Fire Alarm Tests - 2022.pdf
PDF 672 KB Posted
- Attached to
- Fire Alarm System Testing and Maintenance Federal contract opportunity
- Solicitation number
- FA521524Q0011
About this file
This document is a Combined Synopsis/Solicitation for a Request for Quotations (RFQ) for fire alarm system testing and maintenance services. The Department of the Air Force Pacific Air Forces is seeking quotes from small business vendors for this requirement under NAICS code 561621. Responses and questions must be submitted electronically by the due dates of August 28, 2024 and August 30, 2024, respectively. This acquisition will utilize simplified acquisition procedures and is a 100% Small Business Set-Aside. The solicitation incorporates the FAR provisions and clauses in effect through Federal Acquisition Circular 2024-05.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| FA521524Q0011 QA_16Sep2024.pdf | ||
| B13and19 KaenaPoint AsBuilt_Fire.pdf | ||
| Dwg No. E-97-96 - Sheet 16 - Demolition and New Fire Alarm Plans Bldg 41.pdf | ||
| Fire Alarm Panels.pdf | ||
| Bldg 41 Kaena Pt - Mech Partial Fire.pdf | ||
| Dwg No. E-97-96 - Sheet 7 - New Duct Detector and Sprinkler Flow Bldg 41.pdf | ||
| Combined Synopsis FA521524Q0011_Amendment 3.pdf | ||
| Fire Alarm Drawings.pdf | ||
| Fire Alarm Drawings 2.pdf | ||
| Combined Synopsis FA521524Q0011_Amendment 2.pdf | ||
| Combined Synopsis FA521524Q0011_Amendment 1.pdf | ||
| FA521524Q0011 QA_29Aug2024.pdf | ||
| Kaena Point - Fire System Components.xlsx | XLSX spreadsheet | |
| Combined Synopsis FA521524Q0011 signed.pdf | ||
| SOW_Fire Protection System Maintenance_1JUL2024.pdf | ||
| SOW Attachment - KPSTS Map and Buildings.pdf |
Show all 16
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fire Alarm & Life Safety Inspection and Testing Report
Date: 09/19/2022
Time: 8:00:00 AM
Service Organization Property Name (User)
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B10
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Hwy, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: Leeroy Wymer
License No: 220247 Telephone: (907) 854-3770
Telephone: (808) 682-1000
Monitoring Entity Approving Agency
Contact: Civil Engineer Operations Contact: N/A
Telephone: (808) 697-4316 Telephone: N/A
Monitoring Account Ref. No: N/A
Type of Transmission Service
Communicator: N/A Weekly
Manufacturer: N/A Monthly
Model Number: N/A Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: Edwards Model No: EST3
Circuit Styles: B, B
Number of Circuits: 9
Software Revision: V5.32
Last Date System Had Any Service Performed: 09/19/2022
Last Date that Any Software or Configuration Was Revised: 09/19/2022
ALARM INITIATING DEVICES AND CIRCUIT INFORMATION
Quantity Circuit Style Device Types
2 B Heat Detector, Edwards
2 B Pull Station, Radionics
1 B Smoke Detector, Edwards
Alarm Verification feature is disabled X enabled
ALARM NOTIFICATION APPLIANCES AND CIRCUIT INFORMATION
Quantity Circuit Style Appliances
1 B Bell
38 B Horn/Strobe, Edwards
No. of alarm notification appliance circuits: 8
Are circuits monitored for integrity? Yes No
SUPERVISORY SIGNAL INITIATING DEVICES AND CIRCUIT INFORMATION
Quantity Circuit Style Devices
N/A N/A N/A
SIGNALING LINE CIRCUITS
Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1)
Quantity B Style(s)
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): Mechanical Room 110
Disconnecting Means Location: FP Panel Breaker #1
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 51Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Location of fuel storage: N/A
TYPE BATTERY
Battery Type Manufacturer Model Number Voltage Amps
Sealed Lead Acid Power-Sonic PS-1270 12 7
Sealed Lead Acid Power-Sonic PS-1270 12 7
Sealed Lead Acid Power-Sonic PS-1270 12 7
Sealed Lead Acid Leoch DJM1250 12 51
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Emergency system described in NFPA 70, Article 700
Legally required standby described in NFPA 70, Article 701
Optional standby system described in NFPA 70, Article 702, which also meets the performance requirements of Article 700 or 701
PRIOR TO ANY TESTING
NOTIFICATIONS ARE MADE Yes No Who Time
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment Pass
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
TYPE Visual Functional Comments
Battery Condition
Pass
Load Voltage
Discharge Test
N/A
Charger Test
Specific Gravity
TRANSIENT SUPPRESSORS
REMOTE ANNUNCIATORS N/A
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Speakers N/A
Voice Clarity
INITIATING AND SUPERVISORY DEVICES TESTS AND INSPECTIONS
Location & S/N Device Type
Visual Check
Functional Test
Factory Setting
Measured Setting Pass Fail
2nd fl room 111 across restroom Heat Detector
2nd fl room 111 in restroom Heat Detector
1st fl main entrance lobby Pull Station
2nd fl main entrance lobby Pull Station
2nd fl hallway in closet above panel Smoke Detector
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Comments: N/A
EMERGENCY COMMUNICATIONS EQUIPMENT Visual Functional Comments
Phone Set N/A
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Call-in Signal N/A
System Performance N/A
INTERFACE EQUIPMENT Visual
Device Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Supervisory Signal N/A N/A
Supervisory Restoration N/A N/A
NOTIFICATION THAT TESTING IS COMPLETE Yes No Who Time
Building Management Leeroy 4:00P
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Other (Specify) N/A N/A
The following did not operate correctly: N/A
System restored to normal operation: Pass Date: 09/19/2022 Time: 4:00:00 PM
THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS.
