_____ $________

1010 1/4” Heat Absorbing and Glare

1010A At Ground Level 50 SF $_____ $_______ 1010B Above Ground Level 50 SF $_____ $_______

1011 Porcelain Enamel Panels, “Mirawal”

Pneumatically Applied. Color to Match Existing – Gray or Black

1011A At Ground Level 100 SF $_____ $_________ 1011B Above Ground Level 100 SF $_____ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

1012 Recaulk Existing Glass

1012A At Ground Level 500 LF $______ $_________ 1012B Above Ground Level 500 LF $______ $_________

1013 Mirror, Copper Coated

1013A At Ground Level 250 SF $______ $_________ 1013B Above Ground Level 250 SF $______ $_________

1014 1/4” Wire Glass

1014A At Ground Level 50 SF $______ $_________ 1014B Above Ground Level 50 SF $______ $_________

1015 1” Clear Tempered Glass, Insulated Units

1015A At Ground Level 50 SF $______ $_________ 1015B Above Ground Level 50 SF $______ $_________

1016 1” Tinted Tempered Glass, Insulated Units

1016A At Ground Level 50 SF $______ $_________ 1016B Above Ground Level 50 SF $______ $_________

1017 1” Low coating Grey Herculite Glass door With polished edges

1017A At Ground Level 100 SF $______ $_________ 1017B Above Ground Level 100 SF $______ $_________

1018 1” Blast Resistant Unit Temped/Laminated

1018A At Ground Level 100 SF $______ $_________ 1018B Above Ground Level 100 SF $______ $_________

1019 1” DOD Blast resistant

1019A At Ground Level 100 SF $______ $_________ 1019B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

1020 3/16 Mirror With !/2 Bevel

1020A At Ground Level 100 SF $_______ $_________ 1020B Above Ground Level 100 SF $_______ $_________

1021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT

1021A At Ground Level 100 SF $______ $_________ 1021B Above Ground Level 100 SF $______ $_________

1022 1” Ve3=2M Special product coating Gray Blast Make-up

1022A At Ground Level 100 SF $______ $_________ 1022B Above Ground Level 100 SF $______ $_________

1023 1” Temp over temp laminated insulated unit, Gray blast make-up

1023A At Ground Level 100 SF $_______ $_________ 1023B Above Ground Level 100 SF $_______ $_________

1024 1” Viracon low-E insulated unit

1024A At Ground Level 100 SF $_______ $_________ 1024B Above Ground Level 100 SF $_______ $_________

1025 1” VE-3-2M Gray low coating

1025A At Ground Level 100 SF $_______ $_________ 1025B Above Ground Level 100 SF $_______ $_________

1026 1” laminated / tempered gray with special low-e coating

1025A At Ground Level 100 SF $_______ $_________ 1025B Above Ground Level 100 SF $_______ $_________

1026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap

1026A At Ground Level 100 SF $______ $_________ 1026B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

1027 1” Viracon VE3-2M, 1 inch special gray with spacer

1027A At Ground Level 100 SF $______ $_________ 1027B Above Ground Level 100 SF $______ $_________

1028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat

1028A At Ground Level 100 SF $_______ $_________ 1028B Above Ground Level 100 SF $_______ $_________

1029 1” Special tempered, Laminated Blast unit

1029A At Ground Level 100 SF $_______ $_________ 1029B Above Ground Level 100 SF $_______ $_________

1030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer

1030A At Ground Level 100 SF $_______ $_________ 1030B Above Ground Level 100 SF $_______ $_________

1031 1” Clear tempered insulated unit with low-e special coating

1031A At Ground Level 100 SF $_______ $_________ 1031B Above Ground Level 100 SF $_______ $_________

1032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer

1032A At Ground Level 100 SF $_______ $_________ 1032B Above Ground Level 100 SF $_______ $_________

10330 1” Reduce heat transfer glass tinted with blast damage safety film

1033A At Ground Level 100 SF $_______ $_________ 1033B Above Ground Level 100 SF $_______ $________

1st OPTION YEAR

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

1034 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated

1034A At Ground Level 100 SF $_______ $_________ 1034B Above Ground Level 100 SF $_______ $_________

1035 ¼” Lexan MR4000

1035A At Ground Level 5 SF $________ $_________ 1035B Above Ground Level 5 SF $________ $_________

1036 1/8” Plexiglas

1036A At Ground Level 5 SF $_______ $_________ 1036B Above Ground Level 5 SF $_______ $_________

1037 ¼” Plexiglas

1037A At Ground Level 5 SF $______ $85.00 1037B Above Ground Level 5 SF $______ $85.00

1038 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops

1038A At Ground Level 5 SF $_______ $_________ 1038B Above Ground Level 5 SF $_______ $_________

1039 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered

1039A At Ground Level 5 SF $ $_________ 1039B Above Ground Level 5 SF $ $_________

NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of Fairchild Hall, Building 2354.

