UUUY_17-1043_Technical_Specifications.pdf
PDF 334 KB Posted
- Solicitation number
- FA568217R0035
About this file
UUUY 17-1043 TECHNICAL SPECIFICATIONS
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Project: UUUY 17-1043 Technical Specifications
DATE: APRIL 2017
31CES/CENMP 1
Date: APRIL 2017
U.S. AIR FORCE
31ST FIGHTER WING
31ST CES/CENMP
AVIANO AIR BASE, ITALY
TECHNICAL SPECIFICATIONS FOR
UUUY 17-1043
SUSTAIN EXTERIOR WALLS AND ROOFS, MULTI,
SAN VITO DEI NORMANNI,
BRINDISI, ITALY
31CES/CENMP 2
1. SCOPE OF WORK. The Contractor shall provide all management, tools, supplies, equipment, transportation and qualified personnel necessary to paint exterior of all seven facilities in SEON complex, repair roofs on Bldgs. 30801, 30901,30802, 309, 44203, 81244 and replace metal doors on Bldgs. 308, 30801, 30802, 309, 81244.
Contractor shall comply with vigent regulations and law in force. Contractor shall store their materials in designated areas as specified by the Project Manager or Representative.
2. WORK LOCATION. Work place performance will be San Vito dei Normanni, Brindisi, Italy.
31CES/CENMP 3
3. WORK SITE CONDITIONS
a. Works shall be performed in three (3) phases. Contractor may be allowed to work at three building at the time. Contractor will submit a work schedule to Project Manager for approval before start any activity on site.
b. The Contractor shall provide electricity on work site, if needed, with its own power generator at no additional cost for the Government. Water will be available but Contractor shall provide a temporary above ground line if needed. The Contractor shall not alter characteristics and shall observe conservation practices at all times. All connections shall be the responsibility of the Contractor including restorations to initial conditions.
c. Authorized work hours and days. Performance of work hereunder shall be from Monday through Friday excluding holidays from 08.00 to 17.00 hours. Work during weekends or holidays may be requested by the Contractor with a minimum of 10 days advance notice, however the Contracting Officer has the right to deny such request if reasons requiring weekend and holiday work are not valid or for security or other necessities.
d. Toilet facilities in the vicinity of the work site shall not be available for Contractor use. It will be contractor responsibility to provide temporary porta-potty at no additional cost for the Government.
e. The Contractor shall not use base refuse containers to discard debris. All construction debris shall be discarded by the Contractor off base at authorized sites according to category of debris/refuse in strict observance of all host country laws, decrees and local regulations in force.
f. The Contractor shall be responsible for ensuring all personnel engaged in the performance of this contract observe all host country laws concerning safety. At all times the Contractor will assure all personnel are wearing the correct safety equipment when performing their work, such as steel toe boots, gloves, reflective gear and any other equipment deemed necessary to perform their work in the safest form. The Contractor shall also assure all personnel comply with Italian laws DM. 81/08.
g. Interruption of utilities. Utilities shall not be interrupted until approval is received from the Contracting Officer. Any such need shall be requested in writing by the Contractor at least 15 days in advance of the needed interruption. Requests for utility interruption shall indicate the type of utility to be interrupted, the type of operation requiring the interruption, the date and duration. To the maximum extent possible interruption shall be scheduled on weekends or U.S. holidays in order to minimize impact to base activities.
h. If welding is to be performed the Contractor shall ensure a welding permit is obtained from the Aviano Air Base Fire Department prior to performing welding operations.
31CES/CENMP 4
4. GENERAL NOTES
1. At the end of the work, the Contractor shall provide the Government with three copies of the following documents: for warranty call purpose, 3 copies of letter identifying project number, item, company address, phone number, point of contact, item warranty expiration date, etc.
2. Once issued NTP, Contractor is required to contact CEAOR (Ms. Cristina Rossetto 0434-305691) and schedule a meeting to fill Form DD1354 with appropriate project data for real property capitalization (DD1354 and category codes list CATCODE_LIST_2010 are available in engineering office during normal hours of operation). Contractor is required to provide final Form DD1354 for 31CES/CD signature before contract close out.
3. The Contractor shall return all areas disturbed during construction to their original condition before final acceptance by the Government.
4. Housekeeping and Site Clean-up: At the end of each working day, the Contractor shall be responsible for cleaning of the area. Such functions include disposal of accumulated waste materials and rubbish and other operations necessary to present a neat appearance at all times. Contractors shall ensure all light weight debris at the construction site is properly secured in waste receptacles so that it does not blow away to another area.
