PROJECT LOCATION
PROJECT LOCATION
PROJECT LOCATION
No. 29581
S
OU
TH
CAROL IN
A
B
R A D L E Y W. M I N O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G
I N E E R
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N A
V A
L A
IR
S
T A
T
IO
N
C K
D B
Y x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
I T E
C T
U R
E C
E M
S P ro je c t N o
N
P ro je c t M a n a g e r:
B ra d M in o r
301ST FIGHTER WING
NAVAL AIR STATION, FORT WORTH JOINT
RESERVE BASE, TX
CONTRACT NUMBER: FA6643-10-D-0002
TASK ORDER: 5D03
N O
N E
09/16/2015
/1
/2
:2 :5
A
M
L
IF
E S
U P
P O
R T
B U
IL
D
IN
G
D D
P M
/1 /2
D
F A
-1
-D
-0
B D
M
B D
M
B W
M
G-001
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
X B
W M
C O
V E
R S
H E
E T
A D
D
IT
IO
N
/R E
N O
V A
T
IO
N O
F
ADDITION/RENOVATION OF 301 LIFE
SUPPORT BUILDING 1630, DDPM 120002
SEPTEMBER 16, 2015
FINAL SUBMITTAL
# OF
TOTAL SHEET NO. SHEET TITLE
MECHANICAL
62 M-001 GENERAL NOTES & LEGENDS
63 MD101 MECHANICAL DEMOLITION PLAN
64 M-101 MECHANICAL NEW WORK PLAN
65 M-501 MECHANICAL DETAILS
66 M-502 MECHANICAL DETAILS
67 M-601 MECHANICAL SCHEDULES
68 M-602 MECHANICAL SCHEDULES
69 M-701 CONTROLS & OPERATION
ELECTRICAL
70 E-001 ELECTRICAL GENERAL NOTES & LEGENDS
71 ES101 ELECTRICAL DEMOLITION SITE PLAN
72 ES102 ELECTRICAL NEW WORK SITE PLAN
73 ED101 ELECTRICAL DEMOLITION PLAN
74 E-101 NEW WORK POWER PLANS
75 E-102 NEW WORK LIGHTING PLAN
76 E-103 NEW WORK COMMUNICATIONS PLANS
77 E-501 LIGHTING SCHEDULE & DETAILS
78 E-502 ELECTRICAL DETAILS
79 E-601 ELECTRICAL PANEL SCHEDULES
80 E-602 ELECTRICAL PANEL SCHEDULES
81 E-603 ELECTRICAL RISER DIAGRAMS
82 E-604 COMMUNICATIONS RISER DIAGRAM &
DETAILS
83 E-701 LIGHTNING PROTECTION NEW WORK PLAN
84 E-702 LIGHTNING PROTECTION DETAILS
Grand total: 84
# OF
TOTAL SHEET NO. SHEET TITLE
GENERAL
1 G-001 COVER SHEET
CIVIL
2 VF101 EXISTING CONDITIONS SURVEY
3 CD101 SITE DEMOLITION PLAN
4 CI101 CIVIL IMPROVEMENTS PLAN
5 CG101 CIVIL SEDIMENT AND EROSION CONTROL
PLAN
6 C-501 CIVIL DETAILS
7 C-502 CIVIL DETAILS
LANDSCAPE
8 L-101 LANDSCAPE PLAN
STRUCTURAL
9 S-001 STRUCTURAL GENERAL NOTES
10 S-002 STRUCTURAL GENERAL NOTES
11 SD101 STRUCTURAL DEMOLITION PLANS
12 SD201 STRUCTURAL DEMOLITION ELEVATIONS
13 S-101 STRUCTURAL NEW WORK FOUNDATION
PLAN
14 S-102 STRUCTURAL NEW WORK ROOF FRAMING
PLANS
15 S-201 STRUCTURAL ELEVATIONS
16 S-301 STRUCTURAL SECTIONS
17 S-302 STRUCTURAL SECTIONS
18 S-303 STRUCTURAL SECTIONS
19 S-501 TYPICAL STRUCTURAL DETAILS
20 S-502 TYPICAL STRUCTURAL DETAILS
ARCHITECTURAL
21 A-001 GENERAL NOTES & LEGENDS
22 A-002 GENERAL SYMBOLS
23 AD101 DEMOLITION ROOF & FLOOR PLANS
24 AD201 DEMOLITION EXTERIOR ELEVATIONS
25 A-100 PARTITION TYPES & DETAILS
26 A-101 ARCHITECTURAL FLOOR PLAN
27 A-102 REFLECTED CEILING PLAN
28 A-103 ROOF NEW WORK PLAN
29 A-201 EXTERIOR ELEVATIONS
30 A-202 INTERIOR ELEVATIONS
31 A-301 BUILDING CROSS SECTION
32 A-302 WALL SECTIONS
33 A-401 ENLARGED RESTROOM PLANS & DETAILS
34 A-501 WALL DETAILS
35 A-502 WALL DETAILS
36 A-503 PLAN DETAILS
37 A-504 CABINET DETAILS
38 A-601 FINISH SCHEDULE & DETAILS
39 A-602 DOOR SCHEDULE & DETAILS
40 A-603 DOOR DETAILS
41 A-604 WINDOW SCHEDULE & DETAILS
42 I-101 FLOORING PLAN
43 I-102 FURNITURE LAYOUT PLAN
44 LS101 LIFE SAFETY PLAN
FIRE PROTECTION
45 FD101 FIRST FLOOR DEMOLITION FIRE
PROTECTION PLAN
46 FA001 FIRE ALARM GENERAL NOTES, LEGENDS, &
DIAGRAMS
47 FA002 FIRE ALARM DIAGRAMS
48 FA101 FIRST FLOOR NEW WORK FIRE ALARM PLAN
49 FP001 FIRE PROTECTION GENERAL NOTES,
LEGENDS, & DIAGRAMS
50 FP101 FIRST FLOOR NEW WORK FIRE
PROTECTION PLAN
PLUMBING
51 P-001 GENERAL NOTES & LEGENDS
52 PD101 SANITARY DEMOLITION PLAN
53 PD102 DOMESTIC DEMOLITION PLAN
54 P-101 SANITARY NEW WORK PLAN
55 P-102 DOMESTIC NEW WORK PLAN
56 P-103 COMPRESSED AIR NEW WORK PLAN
57 P-104 CENTRAL VACUUM NEW WORK PLAN
58 P-501 PLUMBING DETAILS
59 P-502 PLUMBING DETAILS
60 P-601 PLUMBING SCHEDULES
61 P-701 PLUMBING ISOMETRICS
INDEX OF DRAWINGS
PLA
N
N O
R
TH
PLAN NORTH
SCALE: NOT TO SCALE
STATE MAP
SCALE: NOT TO SCALE
BASE MAP
SCALE: NOT TO SCALE
LOCATION MAP
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R
SEWER MANHOLE
TOP: 600.88'
6" CLAY INVERT: IN 596.98' (NORTHWEST)
6" CLAY INVERT: IN 596.03' (NORTH)
6" CLAY INVERT: IN 595.933' (SOUTHWEST)
6" CLAY INVERT: OUT 595.903' (SOUTHEAST)
BUILDING
BUILDING 1628
C A
R S
W E
L
A
V E
N U
E
G
S
T
R
E
E
T
LARGE ROCKS
(TYP. OF 11)
DUMPSTERS /
STORAGE CONTAINERS
CONCRETE PARKING AREA
AND SERVICE DRIVE
ASPHALT PARKING
AREA AND SERVICE
DRIVE
ASPHALT
PARKING
AREA
PIPE BOLLARDS
(TYP. OF 2)
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
M
B
Y
S I Z
E
F I
E
N
M
E
I S
S U
E
D
A T
E
C O
N T
R A
C
O
S O
L I C
I T
A T
I O
N
N
O
C K
D
B
Y x
D
C
B
A
F I
U M
B E
R
P L O
T
S
C A
L E
P L O
T
D
A T
E
SHEET OF
I r o n
H o r s e
D i v e
L a d s o n
S o u t h a r o l i n a
C E o j e c t
N o
N P r o j e c t
M a n a g e r
B r a d
M i n o r
L I F
E
S
U P
P O
I L D
I N
G
D D
A D
D I T
I O
N R
E N
O V
A T
I O
N
O
F
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
D
F A
D
N A
V A
L
A
A
T I O
N
J O
I N
T
R
E S
E R
S
E
F O
W
R
T H
T
X
09/16/2015
EXISTING CONDITIONS SURVEY
A1
SCALE: 1" = 20'
GRAPHIC SCALE
SCALE: 1" = 20'
20' 0 20' 40'
E T
M
J R
C
B W
M
VF101
M L J B
E X
I S
T I N
G
C
O N
D I T
I O
R
V E
Y
EXISTING LEGEND:
BUILDING OUTLINE
CONTOUR
SIDEWALK
EDGE OF PAVEMENT
CURB & GUTTER
SITE STRUCTURE
CONCRETE
SEWER LINE
OVERHEAD ELECTRICAL
ROCKS
COMMUNICATION EQUIPMENT
GAS EQUIPMENT
ELECTRICAL EQUIPMENT
MECHANICAL EQUIPMENT
DOWNSPOUT
SEWER MANHOLE
WATER METER
SURVEY BENCHMARK
N
O
R
T
H
UNDERGROUND COMMUNICATIONS
NATURAL GAS
TREE
DESCRIPTION
SITE CONTROL
NORTHING EASTING ELEVATION
6968135.325
6967988.477
2297856.501
2298048.063
602.42'
SET 1/2" IRON ROD WITH BLUE CAP
POINT NUMBER
5002 600.43'
SET 1/2" IRON ROD WITH BLUE CAP
WATER LINE
H O
W N
1. ALL SHADED ENTITIES WERE NOT SURVEYED. THESE ITEMS WERE
LOCATED BY BASE MAP OR GROUND PENETRATING RADAR.
CONTRACTOR TO FIELD VERIFY ALL LOCATIONS ON SITE.
2. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION, SIZES, AND
DEPTHS OF UNDERGROUND UTILITIES AT LEAST 48 HOURS PRIOR TO
CONSTRUCTION WHETHER SHOWN ON PLANS OR NOT, AND TO PROTECT
THE SAME DURING CONSTRUCTION.
GENERAL NOTE:
1. FIELD WORK PERFORMED ON: OCTOBER 21, 2014 & FEBRUARY 25, 2015 BY
MATKIN HOOVER SURVEYING, OF 8 SPENCER ROAD, STE 100, BOERNE, TEXAS.
2. ONLY APPARENT UTILITIES WERE LOCATED. NO ATTEMPT HAS BEEN MADE AS
PART OF THIS SURVEY TO SHOW THE EXISTENCE, SIZE, DEPTH, CONDITION, OR
LOCATION OF ANY UNDERGROUND UTILITY. FOR INFORMATION REGARDING
UNDERGROUND UTILITIES, PLEASE CONTACT THE APPROPRIATE AGENCY.