1st OPTION YEAR TOTAL $________

1040 Non-Pre-Priced Items (Non-Biddable Item)

2nd OPTION YEAR

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

2001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed

2001A At Ground Level 100 SF $ $ ________ 2001B Above Ground Level 100 SF $ $_________

2002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied

2002A At Ground Level 500 SF $_______ $________ 2002B Above Ground Level 500 SF $_______ $_________

2003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied

2003A At Ground Level 1,750 SF $_____ $________ 2003B Above Ground Level 1,750 SF $_____ $________

NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line

2004 1” Clear Tempered (Insulated Glass)

Compound, Pneumatically Applied

2004A At Ground Level 250 SF $______ $________ 2004B Above Ground Level 250 SF $______ $________

2005 1” Heat Absorbing Unit, Tempered

2005A At Ground Level 100 SF $_____ $_______ 2005B Above Ground Level 100 SF $_____ $_______

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

2006 3/8” Heat Absorbing, Glare Reducing, Tempered

2006A At Ground Level 60 SF $_____ $________ 2006B Above Ground Level 60 SF $_____ $________

2007 1/8” Rolled Glass, Type III, Set with

(Heat Plant)

2007A At Ground Level 300 SF $_____ $________ 2007B Above Ground Level 300 SF $_____ $________

2008 Seedy, Cathedral Type, Set with

Clips and Black Glazing Compound

2008A At Ground Level 100 SF $_____ $________ 2008B Above Ground Level 100 SF $_____ $________

2009 1/4” Laminated Glass, DS/DS, 2009A At Ground Level 100 SF $_____ $________ 2009B Above Ground Level 100 SF $_____ $________

2010 1/4” Heat Absorbing and Glare

2010A At Ground Level 50 SF $_____ $_______ 2010B Above Ground Level 50 SF $_____ $_______

2011 Porcelain Enamel Panels, “Mirawal”

Pneumatically Applied. Color to Match Existing – Gray or Black

2011A At Ground Level 100 SF $_____ $_________ 2011B Above Ground Level 100 SF $_____ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

2012 Recaulk Existing Glass

2012A At Ground Level 500 LF $______ $_________ 2012B Above Ground Level 500 LF $______ $_________

2013 Mirror, Copper Coated

2013A At Ground Level 250 SF $______ $_________ 2013B Above Ground Level 250 SF $______ $_________

2014 1/4” Wire Glass

2014A At Ground Level 50 SF $______ $_________ 2014B Above Ground Level 50 SF $______ $_________

2015 1” Clear Tempered Glass, Insulated Units

2015A At Ground Level 50 SF $______ $_________ 2015B Above Ground Level 50 SF $______ $_________

2016 1” Tinted Tempered Glass, Insulated Units

2016A At Ground Level 50 SF $______ $_________ 2016B Above Ground Level 50 SF $______ $_________

2017 1” Low coating Grey Herculite Glass door With polished edges

2017A At Ground Level 100 SF $______ $_________ 2017B Above Ground Level 100 SF $______ $_________

2018 1” Blast Resistant Unit Temped/Laminated

2018A At Ground Level 100 SF $______ $_________ 2018B Above Ground Level 100 SF $______ $_________

2019 1” DOD Blast resistant

2019A At Ground Level 100 SF $______ $_________ 2019B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

2020 3/16 Mirror With !/2 Bevel

2020A At Ground Level 100 SF $_______ $_________ 2020B Above Ground Level 100 SF $_______ $_________

2021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT

2021A At Ground Level 100 SF $______ $_________ 2021B Above Ground Level 100 SF $______ $_________

2022 1” Ve3=2M Special product coating Gray Blast Make-up

2022A At Ground Level 100 SF $______ $_________ 2022B Above Ground Level 100 SF $______ $_________

2023 1” Temp over temp laminated insulated unit, Gray blast make-up

2023A At Ground Level 100 SF $_______ $_________ 2023B Above Ground Level 100 SF $_______ $_________