Name of Inspector: Alston Chamizo Date: Time:
Signature:
Name of Owner or Representative: Leeroy Wymer Date: Time:
Signature:
DESCRIPTION:
CALL TYPE:
WORK PERFORMED: 09/19/2022
D. IJima C. Yoshino
8 Hours Each
ACTIONS TAKEN:
Building 10:
-Test and inspected the following devices:
1 Control Panel 3 Expander Panel 4 Batteries 1 Smoke Detectors 2 Heat Detectors 2 Pull Station 38 Horn/Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-All devices passed test and inspection.
FOLLOW UP ACTIONS:
-No follow up actions necessary.
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220247-1
DATE: 09/21/2022
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B10 2022 FA T&I
9 - MAINTENANCE
IS JOB COMPLETE? No DISC/CREDIT: $0.00
SALES TAX: $0.00
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/20/2022 11:31AM
Employee: Alston Chamizo Date: 09/20/2022 11:31AM
TERMS AND CONDITIONS
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts remainig unpaid after the due date, plus attorney's fees if collection proceedings are instituted.
Date: 08/25/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B8
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: LeeRoy Wymer
License No: 220198 Telephone: (907) 854-3770
Communicator: N/A Weekly
Manufacturer: N/A Monthly
Model Number: N/A Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: N/A Model No: N/A
Circuit Styles: B, B
Number of Circuits: 2
Software Revision: N/A
Last Date System Had Any Service Performed: N/A
Last Date that Any Software or Configuration Was Revised: N/A
1 B Duct Detector, Edwards
4 B Heat Detector, Edwards
1 B Pull Station, Radionics
1 B Horn/Strobe, Edwards
No. of alarm notification appliance circuits: 1
SIGNALING LINE CIRCUITS
Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1)
Quantity 1 Style(s) B
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage N/A Amps N/A
Overcurrent Protection: N/A Amps N/A
Location (of Primary Supply Panelboard): N/A
Disconnecting Means Location: N/A
(b) Secondary (Standby): N/A Storage Battery: Amp-Hr Rating N/A
Calculated capacity to operate system, in hours: N/A 24 N/A 60
Engine-driven generator dedicated to fire alarm system: N/A
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit N/A
Interface Equipment Pass
Lamps/LEDS N/A
Fuses N/A
Primary Power Supply N/A
Trouble Signals N/A
Disconnect Switches N/A
Ground Fault Monitoring N/A
SECONDARY POWER
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Left of AHU Duct Detector
Left Front Heat Detector
Left Rear Heat Detector
Right Front Heat Detector
Right Rear Heat Detector
Check
Functional Test
Factory Setting
Measured
Entrance Pull Station
Comments: Building fire alarm system is controlled by the FACP in building 10. Will apply pass sticker to building 10.
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Other (Specify) N/A N/A
The following did not operate correctly: N/A
System restored to normal operation: Pass Date: 08/25/2022 Time: 4:00:00 PM
THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS.
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 08/25/2022
A. Chamizo D. Ijima
2 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
1 Duct Detector 4 Heat Detector 1 Pull Station 1 Horn/Strobe
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-All devices passed test and inspection.