3. SITE CONTROL MUST BE VERIFIED ON THE JOB AND THE SURVEYOR MUST BE
NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH
CONSTRUCTION.
4. CONTRACTOR SHALL IMMEDIATELY NOTIFY SURVEYOR OF ANY QUESTIONS
THAT MAY ARISE CONCERNING THE INTENT, PLACEMENT, OR LIMITS OF POINTS
NECESSARY FOR CONSTRUCTION OF THIS PROJECT.
5. THE SURVEYOR ASSUMES NO LIABILITY FOR THE PLACEMENT OF THESE
POINTS ON THE GROUND BY OTHERS.
6. SITE CONTROL WAS ESTABLISHED USING THE TRIMBLE VRS NETWORK,
NAD(83), TEXAS STATE PLANE COORDINATE SYSTEM, NORTH CENTRAL ZONE,
4202, US SURVEY FOOT, GRID.
7. THIS SURVEY DOES NOT CONSTITUTE A BOUNDARY SURVEY AND SHALL NOT
BE RECORDED FOR ANY PURPOSE.
8. ALL POINTS MUST BE VERIFIED ON THE JOB AND THE SURVEYOR MUST BE
NOTIFIED OF ANY DISCREPANCIES.
SURVEY NOTES:
BUILDING
C A
R S
W E
E
N U
E
R
E
E
T
U N
K x
B
L
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I
M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
C K
D
B
Y x
D
C
B
A
F I
M
B E
R
P L O
T
S
C A
L E
P L O
T
D
A T
E
SHEET OF
o n
H o r i v e
L a d s o n
S o u r o l i n a
C E o j e c t
N o
N P r o j e c t
M a n a g e r
B r a d
M i n o r
L I F
E
S
U P
P O
I L D
I N
G
D D
A D
D I T
I O
N R
E N
O V
A T
I O
N
O
F
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
D
F A
D
N A
V A
L
A
A
T I O
N
J O
I N
T
R
E S
E R
S
E
F O
R
T H
T
X
09/16/2015
SITE DEMOLITION PLAN
A1
SCALE: 1" = 20'
GRAPHIC SCALE
SCALE: 1" = 20'
20' 0 20' 40'
E T
M
J R
C
B W
M
CD101
M L J B
S I T
E
D
E M
O L I T
I O
N
P
L A
N
DEMOLITION LEGEND
REMOVE SITE FEATURE
FULL DEPTH PAVEMENT SAWCUT
GENERAL NOTES:
N
O
R
T
H
O
W N
DEMOLITION KEYNOTES:
NO. DESCRIPTION
RELOCATE LARGE ROCKS AS SHOWN IN LANDSCAPING PLAN L-101 (TYP. OF 11).
TEMPORARILY RELOCATE DUMPSTERS/STORAGE CONTAINERS IN AREA OF DEMOLITION TO
INSTALLATION-ACCEPTABLE LOCATION (TYP.)
D1
D2
FULL-DEPTH SAWCUT & REMOVE CONCRETE/ASPHALTIC PAVEMENT COURSES AND BASE
MATERIAL (TYP.).
D3
SAWCUT/BREAK AND REMOVE CONCRETE CURBING AND BASE MATERIAL.
D4
REMOVE TREES (TYP. OF 2)
REMOVE NATURAL GAS MAIN (2 1/2"), BUILDING SERVICE LINE AND APPURTENANCES (TYP.)
REMOVE PIPE BOLLARD, FOUNDATION AND BASE MATERIAL (TYP. OF 3)
RELOCATE CONCRETE WHEEL STOPS TO INSTALLATION-ACCEPTABLE LOCATION OR REMOVE IF
NOT REUSABLE (TYP. OF 12)
SANDBLAST/REMOVE THERMOPLASTIC PAVEMENT MARKINGS.
SAWCUT/BREAK AND REMOVE CONCRETE WALK/PAD AND BASE MATERIAL. REMOVE OR
MAINTAIN MECHANICAL AND ELECTRICAL EQUIPMENT AS DIRECTED ON MECHANICAL AND
ELECTRICAL DRAWINGS.
REMOVE PLANTER ALONG BUILDING
FULL-DEPTH SAWCUT & REMOVE CONCRETE/ASPHALTIC PAVEMENT COURSES, CURB, BOLLARD(S)
AND BASE MATERIAL (TYP.) AS NECESSARY. PERFORM ELECTRICAL WORK AS DIRECTED IN
ELECTRICAL PLANS. PERFORM WORK OFF-PEAK HOURS, PROVIDE GRAVEL OR STEEL PLATES
TEMPORARILY TO MAINTAIN CONTINUED VEHICLE ACCESS DURING DEMOLITION AND CONSTRUCTION.
REPLACE PAVED SURFACE AND ALL SITE ITEMS IMPACTED TO MATCH EXISTING CONDITIONS.
D5
D6
D7
D8
D9
D10
D11
D12
EXISTING COMMUNICATIONS LINE TO
BE RELOCATED UNDER ANOTHER
CONTRACT (SEE ELECTRICAL PLANS)
EXISTING DOWNSPOUTS SHALL BE REMOVED IN AREAS OF SITE DEMOLITION AND BUILDING WORK.
NEW DOWNSPOUTS WITH SPLASH BLOCKS SHALL BE PROVIDED AS DIRECTED IN ARCHITECTURAL
PLANS.
D13
ELECTRICAL DEMOLITION, SEE ELECTRICAL PLANS.
D14
1. ALL AREAS SHOWN WITHIN THE LIMITS OF DEMOLITION AND CONSTRUCTION SHALL BE EXCAVATED
WITH CARE OR HAND-DUG AS NECESSARY TO ENSURE EXISTING FUNCTIONALITY OF ALL WORKS IS
MAINTAINED.
2. PROVIDE NEAT, CLEAN, STRAIGHT, SAW CUT EDGES.
3. ALL DISTURBED AREAS TO BE GRADED FOR POSITIVE DRAINAGE TO EXISTING STORM INLETS.
4. ALL AREAS WHERE EXISTING CONCRETE SLABS, SITE FEATURES, AND FOUNDATIONS ARE
REMOVED SHALL BE FILLED TO EXISTING GRADE AND SLOPED FOR POSITIVE DRAINAGE.
5. ALL DISTURBED AREAS TO BE GRASSED AFTER GRADING ACTIVITY HAS BEEN COMPLETED.
6. ALL DEMOLITION DEBRIS SHALL BE HAULED OFFSITE.
7. CONTRACTOR WILL BE RESPONSIBLE FOR ADDITIONAL REMOVAL AND REPLACEMENT OF
ASPHALT/CONCRETE PAVEMENT AND CONCRETE SIDEWALK AS NECESSARY TO CONSTRUCT THE
PROJECT. PAVEMENT AND SIDEWALK REMOVAL AND REPLACEMENT SHOWN IS THE MINIMUM
AMOUNT REQUIRED TO CONSTRUCT THE PROJECT.
8. THE LOCATION, SIZES, AND DEPTHS OF EXISTING UTILITIES, INCLUDING SERVICE LATERALS, AND
DRAINAGE STRUCTURES SHOWN ON THE PLANS ARE APPROXIMATE ONLY. THE CONTRACTOR
SHALL VERIFY THE EXACT LOCATION, SIZES, AND DEPTHS OF UNDERGROUND UTILITIES AT LEAST
48 HOURS PRIOR TO CONSTRUCTION WHETHER SHOWN ON PLANS OR NOT, AND TO PROTECT THE
SAME DURING CONSTRUCTION.
9. THE CONTRACTOR IS HEREBY CAUTIONED THAT ALL SITE FEATURES SHOWN HEREON ARE BASED
ON FIELD OBSERVATIONS BY THE SURVEYOR AND BY INFORMATION PROVIDED BY OTHERS. THE
INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE.
10. CONTRACTOR TO COORDINATE MARKING OF EXISTING SITE UTILITIES IN AREAS WHERE WORK IS
CONDUCTED.
11. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE WORKMANLIKE REPAIR OF ANY DAMAGE
DONE TO ANY NEW AND EXISTING SITE ITEMS IN THE EXECUTION OF HIS WORK UNDER THIS
SECTION.
12. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND BE
PREPARED TO ADEQUATELY CARE FOR AND SAFEGUARD HIMSELF AND THE GOVERNMENT FROM
DAMAGE.
13. CONTRACTOR SHALL FIELD ADJUST UTILITY MANHOLE RIMS, FIRE HYDRANTS, VALVES AND
APPURTENANCES TO MATCH FINISHED GRADE ELEVATIONS.
14. EXISTING DOWNSPOUTS SHALL BE REMOVED IN AREAS OF SITE DEMOLITION AND BUILDING WORK.
NEW DOWNSPOUTS WITH SPLASH BLOCKS SHALL BE PROVIDED AS DIRECTED IN ARCHITECTURAL
PLANS.
15. REFER TO ELECTRICAL SITE PLANS FOR COMMUNICATION AND ELECTRICAL INFRASTRUCTURE.
C A
R S
W E
E
N U
E
R
E
E
T
B
L
RELOCATE SEGMENT OF
NATURAL GAS MAIN (2 1/2")
(BY OTHERS, SEE NOTE 17)
MAINTAIN EXISTING ASPHALT PAVEMENT.
NEW BUILDING ADDITION,
REFER TO STRUCTURAL AND
ARCHITECTURAL PLANS
NEW BUILDING ENTRANCE
CANOPIES, REFER TO
STRUCTURAL, ARCH., AND
LANDSCAPE ARCH. PLANS
SLOPE GRASSED AREA AWAY FROM
NEW BUILDING AS REQUIRED
CONNECT TO EXISTING GAS
MAIN W/ 2 1/2" GATE VALVE W/
APPURTENANCES.
(BY OTHERS, SEE NOTE 17)
CONNECT TO EXISTING GAS
MAIN W/ 2 1/2" GATE VALVE W/
APPURTENANCES.