2024 1” Viracon low-E insulated unit

2024A At Ground Level 100 SF $_______ $_________ 2024B Above Ground Level 100 SF $_______ $_________

2025 1” VE-3-2M Gray low coating

2025A At Ground Level 100 SF $_______ $_________ 2025B Above Ground Level 100 SF $_______ $_________

2026 1” laminated / tempered gray with special low-e coating

2025A At Ground Level 100 SF $_______ $_________ 2025B Above Ground Level 100 SF $_______ $_________

2026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap

2026A At Ground Level 100 SF $______ $_________ 2026B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform the following work in accordance with contract specifications

2027 1” Viracon VE3-2M, 1 inch special gray with spacer

2027A At Ground Level 100 SF $______ $_________ 2027B Above Ground Level 100 SF $______ $_________

2028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat

2028A At Ground Level 100 SF $_______ $_________ 2028B Above Ground Level 100 SF $_______ $_________

2029 1” Special tempered, Laminated Blast unit

2029A At Ground Level 100 SF $_______ $_________ 2029B Above Ground Level 100 SF $_______ $_________

2030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer

2030A At Ground Level 100 SF $_______ $_________ 2030B Above Ground Level 100 SF $_______ $_________

2031 1” Clear tempered insulated unit with low-e special coating

2031A At Ground Level 100 SF $_______ $_________ 2031B Above Ground Level 100 SF $_______ $_________

2032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer

2032A At Ground Level 100 SF $_______ $_________ 2032B Above Ground Level 100 SF $_______ $_________

20330 1” Reduce heat transfer glass tinted with blast damage safety film

2033A At Ground Level 100 SF $_______ $_________ 2033B Above Ground Level 100 SF $_______ $_________

2040 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered

2040A At Ground Level 5 SF $ $_________ 2040B Above Ground Level 5 SF $ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

2034 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated

2034A At Ground Level 100 SF $_______ $_________ 2034B Above Ground Level 100 SF $_______ $_________

2035 ¼” Lexan MR4000

2035A At Ground Level 5 SF $________ $_________ 2035B Above Ground Level 5 SF $________ $_________

2036 1/8” Plexiglas

2036A At Ground Level 5 SF $_______ $_________ 2036B Above Ground Level 5 SF $_______ $_________

2037 ¼” Plexiglas

2037A At Ground Level 5 SF $______ $85.00 2037B Above Ground Level 5 SF $______ $85.00

2038 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops

2038A At Ground Level 5 SF $_______ $_________ 2038B Above Ground Level 5 SF $_______ $_________

2039 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered

2039A At Ground Level 5 SF $ $_________ 2039B Above Ground Level 5 SF $ $_________

NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of

2nd OPTION YEAR TOTAL $________

2040 Non-Pre-Priced Items (Non-Biddable Item)

3rd OPTION YEAR

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

3001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed

3001A At Ground Level 100 SF $ $ ________ 3001B Above Ground Level 100 SF $ $_________

3002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied

3002A At Ground Level 500 SF $_______ $________ 3002B Above Ground Level 500 SF $_______ $_________

3003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied

3003A At Ground Level 1,750 SF $_____ $________ 3003B Above Ground Level 1,750 SF $_____ $________

NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line

3004 1” Clear Tempered (Insulated Glass)

Compound, Pneumatically Applied

3004A At Ground Level 250 SF $______ $________ 3004B Above Ground Level 250 SF $______ $________

3005 1” Heat Absorbing Unit, Tempered

3005A At Ground Level 100 SF $_____ $_______ 3005B Above Ground Level 100 SF $_____ $_______

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

3006 3/8” Heat Absorbing, Glare Reducing, Tempered

3006A At Ground Level 60 SF $_____ $________ 3006B Above Ground Level 60 SF $_____ $________

3007 1/8” Rolled Glass, Type III, Set with

(Heat Plant)

3007A At Ground Level 300 SF $_____ $________ 3007B Above Ground Level 300 SF $_____ $________

3008 Seedy, Cathedral Type, Set with

Clips and Black Glazing Compound

3008A At Ground Level 100 SF $_____ $________ 3008B Above Ground Level 100 SF $_____ $________

3009 1/4” Laminated Glass, DS/DS, 3009A At Ground Level 100 SF $_____ $________ 3009B Above Ground Level 100 SF $_____ $________