31CES/CENMP 5
5. WORK DESCRIPTION
Each item of the schedule is inclusive of furnishing and installation of materials and equipment, scaffolding, transportation to dump or storage of demolished and/or removed materials, in accordance with contracting officer's instructions and all finishing work required to make each item complete in a workmanlike manner.
All the quantities that are indicated or successively added are estimates. Therefore the government shall be not held responsible for the accuracy of the estimated quantities. The contract requires a completed project on a lump sum basis. It is therefore the responsibility of the contractor to calculate, foresee and perform all quantities and work necessary even if not mentioned in the specifications but included in the drawings and/or are manifested, in order to deliver a complete project based on its overall scope.
Building 308 :
5.1.a Paint application for all exterior metal surfaces, including roof, louvers, downspouts (five) and gutters. Contractor shall apply one coat of universal rust proof paint on rusted areas type Duli or equivalent and two coats of solvent synthetic enamel paint based on alkylate resins (“smalto alchidico”) type Caparol “Capalac Buntlack” or equivalent. Contractor shall remove all harmful substances from all metal surfaces using a jet blasting method, sandpaper, wire brush or sub with steel wool over the entire surface and scrape where necessary to remove damaged paint. Contractor shall clean all rusted spots down to bare metal including spots where rust discoloration appears through the existing coating and apply one extra coat of anticorrosive paint. Contractor shall use the proper equipment to perform the job, including scaffolding, protections, removing and re-installation of existing lighgting protection system, cleaning and any other work to provide a job performed in a work-manlike manner.
416.00 SQ.M.
5.1.b Furnish and installation of multipurpose steel doors, brand “NINZ PROGET” or equivalent, 6 cm thickness, “Sendzimir” processed hot-galvanized sheet metal, press folded and electro-welded, heat insulated treated mineral wool packing rigidly joined to the sheet metal, equipped with panic bars at three point locking mechanism, stainless steel handle, stainless steel kicks plates on both sides, sealing, gaskets, cylinders, doors closer, including special frames extension for proget doors. Item includes removal, transportation and disposal of existing doors and frames to public dump, dumping fees and any other work to provide a job performed in a workmanlike manner.
I) one wing door with dimensions 90x215 cm equipped with multipurpose rectangular window 400x600 mm, metal window frame and push bar;
2 Each II) double wing door with dimension 180x215 cm.
1 Each
31CES/CENMP 6
Building 30801 :
5.2.a Removal of existing double layer waterproofing materials on the flat roof, cleaning, including existing metal flashing. Item includes cleaning, scaffolding, loading and transportation of resulting materials to authorized dump, dumping fees and any other work to provide a job performed in a
78.50 SQ.M.
5.2.b Furnish and installation on new roof package consisting:
- Solvent-based primer type Index Indever or similar approved. Bituminous solution containing and quick-drying solvents.
- First layer Elastoplastomeric polymer-bitumen waterproofing membrane type Index Flexter Flex Testudo Spunbond Poliestere or similar approved, 4 mm thick, reinforced with composed “non woven fabric” single –strand Spunbond polyester, flexibility to low temperature -25 C, stabilized with rot-proof fiber-glass and certified with ITC Agreement.
- Final layer elastoplastomeric polymer-bitumen waterproofing membrane type Index Mineral Reflex White Flexter Testudo FR TRIARM or similar approved, 4 mm thick, reinforced elastoplastomeric polymer-distilled bitumen membrane, with a distilled bitumen, plastomer and elastomer base, 3-layer composite stabilized Spunbond polyester reinforcement, flexibility to low temperature -15 C, special high saturation and luminosity white mineral self-protection for energy saving and the reduction of “urban heat islands” having Solar Reflectance Index SRI > 52- 54.
- Item includes exhaust vents n. 1/30 Sq.m. and any other items to provide a job performed in a workmanlike manner.
78.50 SQ.M
5.2.c Furnish and installation of new hot galvanized factory painted metal flashing, thickness 8/10, development 45 cm, color dark brown. Item includes scaffolding and any other work to provide a job performed in a work-manlike manner.
46.20 L.M.
5.2.d Paint exterior walls surfaces consisting of: water jet blasting, surface preparation, special smoothing plaster (rasante) for damaged surfaces, application of one coat of solvent primer type Sigmafix white or equivalent and two coats of acrylic anti carbonate paint type SIGMAFACADE TOPCOAT or equivalent, particularly suitable for the protection of façade and reinforced concrete walls. Surfaces to be treated must be fully cured, clean and dry, free from dust and part with poor adherence, including scaffolding and any other work to provide a job performed in a work-manlike manner.