-This FACP is located in building 10 and will be stickered for building 8 when tested.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220198-1
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B8 2022 FA T&I
10 - SERVICE
IS JOB COMPLETE? No DISC/CREDIT: $0.00
SALES TAX: $0.00
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/02/2022 09:10 AM
Date: 09/02/2022 09:10 AM
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 08/26/2022
Time: 11:50:02 AM
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B9
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: LeeRoy Wymer
License No: Telephone: 9078543770
Telephone: 8086821000
Contact: Contact:
Telephone: Telephone:
Monitoring Account Ref. No:
Communicator: Weekly
Manufacturer: Monthly
Model Number: Quarterly
Communicator: Semiannually
Manufacturer: Annually
Model Number: Other (Specify)
Control Unit Manufacturer: Model No:
Circuit Styles:
Number of Circuits:
Software Revision:
Last Date System Had Any Service Performed:
Last Date that Any Software or Configuration Was Revised:
Duct Detector, Edwards
Heat Detector, Edwards
Pull Station, Radionics
Alarm Verification feature is disabled enabled
Horn/Strobe, Radionics
No. of alarm notification appliance circuits:
SIGNALING LINE CIRCUITS
Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1)
Quantity Style(s)
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage Amps
Overcurrent Protection: Amps
Location (of Primary Supply Panelboard):
Disconnecting Means Location:
(b) Secondary (Standby): Storage Battery: Amp-Hr Rating
Calculated capacity to operate system, in hours: 24 60
Engine-driven generator dedicated to fire alarm system:
Location of fuel storage:
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity
Building Occupants
Building Management
Other (Specify)
AHJ Notified of Any Impairments
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit
Interface Equipment
Lamps/LEDS
Fuses
Primary Power Supply
Trouble Signals
Disconnect Switches
Ground Fault Monitoring
SECONDARY POWER
REMOTE ANNUNCIATORS
NOTIFICATION APPLIANCES
Audible
Visible
Speakers
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Left Wall Duct Detector
Front Left of Entrance Heat Detector
Front Right of Entrance Heat Detector
Rear Left of Entrance Heat Detector
Rear Right of Entrance Heat Detector
Check
Functional Test
Factory Setting
Measured
Main Entrance Pull Station
Comments:
Phone Set
Phone Jacks
Off-Hook Indicator
Amplifier(s)
Type Generator(s)
Call-in Signal
System Performance
Operation
Simulated Operation Time & Date
SPECIAL HAZARD SYSTEMS
Special Procedures:
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal
Alarm Restoration
Trouble Signal
Supervisory Signal
Supervisory Restoration
Building Management
Monitoring Agency
Building Occupants
Other (Specify)
The following did not operate correctly:
System restored to normal operation: Date: 08/26/2022 Time: 11:50:02 AM
THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS.
Name of Inspector: Alston Chamizo Date: Time:
Signature:
Name of Owner or Representative: LeeRoy Wymer Date: Time:
WORK PERFORMED: 08/26/2022
A. Chamizo D. Ijima
2 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
1 Duct Detector 4 Heat Detector 1 Pull Station 1 Horn/Strobe
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-All devices passed test and inspection.
-This FACP is located in building 39009 and will be stickered for building 9 when tested.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220197-1
DATE: 09/13/2022
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B9 2022 FA T&I
10 - SERVICE
IS JOB COMPLETE? No DISC/CREDIT: $0.00
SALES TAX: $0.00
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/13/2022 12:01 PM
Date: 09/02/2022 09:25AM
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 09/01/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B13
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: Leeroy Wymer
License No: 220196 Telephone: (907) 854-3770
Communicator: Radio Weekly
Manufacturer: King Fisher Monthly
Model Number: Star Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: Simplex Model No: 4010ES
Circuit Styles: A, A
Number of Circuits: 3
Software Revision: N/A
Last Date System Had Any Service Performed: 09/01/2022
Last Date that Any Software or Configuration Was Revised: 09/01/2022
1 A Duct Detector
4 A Pull Station, Simplex
1 A Smoke Detector, Simplex
1 A Waterflow Switch, Simplex
11 A Horn/Strobe, Simplex
3 A Strobe, Simplex
No. of alarm notification appliance circuits: 2
1 A Tamper Switch, Simplex
Quantity 1 Style(s) A
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): Workroom
Disconnecting Means Location: Panel 2DP, Ckt#9
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 33Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Location of fuel storage:
Sealed Lead Acid First Power LFP1233 12V 33Ah
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment Pass
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
Fail
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Workroom AHU Duct Detector
Loading Dock Exit Pull Station
Main Entrance Near FACP Pull Station
Warehouse Near Dropdown Door Pull Station
Warehouse Near Exit Ramp Pull Station
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Main Entrance Above FACP Smoke Detector
Exterior Riser Closet Waterflow Switch
Exterior Riser Closet Tamper Switch
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Other (Specify) N/A N/A
The following did not operate correctly:
Device Type Location Manufacturer Model Comment
Battery Main Entrance FACP First Power LFP1233 Failed load test
System restored to normal operation: Fail Date: 09/01/2022 Time: 4:00:00 PM
THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA STANDARDS.
