Bldg__346_First_Floor.pdf

PDF 166 KB Posted

Attached to
Premise Wiring for Building 346 Federal contract opportunity
Solicitation number
FA6648-15-T-0003
Issued by
Department of the Air Force Reserve Command

About this file

Floor Plan 1st Floor

View the file

Other files for this federal contract opportunity

Other files attached to Premise Wiring for Building 346, newest first.
File Type Posted
CAT_6_Cabling.pdf PDF
B346_OSP_CVC_snap_shot.docx DOCX document
List_of_Materials_for_the_review.pdf PDF
Education__Training_Comm_Layout.jpg JPG image
B346_Project_Illustrated_Photos.docx DOCX document
Bldg__346_First_Floor.pdf PDF
Q__A_Bldg__346_docx_(2).docx DOCX document
Copy_of_CAT6_Cable_Color_Code.xlsx XLSX spreadsheet
Example_of_Patch_Panel_layout.docx DOCX document
Bldg__346_Second_Floor.pdf PDF
TIA-EIA-569-A-7-Cable_Tray.pdf PDF
Existing_handholes_and_manholes_to_bldg_346.pdf PDF
CAT_6_Cabling.pdf PDF
List_of_Materials_for_the_review.pdf PDF
B346_OSP_CVC_snap_shot.docx DOCX document
Q__A_Bldg__346_docx_(2).docx DOCX document
Example_of_Patch_Panel_layout.docx DOCX document
Copy_of_CAT6_Cable_Color_Code.xlsx XLSX spreadsheet
TIA-EIA-569-A-7-Cable_Tray.pdf PDF
Existing_handholes_and_manholes_to_bldg_346.pdf PDF
SOW_Premise_Wiring_B346.doc DOC document
Education__Training_Comm_Layout.jpg JPG image
B346_Project_Illustrated_Photos.docx DOCX document
Bldg__346_Second_Floor.pdf PDF
Show all 24

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3750G10.40.21.146

Building 346 First Floor

Building 346 – Total Drops 179

DEERS RM 1101: 30 Data Drops

PASS & ID REGISTRATION RM 1100.1: 8 Data Drops

PASS & ID REGISTRATION RM 1100.2: 8 Data Drops

PASS & ID WAITING AREA RM 1100: 12 Data Drops

DEFENSE FUELS RM 1102: 32 Data Drops

DEFENSE FUELS RM 1102.1: 8 Data Drops

MASK FIT TESTING RM 1105: 12 Data Drops

RECRUITING RM 1106.2: 12 Data Drops

RECRUITING RM 1106.3: 0 Data Drops

RECRUITING RM 1106: 16 Data Drops

RECRUITING RM 1106.1: 12 Data Drops

RECRUITING RM 1108: 16 Data Drops

RECRUITING RM 1107: 8 Data Drops

HALL RM 1110: 2 Data Drops

Total: 176

Single Gang 4 Port Face Plates w/Station ID Category 6 Plenum UTP Data Cables

Single Gang 2 Port Face Plates w/Station ID Category 6 Plenum UTP Data Cables

One single CAT 6 drop in the false ceiling for wireless Access Point (AP) node

New conduit from Mech. Rm (1 st Floor) to Comm. Rm (2 nd Floor)

New Cable Tray

Two 4 inch conduits from Mech Rm to

Comm Rm (outside)

Two 4 inch conduits from Mech Rm ceiling to Comm Rm (inside)

Bldg. 346 First Floor.vsd