Sheets_Referred_To_In_Responses_To_Be_Posted-4.pdf

PDF 1 MB Posted

Attached to
Building 1630 Renovation
Solicitation number
FA667518R0002
Issued by

About this file

Sheets Referred To In Responses To Be Posted-4

View the file

Other files

File Type Posted
Responses_To_Be_Posted-5.pdf PDF
Responses_To_Be_Posted-4.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_Demolition_Specification_02_41_00.pdf PDF
SUBMITTALS_REGISTER_-_Revised.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_Spec_03_35_43_Polished_Concrete.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_COMM_Drawings.pdf PDF
Table_of_Contents.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_-_Specifications_(Revision__4).pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_Concrete_Joint_Spec_05_72_00.pdf PDF
FA6675-18-R-0002_B1630_Amendment__2.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_EFIS_System_Spec_07_24_00_(Revised).pdf PDF
FA6675-18-R-0002_B1630_Amendment__3.pdf PDF
RFI_Responses_To_Be_Posted-3.pdf PDF
RFI_Responses_To_Be_Posted-2.pdf PDF
RFI_Responses_To_Be_Posted.pdf PDF
FA6675-18-R-0002_B1630_Amendment__2.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_Demolition_Specification_02_41_00.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_-_Specifications_(Revision__4).pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_EFIS_System_Spec_07_24_00_(Revised).pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_Concrete_Joint_Spec_05_72_00.pdf PDF
Table_of_Contents.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_COMM_Drawings.pdf PDF
FA6675-16-R-0007_LIFE_SUPPORT_Spec_03_35_43_Polished_Concrete.pdf PDF
SUBMITTALS_REGISTER_-_Revised.pdf PDF
RFI_-RFC_FORM.pdf PDF
Site_Visit_Sign-in_Sheet_-_20180327.pdf PDF
FA6675-18-R-0002_B1630_Amendment__1.pdf PDF
ATT10-95145107-Geotech_Report.pdf PDF
ATT15-SF24_Bid_Bond_Blank_Form.pdf PDF
ATT12-1630_-_DDPM_120002_-_Concrete_Joint_-_Spec_05_72_00.pdf PDF
ATT7-Wage_Determinations_-_1-12-2018.pdf PDF
ATT2-B1630_A&E_Dev_Specs_-_Comm_Line_Relocation.pdf PDF
ATT14-RFI_Form.pdf PDF
ATT4-B1630_Comm_Line_Relocate_Drawings.pdf PDF
FA667518R0002_B1630_Solicitation.pdf PDF
ATT8-Asbestos_Report_F5A6CE7363AW01_B1630_RENOVATE_LIFE_SUPPORT.pdf PDF
ATT6-B1630__Basis_of_Design_-_Comm_Line_Relocate.pdf PDF
ATT9-B1630_Lead_Based_Paint_Report.pdf PDF
ATT13-Spec_03_35_43_Polished_Concrete.pdf PDF
ATT3-B1630_Renovation_Drawings.pdf PDF
ATT5-B1630_Basis_of_Design_-_Addition_Renovation.pdf PDF
ATT1-B1630_A&E_Dev_Specs_-_Addition_Renovation.pdf PDF
ATT11-RFI_Clarifications.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

0"

B.O. EXIST TRUSS

10'-0"

T.O.F -2'-0"

2' -0

3'

-0

3' -0

CONCRETE FOUNDATION.

SEE STRUCTURAL

EXTERIOR INSULATED

FINISH SYSTEM

ALUMINUM WINDOW

FLOOR AS

SCHEDULED

5/8" GYPSUM

WALL BOARD

BATT. INSULATION

5/8" GYPSUM BOARD

FURRDOWN ON 3-5/8"

METAL STUDS

3-5/8" METAL

STUDS

GABLE END TRUSS.

SEE S-301

1/2" SHEATHING

EIFS CONTROL JOINT

FINISH GRADE

PROVIDE POSITIVE

DRAINAGE AWAY

FROM BLDG. SEE

CIVIL NOTES.

GROUT FILL CAVITY

UP TO FINISH FLOOR

PRE-FINISHED STANDING

SEAM METAL ROOF

CONTINUOUS

UNDERLAYMENT

BARRIER BOARD

METAL DECK

SEE S-301

RIGID INSULATION

R-20

CEILING GRID

AS SCHEDULED

8" CMU BOND BEAM.

SEE S-301

8" CMU WITH REINFORCEMENT.

SEE SHEET S-301.

FLOOR BASE AS SCHEDULED

CONCRETE SLAB

SEE STRUCTURAL

CAPILLARY BARRIER

SEE S-301

EXPANSION MATERIAL

A-501 A3

A-501 C4

A-501 B4

T.O. NEW CMU

10'-4"

FLUID-APPLIED

DAMP PROOFING,

ABOVE GRADE

8" SPLIT FACED

CMU VENEER

4" SPLIT FACED

CMU VENEER

8" SPLIT FACED

CMU VENEER

SPLIT FACE CMU

CAP

2" EPS

EXTERIOR INSULATED

FINISH SYSTEM

BITUMINOUS DAMP

PROOFING, BELOW

GRADE

FIRST FLOOR

0"

B.O. EXIST TRUSS

10'-0"

T.O.F -2'-0"

FLOOR AS

SCHEDULED

5/8" GYPSUM

WALL BOARD

3-1/2" BATT

INSULATION

EXISTING CLAY

BLOCK WALL

EXISTING

CONCRETE

FOOTING

STANDING SEAM

METAL ROOFING

OVER RIGID

INSULATION

EXTERIOR METAL

CANOPY

3' -0

5'

-2

/8

4' -7

/2

2' -1

1/

4" 2'

-4

/2

8" SPLIT FACED

CMU VENEER

3-5/8" METAL

STUDS

EXISTING ROOF

TRUSS

CEILING AS

SCHEDULED

EXISTING

CONCRETE SLAB

A-501 A1

T.O. NEW CMU

10'-4"

4" SPLIT FACED

CMU VENEER

8" SPLIT FACED

CMU VENEER

4" SPLIT FACED

CMU VENEER

8" SPLIT FACED

CMU VENEER

BURNISHED CMU

CAP

FLUID-APPLIED

DAMP PROOFING,

ABOVE GRADE

BITUMINOUS DAMP

PROOFING, BELOW

GRADE

1 FIRST FLOOR

0"

B.O. EXIST TRUSS

10'-0"

T.O.F -2'-0"

A

FLOOR AS

SCHEDULED

5/8" GYPSUM

WALL BOARD

8" CMU WALL

CEILING AS

SCHEDULED

PRE-ENGINEERED

METAL TRUSSES

STANDING SEAM

METAL ROOFING

OVER RIGID

INSULATION

EXTERIOR METAL

CANOPY

8" SPLIT FACED

CMU VENEER

3-5/8" METAL

STUDS

A-501 D1

T.O. NEW CMU

10'-4"

AFE LOCKERS

4" SPLIT FACED

CMU VENEER

8" SPLIT FACED

CMU VENEER

4" SPLIT FACED

CMU VENEER

8" SPLIT FACED

CMU VENEER

BURNISHED CMU

CAP

FLUID-APPLIED

DAMP PROOFING,

ABOVE GRADE

BITUMINOUS DAMP

PROOFING, BELOW

GRADE

FIRST FLOOR

0"

B.O. EXIST TRUSS

10'-0"

T.O.F -2'-0"

D

EXISTING

CONCRETE

FOOTING

FLOOR AS

SCHEDULED

EXISTING STEEL

COLUMN

3-1/2" BATT INSULATION

5/8" GYPSUM BOARD

ON 3-5/8" METAL STUDS

AT 16" O.C. TYP.

