Limited Lead-Based Paint Sampling Report
301st Life Support Building 1630
SW Corner of Carswell Avenue and G Street
Naval Air Station Fort Worth Joint Reserve Base
Fort Worth, Texas
November 26, 2014
Terracon Project No. 95147282
Prepared for:
CEMS Engineering, Inc.
P.O. Box 1680
Ladson, South Carolina 29456
Prepared by:
Terracon Consultants, Inc.
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Project Objective
2.0 BUILDING DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Site Limitations
3.2 Methodology and Analysis
4.0 REGULATORY OVERVIEW
5.0 FINDINGS AND RECOMMENDATIONS
6.0 GENERAL COMMENTS
APPENDIX A IDENTIFIED LEAD-CONTAINING PAINT
APPENDIX B LAB RESULTS
APPENDIX C CERTIFICATIONS
Responsive ■ Resourceful ■ Reliable 1
LIMITED LEAD-BASED PAINT SAMPLING REPORT
301st Life Support Building 1630
SW Corner of Carswell Avenue and G Street
Naval Air Station Fort Worth Joint Reserve Base
Terracon Project No. 95147282
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted limited lead-based paint (LBP) paint chip sampling at the 301st Life Support Building 1630 located on the southwest corner of
Carswell Avenue and G Street at the Naval Air Station Fort Worth Joint Reserve Base in
Fort Worth, Texas. The LBP sampling was conducted on November 19, 2014 by Phillip G.
Fronczek, a State of Texas certified Lead Risk Assessor. The LBP sampling was performed in general accordance with Terracon Proposal No. P95140769 dated November
10, 2014.
1.1 Project Objective
The objective of the LBP sampling was to identify accessible representative LBP associated with the building. The LBP sampling was limited to readily observable and accessible surfaces. It should be understood that this limited LBP sampling is not considered to be comprehensive in nature, and the results are not intended to be used to determine lead hazards, develop abatement plans, or prepare detailed cost estimates for abatement. Accessible materials which have not been specifically evaluated should be tested prior to disturbance of the material. Based on information provided by the client, the building is proposed for renovation.
Regulatory agencies (HUD, TDSHS) have defined LBP as a paint or other surface coating that contain >5,000 parts per million (ppm) of lead or more than 0.5% of lead by weight for buildings that meet the definition of target housing. The Occupational Safety and Health
Administration (OSHA) define LBP as a paint which contains lead, regardless of the concentration. Due to the nature of the site the OSHA regulations will apply to the construction and/or demolition activities.
2.0 BUILDING DESCRIPTION
The 301st Life Support Building 1630 is a single-story structure constructed in 1942, with a mechanical room addition constructed on the southwest side of the original building in
1950, and a mobility storage addition constructed on the west side of the original building between 1989 and 2007. The building is constructed on a concrete slab foundation and measures approximately 6,360 square-feet with a gabled metal roof.
Lead-Based Paint Sampling NASJRB - 301st Life Support Building 1630 ■ Fort Worth, Texas November 26, 2014 ■ Terracon Project No. 95147282
Responsive ■ Resourceful ■ Reliable 2
The exterior walls of the building consist of exterior insulated finish system (EIFS) over concrete masonry unit (CMU) block. The interior of the building consists of storage rooms, training rooms, a locker room, offices, restrooms and hallways. The interior walls consist of painted drywall and painted CMU block. The floors consist of unfinished concrete, carpet, vinyl floor tile, and ceramic tile. The ceilings consist of painted drywall and ceiling tile suspended from the drywall upper ceiling. A CMU block wall is present behind the sheetrock on the south wall of the locker room.
3.0 FIELD ACTIVITIES
The LBP sampling was conducted by Mr. Phillip G. Fronczek, a TDSHS certified Lead Risk
Assessor (Certification No. 2070985). A copy of Mr. Fronczek’s certification is attached as
Appendix D.
3.1 Site Limitations
It should be noted that suspect LBP, other than those identified during the sampling, may exist within the building and/or on the building exterior. It should be understood that this limited LBP sampling is not considered to be comprehensive in nature, and the results are not intended to be used to determine lead hazards, develop abatement plans, or prepare detailed cost estimates for abatement. Accessible materials which have not been specifically evaluated should be tested prior to disturbance of the material. If suspect LBP is identified during the renovation process, those materials should be assumed to LBP until testing can be performed to determine if lead is present in the paint. At the request of the client, no sampling was conducted in the mobility storage addition to the building.
