Attachment_4.pdf

PDF 9 MB Posted

Attached to
Repair/Upgrade Kitchen, GOH 4200, Plaza Housing
Solicitation number
FA5270-15-T-0045
Issued by

About this file

Attachment 4

View the file

Other files

File Type Posted
Revised_EVKP14-4269_Blank_AF_Form_3052_23Feb2015.xlsx XLSX spreadsheet
RFI.pdf PDF
Amendment_1.doc DOC document
Attachment_7.pdf PDF
Attachment_5.pdf PDF
Attachment_6.pdf PDF
Attachment_2.pdf PDF
Attachment_3.pdf PDF
Solicitation.pdf PDF
Attachment_1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT 4

PRODUCT DATA/

INSTALLATION

MANUAL

DISHWASHER

DishDrawer® Installation instructions

US CA

WARNING!

Electrical hazard

Before installing the DishDrawer®, remove the house fuse or open the circuit breaker.

If permanently connecting the DishDrawer®, be sure the power is isolated and the DishDrawer® unplugged.

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly grounded.

If the DishDrawer is installed as a permanently connected appliance:

GROUNDING INSTRUCTIONS - This appliance must be connected to a grounded metal, permanent wiring system, or an equipment-groounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box.

Failure to follow this advice may result in electrical shock or death.

DD24D models

Important!

SAVE THESE INSTRUCTIONS

The models shown in this document may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

SAFETY AND WARNINGS

WARNING!

Cut hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

Important safety instructions!

Installation of this DishDrawer® requires basic mechanical and electrical skills.

Be sure to leave these Instructions with the Customer.

Installation must comply with your local building and electricity regulations.

At the completion of the DishDrawer® installation, the Installer must perform

Final Check List.

Remove all packaging materials supplied with the DishDrawer®.

This DishDrawer® is manufactured for indoor use only.

Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations.

The DishDrawer® MUST be installed to allow for future removal from the enclosure if service is required.

The switched power outlet must be outside the DishDrawer® cavity so that it is accessible after installation.

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord.

If the DishDrawer® is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage.

Make sure only new hoses are used for connection (supplied with DishDrawer®). Old hoses should not be reused.

Failure to install the DishDrawer® correctly could invalidate any warranty or liability claims.

If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product.

(1,1) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM(1,1) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM http://www.appliancesconnection.com/

2 3PRODUCT DIMENSIONS CABINETRY DIMENSIONS

N

BC

E

D

F

J

G

H

M I

Installation diagrams for illustration purposes only

K

L

A

MG

C

I

Product dimensions (inches (mm))

Prefi nished

LCD

D

24D

Prefi nished Flat door

D

24D

Integrated

D 24D

A overall height* of product 32 ¼ - 34 5⁄8” (819.5- 879.5)

32 ¼ - 34 5⁄8” (819.5- 879.5)

32 ¼ - 34 5⁄8” (819.5- 879.5)

B overall width of product 23 9⁄16”(599) 23 9⁄16”(599) 23 9⁄16”(599)

C overall depth of product (excl. curvature/handle) 22 7⁄16” (570) 22 7⁄16” (570) 22 7⁄16” (570)

D depth of drawer (open) (excl. curvature/handle) 21 3⁄16” (538) 21 3⁄16” (538) 21 3⁄16” (538)

E height* of chassis 31 7⁄8” (809) 31 7⁄8” (809) 31 7⁄8” (809)

F height range of levelling feet 2 3⁄8” (60) 2 3⁄8” (60) 2 3⁄8” (60)

G depth of chassis (incl. trimseal) 21 ¾ ” (552) 21 ¾ ” (552) 21 ¾ ” (552)

H depth of drawer front panel (excl. curvature/handle) 11⁄16” (18) 11⁄16” (18) 11⁄16” (18)

I depth of curvature or handle 7⁄16” (11) 1 5⁄8” (41) n/a

J depth of toekick 2 - 4 5⁄16” (50 - 110) 2 - 4 5⁄16” (50 - 110) 2 5⁄8 - 5”(67 - 127)**

K height of upper drawer front 15 ½ ” (394) 15 11⁄16” (398) 15 11⁄16” (398) min

L height of lower drawer front 14” (356) 14” (356) 12 ¼ ” (311.5) min

M height of installation bracket slots (on top of chassis) 1⁄16” (2) 1⁄16” (2) 1⁄16” (2)

N height of drawer fronts 29 9⁄16” (751) 30 1⁄16” (764) 28 ¼ ” (717.5) min

* Chassis heights include bracket slots

** less the Toekick Panel thickness (Minimum Panel thickness using the supplied screws is 3⁄8” (9 mm)).

Note: for Prefi nished Flat door models, height from top of handle to top of drawer - 2 ½ ” (64 mm).

