This is an Asbestos Management Survey Report for AEDY-562 (Housing Supply Storage Facility F) at RAF Alconbury in Huntingdon, Cambridgeshire, conducted on June 10, 2021. The survey was performed by SOCOTEC Asbestos Limited, a UKAS-accredited Type C Inspection Body, on behalf of Amey Defence Services Ltd under a USVF Bridging Contract.
The survey identified asbestos-containing materials (ACMs) in one confirmed sample and three presumed materials. Sample 011 (gaskets to horizontal flanges in the Ground Floor Stacks Storage area, identified as 15 items) tested positive for chrysotile (white asbestos) with a Material Risk Score of 5 and Priority Risk Score of 5, resulting in a Total Risk Score of 10, with a management recommendation and 12-month action timescale. Sample P001 (gaskets to high-level flanges, 20 items, inaccessible due to height restriction) was presumed to contain chrysotile based on visual consistency with the confirmed sample, yielding the same risk scores. Additional associated samples AWS-011 on the mezzanine floor (Washer Storage, 4 gasket items to horizontal flanges) also tested positive for chrysotile with a Total Risk Score of 9 and 12-month management recommendation. Sixteen other samples from insulating board panels, floor tiles, textured coatings, and bitumen pads all tested negative for asbestos (NADIS). Areas with limited or no access included high-level locations in Stacks Storage and the External area (height restrictions) and below-flooring areas in the Female and Male WC facilities (fixed construction). The report recommends ongoing management and inspection of confirmed ACMs within 12 months and notes that further asbestos materials may be concealed within building fabric or sealed voids.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| building 562 asbestos report.docx | DOCX document | |
| AEDY_00562_1.pdf | ||
| AEDY_00562.pdf | ||
| RFI Response.docx | DOCX document | |
| AEDY_00562_2.pdf | ||
| Attachment 1 - Section L and M.pdf | ||
| Attachment 3 - Drawing.pdf | ||
| Attachment 1 - Section L and M.pdf | ||
| Solicitation - FA557026R0002.pdf | ||
| Attachment 2 - Statement_of_Objectives.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Survey Ref: 139617-021 Page 1 of 10
ASBESTOS MANAGEMENT SURVEY REPORT
For
AMEY DEFENCE SERVICES LTD (USVF BRIDGING CONTRACT)
Of
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
ALCO01000562
139617-021
Produced by SOCOTEC Asbestos Ltd, a wholly owned subsidiary of SOCOTEC www.socotec.com
Bretby Business Park, Ashby Road, Bretby, Burton upon Trent, Staffordshire DE15 0YZ http://www.socotec.com/
Survey Ref: 139617-021 Page 2 of 10
Site Customer:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
Amey Defence Services Ltd (USVF Bridging Contract) 1st Floor Swales Pavilion RAF Wyton Huntington
PE28 2EA
Customer Contact: Andrew Flanagan Survey Date: 10/06/2021
Surveyor(s): Lee Crush
Consultant:
SOCOTEC Asbestos Limited Authorised by:
Lee Crush Surveyor
Technical Review by:
Victoria Carim Surveyor
Report Issue date: 30/06/2021
Tel +44 (0) 1283 554499
Ecs.bretby@socotec.com
Bretby Business Park, Ashby Road, Burton upon Trent, Staffordshire
DE15 0YZ
Survey Ref: 139617-021 Page 3 of 10
EXECUTIVE SUMMARY & RECOMMENDATIONS
A Management asbestos survey was carried out at AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA.
Asbestos was found in one sample. There were 3 presumed or strongly presumed materials identified.
Table 1 Summary of ACM's
S a m p le
R e fe re n c
R is k S c o re
B u ild in g
Area Description Material
M a te ri a l R k
P ri o ri ty R
Action Timescale for Action
AWS
- 011
10 001 Ground Floor - 1001-Stacks Storage
Gaskets to horizontal flanges x15
5 5 Manage
12 months
P001 10 001 Ground Floor - 1001-Stacks Storage
Gaskets to high level flanges
5 5 Manage
Presumption Reasons: Height Restriction.
12 months
011 10 001 Ground Floor - 1001-Stacks Storage
Gaskets to horizontal
5 5 Manage
AWS
- 011
9 001 Mezzanine Floor - 2002-Washer storage
Gaskets to horizontal
5 4 Manage
Table 2 Summary of Areas of Limited, Restricted or Partial Access
Area No
Building Area Description Reason
1001 001 Ground - Stacks Storage High Level Height Restriction
1006 001 Ground - Female WC Below flooring Fixed Construction
1007 001 Ground - Male WC including lobby Below flooring
Fixed Construction
EXT 001 External - External High level Height Restriction
The table above provides a list of locations of limited access at the time of inspection by the surveyor with reasons for access issues. Such areas must be assumed to contain asbestos until inspected.
Survey Ref: 139617-021 Page 4 of 10
FULL SURVEY REPORT
TABLE OF CONTENTS
EXECUTIVE SUMMARY & RECOMMENDATIONS
SECTION 1 INTRODUCTION
SECTION 2 SITE DESCRIPTION
SECTION 3 SPECIFIC NOTES
SECTION 4 SURVEYS AND SAMPLING METHODOLOGIES
SECTION 5 BULK SAMPLE ANALYSIS METHODOLOGIES
SECTION 6 RISK ASSESSMENT
APPENDIX A Site Register
APPENDIX B Material Assessment Sheets
APPENDIX C Drawings
APPENDIX D Laboratory Test Certificate(s)
APPENDIX E Definitions and Guidance Notes
Survey Ref: 139617-021 Page 5 of 10
SECTION 1 INTRODUCTION
1.1 SOCOTEC Asbestos Limited was instructed by Andrew Flanagan of Amey Defence Services
Ltd (USVF Bridging Contract), to carry out a Management asbestos survey of AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA in accordance with HSE document HSG 264 and in-house approved documented method SCI/ASB/001.
