DRAWINGS.pdf

PDF 21 MB Posted

Attached to
Renovation of the office area of B1656
Solicitation number
FA6675-18-R-0001
Issued by

About this file

DRAWINGS

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

PROJECT LOCATION

PROJECT LOCATION

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

301ST FIGHTER WING

NAVAL AIR STATION JOINT RESERVE BASE

FORT WORTH, TX

CONTRACT NUMBER: FA6643-10-D-0002

TASK ORDER: 5D16

PROJECT: DDPM130004

N O

N E

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :3

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B D

M

B D

M

B W

M

S

G-001

B W

M

C O

V E

R S

H E

E T

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

ADDITION/RENOVATION 301ST

MAINTENANCE SQUADRON BLDG 1656

APRIL 12, 2016

FINAL SUBMITTAL

04/12/2016

# OF

TOTAL SHEET NO. SHEET TITLE

64 MP101 MECHANICAL NEW WORK PIPING PLAN

65 MP401 MECHANICAL NEW WORK PIPING ENLARGED

PLAN

66 M-501 MECHANICAL DETAILS

67 M-502 MECHANICAL DETAILS

68 M-503 MECHANICAL DETAILS

69 M-504 MECHANICAL DETAILS

70 M-601 MECHANICAL SCHEDULES

71 M-602 MECHANICAL SCHEDULES

72 M-701 CONTROLS AND OPERATION

73 M-702 CONTROLS AND OPERATION

74 M-703 CONTROLS AND OPERATION

ELECTRICAL

75 E-001 ELECTRICAL GENERAL NOTES & LEGENDS

76 ES101 ELECTRICAL DEMOLITION SITE PLAN

77 ES102 ELECTRICAL NEW WORK SITE PLAN

78 ED101 ELECTRICAL DEMOLITION PLANS

79 ED102 GROUNDING DEMOLITION PLAN

80 E-101 NEW WORK POWER & COMMUNICATION

PLANS

81 E-102 NEW WORK LIGHTING PLAN

82 E-103 NEW WORK GROUNDING PLAN

83 E-501 LIGHTING SCHEDULE & DETAILS

84 E-502 ELECTRICAL AND COMMUNICATIONS DETAILS

85 E-503 COMMUNICATIONS DETAILS

86 E-601 ELECTRICAL PANEL SCHEDULES

87 E-602 ELECTRICAL PANEL SCHEDULES

88 E-603 ELECTRICAL RISER DIAGRAMS

89 E-701 NEW WORK LIGHTNING PROTECTION PLAN

GRAND TOTAL: 89

# OF

TOTAL SHEET NO. SHEET TITLE

GENERAL

1 G-001 COVER SHEET

CIVIL

2 VF101 EXISTING TOPOGRAPHIC SURVEY

3 CD101 CIVIL DEMOLITION & EROSION CONTROL

PLAN

4 CS101 CIVIL SITE PLAN

5 CG101 CIVIL GRADING & STORM DRAINAGE PLAN

6 C-501 CIVIL DETAILS

7 C-502 CIVIL DETAILS

8 C-503 CIVIL DETAILS

STRUCTURAL

9 S-001 STRUCTURAL GENERAL NOTES

10 S-002 STRUCTURAL GENERAL NOTES &

ABBREVIATIONS

11 SD101 STRUCTURAL DEMOLITION PLAN

12 S-101 STRUCTURAL NEW WORK FOUNDATION PLAN

13 S-102 STRUCTURAL NEW WORK FRAMING PLAN

14 S-301 STRUCTURAL SECTIONS

15 S-302 STRUCTURAL SECTIONS

16 S-303 STRUCTURAL SECTIONS

17 S-501 TYPICAL STRUCTURAL DETAILS

18 S-502 TYPICAL STRUCTURAL DETAILS

ARCHITECTURAL

19 A-001 GENERAL NOTES & LEGENDS

20 A-002 GENERAL LEGENDS

21 A-003 PARTITION TYPES & DETAILS

22 AD101 DEMOLITION FIRST FLOOR PLAN

23 AD102 DEMOLITION ROOF PLAN

24 AD201 DEMOLITION EXTERIOR ELEVATIONS

25 A-101 ARCHITECTRUAL NEW WORK FLOOR PLAN

26 A-102 REFLECTED CEILING PLAN

27 A-103 ARCHITECTRUAL NEW WORK ROOF PLAN

28 A-201 EXTERIOR ELEVATIONS

29 A-202 INTERIOR ELEVATIONS

30 A-301 BUILDING CROSS SECTION

31 A-401 ENLARGED FLOOR PLANS

32 A-501 WALL DETAILS

33 A-502 ROOF DETAILS

34 A-601 FINISH SCHEDULE & DETAILS

35 A-602 SIGNAGE SCHEDULE & DETAILS

36 A-603 DOOR SCHEDULE & DETAILS

37 A-604 WINDOW SCHEDULE & DETAILS

38 I-101 FLOORING PLAN

39 I-102 FURNITURE PLAN

40 I-103 SIGNAGE PLAN

FIRE PROTECTION

41 FA001 FIRE ALARM GENERAL NOTES, LEGENDS, &

DIAGRAMS

42 FD101 FIRST FLOOR DEMOLITION FIRE PROTECTION

PLAN

43 FA101 FIRST FLOOR NEW WORK FIRE ALARM PLAN

44 FX001 FIRE SUPPRESSION GENERAL NOTES,

LEGENDS, & DIAGRAMS

45 FX101 FIRST FLOOR NEW WORK FIRE SUPPRESSION

PLAN

46 LP101 LIFE SAFETY PLAN

PLUMBING

47 P-001 GENERAL NOTES & LEGENDS

48 PD101 PLUMBING SANITARY DEMOLITION PLAN

49 PD102 PLUMBING DOMESTIC DEMOLITION PLAN

50 PD103 PLUMBING PIPING DEMOLITION

51 PD401 PLUMBING DEMOLITION ENLARGED PLAN

52 P-101 PLUMBING SANITARY NEW WORK PLAN

53 P-102 PLUMBING DOMESTIC NEW WORK PLAN

54 P-401 PLUMBING NEW WORK ENLARGED PLANS

55 P-501 PLUMBING DETAILS

56 P-502 PLUMBING DETAILS

57 P-601 PLUMBING SCHEDULES

58 P-701 PLUMBING ISOMETRIC PLAN

MECHANICAL

59 M-001 GENERAL NOTES & LEGENDS

60 MD101 MECHANICAL DEMOLITION PLAN

61 MD401 MECHANICAL DEMOLITION ENLARGED PLAN

62 MH101 MECHANICAL NEW WORK PLAN

63 MH401 MECHANICAL NEW WORK ENLARGED PLAN

INDEX OF DRAWINGS

P

LAN

N O

R

TH

SCALE: NOT TO SCALE

STATE MAP

SCALE: NOT TO SCALE

BASE MAP

SCALE: NOT TO SCALE

LOCATION MAP

PLAN NORTH

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

GENERAL NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

THE STRUCTURE IS DESIGNED AS A STABLE UNIT AFTER ALL COMPONENT PARTS

ARE IN PLACE. THEREFORE, THE CONTRACTOR/ERECTOR SHALL PROVIDE ALL

NECESSARY SHORING AND BRACING AS REQUIRED TO ENSURE STABILITY DURING

ERECTION.

WHEN A DETAIL IS SHOWN ON THE STRUCTURAL DRAWINGS FOR ONE CONDITION,

IT SHALL APPLY TO ALL SIMILAR OR LIKE CONDITIONS, UNLESS NOTED OR SHOWN

OTHERWISE ON THE DRAWINGS.

DESIGN CRITERIA:

A: FLOOR LIVE LOAD:

OFFICE

LOCKER ROOM AND RESTROOM

B: ROOF LIVE LOAD:

C: GROUND SNOW LOAD, Pg:

D: WIND LOADS

a. ULTIMATE WIND SPEED, Vult:

b. NOMINAL WIND SPEED, Vasd:

c. RISK CATEGORY:

d. WIND EXPOSURE:

e. INTERNAL PRESSURE COEFFICIENT:

f. PRESSURE COEFFICIENT ZONE WIDTH, a:

g. COMPONENT AND CLADDING WIND PRESSURE:

EFFECTIVE AREAS: 20 SF

ROOF:

WALL:

E: SEISMIC LOADS

a. RISK CATEGORY:

b. SEISMIC IMPORTANCE FACTOR, Ie:

c. MAPPED SPECTRAL RESPONSE,

d. SITE CLASS:

e. DESIGN SPECTRAL RESPONSE,

f. SEISMIC DESIGN CATEGORY:

g. BASIC SEISMIC FORCE RESISTING SYSTEM:

INTERMEDIATE REINFORCED

MASONRY SHEAR WALLS

h. RESPONSE MODIFICATION COEFFICIENT,

i. SEISMIC RESPONSE COEFFICIENT, Cs:

j. DESIGN BASE SHEAR (ADDITION):

k. ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE

THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH IBC 2012, ASCE 7-10, UFC 3-

301-01, AND UFC 4-010-01.

STEEL DECK SHALL BE MINIMUM 3 SPAN CONDITION WITH THE FOLLOWING

MINIMUM PROPERTIES.

ROOF:

TYPE 1.5B22

In = 0.183 in^4/ft. Ip = 0.155 in^4/ft.

Sn = 0.192 in^3/ft. Sp = 0.186 in^3/ft. Fy = 40 ksi

CONTRACTOR SHALL FULLY COORDINATE ALL ARCHITECTURAL AND STRUCTURAL

DRAWINGS (INCLUDING DIMENSIONS AND ELEVATIONS) AND SHALL FULLY

RESOLVE ANY CONFLICTS PRIOR TO COMMENCING WORK.