Cabinetry dimensions (inches (mm))

Prefi nished

LCD

24D

Prefi nished Flat door

D

24D

Integrated

D 24D

A inside height of cavity 32 5⁄16 - 34 ¾ ” (820- 882.5)

32 5⁄16 - 34 ¾ ” (820- 882.5)

32 5⁄16 - 34 ¾ ” (820- 882.5)

B inside width of cavity 23 5⁄8” (600) 23 5⁄8” (600) 23 5⁄8” (600)

C inside depth of cavity (inside) 22 7⁄8” (580) 22 7⁄8” (580) 22 7⁄8” (580)

D height of adjacent cabinetry 30” (762) 30” (762) min. 28 3⁄8” (720)

E height of toekick space 3 15⁄16 - 6 5⁄16” (100-160) 3 15⁄16 - 6 5⁄16” (100-160) 3 15⁄16 - 6 5⁄16” (100-160)

Minimum clearances (inches (mm))

1⁄8” (2.5 mm)

1⁄8” (2.5 mm)

A

B

C

D

E

Installation diagrams for illustration purposes only

½ ” (13 mm)

(1,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM(1,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM

PARTS SUPPLIED

Clamp (1)Wire clip (2) Phillips 16 mm screws (9)

Drain hose support (1)

Moisture protection tape (1) (to prevent moisture damage)

Drain hose joiner (1)

Top mounting brackets (2)

Prefinished toekick (1) white or black

Washer (1) Edge protector (1) (if services hole partition is metal)

Hexagonal socket (2) (long & short)

2” x 4”

If the Drain hose(s) supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hose(s) by 11’ 10” (3.6 m). The kit is available from the nearest Fisher & Paykel Authorized Service Agent, or Toll free 1.888.936.7872 or www.fisherpaykel.com.

Important!

Be sure the edges of the services hole are smooth or covered. If the services hole is through a metal partition the hole must be protected with the Edge protector supplied to prevent damage to the power cord or hoses.

These marks indicate mounting bracket screw locations Preferred position. If adequate clearance, services hole can be higher to clear toekick space.

If hole is higher, ensure drain hose(s) are routed straight into the waste connection.

Water Connection Recommended HOT (Maximum 140°F/60°C).

Supplied hose to suit 3/8” (9 mm) male compression fitting.

110-120 VAC

max. 15 A

Note: Services can be located either side of DishDrawer®.

max. ø 1 ½ ” (38 mm) min. 7 7⁄8” (200 mm)

3⁄8” (10 mm) max. 17 11⁄16” (450 mm)

If no side partition, use a brace for securing.

Moisture protection tape must be applied.

CAVITY PREPARATION5

Water Pressure Max Min Water softener models 1 MPa (145 psi) 0.1 MPa (14.5 psi) Other models 1 MPa (145 psi) 0.03 MPa (4.3 psi)

Drains will need to be separated to satisfy kosher requirements. We suggest you confirm acceptability with your local rabbi in respect to kosher installations.

Max. distance of hoses and cord from chassis edge

Left hand side

Right hand side

Drain hose 78 ½ ” (2000 mm)

70 ½ ” (1800 mm)

Inlet hose 64 ¾ ” (1650 mm)

49” (1250 mm)

Power cord (excl. plug) 29 ½ ” (750 mm)

27 ½ ” (700 mm)

Left hand side

Right hand side

Water supply

(2,1) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM(2,1) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM

30 mm

A

Ensure the drawer is removed and then rotated counter-clockwise to prevent kinked hoses.

Access cover

Remove the access cover

Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.

Ensure the drawer clips on both sides are reset.

Ensure the drawer is now rotated clockwise back.

