This is a Bill of Materials (BOM) attachment listing all equipment, materials, labor services, and ancillary costs required for the Engineering, Furnishing, Installation, and Testing (EFI&T) of a fiber optic transmission system (FOTS) to replace discontinued Time Division Multiplexing (TDM) channel banks at Aviano Air Base, Italy, under solicitation FA568226QA050. The materials are organized by location (Glideslope, Localizer, TACAN, RAPCON, GATR, Tower, and Alt Tower) and include TCCOM brand network equipment such as RS-232 modules, 1U and 4U chassis, multiplexer FXS/FXO modules, power adapters, APC UPS systems (ranging from 1kVA to 2kVA), JumboSwitch 10G/1G rack-mount card cages, Ethernet management cards, SFP transceivers, and TCView monitoring hardware. The BOM specifies manufacturer part numbers, estimated quantities, unit costs (not populated in this revision), and total cost columns for each item, along with miscellaneous installation parts and a TC Care Service hardware maintenance contract for the GATR location.

Labor services are quantified separately and include Project Manager Services (32 hours), Telecommunications Engineer Services (80 hours), Technical Writer Services (24 hours), and Install Labor (480 hours), with unit costs and total costs to be determined. Additional line items cover per diem, travel, rental fees, vendor service fees, and shipping costs on a per-lot basis. This is Revision 1 of the materials list, updated following Amendment 3 to address discrepancies in the SOO and previous bill of materials versions, with the final solicitation deadline established as 16 July 2026 under a firm fixed price (FFP) contracting approach.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1

LIST OF MATERIALS AND SERVICES REQUIRED
ManufacturerManufacturer Part #Estimated QtyDescriptionUnit Cost
EstimateTotalLocation
TCCOMTC8802R-0000-5A-121RS-232 ModuleGlideslope
TCCOMTCRM195R-S-0121U Box ChassisGlideslope
TCCOMTC8800R-L1SC-04-121Tele Mux FXS ModuleGlideslope
TCCOMTC3PS-TB-25-012Power Adapter for 115VACGlideslope
APCSMC1000C11kVA UPS (APC or Equivalent)Glideslope
TCCOMTC8802R-0000-5A-121RS-232 ModuleLocalizer
TCCOMTCRM195R-S-0121U Box ChassisLocalizer
TCCOMTC8800R-L1SC-04-121Tele Mux FXS ModuleLocalizer
TCCOMTC3PS-TB-25-012Power Adapter for 115VACLocalizer
APCSMC1000C11kVA UPS (APC or Equivalent)Localizer
TCCOMTC8802R-0000-5A-121RS-232 ModuleTACAN
TCCOMTCRM195R-S-0121U Box ChassisTACAN
TCCOMTC8800R-L1SC-04-121Tele Mux FXS ModuleTACAN
TCCOMTC3PS-TB-25-012Power Adapter for 115VACTACAN
APCSMC1000C11kVA UPS (APC or Equivalent)TACAN
TCCOMTCRM191R-01-01 PP14U 19in Mux Card Cage for RackMount Card (-10C to 50C), Dual Power Cards, 115/240V
AC, Power Back PlaneRAPCON
TCCOMTC8801R-L1SC04-123Tele Mux FXO ModuleRAPCON
TCCOMTC8802R-0000-5A-123RS-232 ModuleRAPCON
APCSMC2000I-2U12kVA UPS (APC or Equivalent)RAPCON
TCCOMN/A1Miscellaneous Installation Parts - ILS Transport SitesN/A
TCCOMTRCM19BR1JumboSwitch 10G/1G 4U 19in Rack-mount Card Cage, High Temp (-20C to 70C), Power A
115/240VAC, Power B 115/240VACGATR
TCCOMTC3840R-512-ports 10/100/1000M and 2-ports SFP Ethernet management cardGATR
TCCOMTC3846R-664-channel 4-wire 600ohm analog and Bi-directional Dry contact over IP cardGATR
CiscoSM 1G SFP2SFPGATR
APCSMC2000I-2U12kVA UPS (APC or Equivalent)GATR
TCCOMTRCM19BR1JumboSwitch 10G/1G 4U 19in Rack-mount Card Cage, High Temp (-20C to 70C), Power A
115/240VAC, Power B 115/240VACTower
TCCOMTC3840R-512-ports 10/100/1000M and 2-ports SFP Ethernet management cardTower
TCCOMTC3846R-644-channel 4-wire 600ohm analog and Bi-directional Dry contact over IP cardTower
CiscoSM 1G SFP2SFPTower
APCSMC2000I-2U12kVA UPS (APC or Equivalent)Tower
TCCOMTRCM19BR1JumboSwitch 10G/1G 4U 19in Rack-mount Card Cage, High Temp (-20C to 70C), Power A
115/240VAC, Power B 115/240VACRAPCON
TCCOMTC3840R-512-ports 10/100/1000M and 2-ports SFP Ethernet management cardRAPCON
TCCOMTC3846R-654-channel 4-wire 600ohm analog and Bi-directional Dry contact over IP cardRAPCON
CiscoSM 1G SFP2SFPRAPCON
APCSMC2000I-2U12kVA UPS (APC or Equivalent)RAPCON
TCCOMTRCM19BR1JumboSwitch 10G/1G 4U 19in Rack-mount Card Cage, High Temp (-20C to 70C), Power A
115/240VAC, Power B 115/240VACAlt Tower
TCCOMTC3840R-512-ports 10/100/1000M and 2-ports SFP Ethernet management cardAlt Tower
TCCOMTC3846R-634-channel 4-wire 600ohm analog and Bi-directional Dry contact over IP cardAlt Tower
CiscoSM 1G SFP2SFPAlt Tower
APCSMC2000I-2U12kVA UPS (APC or Equivalent)Alt Tower
TCCOMN/A1Miscellaneous Installation Parts - Radio Transport SitesN/A
TCCOMTCVIEW-A3CA02011TCView HW & SW for monitoring all modulesGATR
TCCOMSCS-TCCCA-HA-L311TC Care Service TC Hardware
N/AN/A32Project Manager Services (per hour)N/A
N/AN/A80Telecommunications Engineer Services (per hour)N/A
N/AN/A24Technical Writer Services (per hour)N/A
N/AN/A480Install Labor (per hour)N/A
N/AN/A1Per diem/Travel/Rental Fees (per Lot)N/A
N/AN/A1Vendor Service Fee (per Lot)N/A
N/AN/A1ShippingN/A

Total Cost

File details come from the government source that posted it. Updated .