1.2 The scope of the works was to carry out an Asbestos Management Survey on the premises as instructed by the Customer as follows: Asbestos Management Survey to be carried out in accordance with the guidance provided in the Health and Safety Executive Publication HSG264 Asbestos. It is required that ALL rooms, spaces, loft spaces, roof spaces, areas above suspended ceilings, etc. are accessed and incorporated in the survey and report. The surveyors should target areas at high level in the hangars, wide span buildings and workshops and should be briefed on the strong likelihood of debris/ residues in addition to those already identified in any previous asbestos surveys, re-inspection reports or asbestos registers.
1.3 The following areas were not accessed during the survey following initial discussions with the customer: Limited access to live electrics
1.4 The extent and type of the asbestos containing materials on site was to be summarised in a written report including a detailed site register, survey report sheets and plans.
1.5 The title to this report is vested in the Customer named but title to copyright is retained. The Contracts (Rights of Third Parties) Act 1999 does not apply to the contract with the Customer and the provisions of the said Act are hereby excluded.
1.6 The inspection report shall not be reproduced except in full without the approval of the inspection body and the Customer.
1.7 SOCOTEC Asbestos Ltd is accredited by UKAS as a Type C Inspection Body for surveying for asbestos in premises. Opinions, interpretations, priority risk assessments and total risk scores are outside the scope of accreditation.
1.8 Fibrous materials may exist within the property which are not ACMs. Where, in the judgment of the surveyor, the material is clearly not asbestos then the surveyor will record the findings in the Construction Register. However the material will have been inspected unless it was in an area of no access or is specifically excluded from the report.
SECTION 2 SITE DESCRIPTION
2.1 The site consisted of MoD Base.
Table 2.1: Summary of buildings surveyed and survey type at AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA.
Property Ref / UPRN Building Description Survey Type
ALCO010005
Single storey warehouse of metal construction with mezzanine floor and offices.
Management
Survey Ref: 139617-021 Page 6 of 10
SECTION 3 SPECIFIC NOTES
3.1 The scope and terms of works were as agreed during the tender process with the Customer, including a discussion on areas of possible no-access (see section 1.2 and 1.3). We confirm that in preparing this report that we have exercised all reasonable skill and care bearing in mind the project objectives, the agreed scope of works and prevailing site conditions.
3.2 Asbestos containing materials (ACMs) concealed behind other asbestos containing materials may not have been located during the survey due to the potential for fibre release. It should be assumed that further asbestos containing materials may be present until proven otherwise.
3.3 Water absorption tests have not been carried out on board or cement materials and thus such materials which have been referred to within this report as asbestos insulating board (AIB) or asbestos cement are done so based solely upon their physical appearance and using the technicians judgement. A water absorption measurement test, as detailed in paragraph 17 of L143 Work with Materials Containing Asbestos ACOP, is required to determine whether a material is legally classified as asbestos cement or not. Asbestos cement in a dry state absorbs less than 30% water by weight.
3.4 A Management Survey report should not be used as the basis for an asbestos removal specification. A Refurbishment or Demolition survey report may be used as a basis for a specification. Note that all dimensions referred to in this report are approximate and should not be used for the calculation of priced measures. For Management surveys, the recommendations indicated on the asbestos register are overridden if the building is due for demolition or major structural alteration. Where materials are suspected to be present and consist of or contain asbestos, contractors should (prior to commencing refurbishment works) first confirm the existence of such materials under controlled conditions such as a Refurbishment or Demolition survey and in accordance with Control of Asbestos Regulations Regulation 5 and the Construction (Design and Management) Regulations.
3.5 All reasonable efforts were made to identify the presence of materials containing asbestos within the areas of the building. It is known that asbestos materials are frequently concealed within the fabric of buildings or within sealed building voids accordingly it is not possible to regard the findings of any survey as being definitive. The nature of the survey was a non-destructive inspection at key locations of accessible voids and areas.
SECTION 4 SURVEY AND SAMPLING METHODOLOGY
4.1 Management Survey
4.1.1 The purpose of this survey was to locate as far as reasonably practicable, the presence and extent of any suspect ACMs in the building and assess their condition, with representative samples being collected and analysed for the presence of asbestos.
Samples from each type of suspect ACM found were collected and analysed to confirm or refute the surveyor's judgement. If the material sampled was found to contain asbestos, other similar homogeneous materials used in the same way in the building have been strongly presumed to contain asbestos.
4.1.2 The survey was carried out in accordance with HSG 264, SOCOTEC’s internal procedure SCI/ASB/001 and the specific requirements of the Customer.
4.2 Abbreviations used in the text
Survey Ref: 139617-021 Page 7 of 10
AWS Associated with sample. Visually consistent with sampled material.