Remove knock-out for cable clamp. Fit suitable cable clamp for the conduit and terminate the wiring as shown.

Use copper conductors only.

5 7⁄8” (150 mm)

C D

Remove Power supply

B

OPTIONALLY HARD WIRING THE PRODUCT6

(2,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM(2,2) -1- 599618C DD24D install A2 USCA.indd 15/4/09 10:01:39 AM x 4

1 2 34

Tie together to avoid kinking.

Ensure product is level and aligning with cabinetry. Using the most appropriate length Hexagonal socket supplied, fully extend levelling feet up to required distance by hand.

Hexagonal socket

A A

B

ROUTE THE HOSES AND MOVE INTO THE CAVITY7

REMOVE THE DRAWER AND LEVEL THE PRODUCT8

optionaloptional (x2)

Ensure hoses and cord are not kinked or twisted.

B

30 mm

5 ” (150 mm)

Ensure the drawer is removed and then rotated counter-clockwise to prevent kinked hoses.

5 7⁄8” (150 mm)

A

OR Loosen feet only and take care when pushing the product into the cavity that you do not bend the feet.

If top mounting brackets are being used, ensure they’re securely fitted before sliding product into cavity.

(1,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM(1,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM

B

A

C C

BB

A

A optional max. ¾ ” (19 mm)

4 5 6 7

8 9

Important!

D o not overtighten screw.

SECURE THE PRODUCT AND REFIT THE DRAWER9

A

B

FIT THE TOEKICK10

Before refitting the drawer, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward.

Ensure the drawer clips on both sides are reset.

Ensure the drawer is now rotated clockwise back.

B The product has three pairs of mounting brackets: a pair of optional brackets on the top (C) and two pairs of formed brackets in the side of the chassis (A,B). Use at least two out of the three pairs to secure the product.

Ensure the sound insulation is repositioned correctly.

Where the toekick meets the bottom of the tub is the cut-off point

(1,2) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM(1,2) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM

PLUMBING AND DRAINAGE OPTIONS11

29 ½” - 34 ¾” (750 -

882.5 mm)

1 ½” (38 mm) max. 4 ¾” (120 mm)

29 ½” - 34 ¾” (750 -

882.5 mm)

A

If space is limited for fixing, push hose through drain hose support to required height

DishDrawer® with Waste Disposal

½

- 3

¾

(7

2.

m m min. R 8 ” (200 mm)

Supplied drain hose joiner (ø ¾ ” (19 mm)) waste tee)

HIGHLOOP

min. 6” (150 mm)

DishDrawer® using Air Break with Drain Hose Joiner

Supplied drain hose joiner (ø ¾ ” (19 mm)) waste tee)

Air Break

37 3⁄8” (950 mm) Max. height to top of Air Break (countertop or wall mounted)

Fit supplied washer

Ensure hoses are routed straight to joiner. Remove excess hose material if necessary.

DishDrawer® and Standpipe Ø 1 1/2” (38 mm)

½

- 3

¾

(7

2.

m m min. R 8 ” (200 mm)

Waste Disposal (optional)

B

Fit supplied washer

180o 180o 180o

Ensure hoses are routed straight to joiner. Remove excess hose material if necessary.

Fit supplied washer

C

If space is limited for fixing, push hose through drain hose support to required height

(2,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM(2,1) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM

FINAL CHECKLIST12 TROUBLESHOOTING13

Check all parts are installed.

Ensure product is level, securely fastened to the cabinetry and opens and closes freely. The DishDrawer® must be free to fully close with no resistance from the cabinetry.

Ensure inlet hose to water supply has rubber washer fitted and is tightened a further half turn after seal contact.

Ensure any knockouts or plugs in drain connection have been drilled out and drain connection has been made.

The drain hose joiner must not support the weight of excess hoses. Keep hoses as fully extended as possible to prevent sagging. Any excess length of hose should be kept on the dishwasher side of the high loop.

If using Plumbing and Drainage OPTION A, ensure the Highloop is a minimum 6” (150 mm) higher than the drain hose joiner.

Turn on the power and water supply. Then press the Power ( ) button to turn the DishDrawer® on. The DishDrawer® should beep and Wash Programme lights light up.

Check the spray arm is in place and free to rotate.