150.20 SQ.M.
5.2.e Supply and installation of new external anodized aluminum doors, double wing with louvers, having dimensions 170x220 cm, including Cisa lock (Best Lock compatible), stainless steel handle, door closer, insect screen, color dark brown and accessories. Item includes removal of existing metal doors and frames, loading and transportation of resulting material to authorized dump, dumping fees and any other work to provide a job performed in a work-manlike manner.
2 Each
31CES/CENMP 7
Building 30901 :
5.3.a Removal of existing double layer waterproofing materials on the flat roof, cleaning, including existing metal flashing. Item includes cleaning, scaffolding, loading and transportation of resulting materials to authorized dump, dumping fees and any other work to provide a job performed in a
5.20 SQ.M.
5.3.b Furnish and installation on new roof package consisting:
quick-drying solvents.
- First layer Elastoplastomeric polymer-bitumen waterproofing membrane type Index Flexter Flex Testudo Spunbond Poliestere or similar approved, 4 mm thick, reinforced with composed “non woven fabric” single –strand Spunbond polyester, flexibility to low temperature -25 C, stabilized with rot-proof fiber-glass and certified with ITC Agreement.
- Final layer elastoplastomeric polymer-bitumen waterproofing membrane type Index Mineral Reflex White Flexter Testudo FR TRIARM or similar approved, 4 mm thick, reinforced elastoplastomeric polymer-distilled bitumen membrane, with a distilled bitumen, plastomer and elastomer base, 3-layer composite stabilized Spunbond polyester reinforcement, flexibility to low temperature -15 C, special high saturation and luminosity white mineral self-protection for energy saving and the reduction of “urban heat islands” having Solar Reflectance Index SRI > 52- 54.
- Item includes one exhaust vent and any other items to provide a job performed in a workmanlike manner.
5.20 SQ.M
5.3.c Furnish and installation of new hot galvanized factory painted metal flashing, thickness 8/10, development 45 cm, color dark brown. Item includes scaffolding and any other work to provide a job
9.16 L.M.
5.3.d Paint exterior walls surfaces consisting of: water jet blasting, surface preparation as necessary including removal of plaster that sounds hollow prior to start any painting activities. Item foreseen the furnishing and application of two coats of mineral fiber-reinforced smoothing (“rasatura armata”), specific for restoration, thickness 6 mm, type Rofix Renoplus or equivalent, plaster repair where necessary using the same Rofix product. Item includes application of siloxane primer “ PP 301 HYDRO LF” or equivalent and installation of 150 gr/SqM alkali- resistant fiberglass mesh “P- 50”. Furnish and installation of protective high thickness finishing layer, type Rofix “Protec ai silossani”, grain size 1.5 mm, or equivalent, including application of one coat of fixative “Primer Premium” and any other work to provide a job performed in a work-manlike manner. Installation of above described products will be strictly performed according to manufacturer installation instructions.
25.00 SQ.M.
31CES/CENMP 8
Building 30802 :
5.4.a Removal of existing double layer waterproofing materials on the flat roof and cleaning. Item includes cleaning, scaffolding, loading and transportation of resulting materials to authorized dump, dumping fees and any other work to provide a job performed in a work-manlike manner.
52.00 SQ.M.
5.4.b Furnish and installation on new roof package consisting:
quick-drying solvents.
- First layer Elastoplastomeric polymer-bitumen waterproofing membrane type Index Flexter Flex Testudo Spunbond Poliestere or similar approved, 4 mm thick, reinforced with composed “non woven fabric” single –strand Spunbond polyester, flexibility to low temperature -25 C, stabilized with rot-proof fiber-glass and certified with ITC Agreement.
- Final layer elastoplastomeric polymer-bitumen waterproofing membrane type Index Mineral Reflex White Flexter Testudo FR TRIARM or similar approved, 4 mm thick, reinforced elastoplastomeric polymer-distilled bitumen membrane, with a distilled bitumen, plastomer and elastomer base, 3-layer composite stabilized Spunbond polyester reinforcement, flexibility to low temperature -15 C, special high saturation and luminosity white mineral self-protection for energy saving and the reduction of “urban heat islands” having Solar Reflectance Index SRI > 52- 54.