FABRICATION DRAWINGS SHALL NOT BE REPRODUCTION OF STRUCTURAL

CONTRACT DRAWINGS.

MISCELLANEOUS STRUCTURAL ITEMS, CONDITIONS OR PIECES OF STEEL MAY BE

SHOWN ON ARCHITECTURAL DRAWINGS.

CONTRACTOR SHALL CONSULT ROICC FOR DIRECTION SHOULD UNCHARTED OR

INCORRECTLY CHARTED PIPING OR OTHER UTILITIES BE ENCOUNTERED DURING

SITE CLEARING, GRADING AND EXCAVATION.

50 PSF

50 PSF

20 PSF

5 PSF

115 MPH

89 MPH

II

C ±0.18

3.0 FT

ZONE 1: 12 PSF -30 PSF

ZONE 2: 12 PSF -47 PSF

ZONE 3: 12 PSF -65 PSF

ZONE 4: 30 PSF -32 PSF

ZONE 5: 30 PSF -39 PSF

II

1.00 Ss = 0.09 S1 = 0.05 C Sds = 0.072 Sd1 = 0.057 A

R = 3.5 0.018

2400 LBS

FOUNDATION NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

THE GEOTECHNICAL REPORT IS A SECTION OF THE CONSTRUCTION DOCUMENTS

AND AS SUCH, ALL SOILS AND FOUNDATION WORK SHALL BE DONE IN

ACCORDANCE WITH TERRACON'S GEOTECHNICAL ENGINEERING REPORT FOR

PROPOSED BUILDING 1656 ADDITION AND PARKING LOT EXPANSION - NASJRB

FORT WORTH, TEXAS, PROJECT NUMBER 95155100, DATED OCTOBER 7, 2015.

STRUCTURAL FOUNDATION DESIGN IS BASED UPON AN ALLOWABLE SOIL

BEARING CAPACITY OF 2,500 PSF PER THE GEOTECHNICAL REPORT.

LATERAL SOIL PRESSURE BASED ON SOIL DENSITY OF 120 PCF WITH AN ANGLE

OF INTERNAL REPOSE OF 30 DEGREES.

ALL FOUNDATIONS ARE TO BEAR ON UNDISTURBED IN-SITU SOIL OR ON TESTED

STRUCTURAL BACKFILL. FILL SHALL BE PLACED IN UNIFORM LIFTS OF NO MORE

THAN 8 INCHES THICK AND COMPACTED TO 95% STANDARD PROCTOR VALUE

FOR BACKFILL IN ACCORDANCE WITH ASTM D-698 (THIS INCLUDES THE LAYER OF

CLEAN WASHED SAND OR STONE FOR SLABS ON GRADE). THE MAXIMUM

PARTICLE SIZE FOR FILL PLACEMENT SHALL NOT EXCEED 2/3 OF THE LIFT

THICKNESS.

MAINTAIN POSITIVE SURFACE DRAINAGE TO PREVENT THE ACCUMULATION OF

WATER IN EXCAVATED AREAS.

MATERIAL TO BE USED AS FILL SHALL BE TESTED BY AN APPROVED TESTING

LABORATORY TO DETERMINE SUITABILITY PRIOR TO BEING PLACED.

REMOVE ALL ORGANIC AND DELETERIOUS MATERIAL.

SURFACE AREAS AT GRADE AND AREAS TO RECEIVE FILL SOILS SHALL BE

DETERMINED WITHIN ±2 PERCENTAGE POINTS OF THE OPTIMUM MOISTURE

CONTENT DETERMINED FROM THE STANDARD PROCTOR TEST.

IMMEDIATELY PRIOR TO CONSTRUCTION, SUB GRADE SOILS SHALL BE PROOF

ROLLED WITH A FULLY LOADED TANDEM-AXLE DUMP TRUCK OR SIMILAR

EQUIPMENT TO DETECT ANY UNSTABLE AREAS. THE PROOF ROLLING

EQUIPMENT SHALL MAKE A MINIMUM OF FOUR PASSES OVER EACH SECTION,

WITH THE LAST TWO PASSES PERPENDICULAR TO THE FIRST TWO. ANY AREAS

WHICH PUMP OR RUT SHALL BE UNDERCUT OR SCARIFIED AND DENSIFIED IN

PLACE AND PROOF ROLLED AGAIN CONTRACTOR SHALL NOTIFY ROICC PRIOR

TO COMMENCEMENT OF PROOF ROLLING OPERATIONS.

FILL PLACEMENT SHALL NOT BEGIN UNTIL PROOF ROLLING OPERATIONS ARE

SUCCESSFUL.

CONCRETE DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI

318-11; BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE.

CONCRETE COMPRESSIVE STRENGTH SHALL BE 3,000 PSI MINIMUM AT 28 DAYS.

REINFORCING STEEL SHALL BE ASTM A615, GRADE 60.

WELDED WIRE FABRIC SHALL BE ASTM A1064. WELDED WIRE FABRIC WILL BE

PLACED AT MID DEPTH OF SLAB, UNLESS OTHERWISE NOTED.

PROPORTION AND DESIGN CONCRETE MIXES TO RESULT IN CONCRETE SLUMP

AT POINT OF PLACEMENT NOT LESS THAN 3" AND NOT MORE THAN 5".

ADDITION OF WATER TO READY-MIX IN THE FIELD SHALL NOT BE ALLOWED.

DEPOSIT CONCRETE IN A CONTINUOUS OPERATION UNTIL THE PLACING OF

CONCRETE IS COMPLETE. IF POUR IS TO BE DISCONTINUOUS, CONTRACTOR

SHALL USE CONSTRUCTION JOINTS.

CONCRETE MUST BE CURED FOR A MINIMUM 21 DAYS PRIOR TO ANY ADHESIVE

ANCHOR INSTALLATION.

SEE SECTION 7.7 OF ACI 318 FOR MINIMUM REINFORCED PROTECTION

REQUIREMENTS.

TYPICAL REINFORCEMENT SPLICES SHALL BE AS FOLLOWS:

10.1 #4 BARS - 22" LAP

10.2 #5 BARS - 28" LAP

10.3 #6 BARS - 33" LAP

10.4 #7 BARS - 48" LAP

10.5 #8 BARS - 55" LAP

SEE SPECIFICATION SECTION 03 30 00 FOR ADDITIONAL INFORMATION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

MINIMUM CONCRETE PROTECTION FOR REINFORCEMENT (ACI 318-11, PARA 7.7):

1.

2.

3.

4.

CONCRETE CAST AGAINST AND PERMANENTLY

EXPOSED TO EARTH

CONCRETE EXPOSED TO EARTH OR WEATHER

#6 THROUGH #18

#3 THROUGH #5

CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH EARTH

SLAB, WALLS, JOISTS

#3 THROUGH #11

#14 THROUGH #18

BEAMS, COLUMNS

SHELLS, FOLDED PLATE MEMBERS

#6 THROUGH #18

#3 THROUGH #5

CONCRETE EXPOSED TO MARINE/CORROSIVE ENVIRONMENTS (R.7.7.5)

WALLS & SLABS

OTHER MEMBERS

3"

2" 1 1/2"

3/4" 1 1/2"

1 1/2"

3/4" 1/2"

2" 2 1/2"

CONCRETE NOTES:

MASONRY NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

CONCRETE MASONRY DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE

WITH ACI 530-11 (BUILDING CODE REQUIREMENTS FOR MASONRY

STRUCTURES) AND ASCE 7-10 (MINIMUM DESIGN LOADS FOR BUILDINGS AND

OTHER STRUCTURES).

TYPICAL UNITS SHALL BE TWO-CELL TYPE UNITS AND LINTELS SHALL BE U-

SHAPED UNITS. BOND BEAM UNITS MAY BE U-SHAPED OR TWO-CELL KNOCK-

OUT BLOCKS.

MORTAR SHALL BE TYPE "S" WITH AN AVERAGE COMPRESSIVE STRENGTH OF

1,800 PSI AT 28 DAYS.

CONCRETE MASONRY SHALL BE GRADE "N" (NORMAL) AS SPECIFIED BY ASTM

C90. NET AREA COMPRESSIVE STRENGTH OF CONCRETE MASONRY UNIT

SHALL BE A MIN. 1,900 PSI. MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f'm)

SHALL BE 1,500 PSI PER TABLE 2 OF ACI 530 SPECIFICATIONS.

GROUT FOR USE IN MASONRY SHALL CONFIRM TO ASTM C476 WITH A MINIMUM

COMPRESSIVE STRENGTH OF 2,000 PSI AT 28 DAYS.

ALL MASONRY SHALL BE LAID IN A RUNNING BOND U.N.O.

ALL CELLS BELOW GRADE SHALL BE FILLED WITH GROUT.

ALL INTERIOR MASONRY WALLS (LOAD BEARING & NON-LOAD BEARING) SHALL

HAVE A MIN. 8 INCH STANDARD BOND BEAM REINFORCED WITH TWO #5 BARS

AT TOP OF WALLS, EXCEPT AS NOTED.

SEE SPECIFICATION SECTION 04 20 00 FOR ADDITIONAL INFORMATION.

a a a a h

WALL WIND ZONES GABLE ROOF WIND ZONES (7° < Θ < 45°)

3 3

3 3

2 2

2 2

2 211 a a a aaa

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :1

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-001

B W

M

S T

R U

C T

U R

A L G

E N

E R

A L N

O T

E S

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: NOT TO SCALEA2

WIND DIAGRAMS

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

COLD-FORMED METAL NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

COLD FORMED STEEL DESIGN SHALL BE IN ACCORDANCE WITH THE AISI SPECIFICATION

FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS, 2001 EDITION.