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 09/01/2022
A. Chamizo D. Ijima
5 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
1 Control Panel 2 Batteries 1 Smoke Detectors 1 Duct Detector 4 Pull Stations 1 Waterflow 1 Tampers 11 Horn/Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-Batteries for FACP failed load test and will need to be replaced.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
MATERIALS NEEDED:
-(2x) 12V 33Ah Batteries
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220196-1
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B13 2022 FA T&I
10 - SERVICE
IS JOB COMPLETE? No DISC/CREDIT: $0.00
SALES TAX: $0.00
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/02/2022 09:33 AM
Employee: Alston Chamizo Date: 09/02/2022 09:33 AM
TERMS AND CONDITIONS
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 09/06/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B19
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: Leeroy Wymer
License No: 220202 Telephone: (907) 854-3770
Telephone: (808) 682-1000 Telephone: N/A
Manufacturer: King Fisher Monthly
Model Number: Star Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: Simplex Model No: 4101ES
Circuit Styles: A, A
Number of Circuits: 3
Software Revision: n/a
Last Date System Had Any Service Performed: 09/06/2022
Last Date that Any Software or Configuration Was Revised: 09/06/2022
2 A Pull Station, Simplex
2 A Smoke Detector, Simplex
1 A Waterflow Switch, Simplex
8 A Horn/Strobe, Simplex
2 A Strobe, Simplex
No. of alarm notification appliance circuits: 2
1 A Tamper Switch, Simplex
Quantity 1 Style(s) A
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): Next to FACP
Disconnecting Means Location: Dedicated breaker
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 50Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Sealed Lead Acid First Power LFP1250 12V 50Ah
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment N/A
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Lobby Exit Near Storage Pull Station
Lobby Near Main Entrance Pull Station
Lobby Above Annunciator Smoke Detector
Storage Above FACP Smoke Detector
Check
Functional Test
Factory Setting
Measured
Exterior Riser Closet Tamper Switch
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Battery Storage FACP First Power LFP1250 Failed load test
System restored to normal operation: Fail Date: 09/06/2022 Time: 4:00:00 PM
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 09/06/2022
A. Chamizo D. Ijima
6 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
1 Control Panel 1 Annunciator 2 Batteries 2 Smoke Detectors 2 Pull Stations 1 Waterflow 1 Tampers 8 Horn/Strobes 2 Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-Batteries for FACP failed load test and will need to be replaced.
MATERIALS NEEDED:
-(2x) 12V 50Ah Batteries
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220195-1
DATE: 09/06/2022
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B19 2022 FA T&I
10 - SERVICE
IS JOB COMPLETE? No DISC/CREDIT: $0.00
SALES TAX: $0.00
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/06/2022 12:00 PM
Date: 09/06/2022 12:00 PM
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 08/30/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B35
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: LeeRoy Wymer
License No: 200202 Telephone: (907) 854-3770
Manufacturer: King Fisher Monthly
Model Number: KF-APT Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: Edwards Model No: EST 3
Circuit Styles: B, B
Number of Circuits: 4
Software Revision: V5 32
Last Date System Had Any Service Performed: 07/06/20
Last Date that Any Software or Configuration Was Revised: 07/06/2021
1 B Pull Station, Radionics
4 B Smoke Detector, Edwards
10 B Horn/Strobe, Edwards
No. of alarm notification appliance circuits: 3
SIGNALING LINE CIRCUITS
Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1)
Quantity 1 Style(s) B
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): Mechanical Room 107
Disconnecting Means Location: Panel FP, Ckt#1
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 26Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Sealed Lead Acid Leoch DJW12-26Ah 12V 26Ah
Sealed Lead Acid Ultra Tech UT 1270 12V 7Ah
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment Pass
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
UPS Room 103 Duct Detector
Operations Room 109 Pull Station
Operations Room 109 Underfloor 1 Smoke Detector
Operations Room 109 Underfloor 2 Smoke Detector
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
UPS Battery 110 Smoke Detector
UPS Room 103 Smoke Detector
Comments: Four smoke detectors (2 in Operations Room, 1 in Battery Room, and 1 in UPS room) were removed. The devices are not listed in the report since removed. Devices will need to be installed, programmed, and tested.