3.2 Methodology and Analysis
The LBP paint chip sampling was conducted by scraping approximately 2 square inches of paint from the supporting substrate. Eighteen (18) paint chip samples of were collected from various concrete masonry unit (CMU) block walls, metal structural columns and trusses, drywall walls and ceilings, a metal door, a metal door frame, a wood door frame, a concrete mechanical equipment pad, a metal electrical box, and the side of the concrete foundation on the exterior of the building. The samples were submitted to Environmental
Hazards Services, L.L.C. of Richmond, VA, a National Environmental Laboratory
Accreditation Program (NELAP) certified (Certificate No. T104704248-11-3) and AIHA accredited (Lab ID: 100420) accredited laboratory. The analysis was performed by Flame
Atomic Absorption Spectrophotometry, EPA method (EPA SW846 7000B). The limit of detection (LOD) for this analytical method ranges from <32 ppm to <130 ppm based on the weight of the sample. Sample results reported below the LOD may contain lead at a
Responsive ■ Resourceful ■ Reliable 3 concentration below the analytically defined LOD. A summary of the lead based paint samples and analysis is included in Appendix B.
No materials were assumed to be LBP. Any inaccessible areas that contain painted surfaces should be tested when access permits or should be assumed to be positive for Lead-Based
Paint.
4.0 REGULATORY OVERVIEW
The State of Texas has established the Texas Environmental Lead Reduction Rules
(TELRR) to establish the means to control and minimize public exposure to lead by regulating lead-based paint activities in target housing and child-occupied facilities. The
TELRR contains procedures and requirements for the accreditation of lead training providers, procedures and requirements for the certification of individuals and firms engaged in lead-based paint activities and standards for performing such activities in target housing and child-occupied facilities. The TELRR also requires that all lead-based paint activities in target housing and child-occupied facilities be performed by certified individuals.
As a point of reference, regulatory agencies (HUD, TDSHS) have defined LBP as a paint or other surface coating that contain >5,000 parts per million (ppm) of lead or more than
0.5% of lead by weight for buildings that meet the definition of target housing. OSHA, however, defines LBP as a paint which contains lead, regardless of the concentration.
The OSHA Lead Standard for Construction (29 CFR 1926.62) applies to construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included. The lead-in-construction standard applies to any detectable concentration of lead in paint. OSHA considers paint containing any level of lead above the analytical method detection limit a potential hazard which should be communicated to any employees or contractors who may disturb the materials in the course of their assigned work.
5.0 FINDINGS AND RECOMMENDATIONS
A total of 18 paint chip samples were collected and twelve (12) samples were determined to contain detectible concentration of lead. A summary of the components tested, location of the sample, and results are provided in Appendix A.
Responsive ■ Resourceful ■ Reliable 4
The following materials were determined to contain detectible concentrations of lead:
Interior
White paint on CMU block walls in the original building
White paint on metal structural columns
White paint on perimeter drywall walls
Gray paint on concrete mechanical equipment pad
White paint on metal structural truss
White paint on metal electrical box
Exterior
Tan paint on side of concrete foundation (appears to be present behind EIFS as well)
Samples of the following materials were determined to be below the limit of detection
(LOD) which ranged from <39 to <340 ppm:
Interior
Blue paint on metal doorframes
White paint on CMU block walls in the mechanical room addition
White paint on interior drywall walls
Exterior
Brown paint on metal doors
Brown paint on wood doorframes
The renovation activities conducted in the 301st Life Support Building 1630 will be subject to OSHA regulations (29 CFR 1926.62 – Lead Exposure in Construction). The OSHA regulation defines specific training requirements, engineering controls and working practices for construction personnel subject to this standard. There are also federal and state regulations, which require characterization of demolition debris to determine the proper disposal procedures.
The possibility exists that LBP coated surfaces may be hidden from sight or in inaccessible locations, or the homogeneous construction areas identified may not be homogeneous.
Responsive ■ Resourceful ■ Reliable 5
6.0 GENERAL COMMENTS
This LBP sampling was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our sampling of the building. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by CEMS Engineering, Inc.
for specific application to their project as discussed. This report is not a bidding document.
Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
IDENTIFIED LEAD CONTAINING PAINT
301st Life Support Building 1630
SW Corner of Carswell Avenue and G Street
Naval Air Station Fort Worth Joint Reserve Base
Fort Worth, Texas
Terracon Project No. 95147282
Sample Number
Sample Location
Component Lead
Concentration1
(ppm)
Survival
Equipment Room
White paint on CMU block walls in the original building 25,000
Survival
Equipment Room
White paint on CMU block walls in the original building 6,300
Survival
Equipment Room
White paint on metal structural columns 89,000
5 Hallway White paint on perimeter drywall walls 50
Exterior East
Wall
Tan paint on side of concrete foundation (appears to be present behind EIFS as well)
2,300
Exterior North
Wall
Tan paint on side of concrete foundation (appears to be present behind EIFS as well)
Exterior
Southwest Wall
Tan paint on side of concrete foundation (appears to be present behind EIFS as well)
Mechanical
Room Gray paint on concrete equipment pad 3,500
14 Locker Room White paint on CMU block wall (within sheetrock wall)
16 Locker Room White paint on sheetrock ceiling 64
Survival
Equipment Room
White paint on metal structural truss 7,800
Survival
Equipment Room
White paint on metal electrical box 3,600
1OSHA Lead Standard for Construction (29 CFR 1926.62) applies to any detectable concentration lead in paint. Demolition or renovation of the listed components will be subject to the OSHA Lead Standard for Construction.