COLD FORMED STEEL SHALL BE DESIGNED FOR WIND LOADING IN GENERAL NOTES.

DESIGN, DETAIL AND ERECT COLD-FORMED METAL FRAMING IN ACCORDANCE WITH ASTM

C955.

COLD-FORMED METAL FRAMING SIZES INDICATED ARE BASED ON A MINIMUM YIELD STRESS

OF 33 KSI.

ALL LOAD BEARING AND SHEAR WALLS SHALL HAVE LATERAL BRIDGING AT MID-HEIGHT OF

STUDS UNLESS NOTED OTHERWISE.

COLD-FORMED METAL FRAMING SHALL BE GALVANIZED IN ACCORDANCE WITH A653, G60.

GALVANIZING DAMAGED BY INSTALLATION OPERATIONS OR WELDING SHALL BE REPAIRED

USING GALVANIZING REPAIR PAINT CONFORMING TO SSPC-PAINT 20 OR DOD-P-21035.

COLD-FORMED METAL FRAMING GAUGES AND SIZES ARE BASED UPON THE STEEL STUD

MANUFACTURERS ASSOCIATION (SSMA).

METAL STUDS FOR BEARING WALLS TO BE 6", GAUGE AS INDICATED.

METAL TRUSS NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

METAL TRUSSES SHALL BE DESIGNED, FABRICATED AND INSTALLED AS INDICATED ON

THE DRAWINGS AND IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE,

NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL

STRUCTURAL MEMBERS 2007 AND AMERICAN IRON AND STEEL INSTITUTE STANDARD FOR

COLD-FORMED STEEL FRAMING - TRUSS DESIGN 2007.

SUBMIT SHOP DRAWINGS AND CALCULATIONS SIGNED AND SEALED BY A REGISTERED

ENGINEER.

PROVIDE HORIZONTAL BRIDGING AS SHOWN ON THE DRAWINGS AND/OR AS

RECOMMENDED BY THE TRUSS MANUFACTURER, WHICHEVER IS GREATER.

THE TRUSS FRAMING SHOWN IS FOR INTENT OF DESIGN PURPOSES ONLY. FINAL

FRAMING LAYOUT MAY VARY BASED UPON TRUSS MANUFACTURER'S DESIGN.

ROOF TRUSSES TO BE SPACED AT 48" O.C. MAX. UNLESS SHOWN OTHERWISE.

ROOF TRUSS DESIGN LOADS TO BE AS FOLLOWS:

TOP CHORD LIVE LOAD

TOP CHORD DEAD LOAD

BOTTOM CHORD DEAD LOAD

BOTTOM CHORD LIVE LOAD

UPLIFT LOAD (GROSS)

TOP CHORD DEAD LOAD SHOWN ABOVE INCLUDES 3 PSF FOR TRUSS SELF-WEIGHT.

UNIFORM LOADS INDICATED ABOVE TO BE USED FOR DESIGN OF HIP AND/OR GIRDERS

TRUSSES AS REQUIRED.

MAXIMUM LIVE LOAD DEFLECTION SHALL BE SPAN/240 FOR ROOF TRUSSES.

PERMANENT TRUSS BRIDGING AND TEMPORARY TRUSS BRACING SHALL BE IN

ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

ROOF TRUSSES SHALL BE DESIGNED FOR APPLICABLE WIND LOADS AS INDICATED IN

GENERAL NOTES, IN COMBINATION WITH DEAD LOADS SHOWN ABOVE.

TRUSS TO TRUSS CONNECTIONS SHALL BE DESIGNED BY TRUSS MANUFACTURER.

TRUSS TO STEEL BEARING PLATE CONNECTIONS SHALL BE DESIGNED FOR A MINIMUM OF

2,000 LBS OF UPLIFT AND 200 LBS OF SHEAR PERPENDICULAR TO THE WALL (WIND

CONTROLS) AT SERVICE LOAD LEVEL OR AS CALCULATED BY THE TRUSS

MANUFACTURER, WHICHEVER IS GREATER.

CONNECTIONS TO RESIST THE DRAG STRUT FORCE AT NEW BUILDING ADDITION WALLS

AS WELL AS THE SHEAR FORCE PARALLEL TO THE WALLS SHALL BE DESIGNED FOR 100

PLF AT SERVICE LEVEL (WIND CONTROLS).

CONTRACTOR SHALL COORDINATE WITH APPLICABLE MECHANICAL LOADS AND

CLEARANCES PRIOR TO ORDERING TRUSSES.

TRUSS FRAMING SHALL BE GALVANIZED IN ACCORDANCE WITH A653, G60.

20 PSF

13 PSF

10 PSF

10 PSF (UNINHABITABLE ATTIC)

32 PSF

STRUCTURAL STEEL:

1.

2.

3.

4.

5.

6.

7.

8.

9.

EXCEPT AS INDICATED, ALL DESIGN FABRICATION AND ERECTION OF STRUCTURAL STEEL

SHALL BE IN ACCORDANCE WITH:

AISC 325-10 STEEL CONSTRUCTION MANUAL, 14TH EDITION

STRUCTURAL STEEL SHALL BE AS FOLLOWS:

2.1. W-SHAPES ASTM A992

2.2. PLATES, ANGLES, CHANNELS, MISC. STEEL ASTM A36

2.3. HSS ASTM A500, Gr. B

3/4" DIAMETER ASTM A325N BOLTS SHALL BE USED IN ALL STRUCTURAL STEEL BOLTED

CONNECTIONS UNLESS NOTED OTHERWISE. TIGHTEN BOLTS TO TENSION REQUIRED BY

AISC.

ALL WELDED CONSTRUCTION SHALL BE IN ACCORDANCE WITH AWS D1.1 AND AISC.

WELDING SHALL BE PERFORMED ONLY BY OPERATORS QUALIFIED BY THE AWS

STANDARD QUALIFICATION PROCEDURE TO PERFORM THE PARTICULAR TYPE OF WORK

REQUIRED.

MEMBERS EXPOSED TO WEATHER IN FINISHED STRUCTURE, INCLUDING LINTELS AND

MECHANICAL EQUIPMENT SUPPORT FRAMES SHALL BE GALVANIZED AFTER FABRICATION.

STEEL BELOW GRADE SHALL BE PROTECTED BY A MINIMUM OF 3" OF CONCRETE OR 4"

OF MASONRY.

GROUT UNDER BEARING PLATES SHALL BE OF NON-SHRINK, NON-METALLIC COMPOSITION.

ANGLE FRAME MEMBERS AROUND OPENINGS SHALL BE MITERED, WELDED AND GROUND

SMOOTH. FABRICATE STRUCTURAL STEEL MEMBERS WITH NATURAL CAMBER UP EXCEPT

AS INDICATED. NO SPLICES IN STRUCTURAL FRAMING MEMBERS ARE PERMITTED EXCEPT

AS INDICATED OR APPROVED.

STEEL JOIST NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

DESIGN, DETAIL AND ERECT STRUCTURAL STEEL JOIST IN ACCORDANCE

WITH SJI RECOMMENDED CODE FOR STANDARD PRACTICE FOR STEEL JOIST

AND JOIST GIRDERS, 2010.

HORIZONTAL BRIDGING FOR K SERIES JOIST SHALL BE CONTINUOUS TOP

AND BOTTOM, ANCHORED AT EACH END, AND BOLTED/WELDED TO EACH

JOIST PER JOIST MANUFACTURER'S RECOMMENDATIONS.

A SINGLE LINE OF BOTTOM CHORD BRIDGING SHALL BE PROVIDED NEAR THE

FIRST BOTTOM CHORD PANEL POINTS FOR UPLIFT AS RECOMMENDED BY

JOIST MANUFACTURER.

ALL BRIDGING AND BRIDGING ANCHORS SHALL BE COMPLETELY INSTALLED

BEFORE CONSTRUCTION LOADS ARE PLACED ON THE JOIST.

THE ENDS OF ALL BRIDGING LINES SHALL TERMINATE AND ANCHOR AT WIDE

FLANGE SECTIONS OR MASONRY WALLS AS INDICATED.

JOIST SHALL BE DESIGNED FOR A WIND UPLIFT GROSS FORCE OF 32 PSF.

CONTRACTOR SHALL PROVIDE FIELD MEASUREMENTS TO JOIST

MANUFACTURER TO COORDINATE AND VERIFY JOIST LENGTH.

SEE GENERAL NOTES FOR ROOF LIVE LOADS.

JOIST MANUFACTURER SHALL CHECK AND PROVIDE SYSTEM FOR POINT

LOADS SHOWN.

JOIST MANUFACTURER SHALL PROVIDE NECESSARY CAMBER TO OFF SET

THE DEAD LOAD OF SUPPORTED ROOFS AND/OR ELEVATED FLOOR

CONCRETE SLAB.