Add three cups of water into the DishDrawer®. On the Wash Programme Selector Panel press Rinse and close the drawer(s). Start the programme by pressing the Start/Pause ( ) button.

After the Rinse programme has finished, ensure machine has run and drained correctly.

Check water supply and drainage connection for leakage.

Repeat for each drawer.

Spray arm

Excessive water remaining above the filter plate, after the rinse cycle Check for kinked drain hoses or blocked waste connection, high loop not properly installed or drain hoses not routed correctly.

No water supply ( shows on display-models with LCD only)

Check water is connected, turned on and the spray arm(s) are correctly fitted and free to rotate.

No lights come on when the drawer is opened Ensure power is connected and is switched on. Check if Auto Power option is on.

Water around water supply and drainage connections

Check connections, existing plumbing and hoses for leaks. Check washer and hose clamps are correctly fitted.

If product is tipping Ensure the product is secured to the cabinetry.

If front panels are misaligned

Check and relevel product. Check the cabinetry is square.

Drawer(s) don’t close properly

Ensure nothing is obstructing the drawer(s) from closing properly eg sound insulation, hoses or drawer latches.

If a problem occurs, consult the Troubleshooting section of the User Guide.

If after checking these points you still need assistance, please refer to the

Service & Warranty book for warranty details and your nearest Authorized Service Centre, or contact us through our website, www.fisherpaykel.com.

www.fisherpaykel.com www.fisherpaykel.ca 599618C US CA 04.09

(2,2) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM(2,2) -2- 599618C DD24D install A2 USCA.indd 15/4/09 10:02:23 AM

OVER THE

RANGE

MICROWAVE

COOKTOP

DOUBLE WALL

OVEN

REFRIGERATOR

For answers to your Monogram,® Cafe™ Series, Porfile™ Series or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.

Dimensions and Installation Information (in inches)

Specification Revised 9/14

A B C

O ve ra ll

D im en si on s

Height to top of hinge (in.) B

Height to top of case (in.) C

Case depth without door (in.) D

Case depth less door handle (in.) E

Case depth with door handle (in.) F

Depth with fresh food door open 90˚ (in.) G

Width (in.) H

Width with door open 90 ̊inc. door handle (in.) I Ai r

Each side (in.)

Top (in.)

Back (in.)

Height to top of crown (in.) A

H

E D

G F

I

69-7/8

29-3/8

35-1/4

36-1/4

48-3/8

35-3/4

44-5/8

1/8

70-1/2

A B C

O ve ra ll

D im en si on s

Height to top of hinge (in.) B

Height to top of case (in.) C

Case depth without door (in.) D

Case depth less door handle (in.) E

Case depth with door handle (in.) F

Depth with fresh food door open 90˚ (in.) G

Width (in.) H

Width with door open 90 ̊inc. door handle (in.) I

Ai r

Each side (in.)

Top (in.)

Back (in.)

Height to top of crown (in.) A

H

E D

G F

I

69-7/8

29-3/8

35-1/4

36-1/4

48-3/8

35-3/4

44-5/8

1/8

70-1/2

PFE29PSD

GE Profile™ Series 28.6 Cu. Ft. French-Door Refrigerator

Listed by Underwriters Laboratories

Specification Revised 9/14

Features and Benefits

• Hands-free Autofill - Lets you walk away while the dispenser automatically fills any container with filtered water

• Precise Fill setting - Dispenses filtered water in accurate measurements for easy food and drink preparation

• Full-width electronic temperature-controlled drawer with LED lights - 5 accurate settings deliver the optimal temperatures for keeping foods fresh

• TwinChill™ evaporators - Separate climates in the fresh food and freezer sections help keep foods fresh

• Color LCD screen with photo upload - Add a personal touch when you upload photos to the color LCD display from your flash drive

• Showcase LED lighting - Positioned throughout the interior and under fresh food doors to spotlight foods inside the refrigerator and in the freezer

• Seamless stainless steel dispenser with pullout tray - Gives you a streamlined look while easily filling tall items

• Space saving icemaker - Located on the door with integrated bins to create more usable storage space

• Drop-down tray - Allows for extra door storage when you need it and tucks away when you don’t

• In-the-door filter - Located in the door for more available space in the fresh food section and easy replacement

• Advanced water filtration uses RPWF replacement filter - Removes trace pharmaceuticals from water and ice

• Model PFE29PSDSS - Stainless steel

PFE29PSD

GE Profile™ Series 28.6 Cu. Ft. French-Door Refrigerator

DISPOSER, SINK AND

FAUCET

Our Badger 5XP® model provides more power and a longer warranty than the Badger® 5 or Badger® 1.