ACM Asbestos Containing Material
NSR No sample required (Area has been inspected and no suspicious samples identified)
NA No Access (Access not reasonably practicable)
P Presumed to contain asbestos. Sample required to confirm absence or presence of asbestos in item
CAR Control of Asbestos Regulations (2012)
X All samples prefixed with an X were not taken by SOCOTEC Asbestos, however the data was provided by the client for inclusion within the report and the integrity of the data has been reviewed by SOCOTEC Asbestos Ltd in accordance with our internal procedures.
SECTION 5 BULK SAMPLE ANALYSIS METHODOLOGY
5.1 Bulk sample analysis was carried out in accordance with SOCOTEC Asbestos Limited’s internal procedure SCI/ASB/007, based on the Health and Safety Executive publication
HSG 248.
5.2 SOCOTEC Asbestos is a UKAS-accredited testing body No. 1089, ensuring compliance with the requirements of BS EN ISO/IEC 17025:2017 General criteria for the operation of various types of bodies performing testing.
SECTION 6 RISK ASSESSMENT
6.1 Risk Assessment Methodology & Interpretation
6.1.1 Each location of asbestos has a risk assessment which is composed of two elements:
Material Risk Assessment
Priority Risk Assessment
6.1.2 The table below identifies the differences between the two elements, their purpose and the guidance to which it relates and which SOCOTEC Asbestos Limited adhere.
Survey Ref: 139617-021 Page 8 of 10
Table 6.1: Summary of Risk Assessment
Risk Assessment
Type
Purpose
Guidance and Algorithm used by SOCOTEC Asbestos Limited
Material Risk
Identification of the type and condition of the ACM and the ease with which it will release fibres if disturbed
HSG 264 – ‘Asbestos – The survey guide.’ – Appendix 4.
In house procedure SCI/ASB/001, based on the above
Priority Risk
Identification of the likelihood of disturbance
HSG 227 – ‘A
comprehensive guide to managing asbestos in premises’
In house procedure SCI/ASB/001, based on the above
6.1.3 The combined Material and Priority Risk Assessment scores provide a Total Risk Score for the asbestos material and may be used to determine the appropriate management procedure.
6.1.4 The Priority and Material Assessments were made based upon the conditions of the materials and their application at the time of survey/inspection, and as such SOCOTEC cannot accept liability for assessments provided when changes in condition and/or use have occurred subsequent to the survey. The duty holder should be aware that if the use of the building changes, then the assessment should be reviewed by a responsible person as part of the ongoing management plan, and this is the responsibility of the duty holder to manage.
Survey Ref: 139617-021 Page 9 of 10
Table 6.2 Material Risk Assessment Algorithm
Sample variable Score Example of scores
Asbestos reinforced composites (plastics, resins, mastics, roofing felts, vinyl floor tiles, asbestos cement)
Product type (or debris from product)
AIB, millboards, textiles, gaskets, ropes and asbestos paper
Thermal Insulation (e.g. pipe and boiler lagging), sprayed asbestos
Good condition, no visible damage
Extent of damage /deterioration
Low damage, a few scratches, broken edges on board, tiles etc.
Medium damage; significant breakage of materials or several small areas of damage revealing loose asbestos fibres
High damage or delamination of materials, sprays and thermal insulation. Visible asbestos debris
Composite materials: reinforced plastics, resins, vinyl tiles
Surface treatment
Enclosed sprays and lagging, AIB (with exposed face painted or encapsulated) asbestos cement sheets etc.
Unsealed AIB, or encapsulated lagging and sprays
Unsealed lagging and sprays
0 No Asbestos Detected
Asbestos type 1 Chrysotile
2 Amphibole excluding Crocidolite
3 Crocidolite
Score Potential to release asbestos fibres
10 or more High
7-9 Medium
5-6 Low
4 or less Very low
Survey Ref: 139617-021 Page 10 of 10
Table 6.3 Priority Risk Assessment Algorithm
Assessment Factor
Score Examples of score variables
1. Normal Occupant Activity Main type of activity in area
Rare disturbance activity, e.g. little used store room) Low disturbance activities, (e.g. office type activity) Periodic disturbance (e.g. industrial or vehicular activity which may contact ACMs) High levels of disturbance, (e.g. Fire door with AIB sheet in constant use)
2. Likelihood of Disturbance
a) Location
b) Accessibility
c) Extent/Amount
Outdoors Large rooms or well ventilated areas Rooms up to 100m2
Confined spaces Usually inaccessible or unlikely to be disturbed Occasionally likely to be disturbed Easily disturbed Routinely disturbed Small amounts or items (e.g. strings, gaskets)
10m² or 10m pipe run
>10m² to 50m² or >10m to 50m pipe run >50m2 or >50m pipe run
Average Score = a + b + c / 3
3. Human Exposure Potential
a) Number of occupants
b) Frequency of use of area
c) Average time area in use
None 1 to 3 4 to 10 >10 Infrequent Monthly Weekly Daily <1 hour >1 to <3 hours >3 to <6 hours >6 hours
Average Score = a + b + c / 3
4. Maintenance Activity
a) Type of maintenance activity
b) Frequency of maintenance activity
Minor disturbance (e.g. possibility of contact when gaining access) Low disturbance (e.g. changing light bulbs in AIB ceiling) Medium disturbance (e.g. lifting one or two AIB ceiling tiles to access a valve) High levels of disturbance (e.g. removing a number of AIB ceiling tiles to replace a valve or for re-cabling) ACM unlikely to be disturbed for maintenance <1 per year >1 per year >1 per month
Average Score = a + b / 2
Total Priority Assessment Score =1 + 2 + 3 + 4
Appendix A
SITE REGISTER(S)
SITE REGISTER
Survey Report Ref: 139617-021-001 Site Address: AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
Building Address: As Above
Building Reference / UPRN: ALCO01000562 Client: Amey Defence Services Ltd (USVF Bridging Contract)
Date of Inspection 10/06/2021
KEY: All scores are subjective only and are based on information available at the time of the assessment. Inspections may be samples or associated samples (AWS). Comments and observations are outside the scope of UKAS accreditation. All information within this register must be read in conjunction with all other sections of the report. Please refer to Section 6.4 for information regarding Priority Risk Scores
Asbestos Type Product Type Extent of Damage Areas of No / Limited Access
0 = No asbestos detected in sample 0 = No asbestos detected in sample 0 = No visible damage FS = Fixed Seating SD = Service Ducts FV = Floor Voids
PV=Partition Wall Void SC=Above Suspended Ceiling LA=Loft / Attic
1 = Chrysotile (white) asbestos 1 = Plastics, mastics, felts, vinyl floor tiles, paints, dec. finishes, cement etc.