3010 1/4” Heat Absorbing and Glare

3010A At Ground Level 50 SF $_____ $_______ 3010B Above Ground Level 50 SF $_____ $_______

3011 Porcelain Enamel Panels, “Mirawal”

Pneumatically Applied. Color to Match Existing – Gray or Black

3011A At Ground Level 100 SF $_____ $_________ 3011B Above Ground Level 100 SF $_____ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

3012 Recaulk Existing Glass

3012A At Ground Level 500 LF $______ $_________ 3012B Above Ground Level 500 LF $______ $_________

3013 Mirror, Copper Coated

3013A At Ground Level 250 SF $______ $_________ 3013B Above Ground Level 250 SF $______ $_________

3014 1/4” Wire Glass

3014A At Ground Level 50 SF $______ $_________ 3014B Above Ground Level 50 SF $______ $_________

3015 1” Clear Tempered Glass, Insulated Units

3015A At Ground Level 50 SF $______ $_________ 3015B Above Ground Level 50 SF $______ $_________

3016 1” Tinted Tempered Glass, Insulated Units

3016A At Ground Level 50 SF $______ $_________ 3016B Above Ground Level 50 SF $______ $_________

3017 1” Low coating Grey Herculite Glass door With polished edges

3017A At Ground Level 100 SF $______ $_________ 3017B Above Ground Level 100 SF $______ $_________

3018 1” Blast Resistant Unit Temped/Laminated

3018A At Ground Level 100 SF $______ $_________ 3018B Above Ground Level 100 SF $______ $_________

3019 1” DOD Blast resistant

3019A At Ground Level 100 SF $______ $_________ 3019B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

3020 3/16 Mirror With !/2 Bevel

3020A At Ground Level 100 SF $_______ $_________ 3020B Above Ground Level 100 SF $_______ $_________

3021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT

3021A At Ground Level 100 SF $______ $_________ 3021B Above Ground Level 100 SF $______ $_________

3022 1” Ve3=2M Special product coating Gray Blast Make-up

3022A At Ground Level 100 SF $______ $_________ 3022B Above Ground Level 100 SF $______ $_________

3023 1” Temp over temp laminated insulated unit, Gray blast make-up

3023A At Ground Level 100 SF $_______ $_________ 3023B Above Ground Level 100 SF $_______ $_________

3024 1” Viracon low-E insulated unit

3024A At Ground Level 100 SF $_______ $_________ 3024B Above Ground Level 100 SF $_______ $_________

3025 1” VE-3-2M Gray low coating

3025A At Ground Level 100 SF $_______ $_________ 3025B Above Ground Level 100 SF $_______ $_________

3026 1” laminated / tempered gray with special low-e coating

3025A At Ground Level 100 SF $_______ $_________ 3025B Above Ground Level 100 SF $_______ $_________

3026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap

3026A At Ground Level 100 SF $______ $_________ 3026B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

3027 1” Viracon VE3-2M, 1 inch special gray with spacer

3027A At Ground Level 100 SF $______ $_________ 3027B Above Ground Level 100 SF $______ $_________

3028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat

3028A At Ground Level 100 SF $_______ $_________ 3028B Above Ground Level 100 SF $_______ $_________

3029 1” Special tempered, Laminated Blast unit

3029A At Ground Level 100 SF $_______ $_________ 3029B Above Ground Level 100 SF $_______ $_________

3030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer

3030A At Ground Level 100 SF $_______ $_________ 3030B Above Ground Level 100 SF $_______ $_________

3031 1” Clear tempered insulated unit with low-e special coating

3031A At Ground Level 100 SF $_______ $_________ 3031B Above Ground Level 100 SF $_______ $_________

3032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer

3032A At Ground Level 100 SF $_______ $_________ 3032B Above Ground Level 100 SF $_______ $_________

30330 1” Reduce heat transfer glass tinted with blast damage safety film

3033A At Ground Level 100 SF $_______ $_________ 3033B Above Ground Level 100 SF $_______ $_________

3RD OPTION YEAR

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

3034 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated

3034A At Ground Level 100 SF $_______ $_________ 3034B Above Ground Level 100 SF $_______ $_________

3035 ¼” Lexan MR4000

3035A At Ground Level 5 SF $________ $_________ 3035B Above Ground Level 5 SF $________ $_________