This model also offers the following features and benefits:

• 3/4 Horsepower Heavy Duty Motor (Quiet Dura-Drive® Induction Motor)

• 3-Year We Come To You® In-Home Parts And Labor Service Warranty

• Rugged Galvanized Steel Construction (For Disposer Durability)

• Space-Saving Compact Design

Submittal Sheet

Job Specifications

Specifications Type of Feed Continuous

On/Off Control Wall Switch

Motor Single Phase

HP 3/4

Volts 120

HZ 60

RPM 1725

Amp. (Avg. Load) 9.5

Time Rating Intermittent

Lubrication Permanently Lubricated Upper & Lower Bearings

Shipping Weight (Approx.) 15 lbs. 2 oz.

Unit Finish Waterborne Grey Enamel

Overall Height 12-5/8”

Grind Chamber Capacity 26 oz.

Motor Manual Reset Protection Overload

Average Approx. 1 Gallon per Water Usage Person Per Day

Average Electrical Usage 3-4 KWh per Year

Drain 1-1/2” Cushioned Connection Slip Joint

Dishwasher Drain Connection Yes

Food Waste Disposers

Dimensions

Food Waste Disposer(s) shall be InSinkErator Badger 5XP®, continuous feed, with 3/4 H.P. motor, galvanized steel grinding elements with two stainless steel 360° swivel lugs.

Self-service wrench.

Warranty:

3- Year parts and in-home service.

Sample Specification

The complete InSinkErator warranty is included in the Care & Use Booklet packed with each unit.

* Distance from bottom of sink to center line of disposer outlet.

Add 1/2" when stainless steel sinks are used.

** Length of tailpipe from center line of disposer outlet to end of tailpipe.

NOTE: Plumb waste line to prevent standing water in disposer motor housing.

1-800-558-5700 www.insinkerator.com

4"

Dishwasher Drain

Connection

5"

6"

125/8"

65/16"

The Emerson logo is a trademark and service mark of Emerson Electric Co. The mounting collar configuration is a trademark of Emerson Electric Co.

InSinkErator may make improvements and/or changes in the specifications at any time, in its sole discretion, without notice or obligation and further reserves the right to change or discontinue models.

H715-10L-02-02 Printed in U.S.A. © 2010 InSinkErator, InSinkErator is a division of Emerson Electric Co. All Rights Reserved.

Food waste disposers can provide an environmentally responsible alternative to transporting food waste to landfills. And they can help reduce greenhouse gas emissions. At capable wastewater treatment plants, food waste can be recycled to produce renewable energy. Additionally, capable wastewater treatment plants can process food waste into fertilizer. (Check the plant in your area.)

Model ELUH3220PD

SPECIFICATIONS

GENERAL

Highest quality sink formed of #18 (1.2mm) gauge, type 304 (18-8) nickel bearing stainless steel with Perfect Drain. Undermount.

OPTIONAL ACCESSORIES

Bottom Grid: LKWOBG1418SS Cutting Boards: CBR1418, CBS1418

Rinsing Baskets: LKWRB1418SS, LKWERBSS Utensil Caddy for Rinsing Basket: LKWUCSS

Mounting Clip: LKUCLIP8 (2 packages required)

DESIGN FEATURES

Bowl Depth: See chart on next page.

Coved Corners: 1-3/4" (44mm) vertical and horizontal radius.

Highlighted Satin finish.

Finish: Exposed surfaces are hand blended to a Lustrous

Gourmet Undermount Sink

Model ELUH3220PD and ELUH322010PD with Perfect Drain TM

Countertop

Silicone Caulk (Not Furnished)

Sink

1/8 (3mm) (Approx.)

Overhang1-3/8"

(35mm)

Mounting Clip: LKUCLP8 (Not Furnished)

Fastener (Not Furnished)

Installation Profile 1/8" (3mm) Overhang (ELU Sink)

Designed to affix to the underside of any solid surface countertop.