1 = Few scratches / marks, broken edges etc FD = Floor Ducts SB = Structural Boxing SV = Structural Voids
EE=Electrical Equip.
HE=Heating Equipment FP=Fixed Panelling
2 = Amosite (brown) asbestos 2 = AIB, textiles, gaskets, rope, paper etc; 2 = Sig breakage / many small areas of damage to friable material DL = Dry Lining or Boxing FC = Fixed Ceilings UC=Under Fitted Floor Covering CV=Ceiling Voids
DF=Within Door Frame WF=Within Window Frame HL=High Level PE = Plant / Equipment (includes lift machinery)
3 = Crocidolite (blue) asbestos 3 = lagging, spray coatings, loose asbestos etc 3 = High damage / visible debris
ASBESTOS REGISTER
A re a N
Area Description Material Description
Approx size of item
Sample or Associate Sample
Reference
Material Risk
M a te ri a l R is k R a ti n
A s b e s to s T y ro d u c t T y
E x te n t o f
D a m a rf a c e T re a tm e n t
N o rm a l O c c u p a n t
A c ti v it y
L ik e lih o o d o f
D is tu rb a n
H m a n
E x p o s te n ti a l
M a in te n a n c e A c ti v o ri ty R is k R a ti
O v e ra ll R
Recommended Actions & Timescales
Ground Floor - Stacks Storage
Gaskets to horizontal flanges x15
Items
AWS 011 1 2 1 1 5 1 1 2 1 5 10
Inspection Required in Limited Access Area / Manage - 12 months / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Gaskets to high level flanges
Items
P001 1 2 1 1 5 2 0 2 1 5 10 Inspection Required in Limited Access Area / Manage - 12 months / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
180 m² 001 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
180 m² 002 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
200 m² 003 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
200 m² 004 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Survey Report Ref: 139617-021-001 Site Address: AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
Building Reference / UPRN: ALCO01000562 Client: Amey Defence Services Ltd (USVF
KEY: All scores are subjective only and are based on information available at the time of the assessment. Inspections may be samples or associated samples (AWS). Comments and observations are outside the scope of UKAS accreditation. All information within this register must be read in conjunction with all other sections of the report. Please refer to Section 6.4 for information regarding Priority Risk Scores
Asbestos Type Product Type Extent of Damage Areas of No / Limited Access
0 = No asbestos detected in sample 0 = No asbestos detected in sample 0 = No visible damage FS = Fixed Seating SD = Service Ducts FV = Floor Voids
PV=Partition Wall Void SC=Above Suspended Ceiling LA=Loft / Attic
1 = Chrysotile (white) asbestos 1 = Plastics, mastics, felts, vinyl floor tiles, paints, dec. finishes, cement etc.
1 = Few scratches / marks, broken edges etc FD = Floor Ducts SB = Structural Boxing SV = Structural Voids
EE=Electrical Equip.
HE=Heating Equipment FP=Fixed Panelling
2 = Amosite (brown) asbestos 2 = AIB, textiles, gaskets, rope, paper etc; 2 = Sig breakage / many small areas of damage to friable material DL = Dry Lining or Boxing FC = Fixed Ceilings UC=Under Fitted Floor Covering CV=Ceiling Voids
DF=Within Door Frame WF=Within Window Frame HL=High Level PE = Plant / Equipment (includes lift machinery)
3 = Crocidolite (blue) asbestos 3 = lagging, spray coatings, loose asbestos etc 3 = High damage / visible debris
A re a size of item
Sample or Associate Sample
Reference
Material Risk
M a te ri a l R is k R a ti s b e s to s T y d u c t T y te n t o f
D a m a rf a c e T re a tm e n t
N o rm a l O c c u p a n t
A c ti v e lih o o d o f
D is tu rb a n m a n
E x p o s te n ti a l
M a in te n a n c e A c ti v o ri ty R is k R a ti e ra ll R
Ground Floor - Stacks Storage
Insulating board panels to wall
200 m² 005 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
200 m² 006 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
200 m² 007 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
200 m² 008 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
180 m² 009 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Insulating board panels to wall
180 m² 010 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Survey Report Ref: 139617-021-001 Site Address: AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
Building Reference / UPRN: ALCO01000562 Client: Amey Defence Services Ltd (USVF
KEY: All scores are subjective only and are based on information available at the time of the assessment. Inspections may be samples or associated samples (AWS). Comments and observations are outside the scope of UKAS accreditation. All information within this register must be read in conjunction with all other sections of the report. Please refer to Section 6.4 for information regarding Priority Risk Scores
Asbestos Type Product Type Extent of Damage Areas of No / Limited Access
0 = No asbestos detected in sample 0 = No asbestos detected in sample 0 = No visible damage FS = Fixed Seating SD = Service Ducts FV = Floor Voids
PV=Partition Wall Void SC=Above Suspended Ceiling LA=Loft / Attic
1 = Chrysotile (white) asbestos 1 = Plastics, mastics, felts, vinyl floor tiles, paints, dec. finishes, cement etc.