- Item includes two exhaust vents and any other items to provide a job performed in a workmanlike
52.00 SQ.M
5.4.c Furnish and installation of new hot galvanized factory painted metal flashing, thickness 8/10, development 25 cm, color dark brown. Item includes scaffolding and any other work to provide a job
30.90 L.M.
5.4.d Paint exterior walls surfaces consisting of: water jet blasting, surface preparation as necessary including removal of plaster that sounds hollow prior to start any painting activities. Item foreseen the furnishing and application of two coats of mineral fiber-reinforced smoothing (“rasatura armata”), specific for restoration, minimum thickness 6 mm, type Rofix Renoplus or equivalent, plaster repair where necessary using the same Rofix product. Item includes application of siloxane primer “ PP 301 HYDRO LF” or equivalent and installation of 150 gr/SqM alkali- resistant fiberglass mesh “P-50”. Furnish and installation of protective high thickness finishing layer, type Rofix “Protec ai silossani”, grain size 1.5 mm, or equivalent, including application of one coat of fixative “Primer Premium” and any other work to provide a job performed in a work-manlike manner. Installation of above described products will be strictly performed according to manufacturer installation instructions.
106.50 SQ.M.
5.4.e Supply and installation of new external pre-painted hot deep galvanized steel door and frame, thickness 20/10, double wing with louvers on top and bottom, dimensions 160x220 cm, having the same geometry of the existing doors, including Cisa lock, stainless steel handle, insect screen, gaskets color dark brown and metal flashing above doors (8/10 thickness). Item includes removal of existing metal doors and frames, loading and transportation of resulting material to authorized dump and any other work to provide a job performed in a work-manlike manner.
31CES/CENMP 9
Building 309 :
5.5.a Removal of existing double layer waterproofing materials on the flat roof, cleaning, including existing metal gutters and flashing. Item includes removal and re-installation of existing lighgting protection system, loading and transportation of resulting materials to authorized dump, dumping fees and any other work to provide a job performed in a work-manlike manner.
205.00 SQ.M.
5.5.b Provide manpower, materials and equipment to remove existing metal grille and railing on the roof, including removal of supports, cutting operation, lifting equipment, loading and transportation of resulting materials to authorized dump. Item includes furnish and installation of metal stairs ( 3 steps) welded on existing stair, 1.10 mt width, railing, having the same characteristic of existing stairs and any other work to give a job performed in a workmanlike manner.
L.S.
5.5.c Furnish and installation on new roof package consisting:
- Perimeter wooden joist cm 8x8 cm, pre-treated with impregnating agent anchored on concrete every 70 cm.
- Solvent-based primer type Index Indever or similar approved. Bituminous solution containing and quick-drying solvents.
- Elastoplastomeric polymer-bitumen draining waterproofing membrane and vapour barrier with an embossed upper face type Index Prominent or similar approved, reinforced with "non-woven fabric" polyester stabilized with roof-proof fiberglass, weight 4.0 kg/mq.
- 8 cm thick insulation polyurethane foam “ Stiferite Class BH” or equivalent with upper surface covered with bituminous coating.
- First layer Elastoplastomeric polymer-bitumen waterproofing membrane type Index Flexter Flex Testudo Spunbond Poliestere or similar approved, 4 mm thick, reinforced with composed “non woven fabric” single –strand Spunbond polyester, flexibility to low temperature -25 C, stabilized with rot-proof fiber-glass and certified with ITC Agreement.
- Final layer elastoplastomeric polymer-bitumen waterproofing membrane type Index Mineral Reflex White Flexter Testudo FR TRIARM or similar approved, 4 mm thick, reinforced elastoplastomeric polymer-distilled bitumen membrane, with a distilled bitumen, plastomer and elastomer base, 3-layer composite stabilized Spunbond polyester reinforcement, flexibility to low temperature -15 C, special high saturation and luminosity white mineral self-protection for energy saving and the reduction of “urban heat islands” having Solar Reflectance Index SRI > 52- 54.
- Item includes exhaust vents n.1/30 sq.m. and any other items to provide a job performed in a workmanlike manner.
205.00 SQ.M
5.5.d Furnish and installation of new hot copper gutters, thickness 8/10, development 100 cm. Item includes scaffolding and any other work to provide a job performed in a work-manlike manner.