PREFINISHED METAL

GUTTER

EXISTING METAL

DECK

EXISTING SPRAY-ON

INSULATION

EXISTING STEEL

BEAM

METAL DECK SEE S-301

CONTINUOUS RIGID

INSULATION (R-20)

BARRIER BOARD

UNDERLAYMENT

PRE-FINISHED

STANDING SEAM

METAL ROOF

4" / 12"

EXISTING WOOD

PURLINS

EXISTING

PURLINS

EXISTING STEEL

TRUSS SUPPORTING

ROOF PURLINS

CEILING AS

SCHEDULE

5/8" GYPSUM

BOARD ON 3-5/8"

METAL STUDS AT

16" O.C. TYP.

EXISTING

CONCRETE

SLAB

EXISTING SPRAY-ON

INSULATION

EXISTING CLAY BRICK

TILE

EXISTING STEEL COLUMN

EXISTING CONCRETE SLAB

FLOOR AS SCHEDULED

MOBILITY &

STORAGE

A105

LOCKER ROOM

A103

A-501 C3

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

N

AV

AL

A

IR

S

TA

TI

O N

C

KD

B Y:

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

SHEET OF

SA

N

PE

DR

O

S

UI

TE

SA

N

AN

T O

NI

O , T

EX

A S

0-

4-

FA

X

0-

3- 3 1

W

W W

.R

SA

ND

H.

CO

M

TX

C

ER

T.

N O

. F

- 3

AS

S

H O

W N

4/

/ 2

1:

: 3

PM

O F

3 0

L I

FE

S U

PP

O

R T

B U

IL

D

IN

G

0 , D D

P M

/1

6/

5D

FA

-1

0- D

-0

EG TA BW

M

A-302

JO

IN

T R

E S

ER

V E B

AS

E

FO

R

T W

O R

T H , T

X

JH

W

AL

L

SE

C T I

O N

S

A D D

I T

IO

N /R

EN

O

VA

TI

O N

SCALE: 1/2" = 1'-0"

A-301

B1 WALL SECTION

SCALE: 1/2" = 1'-0"

A-301

B2 WALL SECTION

SCALE: 1/2" = 1'-0"

A-301

B3 WALL SECTION SCALE: 1/2" = 1'-0"

A-301

B4 WALL SECTION

1 2 42

SCALE: 1/2"=1'-0"

GRAPHIC SCALE

NOTES:

1. BATT INSULATION SHALL BE CONTINUOUS TO THE

UNDERSIDE OF METAL DECK.

2. SUPPORT CONTINUOUS BATT INSULATION ABOVE.

STUD FRAMING WITH WIRE MESH.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

R

FI

4/

/1

1. STUD DESIGN CRITERIA: ALL INTERIOR, NON-LOAD BEARING METAL STUDS SHALL

BE 25 GAUGE (MIN.) UNLESS OTHERWISE NOTED. STUDS SHALL BE DESIGNED FOR A

5 PSF MIN. APPLIED LATERAL LOAD, L/240 MAX. DEFLECTION STUD THICKNESS (GA.)

AND DEPTHS INDICATED ARE MINIMUMS, WHILE STUD SPACING IS A MAXIMUM ON

CENTER SPACING. WHERE REQUIRED PARTITION HEIGHTS EXCEED ALLOWABLE

CRITERIA, STUD THICKNESS SHALL BE INCREASED AND/OR STUD SPACING REDUCED

AS REQUIRED TO MEET STATED CRITERIA. WHERE WALL HUNG CABINETS,

EQUIPMENT, OR FIXTURES ARE INDICATED, PROVIDE 20 GA. MIN. STUDS.

2. TYPICAL FLOOR PLAN DIMENSIONS OF PARTITIONS ARE TO FACE OF GWB OR TO

COLUMN CENTERLINE.

3. INSTALLATION OF GYPSUM BOARD, BACKER BOARD, AND BASE BOARD SHALL

CONFORM TO REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS.

4. PROVIDE WATER RESISTANT TYPE TILE BACKER BOARD AT AREAS THAT ARE NOTED

IN ROOM FINISH SCHEDULE TO RECEIVE CERAMIC OR PORCELAIN TILE FINISH.

5. PROVIDE 5/8" GYPSUM BOARD UNLESS OTHERWISE NOTED.

6. PROVIDE 5/8" TYPE X GYPSUM BOARD AT FIRE RATED PARTITIONS.

7. GA (IF NOTED) AND UL TEST NUMBERS WILL VARY DEPENDING ON THE

MANUFACTURER OF COMPONENTS ACTUALLY USED.

8. INSTALL BLOCKING OR BACKER MATERIAL FOR ATTACHMENT/MOUNTING OF WALL

HUNG ITEMS OR EQUIPMENT DESCRIBED IN THE DOCUMENTS.

9. WHEN INSTALLING GYPSUM BOARD, CONTRACTOR SHALL COMPLY WITH

REQUIREMENTS OF THE MOST CURRENT EDITION OF THE GYPSUM ASSOCIATION GA-

600 FIRE RESISTANCE DESIGN MANUAL AND THE MOST CURRENT EDITION OF THE UL

FIRE RESISTANCE DIRECTORY.

10.PARTITIONS THAT ARE REQUIRED TO EXTEND TO THE DECK ABOVE SHALL HAVE THE

GWB CUT TO FIT WITHIN A 1/4" MAXIMUM TOLERANCE TO THE SHAPE OF THE DECK

ABOVE. GWB SHALL BE CONTINUOUSLY SEALED FOR THE FULL DEPTH OF THE GWB

WITH FLEXIBLE SEALANT.

11.GWB SHALL BE CUT SO THAT THE CLEARANCE BETWEEN METALLIC ELEC. OUTLET

BOXES AND THE GWB DOES NOT EXCEED 1/8".

12.THE BOTTOM OF THE GWB AT INTERIOR PARTITIONS SHALL BE 1/4" MINIMUM AND

1/2" MAXIMUM ABOVE THE CONCRETE FLOOR SLAB AND SHALL BE SEALED FOR THE

FULL DEPTH OF THE GWB WITH FLEXIBLE SEALANT.

