This document contains a submittal register and solicitation details for a federal contract opportunity to repair roofs at Hangar 1 and 3 at Westover Air Reserve Base. The submittal register outlines required submissions from the contractor, including drawings, specifications, daily reports, inspection reports, warranties, and closeout documents. It also lists the relevant sections of the specifications for each submission. The solicitation will be issued in July 2020 as a firm fixed price contract for roof repairs and a new permanent fall protection system. The work includes seam repair of an existing TPO roof membrane and design and installation of anchoring points for the fall protection system. The estimated value is between $500,000 and $1 million. The solicitation will be a total small business set-aside under NAICS code 238160. Interested parties must register in the SAM database and check the website for amendments. Award is contingent upon available funds, and the government may cancel the solicitation before or after closing.

View the file

Other files for this federal contract opportunity

Show all 18

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

SUBMITTAL REGISTERCONTRACT NO
YTPM 18-0006
TITLE AND LOCATIONCONTRACTOR
REPAIR BARELL ROOF H1CONTRACTOR SCHEDULES DATESCONTRATOR ACTIONAPPROVING AUTHORITY
ACTIVITY NOTRANSMITTAL NORefence sectionDESCRIPTION ITEM SUBMITTEDP A R A G R A P H #CLASSIFICATION GOVT OR A/E REVIERSUBMITAPPROVAL NEEDED BYMATERIAL NEEDED BYACTION CODEDATE OF ACTIONDATE FWD AUTH/ DATE RCD FROM CNTRDATE FWD TO OTHER REVIEWERDATE FWD FROM OTHER REVIEWERACTION CODEDATE OF ACTIONMAILED TO CONTR/ DATE RCD FRM APR AUTHREMARKS
(a)(b)c(d)"(e)"(f)(g)(h)(i)(j)(k)(l)(m)(n)(o)(p)(q)
SOW
Prime Contractor Experience Information, Key Players2.7.1.1G
Installer Qualifications2.7.1.2G
RRC Information2.7.1.3G
RRO Qualifications2.7.1.4G
Licensed Structural Engineer Info2.7.1.5G
Field Investigation Report3.30G
Drawings (TPO Repair)3.4.2G
As-built Drawings (TPO)3.4.3G
Specifications (TPO)3.5.1G
Plan analysis (FP)3.6.1.1G
Drawings (FP)3.6.1.2G
Specifications (FP)3.6.1.4G
Catalog Cuts (FP)3.6.1.5G
Contractor Review and Approval by PE3.6.1.6G
Project Disks3.6.1.7G
Register Roof Observer (RRO) Daily Reports4.2.4.1G
Register Roof Observer (RRO) Photographs4.2.4.2G
Roof Signs4.3.1G
Pre-final InspectionG
TPO Membrane Pre-Final Inspection Report6.3.1G
Final Inspection7.10G
Certificate of inspection by Permanent Fall Protection Manufacturer7.2.1G
Close-Out Submittals7.3.1G
Warranty (FP)12.30G
General Conditions
Badge Requests (439 AW Form 1)1.2.BG
Dig Safe (if required)1.30G
Notification Prior to Construction or Demolition (BWP AQ 06)1.80G
Scheduling1.10G
Hazardous Material Reporting (439 AW Form 20)1.15G
Construction/Demolition Waste Management Plan and Reporting1.19G
C/D/W Report1.19G
Daily Report1.21G
Specifications Attachment B
SD-02 Shop Drawings1.5.2G
SD-03 Product Data1.5.2G
SD-04 Samples1.5.2G
SD-06 Test Reports1.5.2G
SD-07 Certificates1.5.2G
SD-08 MFR's Instructions1.5.2G
SD-09 MFR's Field Report1.5.2G
SD-10 O&M Data1.5.2G
SD-11 Closeout Documents1.5.2G