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :1

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-002

B W

M

S T

R U

C T

U R

A L G

E N

E R

A L N

O T

E S

A

B B

R E

V

IA

T

IO

N S

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

STRUCTURAL ABBREVIATIONS

R

REINF. REINFORCEMENT

REQ'D REQUIRED

REV. REVISIONS / REVISED

S

SECT. SECTION

SIM. SIMILAR

S.O.G. SLAB ON GRADE

SL. SLOPE

SPEC. SPECIFICATION

SQ. SQUARE

S.S. STAINLESS STEEL

STD. STANDARD

STL. STEEL

STRUC. STRUCTURAL

T

T&B TOP & BOTTOM

T.O. TOP OF

TRANS. TRANSVERSE

TYP. TYPICAL

U

U.N.O. UNLESS NOTED OTHERWISE

V

VERT. VERTICAL

W

WWF WELDED WIRE FABRIC

W/ WITH

W/O WITHOUT

WP WORKING POINT

STRUCTURAL ABBREVIATIONS

L

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LONG. LONGITUDINAL

M

MATL. MATERIAL

MAX. MAXIMUM

MECH. MECHANICAL

MTL METAL

MPH MILE PER HOUR

MIN. MINIMUM

MISC. MISCELLANEOUS

N

N.S. NEAR SIDE

N.I.C. NOT IN CONTRACT

NTS NOT TO SCALE

NO. (#) NUMBER

O

O.C. ON CENTER

O.D. OUTSIDE DIAMETER

P

PL PLATE

LBS. POUNDS

PCF POUNDS/CUBIC FOOT

PSF POUNDS/SQUARE FOOT

PSI POUNDS/SQUARE INCH

PEMB PRE-ENGINEERED METAL

BUILDING

PT PRESSURE TREATED

PROJ. PROJECTION

STRUCTURAL ABBREVIATIONS

ELEC. ELECTRICAL OR ELECTRIC

EL. ELEVATION

EQ. EQUAL

E.J. (EXP. JT.) EXPANSION JOINT

EXP. EXPANSION/EXPOSED

EXT. EXTERIOR

F

F.S. FAR SIDE

FT. FEET

FRP FIBER REINFORCED POLYMER

FIN. FINISH

F.F. FINISHED FLOOR

FLR. FLOOR

FTG. FOOTING

G

GA. GAGE OR GAUGE

GALV. GALVANIZED

Gr. GRADE

H

HORIZ. HORIZONTAL

I

IN. INCH

I.D. INSIDE DIAMETER

INT. INTERIOR

J

JT JOINT

K

KSI KIPS/SQUARE INCH

STRUCTURAL ABBREVIATIONS

A

A.F.F. ABOVE FINISHED FLOOR

A.B. ANCHOR BOLT

& AND

APPROX. APPROXIMATE

ARCH. ARCHITECTURAL

@ AT

B

BLKG. BLOCKING

BTM. BOTTOM

B.O. BOTTOM OF

BRDG. BRIDGING

BLDG. BUILDING

C

CLG. CEILING

CL. CENTERLINE

CLR. CLEAR

COL. COLUMN

CONC. CONCRETE

CMU CONCRETE MASONRY UNIT

CONN. CONNECTION

CONT. CONTINUOUS

C.J. CONTROL JOINT

COORD. COORDINATE

D

DET. DETAIL

Ø DIAMETER

DIM. DIMENSION

E

EA. EACH

E.W. EACH WAY

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

DS6

DS2

DS5

DS6

DS4

DS3

LOCATE NEW OPENING SUCH

THAT EXISTING LADDER AND

COLUMN TO REMAIN ARE

UNDAMAGED AND DO NOT

INTERFERE WITH NEW DOOR

DS5

DS6

(FULL HEIGHT)

DS6

(2) 45° CUTS AT

INTERIOR OF 7 1/2"

SLAB. DO NOT CUT

A 90° CORNER AT

THIS LOCATION

DS7

REMOVE ALL EXISTING

HOUSEKEEPING PADS

TO SURFACE OF

EXISTING CONC. SLAB

(TYP. IN MECH. ROOM)

DS4

DS4

DS4

EXCAVATE SOIL AND DRILL THROUGH EXISTING

12"± WIDE CONCRETE GRADE BEAM TO

MINIMUM EXTENT POSSIBLE FOR INSTALLATION

OF NEW PIPING. COORDINATE DEPTH AND

LOCATION WITH PLUMBING DRAWINGS.

SEE GENERAL

NOTE 1 (TYP.)

4'-10 1/8" ±

DS6

DS3

DS4

LEGEND

ITEM TO BE DEMOLISHED

EXISTING CMU WALL

DS1 DEMOLITION KEYNOTE

GENERAL NOTES:

1.

2.

SEE ARCHITECTURAL AND OTHER DISCIPLINES'

DRAWINGS FOR DEMOLITION ITEMS AND

INFORMATION NOT SHOWN.

ALL EXISTING CONDITIONS AND STRUCTURAL

MEMBERS SPECIFIED PER ORIGINAL DESIGN

DRAWINGS AND NON-DESTRUCTIVE SITE

INVESTIGATIONS. CONTRACTOR SHALL VERIFY

EXISTING CONDITIONS PRIOR TO

DEMOLITION/CONSTRUCTION AND NOTIFY

GOVERNMENT PROMPTLY OF ANY

DISCREPANCIES.

EXISTING FOOTING

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :5

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

SD101

B W

M

S T

R U

C T

U R

A L D

E M

O L

IT

IO

N

P L A

N

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: 1/4" = 1'-0"A1

STRUCTURAL DEMOLITION PLAN

DEMOLITION KEYNOTES:

NO. DESCRIPTION

DS2 DEMOLISH ENTIRE EXISTING METAL PANEL FULL

HEIGHT AND RELATED ITEMS.

DS3 SAW CUT EXISTING CMU WALL FOR INSTALLATION

OF NEW VERTICAL REINFORCEMENT. SEE SHEET

S-502 & COORDINATE LOCATIONS WITH S-302.

DS4 SAW CUT AND DEMOLISH EXISTING 5" OR 7 1/2"

CONCRETE SLAB ON GRADE FOR INSTALLATION OF

NEW SANITARY PIPING. COORDINATE WITH

PLUMBING DRAWINGS. DO NOT SAWCUT EXISTING

CONCRETE GRADE BEAMS.

DS5 DEMOLISH EXISTING FUEL TANK AND CANOPY.

COORDINATE WITH ARCHITECTURAL.

DS6 SELECTIVELY SAWCUT AND/OR DEMOLISH EXISTING

MASONRY WALL FOR NEW OPENING. SEE

CORRESPONDING NEW WORK AND COORDINATE

WITH ARCHITECTURAL.

DS7 SAWCUT EXISTING EXTERIOR SLAB FOR

INSTALLATION OF NEW CONC. STOOP/RAMP.

PLAN NORTH

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

GRAPHIC SCALE

KEYPLAN

AREA SHOWN

AREA SHOWN

NO OTHER STRUCTURAL DEMOLITION

WORK WITHIN HANGAR AREA U.N.O.

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

CJ CJ

CJ CJ

C J

C J

C J

C J

C J

C J

C J

C J

CJ CJCJ CJ CJ CJ CJ CJ

C J

C J

C J

C J

C J

C J

C J

C J

CJCJCJCJ

A1

S-302

S2

S2

S3

S3

S2

S1

S2

S3

S4

S4

C1

S-301

S5

S4

A3 S-302

B1 S-303

/8

S12

S12

S2

S1

S5(7 1/2"±)

(5"±)

5'-0 3/8"

S4

S4

S4

S14

S4

S4

S13

S2

S15S15

A2

S-301

S3

EXISTING CMU

CONTROL JOINT

S5(5"±)

S5(5"±)

4'-8"

EXISTING LADDER

AND COLUMN

S16

MATCH EXISTING DRIVE

ELEVATION THIS SIDE (SEE CIVIL)

S13

SEE GENERAL

NOTE 1 (TYP.)

S16

58'-8" 2'-8"

LEGEND

CONTROL JOINT. SEE SHEET S-501

NEW CMU WALL

EXISTING CMU WALL

NEW FOOTING

EXISTING FOOTING

NEW CONCRETE PATCH

GENERAL NOTE:

1. SEE ARCHITECTURAL AND OTHER DISCIPLINES'

DRAWINGS FOR ITEMS AND INFORMATION NOT

SHOWN.

2. FINISHED FLOOR ELEVATION 0'-0" INDICATED ON

THE STRUCTURAL DRAWINGS CORRESPONDS TO

TOP OF EXISTING SLAB ON GRADE.

NEW WORK KEYNOTES1

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :2

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S

S-101

B W

M

S T

R U

C T

U R

A L N

E W

W O

R K

F O

U N

D A

T

IO

N P

L A

N

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: 1/4" = 1'-0"A1

STRUCTURAL NEW WORK FOUNDATION PLAN

NEW WORK KEYNOTES:

NO. DESCRIPTION

S1 NEW 5" CONCRETE SLAB ON GRADE W/

6x6-W2.9xW2.9 WWF. T.O. NEW CONCRETE SLAB

ELEVATION TO MATCH EXISTING FLOOR ELEVATION.

S2 NEW CONT. x 2'-4" x 12" CONCRETE STRIP FOOTING

W/ 3-#5 CONT. & #3 @ 32" O.C. TRANS. T.O. FOOTING

EL.-2'-0".

S3 NEW METAL PANEL AND 8" CMU WALL W/ #5

VERTICAL @ 32" O.C. FILL CELLS W/ GROUT. HORIZ.

W1.7 LADDER REFINF. @ 16" O.C.

S4 1/2" EXPANSION JOINT W/ SEALANT MATERIAL

BETWEEN NEW CONCRETE SLABS ON GRADE AND

NEW/EXISTING WALLS.

S5 NEW 5"± OR 7 1/2"± CONCRETE SLAB ON GRADE TO

MATCH EXISTING CONCRETE SLAB ELEVATION AND

THICKNESS.

S12 REINFORCE EXISTING CMU CELLS PER DETAIL ON

S-502. COORDINATE LOCATION AND NUMBER OF

CELLS TO BE FILLED WITH CORRESPONDING

SECTIONS.