13.REFER TO THE FLOOR PLAN FOR EXTENT OF FIRE WALL RATINGS.

14.ALL PARTITIONS SHALL BE ACOUSTICALLY RATED UNLESS OTHERWISE NOTED. ALL

ELEMENTS OF ACOUSTIC RATED PARTITIONS SHALL EXTEND TO ROOF OR FLOOR

DECK ABOVE.

15.NOTE: SOME PARTITION TYPES MAY NOT BE USED ON THIS PROJECT.

16.REFER TO "PARTITION TYPE SUBSCRIPT KEY" BELOW FOR SYMBOLS USED TO

IDENTIFY ADDITIONAL REQUIREMENTS AND MODIFICATIONS TO BASIC PARTITION

TYPES.

17.PARTITION TYPES DESCRIBE GENERAL REQUIREMENTS FOR PARTITIONS. REFER TO

THE MANUFACTURERS' SPECIFICATIONS AND REQUIREMENTS OF APPLICABLE

TESTING AGENCIES FOR SPECIFICS OF PARTITION CONSTRUCTION.

18.WHERE A CLEAR DIMENSION OR OPENING IS REQUIRED OR NOTED, MEASURE

DIMENSION TO FACE OF PARTITION FINISH.

19.REFER TO INTERIOR FINISH SCHEDULE FOR ALL WALL FINISHES.

GENERAL NOTES FOR INTERIOR PARTITIONS

PARTITION

TYPE

STUD

WIDTH

3 5/8"

PARTITION

WIDTH

4 7/8"

STC

NOTES

NONEA

SCALE:

NON-RATED STUD WALL

1 1/2" = 1'-0"

A

5/8" GYPSUM WALLBOARD

3 5/8" METAL STUDS @ 16" O.C.

5/8" GYPSUM WALLBOARD

ACOUSTIC INSULATION

PARTITION

TYPE

STUD

WIDTH

PARTITION

WIDTH

STC NOTES

B 3 5/8" 4 1/4" 45 NONE

SCALE:

NON-RATED STUD WALL

1 1/2" = 1'-0"

B

B1 2 1/2" 3 3/4" N/A NO INSULATION

PARTITION

TYPE

STUD

WIDTH

3 5/8"

PARTITION

WIDTH

5"

STC

NOTES

NONEF

SCALE:

NON-RATED STUD WALL

1 1/2" = 1'-0"

F

3 5/8" METAL STUDS @ 16" O.C.

5/8" GYPSUM WALLBOARD

ACOUSTIC INSULATION

PARTITION

TYPE

STUD

WIDTH

3 5/8"

PARTITION

WIDTH

4 3/4"

STC

N/A

NOTES

NONEG

SCALE:

NON-RATED STUD WALL

1 1/2" = 1'-0"

G

3 5/8" METAL STUDS @ 16" O.C.

ACOUSTIC INSULATION

CERAMIC TILE

PARTITION

TYPE

CMU

WIDTH

7 5/8"

PARTITION

WIDTH

9 1/8"

STC

N/A

NOTES

NONEC

SCALE:

NON-RATED STUD WALL 8" CMU

1 1/2" = 1'-0"

C

5/8" GYPSUM WALLBOARD

8" X 8" X 16" CMU - 2 CORE

7/8" HAT CHANNEL

2-1/2" METAL STUD

5/8" GYPSUM WALLBOARD

PARTITION

TYPE

STUD

WIDTH

6"

PARTITION

WIDTH

7 1/8"

STC

NOTES

NONED

SCALE:

NON-RATED STUD WALL

1 1/2" = 1'-0"

D

6" METAL STUDS @ 16" O.C.

ACOUSTIC INSULATION

CERAMIC TILE

CERAMIC TILE

PARTITION

TYPE

STUD

WIDTH

PARTITION

WIDTH

STC NOTES

E 3 5/8" 4 7/8" 45 NONE

SCALE:

NON-RATED STUD WALL

1 1/2" = 1'-0"

E

5/8" GYPSUM WALLBOARD

3 5/8" METAL STUDS @ 16" O.C.

ACOUSTIC INSULATION

3 5/8" 5 1/8" 48 NONED1

CERAMIC TILE

EXISTING STUD WALL

ROOM 112

SIDE

ROOM 114

SIDE

EXISTING ACOUSTIC INSULATION

EXISTING 5/8" GYPSUM WALLBOARD

NOTE:

CONTRACTOR TO REMOVE EXISTING FINISH FROM EXISTING

GYPSUM BOARD. PROVIDE NEW SKIM COAT. PREPARE SURFACE

TO RECEIVE NEW FINISH.

6" 7 1/4" 45 NONEA1

5/8" TILE BACKERBOARD

5/8" TILE BACKERBOARD

5/8" TILE BACKER BOARD

5/8" TILE BACKER BOARD

PARTITION

TYPE

CMU

WIDTH

3 5/8"

PARTITION

WIDTH

3 5/8"

STC

N/A

NOTES

NONEH

SCALE:

NON-RATED STUD WALL 4" CMU

1 1/2" = 1'-0"

H

8" X 8" X 16" CMU - 2 CORE

NOTES:

1. SUBSCRIPTS MAY APPLY TO ANY PARTITION TYPES

(TYPE A IS USED ABOVE AS AN EXAMPLE)

CEILING

BOTTOM OF DECK

FLOOR

SUBSCRIPT S

EXTEND TOTAL PARTITION

TO STRUCTURE

S A

WALL FINISH

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

N

AV

AL

A

IR

S

TA

TI

O N

C

KD

B Y:

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

SHEET OF

SA

N

PE

DR

O

S

UI

TE

SA

N

AN

T O

NI

O , T

EX

A S

0-

4-

FA

X

0-

3- 3 1

W

W W

.R

SA

ND

H.

CO

M

TX

C

ER

T.

N O

. F

- 3

AS

S

H O

W N

4/

/ 2

5:

: 3

PM

O F

3 0

L I

FE

S U

PP

O

R T

B U

IL

D

IN

G

0 , D D

P M

/1

6/

5D

FA

-1

0- D

-0

EG TA BW

M

A-100

JO

IN

T R

E S

ER

V E B

AS

E

FO

R

T W

O R

T H , T

X

JH

PA

R

TI

TI

O N

T

YP

E S

D

ET

A I

LS

A D D

I T

IO

N /R

EN

O

VA

TI

O N

SCALE: 1 1/2" = 1'-0"A3 WALL TYPES

SCALE: 3/4" = 1'-0"C4 PARTITION TYPE SUBSCRIPT KEY

SCALE: 1 1/2"=1'-0"

GRAPHIC SCALE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

R

FI

4/

/1

REF.