3036 1/8” Plexiglas

3036A At Ground Level 5 SF $_______ $_________ 3036B Above Ground Level 5 SF $_______ $_________

3037 ¼” Plexiglas

3037A At Ground Level 5 SF $______ $85.00 3037B Above Ground Level 5 SF $______ $85.00

3038 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops

3038A At Ground Level 5 SF $_______ $_________ 3038B Above Ground Level 5 SF $_______ $_________

3039 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered

3039A At Ground Level 5 SF $ $_________ 3039B Above Ground Level 5 SF $ $_________

NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of

3rd OPTION YEAR TOTAL $________

3040 Non-Pre-Priced Items (Non-Biddable Item)

4Th OPTION YEAR

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

4001 1/8” Double Strength, Float Glass, Set with Glazing Compound, Face Glazed

4001A At Ground Level 100 SF $ $ ________ 4001B Above Ground Level 100 SF $ $_________

4002 1/4” Tempered Float Glass, Neoprene Tubing Tape or Elastomer Sealing Compound, Pneumatically Applied

4002A At Ground Level 500 SF $_______ $________ 4002B Above Ground Level 500 SF $_______ $_________

4003 1/4” Heat Absorbing, Glare Reducing, Tempered, Float Glass, Set to Match Existing with Neoprene Tubing or Elastomer Sealing Compound, Pneumatically Applied

4003A At Ground Level 1,750 SF $_____ $________ 4003B Above Ground Level 1,750 SF $_____ $________

NOTE: The two lites in the Cadet Dormitories referred to in Paragraph 1.1.2.1. fall under the above line

4004 1” Clear Tempered (Insulated Glass)

Compound, Pneumatically Applied

4004A At Ground Level 250 SF $______ $________ 4004B Above Ground Level 250 SF $______ $________

4005 1” Heat Absorbing Unit, Tempered

4005A At Ground Level 100 SF $_____ $_______ 4005B Above Ground Level 100 SF $_____ $_______

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

EST UNIT EXTENDED

ITEM DESCRIPTION QTY UNIT PRICE AMOUNT

4006 3/8” Heat Absorbing, Glare Reducing, Tempered

4006A At Ground Level 60 SF $_____ $________ 4006B Above Ground Level 60 SF $_____ $________

4007 1/8” Rolled Glass, Type III, Set with

(Heat Plant)

4007A At Ground Level 300 SF $_____ $________ 4007B Above Ground Level 300 SF $_____ $________

4008 Seedy, Cathedral Type, Set with

Clips and Black Glazing Compound

4008A At Ground Level 100 SF $_____ $________ 4008B Above Ground Level 100 SF $_____ $________

4009 1/4” Laminated Glass, DS/DS, 4009A At Ground Level 100 SF $_____ $________ 4009B Above Ground Level 100 SF $_____ $________

4010 1/4” Heat Absorbing and Glare

4010A At Ground Level 50 SF $_____ $_______ 4010B Above Ground Level 50 SF $_____ $_______

4011 Porcelain Enamel Panels, “Mirawal”

Pneumatically Applied. Color to Match Existing – Gray or Black

4011A At Ground Level 100 SF $_____ $_________ 4011B Above Ground Level 100 SF $_____ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

4012 Recaulk Existing Glass

4012A At Ground Level 500 LF $______ $_________ 4012B Above Ground Level 500 LF $______ $_________

4013 Mirror, Copper Coated

4013A At Ground Level 250 SF $______ $_________ 4013B Above Ground Level 250 SF $______ $_________

4014 1/4” Wire Glass

4014A At Ground Level 50 SF $______ $_________ 4014B Above Ground Level 50 SF $______ $_________

4015 1” Clear Tempered Glass, Insulated Units

4015A At Ground Level 50 SF $______ $_________ 4015B Above Ground Level 50 SF $______ $_________

4016 1” Tinted Tempered Glass, Insulated Units

4016A At Ground Level 50 SF $______ $_________ 4016B Above Ground Level 50 SF $______ $_________

4017 1” Low coating Grey Herculite Glass door With polished edges

4017A At Ground Level 100 SF $______ $_________ 4017B Above Ground Level 100 SF $______ $_________

4018 1” Blast Resistant Unit Temped/Laminated

4018A At Ground Level 100 SF $______ $_________ 4018B Above Ground Level 100 SF $______ $_________

4019 1” DOD Blast resistant

4019A At Ground Level 100 SF $______ $_________ 4019B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