1 = Few scratches / marks, broken edges etc FD = Floor Ducts SB = Structural Boxing SV = Structural Voids
EE=Electrical Equip.
HE=Heating Equipment FP=Fixed Panelling
2 = Amosite (brown) asbestos 2 = AIB, textiles, gaskets, rope, paper etc; 2 = Sig breakage / many small areas of damage to friable material DL = Dry Lining or Boxing FC = Fixed Ceilings UC=Under Fitted Floor Covering CV=Ceiling Voids
DF=Within Door Frame WF=Within Window Frame HL=High Level PE = Plant / Equipment (includes lift machinery)
3 = Crocidolite (blue) asbestos 3 = lagging, spray coatings, loose asbestos etc 3 = High damage / visible debris
A re a size of item
Sample or Associate Sample
Reference
Material Risk
M a te ri a l R is k R a ti s b e s to s T y d u c t T y te n t o f
D a m a rf a c e T re a tm e n t
N o rm a l O c c u p a n t
A c ti v e lih o o d o f
D is tu rb a n m a n
E x p o s te n ti a l
M a in te n a n c e A c ti v o ri ty R is k R a ti e ra ll R
Ground Floor - Stacks Storage
Gaskets to horizontal flanges x15
Items
011 1 2 1 1 5 1 1 2 1 5 10 Inspection Required in Limited Access Area / Manage - 12 months / High Level : Limited - Height Restriction
Ground Floor - Stacks Storage
Gaskets to vertical flanges x7
Items
012 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / High Level : Limited - Height Restriction
Ground Floor - Break Room
Beige floor tiles 12 m² 014 0 N/A N/A N/A No Action
Ground Floor - Break Room
Bitumen pad to underside of sink
Items
015 0 N/A N/A N/A No Action
1006 Ground Floor - Female WC No sample required
Inspection Required in Limited Access Area / Below flooring : Limited - Fixed Construction
Ground Floor - Male WC including lobby
Textured coating to ceiling
15 m² 013 0 N/A N/A N/A Inspection Required in Limited Access Area / No Action / Below flooring :
Limited - Fixed Construction
Ground Floor - Appliance office
Survey Report Ref: 139617-021-001 Site Address: AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
Building Reference / UPRN: ALCO01000562 Client: Amey Defence Services Ltd (USVF
KEY: All scores are subjective only and are based on information available at the time of the assessment. Inspections may be samples or associated samples (AWS). Comments and observations are outside the scope of UKAS accreditation. All information within this register must be read in conjunction with all other sections of the report. Please refer to Section 6.4 for information regarding Priority Risk Scores
Asbestos Type Product Type Extent of Damage Areas of No / Limited Access
0 = No asbestos detected in sample 0 = No asbestos detected in sample 0 = No visible damage FS = Fixed Seating SD = Service Ducts FV = Floor Voids
PV=Partition Wall Void SC=Above Suspended Ceiling LA=Loft / Attic
1 = Chrysotile (white) asbestos 1 = Plastics, mastics, felts, vinyl floor tiles, paints, dec. finishes, cement etc.
1 = Few scratches / marks, broken edges etc FD = Floor Ducts SB = Structural Boxing SV = Structural Voids
EE=Electrical Equip.
HE=Heating Equipment FP=Fixed Panelling
2 = Amosite (brown) asbestos 2 = AIB, textiles, gaskets, rope, paper etc; 2 = Sig breakage / many small areas of damage to friable material DL = Dry Lining or Boxing FC = Fixed Ceilings UC=Under Fitted Floor Covering CV=Ceiling Voids
DF=Within Door Frame WF=Within Window Frame HL=High Level PE = Plant / Equipment (includes lift machinery)
3 = Crocidolite (blue) asbestos 3 = lagging, spray coatings, loose asbestos etc 3 = High damage / visible debris
A re a size of item
Sample or Associate Sample
Reference
Material Risk
M a te ri a l R is k R a ti s b e s to s T y d u c t T y te n t o f
D a m a rf a c e T re a tm e n t
N o rm a l O c c u p a n t
A c ti v e lih o o d o f
D is tu rb a n m a n
E x p o s te n ti a l
M a in te n a n c e A c ti v o ri ty R is k R a ti e ra ll R
Ground Floor - Furniture
Mezzanine Floor - Washer storage
Gaskets to horizontal flanges x15
Items
AWS 011 1 2 1 1 5 1 1 1 1 4 9 Manage - 12 months
Mezzanine Floor - Washer storage
Red floor tiles with bitumen adhesive
10 m² 016 0 N/A N/A N/A No Action
Mezzanine Floor - Inventory office
Furnishing management
EXT External - External
Inspection Required in Limited Access Area / High level : Limited - Height Restriction
Survey Report Ref: 139617-021-001 Site Address: AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
Building Reference / UPRN: ALCO01000562 Client: Amey Defence Services Ltd (USVF
CONSTRUCTION REGISTER
Area No Area Description Floor Walls Ceiling Other
Ground Floor - Stacks Storage
Concrete floor S001-S008 insulating board panels
Metal profile sheet ceiling,metal beams,plastic wrapped mmmf insulated metal pipework, presumed high level gaskets to flanges
Ground Floor - Break Room
S014 beige floor tiles and adhesive to concrete floor
Plasterboard walls Plasterboard ceiling Metal and plastic pipework beneath sink.