For comparison purposes the US Environmental Protection Agency (EPA) action level for lead-based painted surfaces is 5,000 part per million for residential/target housing.
The OSHA Lead Standard for Construction (29 CFR 1926.62) applies to construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included.
APPENDIX B
LAB RESULTS
Analysis Report
Client:
Project/Test Address:
Terracon - Ft. Worth
7469 Whitepine Rd
Telephone: 800.347.4010
Richmond, VA 23237
Environmental Hazards Services, L.L.C.
NASJRB Building 1630; Fort Worth, Texas
Client Number:
45-5814
Fax Number:
817-268-8602Laboratory Results
Analyzed Date:
Client Sample Number
Lab Sample Number
Pb (ug/g) ppm
Lead Paint Chip
11/25/2014
11/20/2014
14-11-02361
Reported Date:
Received Date:
Report Number:
2501 E. Loop 820, North Ft. Worth, TX 76118
Narrative
ID
11/24/2014
Collection Location % Pb by Wt.
11/19/2014Collection Date:
114-11-02361-001 SV EQUIP 25000 2.5
214-11-02361-002 SV EQUIP 6300 0.63
314-11-02361-003 SV EQUIP 89000 8.9
414-11-02361-004 L03LOCKER RM <340 <0.034
514-11-02361-005 HALLWAY 50 0.0050
614-11-02361-006 HALLWAY <46 <0.0046
714-11-02361-007 EXT EAST 2300 0.23
814-11-02361-008 EXT NORTH 140 0.014
914-11-02361-009 EXT SW 49 0.0049
1014-11-02361-010 L03EXT SOUTH <220 <0.022
1114-11-02361-011 EXT SOUTH <39 <0.0039
Page 2of1
1214-11-02361-012 L03MECH <130 <0.013
1314-11-02361-013 MECH 3500 0.35
1414-11-02361-014 LOCKER RM 150 0.015
1514-11-02361-015 L04LOCKER RM <41 <0.0041
1614-11-02361-016 L04LOCKER RM 64 0.0064
1714-11-02361-017 SV EQUIP 7800 0.78
1814-11-02361-018 SV EQUIP 3600 0.36
Deborah Britt
QA/QC Clerk
Method: EPA SW846 7000B
The HUD lead guidelines for lead paint chips are 0.50% by Weight, 5000 ppm, or 1.0 mg/cm². The Reporting Limit (RL) is 10.0 ug Total Pb.
Paint chip area and results are calculated based on area measurements determined by the client. All internal quality control requirements associated with this batch were met, unless otherwise noted.
LEGEND Pb= lead ug = microgram ppm = parts per million ug/g = micrograms per gram Wt. = weight
Reviewed By Authorized Signatory:
L03: Sample submitted was less than the recommended amount. A minimum of 0.1 grams should be submitted.
L04: Sample contains substantial amounts of substrate which may affect the calculated results with units of ppm and % by weight.
Sample Narratives:
TX T104704248-07TXAccreditation #:
The condition of the samples analyzed was acceptable upon receipt per laboratory protocol unless otherwise noted on this report. Results represent the analysis of samples submitted by the client. Sample location, description, area, etc., was provided by the client. Results reported above in mg/cm3 are calculated based on area supplied by client. This report shall not be reproduced except in full, without the written consent of the Environmental Hazards Service, L.L.C. California Certification #2319 NY ELAP #11714.
Report Number:
Environmental Hazards Services, L.L.C
Project/Test Address:
Client Number: 14-11-02361
NASJRB Building 1630; Fort Worth, Texas
45-5814
Collection LocationClient Sample Number
Lab Sample Number
% Pb by Wt.
Narrative
ID
Pb (ug/g) ppm
Page 2of2
APPENDIX C
CERTIFICATIONS
AIHA Laboratory Accreditation Programs, LLC acknowledges that
Environmental Hazards Services, LLC 7469 White Pine Road, Richmond, VA 23237
Laboratory ID: 100420 along with all premises from which key activities are performed, as listed above, has fulfilled the requirements of the AIHA Laboratory Accreditation Programs (AIHA-LAP), LLC accreditation to the ISO/IEC 17025:2005 international standard, General Requirements for the Competence of Testing and Calibration Laboratories in the following:
LABORATORY ACCREDITATION PROGRAMS
INDUSTRIAL HYGIENE Accreditation Expires: 05/01/2016 ENVIRONMENTAL LEAD Accreditation Expires: 05/01/2016 ENVIRONMENTAL MICROBIOLOGY Accreditation Expires: 05/01/2016 FOOD Accreditation Expires:
UNIQUE SCOPES Accreditation Expires:
Specific Field(s) of Testing (FoT)/Method(s) within each Accreditation Program for which the above named laboratory maintains accreditation is outlined on the attached Scope of Accreditation. Continued accreditation is contingent upon successful on-going compliance with ISO/IEC 17025:2005 and AIHA-LAP, LLC requirements. This certificate is not valid without the attached Scope of Accreditation. Please review the AIHA- LAP, LLC website (www.aihaaccreditedlabs.org) for the most current Scope.