61.60 L.M.
31CES/CENMP 10
5.5.e Paint exterior walls surfaces consisting of: water jet blasting, surface preparation as necessary including removal of plaster that sounds hollow prior to start any painting activities. Item foreseen the furnishing and application of two coats of mineral fiber-reinforced smoothing (“rasatura armata”), specific for restoration, thickness 6-7 mm, type Rofix Renoplus or equivalent, plaster repair where necessary using the same Rofix product. Item includes application of siloxane primer “ PP 301 HYDRO LF” or equivalent and installation of 150 gr/SqM alkali- resistant fiberglass mesh “P-50”. Furnish and installation of protective high thickness finishing layer, type Rofix “Protec ai silossani”, grain size 1.5 mm, or equivalent, including application of one coat of fixative “Primer Premium” and any other work to provide a job performed in a work-manlike manner. For concrete surfaces contractor shall apply one coat of solvent primer type Sigmafix white and two coats of acrylic anti carbonate paint type SIGMAFACADE TOPCOAT or equivalent. Item includes removal and re-installation of A/C external split units (four), furnishing and installation of n. eight (8) new external aluminum louvers, having average size 80x60 cm.
216.50 SQ.M.
5.5.f Furnish and installation of six (6) new pre-painted galvanized downspouts, dia. 10 cm, thickness 8/10, including splash blocks. Item includes removal and disposal of existing downspouts to authorized dump site, scaffolding and any other work to provide a job performed in a work-manlike manner.
21.00 L.M.
5.5.g New painting for exterior metal stairs, existing railing on the roof and external sprinkler pipeline.
Contractor shall apply one coat of universal rust proof paint on rusted areas type Duli or equivalent and two coats of solvent synthetic enamel paint based on alkylate resins (“smalto alchidico”) type Caparol “Capalac Buntlack” or equivalent. Contractor shall remove all harmful substances from all metal surfaces using a jet blasting method, sandpaper, wire brush or sub with steel wool over the entire surface and scrape where necessary to remove damaged paint. Contractor shall clean all rusted spots down to bare metal including spots where rust discoloration appears through the existing coating and apply one extra coat of anticorrosive paint.
70.00 SQ.M.
5.5.h Furnish and installation of multipurpose steel doors, brand NINZ PROGET or equivalent, 6 cm thickness, “Sendzimir” processed hot-galvanized sheet metal, press folded and electro-welded, heat insulated treated mineral wool packing rigidly joined to the sheet metal, equipped with panic bars at three point locking mechanism, stainless steel handle, stainless steel kicks plates on both sides, sealing, gaskets, cylinders, doors closer, including special frames extension for proget doors. Item includes removal, transportation and disposal of existing doors and frames to public dump, dumping fees and any other work to provide a job performed in a workmanlike manner.
I) door with dimensions 90x215 cm equipped with multipurpose rectangular window 400x600 mm, metal window frame and push bar;
2 Each II) door with dimensions 90x215 cm.
31CES/CENMP 11
Building 44203 :
5.6.a Removal of existing double layer waterproofing materials on the flat roof, including removal of existing metal flashing, loading and transportation of resulting materials to authorized dump, cleaning, scaffolding and any other work to provide a job performed in a work-manlike manner.
15.50 SQ.M.
5.6.b Furnish and installation on new roof package consisting:
quick-drying solvents.
- First layer Elastoplastomeric polymer-bitumen waterproofing membrane type Index Flexter Flex Testudo Spunbond Poliestere or similar approved, 4 mm thick, reinforced with composed “non woven fabric” single –strand Spunbond polyester, flexibility to low temperature -25 C, stabilized with rot-proof fiber-glass and certified with ITC Agreement.
- Final layer elastoplastomeric polymer-bitumen waterproofing membrane type Index Mineral Reflex White Flexter Testudo FR TRIARM or similar approved, 4 mm thick, reinforced elastoplastomeric polymer-distilled bitumen membrane, with a distilled bitumen, plastomer and elastomer base, 3-layer composite stabilized Spunbond polyester reinforcement, flexibility to low temperature -15 C, special high saturation and luminosity white mineral self-protection for energy saving and the reduction of “urban heat islands” having Solar Reflectance Index SRI > 52- 54.