W D

DW

A-201 B1

A-201 A1

A-201 D1

A-201 C1

3 256 1

2264 SF

AFE LOCKERS

244 SF

BREAK ROOM

199 SF

LOCKER ROOM

203 SF

FLOAT/ GLUE/ TALC

434 SF

TRAINING

329 SF

MOBILITY & STORAGE

288 SF

KIT/VEST ROOM

182 SF

MEN'S RR

101 SF

MEN'S RR

157 SF

NVG/ HMIT

133 SF

MECHANICAL ROOM

100 SF

OFFICE

225 SF

ACDE

94 SF

OFFICE

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1 L1 L1 L1 L1 L1 L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L2

L3 L3 L3 L3 L3

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

586 SF

OPEN OFFICE

1295 SF

SURVIVAL EQUIPMENT

314 SF

CORRIDOR

120 SF

VESTIBULE

339 SF

OFFICE

122 SF

PRINTING STATION

62 SF

UNISEX RR

A-401 C2

L2

L1

L1

L1

L1

L1

L1 L1

L1

L1

L1

C1 A-301

B1 A-301

E

D

A

D

F

D1

A

A

A

A

A

A

A

B

C

B

C

B

B3 A-301 C5

A-301

A-401 D4

A-401 B4

1A

EEEEAAAA

CC

CC

CC

CC

BB

BB

AA

EJ

EJ

DD

B

AB

A

B

A

G

F

F

A

A A

F

A

D1

D1

F

D1

A1

114A

114B

41'-1 3/8" 18'-4" 20'-0" 20'-0" 20'-0" 18'-4"

137'-9 3/8" 1'-0"

16'-1 7/8" 8'-10" 8'-11 1/8"

3'-4" 33'-8 5/8" 67'-9 3/4"

11'-4"

'-4

'-8

'-6

/2

'-1

'-6

/2

'-1

0" 1'

-0

/2

6' -0

/2

6'

-0

5' -1

1" 3'

-4

1' -1

1/

2"

3' -4

1' -3

/8

6' -0

'-8

/4

5/

8"

6' -1

8'

-0

6' -8

8'

-0

6' -8

8'

-0

6' -8

8'

-0

'-2

/8

8'-10" 5'-2" 8'-10" 7'-4 1/2" 3'-4" 2'-11 7/8"

3'-4" 30'-11" 8'-10" 10'-8" 8'-10" 5'-0 7/8"

2'-3" 6'-0" 4'-6" 6'-0" 2'-3" 6'-0"

2'-3"

'-1

1/

2"

'-0

6' -0

2'

-3

'-1

1" 6'

-6

'-0

/4

6' -4

'-2

8' -1

0" 8'

-3

9' -9

9'

-2

/4

9'-3" 6"

17'-5 3/4"

11'-7" 12'-9" 25'-11"

'-1

/4

5'

-1

/8

'-8

'-1

/8

'-1

5/

8" 40'-0 3/8" 17'-5 3/4" 19'-1 7/8" 5'-2" 14'-9 1/4"

1'-1 1/2" 6'-4"

1'-4 3/4" 5'-1 3/4"

9'-3 1/4" 5'-1 3/4" 12'-6"

11'-10 7/8"8'-10 1/8"7'-6 7/8"

99 SF

COMM ROOM

85 SF

ELEC ROOM

C

A-503 D3

A-503 D2

A-503 D1

A-503 D3

Sim

A-503 C5

120A

A-503 C1

A-503 D2

Sim

A-503 C3

DRIVE SIDE

OF OVERHEAD

DOOR

METAL CANOPY

SEE S-101

MAIN

ENTRANCE

CANOPY

A-503 D2

SimA-503 D2

Sim

METAL CANOPY

SEE S-101

METAL CANOPY

SEE S-101

A-503 D2

Sim

A-503 D2

Sim

A-503 D2

Sim

A-503 D2

Sim

'-1

5/

8"

PROVIDE FILLER

PANEL BTW

LOCKER UNITS

L2 L2 L2 L2

L2 L2

EYE WASH

169 SF

AFE LOCKERS

101A

'-0

3'-4" 7'-11 3/8" 3'-4" 6'-11" 3'-4" 3'-0"

GENERAL NOTES:

1. GENERAL CONTRACTOR TO COORDINATE WITH CONTRACTING OFFICER

AND BUILDING USER AND REMOVE, STORE AND PROTECT EXISTING

FURNITURE, CABINETRY AND EQUIPMENT AND RETURN TO DESIGNATED

LOCATION UPON PROJECT COMPLETION.

2. REFER TO SHEET I-101 FOR FURNITURE LAYOUT AND I-102 FOR INTERIOR

DESIGN LAYOUT AND FURNITURE LAYOUT.

3. LOCKERS SHOWN ON ROOM 116 ARE EXISTING AND SHOWN FOR

REFERENCE ONLY. OWNER PROVIDED.

SHEET NOTES:

1. UNLESS OTHERWISE STATED ALL NEW PARTITION WALL TYPES SHALL BE

TYPE 'A'.

2. FOR ALL WALL TYPES IN WET AREAS INCLUDING BUT NOT LIMITED TO

SHOWER, BATHROOM WALL WITH FIXTURE USE TILE WATER BACKER

BOARD IN LIEU OF 5/8" GYPSUM BOARD.

3. INTERIOR SHEATHING FOR EXISTING EXTERIOR WALLS SHALL BE STRIPPED

OF FINISH SURFACE WILL BE CLEANED AND PREPARE TO RECEIVE NEW

FINISH.

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

N

AV

AL

A

IR

S

TA

TI

O N

C

KD

B Y:

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

SHEET OF

SA

N

PE

DR

O

S

UI

TE

SA

N

AN

T O

NI

O , T

EX

A S

0-

4-

FA

X

0-

3- 3 1

W

W W

.R

SA

ND

H.

CO

M

TX

C

ER

T.

N O

. F

- 3

AS

S

H O

W N

4/

/ 2

5:

: 4

PM

O F

3 0

L I

FE

S U

PP

O

R T

B U

IL

D

IN

G

0 , D D

P M

/1

6/

5D

FA

-1

0- D

-0

EG TA BW

M

A-101

JO

IN

T R

E S

ER

V E B

AS

E

FO

R

T W

O R

T H , T

X

JH

AR

C

H

IT

E C

TU

R

AL

F

LO

O R

P

LA

N

A D D

I T

IO

N /R

EN

O

VA

TI

O N

SCALE: 1/8" = 1'-0"B1 ARCHITECTURAL FLOOR PLAN

PLAN NORTH

164 8268

SCALE: 1/8"=1'-0"

GRAPHIC SCALE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

R

FI

4/

/1

1. CONTRACTOR SHALL FIELD VERIFY ALL DOOR AND FRAME

OPENINGS PRIOR TO FABRICATION OF NEW DOORS.

2. ALL GLAZED EXTERIOR DOORS SHALL MEET STANDARDS

AND REQUIREMENTS OF UFC 4-010-01, DOD MINIMUM

ANTITERRORISM STANDARDS FOR BUILDINGS.