Gerald Schultz, CIH Chairperson, Analytical Accreditation Board
Cheryl O. Morton Managing Director, AIHA Laboratory Accreditation Programs, LLC
Revision 14: 03/26/2014 Date Issued: 04/30/2014 http://www.aihaaccreditedlabs.org/
Effective: 03/12/2013 100420_Scope_ELLAP_2014_04_30
AIHA Laboratory Accreditation Programs, LLC
SCOPE OF ACCREDITATION
Environmental Hazards Services, LLC Laboratory ID: 100420 7469 White Pine Road, Richmond, VA 23237 Issue Date: 04/30/2014
The laboratory is approved for those specific field(s) of testing/methods listed in the table below. Clients are urged to verify the laboratory’s current accreditation status for the particular field(s) of testing/Methods, since these can change due to proficiency status, suspension and/or withdrawal of accreditation.
The EPA recognizes the AIHA-LAP, LLC ELLAP program as meeting the requirements of the National Lead Laboratory Accreditation Program (NLLAP) established under Title X of the Residential Lead-Based Paint Hazard Reduction Act of 1992 and includes paint, soil and dust wipe analysis. Air analysis is not included as part of the NLLAP.
Environmental Lead Laboratory Accreditation Program (ELLAP)
Initial Accreditation Date: 03/01/1999
A complete listing of currently accredited Environmental Lead laboratories is available on the AIHA-LAP, LLC website at: http://www.aihaaccreditedlabs.org
Field of Testing (FoT) Method Method Description (for internal methods only)
Paint
ASTM E-1645
ASTM E1979-12
EPA SW-846 3050B
EPA SW-846 6010C
EPA SW-846 7000B
Soil
ASTM E-1645
ASTM E1979-12
EPA SW-846 3050B
EPA SW-846 6010C
EPA SW-846 7000B
Settled Dust by Wipe
ASTM E1979-12
EPA SW-846 3050B
EPA SW-846 6010C
EPA SW-846 7000B
Airborne Dust
ASTM E1979-12
EPA SW-846 7000B
NIOSH 7082
NIOSH 7300 Modified
Composited Wipes ASTM E1979-12 Modified
EPA SW-846 6010C
EPA SW-846 7000B
http://www.aihaaccreditedlabs.org/
| Final_14-11-02361.PDF |
| File1058590.pdf |
| page 2 |
| File1056919.pdf |
| page 2 |
| Certs.pdf |
| LeadTC_Appendicies.pdf |
| Lead Risk Assessor Lead Risk Assessor |
| TABLE OF CONTENTS |
| APPENDICES |
| HUD LEAD RISK ASSESSMENT AND |
| LIMITED LEAD BASED PAINT INSPECTION REPORT |
| Terracon Project No. 95107077B |
| 1.0 INTRODUCTION |
| 3.0 REGULATIONS |
| 4.0 SAMPLING AND TESTING |
| 4.2 METHODOLOGY AND DUST/SOIL SAMPLING RESULTS |
| 4.3 XRF INSTRUMENTATION |
| 4.4 XRF RESULTS |
| GENERAL COMMENTS |
| Lab Results_Oak Timber.pdf |
| File318471.pdf |
| page 2 |
| page 3 |
| File317572.pdf |
| page 2 |
| Lab Results_Oak Timber.pdf |
| File318471.pdf |
| page 2 |
| page 3 |
| File317572.pdf |
| page 2 |
| Dust Wipe Results.PDF |
| File611438.pdf |
| page 2 |
| page 3 |
| File611351.pdf |
| page 2 |
| Final_12-10-03187.PDF |
| File686670.pdf |
| page 2 |
| page 3 |
| File686056.pdf |
| page 2 |
| Final_12-12-02235.PDF |
| File715897.pdf |
| page 2 |
| page 3 |
| File715223.pdf |
| page 2 |
| EHS Lead 2016 AIHA.pdf |
| Environmental Hazards Services, LLC |
| 7469 White Pine Road, Richmond, VA 23237 |
| Laboratory ID: 100420 |
| LABORATORY ACCREDITATION PROGRAMS |
File details come from the government source that posted it.