About this file

This document contains architectural drawings for replacing the roof on Building 411 at Pittsburgh International Airport Air Reserve Station. The drawings show the existing roof layout and details for demolition and installation of a new roof system. Technical notes specify removing the existing roof insulation and vapor barrier, carefully removing all copings, gravel stops, flashing and conductor heads from all roof levels and parapets. The contractor must schedule demolition and new work installation to prevent water damage, ensure uninterrupted operation of roof antennas, and report any differing site conditions prior to work. No fasteners in the new roof system or pooled water areas will be allowed.

The related federal contract opportunity is a solicitation from the Department of the Air Force Reserve Command to replace the roof on Building 411 at the Pittsburgh International Airport Air Reserve Station.

View the file

Other files for this federal contract opportunity

Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

326337

319318

119 20

B U S

IN

E S S

IN

T E R S T A T E

CARTER ST

BRO

W N

ST

H E R M A N

S T

APRON AREA

ENGINE

TEST

STAND

SS

SS

wa ter tow er o d p

Q

N

E

E C

C

C

C

G

H

I

J

K

L

M

N

O

P

S

R

N-2

D E F E N S E

CARTER ST

AIR

LIF

T A

VE

SABRE ST

BRO

W N

ST

SA

BR

E

ST

DE

FE

NS

E

AV

E

MILLER ST

AV

E

D E F E N S E A

V E

SER

GEAN

TS

WAY

SA

BR

E

ST

CARTER ST

AL

PH

A S T

DEFENSE

ALPHA ST

ROCKY LANE

SA

BR

E

ST

DRMO PAD

RAPID RUNWAY REPAIR

PI

CN

IC

P

AV

CONC. DOCK

SAND&GRAVEL STORAGE

DOUBLE

GATE

DOUBLE

GATE

SLIDING

GATE

DOUBLE

GATE

DOUBLE

GATE

DOUBLE

GATE

DOUBLE

GATE

DOUBLE

GATE

SLIDING

GATE

DOUBLE

GATE

MAIN

GATE

DOUBLE

GATE

DOUBLE

GATES

HAZARD

MAT. STOR.

M f a g b l c k j i n h

E

R

DOUBLE

GATE

SLIDING

GATE

C18

ECP

SLIDING

GATE

SS

DOUBLE

GATE

S

A B

C

Q

DOUBLE

GATEF

DOUBLE

GATEE

DOUBLE

GATE

D

DOUBLE

GATE

DOUBLE

GATE

BA

SK

ET

BA

LL

DE

FE

N

SE

A

VE

A V E

VOLLEYBALL

OBSTACLE

COURSE

N

O

R

T

H

(BLDG 333)

CIVIL ENGINEERING

GATE HOUSE

(BLDG 411)

PROJECT

LOCATION

MAIN

(BLDG 108)

NOT TO SCALE

A-1

21 OCT 2021JLSS 21-0005

GTP 210-174

2 3

AutoCAD SHX Text

BUSINESS INTERSTATE 376

AutoCAD SHX Text DEMOLITION TECHNICAL NOTES: 1. REMOVE EXISTING ROOF INSULATION AND VAPOR BARRIER REMOVE EXISTING ROOF INSULATION AND VAPOR BARRIER (IF PRESENT) FROM ALL EXISTING ROOF SURFACE. 2. CAREFULLY REMOVE ALL COPINGS, GRAVEL STOPS, CAREFULLY REMOVE ALL COPINGS, GRAVEL STOPS, FLASHING & CONDUCTOR HEADS FROM ALL EXISTING ROOF LEVELS & PARAPETS. 3. UNLESS NOTED, ALL ROOFTOP EQUIPMENT LISTED IS TO UNLESS NOTED, ALL ROOFTOP EQUIPMENT LISTED IS TO BE PROTECTED FROM THIS WORK AND REMAIN IN OPERATION. EXISTING PIPE VENTS, DUCTWORK, SUPPORT CURBS AND SUPPORT POSTS TO REMAIN IN PLACE. 4. CONTRACTOR TO SCHEDULE DEMOLITION AND CONTRACTOR TO SCHEDULE DEMOLITION AND INSTALLATION OF NEW WORK TO PREVENT WATER DAMAGE TO EXISTING FACILITY AT ALL TIMES. 5. ENSURE OPERATION OF ANTENNAS LOCATED ON ROOF IS ENSURE OPERATION OF ANTENNAS LOCATED ON ROOF IS UNINTERRUPTED DURING PROJECT; COORDINATE WITH USING AGENCIES AS NECESSARY.

AutoCAD SHX Text GENERAL NOTES: 1. PROVIDE NEW GUTTERS AT ALL PREVIOUS LOCATIONS. NEW PROVIDE NEW GUTTERS AT ALL PREVIOUS LOCATIONS. NEW GUTTERS, CONFIGURATIONS AND SUPPORT TO MATCH EXISTING. 2. CONTRACTOR TO REPORT, IN WRITING, DIFFERING OR CONTRACTOR TO REPORT, IN WRITING, DIFFERING OR UNACCEPTABLE SITE CONDITIONS TO THE ATTENTION OF THE CONTRACTING OFFICER PRIOR TO PERFORMING WORK. FAILURE TO DO SO SHALL CONSTITUTE ACCEPTANCE OF CONDITIONS WITHOUT RESERVATIONS. 3. NO FASTENERS IN NEW ROOF SYSTEM SHALL BE EXPOSED. NO FASTENERS IN NEW ROOF SYSTEM SHALL BE EXPOSED. 4. NO POOLED WATER AREAS WILL BE PERMISSIBLE ON FINISHED NO POOLED WATER AREAS WILL BE PERMISSIBLE ON FINISHED ROOF.

AutoCAD SHX Text

CHIEF ENGINEERING FLIGHT

AutoCAD SHX Text

BIO ENVIRONMENTAL

AutoCAD SHX Text

BY

AutoCAD SHX Text

U.S. AIR FORCE

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

DATE

AutoCAD SHX Text

BASE CIVIL ENGINEER

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SECURITY

AutoCAD SHX Text

SAFETY

AutoCAD SHX Text

FIRE

AutoCAD SHX Text

ENVIRONMENTAL ENGINEERING

AutoCAD SHX Text

COMMUNICATIONS

AutoCAD SHX Text

REV. NO.

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

CHECKED BY:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

MOON TOWNSHIP, PA 15108-4495

AutoCAD SHX Text

911TH AIRLIFT WING

AutoCAD SHX Text

PITTSBURGH INTERNATIONAL AIRPORT, ARS

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

CHIEF CE OPERATIONS

AutoCAD SHX Text

PROJECT NO.:

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text

DATE

AutoCAD SHX Text

COORDINATION

AutoCAD SHX Text

REVIEW

AutoCAD SHX Text

ANTI-TERRORISM

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text

BDK

AutoCAD SHX Text

BDK

AutoCAD SHX Text

USING AGENCY

AutoCAD SHX Text

REPLACE ROOF BLDG 411

AutoCAD SHX Text

DG

Sheets and Views
Project Location