Ground Floor - Female
WC
Fitted modern vinyl flooring Brick masonry wall with ceramic tiles, laminated timber panels creating cubicle,timber panel behind extractor fan.
Plasterboard ceiling Ceramic cistern,metal and plastic pipework
Ground Floor - Male WC including lobby
Fitted modern vinyl flooring Brick masonry walls with ceramic tiles, laminated timber panels creating cubicle.
S013 textured coating to plasterboard ceiling.
Ceramic cisters,metal and plastic pipework.
Ground Floor - Appliance office
Carpet tiles to concrete floor Plasterboard walls with modern plastic skirting
Timber ceiling above modern suspended ceiling
Modern electric wall heater
Ground Floor - Furniture office
Carpet tiles to concrete floor Plasterboard walls with modern plastic skirting
Timber ceiling above modern suspended ceiling
Modern electric wall heater.
Mezzanine Floor - Washer storage
Timber floor, S016 red floor tile with bitumen adhesive to timber floor.
Sampled insulating board from stacks storage 1001.
Metal profile sheet, metal beams,foil wrapped mmmf insulated metal pipework.
Inventory office
Carpet to timber floor Plasterboard walls Timber ceiling above modern suspended ceiling
Modern electrics, modern electric wall heaters.
Mezzanine Floor - Furnishing management office
Carpet to timber floor Plasterboard walls Timber ceiling above modern suspended ceiling
Modern electric wall heaters.
EXT External - External Concrete floor Metal profile sheet walls N.A Plastic rain goods.
Survey Ref: 139617-021
Appendix B
MATERIAL ASSESSMENT SHEETS
MATERIAL ASSESSMENT SHEET
SITE / AREA / INSPECTION DETAILS
Client: Amey Defence Services Ltd (USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA
Area Description:
Stacks Storage
Building: ALCO01000562 Material Description: Insulating board panels to wall
Building Address:
As Above Survey Report Reference:
139617-021-001
ASSESSMENT Sample No: 001
Material Risk: N/A Position: Internal
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 180 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
Normal Occupant Activity:
Comments: Likelihood of Disturbance:
Human Exposure Potential:
Maintenance Activity : Total Risk Score: N/A
SITE / AREA / INSPECTION DETAILS
Client: Amey Defence Services Ltd (USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 002
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 180 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 003
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 200 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 004
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 200 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 005
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 200 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 006
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 200 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
Comments:
Some areas have small holes/dents.
Likelihood of
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 007
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 200 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 008
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 200 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
Comments:
Some areas have small holes/dents.
Likelihood of
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 009
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 180 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: 010
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 180 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building: ALCO01000562 Material Description: Gaskets to horizontal flanges x15
Building Address:
As Above Survey Report
ASSESSMENT Sample No: 011
Material Risk: 5 Position: Internal
Asbestos Type: 1 - Chrysotile Approx Size of Item: 15 Items
Product Type: 2 - AIB, Millboard, gaskets, paper etc COMMENTS AND RECOMMENDATIONS:
Extent of Damage: 1 - Low damage Timescale for Recommendation : 12 months
Surface Treatment:
1 - Enclosed sprays and lagging, AIB, AC sheets etc Recommendation: Manage
Priority Risk: 5
Normal Occupant Activity:
1 - Low Disturbance
Comments: Likelihood of Disturbance:
1 - Low Likelihood of Disturbance
Human Exposure Potential:
2 - Medium Human Exposure Potential
Maintenance Activity : 1 - Low Risk Maintenance Activity Total Risk Score: 10
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building: ALCO01000562 Material Description: Gaskets to vertical flanges x7
Building Address:
As Above Survey Report
ASSESSMENT Sample No: 012
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 7 Items
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building Address:
As Above Survey Report
ASSESSMENT Sample No: AWS - 011
Asbestos Type: 1 - Chrysotile Approx Size of Item: 4 Items
Product Type: 2 - AIB, Millboard, gaskets, paper etc COMMENTS AND RECOMMENDATIONS:
Extent of Damage: 1 - Low damage Timescale for Recommendation : 12 months
Surface Treatment:
1 - Enclosed sprays and lagging, AIB, AC sheets etc Recommendation: Manage
Priority Risk: 5
Normal Occupant Activity:
1 - Low Disturbance
Comments: Likelihood of Disturbance:
1 - Low Likelihood of Disturbance
Human Exposure Potential:
(USVF Bridging Contract)
Area No: 1001
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Building: ALCO01000562 Material Description: Gaskets to high level flanges
Building Address:
As Above Survey Report
ASSESSMENT Sample No: P001
Asbestos Type: 1 - Chrysotile Approx Size of Item: 20 Items