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Battery Hallway FACP Leoch DJW12-26Ah Failed load test
Battery Hallway FEP Ultra Tech UT 1270 Failed load test
System restored to normal operation: Fail Date: 08/30/2022 Time: 4:00:00 PM
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 08/30/2022
A. Chamizo D. Ijima
6 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
1 Control Panel 1 Expander Panel 2 Batteries 4 Smoke Detectors 1 Duct Detector 1 Pull Stations 10 Horn/Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-Batteries for FACP and FEP failed load test and will need to be replaced.
-Four smoke detectors were missing at locations were plans indicated.
-These four smokes should be above the underfloor smokes and will need to be installed.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
MATERIALS NEEDED:
-(2x) 12V 26Ah -(2x) 12V 7Ah Batteries If not found:
-(4x) SIGA-OSD -(4x) SIGA-SB4
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220202-1
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B35 2022 FA T&I
10 - SERVICE
IS JOB COMPLETE? No DISC/CREDIT: $0.00
SALES TAX: $0.00
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/02/2022 11:42 AM
Employee: Alston Chamizo Date: 09/02/2022 11:42 AM
TERMS AND CONDITIONS
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 08/31/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B38
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: Leeroy Wymer
License No: 220201 Telephone: (907) 854-3770
Manufacturer: King Fisher Monthly
Model Number: KF-APT Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: Edwards Model No: EST 3
Circuit Styles: B, B
Number of Circuits: 5
Software Revision: V5.32
Last Date System Had Any Service Performed: 09/05/17
Last Date that Any Software or Configuration Was Revised: 09/05/2017
6 B Pull Station, Radionics
17 B Smoke Detector, Edwards
1 B Waterflow Switch, Edwards
17 B Horn/Strobe, Edwards
No. of alarm notification appliance circuits: 4
4 B Tamper Switch, Edwards
Quantity 1 Style(s) B
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): Switch Gear Room
Disconnecting Means Location: Panel FP, Ckt#1
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 40Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Sealed Lead Acid Leoch DJW12-26 12V 26Ah
Sealed Lead Acid Ultra Tech UT 1270 12V 7Ah
Sealed Lead Acid Peak PK12V40 12V 40Ah
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment Pass
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Mezzanine Storage Room 201 AHU Duct Detector
Control Room 102 Pull Station
Generator Room 101 Near Fire Protection Room Pull Station
Generator Room 101 Near Rear Exit Pull Station
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Hallway Near Office Pull Station
Switchgear Room 105 Exit Near Smoke 12 Pull Station
Switchgear Room 105 Exit Near Smoke 9 Pull Station
Control Room 102 Breakroom 1 Smoke Detector
Control Room 102 Breakroom 2 Smoke Detector
Control Room 102 Near Control Console 1 Smoke Detector
Control Room 102 Near Control Console 2 Smoke Detector
Switchgear Room 105 1 Smoke Detector
Switchgear Room 105 10 Smoke Detector
Switchgear Room 105 11 Smoke Detector
Switchgear Room 105 12 Smoke Detector
Switchgear Room 105 2 Smoke Detector
Switchgear Room 105 3 Smoke Detector
Switchgear Room 105 5 Smoke Detector
Switchgear Room 105 6 Smoke Detector
Switchgear Room 105 7 Smoke Detector
Switchgear Room 105 8 Smoke Detector
Switchgear Room 105 9 Smoke Detector
Switchgear Room 105 Above FACP Disconnect Smoke Detector
Switchgear Room 105 Near Entrance to Hallway Smoke Detector
Fire Protection Room Fire Sprinkler Riser Waterflow Switch
Fire Protection Room Fire Sprinkler Riser Tamper Switch
Fire Protection Room Low Pressure Tamper Switch
Fire Protection Room Preaction Tamper Tamper Switch
Fire Protection Room Riser Tamper Switch
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Other (Specify)
Battery Control Room 102 FACP Leoch DJW12-26 Failed load test
Battery Control Room 102 FEP Ultra Tech UT 1270 Failed load test
Battery Control Room 102 Preaction Peak PK12V40 Failed load test
System restored to normal operation: Fail Date: 08/31/2022 Time: 4:00:00 PM
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 08/31/2022
A. Chamizo D. Ijima
6 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
2 Control Panel 1 Expander Panel 6 Batteries 17 Smoke Detectors 1 Duct Detector 6 Pull Stations 1 Waterflow 4 Tampers 17 Horn/Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-Batteries for FACP, Preaction Panel, and FEP failed load test and will need to be replaced.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
MATERIALS NEEDED:
-(2x) 12V 40Ah Batteries -(2x) 12V 26Ah Batteries -(2x) 12V 7Ah Batteries
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220201-1
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B38 2022 FA T&I
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/02/2022 09:35 AM
