On Sht. AD201 it says to remove standing seam metal roof in its entirety. Does this include the metal decking that is supporting it?
Existing standing seam metal roof is supported directly over existing purlins. There is no metal decking supporting the existing roof. Contractor to remove existing standing seam metal roof with the purlins to remain as indicated in the structural drawings.
Provide metal deck to support new standing seam metal roof as well as fasten the new framing to the existing purlins as indicated in structural drawings (i.e. section C1/S-302).