(BY OTHERS, SEE NOTE 17)
NEW BUILDING ENTRANCE
CANOPIES, REFER TO
STRUCTURAL, ARCH., AND
LANDSCAPE ARCH. PLANS
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
C K
D
B
Y x
D
C
B
A
F I L
E
N
U M
B E
R
P L
A
L E
P L
T
E
SHEET OF
I r o n
H o r s e
D r i v e
L a d s o n
S o u t h
C a r o l i n a
C E o j e c t
N o
N
P r o j e c t
M a n a g e r
B r a d
M i n o r
L I F
E
S
U P
P O
I L
D I N
G
D D
A D
D I T
I O
N R
E N
O V
A T
I O
N
O
F
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
D
F A
D
N A
V A
L
A
A
T I O
N
J O
I N
T
R
E S
E R
S
E
F O
R
T H
T
X
02/24/2016
CIVIL IMPROVEMENTS PLAN
A1
SCALE: 1" = 20'
GRAPHIC SCALE
SCALE: 1" = 20'
20' 0 20' 40'
E T
M
J R
C
B W
M
CI101
M L
J B
C I V
P R
O V
E M
E N
A
N
PROVIDE NEW BUILDING 1" NATURAL GAS
SERVICE WITH VALVES, METER, AND
APPURTENANCES (TYP.), COORDINATE
WITH BUILDING MECHANICAL PLANS
(BY OTHERS, SEE NOTE 17)
LEGEND:
BUILDING OUTLINE
GRADE CONTOUR
SIDEWALK
EDGE OF PAVEMENT
CURBING
SITE STRUCTURE
CONCRETE
SEWER LINE
GAS EQUIPMENT
MECHANICAL EQUIPMENT
DOWNSPOUT
SEWER MANHOLE
WATER METER / VALVE
NATURAL GAS
EXISTING: NEW:
WATER LINE
N
O
R
T
H
1. ALL AREAS SHOWN WITHIN THE LIMIT OF DEMOLITION AND CONSTRUCTION SHALL BE EXCAVATED WITH CARE OR HAND-DUG AS
NECESSARY TO ENSURE EXISTING FUNCTIONALITY OF ALL WORKS IS MAINTAINED.
2. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE WORKMANLIKE REPAIR OF ANY DAMAGE DONE TO ANY UTILITIES IN THE
EXECUTION OF HIS WORK UNDER THIS SECTION.
3. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND BE PREPARED TO ADEQUATELY CARE FOR
AND SAFEGUARD HIMSELF AND THE GOVERNMENT FROM DAMAGE.
4. NEW SITE FINISH GRADES SHALL MIMIC EXISTING CONDITIONS UNLESS OTHERWISE INDICATED, AND SHALL MEET EXISTING SITE
GRADES AT THE LIMIT OF SITE DISTURBANCE. GRADES SURROUNDING THE NEW AND EXISTING STRUCTURE SHALL PROVIDE
POSITIVE DRAINAGE AWAY FROM THE BUILDING. ALL CONCRETE PADS SHALL BE SLOPED AWAY FROM THE BUILDING
ACCORDINGLY.
5. ALL DISTURBED AREA THAT IS NOT PAVED SHALL BE HYDROSEEDED PER INSTALLATION SEEDING SPECIFICATION.
6. REFER TO ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, LANDSCAPE ARCHITECTURE, ELECTRICAL, AND MECHANICAL
DESIGN DRAWINGS FOR ADDITIONAL INFORMATION.
7. REFER TO DRAWING L-101 FOR RELOCATED PLACEMENT OF EXISTING LARGE ROCK IMPEDIMENTS.
8. SEDIMENT CONTROL MEASURES (TBD) SHALL BE IMPLEMENTED FOR THE DURATION OF DEMOLITION AND CONSTRUCTION (UNTIL
SITE STABILIZATION AND GROUND ESTABLISHMENT) IN ACCORDANCE WITH THE SEDIMENT CONTROL PLAN.
9. UTILITIES AND SIZES SHOWN ARE PER BASE UTILITY MAPS PROVIDED BY THE INSTALLATION. SURFACE UTILITY APPURTENANCES
AS SURVEYED WERE UTILIZED IN ILLUSTRATING THE UTILITIES AS SHOWN ON THIS PLAN. CONTRACTOR SHALL VERIFY
LOCATION, MATERIAL, TYPE, SIZE, & ELEVATION OF ALL EXISTING UTILITIES PRIOR TO COMMENCING WORK.
10. NEW DOWNSPOUTS SHALL BE PROVIDED AS DIRECTED IN ARCHITECTURAL PLANS, DISCHARGING TO EXTERIOR FINISH GRADE.
11. REFER TO ELECTRICAL SITE PLANS FOR COMMUNICATION AND ELECTRICAL INFRASTRUCTURE.
12. CONTRACTOR SHALL FIELD ADJUST UTILITY MANHOLE RIMS, FIRE HYDRANTS, VALVES AND APPURTENANCES TO MATCH
FINISHED GRADE ELEVATIONS.
13. CONTRACTOR WILL BE RESPONSIBLE FOR ADDITIONAL REMOVAL AND REPLACEMENT OF ASPHALT/CONCRETE PAVEMENT AND
CONCRETE SIDEWALK AS NECESSARY TO CONSTRUCT THE PROJECT. PAVEMENT AND SIDEWALK REMOVAL AND REPLACEMENT
SHOWN IS THE MINIMUM AMOUNT REQUIRED TO CONSTRUCT THE PROJECT.
14. THE LOCATION, SIZES, AND DEPTHS OF EXISTING UTILITIES, INCLUDING SERVICE LATERALS, AND DRAINAGE STRUCTURES
SHOWN ON THE PLANS ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION, SIZES, AND DEPTHS
OF UNDERGROUND UTILITIES AT LEAST 48 HOURS PRIOR TO CONSTRUCTION WHETHER SHOWN ON PLANS OR NOT, AND TO
PROTECT THE SAME DURING CONSTRUCTION.
15. THE CONTRACTOR IS HEREBY CAUTIONED THAT ALL SITE FEATURES SHOWN HEREON ARE BASED ON FIELD OBSERVATIONS BY
THE SURVEYOR AND BY INFORMATION PROVIDED BY OTHERS. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR
COMPLETE.
16. CONTRACTOR TO COORDINATE MARKING OF EXISTING SITE UTILITIES IN AREAS WHERE WORK IS CONDUCTED.
17. GAS PIPING OWNED/CONTROLLED BY PRIVATIZED UTILITY PROVIDER, CONTRACTOR TO CONTACT THE GOVERNMENT FOR THE
PRIVATIZED GAS PROVIDER. ALL GAS PIPING SHOWN INCLUDING THE GAS REGULATOR/METER SHALL BE COMPLETED BY GAS
PRIVATIZED UTILITY PROVIDER AND COORDINATED WITH THE GOVERNMENT. THE GAS LINE ROUTE SHALL BE COORDINATED
WITH THE PRIVATIZED UTILITY PROVIDER. ALL GAS PIPING SHALL BE COMPLETED IN ACCORDANCE WITH PRIVATIZED GAS
COMPANY SPECIFICATIONS. SIZES FOR THE GAS MAIN RELOCATION SHOWN ARE BASED UPON INSTALLATION UTILITY MAPS AND
SHALL BE VERIFIED BEFORE ORDERING MATERIALS.
18. CONTRACTOR TO VERIFY ALL EXISTING UTILITIES, LINE SIZES, AND NOTIFY THE ENGINEER OF RECORD OF ANY DISCREPANCIES
BEFORE ORDERING MATERIALS.
19. ALL WATER LINES TO BE RESTRAINED JOINT (RJ) PIPING WITH RJ FITTINGS AND THRUST BLOCKING.
GENERAL NOTES:
NEW MECHANICAL PAD / YARD AREA,
COORDINATE WITH MECHANICAL
& STRUCTURAL PLANS
MAINTAIN DOMESTIC WATER BUILDING
CONNECTION, REFER TO PLUMBING
PLANS FOR ADDITIONAL INFORMATION.
NEW 4' WIDE CONCRETE
WALK AND BASE MATERIAL (TYP.)
MODIFY EXISTING RAMP AREA AT
CURBLINE AS NECESSARY TO
MAINTAIN A.D.A ACCESSIBLE
HANDICAP RAMP. EXTEND
EXISTING CONCRETE CURB &
GUTTER, CONCRETE WALK,
BREAK CURB AND SLOPE
WALK AS NEEDED. PROVIDE
NEW DETECTABLE WARNING
PAVERS. REPLACE ANY
IMPACTED ADJACENT AREA
TO MATCH EXISTING
CONDITIONS.
NEW BITUMINOUS CONCRETE CURB, GUTTER
AND BASE MATERIAL TO MATCH EXISTING
POST INDICATOR VALVE
GATE VALVE
REMOTE FDC (SIAMESE CONNECTION)
NEW BOLLARD (4)
CHECK VALVE
BOLLARD
FIRE DEPARTMENT CONNECTION (FDC)
(SIAMESE CONNECTION)
6" RJ 45° BEND
6" RJ 90° BEND
NEW BITUMINOUS CONCRETE
CURB AND BASE MATERIAL (TYP.)
NEW CONCRETE
PAVEMENT AND BASE
MATERIAL TO MATCH EXISTING
NEW BOLLARD (IF NEEDED)
MAINTAIN SANITARY SEWER BUILDING
CONNECTION AND PROVIDE (2) NEW
CLEANOUT STRUCTURES. REFER TO
PLUMBING PLANS FOR ADDITIONAL
INFORMATION.
O
W N
EXISTING COMMUNICATIONS LINE TO BE
REMOVED UNDER ANOTHER CONTRACT
4" RJ DIP WATER LINE
ASPHALT PAVEMENT
NEW 4' WIDE CONCRETE
WALK AND BASE MATERIAL (TYP.)
NEW 4' WIDE CONCRETE
WALK AND BASE MATERIAL (TYP.)
NEW 4' WIDE CONCRETE
WALK AND BASE MATERIAL (TYP.)
eddie Polygon eddie Polygon
C A
R S
W E
E
N U
E
R
E
E
T
B
L
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I
M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
C K
D
B
Y x
D
C
B
A
F I
M
B E
R
P L O
T
S
C A
L E
P L O
T
D
A T
E
SHEET OF
o n
H o r i v e
L a d s o n
S o u r o l i n a
C E o j e c t
N o
N P r o j e c t
M a n a g e r
B r a d
M i n o r
L I F
E
S
U P
P O
I L D
I N
G
D D
A D
D I T
I O
N R
E N
O V
A T
I O
N
O
F
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
D
F A
D
N A
V A
L
A
A
T I O
N
J O
I N
T
R
E S
E R
S
E
F O
R
T H
T
X
09/16/2015
CIVIL SEDIMENT AND EROSION CONTROL PLAN
A1
SCALE: 1" = 20'
GRAPHIC SCALE
SCALE: 1" = 20'
20' 0 20' 40'
E T
M
J R
C
B W
M
CG101
M L J B
C I V
I L
S
E D
I M
E N
T
A
N D
E R
O S
I O
N
C
O N
T R
A
N
LEGEND:
N
O
R
T
H
CONTROL SEDIMENT RESULTING FROM DEMOLITION
AND CONSTRUCTION (SAWCUT, PLACEMENT OF CURB,
SIDEWALK) IN THIS AREA. SWEEP AND REMOVE ALL
DEBRIS AND SEDIMENT FROM WORK PERFORMED IN
THIS AREA DAILY, OR FREQUENTLY, AS NECESSARY.