Employee: Alston Chamizo Date: 09/02/2022 09:35 AM
TERMS AND CONDITIONS
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 08/29/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B41
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: Leeroy Wymer
License No: 220200 Telephone: (907) 854-3770
Manufacturer: King Fisher Monthly
Model Number: KF-APT Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: Edwards Model No: EST 3
Circuit Styles: B, B
Number of Circuits: 5
Software Revision: V5.32
Last Date System Had Any Service Performed: 06/30/2017
Last Date that Any Software or Configuration Was Revised: 06/30/2017
4 B Duct Detector, Edwards
5 B Heat Detector, Edwards
3 B Smoke Detector, Edwards
1 B Waterflow Switch, Edwards
18 B Horn/Strobe, Edwards
SIGNALING LINE CIRCUITS
Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1)
Quantity 1 Style(s) B
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): Electrical Room 105
Disconnecting Means Location: Panel FP, Ckt#2
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 26Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Sealed Lead Acid Leoch DJW12-26 12V 26Ah
Sealed Lead Acid Ultra Tech UT 1270 12V 7Ah
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment Pass
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Gym Room 111 Duct Detector
Hallway Near FACP Duct Detector
Mech Room 105 Duct Detector
Substation Room 116 Duct Detector
Gym Storage Room 106 Heat Detector
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Substation Room 116 1 Heat Detector
Substation Room 116 2 Heat Detector
Substation Room 116 3 Heat Detector
Substation Room 116 4 Heat Detector
Gym Room 111 Smoke Detector
Hallway Above FACP Smoke Detector
Room 107 Above FEP Smoke Detector
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Battery Room 107 FACP Battery Cabinet Leoch DJW12-26 Failed load test
Battery Room 107 FEP 1 Ultra Tech UT 1270 Failed load test
System restored to normal operation: Fail Date: 08/29/2022 Time: 4:00:00 PM
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 08/29/2022
A. Chamizo D. Lanuza
7 Hours Each
ACTIONS TAKEN:
Building 41:
-Test and inspected the following devices:
1 Control Panel 1 Expander Panel 4 Batteries 3 Smoke Detectors 4 Duct Detectors 5 Heat Detectors 1 Pull Station 1 Waterflow Switch 18 Horn/Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-Pairs for both the FACP and FEP are over 5 years installed and failed load test.
-When waterflow was tested, the alarm was received but the electronic bell did not activate.
-Bell will need to be replaced and tested.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
MATERIALS NEEDED:
-(2x) 12V 26Ah -(2x) 12V 7Ah -(1x) 24V Bell
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220200-1
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B41 2022 FA T&I
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/02/2022 09:30 AM
Employee: Alston Chamizo Date: 09/02/2022 09:30 AM
TERMS AND CONDITIONS
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 08/25/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B39005
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: LeeRoy Wymer
License No: 220199 Telephone: (907) 854-3770
Manufacturer: King Fisher Monthly
Model Number: KF-APT Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: Other (Specify)
Control Unit Manufacturer: Edwards Model No: EST 3
Circuit Styles: B, B
Number of Circuits: 5
Software Revision: V5.32
Last Date System Had Any Service Performed: 08/25/2022
Last Date that Any Software or Configuration Was Revised: 08/25/2022
3 B Pull Station, Radionics
12 B Smoke Detector, Edwards
7 B Horn/Strobe, Edwards
SIGNALING LINE CIRCUITS
Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1)
Quantity 1 Style(s) B
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): By room 102
Disconnecting Means Location: Panel FP, Ckt#2
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 26Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Sealed Lead Acid Leoch DJM1250 12V 26Ah
Sealed Lead Acid Edwards UT 1272F1 12V 7Ah
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment Pass
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional
Test
Factory
Setting
Measured
Setting Pass Fail
Main Entrance Pull Station
Storage Room 107A Pull Station
Technical Equipment R107 Pull Station
Electrical R105 Smoke Detector
High Smoke 1 Smoke Detector
Check
Functional
Test
Factory
Setting
Measured
Setting Pass Fail
High Smoke 2 Smoke Detector
High Smoke 3 Smoke Detector
High Smoke 4 Smoke Detector
Storage R107 Underfloor Smoke Detector
Storage R107A Underfloor Smoke Detector
Storage Room R105A Smoke Detector
Technical Equipment Underfloor 1 Smoke Detector
Technical Equipment Underfloor 2 Smoke Detector
Technical Equipment R102 Near Entrance Smoke Detector
Technical Equipment R102 Near Toilet Smoke Detector
Comments: Need to replace batteries at FEP 1 to pass test and inspection.