- Item includes two exhaust vents and any other items to provide a job performed in a workmanlike
15.50 SQ.M
5.6.c Furnish and installation of new hot galvanized factory painted metal flashing, thickness 8/10, development 35 cm, color dark brown. Item includes scaffolding and any other work to provide a job
16.00 L.M.
5.6.d Paint exterior walls surfaces consisting of: water jet blasting, surface preparation as necessary including removal of plaster that sounds hollow prior to start any painting activities. Item foreseen the furnishing and application of two coats of mineral fiber-reinforced smoothing (“rasatura armata”), specific for restoration, thickness 6 mm, type Rofix Renoplus or equivalent, plaster repair where necessary using the same Rofix product. Item includes application of siloxane primer “ PP 301 HYDRO LF” or equivalent and installation of 150 gr/SqM alkali- resistant fiberglass mesh “P- 50”. Furnish and installation of protective high thickness finishing layer, type Rofix “Protec ai silossani”, grain size 1.5 mm, or equivalent, including application of one coat of fixative “Primer Premium” and any other work to provide a job performed in a work-manlike manner. Installation of above described products will be strictly performed according to manufacturer installation instructions.
56.00 SQ.M.
31CES/CENMP 12
Building 81244 :
5.7.a Removal of existing double layer waterproofing materials on the flat roof, loading and transportation of resulting materials to authorized dump, cleaning, scaffolding. Item includes removal and re-installation of existing lighgting protection system and any other work to provide a job performed in a
28.00 SQ.M.
5.7.b Furnish and installation on new roof package consisting:
quick-drying solvents.
- First layer Elastoplastomeric polymer-bitumen waterproofing membrane type Index Flexter Flex Testudo Spunbond Poliestere or similar approved, 4 mm thick, reinforced with composed “non woven fabric” single –strand Spunbond polyester, flexibility to low temperature -25 C, stabilized with rot-proof fiber-glass and certified with ITC Agreement.
- Final layer elastoplastomeric polymer-bitumen waterproofing membrane type Index Mineral Reflex White Flexter Testudo FR TRIARM or similar approved, 4 mm thick, reinforced elastoplastomeric polymer-distilled bitumen membrane, with a distilled bitumen, plastomer and elastomer base, 3-layer composite stabilized Spunbond polyester reinforcement, flexibility to low temperature -15 C, special high saturation and luminosity white mineral self-protection for energy saving and the reduction of “urban heat islands” having Solar Reflectance Index SRI > 52- 54.
- Item includes two exhaust vents and any other items to provide a job performed in a workmanlike manner.
28.00 SQ.M
5.7.c Paint exterior walls surfaces consisting of: water jet blasting, surface preparation, special smoothing plaster (rasante) for damaged surfaces, application of one coat of solvent primer type Sigmafix white or equivalent and two coats of acrylic anti carbonate paint type SIGMAFACADE TOPCOAT or equivalent, particularly suitable for the protection of façade and reinforced concrete walls. Surfaces to be treated must be fully cured, clean and dry, free from dust and part with poor adherence, including scaffolding and any other work to provide a job performed in a work-manlike manner.
67.60 SQ.M.
5.7.d Supply and installation of new external pre-painted hot deep galvanized steel door and frame, thickness 20/10, double wing with louvers on top and bottom, dimensions 200x250 cm, having the same geometry of the existing doors, padlock, stainless steel handle, gaskets, color dark brown and accessories. Item includes removal of existing metal doors and frames, loading and transportation of resulting material to authorized dump, dumping fees and any other work to provide a job performed in a work-manlike manner.
3 Each
5.7.e Furnish and installation of new factory painted metal flashing, thickness 8/10, development 35 cm, color dark brown, to be installed above existing door openings. Furnish and installation of two (2) new aluminum louvers, dim. 80x60 cm. Item includes removal and disposal of existing metal flashing and louvers and any other work to provide a job performed in a work-manlike manner.
L.S.
31CES/CENMP 13
6. APPLICABLE MASTER SPECIFICATIONS
The following sections of the Master Specifications for construction projects of the Air Base in Aviano (PN), Italy, dated November 2005 and applicable modifications, shall be applicable to the present project, together with the List of Work Items to be performed:
01100 GENERAL CONDITIONS
01101R PROJECT SIGN
07220 08110 09900
ROOF INSULATION
STEEL DOORS AND STEEL FRAMES
PAINT AND COATING
7. ATTACHMENTS:
• SEON DRAWINGS
• UUUY 17-1043 PHOTOS ALBUM
• UUUY 17-1043 SUBMITTALS
• 01100 GENERAL CONDITIONS
• 01101R PROJECT SIGN
• 07220 ROOF INSULATION
• 08110 STEEL DOORS AND STEEL FRAMES
• 09900 PAINT AND COATING
Date: APRIL 2017
File details come from the government source that posted it. Updated .