SILT FENCE
SEDIMENT AND EROSION CONTROL PLAN
1. APPROXIMATELY 0.64 ACRES TO BE DISTURBED AS SHOWN BY THE CONSTRUCTION LIMITS.
2. INSTALL PERMANENT VEGETATIVE COVER AS SOON AS PRACTICAL IN THE DEVELOPMENT PROCESS.
3. SEDIMENT CAUSED BY CHANGED SOIL AND SURFACE CONDITIONS SHALL BE CONTAINED WITHIN THE
CONSTRUCTION SITE USING THE MEASURES SHOWN. MEASURES SHALL BE EMPTIED OR CLEANED
REGULARLY AND MAINTAINED IN PLACE AND IN GOOD CONDITION UNTIL GROUND COVER IS ESTABLISHED.
4. PLACE SILT FENCE BARRIERS AT LOCATIONS SHOWN ON PLAN. SILT BARRIERS SHALL BE MAINTAINED IN
PLACE AND IN GOOD CONDITION UNTIL GROUND COVER IS ESTABLISHED.
5. ALL DISTURBED AREAS NOT PAVED SHALL BE GRASSED. ALL GRASSING SHALL BE HYDROSEEDED PER THE
INSTALLATION STANDARD SEEDING SCHEDULE.
6. CONTRACTOR SHALL PROVIDE DUMPSTER OF SUFFICIENT SIZE TO CONTAIN THE SOLID WASTE GENERATED
BY THE PROJECT.
7. CONTRACTOR SHALL FREQUENTLY REMOVE GARBAGE TO MAINTAIN A CLEAN CONSTRUCTION SITE AND
MINIMIZE THE EXPOSURE OF WASTE TO STORM WATER.
8. PRIOR TO EXITING SITE, CONSTRUCTION VEHICLES AND TRUCKS SHALL WASH WHEELS IN AN AREA WITHIN
THE SILT FENCE LIMITS TO PREVENT SEDIMENT TRACKING UPON LEAVING AREA.
CONTROL SEDIMENT RESULTING FROM DEMOLITION
AND CONSTRUCTION (SAWCUT, PLACEMENT OF
ENTRANCE) IN THIS AREA. SWEEP AND REMOVE ALL
DEBRIS AND SEDIMENT FROM WORK PERFORMED IN
THIS AREA DAILY, OR FREQUENTLY, AS NECESSARY.
LIMITS OF CONSTRUCTION
O
W N
GENERAL NOTES:
1. ALL DISTURBED AREAS TO BE GRADED FOR POSITIVE DRAINAGE TO EXISTING STORM INLETS.
2. ALL AREAS WHERE EXISTING CONCRETE SLABS, SITE FEATURES, AND FOUNDATIONS ARE REMOVED SHALL BE
FILLED TO EXISTING GRADE AND SLOPED FOR POSITIVE DRAINAGE.
3. ALL DISTURBED AREAS TO BE GRASSED AFTER GRADING ACTIVITY HAS BEEN COMPLETED.
4. ALL DEMOLITION DEBRIS SHALL BE HAULED OFFSITE.
5. THE LOCATION, SIZES, AND DEPTHS OF EXISTING UTILITIES, INCLUDING SERVICE LATERALS, AND DRAINAGE
STRUCTURES SHOWN ON THE PLANS ARE APPROXIMATE ONLY. THE CONTRACTOR SHALL VERIFY THE EXACT
LOCATION, SIZES, AND DEPTHS OF UNDERGROUND UTILITIES AT LEAST 48 HOURS PRIOR TO CONSTRUCTION
WHETHER SHOWN ON PLANS OR NOT, AND TO PROTECT THE SAME DURING CONSTRUCTION.
6. THE CONTRACTOR IS HEREBY CAUTIONED THAT ALL SITE FEATURES SHOWN HEREON ARE BASED ON FIELD
OBSERVATIONS BY THE SURVEYOR AND BY INFORMATION PROVIDED BY OTHERS. THE INFORMATION IS NOT TO
BE RELIED ON AS BEING EXACT OR COMPLETE.
7. CONTRACTOR TO COORDINATE MARKING OF EXISTING SITE UTILITIES IN AREAS WHERE WORK IS CONDUCTED.
8. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE WORKMANLIKE REPAIR OF ANY DAMAGE DONE TO ANY
NEW AND EXISTING SITE ITEMS IN THE EXECUTION OF HIS WORK UNDER THIS SECTION.
9. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS AND BE PREPARED TO
ADEQUATELY CARE FOR AND SAFEGUARD HIMSELF AND THE GOVERNMENT FROM DAMAGE.
CONSTRUCTION SEQUENCE:
1. INSTALL SILT FENCE WHERE INDICATED ON THE PLANS. DISTURBANCE SHOULD BE
MINIMAL AS NECESSARY TO INSTALL SILT FENCE.
2. REMOVE AND/OR DEMOLISH EXISTING SITE FEATURES AS INDICATED ON THE
DEMOLITION PLAN.
3. INSTALLATION AND TRENCHING OF ALL WATER, ELECTRICAL AND GAS LINES MAY
BEGIN. SEE ELECTRICAL PLANS.
4. FILL AND COMPACT TRENCHES.
5. INITIATE TEMPORARY AND PERMANENT VEGETATIVE STABILIZATION MEASURES.
6. INSTALL STONE BASE COURSE AND ASPHALT AS INDICATED ON THE PLANS.
7. INSTALL CONCRETE SIDEWALK SPECIFIED AS INDICATED ON THE PLANS.
8. SEED ALL DISTURBED AREAS WITH PERMANENT APPROVED GRASS SEED ONCE ALL
WORK IS COMPLETE.
9. REMOVE ACCUMULATED SEDIMENT AND MAINTAIN SEDIMENT DEVICES UNTIL SITE HAS
BEEN STABILIZED.
10. REMOVE SEDIMENT DEVICES ONCE SITE HAS BEEN STABILIZED AND GIVEN APPROVAL
BY GOVERNMENT.
1. PROVIDE BUILDING I.D. ON REMOTE FIRE DEPT. CONNECTION.
2. NO TREES, BUSHES OR WALLS WITHIN 5' RADIUS OF FIRE DEPT. CONNECTION
3. IF FIRE SPRINKLER DESIGN INDICATES DEMAND OF 1000 GPM OR GREATER,
THE UNDERGROUND FIRE DEPT. CONNECTION LINE SHALL BE INCREASED TO 6"
DIAMETER WITH A THREE WAY 2 1/2" FIRE DEPT. HOSE CONNECTION.
4. 4' MIN. TO BACK OF CURB, OR 2' MIN TO BACK OF SIDEWALK, OR WHEN NO
CURB, 4' MAX. OUTSIDE THE CLEAR ZONE.
5. SEE BOLLARD DETAIL FOR BOLLARD PLACEMENT.
GENERAL NOTES:
4" - CLASS 350 D.I.P.
FOR CONTINUATION SEE
GROUND
CIVIL SITE PLAN.
LEVEL
M I N
I M
U M
JOINT RESTRAINT PER
MAG STD. DETAIL 303
M I N
I M
U M
4" WRAPPED STEEL PIPE
PER FIRE CODE, C.O.S.
SUPPLEMENT AND
A.W.W.A. "C" 150
2 1/2" X 2 1/2" X 4"
FIRE DEPARTMENT
CONNECTION NST TO FACE
STREET
3'
3/4" DRIP BALL DRIP
THRUST BLOCK (SEE
DETAIL THIS SHEET)
BACKFILL WITH 3/4" CRUSHED
ROCK MIN. OF 6 C.F.
SIDE VIEW
TOP VIEW
2 1/2" X 2 1/2" X 4"
FIRE DEPARTMENT
CONNECTION NST
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I
M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
C K
D
B
Y x
D
C
B
A
F I
M
B E
R
P L O
T
S
C A
L E
P L O
T
D
A T
E
SHEET OF
o n
H o r i v e
L a d s o n
S o u r o l i n a
C E o j e c t
N o
N P r o j e c t
M a n a g e r
B r a d
M i n o r
L I F
E
S
U P
P O
I L D
I N
G
D D
A D
D I T
I O
N R
E N
O V
A T
I O
N
O
F
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
D
F A
D
N A
V A
L
A
A
T I O
N
J O
I N
T
R
E S
E R
S
E
F O
R
T H
T
X
09/16/2015
E T
M
J R
C
B W
M
C-501
M L J B
C I V
T
A I L S
WATER LINE BEDDING DETAIL
SCALE: NOT TO SCALE
M I N
C
O V
E R
UNDISTURBED SOIL
CONCRETE SUPPORT
M I N
VALVE
CAST IRON VALVE BOX,
BITUMASTIC COATED,
MECHANICAL JOINT FITTING
TYLER 461S
PRECAST CONCRETE
COLLAR AROUND ALL
VALVE BOXES
VALVE & BOX DETAIL
S L O
P E
/2
S
L O
P E
/2
TAMPER SWITCH
GATE VALVE
SCALE: NOT TO SCALE
POST INDICATOR VALVE
INDICATOR POST SHALL
CONFORM TO
UNDERWRITERS
LABORATORIES
STANDARD UL-789
4' X 4
CONCRETE
COLLAR
CONDUIT TO FIRE
ALARM SYSTEM FOR
TAMPER SWITCH
CONNECTION (SEE
ELECTRICAL & FIRE
PROTECTION PLANS)
FINISHED GRADE
SCALE: NOT TO SCALE
4'
5'
CONTRACTION JOINTS
50' MAX. SPACING BETWEEN EXPANSION JOINTS
4. CONTRACTION JOINTS SHALL BE SPACED AT 5'-0"
ABUTS CONCRETE STRUCTURE.
3. EXPANSION MATERIAL 1/2" THICK SHALL BE REQUIRED WHERE SIDEWALK
1. SIDEWALKS SHALL BE 4" THICK (UNREINFORCED), 3500 PSI COMP. STRENGTH MIN.
2. CONTRACTION JOINTS SHALL BE 1" DEEP AND EDGED WITH 1/8" RADIUS.
1/4" EXP. JT.
5. SIDEWALKS TO LIGHT BROOM FINISH
6. SIDEWALK SUFACE AND ALL JOINTS AND EDGES TO BE TOOLED.
TYPICAL SIDEWALK DETAIL
SCALE: NOT TO SCALE
16"
6"
FINISH GRADE
EXISTING PAVEMENT
CONCRETE CURB
PROVIDE 18"x18"x12"
THICK CONCRETE PAD
FINISHED GRADE
ADJUSTABLE VALVE
BOX SLIP
PLUG VALVE
PE COATED STEEL PIPE
(TYP.)
TRANSITION FROM PE
PIPE TO PE COATED
STEEL PIPE (TYP.)