S13 NEW 8" CMU INFILL REINFORCED PER S-502. DRILL

AND EPOXY REBAR 5" INTO EXISTING FOOTING @

24" O.C. (TOTAL OF 2).

S14 8" x 8" THICKENED SLAB EDGE WITH 1-#5 CONT. AT

DOORWAY.

S15 1/2" EXPANSION JOINT W/ SEALANT MATERIAL

BETWEEN NEW AND NEW/EXISTING WALLS.

S16 PROVIDE NEW CONC. SLAB/RAMP AT NEW DOOR.

SEE SECTION A2/S-301 FOR THICKNESS & REINF.

PLAN NORTH

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

GRAPHIC SCALE

KEYPLAN

AREA SHOWN

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

A1

S-302

S3

S3

S3

S3

C1 S-301

S-102

C1

B1

S-301

A3

S-302

B1

S-303

A1

S-303

58'-8" 2'-8"

NEW MECHANICAL UNIT ON EXISTING MEZZANINE

SEE S-301 FOR RIDGE

LOCATION (NOT SHOWN)

S17

S17

/8

S6S11

S7

S11 S8

S10 S10

S10S10

10'-0"

NEW DOOR OPENING. COORDINATE

EXACT LOCATION WITH EXISTING

COLUMN AND MEZZANINE/LADDER.

LOCATE NEW UNIT

SUPPORT POINTS/CURB

ON EXISTING STEEL

MEMBERS AND NOT ON

EXISTING GRATING ALONE.

3'-8"2'-7 1/2"

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :2

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-102

B W

M

S T

R U

C T

U R

A L N

E W

W O

R K

F R

A M

IN

G

P L A

N

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: 1/8" = 1'-0"A1

STRUCTURAL NEW WORK FRAMING PLAN

NEW WORK KEYNOTES:

NO. DESCRIPTION

S3 NEW METAL PANEL AND 8" CMU WALL W/ #5

VERTICAL @ 32" O.C. FILL CELLS W/ GROUT. HORIZ.

W1.7 LADDER REFINF. @ 16" O.C.

S6 NEW PRE-ENGINEERED LIGHT GAUGE METAL

TRUSSES @ 48" O.C. MAX. SEE S-002 FOR

ADDITIONAL INFORMATION.

S7 NEW 8K1 STEEL JOISTS @ 48" O.C. MAX.

S8 NEW STEEL CHANNELS (14'-0" LONG, NOT SHOWN)

AT EXISTING CMU WALL LOCATION TO SUPPORT

EXISTING AND NEW ROOF JOISTS.

S10 PLACE NEW FANS AT BOTTOM CHORD PANEL

POINTS OF EXISTING TRUSS. SEE S-301.

S11 NEW 1.5B22 METAL DECK OVER NEW TRUSSES AND

NEW BAR JOISTS. SEE S-502 FOR FASTENING

DETAIL AND SEE SECTIONS FOR ROOF ASSEMBLY.

S17 DRAG STRUT TRUSS. SEE S-002 FOR FORCE

INFORMATION.

PLAN NORTH

164 8268

SCALE: 1/8"=1'-0"

GRAPHIC SCALES

SCALE: 1/4" = 1'-0"

S-102

C1

ENLARGED MEZZANINE PLAN

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

F.F 0"

T.O.F -2' - 0"

T.O. CMU

11' - 4"

8" CMU WALL W/ #5 VERT.

@ 32" O.C. FILL CELLS

WITH GROUT. HORIZ. W1.7

LADDER REINF. @ 16" O.C.

CONT. 8" CMU BOND BEAM

W/ 2-#5 CONT. @ T.O. WALL

8" CMU WALL W/ #5 VERT.

@ 32" O.C. FILL CELLS

WITH GROUT. HORIZ. W1.7

LADDER REINF. @ 16" O.C.

8" CMU BOND BEAM

W/ 2-#5 CONT.

8" CMU LINTEL W/ 2-#5 CONT.

2'-4"

2'-4"

5" CONCRETE SLAB ON GRADE

W/ 6x6-W2.9xW2.9 WWF.

T.O. SLAB ELEVATION TO MATCH

EXISTING SLAB ELEVATON

4" UNIFORMLY GRADED

COURSE GRAVEL FILL

COMPACTED SUBGRADE

95% ASTM D-698 (TYP.)

10 MIL VAPOR

RETARDER

CONT. x 2'-4" x 12" CONC.

FOOTING W/ 3-#5 CONT.

& #3 @ 32" O.C. TRANS.

1/2" EXPANSION MATERIAL

1/2" EXPANSION MATERIAL

PRE-ENGINEERED METAL

TRUSSES @ 48" O.C. MAX.

1.5B22 METAL DECK

RIGID INSULATION. SEE ARCH

STANDING SEAM METAL ROOF. SEE ARCH

TRUSS BEARING PLATE

@ EACH END OF TRUSS.

SEE SHEET S-501

TRUSS BEARING PLATE

@ EACH END OF TRUSS.

SEE SHEET S-501

CONT. x 2'-4" x 12" CONC.

FOOTING W/ 3-#5 CONT.

& #3 @ 32" O.C. TRANS.

1 1/2"

12"

1 1/2"

12"

E X

IS

T

IN

G

J O

IS

T

B E

A R

IN

G

E L E

V A

T

IO

N

J O

IS

T

S E

A T

/2

E X

IS

T

IN

G

33'-7 3/4" ± COORDINATE W/ EXISTING AND ARCH.25'-1 3/4" ± COORDINATE W/ EXISTING AND ARCH.

2'-8"

CONT. 8" CMU BOND BEAM W/

2-#5 CONT. @ WINDOW SILL

SEE ARCH FOR

SOFFIT DETAILS

BLOCKING PANELS OR

SIMILAR PERPENDICULAR

TO TRUSSES FOR

LATERAL LOAD

TRANSFER BY TRUSS

MANUFACTURER (TYP.)

FIELD VERIFY AND MATCH EXISTING (TYP.)

B.O. TRUSS

27' - 4"

NEW FAN (TYP. OF 4).

SEE MECHANICAL. FASTEN TO

EXISTING BOTTOM CHORD

PANEL POINTS OF TRUSS

EXISTING STEEL TRUSS

S-301

A1

EXISTING TRUSS TOP

CHORD (BACK-TO-BACK

STEEL ANGLES)

EXISTING TRUSS BOTTOM

CHORD (BACK-TO-BACK

STEEL ANGLES)

CLAMP-TYPE MOUNTING

BRACKET BY MANUFACTURER.

DO NOT DRILL INTO OR

DAMAGE EXISTING TRUSS

EXISTING ROOF JOIST SEAT

EXISTING TRUSS WEB

MEMBERS (BACK-TO-

BACK STEEL ANGLES)

MOUNT BRACKET TO

EXISTING BOTTOM

CHORD PANEL POINT

F.F 0"

T.O.F -2' - 0"

#5 SLAB DOWELS @ 16" O.C.

AT DOORWAY

5" CONCRETE SLAB ON GRADE W/ 6x6-W2.9xW2.9 WWF.

T.O. SLAB ELEVATION TO MATCH EXISTING SLAB ELEVATON

4" UNIFORMLY GRADED

COURSE GRAVEL FILL

COMPACTED SUBGRADE

95% ASTM D-698 (TYP.)

10 MIL VAPOR RETARDER

CONT. x 2'-4" x 12" CONC.

FOOTING W/ 3-#5 CONT.

& #3 @ 32" O.C. TRANS.

8" x 8" THICKENED SLAB W/

1-#5 CONT. AT DOORWAY

(1/2" CHAMFER)

GROUT ALL CELLS

BELOW GRADE (TYP.)

NEW CONC. RAMP

W/ 1/2" EXP.

MATERIAL (8" MIN.)

2'-4"

/2

NEW STOOP/RAMP END TO

MATCH EXISTING DRIVE

ELEVATION (SEE CIVIL)

#5 @ 12" O.C. E.W.#5 @ 12" O.C. E.W.

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :3

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-301

B W

M

S T

R U

C T

U R

A L S

E C

T

IO

N S

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

04 8268 02 4 8134

SCALE: 1/4"=1'-0"

GRAPHIC SCALES

SCALE: 3/8" = 1'-0"

S-101

C1

BUILDING SECTION

SCALE: 1/4" = 1'-0"

S-102

B1

HANGAR SECTION

SCALE: 3/4" = 1'-0"

S-301

A1

FAN MOUNTING DETAIL

SCALE: 3/8"=1'-0"

24 4

SCALE: 3/4"=1'-0"

12 2

S-102

SCALE: 3/4" = 1'-0"

S-101

A2

SECTION @ DOORWAY

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

F.F

T.O.F -2' - 0"

(2) - MC12x14.3 W/ 1/2"Ø

THRU BOLTS SPACED AS

SHOWN ON S-303

EXISTING PORTION OF 8"

CMU TO REMAIN

/8

/8

CONT. 8" CMU BOND

BEAM W/ (2) #5 CONT.

(APPROX. 11" ± TALL)

8" CMU WALL W/ #5 @ 32" O.C.

VERTICAL. FILL CELLS W/

GROUT. HORIZ. W1.7 LADDER

REINF. @ 16" O.C.

1/2" EXPANSION MATERIAL

5" CONC. SLAB ON GRADE

W/ 6x6-W2.9xW2.9 WWF

EXISTING 8" CMU WALL

BEYOND

NEW 8K1 JOIST @ 48" O.C.

EXISTING 10K1 JOISTS

@ 48" O.C. (TYP.)

NEW 8K JOIST TO BEAR ATOP

NEW PLATE DRILLED & EPOXY

INTO EXISTING CMU BOND BEAM.