4020 3/16 Mirror With !/2 Bevel

4020A At Ground Level 100 SF $_______ $_________ 4020B Above Ground Level 100 SF $_______ $_________

4021 !/4 gray HS VE-2M#2 !/2 Air Space Black Spacer, ¼ Clear Temper, V907#4 FRIT

4021A At Ground Level 100 SF $______ $_________ 4021B Above Ground Level 100 SF $______ $_________

4022 1” Ve3=2M Special product coating Gray Blast Make-up

4022A At Ground Level 100 SF $______ $_________ 4022B Above Ground Level 100 SF $______ $_________

4023 1” Temp over temp laminated insulated unit, Gray blast make-up

4023A At Ground Level 100 SF $_______ $_________ 4023B Above Ground Level 100 SF $_______ $_________

4024 1” Viracon low-E insulated unit

4024A At Ground Level 100 SF $_______ $_________ 4024B Above Ground Level 100 SF $_______ $_________

4025 1” VE-3-2M Gray low coating

4025A At Ground Level 100 SF $_______ $_________ 4025B Above Ground Level 100 SF $_______ $_________

4026 1” laminated / tempered gray with special low-e coating

4025A At Ground Level 100 SF $_______ $_________ 4025B Above Ground Level 100 SF $_______ $_________

4026 1” VE3-2M, 1/4gray HS VE2M#2, ½ Air Space (Black), ¼ clear tap

4026A At Ground Level 100 SF $______ $_________ 4026B Above Ground Level 100 SF $______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

4027 1” Viracon VE3-2M, 1 inch special gray with spacer

4027A At Ground Level 100 SF $______ $_________ 4027B Above Ground Level 100 SF $______ $_________

4028 1“ Bullet resistant unit (UL Rated), with high performance reflective special Low-E coat

4028A At Ground Level 100 SF $_______ $_________ 4028B Above Ground Level 100 SF $_______ $_________

4029 1” Special tempered, Laminated Blast unit

4029A At Ground Level 100 SF $_______ $_________ 4029B Above Ground Level 100 SF $_______ $_________

4030 1” Original Viracon Special gray, with low-e coating both lights safety black spacer

4030A At Ground Level 100 SF $_______ $_________ 4030B Above Ground Level 100 SF $_______ $_________

4031 1” Clear tempered insulated unit with low-e special coating

4031A At Ground Level 100 SF $_______ $_________ 4031B Above Ground Level 100 SF $_______ $_________

4032 1 3/16 Tempered / Laminated unit with high performance low-e coating, black Spacer

4032A At Ground Level 100 SF $_______ $_________ 4032B Above Ground Level 100 SF $_______ $_________

40330 1” Reduce heat transfer glass tinted with blast damage safety film

4033A At Ground Level 100 SF $_______ $_________ 4033B Above Ground Level 100 SF $_______ $_________

The contractor shall furnish all personnel, labor, equipment, materials, and other items necessary to perform

4034 1 3/16” DOD Blast resistant plus low-e coating ¼” Solar ban tempered clear ½” black air space, 7/16” clear tempered laminated

4034A At Ground Level 100 SF $_______ $_________ 4034B Above Ground Level 100 SF $_______ $_________

4035 ¼” Lexan MR4000

4035A At Ground Level 5 SF $________ $_________ 4035B Above Ground Level 5 SF $________ $_________

4036 1/8” Plexiglas

4036A At Ground Level 5 SF $_______ $_________ 4036B Above Ground Level 5 SF $_______ $_________

4037 ¼” Plexiglas

4037A At Ground Level 5 SF $______ $85.00 4037B Above Ground Level 5 SF $______ $85.00

4038 ¼” Plexiglas, Sandblasted set with elastomer compound and pneumatically applied or set with glazing compound and steel stops

4038A At Ground Level 5 SF $_______ $_________ 4038B Above Ground Level 5 SF $_______ $_________

4039 Non-Blast type -2VE2M#2 ¼ grey, H/S VE-2M#2 ½ Black Spacer ¼ clear tempered

4039A At Ground Level 5 SF $ $_________ 4039B Above Ground Level 5 SF $ $_________

NOTE: Items 0015 and 0016 pertain to glass units at the Cadet Library clerestory and the north tower of

4th OPTION YEAR TOTAL $________

4040 Non-Pre-Priced Items (Non-Biddable Item)

File details come from the government source that posted it. Updated .