36" 36"
BRICK
RAISED LETTERS ON
COVER THAT READ
"GAS"
TYPICAL GAS VALVE & BOX DETAIL
SCALE: NOT TO SCALE
TYPICAL CURB DETAIL
SCALE: NOT TO SCALE
D1
D2
B1
A2
C4
C3
6"
FIRE DEPARTMENT REMOTE SIAMESE CONNECTION
A4
SCALE: NOT TO SCALE
A1
SCALE: NOT TO SCALE
CLEANOUT DETAIL
NOTES:
O
W N
DITCH LINE
6"
UTILITY
PAVEMENT REPLACEMENT DETAIL
SAW CUT
SAW CUT
MATCH EXISTING OR MINIMUM 2.0"
ASPHALT/CONCRETE PAVEMENT
COURSE
SELECTIVE BACKFILL
TAMPED IN 6" LAYERS
TO 95% COMPACTION
PER ASTM D-1557
MATCH EXISTING
BASE
1. MATCH EXISTING
PAVEMENT SECTION OR
INSTALL THE MINIMUM
SHOWN, WHICHEVER IS
GREATER.
NOTES:
C2
MATCH EXISTING
OR MINIMUM 8"
STONE BASE
2" 2"
SCALE: NOT TO SCALE
CONCRETE ENCASEMENT
4" MIN. COVER
MAIN WYE
STANDARD 1/8 BEND
C.I. PIPE RISER
CLEANOUT PLUG
CLEANOUT BOX
CONCRETE
ROUND CONCRETE
COLLAR
#3 BARS ALL AROUND
(W/6" OVERLAP)
SHORT LENGTH OF CAST
IRON PIPE FURNISHED
W/CLEANOUT BOX
CLEANOUT
Q
U I R
E D
4" TYP.
6" MAIN WYE
FOR ADDITIONAL
SERVICE (IF
APPLICABLE)
IN PAVEMENT OR CONCRETE,
CONTRACTOR SHALL USE CAST
IRON BOX W/ COVER AND
THREADED CLEANOUT PLUG. KEEP
1" MIN CLEARENCE OF PLUG
PLAN
ELEVATION
MAIN WYE
ENTIRE BARREL OF PIPE TO
REST ON BOTTOM OF TRENCH
FINISHED GRADE
UNDISTURBED SOIL
WATER LINE
CROSS SECTION
PIPE ZONE
Bc c
M
I N
NOTE: INSTALL BEDDING
TO ALL PIPES 4"-12"Ø. NO
BEDDING IS REQ'D FOR
PIPES < 4"Ø.
Bc + 12"
TRACER WIRE
COMPACTED
CLASS 2 BACKFILL
TRACER WIRE
WARNING
MAGNETICALLY
DETECTABLE TAPE
PER SPECS.
12" MIN. OR PIPE
DIAMETER
WHICHEVER IS
GREATER
COMPACTED TO A
DENSITY OF 98% AT
OPTIMUM MOISTURE
(ASTM D-1557)
MAGNETICALLY
DETECTABLE TAPE 6" -
12" BELOW GRADE USE
FOR ALL TYPES OF PIPE
COMPACTED
CLASS 2 BACKFILL
COMPACTED TO A CLASS 2 BACKFILL.
COMPACTED TO A DENSITY OF 98% AT
OPTIMUM MOISTURE (ASTM D-1557)
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N
B
Y
D E
S I G
N
B
Y
S B
S I Z
E
F I L
E
N
A M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
C K
D
B
Y x
D
C
B
A
F I L
E
N
U M
B E
R
P L
A
L E
P L
T
E
SHEET OF
I r o n
H o r s e
D r i v e
L a d s o n
S o u t h
C a r o l i n a
C E o j e c t
N o
N
P r o j e c t
M a n a g e r
B r a d
M i n o r
L I F
E
S
U P
P O
I L
D I N
G
D D
A D
D I T
I O
N R
E N
O V
A T
I O
N
O
F
M A
R K
D E
S C
R I P
T I O
N D
A T
E A
P P
R
D
F A
D
N A
V A
L
A
A
T I O
N
J O
I N
T
R
E S
E R
S
E
F O
R
T H
T
X
02/24/2016
TEMPORARY INLET SEDIMENT FILTER
TO BE INSTALLED ON ALL PAVED
CATCH BASINS OR STORM INLETS.
INLET FILTER TO BE SIMILAR TO
"STREAMGUARD" AS MANUFACTURED
BY STORMWATER SERVICES
CORPORATION (206-767-0441) OR
"SILTSACK" AS MANUFACTURED BY
ATLANTIC CONSTRUCTION FABRICS,
INC. (800-448-3636). CLEAN FILTER AS
NEEDED.
SILT SACK DETAIL
SCALE: NOT TO SCALE
A4
NOTE:
FLAT BOTTOM TRENCH DETAIL
M
A
X
I
M
A
C
I
FILTER FABRIC
BACKFILL TRENCH WITH
COMPACTED EARTH
COMPACTED
EARTH
COMPACTED
EARTH
FILTER FABRIC
6"
6"
24"
(MINIMUM)
6"
R
U
N
O
F
F
RUNOFF
RUNOFF
18-24"
BURY FABRIC
USE EITHER FLAT-BOTTOM
OR V-BOTTOM TRENCH
SEE DETAILS
FILTER
FABRIC
BURY FILTER FABRIC
AT LEAST 12"
1.25 LB./LINEAR FT. STEEL POSTS
HEAVY DUTY PLASTIC TIE
FOR STEEL POSTS
(RESTRICT TO TOP
8-INCHES OF FABRIC)
SILT FENCE - GENERAL NOTES
1. DO NOT PLACE SILT FENCE ACROSS CHANNELS OR IN
OTHER AREAS SUBJECT TO CONCENTRATED FLOWS.
SILT FENCE SHOULD NOT BE USED AS A VELOCITY
CONTROL BMP. CONCENTRATED FLOWS ARE ANY
FLOWS GREATER THAN 0.5 CFS.
2. MAXIMUM SHEET OR OVERLAND FLOW PATH LENGTH TO
THE SILT FENCE SHALL BE 100-FEET.
3. MAXIMUM SLOPE STEEPNESS (NORMAL
[PERPENDICULAR] TO THE FENCE LINE) SHALL BE 2:1.
4. SILT FENCE JOINTS, WHEN NECESSARY, SHALL BE
COMPLETED BY ONE OF THE FOLLOWING OPTIONS:
WRAP EACH FABRIC TOGETHER AT A SUPPORT POST
WITH BOTH ENDS FASTENED TO THE POST, WITH A
1-FOOT MINIMUM OVERLAP:
-- OVERLAP SILT FENCE BY INSTALLING 3-FEET PASSED
THE SUPPORT POST TO WHICH THE NEW SILT FENCE
ROLL IS ATTACHED. ATTACH OLD ROLL TO NEW
ROLL WITH HEAVY-DUTY PLASTIC TIES; OR,
-- OVERLAP ENTIRE WIDTH OF EACH SILT FENCE ROLL
FROM ONE SUPPORT POST TO THE NEXT SUPPORT
POST.
5. ATTACH FILTER FABRIC TO THE STEEL POSTS USING
HEAVY-DUTY PLASTIC TIES THAT ARE EVENLY SPACED
WITHIN THE TOP 8-INCHES OF THE FABRIC.
4. INSTALL THE SILT FENCE PERPENDICULAR TO THE
DIRECTION OF THE STORMWATER FLOW AND PLACE THE
SILT FENCE THE PROPER DISTANCE FROM THE TOE OF
STEEP SLOPES TO PROVIDE SEDIMENT STORAGE AND
ACCESS FOR MAINTENANCE AND CLEANOUT.
5. INSTALL SILT FENCE CHECKS (TIE-BACKS) EVERY 50-100
FEET, DEPENDENT ON SLOPE, ALONG SILT FENCE THAT
IS INSTALLED WITH SLOPE AND WHERE CONCENTRATED
FLOWS ARE EXPECTED OR ARE DOCUMENTED ALONG
THE PROPOSED/INSTALLED SILT FENCE.
HEAVY DUTY
PLASTIC TIES
FILTER FABRIC
HEAVY DUTY
PLASTIC TIES
SILT FENCE - POST REQUIREMENTS
1. SILT FENCE POSTS MUST BE 48-INCH LONG STEEL POSTS THAT MEET, AT A MINIMUM,
THE FOLLOWING PHYSICAL CHARACTERISTICS.
-- COMPOSED OF A HIGH STRENGTH STEEL WITH A MINIMUM YIELD STRENGTH OF
50,000 PSI.
-- INCLUDE A STANDARD "T" SECTION WITH A NOMINAL FACE WIDTH OF 1.38-INCHES
AND A NOMINAL "T" LENGTH OF 1.48-INCHES.
-- WEIGH 1.25 POUNDS PER FOOT (± 8%)
2. POSTS SHALL BE EQUIPPED WITH PROJECTIONS TO AID IN FASTENING OF FILTER
FABRIC.
3. STEEL POSTS MAY NEED TO HAVE A METAL SOIL STABILIZATION PLATE WELDED
NEAR THE BOTTOM WHEN INSTALLED ALONG STEEP SLOPES OR INSTALLED IN LOOSE
SOILS. THE PLATE SHOULD HAVE A MINIMUM CROSS SECTION OF 17-SQUARE INCHES
AND BE COMPOSED OF 15 GAUGE STEEL, AT A MINIMUM. THE METAL SOIL
STABILIZATION PLATE SHOULD BE COMPLETELY BURIED.
4. INSTALL POSTS TO A MINIMUM OF 24-INCHES. A MINIMUM HEIGHT OF 1- TO 2- INCHES
ABOVE THE FABRIC SHALL BE MAINTAINED, AND A MAXIMUM HEIGHT OF 3 FEET SHALL
BE MAINTAINED ABOVE THE GROUND.
5. POST SPACING SHALL BE AT A MAXIMUM OF 6-FEET ON CENTER.
SILT FENCE - FABRIC REQUIREMENTS
1. SILT FENCE MUST BE COMPOSED OF WOVEN GEOTEXTILE FILTER FABRIC THAT
CONSISTS OF THE FOLLOWING REQUIREMENTS:
-- COMPOSED OF FIBERS CONSISTING OF LONG CHAIN SYNTHETIC POLYMERS OF AT
LEAST 85% BY WEIGHT OF POLYOLEFINS, POLYESTERS, OR POLYAMIDES THAT
ARE FORMED INTO A NETWORK SUCH THAT THE FILAMENTS OR YARNS RETAIN
DIMENSIONAL STABILITY RELATIVE TO EACH OTHER;
-- FREE OF ANY TREATMENT OR COATING WHICH MIGHT ADVERSELY ALTER ITS
PHYSICAL PROPERTIES AFTER INSTALLATION;
-- FREE OF ANY DEFECTS OR FLAWS THAT SIGNIFICANTLY AFFECT ITS PHYSICAL
AND/OR FILTERING PROPERTIES; AND,
-- HAVE A MINIMUM WIDTH OF 36-INCHES.
2. 12-INCHES OF THE FABRIC SHOULD BE PLACED WITHIN EXCAVATED TRENCH AND
TOED IN WHEN THE TRENCH IS BACKFILLED.
