Bldg__346_First_Floor.pdf

PDF 166 KB Posted

Attached to
Premise Wiring for Building 346
Solicitation number
FA6648-15-T-0003
Issued by

About this file

Bldg 346 First Floor

View the file

Other files

File Type Posted
Copy_of_CAT6_Cable_Color_Code.xlsx XLSX spreadsheet
CAT_6_Cabling.pdf PDF
Example_of_Patch_Panel_layout.docx DOCX document
TIA-EIA-569-A-7-Cable_Tray.pdf PDF
Bldg__346_Second_Floor.pdf PDF
B346_OSP_CVC_snap_shot.docx DOCX document
List_of_Materials_for_the_review.pdf PDF
Existing_handholes_and_manholes_to_bldg_346.pdf PDF
B346_Project_Illustrated_Photos.docx DOCX document
Education__Training_Comm_Layout.jpg JPG image
Q__A_Bldg__346_docx_(2).docx DOCX document
Example_of_Patch_Panel_layout.docx DOCX document
Copy_of_CAT6_Cable_Color_Code.xlsx XLSX spreadsheet
TIA-EIA-569-A-7-Cable_Tray.pdf PDF
CAT_6_Cabling.pdf PDF
List_of_Materials_for_the_review.pdf PDF
Q__A_Bldg__346_docx_(2).docx DOCX document
B346_OSP_CVC_snap_shot.docx DOCX document
Existing_handholes_and_manholes_to_bldg_346.pdf PDF
B346_Project_Illustrated_Photos.docx DOCX document
Bldg__346_Second_Floor.pdf PDF
SOW_Premise_Wiring_B346.doc DOC document
Education__Training_Comm_Layout.jpg JPG image
Bldg__346_First_Floor.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3750G10.40.21.146

Building 346 First Floor

Building 346 – Total Drops 179

DEERS RM 1101: 30 Data Drops

PASS & ID REGISTRATION RM 1100.1: 8 Data Drops

PASS & ID REGISTRATION RM 1100.2: 8 Data Drops

PASS & ID WAITING AREA RM 1100: 12 Data Drops

DEFENSE FUELS RM 1102: 32 Data Drops

DEFENSE FUELS RM 1102.1: 8 Data Drops

MASK FIT TESTING RM 1105: 12 Data Drops

RECRUITING RM 1106.2: 12 Data Drops

RECRUITING RM 1106.3: 0 Data Drops

RECRUITING RM 1106: 16 Data Drops

RECRUITING RM 1106.1: 12 Data Drops

RECRUITING RM 1108: 16 Data Drops

RECRUITING RM 1107: 8 Data Drops

HALL RM 1110: 2 Data Drops

Total: 176

Single Gang 4 Port Face Plates w/Station ID Category 6 Plenum UTP Data Cables

Single Gang 2 Port Face Plates w/Station ID Category 6 Plenum UTP Data Cables

One single CAT 6 drop in the false ceiling for wireless Access Point (AP) node

New conduit from Mech. Rm (1 st Floor) to Comm. Rm (2 nd Floor)

New Cable Tray

Two 4 inch conduits from Mech Rm to

Comm Rm (outside)

Two 4 inch conduits from Mech Rm ceiling to Comm Rm (inside)