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated
Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Battery Electrical Room R105 FACP Leoch DJM1250 Failed load test
System restored to normal operation: Fail Date: 08/26/2022 Time: 4:00:00 PM
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 08/25/2022
A. Chamizo D. Ijima
7 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
1 Control Panel 1 Annunciator 1 Expander Panel 4 Batteries 12 Smoke Detectors 3 Pull Stations 7 Horn/Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-Batteries for FACP failed load test and will need to be replaced.
-When waterflow was tested, the alarm was received but the electronic bell did not activate.
-Bell will need to be replaced and tested.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
MATERIALS NEEDED:
-(2x) 12V 26Ah Batteries -(1x) 24V Bell
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220199-1
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B39005 2022 FA T&I
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/02/2022 09:16 AM
Employee: Alston Chamizo Date: 09/02/2022 09:16 AM
TERMS AND CONDITIONS
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
Date: 08/26/2022
Name: Phoenix Pacific (Hawaii), Inc. Name: KPST B39009
Address: 2045 Lauwiliwili Street Ste. 101 / Kapolei, HI 96707 Address: Farrington Highway, Makaha, HI 96792
Representative: Alston Chamizo Owner Contact: Leeroy Wymer
License No: 220194 Telephone: (907) 854-3770
Manufacturer: King Fisher Monthly
Model Number: KF-APT Quarterly
Communicator: N/A Semiannually
Manufacturer: N/A Annually
Model Number: N/A Other (Specify)
Control Unit Manufacturer: Edwards Model No: EST 3
Circuit Styles: A
Number of Circuits: 2
Software Revision: V3.7
Last Date System Had Any Service Performed: 07/13/2022
Last Date that Any Software or Configuration Was Revised: 07/13/2022
1 B Aspirating Detector, Xtralis
4 B Heat Detector, Edwards
4 B Pull Station, Edwards
7 B Smoke Detector, Edwards
5 B Horn/Strobe, Edwards
No. of alarm notification appliance circuits: 1
SIGNALING LINE CIRCUITS
Quantity and style of signaling line circuits connected to system (see NFPA 72, Table 6.6.1)
Quantity 1 Style(s) B
SYSTEM POWER SUPPLIES
(a) Primary (Main): Nominal Voltage 120V Amps 20A
Overcurrent Protection: Breaker Amps 20A
Location (of Primary Supply Panelboard): Main Room
Disconnecting Means Location: Panel TP-22
(b) Secondary (Standby): Batteries Storage Battery: Amp-Hr Rating 35Ah
Calculated capacity to operate system, in hours: X 24 60
Engine-driven generator dedicated to fire alarm system: N/A
Sealed Lead Acid AJC DS7(T1) 12V 7Ah
Sealed Lead Acid Full River DC35-12 12V 70Ah
Sealed Lead Acid Ultra Tech UT 12120 12V 12Ah
(c) Emergency or standby system used as a backup to primary power supply, instead of using a secondary power supply:
Monitoring Entity CEO 8:00A
Building Occupants Staff 8:00A
Building Management Leeroy 8:00A
Other (Specify) N/A N/A
AHJ Notified of Any Impairments N/A N/A
SYSTEM TESTS AND INSPECTIONS
TYPE Visual Functional Comments
Control Unit Pass
Interface Equipment Pass
Lamps/LEDS Pass
Fuses Pass
Primary Power Supply Pass
Trouble Signals Pass
Disconnect Switches Pass
Ground Fault Monitoring Pass
SECONDARY POWER
NOTIFICATION APPLIANCES
Audible Pass
Visible Pass
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Comm Room Aspirating Detector
Generator Room Above Generator Heat Detector
Generator Room Closer to Pull Station Heat Detector
Vehicle Bay Near Entrance Heat Detector
Check
Functional Test
Factory Setting
Measured Setting Pass Fail
Vehicle Bay Near Exit Heat Detector
Generator Room Pull Station
Main Entrance Pull Station
Outside Vehicle Bay Pull Station
Vehicle Bay Pull Station
Antenna Pedestal Smoke Detector
Main Entrance Air Lock Smoke Detector
High Above Sky Crane Smoke Detector
High Above Stair to Catwalk Smoke Detector
High Left of Vehicle Bay Smoke Detector
High Main Entrance Above FACP Smoke Detector
High Right of Vehicle Bay Smoke Detector
Comments: Alarm could not be silenced on alarm silence possibly due to a second active alarm. VESDA unit FIRE 1 alarm on the panel does not activate the alarm.