NOTE: All Elkay undermount sinks are designed to affix to the underside of any solid surface countertop.

Underside: Fully protected by to reduce condensation and dampen sound.

Sound Guard ® undercoating

OTHER

Drain opening: 3-3/8" (86mm)

Waste Fitting complies with ASME A112.18.2/CAN/CSA-B125.2

Perfect Drain: Seamlessly welded stainless steel collar eliminates the gap between a traditional drain and the sink for a sanitary and gap free installation.

Each sink shipped with two LKPD1 drain kits, or a garbage disposer can be installed on either sink bowl for user convenience.

Patent Pending

Sink with Drain Kit Installed

7-9/16" (192mm)

3-1/2" (89mm)Installation Profile

1/2"(13mm) Reveal

Countertop Silicone Caulk (Not Furnished)

1/2" (13mm)

Sink1-1/8" (29mm)

Mounting Clip: LKUCLIP8 (Not Furnished) Fastener

(Not Furnished)

C

Sinks are listed by IAPMO as meeting the applicable requirements of the Uniform Plumbing Code , International Plumbing Code , and National Plumbing Code of Canada.

Sink complies with ASME A112.19.3/ CSA B45.4

In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets.

This specification describes an Elkay product with design, quality, and functional benefits to the user. When making a comparison of others producers offerings, be certain these featrues are not overlooked.

Elkay 2222 Camden Court Oak Brook, IL 60523

© 2014 Elkay (Rev. 05/14) 1-419elkay.com

Elkay® Perfect Drain™ sinks are designed and approved for compatible disposers manufactured by InSinkErator® utilizing the Quick Lock® mounting con�guration. Use of non-approved disposers may void Elkay warranty.

InSinkErator, Quick Lock and the mounting collar con�guration are trademarks of Emerson Electric Co.

Model Overall Inside Each Bowl Number L W L W DD

ELUH3220PD 31-1/4

(794mm)

(508mm)

(356mm)

(457mm)

7-7/8 (200mm)

(914mm)

ELUH322010PD 9-7/8

(251mm)

9-3/8 (238mm)

11-3/8 (289mm)

(914mm)

SINK DIMENSIONS*

**Template (# 74180287) is packed with every sink.

*Length is left to right. Width is front to back.

Cutout in Countertop

Minimum Cabinet

Size

(356mm)

(457mm)

See Template**31-1/4

(794mm)

(508mm)

B

DETAIL A

1/8" OVERHANG INSTALLATION

SINK FLANGE

CABINET

WALL

COUNTER-TOP

CUT OUT

PROVIDED BY TEMPLATE

1/2" 13mm

38mm

FAUCET HOLE1-1/2"

2-1/4" 57mm

A

COUNTER-TOP

CUT OUT

PROVIDED BY TEMPLATE

SINK FLANGE

1/2" REVEAL INSTALLATION

DETAIL B

CABINET

WALL

1/2" 13mm

38mm

FAUCET HOLE1-1/2"

2-1/4" 57mm

ELUH3220 Illustrated ELUH322010 Illustrated

SPECIFICATIONS Model ELUH3220PD and ELUH322010PD with Perfect Drain TM

3-3/4" (95mm)

5" (127mm)

20" (508mm)

18" (457mm)

14" (356mm)

14" (356mm)

31-1/4" (794mm)

15-1/4" (387mm)

9-7/8 (251mm) 11-3/8

(289mm) 1-3/4" R (44mm)

1-3/4" R (44mm)

1-3/4" R (44mm)

7-7/8 (201mm) 9-3/8

(238mm)

15-1/4" (387mm)

3-3/4" (95mm)

5" (127mm)

20" (508mm)

18" (457mm)

14" (356mm)

14" (356mm)

31-1/4" (794mm)

1-3/4" R (44mm)

Gourmet Undermount Sink

In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. Please visit elkay.com for the most current version of Elkay product specification sheets.

This specification describes an Elkay product with design, quality, and functional benefits to the user. When making a comparison of others producers offerings, be certain these featrues are not overlooked.

Elkay 2222 Camden Court Oak Brook, IL 60523

© 2014 Elkay (Rev. 05/14) 1-419elkay.com

File details come from the government source that posted it. Updated .