SEE S-501 FOR NEW BEARING

PLATE INSTALLATION (TYP.)

JOIST BEARING PLATE

@ EACH END OF JOIST.

SEE SHEET S-501

CONT. x 2'-4" x 12" CONC.

FOOTING W/ 3-#5 CONT.

& #3 # 32" O.C. TRANS.

COMPACTED SUBGRADE

95% ASTM D-698

GROUT ALL CELLS

BELOW GRADE (TYP.)

FINISH GRADE

DOWEL TO MATCH

VERTICAL

REINFORCEMENT

EXISTING 7 1/2" CONC.

SLAB (FIELD VERIFY)

EXISTING 12" x 30" CONC.

GRADE BEAM4" UNIFORMLY GRADED

COURSE GRAVEL FILL

10 MIL VAPOR RETARDER

B1

S-303

EXISTING REINF. 8" BOND

BEAM & BEARING PLATE

2'-4"

1 1/2"

12"1.5B22 METAL DECKING SUPPORTING

RIGID INSULATION AND STANDING

SEAM METAL ROOFING (SEE

ARCHITECTURAL). SEE S-502 FOR

DECK FASTENING DETAIL.

1 1/2" 12"

S-102

/8

FIELD VERIFY AND MATCH EXISTING (TYP.)

F.F 0"

1'-8"

"2

1'-4"

2"

(2) 1/4" STIFFENER

PLATES (TYP.)

(2) - MC12x14.3 W/ 1/2"Ø THRU BOLTS

SPACED AS SHOWN ON S-303

DRILL AND EPOXY 5"

INTO EXISTING SLAB

(TYP. OF 2 LOCATIONS)

AT CONTRACTOR OR

BASE OPTION, (6) NEW

3/4"Ø x 6" LONG SIMPSON

TITEN HD BOLTS INTO

NEWLY GROUTED CMU

CELLS (5-1/2" MIN.

EMBEDMENT)

EXISTING BOND BEAM AND CMU

WALL TO REMAIN IN PLACE

EXISTING STEEL JOISTS (NOT

SHOWN) AND BEARING PLATE

TO REMAIN IN PLACE AND

UNDAMAGED (TYP.)

ADD NEW #5 VERTICAL

REBAR AND GROUT CELL.

SEE SHEET S-502.

DRILL AND EPOXY 5" INTO

EXISTING BOND BEAM

(TYP. OF 3 LOCATIONS)

EXISTING CONC. SLAB

& GRADE BEAM

/8

B

.O M

C

S-102 S-303

14" x 4" x 1/4" x 1'-8"

LONG BENT PLATE W/

(6) 3/4"Ø THRU BOLTS

EXISTING ROOFING

EXISTING CMU

CONTROL JOINT

2"

THESE 2 HOLES SHALL

BE 1-1/4" HORIZONTAL

LONG SLOTTED HOLES

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :3

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-302

B W

M

S T

R U

C T

U R

A L S

E C

T

IO

N S

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: 3/4"=1'-0"

12 2

GRAPHIC SCALE

SCALE: 3/4" = 1'-0"

S-101

A1

SECTION

SCALE: 3/4" = 1'-0"

S-101

A3

BEAM CONNECTION @ LOCKER ROOM

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

A3

S-302

(MC12 TO WALL)

1/2" GAP

(2) 1/4" STIFFENER

PLATES (TYP.)

3"x1/4"x0'-3" WASHER @ EXPOSED CMU END (2) - MC12x14.3 W/ 1/2"Ø THRU

BOLTS SPACED AS SHOWN

DRILL AND EPOXY NEW REBAR 5" INTO

EXISTING CONC. FOUNDATION (TYP.)

AT CONTRACTOR OR BASE OPTION, (6)

NEW 3/4"Ø x 6" LONG SIMPSON TITEN

HD BOLTS INTO NEWLY GROUTED CMU

CELLS (5-1/2" MIN. EMBEDMENT)

EXISTING BOND BEAM AND CMU

WALL TO REMAIN IN PLACE

EXISTING STEEL JOISTS AND

BEARING PLATE REMAIN IN

PLACE AND UNDAMAGED (TYP.)

NEW 8K JOIST TO BEAR ATOP NEW

PLATE DRILLED & EPOXY INTO EXISTING

CMU BOND BEAM. SEE S-501 FOR NEW

BEARING PLATE INSTALLATION (TYP.)

ADD NEW #5 VERTICAL REBAR AND

GROUT CELL. SEE SHEET S-502.

DRILL AND EPOXY 5" INTO

EXISTING BOND BEAM (TYP.

OF FOUR LOCATIONS)

EXISTING CONC. SLAB

EXISTING CONC. GRADE BEAM

EXISTING HANGAR

CONC. SLAB

11'-8" 6'-4" 3'-4" 4'-0"

DRILL AND EPOXY NEW REBAR

5" INTO EXISTING BOND BEAM

(NOT SHOWN)

J O

IS

T

B E

A R

IN

G

E L E

V A

T

IO

N

NEW OPENING.

SEE S-501 FOR

PENETRATION

LINTEL DETAIL

EXPANSION JOINT (SEE ARCH FOR

DETAILS AND MEMBERS NOT SHOWN)

NEW PRE-ENGINEERED METAL

TRUSSES @ 48" O.C. MAX.

EXISTING CMU WALL

14" x 4" x 1/4" x 1'-8"

LONG BENT PLATE W/

(6) 3/4"Ø THRU BOLTS

SEE SECTION A1/S-303

1.5B22 METAL DECKING SUPPORTING RIGID

INSULATION AND STANDING SEAM METAL

ROOFING (SEE ARCHITECTURAL). SEE S-502

FOR DECKING FASTENING DETAIL.

TRUSS TO ANGLE

FASTENING BY THE

TRUSS MANUFACTURER.

14'-0" (MC 12 LENGTH)

/8

4" 1'-4" 1'-4" 2'-0" 2'-0" 2'-0" 2'-0" 1'-4" 1'-4" 4"

/8

1'-4"

ALIGN (4) BOLTS THIS

END WITH NEWLY FILLED

CELLS AS SHOWN

CONT. WELD MC12

TO BENT PLATE (TYP.)

DRAG STRUT TRUSS

SEE ARCH FOR DETAILS

AND MEMBERS NOT

SHOWN AT RAKE

T.O. CMU

11' - 4"

GABLE END (DRAG STRUT) TRUSS.

BRACE TO ADJACENT TRUSSES PER

MANUFACTURER'S RECOMMENDATIONS

TRUSS BEARING PLATE @ 48" O.C. UNDER

GABLE END TRUSS. SEE SHEET S-501

TRUSS TO BEARING PLATE CONNECTIONS

BY TRUSS MANUFACTURER (TYP.)

SEE S-002 FOR DRAG STRUT

FORCE LOAD INFORMATION

NEW 8K1 JOIST

@ 48" O.C. MAX.

1.5B22 METAL DECK

WELDED TO CONT. ANGLE

L2x2x1/4 x 4" CLIP

@ 48" O.C. MAX W/

(2) 1/2"Ø x 5" TITEN

HD BOLTS

BRIDGING BY JOIST

MANUFACTURER

PRE-ENGINEERED

METAL TRUSSES

@ 48" O.C. MAX.

L2x2x1/4 W/ (2) 1/2"Ø x 5" TITEN

HD BOLTS

WELD BRIDGING

TO L2x2x1/4

NEW CONT. L6x4x5/16 (LLV) W/

3" VERT. LONG-SLOTTED

HOLES. INSTALL NEW 1/2"Ø x 6"

ADHESIVE BOLTS @ EACH

EXISTING GROUTED CELL. DO

NOT OVER-TIGHTEN NUT AS

VERTICAL MOVEMENT MUST BE

ALLOWED. FIELD LOCATE

EXISTING FILLED CELLS PRIOR

TO FABRICATION

CONT. L2-1/2x2-1/2x1/4

1.5B22 METAL DECKING SUPPORTING RIGID INSULATION AND

STANDING SEAM METAL ROOFING (SEE ARCHITECTURAL).

SEE S-501 FOR DECKING FASTENING DETAIL.

EXPANSION JOINT (SEE

ARCH FOR DETAILS AND

MEMBERS NOT SHOWN)

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :4

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-303

B W

M

S T

R U

C T

U R

A L S

E C

T

IO

N S

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: 3/4"=1'-0"

12 2

GRAPHIC SCALE

SCALE: 3/4" = 1'-0"

S-101

B1

BEAM @ LOCKER ROOM DETAIL

SCALE: 3/4" = 1'-0"

S-102

A1

SECTION

S-102 S-302

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

CMU BOND BEAM

NOTES:

5"x3/8"x8" STEEL

BEARING PLATE W/ (2)

1/2"Φ x 6" NELSON STUDS

1. ENSURE POSITIVE BEARING BETWEEN PLATE AND GROUT FILL.

2. ENSURE PLATE BEARS ON GROUT FILL. DO NOT BEAR PLATE ON BOND BEAM WALLS.

3. TRUSS TO PLATE CONNECTIONS PER TRUSS MANUFACTURER.

8"

4"

EXISTING CMU BOND BEAM

5"x3/8"x8" STEEL BEARING

PLATE. DRILL AND EPOXY

(2) 1/2"Φ ANCHOR RODS

8"

4"

POST-INSTALLED ROD

NEW CONSTRUCTION

RODS WELDED TO PLATE

1. INSTALL CONTROL JOINTS SUCH THAT NO DIMEMSION BETWEEN

JOINTS EXCEEDS 16' OR 3t MEASURED IN FEET, WHICHEVER IS LESSER (i.e. FOR A t = 4" THICK SLAB, MAX. CONTROL JOINT

SPACING = 3*4 = 12') UNLESS NOTED OTHERWISE.