Phone Jacks N/A
Off-Hook Indicator N/A
Amplifier(s) N/A
Type Generator(s) N/A
Operation
Simulated Operation Time & Date
N/A N/A N/A N/A N/A
SPECIAL HAZARD SYSTEMS
N/A N/A N/A N/A N/A
Special Procedures: N/A
Comments: N/A
SUPERVISING STATION MONITORING Yes No Time Comments
Alarm Signal N/A N/A
Alarm Restoration N/A N/A
Trouble Signal N/A N/A
Monitoring Agency CEO 4:00P
Building Occupants Staff 4:00P
Battery FACP Near Main Entrance AJC DS7(T1) Failed load test
System restored to normal operation: Fail Date: 08/26/2022 Time: 4:00:00 PM
Name of Inspector: Alston Chamizo Date: Time:
Signature:
WORK PERFORMED: 08/26/2022
A. Chamizo D. Ijima
8 Hours Each
ACTIONS TAKEN:
-Test and inspected the following devices:
1 Control Panel 1 Annunciator 1 Expander Panel 6 Batteries 7 Smoke Detectors 4 Heat Detectors 4 Pull Stations 5 Horn/Strobes
-Verified messages on activations.
-Labelled and scanned each device for Building Reports.
-Batteries for FACP failed load test and will need to be replaced.
-When waterflow was tested, the alarm was received but the electronic bell did not activate.
-Bell will need to be replaced and tested.
FOLLOW UP ACTIONS:
-Continue with the scheduled test and inspection.
MATERIALS NEEDED:
-(2x) 12V 7Ah Batteries -(1x) 24V Bell
2045 Lauwiliwili St., Unit 101, Kapolei, HI 96707 Main: (808) 682-1000 info@phoenixpacificinc.com www.phoenixpacificinc.com
JOB WORK ORDER
ORDER #:
220194-1
CLIENT LOCATION: KAENA POINT SATELLIT TRACKING
Kaena Point Farrington Hwy Makaha , HI 96792
BILLED TO:
KAENA POINT SATELLIT TRACKING
P.O. BOX 868
WAIANAE , HI 96792-0868
KAENA POINT SATELLITE TRACKING - B39009 2022 FA T&I
TAXABLE: $0.00
NON-TAXABLE: $0.00
DISCOUNT: $0.00
BALANCE $0.00
NET DUE: $0.00
Customer:
Date: 09/02/2022 09:22 AM
Employee: Alston Chamizo Date: 09/02/2022 09:22 AM
TERMS AND CONDITIONS
I / We hereby authorize the above work to be done along with the necessary materials and grant Phoenix Pacific, Inc., or its employees permission to test and/or operate the unit to be worked on. An express mechanic's lien is hereby acknowledged to secure payment for the work performed. Payment is due upon completion of work if no prior arrangement has been cleared by Phoenix Pacific, Inc., for credit. I / We agree to pay later fees at the rate of 1-1/2% per month on all accounts
| Bldg 10 - FA testing - Sep 2022 |
| KPST-B10 |
| 220247-1 - Job Work Order_3 |
| Building 8 - FA testing - Aug 2022 |
| KPST-B8 |
| 220198-1 - Job Work Order |
| Building 9 - FA testing - Aug 2022 |
| KPST-B9 |
| 220197-1 - Job Work Order_2 |
| Building 13 - FA testing - Sep 2022 |
| KPST-B13 |
| 220196-1 - Job Work Order |
| Building 19 - FA testing - Sep 2022 |
| KPST-B19 |
| 220195-1 - Job Work Order |
| Building 35 - FA testing - Aug 2022 |
| KPST-B35 |
| 220202-1 - Job Work Order |
| Building 38 - FA testing - Aug 2022 |
| KPST-B38 |
| 220201-1 - Job Work Order |
This is the start of the file's text. The full file is on GovTribe.