3. ALL DOOR LITES AND SIDELITES SHALL BE TEMPERED OR

LAMINATED GLASS. (SAFETY GLASS COMPLYING W/ CPSC

16 CFR 1201).

4. SEE LEGEND OF EXTERIOR COLORS AND FINISHES ON

SHEET A-601 AND LEGEND OF COLORS AND FINISHES ON

SHEET A-601 FOR DOOR AND FRAME FINISH COLORS.

5. PAINT ALL INTERIOR H.M. DOORS AND FRAMES: TP-1

6. PAINT ALL EXTERIOR H.M. DOORS AND FRAMES: TP-1

7. ALL NEW EXTERIOR DOORS SHALL BE INSULATED.

8. FOR SILL TRANSITION, REFER TO A4 DOOR THRESHOLD

DETAILS ON THIS SHEET.

DOOR GENERAL NOTES:

HM HOLLOW METAL

WD SOLID CORE WOOD

ALUM ALUMINUM STOREFRONT

NR NOT RATED

DOOR MATERIAL LEGEND:

B

AS

S

C H

ED

U

LE

D

AS SCHEDULED

A

AS SCHEDULED

AS

S

C H

ED

U

LE

D

FINISH FLOOR

GT

AS

S

C H

ED

U

LE

D

AS SCHEDULED

C

1' -0

D

AS

S

C H

ED

U

LE

D

AS SCHEDULED

AS

S

C H

ED

U

LE

D

AS SCHEDULED

E

8" 1'

-4

2'-2"

LOUVER

F2

7' -4

AS SCHEDULED

F1

AS SCHEDULED

7' -2

FINISH FLOOR

F3

7' -4

AS SCHEDULED

4" 4"2"

EXTERIOR

INSULATED

FINISH SYSTEM

2" CONTINUOUS EPS

DRAINAGE MEDIUM

8" CMU WALL,

EXISTING WALL

WHERE OCCURS

DOOR FRAME AS

SCHED., PAINTED

DOOR AS SCHED.

GROUT FILLBACKER ROD AND

CONTINUOUS

SEALANT, BOTH

SIDES

5/8" GYPSUM WALL

BOARD 3 /12" BATT

INSULATION AND 3

5/8" METAL STUDS AT

16" O.C., WHERE

OCCURS

FOR EXTERIOR WALL ASSEMBLY

SEE FLOOR PLAN

3/ 4"

M

IN

CORNER BEAD,

WHERE OCCURS

CONTINUOUS

FLASHING BY EIFS

MANUFACTURER

6" 5 7/8"

5/8" GYPSUM WALL

BOARD AND MUD J

BEAD, WHERE

OCCURS

CMU HEADER, SEE

STRUCTURAL

LINE OF CMU WALL,

FINISH PER FINISH

SCHEDLE WHERE

EXPOSED

THRU WALL

FLASHING

EXTERIOR

8" CMU WALL,

EXISTING WALL

WHERE OCCURS

DOOR FRAME AS

SCHED., PAINTED

DOOR AS SCHED.

GROUT FILL

BACKER ROD AND

CONTINUOUS SEALANT,

BOTH SIDES

METAL JAMB ANCHOR

(3 PER JAMB)

FO

R

E

XT

ER

IO

R W

AL

L

AS

SE

M

BL

Y

SE

E

FL

O

O R

P

LA

N

3/4" MIN.

CORNER BEAD,

WHERE OCCURS

CAULKING

CONTINUOUS

FLASHING BY EIFS

MANUFACTURER

MUD J BEAD

7/

8"

EXTERIOR

SELF-ADHERED

WATERPROOF

MEMBRANE

FLASHING

SEE DETAIL H2 THIS SHEET

FOR ADDITIONAL WALL

ASSEMBLY NOTES

ABA COMPLIANT

ALUM.

THRESHOLD SET

IN MASTIC

FLOOR FINISH AS

SCHEDULED

EXTERIOR

PAVEMENT -

NON-

SLIPPERY

SURFACE

1/2"

PREMOLDED

JOINT FILLER

TYPICAL FLOOR TRANSITION

@ EXTERIOR HM DOOR

SLOPE

1/ 2"

M

AX

DOOR AS SCHED.

EXTERIOR

STAINLESS STEEL

PAN FLASHING

WITH END DAMS

FULLY SOLDERED

WATERTIGHT

EXTERIOR

INSULATED FINISH

SYSTEM

2" CONTINUOUS EPS

DRAINAGE

MEDIUM

8" CMU WALL,

EXISTING WALL

WHERE OCCURS

ALUMINUM DOOR

FRAME AS SCHEDULED

ALUMINUM DOOR AS

SCHEDULED

BACKER ROD AND

CONTINUOUS

SEALANT, BOTH

SIDES

3 5/8" METAL

STUDS AT 16" O.C.

3 1/2" BATT

INSULATION

5/8" GYPSUM WALL

BOARD

FOR EXTERIOR WALL ASSEMBLY

SEE FLOOR PLAN

CORNER BEAD

CAULKING

CONTINUOUS

FLASHING BY EIFS

MANUFACTURER

5/8" GYPSUM WALL

BOARD AND MUD J

BEAD

CMU HEADER, SEE

STRUCTURAL

EIFS CLOSURE

TRIM

EXTERIOR

2 5/8" 5" 6 7/8"

THRU WALL

FLASHING

3/ 4"

M

IN

ABA COMPLIANT

ALUM. THRESHOLD

SET IN MASTIC

FLOOR FINISH AS

SCHEDULED

EXTERIOR

PAVEMENT -

NON-

SLIPPERY

SURFACE

1/2"

PREMOLDED

JOINT FILLER

TYPICAL FLOOR TRANSITION

@ EXTERIOR ALUMN. DOOR

SLOPE

FRAME AS

SCHEDULED

EXTERIOR

TO DRAIN

STAINLESS STEEL

PAN FLASHING WITH

END DAMS FULLY

SOLDERED

WATERTIGHT

8" CMU WALL,

EXISTING WALL

WHERE OCCURS

ALUMINUM DOOR

FRAME AS

SCHEDULED

ALUMINUM DOOR AS

SCHEDULED

BACKER ROD AND

CONTINUOUS

SEALANT, BOTH

SIDES

FO

R

E

XT

ER

IO

R W

AL

L

AS

SE

M

BL

Y

SE

E

FL

O

O R

P

LA

N

CORNER BEAD

CONTINUOUS

FLASHING BY EIFS

MANUFACTURER

MUD J BEAD

EXTERIOR

5"

7/ 8"

3/4" MIN.

SELF-ADHERED

WATERPROOF

MEMBRANE

FLASHING

SEE DETAIL H1 THIS SHEET

FOR ADDITIONAL WALL

ASSEMBLY NOTES

EXTERIOR

INSULATED FINISH

SYSTEM

2" CONT. EPS

DRAINAGE

MEDIUM

8" CMU WALL

OVERHEAD

DOOR AS

SCHEDULED

5/8" GYPSUM WALL

BOARD, 3 1/2" BATT

INSULATION AND 3

5/8" METAL STUDS

AT 16" O.C.