3. FILTER FABRIC SHALL BE PURCHASED IN CONTINUOUS ROLLS AND CUT TO THE
LENGTH OF THE BARRIER TO AVOID JOINTS.
4. FILTER FABRIC SHALL BE INSTALLED AT A MINIMUM OF 24-INCHES ABOVE THE
GROUND.
1. THE KEY TO FUNCTIONAL SILT FENCE IS WEEKLY
INSPECTIONS, ROUTINE MAINTENANCE, AND
REGULAR SEDIMENT REMOVAL.
2. REGULAR INSPECTIONS OF SILT FENCE SHALL BE
CONDUCTED ONCE EVERY CALENDAR WEEK AND, AS
RECOMMENDED, WITHIN 24-HOURS AFTER EACH
RAINFALL EVEN THAT PRODUCES 1/2-INCH OR MORE
OF PRECIPITATION.
3. ATTENTION TO SEDIMENT ACCUMULATIONS ALONG
THE SILT FENCE IS EXTREMELY IMPORTANT.
ACCUMULATED SEDIMENT SHOULD BE CONTINUALLY
MONITORED AND REMOVED WHEN NECESSARY.
4. REMOVE ACCUMULATED SEDIMENT WHEN IT
REACHES 1/3 THE HEIGHT OF THE SILT FENCE.
5. REMOVED SEDIMENT SHALL BE PLACED IN
STOCKPILE STORAGE AREAS OR SPREAD THINLY
ACROSS DISTURBED AREA. STABILIZE THE REMOVED
SEDIMENT AFTER IT IS RELOCATED.
6. CHECK FOR AREAS WHERE STORMWATER RUNOFF
HAS ERODED A CHANNEL BENEATH THE SILT FENCE,
OR WHERE THE FENCE HAS SAGGED OR COLLAPSED
DUE TO RUNOFF OVERTOPPING THE SILT FENCE.
INSTALL CHECKS/TIE-BACKS AND/OR REINSTALL SILT
FENCE, AS NECESSARY.
7. CHECK FOR TEARS WITHIN THE SILT FENCE, AREAS
WHERE SILT FENCE HAS BEGUN TO DECOMPOSE,
AND FOR ANY OTHER CIRCUMSTANCE THAT MAY
RENDER THE SILT FENCE INEFFECTIVE. REMOVED
DAMAGED SILT FENCE AND REINSTALL NEW SILT
FENCE
IMMEDIATELY.
8. SILT FENCE SHOULD BE REMOVED WITHIN 30 DAYS
AFTER FINAL STABILIZATION IS ACHIEVED AND ONCE
IT IS REMOVED, THE RESULTING DISTURBED AREA
SHALL BE PERMANENTLY
STABILIZED.
SILT FENCE - INSPECTION & MAINTENANCE
V-SHAPED TRENCH DETAIL
SILT FENCING
NOT TO SCALE
18-24"
24"
(MINIMUM)
B1
C-502
C I V
T
A I L
S
E T
M
J R
C
B W
M
M L
J B
N O
N E
CROWN TOP OF
CONCRETE TO DRAIN
AWAY FROM BOLLARD
2'-0"
M
I N
3'-0"
6"Ø STEEL BOLLARD
WITH CAP YELLOW
PAINTED FINISH
8"
8"
6"
1. PROVIDE 6" Ø CONCRETE FILLED BOLLARD W/ CAP-MILL FINISH
2. STEEL PIPE SHOULD BE GALVANIZED (2.0 OZ ZINC/SQ FT).
3. PROVIDE MIN WALL THICKNESS OF 0.322"
4. CONTRACTOR SHALL RE-USE EXISTING OR PROVIDE NEW BOLLARDS.
NOTES:
SCALE: NOT TO SCALE
A1
BOLLARD DETAIL
1"
3'-0"
3'-0"
PLAN
SIAMESE FIRE
DEPARTMENT
CONNECTIONS
CONCRETE
THRUST BLOCK DETAIL (SEE SCHEDULE BELOW)
6"
MIN.
8 MIL POLYETHYLENE
18" MIN FOR PIPE < 18"
"D" MIN FOR PIPE > 18"
SECTION X-X
BENDS & TEES
SHEET
PLAN & ELEVATION
PLUGS
8 MIL POLYETHYLENE
UNDISTURBED
18" MIN FOR PIPE < 18"
"D" MIN FOR PIPE > 18"
PIPE DIA "D"
B
B
D
SHEET
B
S Q
D
A x
B
EARTH
UNDISTURBED
X
PLAN
BENDS
EARTH
A
A
PLAN
TEES
X
X
X
6" MIN.
DESIGN PIPE PRESSURE = 150 PSI
ALLOWABLE SOIL BEARING PRESSURE = 2000 PSF
NOTE:
1. DIMENSIONS A & B SHALL BE DETERMINED IN THE FIELD AS
REQUIRED TO PROVIDE THE GIVEN BEARING AREA AND TO MEET
FIELD CONDITIONS.
B4
SCALE: NOT TO SCALE
3.00 0.83
1.62 2.122.12
MIN. THRUST BLOCK BEARING AREAS (S.F.)
SIZE
4 1.33
AxB
0.40
AxB
0.72
AxB
90°
BEND
22 1/2°
45°
BEND
BEND
AxB
0.94
AxB
0.94
PLUGS
TEES
3.78 3.78 2.88
1.50 5.33
8.50 8.50 6.50
3.33 12.00 eddie Polygon eddie Callout Added this detail
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
THE STRUCTURE IS DESIGNED AS A STABLE UNIT AFTER ALL COMPONENT
PARTS ARE IN PLACE. THEREFORE, THE CONTRACTOR/ERECTOR SHALL
PROVIDE ALL NECESSARY SHORING AND BRACING AS REQUIRED TO ENSURE
STABILITY DURING ERECTION.
WHEN A DETAIL IS SHOWN ON THE STRUCTURAL DRAWINGS FOR ONE
CONDITION, IT SHALL APPLY TO ALL SIMILAR OR LIKE CONDITIONS, UNLESS
NOTED OR SHOWN OTHERWISE ON THE DRAWINGS.
DESIGN CRITERIA:
A: FLOOR LIVE LOAD:
OFFICE
CORRIDOR AND LOBBY
MECHANICAL ROOM
B: ROOF LIVE LOAD:
C: GROUND SNOW LOAD, Pg:
D: WIND LOADS
a. ULTIMATE WIND SPEED, Vult:
b. NOMINAL WIND SPEED, Vasd:
c. RISK CATEGORY:
d. WIND EXPOSURE:
e. INTERNAL PRESSURE COEFFICIENT:
f. PRESSURE COEFFICIENT ZONE WIDTH, a:
g. COMPONENT AND CLADDING WIND PRESSURE:
EFFECTIVE AREAS: 20 SF (ENCLOSED); 9 TO 36 SF (OPEN)
CANOPY:
ROOF:
WALL:
E: SEISMIC LOADS
a. RISK CATEGORY:
b. SEISMIC IMPORTANCE FACTOR, Ie:
c. MAPPED SPECTRAL RESPONSE,
d. SITE CLASS:
e. DESIGN SPECTRAL RESPONSE,
f. SEISMIC DESIGN CATEGORY:
g. BASIC SEISMIC FORCE RESISTING SYSTEM:
INTERMEDIATE REINFORCED
MASONRY SHEAR WALLS
h. RESPONSE MODIFICATION COEFFICIENT,
i. SEISMIC RESPONSE COEFFICIENT, Cs:
j. DESIGN BASE SHEAR:
k. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE
THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH IBC 2012, ASCE 7-10, UFC
3-301-01, AND UFC 4-010-01.
STEEL DECK SHALL BE MINIMUM 3 SPAN CONDITION WITH THE FOLLOWING
MINIMUM PROPERTIES.
ROOF:
TYPE 1.5B22
In = 0.183 in^4/ft. Ip = 0.155 in^4/ft.
Sn = 0.192 in^3/ft. Sp = 0.186 in^3/ft. Fy = 40 ksi
CONTRACTOR SHALL FULLY COORDINATE ALL ARCHITECTURAL AND
STRUCTURAL DRAWINGS (INCLUDING DIMENSIONS AND ELEVATIONS) AND
SHALL FULLY RESOLVE ANY CONFLICTS PRIOR TO COMMENCING WORK.
FABRICATION DRAWINGS SHALL NOT BE REPRODUCTION OF STRUCTURAL
CONTRACT DRAWINGS.
MISCELLANEOUS STRUCTURAL ITEMS, CONDITIONS OR PIECES OF STEEL MAY
BE SHOWN ON ARCHITECTURAL DRAWINGS.
CONTRACTOR SHALL CONSULT ROICC FOR DIRECTION SHOULD UNCHARTED
OR INCORRECTLY CHARTED PIPING OR OTHER UTILITIES BE ENCOUNTERED
DURING SITE CLEARING, GRADING AND EXCAVATION.
50 PSF
100 PSF
125 PSF
20 PSF
5 PSF
115 MPH
89 MPH
II
C ±0.18
6.5 FT (ENCLOSED)
3.0 FT (OPEN)
ZONE 1: 27 PSF -31 PSF
ZONE 2: 41 PSF -47 PSF
ZONE 3: 41 PSF -47 PSF
ZONE 1: 17 PSF -27 PSF
ZONE 2: 17 PSF -45 PSF
ZONE 3: 17 PSF -67 PSF
ZONE 4: 30 PSF -32 PSF
ZONE 5: 30 PSF -39 PSF
II
1.00 Ss = 0.09 S1 = 0.05 C Sds = 0.072 Sd1 = 0.057 A
R = 3.5 0.018
8,000 LBS
FOUNDATION NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
THE GEOTECHNICAL REPORT IS A SECTION OF THE CONSTRUCTION
DOCUMENTS AND AS SUCH, ALL SOILS AND FOUNDATION WORK SHALL BE DONE
IN ACCORDANCE WITH TERRACON'S GEOTECHNICAL ENGINEERING REPORT FOR
PROPOSED BUILDING ADDITION-NASJRB FORT WORTH, TEXAS, PROJECT
NUMBER 95145107, DATED NOV. 20, 2014.
STRUCTURAL FOUNDATION DESIGN IS BASED UPON AN ALLOWABLE SOIL
BEARING CAPACITY OF 2,000 PSF PER THE GEOTECHNICAL REPORT.
LATERAL SOIL PRESSURE BASED ON SOIL DENSITY OF 120 PCF WITH AN ANGLE
OF INTERNAL REPOSE OF 30 DEGREES.
ALL FOUNDATIONS ARE TO BEAR ON UNDISTURBED IN-SITU SOIL OR ON TESTED
STRUCTURAL BACKFILL. FILL SHALL BE PLACED IN UNIFORM LIFTS OF NO MORE
THAN 8 INCHES THICK AND COMPACTED TO 95% STANDARD PROCTOR VALUE
FOR BACKFILL IN ACCORDANCE WITH ASTM D-698 (THIS INCLUDES THE LAYER OF
CLEAN WASHED SAND OR STONE FOR SLABS ON GRADE). THE MAXIMUM
PARTICLE SIZE FOR FILL PLACEMENT SHALL NOT EXCEED 2/3 OF THE LIFT
THICKNESS.