2. INSTALL CONTROL JOINTS SUCH THAT THE RECTANGULAR

SECTIONS CREATED BETWEEN THE JOINTS DO NOT EXCEED A

1:1.5 MAXIMUM RATIO (i.e. 10'x15' SECTION).

1/8" t/

4SAWCUT & FILL

WITH SEALANT

t

COMPACTED SUBGRADE

UNIFORMLY GRADED

COURSE GRAVEL FILL

VAPOR RETARDER

NOTES:

STEEL ANGLE PER

STEEL LINTEL SCHEDULE

EXISTING CMU WALL

CONCEALED STEEL LINTEL SCHEDULE

OPENING SIZE

16" TO 54"

55" TO 90"

6" CMU

(2) L3-1/2x2-1/2x1/4

(2) L5x3x1/4 LLV

8" CMU

(2) L3-1/2x3-1/2x5/16

(2) L5x3-1/2x5/16 LLV

10" CMU

(2) L5x5x5/16

(2) L5x5x5/16

12" CMU

(2) L6x6x5/16

(2) L6x6x5/16

SAWCUT MORTAR JOINT TO

MID-DEPTH & INSERT ANGLE

(COMPLETE ONE SIDE PRIOR

TO COMMENCING WORK ON

OPPOSITE SIDE)

LENGTH OF SAWCUT SHALL BE

REQUIRED OPENING LENGTH

PLUS 16" MIN. (8" MIN. PER SIDE)

VISIBLE STEEL LINTEL OPTION CONCEALED STEEL LINTEL OPTION

BACK TO BACK STEEL ANGLES

PER STEEL LINTEL SCHEDULE

EXISTING CMU WALLSAWCUT & DEMOLISH

EXISTING CMU TO MID-DEPTH

& INSERT ANGLE AND FASCIA

CMU (COMPLETE ONE SIDE

PRIOR TO COMMENCING

WORK ON OPPOSITE SIDE)

LENGTH OF DEMOLITION SHALL BE

REQUIRED OPENING LENGTH PLUS

16" MIN. (8" MIN. PER SIDE) TYP.

3/16" CONT.

NEW FASCIA CMU

3/4R CONT.

TYP.

1/8 CONT.

VISIBLE STEEL LINTEL SCHEDULE

OPENING SIZE

16" TO 54"

55" TO 90"

6" CMU

(2) L3x3x1/4

(2) L5x3x1/4 LLV

8" CMU

(2) L4x4x1/4

(2) L6x4x5/16 LLV

10" CMU

(2) L5x5x5/16

(2) L5x5x5/16

12" CMU

(2) L6x6x5/16

(2) L6x6x5/16

REQUIRED OPENING LENGTH 16" OR GREATER

BACK TO BACK STEEL

ANGLE LINTEL BEYOND

PER CONCEALED STEEL

LINTEL SCHEDULE

FOR OPENINGS 40" AND

GREATER, ADD NEW #5

VERTICAL REBAR AND GROUT

CELL. SEE B1/S-502 FOR

INSTALLATION DETAIL (TYP. @

EACH SIDE OF OPENING).

MIN.

8"

MIN.

8"

REQUIRED OPENING LENGTH + 16" MIN.

TOOTH IN NEW

FASCIA CMU

SAWCUT CMU

FOR OPENING

REQUIRED OPENING LENGTH 16" OR GREATER

MIN.

8"

MIN.

8"

REQUIRED OPENING LENGTH + 16" MIN.

TOOTH IN NEW

CMU AS

REQUIRED FOR

DAMAGE REPAIR

SAWCUT CMU

FOR OPENING

STEEL ANGLE PER VISIBLE

STEEL LINTEL SCHEDULE

FOR OPENINGS 40" AND

GREATER, ADD NEW #5

VERTICAL REBAR AND GROUT

CELL. SEE B1/S-502 FOR

INSTALLATION DETAIL (TYP. @

EACH SIDE OF OPENING). DRILL

HOLE IN ANGLE LEGS TO

ALLOW BAR TO PASS OR

PROVIDE LINTEL INSTALLATION

PER DETAIL C3/S-501

STEEL ANGLE PER LINTEL SCHEDULE. REMOVE

HORIZ. LEGS OUTSIDE OF NEW OPENING AND

FASTEN VERTICAL LEG TO WALL AS SHOWN

SELECTIVELY SAWCUT

AND REMOVE EXISTING

CMU FOR NEW OPENING.

8" MIN.8" MIN.

NEW OPENING WIDTH

STEEL ANGLE PER

STEEL LINTEL SCHEDULE

EXISTING CMU WALL

STEEL LINTEL SCHEDULE

OPENING SIZE

16" TO 54" (2) L4x4x1/4

8" CMU 12" CMU

(2) L6x6x5/16

3/4R CONT.

TYP.

1/8 CONT.

4'-8" MIN.

3'-4" OPENING

DO NOT SAWCUT/DAMAGE

FILLED CELLS.

HEAD AND SILL STEEL ANGLE PLAN VIEW

1/2"Ø THRU BOLT AT EACH END

OF ANGLES (HEADER AND SILL)5 1/2"5 1/2"

5 1/2"5 1/2"

HEADER SECTION

SEAM WELDED PER

SECTION BELOW

VERT. REBAR AS APPLICABLE

EXISTING CMU WALL

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :4

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-501

B W

M

T Y

P

IC

A L S

T R

U C

T U

R A

L D

E T

A

IL

S

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: NOT TO SCALEA1

TRUSS BEARING PLATE DETAILS

SCALE: NOT TO SCALEB1

CONTROL JOINT DETAIL

SCALE: NOT TO SCALEA2

CMU PENETRATION LINTEL DETAIL

SCALE: 3/4" = 1'-0"C3

ALTERNATE OPENING DETAIL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

SAW CUT A 5"± WIDE VERTICAL STRIP IN EXISTING

CMU AT EACH CELL TO BE REINFORCED. CENTER ON

HOLLOW CORE OF CMU. WIDTH OF CUT MAY REQUIRE

INCREASING, BUT REQUIRES CONTRACTING OFFICER'S

APPROVAL.

REMOVE ALL DEBRIS & LOOSE MATERIAL FROM WITHIN

NEWLY OPENED CORE.

REMOVE ANY EXCESSIVE MORTAR WHICH PROTRUDES

INTO CORE MORE THAN ONE INCH.

DRILL & EPOXY DOWEL BARS 5" MIN. INTO

FOUNDATION AND TOP BEAM AT ROOF UNLESS

DETAILED OTHERWISE. PROVIDE FULL DRILL & EPOXY

THROUGH ALL INTERSECTING LINTELS OR BEAMS.

PLACE VERTICAL REINFORCEMENT IN VOID FROM

FOUNDATION TO ROOF, TIE TO DOWEL BARS NOTED IN

NOTE #4 ABOVE, AND CENTER IN CORE. BARS SHALL

BE OVERLAPPED 18".

PLACE FORM WORK FLUSH AGAINST CUT FACE OF

EXISTING CMU TO ENSURE A FLUSH FINISH.

FILL EXISTING CORE WITH GROUT. PLACE IN 4'-0"

LIFTS & ENSURE AGAINST VOIDS WITHIN EACH POUR.

TOP OF LIFT SHALL BE COORDINATED TO ACCEPT ANY

PLACEMENT OF HORIZONTAL REINFORCEMENT.

UPON COMPLETION OF FILLING CORE & REMOVAL OF

FORM WORK, REPAIR ANY & ALL DEFECTIVE GROUT.

VERTICAL REINFORCEMENT PROCEDURE

1.

2.

3.

4.

5.

6.

7.

8.

5"±

NOTES:

1.

2.

3.

4.

5.

6.

IT SHALL BE ANTICIPATED BY THE CONTRACTOR THAT EXISTING CONDITIONS EXIST WHICH MAY PREVENT REINFORCING PLACEMENT IN

CERTAIN CELLS.

THE CONTRACTOR SHALL PERFORM NON-DESTRUCTIVE TESTING, SUCH AS R-METER TESTING, AS REQUIRED TO LOCATE THOSE CELLS

WHICH ARE HOLLOW & UNOBSTRUCTED, PRIOR TO COMMENCING W/ CUTTING PROCEDURES.

WHERE CELLS ARE FOUND TO BE GROUTED SOLID IN A LOCALIZED AREA WITHIN A CORE THAT IS DESIRABLE FOR THE CONTRACTOR TO PLACE REINFORCING, THE GROUT MAY BE CUT AWAY IN A MANNER THAT INSURES THE ADJACENT GROUT & CMU ARE NOT DISLODGED OR

DAMAGED.

CONTRACTOR SHALL PHASE, SPACE, STAGGER CUT CELLS AROUND BUILDING, REINFORCE & POUR, AS REQUIRED TO PROTECT THE

STABILITY & INTEGRITY OF THE STRUCTURE.

AT CONTRACTOR'S OPTION, SAW CUTTING OF EXISTING CMU MAY BE OMITTED IF THE BAR CAN BE INSTALLED BY FEEDING IT DOWN A WALL SECTION NOT EXCEEDING 4' IN HEIGHT. THE CORE OF THE CMU UNIT RECEIVING THE REINFORCEMENT SHALL BE PREPARED & CLEANED OF MORTAR AND OTHER DEBRIS/OBJECTS WHICH OBSTRUCTS OR HINDERS PLACEMENT OF BAR AND CONCRETE.