FOR EXT. WALL ASSEMBLY

SEE FLOOR PLAN

CONTINUOUS

FLASHING BY EIFS

MANUFACTURER

CMU HEADER, SEE

STRUCTURAL

THRU WALL

FLASHING

EXTERIOR

HOOD, SEAL

COMPLETELY

GUIDE BEYOND

SEALANT

8'-0" A.F.F.

INTEGRATED

FRAME ASSEMBLY

WITH DRIP EDGE.

PAINT TO MATCH

ADJACENT FINISH

STEEL ANGLE

BEYOND

1 1

GUIDE BEYOND

OVERHEAD DOOR,

PER SCHED.

FLOOR SEAL

WEATHERSTRIPPING

GALVANIZED STEEL

ANGLE 1"X1"X1/4"CONCRETE

PAVEMENT

1/ 2"

SLOPE

INTEGRATED FRAME

ASSEMBLY BEYOND

EXISTING

CONCRETE

SLAB

STEEL ANGLE BEYOND

TYPICAL FLOOR TRANSITION @

EXTERIOR OVERHEAD DOOR

OVERHEAD DOOR AND

FRAME AS SCHEDULED

BACKER ROD AND

CONTINUOUS SEALANT,

BOTH SIDES

FO

R

E

XT

ER

IO

R W

AL

L

AS

SE

M

BL

Y

SE

E

FL

O

O R

P

LA

N

CONTINUOUS

FLASHING BY EIFS

MANUFACTUREREXTERIOR

SELF-ADHERED

WATERPROOF

MEMBRANE FLASHING

INTEGRATED FRAME

ASSEMBLY. PAINT TO

MATCH ADJACENT FINISH

OVERHEAD DOOR TRACK

WITH INTEGRATED

WEATHER SEAL

GALVANIZED STEEL

ANGLE WITH 3/8" DIA. X

12" W/2" HOOK BOLTS AT

24" O.C. EXTEND SIDE

SIDE LEG TO TOP OF

LINTEL BEAM - COPE AS

REQUIRED WITH

OVERHEAD SUPPORT

SEE DETAIL H3 THIS SHEET

FOR ADDITIONAL WALL

ASSEMBLY NOTES

SCHEDULED DOOR

SCHEDULED FLOOR

FINISH

TRANSITION FLOOR

FINISH BELOW DOOR

TYPICAL FLOOR TRANSITION @ DOOR

A

B

C

F.F.L.

TS - 3; RUBBER TILE TO PORCELAIN TILE

TS - 2; CARPET TO RUBBER TILE

D

TS - 1; CARPET TO PORCELAIN TILE

E

F

TS - 4; RUBBER TILE OR PORCELAIN TILE TO CONCRETE

TS - 5; CARPET TO CONCRETE

MARBLE THRESHOLD AS SCHEDULED

CARPET AS SCHEDULED

TILE AS SCHEDULED

RUBBER TRANSITION STRIP AS SCHEDULED

CARPET AS SCHEDULED

TILE AS SCHEDULED

MARBLE THRESHOLD AS SCHEDULED

TILE AS SCHEDULED

TILE AS SCHEDULED

RUBBER TRANSITION STRIP AS SCHED.

TILE AS SCHEDULED

CONCRETE, FINISHED AS SCHEDULED

RUBBER TRANSITION STRIP AS SCHED.

CARPET AS SCHEDULED

CONCRETE, FINISHED AS SCHEDULED

3/ 8"

M

AX

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

N

AV

AL

A

IR

S

TA

TI

O N

C

KD

B Y:

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

SHEET OF

SA

N

PE

DR

O

S

UI

TE

SA

N

AN

T O

NI

O , T

EX

A S

0-

4-

FA

X

0-

3- 3 1

W

W W

.R

SA

ND

H.

CO

M

TX

C

ER

T.

N O

. F

- 3

AS

S

H O

W N

4/

/ 2

6:

: 4

PM

O F

3 0

L I

FE

S U

PP

O

R T

B U

IL

D

IN

G

0 , D D

P M

/1

6/

5D

FA

-1

0- D

-0

EG TA BW

M

A-602

JO

IN

T R

E S

ER

V E B

AS

E

FO

R

T W

O R

T H , T

X

JH

D O

O R

S C

H E D

U

LE

D

ET

A I

LS

A D D

I T

IO

N /R

EN

O

VA

TI

O N

DOOR SCHEDULE

NO.