MAINTAIN POSITIVE SURFACE DRAINAGE TO PREVENT THE ACCUMULATION OF
WATER IN EXCAVATED AREAS.
MATERIAL TO BE USED AS FILL SHALL BE TESTED BY AN APPROVED TESTING
LABORATORY TO DETERMINE SUITABILITY PRIOR TO BEING PLACED.
REMOVE ALL ORGANIC AND DELETERIOUS MATERIAL.
SURFACE AREAS AT GRADE AND AREAS TO RECEIVE FILL SOILS SHALL BE
DETERMINED WITHIN ±2 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE
CONTENT DETERMINED FROM THE STANDARD PROCTOR TEST.
IMMEDIATELY PRIOR TO CONSTRUCTION, SUB GRADE SOILS SHALL BE PROOF
ROLLED WITH A FULLY LOADED TANDEM-AXLE DUMP TRUCK OR SIMILAR
EQUIPMENT TO DETECT ANY UNSTABLE AREAS. THE PROOF ROLLING
EQUIPMENT SHALL MAKE A MINIMUM OF FOUR PASSES OVER EACH SECTION,
WITH THE LAST TWO PASSES PERPENDICULAR TO THE FIRST TWO. ANY AREAS
WHICH PUMP OR RUT SHALL BE UNDERCUT OR SCARIFIED AND DENSIFIED IN
PLACE AND PROOF ROLLED AGAIN CONTRACTOR SHALL NOTIFY ROICC PRIOR TO
COMMENCEMENT OF PROOF ROLLING OPERATIONS.
FILL PLACEMENT SHALL NOT BEGIN UNTIL PROOF ROLLING OPERATIONS ARE
SUCCESSFUL.
CONCRETE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI
318-11; BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE.
CONCRETE COMPRESSIVE STRENGTH SHALL BE 3,000 PSI MINIMUM AT 28 DAYS.
REINFORCING STEEL SHALL BE ASTM A615, GRADE 60.
WELDED WIRE FABRIC SHALL BE ASTM A1064. WELDED WIRE FABRIC WILL BE
PLACED AT MID DEPTH OF SLAB, UNLESS OTHERWISE NOTED.
PROPORTION AND DESIGN CONCRETE MIXES TO RESULT IN CONCRETE SLUMP
AT POINT OF PLACEMENT NOT LESS THAN 3" AND NOT MORE THAN 5".
ADDITION OF WATER TO READY-MIX IN THE FIELD SHALL NOT BE ALLOWED.
DEPOSIT CONCRETE IN A CONTINUOUS OPERATION UNTIL THE PLACING OF
CONCRETE IS COMPLETE. IF POUR IS TO BE DISCONTINUOUS, CONTRACTOR
SHALL USE CONSTRUCTION JOINTS.
CONCRETE MUST BE CURED FOR A MINIMUM 21 DAYS PRIOR TO ANY ADHESIVE
ANCHOR INSTALLATION.
SEE SECTION 7.7 OF ACI 318 FOR MINIMUM REINFORCED PROTECTION
REQUIREMENTS.
TYPICAL REINFORCEMENT SPLICES SHALL BE AS FOLLOWS:
10.1 #4 BARS - 22" LAP
10.2 #5 BARS - 28" LAP
10.3 #6 BARS - 33" LAP
10.4 #7 BARS - 48" LAP
10.5 #8 BARS - 55" LAP
SEE SPECIFICATION SECTION 03 30 00 FOR ADDITIONAL INFORMATION.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT (ACI 318-11, PARA 7.7):
1.
2.
3.
4.
CONCRETE CAST AGAINST AND PERMANENTLY
EXPOSED TO EARTH
CONCRETE EXPOSED TO EARTH OR WEATHER
#6 THROUGH #18
#3 THROUGH #5
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH
SLAB, WALLS, JOISTS
#3 THROUGH #11
#14 THROUGH #18
BEAMS, COLUMNS
SHELLS, FOLDED PLATE MEMBERS
#6 THROUGH #18
#3 THROUGH #5
CONCRETE EXPOSED TO MARINE/CORROSIVE ENVIRONMENTS (R.7.7.5)
WALLS & SLABS
OTHER MEMBERS
3"
2" 1 1/2"
3/4" 1 1/2"
1 1/2"
3/4" 1/2"
2" 2 1/2"
CONCRETE NOTES:
a a a a h
WALL WIND ZONES GABLE ROOF WIND ZONES (7° < Θ < 45°)
3 3
3 3
2 2
2 2
2 211 a a a aaa
CANOPY PITCHED FREE ROOF WIND ZONES (Θ ≥ 10°)
1 1 a a
L a a
No. 29581
S
OU
TH
CAROL IN
A
B
R A D L E Y W. M I N O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G
I N E E R
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N A
V A
L A
IR
S
T A
T
IO
N
C K
D B
Y x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
I T E
C T
U R
E C
E M
S P ro je c t N o
N
P ro je c t M a n a g e r:
B ra d M in o r
N O
N E
09/16/2015
/1
/2
:3 :4
P
M
O F
L
IF
E
S U
P P
O R
T B
U
IL
D
IN
G
D D
P M
/1 /2
D
F A
-1
-D
-0
B W
M
B D
M
B W
M
S-001
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
X B
W M
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
A D
D
IT
IO
N
/R E
N O
V A
T
IO
N
SCALE: NOT TO SCALEA2
WIND DIAGRAMS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
COLD-FORMED METAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
COLD FORMED STEEL DESIGN SHALL BE IN ACCORDANCE WITH THE AISI SPECIFICATION
FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS, 2001 EDITION.
COLD FORMED STEEL SHALL BE DESIGNED FOR WIND LOADING IN GENERAL NOTES.
DESIGN, DETAIL AND ERECT COLD-FORMED METAL FRAMING IN ACCORDANCE WITH ASTM
C955.
COLD-FORMED METAL FRAMING SIZES INDICATED ARE BASED ON A MINIMUM YIELD STRESS
OF 33 KSI.
ALL LOAD BEARING AND SHEAR WALLS SHALL HAVE LATERAL BRIDGING AT MID-HEIGHT OF
STUDS UNLESS NOTED OTHERWISE.
COLD-FORMED METAL FRAMING SHALL BE GALVANIZED IN ACCORDANCE WITH A653, G60.
GALVANIZING DAMAGED BY INSTALLATION OPERATIONS OR WELDING SHALL BE REPAIRED
USING GALVANIZING REPAIR PAINT CONFORMING TO SSPC-PAINT 20 OR DOD-P-21035.
COLD-FORMED METAL FRAMING GAUGES AND SIZES ARE BASED UPON THE STEEL STUD
MANUFACTURERS ASSOCIATION (SSMA).
METAL STUDS FOR BEARING WALLS TO BE 6", GAUGE AS INDICATED.
SEE SHEET S-502 FOR X-BRACED SHEAR WALL DETAIL THAT INCLUDES STRAPS, DOUBLE
STUDS, HOLD-DOWNS, AND ANCHORAGE INFORMATION.
SEE SHEET S-502 FOR TYPICAL COLD-FORMED METAL DETAILS.
METAL TRUSS NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
METAL TRUSSES SHALL BE DESIGNED, FABRICATED AND INSTALLED AS INDICATED ON
THE DRAWINGS AND IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE,
NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS 2007 AND AMERICAN IRON AND STEEL INSTITUTE STANDARD FOR
COLD-FORMED STEEL FRAMING - TRUSS DESIGN 2007.
SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED BY A REGISTERED
ENGINEER.
PROVIDE HORIZONTAL BRIDGING AS SHOWN ON THE DRAWINGS AND/OR AS
RECOMMENDED BY THE TRUSS MANUFACTURER, WHICHEVER IS GREATER.
THE TRUSS FRAMING SHOWN IS FOR INTENT OF DESIGN PURPOSES ONLY. FINAL
FRAMING LAYOUT MAY VARY BASED UPON TRUSS MANUFACTURER'S DESIGN.
ROOF TRUSSES TO BE SPACED AT 48" O.C. MAX. UNLESS SHOWN OTHERWISE.
ROOF TRUSS DESIGN LOADS TO BE AS FOLLOWS:
TOP CHORD LIVE LOAD
TOP CHORD DEAD LOAD
BOTTOM CHORD DEAD LOAD
BOTTOM CHORD LIVE LOAD
UPLIFT LOAD (GROSS)
TOP CHORD DEAD LOAD SHOWN ABOVE INCLUDES 3 PSF FOR TRUSS SELF-WEIGHT.
UNIFORM LOADS INDICATED ABOVE TO BE USED FOR DESIGN OF HIP AND/OR GIRDERS
TRUSSES AS REQUIRED.
MAXIMUM LIVE LOAD DEFLECTION SHALL BE SPAN/240 FOR ROOF TRUSSES.
PERMANENT TRUSS BRIDGING AND TEMPORARY TRUSS BRACING SHALL BE IN
ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
ROOF TRUSSES SHALL BE DESIGNED FOR APPLICABLE WIND LOADS AS INDICATED IN
GENERAL NOTES, IN COMBINATION WITH DEAD LOADS SHOWN ABOVE.
TRUSS TO TRUSS CONNECTIONS SHALL BE DESIGNED BY TRUSS MANUFACTURER.
TRUSS TO STEEL BEARING PLATE CONNECTIONS SHALL BE DESIGNED FOR A MINIMUM OF
3,000 LBS OF UPLIFT AND 300 LBS OF SHEAR (WIND CONTROLS) AT SERVICE LOAD LEVEL
OR AS CALCULATED BY THE TRUSS MANUFACTURER, WHICHEVER IS GREATER.
DRAG STRUT FORCE AT COLUMN LINES 6 AND 9 SHALL BE DESIGNED FOR 80 PLF AT
SERVICE LEVEL (WIND CONTROLS).
CONTRACTOR SHALL COORDINATE WITH APPLICABLE MECHANICAL LOADS AND
CLEARANCES PRIOR TO ORDERING TRUSSES.
TRUSS FRAMING SHALL BE GALVANIZED IN ACCORDANCE WITH A653, G60.
20 PSF
13 PSF
10 PSF
10 PSF (UNINHABITABLE ATTIC)
32 PSF
STRUCTURAL STEEL:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
EXCEPT AS INDICATED, ALL DESIGN FABRICATION AND ERECTION OF STRUCTURAL STEEL
SHALL BE IN ACCORDANCE WITH:
AISC 325-10 STEEL CONSTRUCTION MANUAL, 14TH EDITION
STRUCTURAL STEEL SHALL BE AS FOLLOWS:
2.1. W-SHAPES ASTM A992
2.2. PLATES, ANGLES, CHANNELS, MISC. STEEL ASTM A36
2.3. HSS ASTM A500, Gr. B
3/4" DIAMETER ASTM A325N BOLTS SHALL BE USED IN ALL STRUCTURAL STEEL BOLTED
CONNECTIONS UNLESS NOTED OTHERWISE. TIGHTEN BOLTS TO TENSION REQUIRED BY
AISC.