Product Type: 2 - AIB, Millboard, gaskets, paper etc COMMENTS AND RECOMMENDATIONS:
Extent of Damage: 1 - Low damage Timescale for Recommendation : 12 months
Surface Treatment:
1 - Enclosed sprays and lagging, AIB, AC sheets etc Recommendation: Manage
Priority Risk: 5
Normal Occupant Activity:
2 - Periodic Disturbance
Comments:
Presumption Reason: Height Restriction
Likelihood of Disturbance:
0 - Very Low Likelihood of Disturbance
Human Exposure Potential:
(USVF Bridging Contract)
Area No: 1004
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Break Room
Building: ALCO01000562 Material Description: Beige floor tiles
Building Address:
As Above Survey Report
ASSESSMENT Sample No: 014
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 12 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1004
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Break Room
Building: ALCO01000562 Material Description: Bitumen pad to underside of sink
Building Address:
As Above Survey Report
ASSESSMENT Sample No: 015
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 1 Items
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 1007
Floor: Ground
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Male WC including lobby
Building: ALCO01000562 Material Description: Textured coating to ceiling
Building Address:
As Above Survey Report
ASSESSMENT Sample No: 013
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 15 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 2002
Floor: Mezzanine
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Washer storage
Building: ALCO01000562 Material Description: Red floor tiles with bitumen adhesive
Building Address:
As Above Survey Report
ASSESSMENT Sample No: 016
Asbestos Type: 0 - No asbestos detected Approx Size of Item: 10 m²
Product Type: COMMENTS AND RECOMMENDATIONS:
Extent of Damage: Timescale for Recommendation : No action
Surface Treatment:
Recommendation: No further action required
Priority Risk: N/A
(USVF Bridging Contract)
Area No: 2002
Floor: Mezzanine
Site Address:
AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Washer storage
Building Address:
As Above Survey Report
ASSESSMENT Sample No: AWS - 011
Asbestos Type: 1 - Chrysotile Approx Size of Item: 4 Items
Product Type: 2 - AIB, Millboard, gaskets, paper etc COMMENTS AND RECOMMENDATIONS:
Extent of Damage: 1 - Low damage Timescale for Recommendation : 12 months
Surface Treatment:
1 - Enclosed sprays and lagging, AIB, AC sheets etc Recommendation: Manage
Priority Risk: 4
Normal Occupant Activity:
1 - Low Disturbance
Comments:
Includes flanges to pipework to wall and flanges to heater
Likelihood of Disturbance:
1 - Low Likelihood of Disturbance
Human Exposure Potential:
1 - Low Human Exposure Potential
Maintenance Activity : 1 - Low Risk Maintenance Activity Total Risk Score: 9
Appendix C
DRAWINGS
Date of Survey/Inspection
Survey Reference
Surveyors
Site Address
Client
Not to Scale Beyond Remit of Survey
Inaccessible Areas
Sample Extent
Sample PointKey:
As With Sample = AWS
Sample Presumed = P
Amey Defence Services Ltd (USVF Bridging Contract)
139617-021
AEDY – 562 – Hsg Sup Store F, RAF Alconbury, Huntingdon PE28 4DA
10/06/2021
L Crush & L Dooley
Please ensure these plans are reviewed in context with the scope of works and recorded limitations in the survey report
GROUND FLOOR
P001 Ramp
S012
S011
S008
S001
S007 S014 S015
AWS
S006
S009
S013
10061004
Lift
Ramp
S010
S002
S003 S004 S005
Up
Up Up
Date of Survey/Inspection
Survey Reference
Surveyors
Site Address
Client
Not to Scale Beyond Remit of Survey
Inaccessible Areas
Sample Extent
Sample PointKey:
As With Sample = AWS
Sample Presumed = P
Amey Defence Services Ltd (USVF Bridging Contract)
139617-021
AEDY – 562 – Hsg Sup Store F, RAF Alconbury, Huntingdon PE28 4DA
10/06/2021
L Crush & L Dooley
Please ensure these plans are reviewed in context with the scope of works and recorded limitations in the survey report
MEZZANINE FLOOR
Dn
Lift
Dn
OPEN TO BELOW
OPEN TO BELOW
Dn
AWS
S016
Appendix D
LABORATORY TEST CERTIFICATE(S)
SOCOTEC Asbestos Limited is a wholly owned subsidiary of SOCOTEC, registered in England and Wales, registered company 04951688 at SOCOTEC House, Bretby Business Park, Ashby Road, Burton upon Trent, DE15 0YZ.
Telephone: 01302 724455 E-mail: ecs.doncaster@socotec.com
Client
Contract)
Delivered/Collected Collected
Address 1st Floor, Swales Pavilion, RAF Wyton, Huntington, PE28 2EA Analysis Report No D149638
Attention Andrew Flanagan Report Date 28/Jun/2021
Site Address AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA Site Ref No 139617-021
Date Sample Taken 10/06/2021 Page No 1 of 2
Date Sample Received 16/06/2021 No of Samples 16
Date of Analysis 23/06/2021
SOCOTEC
Asbestos
SAMPLE No
CLIENT
SAMPLE
No
SAMPLE LOCATION & DESCRIPTION* FIBRE TYPE
DETECTED
ANALYSIS No
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-001
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-002
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-003
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-004
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-005
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-006
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-007
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-008
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-009
Ground Floor - Stacks Storage 1001 - Insulating board panels to wall
NADIS 139617-021-001-010
KEY: NADIS - No Asbestos Detected in Sample.