DOOR

TYPE

DOOR

FIRE

RATING

FRAME

HARDWARE COMMENTS

SIZE

MATERIAL TYPE MATERIAL

DETAILS

WIDTH HEIGHT THICKNESS HEAD JAMB SILL

101 C 3'-0" 7'-0" 1 3/4" AL NR F1 AL H1 J1 S1 01

101A C 3'-0" 7'-0" 1 3/4" AL NR F1 AL H1 J1 S1 01

102 A 3'-0" 6'-8" 1 3/4" WD NR F1 HM H8 J8 A / TS-1 05

103 A 3'-0" 6'-8" 1 3/4" WD NR F1 HM H8 J8 A / TS-1 07

105 A 3'-0" 7'-0" 1 3/4" WD NR F1 HM H8 J8 A 11

106 A 3'-0" 7'-0" 1 3/4" WD NR F1 HM H8 J8 A / TS-5 12

107 C 3'-0" 7'-0" 1 3/4" AL NR F1 AL H1 J1 S1 01

108 A 3'-0" 7'-0" 1 3/4" WD NR F1 HM H8 J8 A 08

109 A 3'-0" 6'-8" 1 3/4" WD NR F1 HM H8 J8 A 08

110 A 3'-0" 6'-8" 1 3/4" WD NR F1 HM H8 J8 A / TS-2 06

111 A 3'-0" 7'-0" 1 3/4" WD NR F1 HM H8 J8 A 08

112 C 3'-0" 7'-0" 1 3/4" AL NR F1 AL H1 J1 S1 01

113 A 3'-0" 7'-0" 1 3/4" WD NR F2 HM J6 SIM. J6 A / TS-4 08

114 B 3'-0" 7'-0" 1 3/4" WD NR F3 HM J6 SIM. J6 A / TS-4 13 3' - 0" PAIR DOORS

114A A 3'-0" 7'-0" 1 3/4" HM NR F2 HM H2 J2 S2 04

114B D 6'-0" 8'-0" 3/4" STEEL NR - STEEL H3 J3 S3 02 OVER HEAD COILING INSULATED DOOR

116 A 3'-0" 7'-0" 1 3/4" WD NR F1 HM H8 J8 A 09

117 A 3'-0" 7'-0" 1 3/4" WD NR F2 HM J7 SIM. J7 A / TS-5 10

118 A 3'-0" 7'-0" 1 3/4" WD NR F1 HM H8 J8 A / TS-5 08

119 A 3'-0" 7'-0" 1 3/4" HM NR F2 HM H5 J5 S2 04

120 B 3'-0" 7'-0" 1 3/4" WD NR F3 HM H8 J8 A / TS-5 13 3' - 0" PAIR DOORS

120A D 12'-0" 8'-0" 3/4" STEEL NR - STEEL H4 J4 S3 SIM. 02 OVER HEAD COILING INSULATED DOOR

121 E 3'-0" 7'-0" 1 3/4" HM NR F2 HM H2 J2 S2 04

122 A 3'-0" 7'-0" 1 3/4" HM NR F2 HM H2 J2 S2 04

123 A 3'-0" 7'-0" 1 3/4" HM NR F2 HM H2 J2 S2 03

SCALE: 1/4" = 1'-0"C4 DOOR TYPES

SCALE: 1/4" = 1'-0"D3 FRAME TYPES

SCALE: 1 1/2" = 1'-0"C2 EXTERIOR HEAD DETAIL(C2)

SCALE: 1 1/2" = 1'-0"B2 EXTERIOR JAMB DETAIL(J2)

SCALE: 1 1/2" = 1'-0"A2 SILL DETAIL(S2)

SCALE: 1 1/2" = 1'-0"C1 EXTERIOR HEAD DETAIL(H1)

SCALE: 1 1/2" = 1'-0"A1 SILL DETAIL(S1)

SCALE: 1 1/2" = 1'-0"B1 EXTERIOR JAMB DETAIL(J1)

SCALE: 1 1/2" = 1'-0"C3 EXTERIOR HEAD DETAIL(H3)

SCALE: 1 1/2" = 1'-0"A3 SILL DETAIL(S3)

SCALE: 1 1/2" = 1'-0"B3 EXTERIOR JAMB DETAIL(J3)

SCALE: 1 1/2"=1'-0"

SCALE: 3" = 1'-0"A4 DOOR THRESHOLD DETAILS

6"6"

SCALE: 3"=1'-0"

04 2

GRAPHIC SCALES

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

R

FI

4/

/1

CONTINUOUS FLASHING BY

EIFS MANUFACTURER

EXTERIOR

SELF-ADHERED WATERPROOF

MEMBRANE FLASHING

INTEGRATED FRAME

ASSEMBLY. PAINT TO

MATCH ADJACENT FINISH

OVERHEAD DOOR TRACK

WITH INTEGRATED

WEATHER SEAL

GALVANIZED STEEL ANGLE EXTEND

SIDE SIDE LEG TO TOP OF LINTEL BEAM

- COPE AS REQUIRED WITH OVERHEAD

SUPPORT

EXTERIOR INSULATED

FINISH SYSTEM

2" CONTINUOUS EPS

5/8" SUBSTRATE SHEATHING

OVER 7/8" METAL HAT

CHANNELS

DRAINAGE MEDIUM

EXISTING METAL PANEL

EXISTING METAL PURLINS

5/8" GYPSUM BOARD

3 1/2" BATT. INSULATION

3 5/8" METAL STUDS

CONTINUOUS SEALANT

AND BACKER ROD

FOR EXTERIOR WALL ASSEMBLY

SEE FLOOR PLAN

EXTERIOR

CONTINUOUS FLASHING BY

EIFS MANUFACTURER

EXTERIOR

SELF-ADHERED WATERPROOF

MEMBRANE FLASHING

INTEGRATED FRAME

ASSEMBLY. PAINT TO

MATCH ADJACENT FINISH

OVERHEAD DOOR TRACK

WITH INTEGRATED

WEATHER SEAL

GALVANIZED STEEL ANGLE BEYOND

EXTERIOR INSULATED

FINISH SYSTEM

2" CONTINUOUS

EPS

5/8" SUBSTRATE SHEATHING

OVER 7/8" METAL HAT

CHANNELS

DRAINAGE MEDIUM

EXISTING METAL PANEL

EXISTING METAL PURLINS

5/8" GYPSUM BOARD

3 1/2" BATT. INSULATION

3 5/8" METAL STUDS

CONTINUOUS SEALANT

AND BACKER ROD

FOR EXTERIOR WALL ASSEMBLY

SEE FLOOR PLAN

EXISTING STEEL

CHANNEL

HOOD, SEAL COMPLETELY

CONTINOUS SEALANT

8'-0" A.F.F.

GUIDE BEYOND

EXTERIOR

INSULATED

FINISH SYSTEM

2" CONTINUOUS

EPS

DRAINAGE

MEDIUM

DOOR FRAME AS

SCHED., PAINTED

DOOR AS SCHED.

GROUT FILLBACKER ROD AND

CONTINUOUS

SEALANT, BOTH

SIDES

CONTINUOUS

FLASHING BY EIFS

MANUFACTURER

STEEL CHANNEL,

SEE STRUCTURAL

THRU WALL

FLASHING

EXTERIOR

5/8" GYPSUM BOARD OVER 3

5/8" METAL STUDS AT 16" O.C.

3 1/2" BATT. INSULATION

EXISTING METAL PANEL

5/8" SUBSTRATE SHEATHING

OVER 7/8" METAL HAT CHANNELS

EXISTING METAL PURLIN

EXISTING SPRAYED

INSULATION

EIFS CLOSURE

TRIM

FO

R

E

XT

ER

IO

R W

AL

L

AS

S E

M

BL

Y

SE

E

FL

O

O R

P

LA

N

EXTERIOR

SEE DETAIL H5 THIS SHEET

FOR ADDITIONAL WALL

ASSEMBLY NOTES

3/4" MIN.

3/

4"

DOOR FRAME AS

SCHED., PAINTED

DOOR AS SCHED.

GROUT FILL

BACKER ROD AND

CONTINUOUS SEALANT,

BOTH SIDES

METAL JAMB ANCHOR

(3 PER JAMB)

CORNER BEAD

CAULKING

CONTINUOUS

FLASHING BY EIFS

MANUFACTURER

MUD J BEAD

SELF-ADHERED

WATERPROOF

MEMBRANE

FLASHING

EIFS CLOSURE

TRIM

STEEL CHANNEL,

SEE STRUCTURAL

1/ 2"

2"

SOUND ATTENUATION IF INDICATED,

SEE A-100 FOR PARTITION PLAN

5/8" GYPSUM BOARD

PROVIDE METAL STUD

FRAMING AS REQUIRED

SEALANT, TYP.

EACH SIDE

HOLLOW METAL FRAME

DOOR, AS SCHEDULED

FOR PARTITION TYPE

SEE FLOOR PLAN

1/2" 2"

SOUND ATTENUATION IF INDICATED,

SEE A-100 FOR PARTITION PLAN

5/8" GYPSUM BOARD

PROVIDE METAL STUD

FRAMING AS REQUIRED

SEALANT, TYP.