WHERE NEW CMU IS PROVIDED, IT SHALL BE REINFORCED WITH MATERIALS SIMILAR TO THOSE CALLED FOR IN THE PROCEDURE

OUTLINED FOR EXISTING CMU, UNLESS NOTED OTHERWISE ON DRAWINGS.

36/4 PATTERN W/ #12 TEK SCREWS

INTO SUPPORT MEMBERS

SECTION VIEW

EDGE

SUPPORT

MEMBER

SUPPORT

MEMBER

BELOW

1.5B22

STEEL

DECK

SIDELAP

CONNECTION

W/ (2) #10

TEK SCREWS

SUPPORT

MEMBER

GENERAL NOTES:

1. ROOF DECK SHALL BE GALVANIZED

AND CMC JOIST AND DECK 1.5B22

DECKING OR EQUAL. ROOF DECK

SHALL BE CONTINUOUS OVER 3 OR

MORE SPANS.

2. ATTACH DECK TO SUPPORT MEMBER

AS SHOWN ON DETAIL USING 36/4

PATTERN W/ #12 TEK SCREWS IN

SUPPORT FASTENERS & #10 TEK

SCREWS FOR SIDELAP.

3. DESIGN LOADS AS SPECIFIED ON THE

STRUCTURAL GENERAL NOTES

SHEETS S-001 & S-002.

4. FIELD VERIFY ALL DIMENSIONS PRIOR

TO FABRICATION.

PLAN VIEW

36" PANEL WIDTH 36" PANEL WIDTH

8" CMU WALL W/ #5 @ 32" O.C.

VERTICAL. FILL CELLS W/

GROUT. HORIZ. W1.7 LADDER

REINF. @ 16" O.C.

REINFORCE 3 CELLS AT CORNER W/ #5

VERTICAL. FILL CELLS W/ GROUT

PRE-FABRICATED CORNER WIRE REINFORCING

8" CMU WALL W/ #5 @ 32"

O.C. VERTICAL. FILL CELLS

W/ GROUT. HORIZ. W1.7

LADDER REINF. @ 16" O.C.

REINFORCE 3 CELLS AT

CORNER W/ #5 VERTICAL.

FILL CELLS W/ GROUT

PRE-FABRICATED INTERSECTION

WIRE REINFORCING

REINFORCE LAST 2 CELLS OF

CMU AT DOOR OR WINDOW

OPENINGS. FILL CELLS W/ GROUT

1. TYPICAL VERTICAL CMU REINFORCEMENT SHALL BE #5 @ 32" O.C. UNLESS

NOTED OTHERWISE.

2. ALL CELLS BELOW GRADE SHALL BE FULLY GROUTED.

NOTES:

8" CMU WALL W/ #5 @ 32" O.C.

VERTICAL. FILL CELLS W/

GROUT. HORIZ. W1.7 LADDER

REINF. @ 16" O.C.

No. 29581

S

OU

TH

CAROL IN

A

B

R A D L E Y W. M I N

O

R

L I C E N S E D P

RO

FESS I ONA L

E N G I N E E R

SHEET

IDENTIFICATION

1 2 3 4 5

D R

A W

N B

Y

D E

S

IG

N B

Y

S B

M T

B Y

S

IZ

E

F

IL

E N

A M

E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N A

V A

L A

IR

S

T A

T

IO

N

C K

D B

Y x

D

C

B

A

F

IL

E N

U M

B E

R

P L

O T

S C

A L E

P L

O T

D A

T E

SHEET OF

-C

M id la n d P k w y

S u m m e rv ill e

S o u th C a ro lin a

.8

.3

E N

G

IN

E E

R

IN

G

A R

C H

I T E

C T

U R

E C

E M

S P ro je c t N o

S

P ro je c t M a n a g e r:

B ra d M in o r

A S

S H

O W

N

J O

IN

T

R E

S E

R V

E B

A S

E F

O R

T W

O R

T H

T

X

/1

/2

:1 :4

P

M

M A

IN

T

E N

A N

C E

S Q

U A

D R

O N

B L D

G

D D

P M

/1 /2

D

F A

-1

-D

-0

B W

M

J L

B W

M

S-502

B W

M

T Y

P

IC

A L S

T R

U C

T U

R A

L D

E T

A

IL

S

A D

D

IT

IO

N

/ R E

N O

V A

T

IO

N

S

T

04/12/2016

SCALE: NOT TO SCALEB1

VERTICAL REINFORCEMENT PROCEDURE

SCALE: 3/4" = 1'-0"C3

METAL DECK FASTENING DETAIL

SCALE: 3/4" = 1'-0"A3

TYPICAL CMU REINFORCEMENT

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P

1. ALL EXISTING CONDITIONS AND DIMENSIONS SPECIFIED PER ORIGINAL DESIGN DRAWINGS AND NON- DESTRUCTIVE SITE INVESTIGATIONS. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF DEMOLITION/CONSTRUCTION (TYP.) AND NOTIFY GOVERNMENT PROMPTLY IF ANY DISCREPANCIES

EXIST.

2. REMOVE ALL EXISTING WORK/MATERIAL, AS DESIGNATED, IN THEIR ENTIRETY DOWN TO ORIGINAL SUBSTRATES IN INDICATED AREAS TO PERMIT COMPLETION OF ALL REPAIRS AND REPLACEMENTS.

3. REMOVE ABANDONED PENETRATIONS.

4. EXISTING SOUND NAILERS AND BLOCKING NOT OTHERWISE INDICATED TO BE REPLACED MAY REMAIN. UNIT

PRICE QUANTITIES SHALL BE USED FOR ANY EXISTING WOOD TO BE REPLACED.

5. WHERE DEMOLITION AND NEW WORK OCCURS LEAD PAINT SHALL BE REMOVED PER STATE REGULATIONS BY

APPROVED AND CERTIFIED ENTITIES REFER TO LEAD AND ASBESTOS REPORT.

GENERAL DEMOLITION NOTES:

1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF THE WORK. THE DRAWINGS ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, ON THE BASIS OF THE GENERAL PERFORMANCE CRITERIA

AND GENERAL EXTENT OF WORK INDICATED, DESCRIBED OR REQUIRED.

2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT DOCUMENTS SHALL

NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR IMPLIED THEREFROM.

3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE WORK SO THAT NO WORK

SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.

4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO

THE CONTRACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING WITH THE WORK.

5. THE CONTRACTOR SHALL PROTECT EXISTING, IN-PLACE, AND NEW WORK.

6. ALL WORK NOTED "N.I.C." OR "G.F.G.I." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF WORK

AGREEMENT.

7. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL NEW AND EXISTING CONDITIONS, SHOWN ON THESE DRAWINGS, AT THE SITE. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK. COMMENCEMENT OF WORK

SHALL CONSTITUTE ACCEPTANCE OF ALL NEW OR EXISTING CONDITIONS.

8. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER IN WRITING OF ANY DIFFERING

CONDITIONS BEFORE COMMENCEMENT OF WORK.

9. UNLESS NOTED OTHERWISE, ALL NEW GYPSUM BOARD SURFACES ARE TO RECEIVE ONE PRIMER COAT AND

TWO COATS OF PAINT.

10.DIMENSIONS NOTED AS 'HOLD' SHALL NOT VARY BY MORE THAN 1/8" FROM SIDE TO SIDE OR FROM FRONT TO

BACK, FINISHED SURFACE TO FINISHED SURFACE.

11.NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION OPERATIONS SHALL BE

APPLIED.

12.WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING SHALL BE

CONSTRUCTED AS DETAILED OR REFERENCED BY UL OR OTHER REFERENCE.

13.DIMENSIONS SHOWN ARE TO FINISH FACE OF WALL UNLESS SPECIFICALLY NOTED OTHERWISE.

14.PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER PRODUCT MANUFACTURER'S STANDARDS.

15.THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES

AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY BUILDING AND FIRE PERMITS FROM ALL

AUTHORITIES HAVING JURISDICTION.

16.ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF ALL APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES.

17.ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC CORROSION.

18.NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS ARE TO BE

REVIEWED AND NOTES ON ANY ONE SHEET ARE TO BE APPLIED TO RELATED DRAWINGS AND DETAILS.

19.A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL IS TO BE FINISHED OR

FIRE-RATED AS INDICATED.

20.WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR OPENINGS, THE DOOR WIDTH AND

THE DOOR FRAME DETAILS DETERMINE THE LOCATION OF ADJACENT WALLS AND FRAMES.

21.DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT THE CONTRACTING OFFICER BEFORE

PROCEEDING WITH THE WORK.

22.THE CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL FLOOR AND WALL SLEEVES, CONDUIT AND ALL MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, STRUCTURAL AND

ARCHITECTURAL ITEMS.

23.PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED FOR MECHANICAL EQUIPMENT AND PLUMBING WORK. ALL ACCESS PANEL LOCATIONS SHALL BE REVIEWED WITH THE

CONTRACTING OFFICER PRIOR TO PROCEEDING.

24.ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS, FIRE RATING, AND STRUCTURAL INTEGRITY

OF THE BUILDING.

25.CONTRACTOR SHALL PLAN THEIR WORK TO PROVIDE ADEQUATE PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO PERSONS AND

PROPERTY AS NECESSARY.

26.CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED IN OR ABOUT EXISTING

FACILITIES WITH CONTRACTING OFFICER, PRIOR TO START OF SUCH WORK.

27.INTERIOR PARTITION AND CEILING MOVEMENT CONTROL:

A. VERTICAL CONTROL JOINTS FOR ANY GWB WALL LENGTH ARE TO OCCUR AT NOT MORE THAN 30'-0" O.C.

(900 SQ. FT. MAX) IN THE…