ANCHOR RODS SHALL BE ASTM F1554 Gr.36 THREADED ON EACH END, WITH HEAVY HEX
NUT AND WASHER AT EACH END UNLESS OTHERWISE NOTED. MINIMUM ANCHOR ROD
LENGTH AND DIAMETER SHALL BE SPECIFIED ON SHEET S-303.
ALL WELDED CONSTRUCTION SHALL BE IN ACCORDANCE WITH AWS D1.1 AND AISC.
WELDING SHALL BE PERFORMED ONLY BY OPERATORS QUALIFIED BY THE AWS STANDARD
QUALIFICATION PROCEDURE TO PERFORM THE PARTICULAR TYPE OF WORK REQUIRED.
MEMBERS EXPOSED TO WEATHER IN FINISHED STRUCTURE, INCLUDING LINTELS AND
MECHANICAL EQUIPMENT SUPPORT FRAMES SHALL BE GALVANIZED AFTER FABRICATION.
STEEL BELOW GRADE SHALL BE PROTECTED BY A MINIMUM OF 3" OF CONCRETE OR 4" OF
MASONRY.
GROUT UNDER BEARING PLATES SHALL BE OF NON-SHRINK, NON-METALLIC
COMPOSITION.
ANGLE FRAME MEMBERS AROUND OPENINGS SHALL BE MITERED, WELDED AND GROUND
SMOOTH. FABRICATE STRUCTURAL STEEL MEMBERS WITH NATURAL CAMBER UP EXCEPT
AS INDICATED. NO SPLICES IN STRUCTURAL FRAMING MEMBERS ARE PERMITTED EXCEPT
AS INDICATED OR APPROVED.
MASONRY NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
CONCRETE MASONRY DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE
WITH ACI 530-11 (BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES) AND ASCE 7-10 (MINIMUM DESIGN LOADS FOR BUILDINGS AND
OTHER STRUCTURES).
TYPICAL UNITS SHALL BE TWO-CELL TYPE UNITS AND LINTELS SHALL BE U-
SHAPED UNITS. BOND BEAM UNITS MAY BE U-SHAPED OR TWO-CELL KNOCK-
OUT BLOCKS.
MORTAR SHALL BE TYPE "S" WITH AN AVERAGE COMPRESSIVE STRENGTH OF
1,800 PSI AT 28 DAYS.
CONCRETE MASONRY SHALL BE GRADE "N" (NORMAL) AS SPECIFIED BY ASTM
C90. NET AREA COMPRESSIVE STRENGTH OF CONCRETE MASONRY UNIT
SHALL BE A MIN. 1,900 PSI. MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f'm)
SHALL BE 1,500 PSI PER TABLE 2 OF ACI 530 SPECIFICATIONS.
GROUT FOR USE IN MASONRY SHALL CONFIRM TO ASTM C476 WITH A MINIMUM
COMPRESSIVE STRENGTH OF 2,000 PSI AT 28 DAYS.
ALL MASONRY SHALL BE LAID IN A RUNNING BOND U.N.O.
ALL CELLS BELOW GRADE SHALL BE FILLED WITH GROUT.
ALL INTERIOR MASONRY WALLS (LOAD BEARING & NON-LOAD BEARING) SHALL
HAVE A MIN. 8 INCH STANDARD BOND BEAM REINFORCED WITH TWO #5 BARS
AT TOP OF WALLS, EXCEPT AS NOTED.
SEE SPECIFICATION SECTION 04 20 00 FOR ADDITIONAL INFORMATION.
No. 29581
S
OU
TH
CAROL IN
A
B
R A D L E Y W. M I N O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G
I N E E R
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N A
V A
L A
IR
S
T A
T
IO
N
C K
D B
Y x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
I T E
C T
U R
E C
E M
S P ro je c t N o
N
P ro je c t M a n a g e r:
B ra d M in o r
N O
N E
09/16/2015
/1
/2
:3 :4
P
M
O F
L
IF
E
S U
P P
O R
T B
U
IL
D
IN
G
D D
P M
/1 /2
D
F A
-1
-D
-0
B W
M
B D
M
B W
M
S-002
J O
IN
T
R E
S E
R V
E B
A S
E F
O R
T W
O R
T H
T
X B
W M
S T
R U
C T
U R
A L G
E N
E R
A L N
O T
E S
A D
D
IT
IO
N
/R E
N O
V A
T
IO
N
STRUCTURAL ABBREVIATIONS
R
REINF. REINFORCEMENT
REQ'D REQUIRED
REV. REVISIONS / REVISED
S
SECT. SECTION
SIM. SIMILAR
S.O.G. SLAB ON GRADE
SL. SLOPE
SPEC. SPECIFICATION
SQ. SQUARE
S.S. STAINLESS STEEL
STD. STANDARD
STL. STEEL
STRUC. STRUCTURAL
T
T&B TOP & BOTTOM
T.O. TOP OF
TRANS. TRANSVERSE
TYP. TYPICAL
U
U.N.O. UNLESS NOTED OTHERWISE
V
VERT. VERTICAL
W
WWF WELDED WIRE FABRIC
W/ WITH
W/O WITHOUT
WP WORKING POINT
STRUCTURAL ABBREVIATIONS
K
KSI KIPS/SQUARE INCH
L
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG. LONGITUDINAL
M
MATL. MATERIAL
MAX. MAXIMUM
MECH. MECHANICAL
MTL METAL
MPH MILE PER HOUR
MIN. MINIMUM
MISC. MISCELLANEOUS
N
N.S. NEAR SIDE
N.I.C. NOT IN CONTRACT
NTS NOT TO SCALE
NO. (#) NUMBER
O
O.C. ON CENTER
O.D. OUTSIDE DIAMETER
P
PL PLATE
LBS. POUNDS
PCF POUNDS/CUBIC FOOT
PSF POUNDS/SQUARE FOOT
PSI POUNDS/SQUARE INCH
PEMB PRE-ENGINEERED METAL
BUILDING
PT PRESSURE TREATED
PROJ. PROJECTION
STRUCTURAL ABBREVIATIONS
E
EA. EACH
E.W. EACH WAY
ELEC. ELECTRICAL OR ELECTRIC
EL. ELEVATION
EQ. EQUAL
E.J. (EXP. JT.) EXPANSION JOINT
EXP. EXPANSION/EXPOSED
EXT. EXTERIOR
F
F.S. FAR SIDE
FT. FEET
FRP FIBER REINFORCED POLYMER
FIN. FINISH
F.F. FINISHED FLOOR
FLR. FLOOR
FTG. FOOTING
G
GA. GAGE OR GAUGE
GALV. GALVANIZED
Gr. GRADE
H
HORIZ. HORIZONTAL
I
IN. INCH
I.D. INSIDE DIAMETER
INT. INTERIOR
J
JT JOINT
STRUCTURAL ABBREVIATIONS
A
A.F.F. ABOVE FINISHED FLOOR
A.B. ANCHOR BOLT
& AND
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
@ AT
B
BLKG. BLOCKING
BTM. BOTTOM
B.O. BOTTOM OF
BRDG. BRIDGING
BLDG. BUILDING
C
CLG. CEILING
CL. CENTERLINE
CLR. CLEAR
COL. COLUMN
CONC. CONCRETE
CMU CONCRETE MASONRY UNIT
CONN. CONNECTION
CONT. CONTINUOUS
C.J. CONTROL JOINT
COORD. COORDINATE
D
DET. DETAIL
Ø DIAMETER
DIM. DIMENSION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P
123456
B
C
D
DS1
DS2
DS4DS4DS4
DS5
DS5
18'-4" 20'-0" 20'-0" 20'-0" 18'-4"
DS3
DS3
EXISTING WF8 STEEL COLUMNS SUPPORTING
STEEL TRUSSES (TYP. OF COLUMN LINES 1 TO 6).
COLUMNS, TRUSSES, AND PURLINS TO REMAIN
INTACT AND UNDAMAGED.
SD201
C1
8'-10" 10'-8" 8'-10" 4'-4 5/8"
DS2
EXISTING DRAIN
AND PIPING TO
REMAIN INTACT
AND UNDAMAGED
29'-7"
3'-4" 6'-11" 3'-4" 3'-0"
DS2
DS7
DS7
8" 10'-8"
DS8
E
DS9
/2
/2
(E X
T E
N T
O F
E N
D W
A L L D
E M
O L
IT
IO
N
P E
R K
E Y
N O
T E
D S
SD201
A1
DS1
DS5
DS3
DS2
LEGEND
EXISTING FOOTING
EXISTING WALL
ITEM TO BE DEMOLISHED
GENERAL NOTES:
1. SEE ARCHITECTURAL AND OTHER
DISCIPLINES' DRAWINGS FOR DEMOLITION
ITEMS AND INFORMATION NOT SHOWN.
2. ALL EXISTING CONDITIONS AND STRUCTURAL
MEMBERS SPECIFIED PER ORIGINAL DESIGN
DRAWINGS AND NON-DESTRUCTIVE SITE
INVESTIGATIONS. CONTRACTOR SHALL VERIFY
EXISTING CONDITIONS PRIOR TO
DEMOLITION/CONSTRUCTION AND NOTIFY
GOVERNMENT PROMPTLY OF ANY
DISCREPANCIES.
123456
A
B
C
D
DS6DS6
DS1
18'-4" 20'-0" 20'-0" 20'-0" 18'-4"
/2
/2
96'-8"
DS1
EXISTING WF8 STEEL COLUMNS SUPPORTING STEEL
TRUSSES (TYP. OF COL LINES 1-6). COLUMNS, TRUSSES,
AND PURLINS TO REMAIN INTACT AND UNDAMAGED.
PORTIONS OF ROOF
FRAMING NOT
SHOWN FOR CLARITY
E
No. 29581
S
OU
TH
CAROL IN
A
B
R A D L E Y W. M I N O
R
L I C E N S E D
P
RO
FESS I ONA L
E N G
I N E E R
SHEET
IDENTIFICATION
1 2 3 4 5
D R
A W
N B
Y
D E
S
IG
N B
Y
S B
M T
B Y
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N A
V A
L A
IR
S
T A
T
IO
N
C K
D B
Y x
D
C
B
A
F
IL
E N
U M
B E
R
P L
O T
S C
A L E
P L
O T
D A
T E
SHEET OF
I ro n H o rs e D r i v e
L a d s o n
S o u th C a ro lin a
.8
.3
E N
G
IN
E E
R
IN
G
A R
C H
I T E
C T
U R
E C
E M
S P ro je c t N o
N
P ro je c t M a n a g e r:
B ra d M in o r
A S