EACH SIDE

HOLLOW METAL FRAME

DOOR, AS SCHEDULED

JAMB ANCHORS, MIN 3 PER JAMB

FO

R

P

AR

TI

TI

O N

T

YP

E

SE

E

FL

O

O R

P

LA

N

ROOM 112

SIDE

ROOM 113 & 114

SIDE

EXISTING CLAY

TILE WALL

DOOR FRAME AS

SCHED., PAINTED

DOOR AS SCHED.

GROUT FILL

BACKER ROD AND

CONTINUOUS SEALANT,

BOTH SIDES

METAL JAMB ANCHOR

(3 PER JAMB)

CORNER BEAD

CAULKING

CONTINUOUS

FLASHING

MUD J BEAD

1/

4" SELF-ADHERED

WATERPROOF

MEMBRANE FLASHING

5/8" GYPSUM BOARD

OVER 7/8" HAT CHANNEL

5/8" GYPSUM BOARD

OVER 3 5/8" METAL

STUD AT 16" O.C.

FO

R

P

AR

TI

TI

O N

T

YP

E

SE

E

FL

O

O R

P

LA

N

ROOM 120

SIDE

ROOM 117

SIDE

EXISTING CLAY

TILE WALL

DOOR FRAME AS

SCHED., PAINTED

GROUT FILL

BACKER ROD AND

CONTINUOUS SEALANT,

BOTH SIDES

METAL JAMB ANCHOR

(3 PER JAMB)

CORNER BEAD

CAULKING

CONTINUOUS

FLASHING

MUD J BEAD

1/

8"

SELF-ADHERED

WATERPROOF

MEMBRANE

FLASHING

5/8" GYPSUM BOARD

OVER 3 5/8" METAL

STUDS AT 16" O.C.

5/8" GYPSUM BOARD

OVER 3 5/8" METAL

STUD AT 16" O.C.

FO

R

P

AR

TI

TI

O N

T

YP

E

SE

E

FL

O

O R

P

LA

N

EXISTING 2"± SPRAYED

ON INSULATION

3 1/2" BATT INSULATION

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

N

AV

AL

A

IR

S

TA

TI

O N

C

KD

B Y:

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

SHEET OF

SA

N

PE

DR

O

S

UI

TE

SA

N

AN

T O

NI

O , T

EX

A S

0-

4-

FA

X

0-

3- 3 1

W

W W

.R

SA

ND

H.

CO

M

TX

C

ER

T.

N O

. F

- 3

AS

S

H O

W N

4/

/ 2

6:

: 0

PM

O F

3 0

L I

FE

S U

PP

O

R T

B U

IL

D

IN

G

0 , D D

P M

/1

6/

5D

FA

-1

0- D

-0

EG SS A

pp ro ve r

A-603

JO

IN

T R

E S

ER

V E B

AS

E

FO

R

T W

O R

T H , T

X

JH

D O

O R

D

ET

AI

LS

A D D

I T

IO

N /R

EN

O

VA

TI

O N

SCALE: 1 1/2" = 1'-0"B1 EXTERIOR JAMB DETAIL(J4)

SCALE: 1 1/2" = 1'-0"D1 EXTERIOR HEAD DETAIL(H4)

SCALE: 1 1/2"=1'-0"

GRAPHIC SCALE

SCALE: 1 1/2" = 1'-0"D2 EXTERIOR HEAD DETAIL(H5)

SCALE: 1 1/2" = 1'-0"B2 EXTERIOR JAMB DETAIL(J5)

SCALE: 1 1/2" = 1'-0"A1 INTERIOR HEAD DETAIL(H8)

SCALE: 1 1/2" = 1'-0"A2 INTERIOR JAMB DETAIL(J8)

SCALE: 1 1/2" = 1'-0"D4 INTERIOR JAMB DETAIL(J6)

HEAD SIMILAR

SCALE: 1 1/2" = 1'-0"B4 INTERIOR JAMB DETAIL(J7)

HEAD SIMILAR

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

R

FI

4/

/1

REF.

W D

DW

3 256 1

2264 SF

AFE LOCKERS

244 SF

BREAK ROOM

199 SF

LOCKER ROOM

203 SF

FLOAT/ GLUE/ TALC

434 SF

TRAINING

329 SF

MOBILITY & STORAGE

288 SF

KIT/VEST ROOM

182 SF

MEN'S RR

101 SF

MEN'S RR

157 SF

NVG/ HMIT

135 SF

MECHANICAL ROOM

100 SF

OFFICE

225 SF

ACDE

94 SF

OFFICE

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1 L1 L1 L1 L1 L1 L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L2

L3 L3 L3 L3 L3

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

L1

586 SF

OPEN OFFICE

1295 SF

SURVIVAL EQUIPMENT

314 SF

CORRIDOR

120 SF

VESTIBULE

339 SF

OFFICE

122 SF

PRINTING STATION

62 SF

UNISEX RR

L2

L1

L1

L1

L1

L1

L1 L1

L1

L1

L1

E

D

A

B

C

CONC-1

CPT-1

PT-F1

PT-F2

PT-F3

102 SF

COMM ROOM

86 SF

ELEC ROOM

5' -6

33'-3 3/8"

169 SF

AFE LOCKERS

101A

POLISHED CONCRETE

CG

CG

CG

CG

CG

1. CONTRACTOR TO CLEAN AND REMOVE ALL FINISHES FROM

EXISTING CONCRETE FLOOR PRIOR TO PLISHING EXISTING

FLOOR. PATCH AND REPAIR ALL DAMAGED CONCRETE

FLOORING PRIOR TO PLISHING.

2. PROVIDE BUILDING SIGNAGE SYSTEM SEE

SPECIFICATIONS.

GENERAL NOTES:

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

N

AV

AL

A

IR

S

TA

TI

O N

C

KD

B Y:

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

SHEET OF

SA

N

PE

DR

O

S

UI

TE

SA

N

AN

T O

NI

O , T

EX

A S

0-

4-

FA

X

0-

3- 3 1

W

W W

.R

SA

ND

H.

CO

M

TX

C

ER

T.

N O

. F

- 3

AS

S

H O

W N

4/

/ 2

4:

: 5

PM

O F

3 0

L I

FE

S U

PP

O

R T

B U

IL

D

IN

G

0 , D D

P M

/1

6/

5D

FA

-1

0- D

-0

EG TA BW

M

I-101

JO

IN

T R

E S

ER

V E B

AS

E

FO

R

T W

O R

T H , T

X

JH

FL

O

O R

IN

G

P

LA

N

A D D

I T

IO

N /R

EN

O

VA

TI

O N

SCALE: 1/8" = 1'-0"

A-201

B1 FLOORING PLAN

164 8268

SCALE: 1/8"=1'-0"

GRAPHIC SCALE

PLAN NORTH

LEGEND:

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

R

FI

4/

/1

CG: STAINLESS STEEL CORNER GUARD

File details come from the government source that posted it.