All samples will be retained for a minimum of 6 Months.
Analysed by: Name: Rasoul Rabiei Authorised signatory:
Name: NICOLA BATCHELOR
Position: Laboratory Analyst / Site Analyst
Position: Senior Lab Analyst
BULK005-VER 16 01-March 2019
Samples of material referenced above have been examined using our internal procedure SCI/ASB/007, based on HSE’s HSG248, Asbestos: The Analysts guide for sampling, analysis and clearance procedures. If samples have been DELIVERED, the site address and actual sample location is as given by the client at the time of delivery. SOCOTEC Asbestos Limited is not responsible for the accuracy or competence of the sampling by third parties, and can therefore not be held responsible for any interpretation of the results shown. The inspection report shall not be reproduced except in full without the approval of the inspection body and the client. *Please note that the sample description, material type and comments/observations are opinions and therefore not within the scope of UKAS accreditation.
Askern Road, Carcroft, Doncaster.
DN6 8DG
CERTIFICATE FOR IDENTIFICATION OF
ASBESTOS FIBRES
SOCOTEC Asbestos Limited is a wholly owned subsidiary of SOCOTEC, registered in England and Wales, registered company 04951688 at SOCOTEC House, Bretby Business Park, Ashby Road, Burton upon Trent, DE15 0YZ.
Telephone: 01302 724455 E-mail: ecs.doncaster@socotec.com
Client
Contract)
Delivered/Collected Collected
Address 1st Floor, Swales Pavilion, RAF Wyton, Huntington, PE28 2EA Analysis Report No D149638
Attention Andrew Flanagan Report Date 28/Jun/2021
Site Address AEDY - 562 - Hsg Sup Stor F, RAF Alconbury, Alconbury, Huntingdon, PE28 4DA Site Ref No 139617-021
Date Sample Taken 10/06/2021 Page No 2 of 2
Date Sample Received 16/06/2021 No of Samples 16
Date of Analysis 23/06/2021
SOCOTEC
Asbestos
SAMPLE No
CLIENT
SAMPLE
No
SAMPLE LOCATION & DESCRIPTION* FIBRE TYPE
DETECTED
ANALYSIS No
Ground Floor - Stacks Storage 1001 - Gaskets to horizontal flanges x15
CHRYSOTILE 139617-021-001-011
Ground Floor - Stacks Storage 1001 - Gaskets to vertical flanges x7
NADIS 139617-021-001-012
Ground Floor - Male WC including lobby 1007 -
Textured coating to ceiling
NADIS 139617-021-001-013
014 Ground Floor - Break Room 1004 - Beige floor tiles NADIS 139617-021-001-014
Ground Floor - Break Room 1004 - Bitumen pad to underside of sink
NADIS 139617-021-001-015
Mezzanine Floor - Washer storage 2002 - Red floor tiles with bitumen adhesive
NADIS 139617-021-001-016
KEY: NADIS - No Asbestos Detected in Sample.
All samples will be retained for a minimum of 6 Months.
Analysed by: Name: Rasoul Rabiei Authorised signatory:
Name: NICOLA BATCHELOR
Position: Laboratory Analyst / Site Analyst
Position: Senior Lab Analyst
BULK005-VER 16 01-March 2019
Samples of material referenced above have been examined using our internal procedure SCI/ASB/007, based on HSE’s HSG248, Asbestos: The Analysts guide for sampling, analysis and clearance procedures. If samples have been DELIVERED, the site address and actual sample location is as given by the client at the time of delivery. SOCOTEC Asbestos Limited is not responsible for the accuracy or competence of the sampling by third parties, and can therefore not be held responsible for any interpretation of the results shown. The inspection report shall not be reproduced except in full without the approval of the inspection body and the client. *Please note that the sample description, material type and comments/observations are opinions and therefore not within the scope of UKAS accreditation.
Askern Road, Carcroft, Doncaster.
DN6 8DG
CERTIFICATE FOR IDENTIFICATION OF
ASBESTOS FIBRES
Appendix E
DEFINITIONS AND GUIDANCE NOTES
Your Survey Recommendations
A.1 Recommendations are made based upon each items assessed potential for fibre release as recommended by the guidance published by the Health and Safety Executive.
A.2 Definition of terms for actions detailed within this report:
i. Add to inspection: Provision of a policy of 12 monthly inspections together with procedures, including but not exclusively limited to action should deterioration be observed, as well as training for staff and persons possibly coming into contact with the material.
ii. Manage: Provision of a policy of regular inspection together with procedures, whilst continually monitoring the condition of the material for further deterioration.
iii. Manage & Label: Process and provision for the fixing of labels -standard ‘red A’ label as per Schedule 2 of the Control of Asbestos Regulations (CAR), to the surface of the material to warn of the hazard.
iv. Control/Restrict access: Material in a condition and position that is likely to cause fibre release should it be disturbed. Immediate action to implement procedure to restrict access to area via physical controls.
v. Repair: Addition of a seal to the material to prevent the further deterioration and breakdown of the material. This action should also be carried out with labelling.
vi. Encapsulate: Provision of paint type coating to effect a continuous seal to surface of the material and thereby prevent fibre release.
vii. Remove: Complete removal of the material under controlled conditions so as to comply with CAR.
File details come from the government source that posted it. Updated .